MODEL G310C2/R2/S2 - 10.4" COLOR TOUCHSCREEN  
CONFIGURED USING CRIMSON® SOFTWARE (VERSION 2.0 OR  
LATER)  
UP TO 5 RS-232/422/485 COMMUNICATIONS PORTS  
(2 RS-232 AND 1 RS-422/485 ON BOARD, 1 RS-232 AND 1 RS-422/485  
ON OPTIONAL COMMUNICATIONS CARD)  
10 BASE T/100 BASE-TX ETHERNET PORT TO NETWORK UNITS  
AND HOST WEB PAGES (2ND ETHERNET PORT OPTIONAL)  
USB PORT TO DOWNLOAD THE UNIT’S CONFIGURATION FROM A  
PC OR FOR DATA TRANSFERS TO A PC  
UNIT’S CONFIGURATION IS STORED IN NON-VOLATILE MEMORY  
(32MBYTE FLASH)  
COMPACTFLASH® SOCKET TO INCREASE MEMORY CAPACITY  
10.4-INCH TFT 32K VGA 640X480 PIXEL LCD OR SVGA 800X600 LCD  
OUTDOOR UNIT WITH UV RATED OVERLAY AVAILABLE  
8-BUTTON KEYPAD FOR ON-SCREEN MENUS  
THREE FRONT PANEL LEDS  
FOR USE IN HAZARDOUS LOCATIONS:  
Class I, Division 2, Groups A, B, C, and D  
U
POWER UNIT FROM 24VDC ±20% SUPPLY  
R
C L US LISTED  
43NH  
RESISTIVE ANALOG TOUCHSCREEN  
PROCESS CONTROL EQUIPMENT  
GENERAL DESCRIPTION  
ORDERING INFORMATION  
The G310 Operator Interface Terminal combines unique capabilities normally  
expected from high-end units with a very affordable price. It is built around a  
high performance core with integrated functionality. This core allows the G310  
to perform many of the normal features of the Paradigm range of Operator  
Interfaces while improving and adding new features.  
MODEL NO.  
DESCRIPTION  
PART NUMBER  
10.4" TFT VGA Display Operator Interface (indoor),  
USB Host, Isolated Comms  
G310C210  
10.4" TFT VGA Display Operator Interface (indoor),  
Dual Ethernet, USB Host, Isolated Comms  
G310C230  
G310R210  
G310R230  
G310S210  
The G310 is able to communicate with many different types of hardware using  
high-speed RS232/422/485 communications ports and Ethernet 10 Base T/100  
Base-TX communications. In addition, the G310 features USB for fast downloads  
of configuration files and access to trending and data logging. A CompactFlash  
socket is provided so that Flash cards can be used to collect your trending and data  
logging information as well as to store larger configuration files.  
In addition to accessing and controlling of external resources, the G310  
allows a user to easily view and enter information. Users can enter data through  
the touchscreen or front panel 8-button keypad.  
10.4" TFT SVGA Display Operator Interface (indoor),  
USB Host, Isolated Comms  
G310  
10.4" TFT SVGA Display Operator Interface (indoor),  
Dual Ethernet, USB Host, Isolated Comms  
10.4" TFT VGA Display Operator Interface (indoor or  
outdoor), Glossy Finish, USB Host, Isolated Comms 7  
10.4" TFT VGA Display Operator Interface (indoor or  
outdoor), Glossy Finish, Dual Ethernet, USB Host,  
Isolated Comms 7  
G310S230  
G3CF  
G3RS  
G3CN  
G3DN  
CompactFlash Card 6  
G3CFxxxx  
G3RS0000  
G3CN0000  
G3DN0000  
G3GSM000  
G3PBDP00  
SFCRM  
CONTENTS OF PACKAGE  
- G310 Operator Interface.  
- Panel Gasket.  
- This hardware bulletin.  
- Template for panel cutout.  
RS 232/485 Optional Communication Card  
CANopen Optional Communication Card  
DeviceNet Optional Communication Card  
G3GSM GSM/GPRS Modem Option Card 3  
G3PBDP Profibus DP Optional Communication Card  
SFCRM Crimson 2  
- Hardware packet for mounting unit into panel.  
- Terminal block for connecting power.  
SAFETY SUMMARY  
RS-232 Programming Cable  
CBLPROG0  
CBLUSB00  
CBLxxxxx  
DRxxxxxx  
BNL20000  
G3FILM10  
All safety related regulations, local codes and instructions that appear in the  
manual or on equipment must be observed to ensure personal safety and to  
prevent damage to either the instrument or equipment connected to it. If  
equipment is used in a manner not specified by the manufacturer, the protection  
provided by the equipment may be impaired.  
CBL  
DR  
USB Cable  
Communications Cables 1  
DIN Rail Mountable Adapter Products 4  
Replacement Battery 5  
Do not use the controller to directly command motors, valves, or other  
actuators not equipped with safeguards. To do so can be potentially harmful to  
persons or equipment in the event of a fault to the controller.  
G3FILM Protective Films  
1 Contact your Red Lion distributor or visit our website for complete selection.  
2
Use this part number to purchase Crimson on CD with a printed manual, USB  
cable, and RS-232 cable. Otherwise, download for free from www.redlion.net.  
Antenna (G3QANT00) is NOT included with the card. Must be purchased  
separately if needed.  
4 Red Lion offers RJ modular jack adapters. Refer to the DR literature for complete  
WARNING - EXPLOSION HAZARD - SUBSTITUTION  
OF ANY COMPONENT MAY IMPAIR SUITABILITY  
FOR CLASS I, DIVISION 2  
3
details.  
5 Battery type is lithium coin type CR2025  
Industrial grade two million write cycles. SMART Modular Technologies model  
SG9CF (UL Listed Directory Category NWGQ).  
7 LED backlight may not be field replaceable. Consult factory.  
CAUTION: Risk of Danger.  
Read complete instructions prior to  
installation and operation of the unit.  
6
CompactFlash is a registered trademark of CompactFlash Association.  
1
SpecificationS  
1. POWER REQUIREMENTS:  
Ethernet Ports: 10 BASE-T / 100 BASE-TX  
RJ45 jack is wired as a NIC (Network Interface Card). The jack shield is  
electrically connected to Earth ground.  
A secondary ethernet port (with its own Mac ID) is available as an option.  
8. ENVIRONMENTAL CONDITIONS:  
Must use a Class 2 circuit according to National Electrical Code (NEC),  
NFPA-70 or Canadian Electrical Code (CEC), Part I, C22.1 or a Limited  
Power Supply (LPS) according to IEC 60950-1 or Limited-energy circuit  
according to IEC 61010-1.  
Power connection via removable three position terminal block.  
Operating Temperature Range: 0 to 50°C  
Storage Temperature Range: -20 to 70°C  
Operating and Storage Humidity: 80% maximum relative humidity (non-  
condensing) from 0 to 50°C.  
Vibration to IEC 68-2-6: Operational 5 to 150 Hz, 2 g.  
Shock to IEC 68-2-27: Operational 35 g.  
Altitude: Up to 2000 meters.  
9. CERTIFICATIONS AND COMPLIANCES:  
CE Approved  
EN 61326-1 Immunity to Industrial Locations  
Emission CISPR 11 Class A  
Safety requirements for electrical equipment for measurement, control, and  
laboratory use:  
EN 61010-1: General Requirements  
RoHS Compliant  
UL Listed: File #E179259  
UL Hazardous: File #E245515  
Type 4X Enclosure rating (Face only)  
IP66 Enclosure rating (Face only)  
10. CONNECTIONS: Compression cage-clamp terminal block.  
Wire Gage: 12-30 AWG copper wire  
Torque: 5-7 inch-pounds (56-79 N-cm)  
11. CONSTRUCTION: Steel rear metal enclosure with NEMA 4X/IP66  
aluminum front plate when correctly fitted with the gasket provided.  
Installation Category II, Pollution Degree 2.  
12. MOUNTING REQUIREMENTS: Maximum panel thickness is 0.25" (6.3  
mm). For NEMA 4X/IP66 sealing, a steel panel with a minimum thickness of  
0.125" (3.17 mm) is recommended.  
Supply Voltage:  
+24 VDC ±20%  
G310C/R  
G310S  
Typical Power:  
Maximum Power:  
16 W  
25 W  
16 W  
26 W  
Note:  
1. The G310s circuit common is not connected to the enclosure of the  
unit. See “Connecting to Earth Ground” in the section “Installing and  
Powering the G310.”  
2. BATTERY: Lithium coin cell CR2025. Typical lifetime of 10 years.  
3. LCD MODULE DISPLAYS:  
MODEL  
G310C2  
G310R2  
G310S2  
SIZE  
10.4-inch  
10.4-inch  
10.4-inch  
TYPE  
TFT  
TFT  
TFT  
COLORS  
PIXELS  
BRIGHTNESS  
32K  
640 X 480  
450 cd/m2  
32K  
800 X 600  
400 cd/m2  
32K  
640 X 480  
1000 cd/m2  
BACKLIGHT LIFETIME * 70,000 HR typ. 70,000 HR typ. 50,000 HR typ.  
BACKLIGHT TYPE LED LED LED  
* Lifetime at room temperature. Refer to “Display” in the “Software/Unit  
Operation” section.  
4. 8-KEY KEYPAD: for on-screen menus.  
5. TOUCHSCREEN: Resistive analog  
6. MEMORY:  
On Board User Memory: 32 Mbyte of onboard non-volatile Flash memory.  
Memory Card: CompactFlash Type II slot for Type I and Type II  
CompactFlash cards.  
7. COMMUNICATIONS:  
USB Port: Adheres to USB 2.0 specification full speed only via Type B  
connection.  
Maximum Mounting Stud Torque: 17 inch-pounds (1.92 N-m)  
13. WEIGHT: 5.44 lbs (2.47 Kg)  
WARNING - DO NOT CONNECT OR DISCONNECT CABLES  
WHILE POWER IS APPLIED UNLESS AREA IS KNOWN TO BE  
NON-HAZARDOUS. USB PORT IS FOR SYSTEM SET-UP AND  
DIAGNOSTICS AND IS NOT INTENDED FOR PERMANENT  
CONNECTION.  
USB Host Ports: Comply with Universal Serial Bus Specification Rev 2.0.  
Support data transfers at full-speed. Hardware over current protected (0.5  
A max per port).  
Serial Ports: Ports are individually isolated. Format and Baud Rates for each  
port are individually software programmable up to 115,200 baud.  
PGM Port: RS232 port via RJ12.  
COMMS Ports: RS422/485 port via RJ45, and RS232 port via RJ12.  
DH485 TXEN: Transmit enable; open collector, VOH = 15 VDC,  
VOL = 0.5 V @ 25 mA max.  
Note: For additional information on the communications or signal  
common and connections to earth ground please see the “Connecting to  
Earth Ground” in the section “Installing and Powering the G310.”  
DIMENSIONS In inches (mm)  
12.83 (325.8)  
2.45 (62)  
11.25 (285.8)  
9.50  
8.25  
(209.4)  
(241.3)  
2
inStalling and powering the g310  
MOUNTING INSTRUCTIONS  
CONNECTING TO EARTH GROUND  
This operator interface is designed for through-panel mounting. A panel cut-  
out diagram and a template are provided. Care should be taken to remove any  
loose material from the mounting cut-out to prevent that material from falling  
into the operator interface during installation. A gasket is provided to enable  
sealing to NEMA 4X/IP66 specification. Install the 14 kep nuts provided and  
tighten evenly for uniform gasket compression.  
The chassis ground is not connected to signal common of the unit.  
Maintaining isolation between earth ground and signal common is not required  
to operate your unit. But, other equipment connected to this unit may require  
isolation between signal common and earth ground. To maintain isolation  
between signal common and earth ground care must be taken when connections  
are made to the unit. For example, a power supply with isolation between its  
signal common and earth ground must be used. Also, plugging in a USB cable  
may connect signal common and earth ground.1  
Note: Tightening the kep nuts beyond a maximum of 17 inch-pounds (1.92  
N-m) may cause damage to the front panel.  
1. USB’s shield may be connected to earth ground at the host. USB’s shield  
in turn may also be connected to signal common.  
12.25 (311.2)  
11.725 (297.8)  
6.125 (155.6)  
14X .188 (4.8)  
POWER SUPPLY REQUIREMENTS  
The units require a 24 VDC power supply rated at 26 W. Your unit may draw  
considerably less than the rated power depending upon the options being used.  
As additional features are used your unit will draw increasing amounts of power.  
Items that could cause increases in current are additional communications,  
optional communications card, CompactFlash card, and other features  
programmed through Crimson.  
8.40  
(213.4)  
2.975  
(75.6)  
In any case, it is very important that the power supply is mounted correctly if  
the unit is to operate reliably. Please take care to observe the following points:  
– The power supply must be mounted close to the unit, with usually not  
more than 6 feet (1.8 m) of cable between the supply and the operator  
interface. Ideally, the shortest length possible should be used.  
8.925  
(226.7)  
– The wire used to connect the operator interface’s power supply should  
be at least 22-gage wire. If a longer cable run is used, a heavier gage  
wire should be used. The routing of the cable should be kept away from  
large contactors, inverters, and other devices which may generate  
significant electrical noise.  
All tolerances ±0.010" (±0.25 mm).  
– A power supply with an NEC Class 2 or Limited Power Source (LPS)  
and SELV rating is to be used. This type of power supply provides  
isolation to accessible circuits from hazardous voltage levels generated  
by a mains power supply due to single faults. SELV is an acronym for  
“safety extra-low voltage.” Safety extra-low voltage circuits shall  
exhibit voltages safe to touch both under normal operating conditions  
and after a single fault, such as a breakdown of a layer of basic  
insulation or after the failure of a single component has occurred.  
ALL NONINCENDIVE CIRCUITS MUST BE WIRED USING  
DIVISION 2 WIRING METHODS AS SPECIFIED IN THE NATIONAL  
ELECTRICAL CODE, NFPA 70 FOR INSTALLATION WITHIN THE  
UNITED STATES, OR AS SPECIFIED IN THE CANADIAN  
ELECTRICAL CODE FOR INSTALLATION IN CANADA.  
WARNING - EXPLOSION HAZARD - DO NOT DISCONNECT  
EQUIPMENT WHILE THE CIRCUIT IS LIVE OR UNLESS THE AREA  
IS KNOWN TO BE FREE OF IGNITABLE CONCENTRATIONS.  
inStalling an option card  
WARNING - EXPLOSION HAZARD - DO NOT DISCONNECT  
EQUIPMENT UNLESS POWER HAS BEEN DISCONNECTED  
AND THE AREA IS KNOWN TO BE NON-HAZARDOUS.  
Each option card comes with a cable for communications and three  
screws for attaching the option card to the G3’s main board.  
To install the option card, remove all power and I/O communications  
cables from the unit and remove the rear cover. Connect the cable from the  
option card to the connector on the main board. Be sure both ends of the  
cable are firmly seated into their appropriate connector housings. Use the  
three screws provided to mount the option card to the main board as shown  
in Figure 1.  
Carefully replace the rear cover by reversing the instructions for  
removing the rear cover.  
TYPICAL EXPANSION CARD INSTALLATION  
Figure 1  
3
communicating with the g310  
CONFIGURING A G310  
CABLES AND DRIVERS  
The G310 is configured using Crimson software. Crimson is available as a free  
download from Red Lion’s website, or it can be purchased on CD. Updates to  
Crimson for new features and drivers are posted on the website as they become  
available. By configuring the G310 using the latest version of Crimson, you are  
assured that your unit has the most up to date feature set. Crimson software can  
configure the G310 through the RS232 PGM port, USB port, or CompactFlash.  
The USB port is connected using a standard USB cable with a Type B  
connector. The driver needed to use the USB port will be installed with Crimson.  
If this driver has not been installed, it can be downloaded from the website.  
The RS232 PGM port uses a programming cable made by Red Lion to  
connect to the DB9 COM port of your computer. If you choose to make your  
own cable, use the “G310 Port Pin Out Diagram” for wiring information.  
The CompactFlash can be used to program a G3 by placing a configuration  
file and firmware on the CompactFlash card. The card is then inserted into the  
target G3 and powered. Refer to the Crimson literature for more information on  
the proper names and locations of the files.  
Red Lion has a wide range of cables and drivers for use with many different  
communication types. A list of these drivers and cables along with pin outs is  
available from Red Lion’s website. New cables and drivers are added on a  
regular basis. If making your own cable, refer to the “G310 Port Pin Outs” for  
wiring information.  
ETHERNET COMMUNICATIONS  
Ethernet communications can be established at either 10 BASE-T or 100  
BASE-TX. The G310 unit’s RJ45 jack is wired as a NIC (Network Interface  
Card). For example, when wiring to a hub or switch use a straight-through cable,  
but when connecting to another NIC use a crossover cable.  
LED COLOR  
YELLOW solid  
YELLOW flashing  
GREEN  
DESCRIPTION  
Link established.  
Data being transferred.  
10 BASE-T Communications  
100 BASE-TX Communications  
AMBER  
ACCESSING THE COMPACTFLASH CARD  
The Ethernet connector contains two LEDs. A yellow LED in the upper right,  
and a bi-color green/amber LED in the upper left. The LEDs represent the  
following statuses.  
The Crimson manual contains additional information on Ethernet  
communications.  
VIA USB DEVICE PORT  
In order to access data from the CompactFlash card via the USB device port,  
a driver must be installed on your computer. This driver is installed with  
Crimson and is located in the folder C:\Program Files\Red Lion Controls\  
Crimson 2.0\Device\ after Crimson is installed. This may have already been  
accomplished if your G310 was configured using the USB port.  
Once the driver is installed, connect the G310 to your PC with a USB cable,  
and follow the “Mounting the CompactFlash” instructions found in the Crimson  
user manual.  
RS232 PORTS  
The G310 has two individually isolated RS232 ports. There is the PGM port  
and the COMMS port. Although only one of these ports can be used for  
programming, both ports can be used for communications with a PLC.  
The RS232 PGM port can be used for either master or slave protocols with  
any G310 configuration.  
WARNING - DO NOT CONNECT OR DISCONNECT CABLES  
WHILE POWER IS APPLIED UNLESS AREA IS KNOWN TO BE  
NON-HAZARDOUS. USB PORT IS FOR SYSTEM SET-UP AND  
DIAGNOSTICS AND IS NOT INTENDED FOR PERMANENT  
CONNECTION.  
G310 PORT PIN OUTS  
RS485  
RS232  
RS232  
1
2 3 4  
COMMS  
PORT  
COMMS  
PORT  
PGM PORT  
USB HOST  
PROTECTIVE  
EARTH GROUND  
ETHERNET  
(NIC)  
AUXILIARY  
ETHERNET  
(OPTIONAL)  
USB  
TYPE B  
POWER  
CONNECTOR  
4
Examples of RS232 communications could involve another Red Lion  
product or a PC. By using a cable with RJ12 ends on it, and a twist in the cable,  
RS232 communications with another G3 product or the Modular Controller can  
be established. Red Lion part numbers for cables with a twist in them are  
CBLPROG0 1, CBLRLC01 2, or CBLRC02 3.  
Examples of RS485 2-Wire Connections  
G3 to Red Lion RJ11 (CBLRLC00)  
DLC, IAMS, ITMS, PAXCDC4C  
Connections  
G3 RS232 to a PC  
G3: RJ45  
Name  
TxEN  
COMM  
TxB  
RLC: RJ11  
Name  
TxEN  
COMM  
B-  
Connections  
5
6
1
2
2
3
5
4
G3: RJ12  
Name  
COMM  
Tx  
PC: DB9  
Name  
DCD  
Rx  
4
5
2
1
2
3
4
5
6
7
8
9
TxA  
A+  
Rx  
Tx  
N/C  
DTR  
GND  
DSR  
RTS  
CTS  
RI  
G3 to Modular Controller (CBLRLC05)  
3
COMM  
N/C  
Connections  
G3  
1,4  
4,1  
2,3  
3,2  
5
Name  
TxB  
Modular Controller  
Name  
TxB  
1
6
CTS  
RTS  
N/C  
1,4  
4,1  
2,3  
3,2  
5
RxB  
RxB  
TxA  
TxA  
RxA  
RxA  
ICM5  
CONNECTING A G310 OPERATOR  
INTERFACE TO AN ICM5  
TxEN  
COMM  
TxB  
TxEN  
COMM  
TxB  
6
6
7
7
8
TxA  
8
TxA  
DH485 COMMUNICATIONS  
The G310’s RS422/485 COMMS port can also be used for Allen Bradley  
DH485 communications.  
CBLPROG0  
WARNING: DO NOT use a standard DH485 cable to connect this port to  
Allen Bradley equipment. A cable and wiring diagram are available from  
Red Lion.  
ICM5 DIP Switch Settings  
G3 to AB SLC 500 (CBLAB003)  
Connections  
RJ45: RLC  
Name  
TxB  
RJ45: A-B  
Name  
A
1
2
1
2
-
TxA  
B
Application Dependent  
3, 8  
4, 7  
5
RxA  
24V  
RxB  
-
COMM  
TxEN  
SHIELD  
COMM  
24V  
1 CBLPROG0 can also be used to communicate with either a PC or an ICM5.  
2 DB9 adapter not included, 1 foot long.  
3 DB9 adapter not included, 10 feet long.  
TxEN  
COMM  
TxB  
5
4
-
6
4, 7  
3, 8  
TxA  
-
RS422/485 COMMS PORT  
The G310 has one isolated RS422/485 port. This port can be configured to  
act as either RS422 or RS485.  
POWER SUPPLY ISOLATION BLOCK DIAGRAM  
RS422/485 4-WIRE  
CONNECTIONS  
RS485 2-WIRE  
CONNECTIONS  
+
-
POWER  
SUPPLY  
USB DEVICE  
PROGRAMMING  
24VDC  
5V  
A
130K  
130K  
7
5V  
TxB  
TxA  
A
1
130K  
130K  
7
TX  
ISOLATED  
ISOLATED  
TxB  
TxA  
8
2
1
RS232  
PORT A  
PGM PORT  
RS485  
PORT A  
HOST A  
A
TX/RX  
8
2
B
C
5
TxEN (OC)  
ISOLATED  
5
6
TxEN (OC)  
GND  
RS232  
PORT B  
HOST B  
A
5V  
130K  
130K  
D
4
3
RxB  
RxA  
RX  
ISOLATED  
ETHERNET  
ISOLATED  
AUXILIARY  
ETHERNET  
6
GND  
E
F
Note: All Red Lion devices connect A to A and B to B, except for Paradigm  
devices. Refer to www.redlion.net for additional information.  
5
Software/unit operation  
CRIMSON SOFTWARE  
KEYPAD  
Crimson software is available as a free download from Red Lion’s website or  
it can be purchased on a CD, see “Ordering Information” for part number. The  
latest version of the software is always available from the website, and updating  
your copy is free.  
The G310 keypad consists of eight keys for on-screen menus.  
TOUCHSCREEN  
This operator interface utilizes a resistive analog touchscreen for user input.  
The unit will only produce an audible tone (beep) when a touch on an active  
touchscreen cell in sensed. The touchscreen is fully functional as soon as the  
operator interface is initialized, and can be operated with gloved hands.  
DISPLAY  
This operator interface uses a liquid crystal display (LCD) for displaying text  
and graphics. The backlight can be dimmed for low light conditions.  
Display backlights have a limited lifetime. Backlight lifetime is based upon  
the amount of time the display is turned on at full intensity. Turning the  
backlight off when the display is not in use can extend the lifetime of your  
backlight. This can be accomplished through the Crimson software when  
configuring your unit.  
TROUBLESHOOTING YOUR G310  
If for any reason you have trouble operating, connecting, or simply have  
questions concerning your new G310, contact Red Lion’s technical support.  
For contact information, refer to the back page of this bulletin for phone and  
fax numbers.  
BACKLIGHT REPLACEMENT  
G310S2 LED Backlight  
EMAIL: techsupport@redlion.net  
Web Site: http://www.redlion.net  
The LED backlight is not field replaceable. Unit must be returned  
to Red Lion Controls for repair.  
G310C2/R2 LED Backlight  
The LED backlight is field replaceable in non-hazardous  
locations only. Refer to the instructions included in the backlight  
replacement kit. Contact Red Lion Controls for the appropriate  
part number.  
FRONT PANEL LEDS  
There are three front panel LEDs. Shown below is the default status of  
the LEDs.  
LED  
INDICATION  
RED (TOP, LABELED “PWR”)  
FLASHING Unit is in the boot loader, no valid configuration is loaded.1  
STEADY  
YELLOW (MIDDLE)  
Unit is powered and running an application.  
OFF  
No CompactFlash card is present.  
STEADY  
Valid CompactFlash card present.  
FLASHING  
RAPIDLY  
CompactFlash card being checked.  
Unit is writing to the CompactFlash, either because it is storing  
FLICKERING data, or because the PC connected via the USB port has  
locked the drive.2  
FLASHING  
Incorrectly formatted CompactFlash card present.  
SLOWLY  
GREEN (BOTTOM)  
FLASHING A tag is in an alarm state.  
STEADY  
Valid configuration is loaded and there are no alarms present.  
1. The operator interface is shipped without a configuration. After  
downloading a configuration, if the light remains in the flashing state  
continuously, try cycling power. If the LED still continues to flash, try  
downloading a configuration again.  
2. Do not turn off power to the unit while this light is flickering. The unit  
writes data in two minute intervals. Later Microsoft operating systems will  
not lock the drive unless they need to write data; Windows 98 may lock  
the drive any time it is mounted, thereby interfering with logging. Refer  
to “Mounting the CompactFlash” in the Crimson User Manual.  
6
BATTERY & TIME KEEPING  
WARNING - EXPLOSION HAZARD - THE AREA MUST BE KNOWN  
TO BE NON-HAZARDOUS BEFORE SERVICING/ REPLACING  
THE UNIT AND BEFORE INSTALLING OR REMOVING I/O WIRING  
AND BATTERY.  
WARNING - EXPLOSION HAZARD - DO NOT DISCONNECT  
EQUIPMENT UNLESS POWER HAS BEEN DISCONNECTED  
AND THE AREA IS KNOWN TO BE NON-HAZARDOUS.  
A battery is used to keep time when the unit is without power. Typical  
accuracy of the G310 time keeping is less than one minute per month drift. The  
battery of a G310 unit does not affect the unit’s memory, all configurations and  
data is stored in non-volatile memory.  
BATTERY  
CAUTION: The circuit board contains static sensitive  
components. Before handling the operator interface without the  
rear cover attached, discharge static charges from your body by  
touching a grounded bare metal object. Ideally, handle the  
operator interface at a static controlled clean workstation. Also,  
do not touch the surface areas of the circuit board. Dirt, oil, or  
other contaminants may adversely affect circuit operation.  
To change the battery of a G310, remove power, cabling, and then the rear  
cover of the unit. To remove the cover, remove the five screws designated by the  
arrows on the rear of the unit. Then, by lifting the top side, hinge the cover, thus  
providing clearance for the connectors on the bottom side of the PCB as shown  
in the illustration below. Install in the reverse manner.  
Remove the old battery* from the holder and replace with the new battery.  
Replace the rear cover, cables, and re-apply power. Using Crimson or the unit’s  
keypad, enter the correct time and date.  
WARNING - EXPLOSION HAZARD -  
BATTERIES MUST ONLY BE CHANGED IN AN  
AREA KNOWN TO BE NON-HAZARDOUS.  
* Please note that the old battery must be disposed of in a manner that  
complies with your local waste regulations. Also, the battery must not be  
disposed of in fire, or in a manner whereby it may be damaged and its contents  
come into contact with human skin.  
The battery used by the G310 is a lithium type CR2025.  
7
optional featureS and acceSSorieS  
INDOOR VERSUS OUTDOOR  
COMPACTFLASH SOCKET  
The G310C2x0 and the G310R2x0 use an overlay with a textured finish and  
keys that are embossed. This overlay is not rated for outdoor use.  
The G310S2x0 uses an overlay with a glossy finish that uses a UV rated  
material for outdoor use. The keys on this overlay are not embossed. The display  
is significantly brighter than the G310C2x0.  
CompactFlash socket is a Type II socket that can accept either Type I or II  
cards. Use cards with a minimum of 4 Mbytes and formatted to a maximum of  
2 Gbytes (see Note box below) with the G310’s CompactFlash socket. Cards  
are available at most computer and office supply retailers.  
CompactFlash can be used for configuration transfers, larger configurations,  
data logging, and trending.  
OPTIONAL COMMUNICATION CARD  
Red Lion offers optional communication cards for fieldbus communications.  
These communication cards will allow your G310 to communicate with many  
of the popular fieldbus protocols.  
Red Lion is also offering a communications card for additional RS232 and  
RS422/485 communications. Visit Red Lion’s website for information and  
availability of these cards.  
Note: Do not remove or insert  
the CompactFlash card while  
power is applied. Refer to  
“Front Panel LEDs.”  
CUSTOM LOGO  
CompactFlash  
(Top Side)  
Each G3 operator interface has an embossed area containing the Red Lion  
logo. Red Lion can provide custom logos to apply to this area. Contact your  
distributor for additional information and pricing.  
CompactFlash-  
Insert Face Up  
.51 (13)  
Information stored on a CompactFlash card by a G310 can be read by a card  
reader attached to a PC. This information is stored in IBM (Windows®) PC  
compatible FAT16 file format.  
FRONT OVERLAY  
1.65 (42)  
NOTE  
For reliable operation of this and other Red Lion products, one of the  
following brands of CompactFlash card must be used...  
SimpleTech  
SanDisk®  
SMART® Modular  
Silicon Systems  
swissbit®  
Not all of the above manufacturers offer CompactFlash cards recognized to  
UL standards, which may be required for your application.  
Although RLC products limit use of CompactFlash card memory to 2 GB,  
cards with a larger capacity can be used. They MUST be formatted to 2  
GB and use the FAT 16 file system. It is recommended to format the CF  
card using the format utility from within Crimson.  
LIMITED WARRANTY  
The Company warrants the products it manufactures against defects in materials and workmanship for a period limited to two  
years from the date of shipment, provided the products have been stored, handled, installed, and used under proper conditions.  
The Company’s liability under this limited warranty shall extend only to the repair or replacement of a defective product, at The  
Company’s option. The Company disclaims all liability for any affirmation, promise or representation with respect to the  
products.  
The customer agrees to hold Red Lion Controls harmless from, defend, and indemnify RLC against damages, claims, and  
expenses arising out of subsequent sales of RLC products or products containing components manufactured by RLC and based  
upon personal injuries, deaths, property damage, lost profits, and other matters which Buyer, its employees, or sub-contractors  
are or may be to any extent liable, including without limitation penalties imposed by the Consumer Product Safety Act (P.L.  
92-573) and liability imposed upon any person pursuant to the Magnuson-Moss Warranty Act (P.L. 93-637), as now in effect or  
as amended hereafter.  
No warranties expressed or implied are created with respect to The Company’s products except those expressly contained herein.  
The Customer acknowledges the disclaimers and limitations contained herein and relies on no other warranties or affirmations.  
Red Lion Controls  
China  
Red Lion Controls  
Headquarters  
20 Willow Springs Circle  
York PA 17406  
Tel +1 (717) 767-6511  
Fax +1 (717) 764-0839  
Red Lion Controls  
Europe  
Softwareweg 9  
Red Lion Controls  
India  
201-B, 2nd Floor, Park Centra  
Opp 32 Mile Stone, Sector-30  
Gurgaon-122002 Haryana, India  
Tel +91 984 487 0503  
Unit 1102, XinMao Plaza  
Building 9, No.99 Tianzhou Road  
ShangHai, P.R. China 200223  
Tel +86 21 6113 3688  
Fax +86 21 6113 3683  
NL - 3821 BN Amersfoort  
Tel +31 (0) 334 723 225  
Fax +31 (0) 334 893 793  

相关型号:

G310C230

10.4" COLOR TOUCHSCREEN
REDLION

G311

Multipurpose Enclosures
ETC

G313

Multipurpose Enclosures
ETC

G317

Multipurpose Enclosures
ETC

G31K0C-P03LPH0-0000

CONN RCPT FMALE 3POS GOLD SOLDER
ETC

G31K0C-P07LFG0-0000

CONN RCPT FMALE 7POS GOLD SOLDER
ETC

G31K0C-P10LCC0-0000

CONN RCPT FMALE 10POS GOLD SOLDR
ETC

G31K0C-P16LCC0-0000

CONN RCPT FMALE 16POS GOLD SOLDR
ETC

G31S20A

Mains Power Connector,
ALTECH

G31S50A

Mains Power Connector,
ALTECH

G31S70A

Mains Power Connector,
ALTECH

G31TS-61013HA

INTEGRATED MODULAR JACK
SUPERWORLD