‘105’ SERIES REMOTE RECEIVER DECODERS  
Remote Decoder; Radio, Infra-Red  
4 Relay Channels – Expandable To 15  
Radio Freqs; 433 / 458 MHz  
IP65 Rated Enclosure  
Easy Installation Via Screw Terminals  
230Vac Or 12-30Vdc Supply  
15 CMOS/TTL Channel O/P's  
Led Indication of Each Relay Output.  
Momentary or Latching Outputs  
1 Timed Output Adjustable 0 To 255 Secs  
Relay Contacts 230Vac (5A pk, 2.5A cont)  
Requires No Radio Licence  
Description  
A general-purpose Rx decoder which may operate as radio or infra-red system. The unit is supplied in a tough  
ABS enclosure with IP65 rating, complete and ready to operate.  
As a radio or infrared Rx decoder, the system may be supplied as one of several options to enable the user to  
choose the optimum frequency modulation and range.  
The Rx decoder has a self-learning feature, which enables it to learn the signature code of up to 50 individual  
RF Solutions KEELOQ Tx encoders.  
Connections to the power supply and relay outputs are provided through screw terminals (these are the only  
connections required). The output relays are rated 2.5A @ 240Vac operating as either momentary of latched  
operation. An additional ”Low battery” LED and relay may be fitted to indicate that the Tx encoder battery  
voltage is low.  
Output 1 has a variable time feature, which may be adjusted to give a timed output (upto 4 minutes). A further  
15 momentary digital outputs are also provided for expansion using the ‘115’ Expander (See datasheet  
DS115).  
Performance Table  
Modulation  
RF Frequency  
Transmit Output Power  
Range **  
(m)  
(MHz)  
-
(mW)  
-
Infra-Red  
AM  
20  
433  
10  
45  
QM  
433  
10  
100  
FMNB  
433NB  
433  
10  
800  
10  
200  
FM  
458  
500  
3,000  
** Range stated is optimum, direct line of sight. In worst conditions this can be reduced by over 50%  
DS105-6 April ‘05  
©2003 Reg. No. 227 4001, England  
Page 1  
‘105’ SERIES REMOTE RECEIVER DECODERS  
Connections  
ANT  
D8  
F1  
D7  
D10  
D9  
POWER LED  
T1  
J4  
LEARN LED  
The  
decoder  
requires  
either a  
BATT LOW LED  
SW1  
INFRA-RED  
HEADER  
E
N
L
J7  
230Vac  
Mains  
MAINS  
TRANSFORMER  
RF RECEIVER / PAGER  
J2  
J3  
single  
J5  
12-30 Vdc  
supply or  
240Vac  
mains.  
12-30  
Vdc  
CH4  
VR1  
0V  
CH4  
CH2  
CH3  
GND  
RLY  
9
Connector to  
Expander  
RLY 1  
RLY 2  
RLY 3  
RLY 4  
J9  
J10  
J11  
J12  
NOT BOTH!  
J14  
N/O COMM N/C  
LOW BATT  
N/O COMM N/C  
O/P1  
N/O COMM N/C  
O/P2  
N/O COMM N/C  
O/P3  
N/O COMM N/C  
O/P4  
Warning!  
The unit is designed to be a fixed installation, which may be connected to a mains supply. Before removing  
the cover ensure that the mains input supply is removed. Any operation of the product that involves removal  
of the front cover should only be carried out by a competent person or qualified electrician.  
Configuration the Outputs (Jumper Links J2, J3)  
These links configure the operation of the digital outputs according to the table below.  
NOTE: The link status is read only on power up, after changing the links please to remove and re-apply  
power.  
The system is supplied with relay(s) type OMRON GL5114P or equivalent.  
Note: The user must ensure that the load connected does not overload the relay!  
J2  
J3  
RL 1  
Latch  
Timed  
Latch  
Timed  
RL 2  
RL 3  
RL 4  
Open  
Open  
Latch  
Latch  
Latch  
Open  
Connected  
Open  
Momentary Momentary Momentary  
Connected  
Connected  
Latch  
Momentary Momentary  
Latch Latch  
Connected  
Momentary  
Latch:  
The relay operates until the next valid transmission is received  
Momentary: The relay operates momentarily, or for as long as the Tx encoder switch is held on.  
Removing Timed Output: Turn the trimmer (VR1) fully Clockwise.  
Timed Output (O/P1)  
This is a variable timed output controlled by VR1. This may be adjusted from no delay to a maximum of 4  
minutes 15 seconds. Turning VR1 anti-clockwise increases the output delay.  
A timed output is triggered by a signal from the transmitter, subsequent signals from the transmitter will cancel  
the timed output.  
DS105-6 April ‘05  
©2003 Reg. No. 227 4001, England  
Page 2  
‘105’ SERIES REMOTE RECEIVER DECODERS  
Low Battery Output  
The low battery feature informs the user that the Tx encoder used has a low voltage battery.  
The LOW BATT channel operates if the Rx decoder has received a transmitted signal with low voltage signal  
present. This will continue to operate until a transmitted signal without the low voltage signal has been  
received.  
NOTE: The LOW BATT relay is NOT fitted as standard, a relay of type BT47W/6 or equivalent can be used.  
Expanding the system to 15 Relay outputs  
The EX115C16A unit is available to connect directly to the ‘105’ Series Decoder providing 15 momentary relay  
outputs. For further information please see Datasheet DS115.  
Learning A New Transmitter Encoder  
1. Press and release the programming switch (SW1)  
2. Note that the Learn LED will illuminate  
3. Depress and release the transmitter once, LED on the decoder will extinguish  
4. Depress and release the transmitter again, LED on the decoder will flash  
5. After the LED has stopped flashing the transmitter has been successfully taught to the decoder  
6. This transmitter will now operate the system  
Golden Transmitter: A special ‘golden transmitter’ encoder is available which when operated, causes the  
same function as the user pressing the ‘Learn Switch’ This enables ‘remote Learning’ (for applications where  
the ‘105’ decoder is inaccessible. For further information please contact our sales dept.  
Erasing Existing Tx Encoder  
1. To completely erase the Tx encoders, press SW1 on the Rx decoder for 10 seconds.  
2. The learn LED will turn off after the 10 seconds to indicate the Tx encoder(s) have been erased  
NOTE: You cannot erase individual Tx encoders  
**Range  
Please note that all radio systems are dependant on a radio signal being received through airspace.  
The range quoted is the optimal in direct line of sight without obstacles and in good atmospheric conditions.  
Range is affected by many things, e.g. local environmental conditions, atmospheric conditions, interference  
from other radio transmitters.  
In very worse case applications the range quoted may be reduced to 30% of the optimal range stated.  
Technical Specifications  
Dimensions: Enclosure: 190 x 120 x 60 mm (PCB: 174 x 106mm)  
Storage Temperature; -10 to +70o Celsius.  
Electrical Characteristics  
Supply Voltage  
Supply Current: Quiescent  
Time from Encoder Switch depressed to Decoder  
output change  
Operating Temperature; 0 to +55o Celsius.  
Min  
Typical  
Max  
30.0  
Units  
V
mA  
11.0  
12.0  
25  
100  
300  
mSecs  
Time from Encoder Switch release to Decoder output  
change  
mSecs  
All Relays operating  
Relay Rating* (240Vac) RLY1-4  
Low Battery Relay Rating (RLY9)  
400  
2.5  
mA  
A
A @12Vdc  
5
2
*The relay contacts in this unit are for functional use only and must not be used for isolation purposes  
DS105-6 April ‘05  
©2003 Reg. No. 227 4001, England  
Page 3  
‘105’ SERIES REMOTE RECEIVER DECODERS  
Part Numbering  
Universal IR, AMS and QM Series Decoders  
Relay  
Outputs  
Freq  
(MHz)  
Range**  
(Metres)  
Compatible RFSL  
Encoders  
Part Number  
Description  
80  
AM-110 Series  
100  
102C-433Q Series  
Universal Decoder  
(AM, QM and IR)  
U105  
4
433.92  
20  
20  
IR106 Series  
IR102 Series  
‘FM105’ Series Decoders  
Relay  
Outputs  
Freq  
(MHz)  
Range**  
(Metres)  
Compatible RFSL  
Encoders  
Part Number  
Description  
FM 433 Radio Modules  
for increased Range  
FM 433 Narrow Band  
Radio Modules for  
increased Range  
105-433F  
4
433.92  
200  
102Cx-433F Series  
105-433NBF  
4
433.525  
800  
102Cx-525N Series  
Long Range Remote  
Control  
FM-103Cx-458 Series  
FM-107Cx-458 Series  
105-458F  
4
458.850  
3000  
** Range stated is optimum, direct line of sight. In worst conditions this can be reduced by over 50%  
For more information or general enquiries, please contact  
R. F. Solutions Ltd.,  
Unit 21, Cliffe Industrial Estate,  
South Street, Lewes,  
E Sussex, BN8 6JL. England  
Tel +44 (0)1273 898 000  
Fax +44 (0)1273 480 661  
Email sales@rfsolutions.co.uk  
http://www.rfsolutions.co.uk  
RF Solutions is a member of the Low Power Radio Association  
Information contained in this document is believed to be accurate, however no representation or warranty is given and R.F. Solutions Ltd. assumes no liability with respect to the accuracy of such information.  
Use of R.F.Solutions as critical components in life support systems is not authorised except with express written approval from R.F.Solutions Ltd.  
DS105-6 April ‘05  
©2003 Reg. No. 227 4001, England  
Page 4  

相关型号:

105-433FR2

‘102 SERIES RADIO / IR ENCODER TRANSMITTERS
RFSOLUTIONS

105-433NBF

REMOTE RECEIVER DECODERS
RFSOLUTIONS

105-458F

REMOTE RECEIVER DECODERS
RFSOLUTIONS

105-471HS

General Purpose Inductor, 0.47uH, 3%, 1 Element, Iron-Core, SMD, CHIP
API

105-471K

Micro i Chip Inductors
API

105-471KS

General Purpose Inductor, 0.47uH, 10%, 1 Element, Iron-Core, SMD, 1010, CHIP
API

105-472FS

General Purpose Inductor, 4.7uH, 1%, 1 Element, Iron-Core, SMD, CHIP
API

105-472HS

General Purpose Inductor, 4.7uH, 3%, 1 Element, Iron-Core, SMD, CHIP
API

105-472K

Micro i Chip Inductors
API

105-561FS

General Purpose Inductor, 0.56uH, 1%, 1 Element, Iron-Core, SMD, CHIP
API

105-561JS

General Purpose Inductor, 0.56uH, 5%, 1 Element, Iron-Core, SMD, CHIP
API

105-561K

Micro i Chip Inductors
API