DS-C2O-3 [RFSOLUTIONS]

Easy to Configure using SMS commands.; 易于配置使用短信指令。
DS-C2O-3
型号: DS-C2O-3
厂家: RFSOLUTIONS.LTD    RFSOLUTIONS.LTD
描述:

Easy to Configure using SMS commands.
易于配置使用短信指令。

文件: 总8页 (文件大小:2903K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
C2O  
CALL ‘2OPEN USING YOUR MOBILE PHONE  
Features  
Easy to Configure using SMS  
commands.  
User Password Controlled  
Relay Output rated 1.2KW  
‘White List’ upto 100 Tel No’s  
Signal Strength Indication  
Internal Antenna  
Waterproof Enclosure IP68  
(Pressure Washer Proof)  
Easy Operation  
Access Control  
User Calls C2O  
Gates / Barriers / Doors  
Emergency Alarms  
Covert Systems  
C2O Rejects call  
If valid C2O operates Output  
Remote Control  
Ordering Information  
PART No  
C2O  
SIM-O2  
Description  
Call2Open Controller IP68  
Contract Simcard SMS Only  
DS-C2O-2  
Introduction  
Call ‘2’ open (C2O) is a self contained access Control Solution which provides relay changover  
contact output which can be used to operate gates / barriers etc.  
When C2O receives a telephone call, if ‘White Mode’ is enabled It checks the caller’s tele-  
phone number with its own ‘White List’ and if valid, C2O operates its relay output momentari-  
ly.  
Because C2O rejects the call there are no call charges incurred. (Using current call charging  
structures).  
The user can set upto 100 numbers on the white list, or set the C2O ‘Open’ to any caller  
Typical Application Connection:  
Normally the C2O output relay is wired across the switch which operates the Gate.  
In order to connect the C2O across a standard push switch the relay COM and NO contacts  
are wired in parallel to the users gate wall push switch.  
Hardware Features  
SIM card  
The unit will accept SIM cards of most types subject to the following restrictions.  
The SIM card should be inserted into C2O before applying power  
Only 3 Volt SIM cards should be used.  
The message memory of the SIM card should be clear before it is fitted to the C2O unit.  
SIM cards that have been protected by means of a PIN (in a mobile phone) will not operate in  
the unit.  
Some types of pay-as-you-go SIM cards may require regular call activity (once every 3 - 6  
months) to remain registered.  
RF Solutions recommends O2 and Videophone SIM card and has carried out extensive testing  
using the SIM cards we have for these two networks.  
Problems have been identified with Orange SIM cards with this product.  
No guarantee can be given for the operation of this product with any network except those  
that have been tested by RF Solutions.  
DS-C2O-3  
Onboard LED’s Indication / Signal Strength  
There are four LEDs on the circuit board. The Green LED indicates power is applied  
The three Red LEDs indicate the status of C2O as below  
During Initialisation After Power UP  
RED LED Action  
Description  
LED’s illuminate alternately  
Power-up initialisation (can take many seconds)  
All LED’s flash together  
No network found  
Normal Operation  
RED LED Action  
No LEDs  
Description  
No signal  
One LED on Steady  
Low signal strength  
Two LEDs on Steady  
Three LEDs on Steady  
Medium signal strength  
High signal strength  
When Transmitting or Receiving a TEXT  
RED LED Action  
Description  
One LED Flashing  
SMS being Received  
SMS being Transmitted  
TWO LED’s Flashing  
Changeover Contact Outputs  
Two relay outputs are provided on C2O and C2O-DIN, which provide a ‘switch’ output as below.  
Relay Connections when  
NOT Operating  
Relay Connections when  
OPERATING  
Power Connections  
The C2O unit can be powered from 12 or 24Vdc, a mains power supply is also available. Power  
is connected via the Power Screw Terminal.  
DS-C2O-3  
Extending the Antenna  
For low signal areas the internal antenna may be replaced with an external antenna. We offer  
the following options.  
Please Note: Fitting the bulkhead connector in the enclosure will mean that the enclosure is  
no longer IP68! Additional water sealing will be required if the unit is exposed.  
CBA-UFLSMA-1  
This cable connects onto the GSM Engine and provides a  
bulkhead mounting SMA connector which may be fitted  
to the enclosure, The external antenna below connect  
directly.  
Optional External Mount Gain Antenna  
ANT-GSM5WM  
Wall Mount Whip Antenna  
Gain +5dB  
Height ~250mm  
3m Connecting Lead  
OUTSIDE-TSMA  
Wall Mount Antenna  
Gain +3dB  
Dimensions 130 x 45 x 27mm  
3m Connecting Lead  
GSM20-ANT  
Magnetic mount type Whip Antenna  
Gain +3db  
Height ~ 236 mm (including magnetic base)  
Cable length 2.5m  
DS-C2O-3  
ANT-GSMPUKS  
Rugged Low Profile ‘Puck’ Antenna  
+2dBi Gain  
3metres Cable  
ANT-GSMSTUB4  
Stubby Magnetic Mount  
Gain: +4dBi  
Height ~110mm  
3m Connecting Lead  
Waterproof Power Supply PSU12V1AIN-IP  
Waterproof Resin Potted Unit (IP67)  
Size 83 x 37 x 30mm  
Input 100-240Vac Output 12Vdc 1A  
Wall Fixing Lugs  
Supplied with 3.3m lead  
DS-C2O-3  
Sending Text Commands  
~ means a ‘space’ in the message.  
Description  
Command  
This is the first command that must be sent within 5 minutes from in-  
tial power up.  
The UPW can be any combination of letters/numbers from 5 to10 char-  
acters.  
If for any reason the unit password is lost or miss-entered the user  
must remove all power to the unit for 1 minute, when power is reap-  
plied the user may then use the UPW command to set a new unit pass-  
word.  
Unit Password  
(UPW)  
Command Example: UPW~Password123  
Response:  
UPW~OK  
***NOTE THIS COMMAND IS CASE SENSITIVE!***  
This command sets an activation time of the relay outputs.  
If ‘t’ is set to a value from 1 to 9 then this sets the number of seconds  
for which the output remains on after an ON command.  
If ‘t’ is set to ‘0’, then the output will Latch ‘ON’ permanently  
Output delay time  
(ODEL)  
Command Example: Password123~ODEL1~7  
Response:  
UID~ODEL1~7~OK  
The <UNIT ID> is an alphanumeric string consisting 4 to 10 charac-  
ters.  
This string of characters sets the ‘identity’ of the C2O unit, and is in-  
cluded in any response to identify the C2O unit to the user  
Command:  
Unit Identity  
(UID)  
Password123~UID~Identity7  
Response:  
Identity7~UID~OK  
DS-C2O-3  
Additional Commands for using the White List  
Turns ON White list check. When C2O receives a call, it checks the  
Caller ID, If it is in the list it will activate the output, then reject the  
call (so there will be no charge).  
Enable Call2Open Mode  
from White List  
Command Example: Password123~CTOWHL  
(CTOWHL)  
Response:  
UID~CTOWHL~OK  
There is a max of 99 numbers that can be stored.  
We advise you keep a separate list numbers their positions.  
Add a number to the  
White List  
Command Example to add 1273898000 to location 4:  
Password1234~WHL04~1273898000  
(WHL)  
Response: Password123~WHL04~1273898000~OK  
Note: If your number has more than 23 digits, use the rightmost  
ones. For example, if your number is 33446665555 you should pro-  
gram 3446665555.  
Reports back a telephone number from the White list  
Check a number in the  
White List  
Command Example to report back the tel no in position 32:  
Password123~WHL032?  
(WHL?)  
Response: Password123~WHL032~1273898000  
Command Example to delete the Tel no at loc’n 01:  
Password123~WHL01D  
Delete a number in the  
White List  
Response:  
(WHLD)  
Password123~WHL01~<0033612345678>~deleted  
This command Deletes all telephone numbers within the White list  
Command:  
Password123~WHLALLD  
Response  
Password123~WHL~<ALL>~deleted  
Delete ALL numbers in  
the White List  
(WHLALLD)  
Turns OFF White list check. When C2O receives a call from ANY Tel  
number, it will activate the output, then reject the call (so there will  
be no charge).  
Enable Call2Open Mode  
from Any number  
Command Example: Password123~CTOANY  
(CTOANY)  
Response:  
UID~CTOANY~OK  
DS-C2O-3  
C2O  
Technical Specifications  
Storage Temperature:  
C2O Enclosure Rating  
C2O Dimensions  
-10 to +70o Celsius. Operating Temperature: 0 to +55o Celsius.  
IP68  
169 x 132 x 85mm  
Electrical Characteristics  
Supply Voltage for 12Vdc  
Supply Voltage for 24Vdc  
Min  
11  
Typical  
12.0  
Max  
14  
Dimension  
Notes  
V
V
23  
24.0  
26.0  
Supply Current for C2O:  
Idle  
Operating  
35  
200  
44  
370  
100  
1000  
mA  
mA  
1
2
Mains rated Relay Rating  
(230Vac)  
5
12  
A
3
Notes  
Refers to maximum supply current required with all components idle.  
Refers to peak supply current required with all components operating. In practice internal reservoir capacitance  
limits the instantaneous peak current to less than 500 mA.  
The relay contacts in this unit are for functional switching only and must not be used for isolation purposes.  
Disclaimer:  
Whilst the information in this document is believed to be correct at the time of issue, R.F.Solutions Ltd does not accept any liability whatsoever for its accuracy, adequacy or  
completeness. No express or implied warranty or representation is given relating to the information contained in this document. R.F.Solutions Ltd reserves the right to make  
changes and improvements to the product(s) described herein without notice. Buyers and other users should determine for themselves the suitability of any such information or  
products for their own particular requirements or specification(s). R.F.Solutions Ltd shall not be liable for any loss or damage caused as a result of user’s own determination of  
how to deploy or use R.F.Solutions Ltd’s products. Use of R.F.Solutions Ltd products or components in life support and/or safety applications is not authorised except with  
express written approval. No licences are created, implicitly or otherwise, under any of R.F.Solutions Ltd’s intellectual property rights. Liability for loss or damage resulting or  
caused by reliance on the information contained herein or from the use of the product (including liability resulting from negligence or where R.F.Solutions Ltd was aware of the  
possibility of such loss or damage arising) is excluded. This will not operate to limit or restrict R.F.Solutions Ltd’s liability for death or personal injury resulting from its negli-  
gence.  
DS-C2O-2  

相关型号:

DS-ELITE-1

Whatever your switching application the ELITE Remote control system with 4 individual 230V outputs and it’s completely waterproof IP68 enclosure will be a great choice.
RFSOLUTIONS

DS-FIRETRAP-5

Supplied ready to operate the FIRE-TRAP system is designed for continu-ous operation 365 days of the year.
RFSOLUTIONS

DS-GPSMG-2

A compact Antenna for GPS applications where high performance is required from a small size. The antenna includes a Low Noise Amplifier and incorporates both magnetic mount and screw fixings.
RFSOLUTIONS

DS-MAFL-011014_V1

CATV Diplex Filter
TE

DS-MAFL-011015_V1

CATV Diplex Filter
TE

DS-PROTEXT-9

PROTEXT - GSM REMOTE CONTROL
RFSOLUTIONS

DS-S29804

Stratix II EP2S60 DSP Development Board
ALTERA

DS-SERIES

Power Dividers Space Qualified
ETC

DS-ZULU

RF Wireless MCU
RFSOLUTIONS

DS-ZULUM

Radio MODEM Module
RFSOLUTIONS

DS-ZULUT

Smart Radio Telemetry Module
RFSOLUTIONS

DS001

Spartan-II FPGA Family Data Sheet
XILINX