3MDC10-155-20AN [RMT]

Blank ceramics (not metallized);
3MDC10-155-20AN
型号: 3MDC10-155-20AN
厂家: RMT Ltd.    RMT Ltd.
描述:

Blank ceramics (not metallized)

文件: 总8页 (文件大小:2609K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Thermoelectric Cooling Solutions  
Performance Parameters  
3MDC10-155-XXAN  
ΔTmax Qmax  
Imax  
A
Umax AC R  
H
Type  
K
W
V
Ohm mm  
3MDC10-155-xxAN (N=113)  
3MDC10-155-05AN  
3MDC10-155-08AN  
3MDC10-155-10AN  
3MDC10-155-15AN  
3MDC10-155-20AN  
100  
105  
106  
107  
108  
11.8  
7.9  
6.5  
4.5  
3.4  
5.5  
3.8  
3.1  
2.2  
1.7  
1.76  
2.68  
3.29  
4.82  
6.34  
3.8  
4.7  
5.3  
6.8  
8.3  
11.3  
Performance data are given for 300K, vacuum  
Dimensions  
Manufacturing options  
A. TEC Assembly:  
C. Ceramics Surface Options:  
D. Thermistor (optional)  
* 1. Solder SnSb (Tmelt=230°C)  
1. Blank ceramics (not metallized)  
Can be mounted to cold side  
ceramics edge. Calibration  
is  
2. Solder AuSn (Tmelt=280°C)  
2. Metallized (Au plating)  
available by request.  
3. Metallized and pre-tinned with:  
3.1 Solder 117 (In-Sn, Tmelt =117°C)  
3.2 Solder 138 (Sn-Bi, Tmelt = 138°C)  
3.3 Solder 143 (In-Ag, Tmelt = 143°C)  
3.4 Solder 157 (In, Tmelt = 157°C)  
3.5 Solder 183 (Pb-Sn, Tmelt =183°C)  
B. Ceramics:  
E. Terminal contacts  
1. Blank, tinned Copper  
2. Insulated Wires  
1.Pure Al2O3(100%)  
2.Alumina (Al2O3- 96%)  
*
3.Aluminum Nitride (AlN)  
* - used by default  
3. Insulated, color coded  
3.6 Optional (specified by Customer)  
!
46 Warshavskoe shosse. Moscow 115230 Russia, ph: +7-499-678-2082, fax: +7-499-678-2083, web: www.rmtltd.ru  
Copyright 2013. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.  
Page 1 of 8  
Thermoelectric Cooling Solutions  
3MDC10-155-05AN  
Performance Data  
ΔTmax  
K
Qmax  
W
Imax  
A
Umax  
V
ΔTmax  
K
Qmax  
W
Imax  
A
Umax  
V
@ 27ºC, Vacuum  
@50ºC, N2  
3MDC10-155-05AN  
100  
11.76  
5.5  
11.3  
3MDC10-155-05AN  
105  
13.32  
5.7  
12.7  
Note: Performance data is specified at optimal conditions (TEC hot side is stabilized at ambient temperature). Heatsink thermal  
resistance is not included into estimations. Use TECCad Software for estimations under different conditions.  
3MDC10-155-08AN  
Performance Data  
ΔTmax  
K
Qmax  
W
Imax  
A
Umax  
V
ΔTmax  
K
Qmax  
W
Imax  
A
Umax  
V
@ 27ºC, Vacuum  
@50ºC, N2  
3MDC10-155-08AN  
105  
7.89  
3.8  
11.3  
3MDC10-155-08AN  
106  
8.89  
4.0  
12.7  
Note: Performance data is specified at optimal conditions (TEC hot side is stabilized at ambient temperature). Heatsink  
thermal resistance is not included into estimations. Use TECCad Software for estimations under dierent conditions.  
!
46 Warshavskoe shosse. Moscow 115230 Russia, ph: +7-499-678-2082, fax: +7-499-678-2083, web: www.rmtltd.ru  
Copyright 2013. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.  
Page 2 of 8  
Thermoelectric Cooling Solutions  
3MDC10-155-10AN  
Performance Data  
ΔTmax  
K
Qmax  
W
Imax  
A
Umax  
V
ΔTmax  
K
Qmax  
W
Imax  
A
Umax  
V
@ 27ºC, Vacuum  
@50ºC, N2  
3MDC10-155-10AN  
106  
6.47  
3.1  
11.3  
3MDC10-155-10AN  
105  
7.28  
3.3  
12.7  
Note: Performance data is specified at optimal conditions (TEC hot side is stabilized at ambient temperature). Heatsink thermal  
resistance is not included into estimations. Use TECCad Software for estimations under different conditions.  
3MDC10-155-15AN  
Performance Data  
ΔTmax  
K
Qmax  
W
Imax  
A
Umax  
V
ΔTmax  
K
Qmax  
W
Imax  
A
Umax  
V
@ 27ºC, Vacuum  
@50ºC, N2  
3MDC10-155-15AN  
107  
4.46  
2.2  
11.3  
3MDC10-155-15AN  
101  
5.01  
2.3  
12.7  
Note: Performance data is specified at optimal conditions (TEC hot side is stabilized at ambient temperature). Heatsink thermal  
resistance is not included into estimations. Use TECCad Software for estimations under different conditions.  
!
46 Warshavskoe shosse. Moscow 115230 Russia, ph: +7-499-678-2082, fax: +7-499-678-2083, web: www.rmtltd.ru  
Copyright 2013. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.  
Page 3 of 8  
Thermoelectric Cooling Solutions  
3MDC10-155-20AN  
Performance Data  
ΔTmax  
K
Qmax  
W
Imax  
A
Umax  
V
ΔTmax  
K
Qmax  
W
Imax  
A
Umax  
V
@ 27ºC, Vacuum  
@50ºC, N2  
3MDC10-155-20AN  
108  
3.41  
1.7  
11.3  
3MDC10-155-20AN  
97  
3.83  
1.8  
12.7  
Note: Performance data is specified at optimal conditions (TEC hot side is stabilized at ambient temperature). Heatsink thermal  
resistance is not included into estimations. Use TECCad Software for estimations under different conditions.  
Important notes  
1. TEC Performance in this datasheet is specified in two standard ambient condition modes (vacuum, +27ºC and dry  
nitrogen (N2), +50ºC). The performance may differ under other conditions. Please, use TECCad software from  
RMT Ltd web site or contact RMT or its branch specialists directly for additional TEC performance info.  
2. TEC ACR and Umax values are sensitive to ambient temperature. These values can be different from those  
specified in the datasheet at other ambient conditions. ACR and Umax raise with ambient temperature increasing.  
3. TEC cooling capacity (Qmax) raises with ambient temperature. Please, use TECCad software for additional info or  
contact RMT specialists directly.  
4. Thermoelectric coolers have the best performance in the temperature range from near room up to +80..90ºC. The  
performance is lower at temperatures below 0ºC. TEC is not suitable to work at cryogenic temperatures.  
5. Driving a TEC at Imax or Umax doesn’t mean max performance mode. The real optimal mode may depend on  
operating conditions and heatload. In fact a better performance can be reached at operating current and voltage  
lower than Imax and Umax values specified in the datasheet.  
6. It is strongly recommended to avoid a direct mounting of thermoelectric cooler to pure Copper, Aluminium or  
Nickel materials as well as a mounting of objects from these materials on TEC cold side. Any material with high  
CTE may affect TEC lifetime and/or damage it in case of improper mounting, thermal shock or temperature  
cycling. In case of above mentioned materials necessity, it is recommended to use soft solders or glues with large  
modulus of elasticity (Indium-based solders or silicon-based thermoconductive glues).  
7. RMT Ltd confirms that all thermoelectric coolers meet the requirements of Telcordia GR-468 standard. The up-to-  
date Reliability Report is available by request. RMT Ltd warranties thermoelectric coolers lifetime no less than  
250K-300K operating hours under normal application conditions.  
!
46 Warshavskoe shosse. Moscow 115230 Russia, ph: +7-499-678-2082, fax: +7-499-678-2083, web: www.rmtltd.ru  
Copyright 2013. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.  
Page 4 of 8  
Thermoelectric Cooling Solutions  
Additional Options  
TEC Polarity  
TEC Polarity can be modified by request. The  
specified polarity in this datasheet is typical.  
It can be reversed in accordance to Customer  
application requirements.  
-
+
Standard polarity  
Reversed polarity  
+
-
Terminal Wires Options  
The wires are of tinned Copper, blank (not isolated)  
by default. Various options for isolated wires are  
available by request. The available solutions  
include isolated wires, isolated color-coded wires,  
flexible multicore wires and more.  
Standard wires,  
tinned Copper  
Isolated wires  
Customized Au Patterns  
Customized Au patterns on thermoelectric cooler  
cold side are available by request. Selective Pre-  
tinning over pattern is also available. Please,  
contact RMT Ltd for additional information about  
customized Au patterns requirements.  
Customized Au pattern  
on cold side  
Selective pre-tinning  
over pattern  
TEC Height modification  
Standard TEC height can be modified without  
performance changes by using ceramics of  
different thickness. 3MDC10 Series thermoelectric  
cooler height (specified in this datasheet) can be  
modified in a range 0..+2.0mm by request.  
Standard height  
Modified height,  
another ceramics  
thickness  
!
46 Warshavskoe shosse. Moscow 115230 Russia, ph: +7-499-678-2082, fax: +7-499-678-2083, web: www.rmtltd.ru  
Copyright 2013. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.  
Page 5 of 8  
Thermoelectric Cooling Solutions  
Thermoelectric Cooler Overview  
Cold side Ceramics  
(top side)  
AlN Ceramics by default  
(Al2O3 solution is available  
by request)  
TE Cooler Lead Free  
Internal Assembly  
(Lead-Free Solder 230,  
Sn-Sb)  
Middle Ceramics  
TEC Polarity  
(can be modified by  
request)  
Pellets (BiTe posts)  
Hot Side Ceramics  
-
(bottom side)  
Terminal Wires  
+
Application Tips  
1. Never heat TE module more than 200˚C (TEC  
assembled at 230˚C).  
3. Connect TE module to DC power supply according  
to polarity.  
2. Never use TE module without an attached heat sink  
at hot (bottom) side.  
4. Do not apply DC current higher than Imax.  
Installation  
1. Mechanical Mounting. TEC is placed between two heat exchangers . This construction is fixed by screws or in  
another mechanical way. It is suitable for large modules (with dimensions 30x30mm and larger). Miniature types  
require other assembling methods in most cases.  
1. Soldering. This method is suitable for a TE module with metallized outside surfaces. RMT provides this option  
and also makes pre-tinning for TE modules.  
2. Glueing. It is an up-to-date method that is used by many customers due to availability of glues with good  
thermoconductive properties. A glue is usually based on some epoxy compound filled with some  
thermoconductive material such as graphite or diamond powders, silver, SiN and others. The application of a  
specific type depends on application features and the type of a TE module.  
Object being cooled  
Object being cooled  
TEC  
TEC  
3
1
2
Screw mounting  
Heatsink  
Soldering  
Heatsink  
Gluing  
!
46 Warshavskoe shosse. Moscow 115230 Russia, ph: +7-499-678-2082, fax: +7-499-678-2083, web: www.rmtltd.ru  
Copyright 2013. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.  
Page 6 of 8  
Thermoelectric Cooling Solutions  
Contacts  
!
RMT Ltd. Headquarters  
Warshavskoe sh. 46, 115230, Moscow  
Russia  
Phone: +7-499-678-2082  
Fax: +7-499-678-2083  
Web: www.rmtltd.ru  
Email: info@rmtltd.ru  
!
EUROPE/USA - TEC Microsystems GmbH  
Schwarzschildstrasse 3, 12489 Berlin  
Germany  
Tel. +49 30 6789 3314  
Fax+49 30 6789 3315  
Web: www.tec-microsystems.com  
Email: info@tec-microsystems.com  
!
CHINA - ProTEC Ltd.  
ꢀꢁꢂꢃꢄꢅꢆꢇꢈꢉꢊꢋꢌB207  
ꢎꢏꢐ+86-755-61596066  
ꢑꢒꢐ+86-755-61596036  
ꢓꢔꢐ518054  
Web: www.protecltd.com  
Email: info@protecltd.com  
!
46 Warshavskoe shosse. Moscow 115230 Russia, ph: +7-499-678-2082, fax: +7-499-678-2083, web: www.rmtltd.ru  
Copyright 2013. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.  
Page 7 of 8  
Thermoelectric Cooling Solutions  
!
Legal Notice  
!
All logos, images, trademarks and product names (collectively Materials) are proprietary to RMT Ltd and/ or any  
of its affiliates, or subsidiaries, or other respective owners that have granted RMT Ltd the permission and/or  
license to use such Materials. All images are provided by RMT Ltd. and are subjects of copyright protection.  
RMT Ltd, TEC Microsystems GmbH and ProTEC Ltd do not grant a copyright license (express or implied) to the  
Recipient, except that Recipient may reproduce the logos, images and text materials in this press-release  
without any alteration for non-promotional or editorial purposes only with a written note about materials owner.  
!
Copyright protection warning  
!
Graphic materials and text from this datasheet may not be used commercially without a prior response in  
writing on company letterhead and signed by RMT Ltd authority. Thank you for respecting the intellectual  
property rights protected by the International Copyright laws.  
Warning: All datasheet images contain RMT Ltd hidden watermark for the immediate proof of their origin.  
RMT Image  
Hidden Watermark  
!
46 Warshavskoe shosse. Moscow 115230 Russia, ph: +7-499-678-2082, fax: +7-499-678-2083, web: www.rmtltd.ru  
Copyright 2013. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.  
Page 8 of 8  

相关型号:

3MDC10071

Blank ceramics (not metallized)
RMT

3MDC10113

Blank ceramics (not metallized)
RMT

3MDC10155

Blank ceramics (not metallized)
RMT

3MI-15LC3907

Isolator, 3500MHz Min, 4200MHz Max
HITACHI

3MI-15RC3907

Isolator, 3500MHz Min, 4200MHz Max
HITACHI

3MI-20LC3506

Isolator, 3200MHz Min, 3800MHz Max
HITACHI

3MI-20RC3506

Isolator, 3200MHz Min, 3800MHz Max
HITACHI

3MN-DP-7-AP1/1-M2GE

Pushbutton Switch, DPDT, Latched And Momentary, 1A, 28VDC, Solder Terminal, Through Hole-straight
Carling Techn

3MN-DP-7-AP1/1-M5-1GE

Pushbutton Switch, DPDT, Latched And Momentary, 1A, 28VDC, Wire Wrap Terminal, Panel Mount-threaded
Carling Techn

3MN-DP-7-AP1/1-M5-1RE

Pushbutton Switch, DPDT, Latched And Momentary, 0.02A, 20VDC, Wire Wrap Terminal, Panel Mount-threaded
Carling Techn

3MN-DP-7-AP1/1-M5-3RE

Pushbutton Switch, DPDT, Momentary, 0.02A, 20VDC, Wire Wrap Terminal, Panel Mount
Carling Techn

3MN-DP-7-AP1/1-M6GE

Pushbutton Switch, DPDT, Latched And Momentary, 1A, 28VDC, Solder Terminal, Through Hole-right Angle
Carling Techn