DM7407M [ROCHESTER]
Buffer, TTL/H/L Series, 6-Func, 1-Input, TTL, PDSO14, 0.150 INCH, MS-012, SOIC-14;型号: | DM7407M |
厂家: | Rochester Electronics |
描述: | Buffer, TTL/H/L Series, 6-Func, 1-Input, TTL, PDSO14, 0.150 INCH, MS-012, SOIC-14 栅 光电二极管 逻辑集成电路 触发器 |
文件: | 总4页 (文件大小:47K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
December 1986
Revised July 2001
DM7407
Hex Buffers with High Voltage Open-Collector Outputs
General Description
Pull-Up Resistor Equations
This device contains six independent gates each of which
performs a buffer function. The open-collector outputs
require external pull-up resistors for proper logical opera-
tion.
Where:
N1 (IOH) = total maximum output high current
for all outputs tied to pull-up resistor
2 (IIH) = total maximum input high current for
N
all inputs tied to pull-up resistor
N3 (IIL) = total maximum input low current for
all inputs tied to pull-up resistor
Ordering Code:
Order Number Package Number
Package Description
DM7407M
DM7407N
M14A
N14A
14-Lead Small Outline Integrated Circuit (SOIC), JEDEC MS-012, 0.150" Narrow
14-Lead Plastic Dual-In-Line Package (PDIP), JEDEC MS-001, 0.300" Wide
Devices also available in Tape and Reel. Specify by appending the suffix letter “X” to the ordering code.
Connection Diagram
Function Table
Y = A
Input
Output
A
L
Y
L
H
H
H = HIGH Logic Level
L = LOW Logic Level
© 2001 Fairchild Semiconductor Corporation
DS006497
www.fairchildsemi.com
Absolute Maximum Ratings(Note 1)
Note 1: The “Absolute Maximum Ratings” are those values beyond which
the safety of the device cannot be guaranteed. The device should not be
operated at these limits. The parametric values defined in the Electrical
Characteristics tables are not guaranteed at the absolute maximum ratings.
The “Recommended Operating Conditions” table will define the conditions
for actual device operation.
Supply Voltage
Input Voltage
Output Voltage
7V
5.5V
30V
Operating Free Air Temperature Range
Storage Temperature Range
0°C to +70°C
−65°C to +150°C
Recommended Operating Conditions
Symbol
VCC
Parameter
Supply Voltage
Min
4.75
2
Nom
Max
Units
V
5
5.25
VIH
VIL
VOH
IOL
TA
High Level Input Voltage
Low Level Input Voltage
V
0.8
30
40
70
V
High Level Output Voltage
Low Level Output Current
Free Air Operating Temperature
V
mA
°C
0
Electrical Characteristics
over recommended operating free air temperature range (unless otherwise noted)
Typ
Symbol
Parameter
Conditions
Min
Max
−1.5
250
Units
(Note 2)
VI
ICEX
Input Clamp Voltage
V
V
V
V
V
CC = Min, II = −12 mA
CC = Min, VO = 30V
IH = Min
V
HIGH Level
µA
Output Current
LOW Level
VOL
CC = Min, IOL = Max
IL = Max
0.7
Output Voltage
V
I
OL = 16 mA, VCC = Min
0.4
1
II
Input Current @ Max Input Voltage
HIGH Level Input Current
V
V
V
V
V
CC = Max, VI = 5.5V
CC = Max, VI = 2.4V
CC = Max, VI = 0.4V
CC = Max
mA
µA
IIH
40
IIL
LOW Level Input Current
−1.6
41
mA
mA
mA
ICCH
ICCL
Supply Current with Outputs HIGH
Supply Current with Outputs LOW
29
21
CC = Max
30
Note 2: All typicals are at VCC = 5V, TA = 25°C.
Switching Characteristics
at VCC = 5V and TA = 25°C
Symbol
tPLH
Parameter
Propagation Delay Time
Conditions
Min
Max
Units
C
L = 15 pF
L = 110Ω
10
ns
LOW-to-HIGH Level Output
Propagation Delay Time
HIGH-to-LOW Level Output
R
tPHL
30
ns
www.fairchildsemi.com
2
Physical Dimensions inches (millimeters) unless otherwise noted
14-Lead Small Outline Integrated Circuit (SOIC), JEDEC MS-012, 0.150" Narrow
Package Number M14A
3
www.fairchildsemi.com
Physical Dimensions inches (millimeters) unless otherwise noted (Continued)
14-Lead Plastic Dual-In-Line Package (PDIP), JEDEC MS-001, 0.300" Wide
Package Number N14A
Fairchild does not assume any responsibility for use of any circuitry described, no circuit patent licenses are implied and
Fairchild reserves the right at any time without notice to change said circuitry and specifications.
LIFE SUPPORT POLICY
FAIRCHILD’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT
DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT OF FAIRCHILD
SEMICONDUCTOR CORPORATION. As used herein:
1. Life support devices or systems are devices or systems
which, (a) are intended for surgical implant into the
body, or (b) support or sustain life, and (c) whose failure
to perform when properly used in accordance with
instructions for use provided in the labeling, can be rea-
sonably expected to result in a significant injury to the
user.
2. A critical component in any component of a life support
device or system whose failure to perform can be rea-
sonably expected to cause the failure of the life support
device or system, or to affect its safety or effectiveness.
www.fairchildsemi.com
www.fairchildsemi.com
4
©2020 ICPDF网 联系我们和版权申明