140M-D8V-B25 [ROCKWELL]

Thermal Magnetic Circuit Breaker, 3 Pole(s), 2.5A, 500VAC, Din-rail Mount,;
140M-D8V-B25
型号: 140M-D8V-B25
厂家: ROCKWELL INTERNATIONAL CORPORATION.    ROCKWELL INTERNATIONAL CORPORATION.
描述:

Thermal Magnetic Circuit Breaker, 3 Pole(s), 2.5A, 500VAC, Din-rail Mount,

电路保护
文件: 总60页 (文件大小:6027K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Technical Data  
Motor Protection Circuit Breaker and Motor Circuit Protector  
Specifications  
Bulletin 140M  
Topic  
Page  
3
Topic  
Page  
17  
Bulletin 140M Motor Protection Circuit Breakers  
Overview  
Accessories  
3
Specifications  
25  
Catalog Number Explanation  
Application Diagrams  
Product Selection  
5
Application Ratings  
Definition of Type 2 Short Circuit Coordination:  
IEC Performance Data  
Cutoff Current  
25  
6
31  
8
34  
Bulletin 140M Motor Circuit Protectors  
Overview  
11  
11  
12  
13  
15  
44  
Time-Current Characteristic  
Approximate Dimensions  
49  
Catalog Number Explanation  
Application Diagrams  
Product Selection  
51  
Summary of Changes  
This publication adds product selection and accessory information.  
Additional Resources  
These documents contain additional information concerning related products from Rockwell Automation.  
Resource  
Description  
Use of Motor Protection Circuit Breakers with Variable- Frequency Drives,  
publication 140M-AT002  
Provides application information about using 140M devices with variable-frequency  
drives.  
Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1  
Provides general guidelines for installing a Rockwell Automation industrial system.  
Product Certifications website, https://www.rockwellautomation.com/global/certification/ Provides declarations of conformity, certificates, and other certification details.  
overview.page?  
You can view or download publications at http://www.rockwellautomation.com/global/literature-library/  
overview.page. To order paper copies of technical documentation, contact your local Allen-Bradley distributor or  
Rockwell Automation sales representative.  
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
Notes:  
2
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
Bulletin 140M Motor Protection Circuit Breakers  
Overview  
Motor Protection Circuit Breakers may provide the following protective and control functions.  
Disconnect for Motor Branch Circuit  
Branch-Circuit, Short-Circuit Protection (Magnetic Protection)  
Overload Protection (Thermal Protection)  
Switching (Manual)  
In North America, electrical codes require that an individual Motor Branch Circuit be protected by a UL/CSA Listed Fuse, Circuit Breaker or Self-  
Protected Combination Motor Controller.  
140M-C, D, and F Frames  
The 140M-C, D, and F frame Motor Protection Circuit Breakers may have two cULus Listings - as Manual, Self-Protected Combination Motor  
Controllers and as Manual Motor Controllers (with optional approvals for Motor Disconnect and Group Installation). Cat. No. 140M-D8V* can  
also be applied at the output of a variable frequency drive (VFD) in multi-motor applications. See Application Conditions (140M-D8V) on  
page 41 for more information.  
When UL/CSA listed as Manual, Self-Protected Combination Motor Controllers, the 140M Motor Protection Circuit Breakers provide all of the  
necessary NEC/CEC requirements for the protection and control of individual Motor Branch Circuits without additional protective devices.  
At some higher voltages and currents (particularly at 600V), a few of the 140M-C, D, and F frame devices are only UL/CSA Listed as Manual  
Motor Controllers (with optional approvals for Motor Disconnect and Group Installation). In NEC/CEC Group Installations, these devices must  
be applied per the appropriate rules which require the use of an upstream Branch-Circuit, Short-Circuit Protective Device (BCPD).  
Type E and Type F Combination Motor Controllers  
Most of the 140M-C…Fmotor protectioncircuit breakers are UL Listed as a manual Type E self-protected combinationmotor controller.Although  
there are many tests involved, one of the critical tests a self-protected combinationmotor controllermust pass, is to perform 6000 electricaloperations  
and an additional4000 mechanicaloperations after a short circuit.  
By definition, a Type F combinationmotor controllerconsists of a Type E manual self protectedcombinationmotor controllerand a magneticor  
solid-statemotor controller(such as a Bulletin 100-C contactoror an SMC). As with a manual Type E self-protected combinationmotor controller,  
additionalshort-circuitprotectionis not required for the individualmotor circuits.  
A combination of a Bulletin 140M manual self protected combination motor controller and 100-C contactor can be listed as a Type E self-  
protected combination motor controller. In this case, both the 140M and 100-C must pass the additional 6000 electrical and 4000 mechanical  
operational test. In some cases, this may require over sizing of the Bulletin 140M MPCB or the 100-C contactor to achieve weld free performance  
and meet the additional life requirements.  
Standards Compliance and Certifications  
Standards Compliance  
IEC/EN60947-1,-2,-4-1,-5-1  
IEC/EN60204-1  
Certifications  
CE Marked  
CCC  
CSA,C22.2 No.14  
UL508  
CSA Certified  
cULus Listed (File No. E54612, NLRV(7); E205542, NKJH(7); E197878, DIVQ(7);)  
ATEX  
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
3
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
C-Frame  
32  
D-Frame  
32  
F-Frame  
45  
Max. Current Ie  
A
A
A
Current Rating  
0.1…32  
A
1.6…32  
A
6.3…45  
A
Short Circuit Protection  
Standard Magnetic T rip  
High Magnetic Trip  
Magnetic Only Trip (MCP)  
Overload Protection  
Trip Class  
10  
10  
10  
Application at output of VFD (multi-motor)  
Standards Compliance  
CSA22.2, No.14  
(140M-D8V)  
UL508 (Group Installation)  
UL508 Manual, Self Protected (Type E)  
UL508 (Overload Protection)  
IEC60947-1,-2  
(see ratings)  
(see ratings)  
(see ratings)  
(see ratings)  
(see ratings)  
(see ratings)  
IEC60947-4-1  
CE  
ATEX (IEC60079-14)  
CCC  
(up to 25 A)  
(up to 25 A)  
(up to 25 A; except 140M-D8V)  
(up to 25 A)  
Accessories  
External Rotary Operator  
Auxiliary Contacts  
Trip Indication Contacts  
4
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
Catalog Number Explanation  
Examplesgiven in this section are not intended to be used for product selection.  
140M  
C
2
E
A63  
KN  
CC  
GJ  
a
b
c
d
e
f
g
h
a
b
c
d
Bulletin Number  
Description  
Frame/Rating  
Code Description  
Interrupting Rating/Breaking Capacity  
Protection Type  
Description  
Code  
Code  
Description  
Code  
140M Motor Protection Circuit Breaker  
C
32 A  
2
Normal Break  
E
Adj Thermal/ Fixed Mag(13 x In  
Adj Thermal/Fixed Mag  
)
D
32  
45  
A
A
8
High Break  
T
(Fixed at 16...20 x In  
)
Adj Thermal/Fixed Mag application at  
output of VFD (multi-motor)  
F
V
e
f
g
Current Range  
Code Description Example  
Miscellaneous  
Description  
Auxiliary Trip Contacts  
C, D, F Frames  
2nd  
Code  
KN  
Frame Size  
1st  
Code  
A
A=0.10  
A16=0.16  
Black Lockable Knob  
C,D,F  
C,D,F  
Description  
Bottom Front  
Placeholder  
Description  
Code  
B
C
D
E
B=1.0  
C=10  
B16=1.6  
C16=16  
KRY  
TE  
Red/Yellow Lockable Knob  
Right Side  
X
A
B
C
D
E
X
C
D
E
Placeholder  
Spacing Adapter for Self-  
Protected Starters (Type E)  
C,D,  
F
D=100  
E=1000  
D16=160  
E16=1600  
1
1
N.C.  
N.O.  
1 N.O.+1 N.C.  
MT  
STD BusBar Mount, Top  
C,D,F  
2
2
N.O.  
N.C.  
1 N.O.+1 N.C.  
2
N.O.  
N.C.  
K
L
1 N.C. (SC+OL) + 1 N.C. (SC)  
1 N.O. (SC+OL) + 1 N.O. (SC)  
2
1 N.C.+ 1 N.O.  
(SC + OL)  
1 N.O.+1 N.O.(SC+OL)  
R
S
M
1 N.C. (SC + OL)+ 1 N.O. (SC)  
N
Q
1 N.O. (SC + OL) + 1 N.C. (SC)  
1 N.O. (SC)+1 N.C.(SC)  
h
UV and Shunt Trips  
C, D, F Frame  
2nd Code  
1st Code  
Description  
Description  
Left Side  
Undervoltage Trip  
Voltage  
G
J
K
24V AC, 60 Hz  
24V AC, 50 Hz  
D
C
120V AC, 60 Hz  
110V AC, 50 Hz  
H
F
208V AC, 60 Hz  
220…230V AC, 50 Hz  
240V AC, 60Hz  
P
Shunt Trip  
A
T
277V AC, 60 Hz  
N
B
380…400V AC, 50 Hz  
480V AC, 60Hz and 415V AC, 50 Hz  
600V AC, 60Hz  
VC  
M
575V AC, 60Hz and 500V AC, 50 Hz  
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
5
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
Application Diagrams  
Group Installation with MPCBs  
There is only one Branch Circuit Protective Device (BCPD) for the “Group.  
Group installation has been successfully used for many years in the U.S. and Canada. It allows “two or motors or one or more motors and other loads  
to be connected to the same branch-circuit…. The most restrictive part of the conditions specified for Group Installation is the requirement for the  
protection of the conductors for each motor circuit. In the U.S. NEC for 2002, a new rule for the conductor sizing was added for devices that are  
listed and marked “Suitable for use as Tap Conductor Protection.  
Figure 1 shows an example that illustrates installations involving multiple motors with a single BCPD protecting the entire “Group.  
Bulletin 140M Motor Protection Circuit Breakers UL/CSA Listed for Group Installation: conductors from the BCPD to each motor must be  
a minimum of 1/3 the ampacity of the Branch Circuit conductors.  
Bulletin 140M Motor Protection Circuit Breakers UL/CSA Listed for Tap conductor Protection in Group Installations: conductors from  
the BCPD to manual motor controller listed as “…Tap Conductor Protection…” must be minimum of 1/10 the rating or setting of the BCPD.  
Conductors from the controller to the motor must be 125% of the motor FLA.  
Figure 1 - Group Installation with MPCBs  
Branch Circuit Protective Device  
Fuses or  
Circuit Breaker  
Tap Conductor Protection in Group  
Installation:  
Group Installation  
Conductors from BCPD to manual motor  
controller listed as Tap Conductor  
Protection…” must be minimum of 1/10  
the rating or setting of the BCPD  
Single motor taps must be  
1/3 the ampacity of the  
branch circuit conductors  
Branch Circuit Conductors  
Tap Conductor Protection in  
Group Installation:  
Conductors to each motor sized  
normally at 125% of motor FLA  
6
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
Multiple Motor Installation with MPCBs  
Each Motor has an Individual Branch Circuit Protective Device.  
Bulletin 140M Motor Protection Circuit Breakers (MPCBs) are UL/CSA Listed as Type E Manual Self-Protected Combination Motor  
Controllers or UL/CSA Listed as Circuit Breakers. These UL/CSA Listings allow the Bulletin 140M MPCBs to provide the branch-circuit,  
short-circuit protection (as well as overload protection) for each individual motor circuit. Additional short-circuit protection is not required for the  
protection of the individual motor circuits, leaving only the requirement for protection of the feeder circuit conductors by an upstream protective  
device. Figure 2 shows an example that illustrates installations involving multiple motors, each with its own branch-circuit protection (BCPD).  
Figure 2 - Multiple Motor Installation with MPCBs  
Feeder Circuit Conductors  
Bulletin 140M-C…F (Type E Self-Protected  
Combination Motor Controllers) may provide the  
branch-circuit protection for each individual motor  
circuit feeder  
Conductors to each motor sized  
normally at 125% of motor FLA  
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
7
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
Product Selection  
140M-C  
140M-D  
140M-F  
Max. Short Circuit  
Current [kA]  
Max. 3-phase Hp Ratings(1)  
Max. kW, 3-Phase — AC-3(1)  
230V 400/415V 500V  
Rated  
Operational  
Current (Ie) Adjustment  
Motor  
Current  
Magnetic  
Trip Current  
[A]  
Cat. No.  
480V  
(group  
motor)  
400V  
(Icu  
200V 230V 460V 575V  
C-Frame  
690V  
[A]  
Range [A]  
)
0.16  
0.25  
0.4  
0.63  
1
0.10…0.16  
0.16…0.25  
0.25…0.40  
0.40…0.63  
0.63…1.0  
1.0…1.6  
1.6…2.5  
2.5…4.0  
4.0…6.3  
6.3…10  
2.1  
3.3  
5.2  
8.2  
13  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
65  
65  
65  
65  
65  
65  
65  
65  
65  
65  
65  
30  
30  
25  
25  
25  
0.06  
0.09  
0.18  
0.25  
0.37  
0.75  
1.5  
0.02  
0.04  
0.09  
0.18  
0.25  
0.55  
0.75  
1.5  
2.2  
4
0.06  
0.09  
0.12  
0.18  
0.37  
0.75  
1.1  
2.2  
3
0.06  
0.09  
0.18  
0.25  
0.55  
1.1  
1.8  
3
140M-C2E-A16  
140M-C2E-A25  
140M-C2E-A40  
140M-C2E-A63  
140M-C2E-B10  
140M-C2E-B16  
140M-C2E-B25  
140M-C2E-B40  
140M-C2E-B63  
140M-C2E-C10  
140M-C2E-C16  
140M-C2E-C20  
140M-C2E-C25  
140M-C2E-C29  
140M-C2E-C32  
0.25  
0.25 0.33  
0.5 0.75  
1.6  
2.5  
4
21  
0.25 0.33  
0.5 0.75 1.5  
1
1
2
33  
52  
1
1.5  
3
1
2
3
3
6.3  
10  
82  
5
7.5  
5
4
130  
208  
260  
325  
406  
448  
3
10  
15  
20  
20  
25  
30  
2.2  
6.3  
10  
7.5  
13  
16  
10…16  
5
5
10  
4
7.5  
10  
20  
14.5…20  
18…25  
50  
5
7.5  
7.5  
10  
10  
15  
5.5  
11  
17  
25  
15  
7.5  
7.5  
7.5  
20  
5.5  
11  
15  
22  
29  
24…29  
15  
20  
7.5  
13  
18.5  
20  
25  
32  
27…32  
15  
25  
7.5  
15  
25  
D-Frame  
2.5  
4
1.6…2.5  
2.5…4.0  
4.0…6.3  
6.3…10  
10…16  
14.5…20  
18…25  
24…29  
27…32  
33  
52  
100  
100  
100  
100  
100  
100  
65  
65  
65  
65  
65  
65  
65  
30  
30  
30  
0.5 0.75 1.5  
2
0.37  
0.75  
1.5  
2.2  
4
0.75  
1.5  
2.2  
4
1.1  
2.2  
3
1.8  
3
140M-D8E-B25  
140M-D8E-B40  
140M-D8E-B63  
140M-D8E-C10  
140M-D8E-C16  
140M-D8E-C20  
140M-D8E-C25  
140M-D8E-C29  
140M-D8E-C32  
1
1.5  
3
1
2
3
5
3
6.3  
10  
16  
20  
25  
29  
32  
82  
5
4
130  
208  
260  
325  
406  
448  
3
7.5  
10  
15  
20  
20  
25  
10  
15  
20  
20  
25  
30  
6.3  
10  
7.5  
13  
17  
22  
25  
25  
5
5
7.5  
10  
5
7.5  
7.5  
10  
10  
5.5  
5.5  
7.5  
7.5  
11  
7.5  
7.5  
7.5  
11  
15  
50  
13  
18.5  
20  
50  
15  
D-Frame, 140M-D8V…  
1.6  
2.5  
4
1.0…1.6  
1.6…2.5  
2.5…4.0  
4.0…6.3  
6.3…10  
10…16  
14.5…20  
18…25  
24…29  
27…32  
82  
82  
65  
65  
65  
65  
65  
65  
65  
65  
50  
50  
65  
65  
65  
65  
65  
65  
65  
30  
30  
30  
0.25 0.33  
1
0.25  
0.37  
0.75  
1.5  
2.2  
4
0.55  
0.75  
1.5  
2.2  
4
0.75  
1.1  
2.2  
3
140M-D8V-B16  
140M-D8V-B25  
140M-D8V-B40  
140M-D8V-B63  
140M-D8V-C10  
140M-D8V-C16  
140M-D8V-C20  
140M-D8V-C25  
140M-D8V-C29  
140M-D8V-C32  
0.5 0.75 1.5  
82  
1
1.5  
3
1
2
3
5
6.3  
10  
16  
20  
25  
29  
32  
82  
130  
208  
260  
325  
406  
448  
3
7.5  
10  
15  
20  
20  
25  
6.3  
10  
5
5
7.5  
10  
5
7.5  
7.5  
10  
10  
5.5  
5.5  
7.5  
7.5  
11  
7.5  
7.5  
7.5  
11  
15  
13  
18.5  
20  
15  
8
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
Max. Short Circuit  
Current [kA]  
Max. 3-phase Hp Ratings(1)  
Max. kW, 3-Phase — AC-3(1)  
Cat. No.  
Rated  
Operational  
Current (Ie) Adjustment  
Motor  
Current  
Magnetic  
Trip Current  
[A]  
480V  
(group  
400V  
200V 230V 460V 575V  
F-Frame  
230V 400/415V 500V  
690V  
[A]  
Range [A]  
(Icu  
)
motor)  
10  
16  
20  
25  
32  
45  
6.3…10  
10…16  
14.5…20  
18…25  
23…32  
32…45  
130  
208  
260  
325  
416  
585  
100  
100  
100  
100  
65  
65  
65  
65  
65  
65  
65  
3
5
3
5
7.5  
10  
15  
20  
25  
30  
10  
15  
20  
25  
30  
40  
2.2  
4
4
6.3  
10  
11  
15  
20  
30  
7.5  
13  
17  
22  
30  
40  
140M-F8E-C10  
140M-F8E-C16  
140M-F8E-C20  
140M-F8E-C25  
140M-F8E-C32  
140M-F8E-C45  
7.5  
10  
11  
15  
22  
5
7.5  
10  
10  
15  
5.5  
6.3  
7.5  
13  
7.5  
7.5  
10  
65  
(1) Horsepower/kW ratings show are for reference. The final selection of the MPCB depends on the actual motor full load current.  
High Inrush Motor Protection Circuit Breakers  
Short-circuit Protection — High Magnetic Trip (Fixed at 16...21 x Ie)  
Overload Protection — Trip Class 10  
140M-C  
140M-D  
140M-F  
Max. Short Circuit  
Current [kA]  
Max. 3-phase Hp Ratings(1)  
Max. kW, 3-Phase — AC-3(1)  
Rated  
Operational  
Current (Ie)  
[A]  
Magnetic  
Trip  
Current  
[A]  
Motor Current  
Adjustment  
Range [A]  
Cat. No.  
480V  
(group  
motor)  
400V  
(Icu  
200V  
230V  
460V  
575V  
230V 400/415V 500V  
690V  
)
C-Frame  
0.16  
0.25  
0.4  
0.63  
1
0.10…0.16  
0.16…0.25  
0.25…0.40  
0.40…0.63  
0.63…1.0  
1.0…1.6  
1.6…2.5  
2.5…4  
3.3  
5.2  
8.2  
13  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
50  
65  
65  
65  
65  
65  
65  
65  
65  
65  
30  
30  
0.25  
0.5  
1
0.25  
0.5  
1
0.25  
0.33  
0.75  
1
0.02  
0.04  
0.09  
0.18  
0.25  
0.55  
0.75  
1.5  
0.06  
0.09  
0.12  
0.18  
0.37  
0.75  
1.1  
0.06  
0.09  
0.18  
0.25  
0.55  
1.1  
1.8  
3
140M-C2T-A16  
140M-C2T-A25  
140M-C2T-A40  
140M-C2T-A63  
140M-C2T-B10  
140M-C2T-B16  
140M-C2T-B25  
140M-C2T-B40  
140M-C2T-B63  
140M-C2T-C10  
140M-C2T-C16  
0.06  
0.09  
0.18  
0.25  
0.37  
0.75  
1.5  
21  
1.6  
2.5  
4
33  
0.33  
52  
0.75  
1.5  
3
2
82  
1
3
2.2  
6.3  
10  
4…6.3  
130  
208  
260  
1.5  
3
2
5
5
2.2  
3
4
6.3…10  
3
7.5  
10  
10  
15  
2.2  
4
6.3  
7.5  
13  
16  
10…16  
5
5
4
7.5  
10  
D-Frame  
16  
20  
10…16  
260  
325  
100  
65  
65  
30  
5
5
5
10  
15  
15  
20  
4
7.5  
10  
10  
11  
13  
17  
140M-D8T-C16  
140M-D8T-C20  
14.5…20  
7.5  
5.5  
F-Frame  
10  
25  
32  
18…25  
23…32  
416  
585  
65  
65  
65  
65  
7.5  
7.5  
20  
25  
25  
30  
6.3  
7.5  
11  
15  
15  
20  
22  
30  
140M-F8T-C25  
140M-F8T-C32  
10  
(1) Horsepower/kW ratings show are for reference. The final selection of the MPCB depends on the actual motor full load current.  
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
9
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
Screwless Motor Protection Circuit Breakers  
Short-circuit Protection — High Magnetic Trip (Fixed at 16...21 x Ie)  
Overload Protection — Trip Class 10  
140M-RC2  
Max. Short  
Circuit Current  
[kA]  
Max. 3-phase Hp Ratings(1)  
Max. kW, 3-Phase — AC-3(1)  
Rated  
Operational  
Current (Ie)  
[A]  
Magnetic  
Trip  
Current  
[A]  
Motor Current  
Adjustment  
Range [A]  
Cat. No.  
480V  
400V  
(group 200V 230V 460V 575V 230V 400/415V 500V 690V  
motor)  
(Icu  
)
C-Frame  
0.16  
0.25  
0.4  
0.63  
1
0.10…0.16  
0.16…0.25  
0.25…0.40  
0.40…0.63  
0.63…1.0  
1.0…1.6  
1.6…2.5  
2.5…4.0  
4.0…6.3  
6.3…10  
2.1  
3.3  
5.2  
8.2  
13  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
65  
65  
65  
65  
65  
65  
65  
65  
65  
65  
65  
30  
0.25  
0.5  
1
0.33  
0.75  
1
0.25  
0.5  
1
0.25  
0.33  
0.75  
1
0.02  
0.04  
0.09  
0.18  
0.25  
0.55  
0.75  
1.5  
0.06  
0.09  
0.12  
0.18  
0.37  
0.75  
1.1  
0.06  
0.09  
0.18  
0.25  
0.55  
1.1  
140M-RC2E-A16  
140M-RC2E-A25  
140M-RC2E-A40  
140M-RC2E-A63  
140M-RC2E-B10  
140M-RC2E-B16  
140M-RC2E-B25  
140M-RC2E-B40  
140M-RC2E-B63  
140M-RC2E-C10  
140M-RC2E-C16  
0.06  
0.09  
0.18  
0.25  
0.37  
0.75  
1.5  
1.6  
2.5  
4
21  
33  
1.5  
3
2
1.8  
52  
3
2.2  
3.0  
6.3  
10  
82  
1.5  
3
2
5
5
2.2  
3.0  
4.0  
130  
208  
3
7.5  
10  
10  
2.2  
4.0  
6.3  
7.5  
16  
10…16  
5
5
15  
4.0  
7.5  
10  
13  
(1) Horsepower/kW ratings show are for reference. The final selection of the MPCB depends on the actual motor full load current.  
10  
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
Bulletin 140M Motor Circuit Protectors  
Overview  
Motor Circuit Protectors (MCPs) may provide the following protective and control functions.  
Disconnect for Motor Branch Circuit  
Branch-Circuit, Short-Circuit Protection (Magnetic Protection)  
Switching (Manual)  
In North America, electrical codes require that an individual Motor Branch Circuit be protected by a UL/CSA Listed Fuse, Circuit Breaker or Self-  
Protected Combination Motor Controller.  
140M-C, D, and F Frames:  
The 140M-C, D and F frame Motor Circuit Protectors have one UL/CSA Listing - as Manual Motor Controllers (with optional approvals for  
Motor Disconnect and Group Installation). In NEC/CEC Group Installations, these devices must be applied per the appropriate rules, which  
require the use of an upstream Branch-Circuit, Short-Circuit Protective Device (BCPD).  
The 140M-C, D and F Frame Motor Circuit Protectors are also UL/CSA Listed, together with a Bulletin 100C contactor and Bulletin 193  
overload relay, as part of our Bulletin 103T and 107T Self-Protected IEC Combination Starters. These starters are then able to provide all of the  
necessary NEC/CEC requirements for the protection and control of individual Motor Branch Circuits without additional protective devices.  
Standards Compliance and Certifications  
Standards Compliance  
IEC/EN60947-1,-2,-4-1,-5-1  
IEC/EN60204-1  
Certifications  
CE Marked  
CCC  
CSA,C22.2 No.14  
UL508  
cULus Listed (File No. E54612, Guide No. NLRV, NLRV7)  
C-Frame  
D-Frame  
F-Frame  
Current Rating  
0.16…2.5  
A
2.5…32  
A
25…45 A  
Short Circuit Protection  
Standards Compliance:  
CSA22.2, No.14  
UL508 (Group Installation)  
IEC60947-2  
CE  
CCC  
(up to 25 A)  
Accessories  
External Rotary Operator  
Auxiliary Contacts  
Trip Indication Contacts  
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
11  
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
Catalog Number Explanation  
Examplesin this section are not intended to be used for product selection.  
140M  
C
2
N
A63  
KN  
CC  
GJ  
a
b
c
d
e
f
g
h
a
b
c
d
Bulletin Number  
Description  
Motor Circuit Protector  
Frame/Rating  
Code Description  
Interrupting Rating/Breaking Capacity  
Protection Type  
Description  
Fixed Mag only (13 x In)  
Code  
140M  
Code  
Description  
Normal Break  
High Break  
Code  
N
C
D
F
25 A  
2
8
32  
45  
A
A
e
f
g
Current Range  
Code Description Example  
Miscellaneous  
Description  
Auxiliary Trip Contacts  
C, D, F Frames  
2nd  
Code  
KN  
Frame Size  
C,D,F  
A
A=0.10  
A16=0.16  
Black Lockable Knob  
1st Code  
Description  
Bottom Front  
Placeholder  
Description  
Right Side  
Placeholder  
1 N.O.+1 N.C.  
Code  
B
C
D
E
B=1.0  
C=10  
D=100  
E=1000  
B16=1.6  
C16=16  
D16=160  
E16=1600  
KRY Red/Yellow Lockable Knob  
C,D,F  
X
A
B
C
D
E
X
C
Spacing Adapter for Self-  
TE  
C,D,F  
Protected Starters (Type E)  
1
1
N.C.  
N.O.  
MT  
STD BusBar Mount, Top  
C,D,F  
D
E
2
2
N.O.  
N.C.  
1 N.O.+1 N.C.  
2
N.O.  
N.C.  
K
L
1 N.C. (SC+OL) + 1 N.C. (SC)  
1 N.O. (SC+OL) + 1 N.O. (SC)  
1 N.C. (SC + OL)+ 1 N.O. (SC)  
1 N.O. (SC + OL) + 1 N.C. (SC)  
1 N.O. (SC)+1 N.C.(SC)  
2
R
S
1 N.C.+ 1 N.O. (SC + OL)  
1 N.O.+1 N.O.(SC+OL)  
M
N
Q
h
UV and Shunt Trips  
C, D, F Frame  
2nd Code  
1st Code  
Description  
Description  
Left Side  
Undervoltage Trip  
Voltage  
G
J
K
24V AC, 60 Hz  
24V AC, 50 Hz  
D
C
120V AC, 60 Hz  
110V AC, 50 Hz  
H
F
208V AC, 60 Hz  
220…230V AC, 50 Hz  
240V AC, 60Hz  
P
Shunt Trip  
A
T
277V AC, 60 Hz  
N
B
380…400V AC, 50 Hz  
480V AC, 60Hz and415V AC, 50 Hz  
600V AC, 60Hz  
VC  
M
575V AC, 60Hz and500V AC, 50 Hz  
12  
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
Application Diagrams  
Group Installation with MCPs  
There is only one Branch Circuit Protective Device (BCPD) for the “Group.  
Group installation has been successfully used for many years in the U.S. and Canada. It allows “two or motors or one or more motors and other loads  
to be connected to the same branch-circuit…. The most restrictive part of the conditions specified for Group Installation is the requirement for the  
protection of the conductors for each motor circuit.  
Figure 3 shows an example that illustrates installations involving multiple motors with a single BCPD protecting the entire “Group.  
Bulletin 140M Motor Circuit Protectors UL/CSA Listed for Group Installation: conductors from the BCPD to each motor must be a minimum  
of 1/3 the ampacity of the Branch Circuit conductors. MCPs do not provide thermal protection, so a separate overload relay must be used. Because  
of this, MCPs cannot be UL/CSA Listed for Tap Conductor Protection in group installations.  
Figure 3 - Group Installation with MCPs  
Branch Circuit Protective Device  
Fuses or  
Circuit Breaker  
Group Installation  
Single motor taps must be  
1/3 the ampacity of the  
Branch Circuit Conductors  
branch circuit conductors  
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
13  
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
Multiple Motor Installation with MCPs  
Each Motor has an Individual Branch Circuit Protective Device.  
Bulletin 140M Motor Circuit Protectors (MCPs) are UL/CSA Listed as part of a Combination Motor Controllers or a Self-Protected  
Combination Motor Controller consisting of a 140M Motor Circuit Protector, a 100-C Contactor, and a 193 Overload Relay. These UL/CSA  
Listings allow the Bulletin 140M MCPs to provide the branch-circuit, short-circuit protection for each individual motor circuit. Additional short-  
circuit protection is not required for the protection of the individual motor circuits, leaving only the requirement for protection of the feeder circuit  
conductors by an upstream protective device. Figure 4 shows an example that illustrates installations involving multiple motors, each with its own  
branch-circuit protection (BCPD).  
Figure 4 - Multiple Motor Installation with MCPs  
Feeder Circuit Conductors  
Bulletin 140M-C…F (UL/CSA Listed Manual Motor  
Controllers) may provide the branch-circuit protection  
for each individual motor circuit feeder as part of a  
Listed self-protected combination motor controller  
Conductors to each motor sized  
normally at 125% of motor FLA  
14  
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
Product Selection  
For trip Class 10 motor applications  
140M-C  
140M-D  
140M-F  
Ultimate Interrupting  
Current [kA]  
Rated  
Operational  
Current (Ie)  
[A](1)  
Max. 3-phase Hp Ratings(2)  
Max. kW, 3-Phase — AC-3(2)  
Magnetic  
Trip Current  
[A]  
Cat. No.  
400V  
(Icu  
480V  
(group motor)  
200V 230V 460V 575V 230V  
C-Frame  
400/415V  
500V 690V  
)
0.16  
0.25  
0.4  
0.63  
1
2.1  
3.3  
5.2  
8.2  
13  
100  
100  
100  
100  
100  
100  
100  
65  
65  
65  
65  
65  
65  
65  
0.25  
0.5  
0.25  
0.33  
0.75  
1
0.02  
0.04  
0.09  
0.18  
0.25  
0.55  
0.75  
0.06  
0.09  
0.12  
0.18  
0.37  
0.75  
1.1  
0.06 140M-C2N-A16  
0.09 140M-C2N-A25  
0.18 140M-C2N-A40  
0.25 140M-C2N-A63  
0.55 140M-C2N-B10  
0.06  
0.09  
0.18  
0.25  
0.37  
1.6  
2.5  
21  
0.25 0.33  
0.5 0.75  
1
1.1  
1.8  
140M-C2N-B16  
140M-C2N-B25  
33  
1.5  
2
D-Frame  
1.5  
2.5  
4
33  
52  
100  
100  
100  
100  
100  
65  
65  
65  
65  
65  
65  
30  
30  
0.5 0.75  
2
3
0.37  
0.75  
1.5  
2.2  
4
0.75  
1.5  
2.2  
4
1.1  
2.2  
3
1.8  
3
140M-D8N-B25  
140M-D8N-B40  
140M-D8N-B63  
140M-D8N-C10  
140M-D8N-C16  
140M-D8N-C25  
140M-D8N-C32  
1
1.5  
3
1
2
3
5
3
6.3  
10  
16  
25  
32  
82  
5
5
4
130  
208  
325  
448  
7.5  
10  
15  
20  
30  
6.3  
10  
15  
20  
7.5  
13  
22  
25  
5
10  
7.5  
11  
7.5 7.5  
7.5 10  
20  
5.5  
7.5  
50  
25  
15  
F-Frame  
20  
25  
32  
45  
325  
416  
585  
100  
65  
65  
65  
65  
7.5 10  
7.5 10  
10 15  
25  
30  
40  
6.3  
7.5  
13  
11  
15  
22  
15  
20  
30  
22  
30  
40  
140M-F8N-C25  
140M-F8N-C32  
140M-F8N-C45  
25  
65  
30  
(1) In applications with 140M-C_N, 140M-D_N and 140M-F_N as the short circuit protection device of heavy duty starting motors, the rated operational current Ie of the above devices must be over-dimensioned with  
following factors:  
Class 10 = 1.00  
Class 15 = 1.22  
Class 20 = 1.42  
Class 25 = 1.58  
Class 30 = 1.73  
(2) Horsepower/kW ratings show are for reference. The final selection of the MCP depends on the actual motor full load current.  
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
15  
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
Notes:  
16  
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
Accessories  
Auxiliary Contacts  
Operator Position(1)  
OFF ON Tripped  
Term.  
Contact  
Connection  
Description  
For Use With  
Cat. No.  
No. Description Diagram(2)  
O
X
X
O
X
13-14  
11-12  
N.O. Aux  
N.C. Aux  
140M-C-AFA10  
140M-C-AFA01  
140M-C, D, F;  
140U-D (UL489  
only in  
combination with  
140M-C-AFC)  
O
Front-Mounted Auxiliary Contact  
1-pole or 2-pole  
O
X
O
O
X
X
X
O
X
X
O
O
O
X
O
O
X
X
13-14  
21-22  
13-14  
23-24  
11-12  
21-22  
N.O. Aux  
N.C. Aux  
N.O. Aux  
N.O. Aux  
N.C. Aux  
N.C. Aux  
13 21  
14 22  
No additional space required  
Only one per device  
140M-C-AFA11  
140M-C-AFA20  
140M-C, D, F;  
140U-D (UL489  
only in  
combination with  
140M-C-AFC)  
140M-C-AFA02  
140M-C-ASA20  
140M-C-ASA02  
140M-C-ASA11  
O
O
X
X
X
O
O
O
X
33-34  
43-44  
31-32  
N.O. Aux  
N.O. Aux  
N.C. Aux  
140M-C, D, F  
140M-C, D, F  
140M-C, D, F  
Right Side-Mounted Auxiliary Contact  
31 41  
32 42  
2-pole  
Adds 9 mm to the width of the device  
Two per device  
X
O
X
O
X
O
X
O
X
41-42  
33-34  
41-42  
N.C. Aux  
N.O. Aux  
N.C. Aux  
(1) X = Contact Closed; O = Contact Open  
(2) Connection Diagram Reference:  
140M Operator  
Overload (thermal) Trip  
Short-Circuit (magnetic) Trip  
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
17  
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
Trip Contacts  
Operator Position(1)  
OFF  
ON Tripped  
Term.  
No.  
Contact  
Description  
Connection  
Diagram(2)  
Description  
For Use With  
Cat. No.  
O
O
X
X
O
O
O
O
X
X
X
13-14  
N.O. Aux  
N.O. Trip  
140M-C-AFAR10A10  
140M-C-AFAR10A01  
140M-C, D, F;  
140U-D  
(UL489 only in  
combination with  
140M-C-AFC)  
27-28 (short-circuit and  
overload)  
Front-Mounted Trip Contact  
2-pole  
Indicates tripping of device  
No additional space required  
11-12  
N.C. Aux  
N.O. Trip  
11 27  
O
27-28 (short-circuit and  
overload)  
12 28  
N.O. Trip  
57-58 (short-circuit and  
overload)  
O
O
O
X
X
O
X
O
O
O
X
X
O
X
X
X
X
O
O
X
O
57 67  
58 68  
140M-C, D, F  
140M-C, D, F  
140M-C, D, F  
140M-C-ASAR10M10  
140M-C-ASAR10M01  
140M-C-ASAR01M10  
I>>  
N.O. Trip  
67-68  
(short-circuit)  
N.O. Trip  
57-58 (short-circuit and  
overload)  
57 65  
58 66  
I>>  
I >>  
I >>  
Right-Side Mounted Trip Contact  
N.C. Trip  
65-66  
2-pole  
(short-circuit)  
Indicates tripping of the device  
Adds 9 mm to the width of the  
device  
N.C. Trip  
55-56 (short-circuit and  
overload)  
55 67  
56 68  
One only per device  
A right-side mounted auxiliary  
contact may be tandem  
mounted on top of this trip  
contact  
N.O. Trip  
67-68  
(short-circuit)  
N.C. Trip  
55-56 (short-circuit and  
overload)  
65  
66  
55  
56  
140M-C, D, F  
140M-C, D, F  
140M-C-ASAR01M01  
140M-C-ASAM11  
N.C. Trip  
65-66  
X
O
X
X
O
X
O
X
O
(short-circuit)  
N.O. Trip  
77-78  
(short-circuit)  
77 65  
78 66  
N.C. Trip  
65-66  
I >>  
(short-circuit)  
(1) X = Contact Closed; O = Contact Open  
(2) Connection Diagram Reference:  
140M Operator  
Overload (thermal) Trip  
Short-Circuit (magnetic) Trip  
18  
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
Auxiliary and Trip Contacts  
Description  
Operator Position(1)  
OFF  
ON  
Tripped  
Term.  
No.  
Contact  
Description  
Connection  
Diagram(2)  
For Use With  
Cat. No.  
13  
O
X
X
O
X
13-14  
11-12  
N.O. Aux  
140M-RC-AFA10  
140M-RC-AFA01  
14  
I >>  
140M-C, D, F;  
140M-RC  
11  
Front-Mounted Auxiliary  
O
N.C. Aux  
12  
Contact  
I >>  
1-pole or 2-pole  
No additional space  
required  
O
X
X
O
X
X
X
O
O
O
O
X
O
O
O
X
X
X
13-14  
21-22  
13-14  
23-24  
13-14  
N.O. Aux  
N.C. Aux  
N.O. Aux  
N.O. Aux  
13 21  
140M-RC-AFA11  
- Only 1 per device  
14 22  
140M-C, D, F;  
140M-RC  
O
O
O
O
X
13 23  
14 24  
140M-RC-AFA20  
I >>  
N.O. Aux  
N.O. Trip  
13 27  
Front-Mounted Trip Contact  
140M-RC-AFAR10A01  
140M-RC-AFAR10A10  
27-28 (short-circuit and  
overload)  
2-pole  
I >>  
14 28  
11 27  
Indicates tripping of  
device  
140M-C, D, F;  
140M-RC  
11-12  
N.C. Aux  
N.O. Trip  
No additional space  
required  
O
27-28 (short-circuit and  
overload)  
I >>  
12 28  
(1) X = Contact Closed; O = Contact Open  
(2) Connection Diagram Reference:  
140M Operator  
Overload (thermal) Trip  
Short-Circuit (magnetic) Trip  
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
19  
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
Undervoltage and Shunt Tip Units  
Description  
Connection Diagram(1)  
Trip Rating  
24V, 60 Hz  
For Use With  
Cat. No.  
140M-C-UXJ  
140M-C-UXK  
140M-C-UXD  
140M-C-UXC  
140M-C-UXH  
140M-C-UXF  
140M-C-UXA  
140M-C-UXT  
140M-C-UXN  
140M-C-UXB  
140M-C-UXM  
140M-C-UXVC  
140M-C-UCJ  
140M-C-UCK  
140M-C-UCD  
140M-C-UCC  
140M-C-UCH  
140M-C-UCF  
140M-C-UCA  
140M-C-UCT  
140M-C-UCN  
140M-C-UCB  
140M-C-UCM  
140M-C-UCVC  
140M-C-SNJ  
140M-C-SNK  
140M-C-SND  
140M-C-SNH  
140M-C-SNF  
140M-C-SNA  
140M-C-SNT  
140M-C-SNN  
140M-C-SNB  
140M-C-SNM  
140M-C-SNVC  
140M-C-SNZJ  
24V, 50 Hz  
120V, 60 Hz  
110V, 50 Hz  
Undervoltage Trip  
208V, 60 Hz  
D1  
Left-side mounted  
220…230V, 50 Hz  
240…260V, 60 Hz  
277V, 60 Hz  
Adds 18 mm to the width of the  
device  
Automatically trips MPCB/MCP  
when voltage falls below 35…70%  
U<  
140M-C, D, F; 140U-D  
D2  
I >>  
380…400V, 50 Hz  
480V, 60 Hz/415V, 50 Hz  
575V, 60 Hz/500V, 50 Hz  
600V, 60 Hz  
24V, 60 Hz  
24V, 50 Hz  
120V, 60 Hz  
110V, 50 Hz  
D1 07  
Undervoltage Trip  
208V, 60 Hz  
Left-side mounted  
2 early make contacts integrated  
Adds 18 mm to the width of the  
device  
220…230V, 50 Hz  
240…260V, 60 Hz  
277V, 60 Hz  
U<  
140M-C, D, F  
D2 08  
I >  
Automatically trips MPCB/MCP  
when voltage falls below 35…70%  
380…400V, 50 Hz  
480V, 60 Hz/415V, 50 Hz  
575V, 60 Hz/500V, 50 Hz  
600V, 60 Hz  
24V, 60 Hz  
24V, 50 Hz  
110V, 50 Hz/120V, 60 Hz  
208V, 60 Hz  
Shunt Trip  
Left-side mounted  
C1  
C2  
220…230V, 50 Hz  
240…260V, 60 Hz  
277V, 60 Hz  
Adds 18 mm to the width of the  
device  
140M-C, D, F; 140U-D  
Provides remote tripping of the  
MPCB/MCP  
Maximum on time for DC operated  
devices: 5 sec.  
I >>  
380…400V, 50 Hz  
480V, 60 Hz/415V, 50 Hz  
575V, 60 Hz/500V, 50 Hz  
600V, 60 Hz  
24V DC  
(1) Connection Diagram Reference:  
140M Operator  
Overload (thermal) Trip  
Short-Circuit (magnetic) Trip  
20  
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
Additional Accessories  
Description  
For Use With  
Cat. No.  
Anti-Tamper Shield  
Provides protection against inadvertent adjustment of the current setting  
Must be ordered in multiples of 10 (10 pcs/pkg)  
140M-C, D, F  
140M-C-CA  
Black  
140M-C-KN1  
140M-C-KRY1  
Lockable Twist Knob  
140M-C, D, F  
140U- D  
For one padlock 5 mm (3/16 in.) diameter shackle  
Can be locked in OFF position  
Red/Yellow  
Locking Tag  
140M-C-KN1  
140M- C-KRY1  
Padlock attachment to the lockable handles  
140M-C-M3  
Up to three padlocks 4…8 mm (5/16 in.) diameter shackle  
Door Coupling Handle  
For 3 padlocks 4…8 mm (5/16 in.) in diameter  
IP66 Protection/Type 1, 4, 4X, 12 Interlock override capability  
Can be modified for locking in ON position  
Black  
140M-C-DN66  
Ships with coupling — order extension shaft and legend plate separately  
Mounting depth (front of DIN Rail to front of enclosure door):  
140M-C: 105.5 mm 5 mm (4.15 in. 3/16 in.)  
140M-C, D, F  
140U- D  
140M-D: 114.5 mm 5 mm (4.5 in. 3/16 in.)  
140M-F: 137.1 mm 5 mm (5.4 in. 3/16 in.)  
140U-D: 114.5mm 5mm (4.5 in. 3/16 in.) ser E or later handles only  
Red/Yellow  
140M-C-DRY66  
140M-C-DS  
Extension Shaft  
Cut to required length for mounting depth (front of DIN Rail to front of enclosure door):  
140M-C: 117…338 mm (4.6.…13.3 in.)  
140M-C-DN66,  
140M-C-DRY66,  
140M-D: 126…347 mm (5.0.…13.7 in.)  
140M-F: 149…369 mm (5.9.…14.5 in.)  
140U-D: 126...347 mm (5.0...13.7 in.) ser E or later handles only  
Extension Shaft (Extended Length)  
Cut to required length for mounting depth (front of DIN Rail to front of enclosure door):  
140M-C: 117…488 mm (4.6…19.2 in.)  
140M-C-DN66,  
140M-C-DRY66  
140M-C-DSL  
140M-D: 126…497 mm (5.0…19.6 in.)  
140M-F: 149…519 mm (5.9…20.4 in.)  
140U-D: 126...497 mm (5.0...19.6 in.) ser E or later handles only  
Black  
140M-SB  
140M-SY  
140M-S1  
140M-S2  
Door Coupling Handle  
Type 3, 3R, 4, 4X, 12 (IP66)  
For up to 2 padlocks  
140M-C, D, F  
140U- D  
Red/Yellow  
Fits in 30.5 mm cutout  
Requires 140M-C-DNC coupler  
12 in. (30.48 cm)  
21 in. (53.34 cm)  
Extension Shaft  
140M-SB,  
140M-SY  
Cut to required length for mounting depth (front of DIN Rail to front of enclosure  
door)  
140M-C, D, F  
140U- D  
Coupler  
140M-C-DNC  
140M-C-SHS  
Included with Cat. Nos. 140M-C-DN66 and 140M-C-DRY66  
Extension Shaft Support  
Provides consistent alignment of the 140M-C-DS and 140M-C-DSL shafts with the 140M-C-DN66 or 140M-  
C-DRY66 door coupling handles.  
140M-C, D, F  
140U- D  
It is recommended for shaft lengths >200 mm.  
Snaps on the right side of the 140M-C, -D, -F or 140U-D and allows for the addition of one side-mounted  
auxiliary contact.  
Width 9 mm.  
For use with screw-mounted or hat rail mounted devices.  
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
21  
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
Description  
For Use With  
Cat. No.  
Marking:  
"Hauptschalter" and 140-CDN66  
"Main Switch"  
140M-C-DFCN  
Legend Plate  
Marking: "Not-Aus"  
140-CDRY66  
140M-C-DFCRY  
198E-AYTG2  
and "Emergency Off"  
Black Handle  
140M-C  
140M-C  
IP65 Non-Metallic Enclosure  
Knockouts for M20 and M25 fittings  
Suitable for flexible cable with internal ground wire or conduit when externally  
grounded around the outside of the enclosure (no UL/CSA approval)  
Red/Yellow Handle  
198E-AYTJ2  
Screw Adapter  
140M-C, D, F  
140U- D  
For screw arrangement of a motor protection circuit breaker  
Must be ordered in multiples of 10 (10 pcs/pkg)  
140M-C-N45  
Description  
For Use With  
Cat. No.  
ECO Connecting Module — 12 A  
For DOL and reversing starters  
Eco-starters mount on single DIN Rail (140M on DIN Rail)  
Electrical and mechanical interconnection of 140M and 100-K contactors  
140M-C to 100-K  
140M-C-PEK12  
ECO Connecting Modules — 25 A  
140M-C to 100-C09…C23  
140M-D to 100-C09…C23  
140M-C-PEC23  
140M-D-PEC23  
Eco-starters mount on single DIN Rail (140M on DIN Rail)  
Electrical and mechanical interconnection of 140M MPCB and 100-C (with AC coils or 24V  
DC electronic coils) contactors  
ECO Connecting Modules — 25 A  
Eco-starters mount on single DIN Rail (100-C on DIN Rail)  
140M-C, 140M-D to  
100-C09…C23  
140M-C-PEC23A  
Electrical and mechanical interconnection of 140M MPCB and 100-C (with conventional DC  
coils)  
140M-C to 100-C09…C23  
140M-D to 100-C09…C23  
140M-D to 100-C30…C37  
140M-F to 100-C30…C37  
140M-F to 100-C43  
140M-C-PNC23  
140M-D-PNC23  
140M-D-PNC37  
140M-F-PNC37  
140M-F-PNC43  
140M-C-PSC23  
140M-F-PSC43  
140M-C-TE1  
Connecting Modules — 25 and 45 A  
Contactor and MPCB MUST BE mounted separately on (2) DIN Rails Electrical  
interconnection of 140M and 100-C (with AC coils)  
140M-C, -D to 100-C09…C23  
140M-D, -F to 100-C30…C43  
140M-C, -D  
Coil Modules — 25 A and 45 A  
For use with Bulletin 103T/107T 3-component starters  
Spacing Adapter  
Required for self-protected combination motor controller (Type E) applications of Bul.  
140M-C, -D, and -F MPCBs. Not for use with bus bars.  
140M-F  
140M-F-TE  
22  
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
Description  
For Use With  
Cat. No.  
140M-C  
140M-C-WBE  
Feeder Block for Compact Busbar  
Supply of compact busbars Increases terminal capacity  
140M-F  
140M-F-WBE  
140M-C-WTN  
Feeder Terminal for Compact Busbar  
For supply of compact busbars  
Top feed — overlaps compact busbar  
Meets IEC spacing requirements  
140M-C, -D  
140M-C, -D  
140M-F  
140M-C-WTEN  
140M-F-WTE  
Feeder Terminal for Compact Busbar  
For supply of compact busbars  
Top feed — overlaps compact busbar  
Meets UL Type E spacing requirements  
2 connections  
3 connections  
4 connections  
5 connections  
2 connections  
3 connections  
4 connections  
5 connections  
140M-C-W452N  
140M-C-W453N  
140M-C-W454N  
140M-C-W455N  
140M-C-W542N  
140M-C-W543N  
140M-C-W544N  
140M-C-W545N  
140M-F-W542  
140M-F-W543  
140M-F-W544  
140M-F-W632  
140M-F-W633  
140M-F-W634  
140M-C-WSN  
Three-phase Compact Busbar for 32 A Motor Protection Circuit Breakers  
— 64 A Max. Continuous Current  
140M-C, -D  
140M-C, -D  
45 mm spacing  
For use with front-mounted auxiliary contact  
Three-phase Compact Busbar for 32 A Motor Protection Circuit Breakers  
— 64 A Max. Continuous Current  
54 mm spacing  
For use with side-mounted auxiliary contact  
Three-phase Compact Busbar for 45 A Motor Protection Circuit Breakers 2 connections  
— 115 A Max. Continuous Current  
3 connections  
140M-F  
140M-F  
54 mm spacing  
For use with front-mounted auxiliary contact  
4 connections  
Three-phase Compact Busbar for 45 A Motor Protection Circuit Breakers 2 connections  
— 115 A Max. Continuous Current  
3 connections  
63 mm spacing  
For use with side-mounted auxiliary contact  
4 connections  
140M-C, -D  
140M-F  
Terminal Cover  
For covering of unused compact bus bar terminals IP2X finger protection  
Must be ordered in multiples of 10  
(10 pcs/pkg)  
140M-F-WS  
Top Hat Rail Adapter — 10 mm  
Adjusts the depth of the 140M-C to the 140M-D  
Allows the use of compact busbars across both frame sizes  
Must be ordered in multiples of 10  
140M-C  
140M-D, -F  
140M-C, -D, -F  
140-KBH2  
(10 pcs/pkg)  
DIN (#3) symmetrical hat rail  
35 x 7.5 x 1 m  
(10 pcs/pkg)  
199-DR1  
DIN (#3) Symmetrical Rail  
35 mm x 15 mm x 1 m long  
Top Hat Rail (DIN #3 Symmetrical Rail)  
(5 pcs/pkg)  
1492-DR9  
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
23  
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
Notes:  
24  
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
Specifications  
Application Ratings  
UL/CSA Listed Application Ratings, Motor Protection Circuit Breaker Only  
UL 508 — Manual Motor Controller  
UL 508 Self-Protected (Type E)  
Combination Motor Controller  
Group Motor Installation  
Motor Disconnect  
Tap Conductor Protection  
Cat. No.  
Max. Fuse or Max. Short Circuit Current  
Max. Short Circuit Current  
[kA]  
Max. Short Circuit Current  
[kA]  
Max. Short Circuit Current  
[kA]  
C.B. per NEC  
[kA]  
480V  
600V  
480V  
C-Frame  
600V  
480Y/277V(1) 600Y/347V(1) 480Y/277V(1) 600Y/347V(1)  
140M-C2E-A16  
140M-C2E-A25  
140M-C2E-A40  
140M-C2E-A63  
140M-C2E-B10  
140M-C2E-B16  
140M-C2E-B25  
140M-C2E-B40  
140M-C2E-B63  
140M-C2E-C10  
140M-C2E-C16  
140M-C2E-C20  
140M-C2E-C25  
140M-C2E-C29  
140M-C2E-C32  
140M-C2T-A16  
140M-C2T-A25  
140M-C2T-A40  
140M-C2T-A63  
140M-C2T-B10  
140M-C2T-B16  
140M-C2T-B25  
140M-C2T-B40  
140M-C2T-B63  
140M-C2T-C10  
140M-C2T-C16  
450  
450  
450  
450  
450  
450  
450  
450  
450  
450  
450  
450  
450  
450  
450  
450  
450  
450  
450  
450  
450  
450  
450  
450  
450  
450  
65  
65  
65  
65  
65  
65  
65  
65  
65  
65  
30  
30  
25  
25  
25  
65  
65  
65  
65  
65  
65  
65  
65  
65  
30  
30  
47  
47  
47  
47  
47  
47  
30  
25  
30  
30  
30  
30  
10  
5
65  
47  
47  
47  
47  
47  
47  
30  
25  
30  
30  
30  
10  
5
65  
65  
65  
65  
65  
65  
65  
65  
65  
65  
30  
10  
65  
65  
65  
65  
65  
65  
65  
65  
65  
30  
10  
47  
47  
65  
65  
65  
65  
65  
65  
65  
65  
65  
65  
30  
10  
65  
65  
65  
65  
65  
65  
65  
65  
65  
30  
10  
47  
47  
65  
65  
47  
47  
65  
47  
47  
65  
47  
47  
65  
47  
47  
65  
30  
30  
65  
25  
25  
65  
47  
47  
65  
30  
10  
10  
10  
47  
47  
47  
47  
47  
47  
25  
30  
30  
30  
10  
5
10  
47  
47  
47  
47  
47  
47  
25  
30  
30  
30  
30  
65  
65  
47  
47  
65  
47  
47  
65  
47  
47  
65  
47  
47  
65  
30  
30  
65  
25  
25  
65  
65  
30  
10  
D-Frame (D8E)  
140M-D8E-B25  
140M-D8E-B40  
140M-D8E-B63  
140M-D8E-C10  
140M-D8E-C16  
140M-D8E-C20  
140M-D8E-C25  
140M-D8E-C29  
140M-D8E-C32  
450  
450  
450  
450  
450  
450  
450  
450  
450  
65  
65  
65  
65  
65  
65  
30  
30  
30  
30  
30  
30  
30  
30  
30  
30  
30  
30  
65  
65  
65  
65  
65  
65  
30  
30  
30  
30  
30  
30  
30  
30  
30  
30  
18  
18  
65  
65  
65  
65  
65  
65  
30  
30  
30  
65  
65  
65  
65  
65  
65  
30  
30  
30  
30  
30  
30  
30  
30  
30  
(1) For full voltage (delta) ratings above 277V or 347V, follow the NEC or CEC rules for group motor applications.  
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
25  
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
UL 508 — Manual Motor Controller  
UL 508 Self-Protected (Type E)  
Combination Motor Controller  
Group Motor Installation  
Motor Disconnect  
Tap Conductor Protection  
Cat. No.  
Max. Fuse or Max. Short Circuit Current  
Max. Short Circuit Current  
[kA]  
Max. Short Circuit Current  
[kA]  
Max. Short Circuit Current  
[kA]  
C.B. per NEC  
[kA]  
480V  
600V  
480V  
600V  
480Y/277V(1) 600Y/347V(1) 480Y/277V(1) 600Y/347V(1)  
D-Frame (D8V, D8T)  
140M-D8T-C16  
140M-D8T-C20  
140M-D8V-B16  
140M-D8V-B25  
140M-D8V-B40  
140M-D8V-B63  
140M-D8V-C10  
140M-D8V-C16  
140M-D8V-C20  
140M-D8V-C25  
140M-D8V-C29  
140M-D8V-C32  
450  
450  
450  
450  
450  
450  
450  
450  
450  
450  
450  
450  
65  
30  
65  
65  
65  
65  
65  
65  
65  
30  
30  
30  
30  
30  
65  
30  
65  
65  
65  
65  
65  
65  
65  
30  
30  
30  
30  
65  
30  
65  
65  
65  
65  
65  
65  
65  
30  
30  
65  
30  
65  
65  
65  
65  
65  
65  
65  
30  
30  
30  
F-Frame  
140M-F8E-C10  
140M-F8E-C16  
140M-F8E-C20  
140M-F8E-C25  
140M-F8E-C32  
140M-F8E-C45  
140M-F8T-C25  
140M-F8T-C32  
600  
600  
600  
600  
600  
600  
600  
600  
65  
65  
65  
65  
65  
65  
65  
65  
30  
30  
30  
30  
30  
18  
30  
18  
65  
65  
65  
65  
65  
65  
65  
65  
30  
30  
30  
30  
30  
18  
30  
18  
65  
65  
65  
65  
65  
65  
65  
65  
30  
30  
30  
30  
30  
30  
18  
65  
65  
65  
65  
65  
65  
65  
65  
30  
30  
30  
30  
30  
30  
18  
(1) For full voltage (delta) ratings above 277V or 347V, follow the NEC or CEC rules for group motor applications.  
26  
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
UL Listed Application Ratings, Motor Circuit Protector Only  
(Separate Overload Protection Required)  
UL 508 — Manual Motor Controller  
Group Motor Installation  
Max. Short Circuit Current [kA]  
Motor Disconnect  
Max. Short Circuit Current [kA]  
Cat. No.  
Max. Fuse or C.B. per NEC  
480V  
600V  
480V  
600V  
C-Frame  
D-Frame  
F-Frame  
140M-C2N-A16  
140M-C2N-A25  
140M-C2N-A40  
140M-C2N-A63  
140M-C2N-B10  
140M-C2N-B16  
140M-C2N-B25  
450  
450  
450  
450  
450  
450  
450  
65  
65  
65  
65  
65  
65  
65  
47  
47  
47  
47  
47  
47  
30  
65  
65  
65  
65  
65  
65  
65  
47  
47  
47  
47  
47  
47  
30  
140M-D8N-B25  
140M-D8N-B40  
140M-D8N-B63  
140M-D8N-C10  
140M-D8N-C16  
140M-D8N-C25  
140M-D8N-C32  
450  
450  
450  
450  
450  
450  
450  
65  
65  
65  
65  
65  
30  
30  
30  
30  
30  
30  
30  
30  
30  
65  
65  
65  
65  
65  
30  
30  
30  
30  
30  
30  
30  
30  
18  
140M-F8N-C25  
140M-F8N-C32  
140M-F8N-C45  
600  
600  
600  
65  
65  
65  
30  
30  
18  
65  
65  
65  
30  
30  
18  
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
27  
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
UL Listed Application Ratings - Motor Protection Circuit Breakers with Bulletin 100-K Contactors  
UL 508 — Manual Motor Controller  
UL508 Type F Combination Motor Controller  
Group Motor Installation  
Motor Disconnect  
Minimum  
Contactor  
Size  
Cat. No.  
Max. Fuse or  
C.B. per NEC  
Max. Short Circuit Current [kA] Max. Short Circuit Current [kA] Minimum Max. Short Circuit Current [kA]  
Contactor  
480V  
600V  
480V  
600V  
480Y/277V(1) 600Y/347V(1)  
Size  
C-Frame  
140M-C2E-A16  
140M-C2E-A25  
140M-C2E-A40  
140M-C2E-A63  
140M-C2E-B10  
140M-C2E-B16  
140M-C2E-B25  
140M-C2E-B40  
140M-C2E-B63  
140M-C2E-C10  
140M-C2E-C16  
450  
450  
450  
450  
450  
450  
450  
450  
450  
450  
450  
100-K05  
100-K05  
100-K05  
100-K05  
100-K05  
100-K05  
100-K05  
100-K05  
100-K05  
100-K09  
100-K12  
65  
65  
65  
65  
65  
65  
65  
65  
65  
65  
30  
47  
47  
47  
47  
47  
47  
30  
30  
30  
30  
30  
65  
65  
65  
65  
65  
65  
65  
65  
65  
65  
30  
47  
47  
47  
47  
47  
47  
30  
30  
30  
30  
30  
100-K05  
100-K05  
100-K05  
100-K05  
100-K05  
100-K05  
100-K05  
100-K05  
100-K05  
100-K09  
100-K12  
65  
65  
65  
65  
65  
65  
65  
65  
65  
65  
30  
47  
47  
47  
47  
47  
47  
30  
30  
D-Frame  
140M-D8E-B25  
140M-D8E-B40  
140M-D8E-B63  
140M-D8E-C10  
140M-D8E-C16  
450  
450  
450  
450  
450  
100-K05  
100-K05  
100-K05  
100-K09  
100-K12  
65  
65  
65  
65  
65  
30  
30  
30  
30  
30  
65  
65  
65  
65  
65  
30  
30  
30  
30  
30  
100-K05  
100-K05  
100-K05  
100-K09  
100-K12  
65  
65  
65  
65  
65  
30  
30  
30  
30  
30  
(1) For full voltage (delta) ratings above 277V or 347V, follow the NEC or CEC rules for group motor applications.  
28  
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
UL Listed Application Ratings - Motor Protection Circuit Breakers with Bulletin 100-C Contactors  
UL 508 — Manual Motor Controller  
Group Motor  
UL508 Type F Combination Motor  
Controller  
UL508 Type E Self-Protected  
Combination Motor Controller  
Motor Disconnect  
Installation  
Max. Fuse Minimum  
or C.B. per Contactor  
Cat. No.  
Max. Short Circuit  
Current [kA]  
Max. Short Circuit  
Current [kA]  
Max. Short Circuit  
Current [kA]  
Max. Short Circuit  
Current [kA]  
Minimum  
Contactor  
Size  
Minimum  
Contactor  
Size  
NEC  
Size  
480Y/  
600Y/  
480Y/  
600Y/  
480V  
600V  
480V  
600V  
277V(1)  
347V(1)  
277V(1)  
347V(1)  
C-Frame  
140M-C2E-A16  
140M-C2E-A25  
140M-C2E-A40  
140M-C2E-A63  
140M-C2E-B10  
140M-C2E-B16  
140M-C2E-B25  
140M-C2E-B40  
140M-C2E-B63  
140M-C2E-C10  
140M-C2E-C16  
140M-C2E-C20  
450  
450  
450  
450  
450  
450  
450  
450  
450  
450  
450  
450  
450  
450  
450  
450  
100-C09  
100-C09  
100-C09  
100-C09  
100-C09  
100-C09  
100-C09  
100-C09  
100-C09  
100-C09  
100-C12  
100-C16  
100-C23  
100-C30  
100-C30  
100-C37  
65  
65  
65  
65  
65  
65  
65  
65  
65  
65  
30  
30  
30  
30  
10  
10  
47  
47  
47  
47  
47  
47  
30  
30  
30  
30  
30  
30  
30  
30  
5
65  
65  
65  
65  
65  
65  
65  
65  
65  
65  
30  
30  
10  
30  
10  
10  
47  
47  
100-C09  
100-C09  
100-C09  
100-C09  
100-C09  
100-C09  
100-C09  
100-C09  
100-C09  
100-C09  
100-C12  
100-C23  
65  
65  
65  
65  
65  
65  
65  
65  
65  
65  
30  
10  
47  
47  
100-C09  
100-C09  
100-C09  
100-C09  
100-C09  
100-C09  
100-C09  
65  
65  
65  
65  
65  
65  
65  
65  
65  
65  
30  
10  
47  
47  
47  
47  
47  
47  
47  
47  
47  
47  
47  
47  
47  
47  
30  
30  
30  
30  
30  
25  
30  
30  
25  
30  
10  
140M-C2E-C25  
30  
140M-C2E-C29  
140M-C2E-C32  
5
5
5
D-Frame  
30  
450  
100-C09  
65  
65  
65  
65  
65  
65  
65  
65  
65  
30  
30  
30  
30  
30  
30  
30  
10  
10  
65  
65  
65  
65  
65  
65  
65  
65  
65  
100-C09  
65  
65  
30  
30  
100-C09  
100-C23  
100-C23  
100-C30  
100-C30  
100-C30  
100-C30  
100-C30  
65  
65  
65  
65  
65  
65  
65  
30  
30  
30  
140M-D8E-B25  
30  
140M-D8E-B40  
140M-D8E-B63  
140M-D8E-C10  
140M-D8E-C16  
140M-D8E-C20  
140M-D8E-C25  
140M-D8E-C29  
140M-D8E-C32  
450  
450  
450  
450  
450  
450  
450  
450  
100-C09  
100-C09  
100-C09  
100-C12  
100-C23  
100-C23  
100-C30  
100-C37  
100-C09  
100-C09  
100-C09  
100-C12  
100-C23  
100-C23  
30  
30  
65  
30  
30  
30  
65  
30  
30  
30  
65  
30  
30  
30  
65  
30  
30  
10  
10  
F-Frame  
30  
140M-F8E-C10  
140M-F8E-C16  
140M-F8E-C20  
140M-F8E-C25  
140M-F8E-C32  
140M-F8E-C45  
600  
600  
600  
600  
600  
600  
100-C30  
100-C30  
100-C30  
100-C30  
100-C30  
100-C37  
65  
65  
65  
65  
65  
65  
30  
30  
30  
30  
30  
18  
65  
65  
65  
65  
65  
65  
100-C30  
100-C30  
100-C30  
100-C30  
100-C30  
100-C37  
65  
65  
65  
65  
65  
65  
30  
30  
30  
30  
30  
100-C30  
100-C30  
100-C30  
100-C30  
100-C30  
100-C37  
65  
65  
65  
65  
65  
65  
30  
30  
30  
30  
30  
30  
30  
30  
30  
18  
(1) For full voltage (delta) ratings above 277V or 347V, follow the NEC or CEC rules for group motor applications.  
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
29  
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
UL Listed Application Ratings - Motor Circuit Protectors with Bulletin 100-C Contactors (Separate Overload Protection Required)  
UL 508 — Manual Motor Controller  
Group Motor Installation  
UL508 Type E Self-Protected Combination  
Motor Controller  
Motor Disconnect  
Minimum  
Contactor  
Size  
Cat. No.  
Max. Fuse or  
C.B. per NEC  
Max. Short Circuit Current [kA] Max. Short Circuit Current [kA] Minimum Max. Short Circuit Current [kA]  
Contactor  
480V  
600V  
480V  
600V  
480Y/277V(1) 600Y/347V(1)  
Size  
C-Frame  
140M-C2N-A16  
140M-C2N-A25  
140M-C2N-A40  
140M-C2N-A63  
140M-C2N-B10  
140M-C2N-B16  
140M-C2N-B25  
450  
450  
450  
450  
450  
450  
450  
100-C09  
100-C09  
100-C09  
100-C09  
100-C09  
100-C09  
100-C09  
65  
65  
65  
65  
65  
65  
65  
47  
47  
47  
47  
47  
47  
30  
65  
65  
65  
65  
65  
65  
65  
47  
47  
47  
47  
47  
47  
30  
100-C09  
100-C09  
100-C09  
100-C09  
100-C09  
100-C09  
100-C09  
65  
65  
65  
65  
65  
65  
65  
47  
47  
47  
47  
47  
47  
D-Frame  
450  
100-C09  
65  
65  
65  
65  
65  
30  
65  
30  
30  
30  
30  
30  
30  
10  
65  
65  
65  
65  
65  
30  
65  
30  
30  
30  
30  
30  
30  
10  
100-C09  
100-C23  
100-C23  
100-C30  
100-C30  
100-C30  
100-C30  
65  
65  
65  
65  
65  
65  
65  
30  
30  
30  
30  
30  
140M-D8N-B25  
140M-D8N-B40  
140M-D8N-B63  
140M-D8N-C10  
140M-D8N-C16  
140M-D8N-C25  
140M-D8N-C32  
450  
450  
450  
450  
450  
450  
100-C09  
100-C09  
100-C09  
100-C12  
100-C23  
100-C37  
F-Frame  
140M-F8N-C25  
140M-F8N-C32  
140M-F8N-C45  
600  
600  
600  
100-C23  
100-C30  
100-C37  
65  
65  
65  
30  
30  
18  
65  
65  
65  
30  
30  
18  
100-C30  
100-C30  
100-C37  
65  
65  
65  
30  
30  
(1) For full-voltage (delta) ratings above 277V or 347V, follow the NEC or CEC rules for group motor applications.  
30  
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
Definition of Type 2 Short Circuit Coordination:  
The contactor or starter must not endanger persons or plant in the event of a short circuit.  
No damage to the motor protection device or other parts may occur with the exception of welding of the contactor or starter contacts if  
these can be easily separated without appreciable deformation (such as with a screwdriver).  
In the event of short circuit, fast-opening, current-limiting Bulletin 140M Motor Protection Circuit Breakers make it possible to build economical,  
fully short-circuit coordinated starter combinations with Type 2 coordination.  
Type 2 Coordination, 400V  
Max. Short-Circuit Current  
Cat. No.  
[kA]  
Minimum Contactor Size  
Standard Motor Protection  
High Inrush Motor Protection Motor Circuit Protection  
C-Frame  
400V  
140M-C2E-A16  
140M-C2E-A25  
140M-C2E-A40  
140M-C2E-A63  
140M-C2E-B10  
140M-C2E-B16  
140M-C2E-B25  
140M-C2E-B40  
140M-C2E-B63  
140M-C2E-C10  
140M-C2E-C16  
140M-C2E-C20  
140M-C2E-C25  
140M-C2E-C29  
140M-C2E-C32  
140M-C2N-A16  
100  
100  
100  
100  
100  
100  
50  
100-C09  
100-C09  
100-C09  
100-C09  
100-C09  
100-C09  
100-C09  
100-C09  
100-C09  
100-C09  
100-C12(1)  
100-C23  
100-C30  
100-C30  
100-C37  
140M-C2T-A16  
140M-C2T-A25  
140M-C2T-A40  
140M-C2T-A63  
140M-C2T-B10  
140M-C2T-B16  
140M-C2T-B25  
140M-C2T-B40  
140M-C2T-B63  
140M-C2T-C10  
140M-C2T-C16  
140M-C2N-A25  
140M-C2N-A40  
140M-C2N-A63  
140M-C2N-B10  
140M-C2N-B16  
140M-C2N-B25  
50  
50  
50  
50  
50  
15  
15  
15  
D-Frame  
140M-D8E-B25  
140M-D8E-B40  
140M-D8E-B63  
140M-D8E-C10  
140M-D8E-C16  
140M-D8E-C20  
140M-D8E-C25  
140M-D8E-C29  
140M-D8E-C32  
140M-D8N-B25  
140M-D8N-B40  
140M-D8N-B63  
140M-D8N-C10  
140M-D8N-C16  
100  
100  
100  
65  
100-C09  
100-C09  
100-C09  
100-C09  
100-C12  
100-C23  
100-C23  
100-C30  
100-C37  
65  
140M-D8T-C16  
140M-D8T-C20  
65  
140M-D8N-C25  
50  
65  
140M-D8N-C32  
65  
F-Frame  
140M-F8E-C10  
140M-F8E-C16  
140M-F8E-C20  
140M-F8E-C25  
140M-F8E-C32  
140M-F8E-C45  
100  
100  
100  
100  
100  
100  
100-C09  
100-C12  
100-C23  
100-C30  
100-C30  
100-C37  
140M-F8N-C25  
140M-F8N-C32  
140M-F8N-C45  
140M-F8T-C25  
140M-F8T-C32  
(1) Cat. No. 100-C16 contactors Type 1 only  
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
31  
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
Type 2 Coordination, 480V  
Cat. No.  
Max. Short-Circuit Current  
[kA]  
Minimum Contactor Size  
Standard Motor Protection  
High Inrush Motor Protection Motor Circuit Protection  
C-Frame  
140M-C2N-A16  
480V  
140M-C2E-A16  
140M-C2E-A25  
140M-C2E-A40  
140M-C2E-A63  
140M-C2E-B10  
140M-C2E-B16  
140M-C2E-B25  
140M-C2E-B40  
140M-C2E-B63  
140M-C2E-C10  
140M-C2E-C16  
140M-C2E-C20  
140M-C2E-C25  
140M-C2E-C29  
140M-C2E-C32  
65  
65  
65  
65  
65  
65  
50  
50  
50  
50  
10  
10  
10  
10  
10  
100-C09  
100-C09  
100-C09  
100-C09  
100-C09  
100-C09  
100-C16  
100-C30  
100-C30  
100-C30  
100-C30  
100-C30  
100-C30  
100-C30  
100-C37  
140M-C2T-A16  
140M-C2T-A25  
140M-C2T-A40  
140M-C2T-A63  
140M-C2T-B10  
140M-C2T-B16  
140M-C2T-B25  
140M-C2T-B40  
140M-C2T-B63  
140M-C2T-C10  
140M-C2T-C16  
140M-C2N-A25  
140M-C2N-A40  
140M-C2N-A63  
140M-C2N-B10  
140M-C2N-B16  
140M-C2N-B25  
D-Frame  
140M-D8E-B25  
140M-D8E-B40  
140M-D8E-B63  
140M-D8E-C10  
140M-D8E-C16  
140M-D8E-C20  
140M-D8E-C25  
140M-D8E-C29  
140M-D8E-C32  
140M-D8N-B25  
140M-D8N-B40  
140M-D8N-B63  
140M-D8N-C10  
140M-D8N-C16  
65  
65  
65  
65  
65  
65  
65  
65  
65  
100-C09  
100-C09  
100-C09  
100-C09  
100-C12  
100-C23  
100-C23  
100-C30  
100-C37  
140M-D8T-C16  
140M-D8T-C20  
140M-D8N-C25  
140M-D8N-C32  
F-Frame  
140M-F8E-C10  
140M-F8E-C16  
140M-F8E-C20  
140M-F8E-C25  
140M-F8E-C32  
140M-F8E-C45  
65  
65  
65  
65  
65  
65  
100-C09  
100-C12  
100-C23  
100-C30  
100-C30  
100-C37  
140M-F8N-C25  
140M-F8N-C32  
140M-F8N-C45  
140M-F8T-C25  
140M-F8T-C32  
32  
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
Type 2 Coordination, 600V  
Standard Motor Protection  
Max. Short-Circuit Current  
Cat. No.  
[kA]  
Minimum Contactor Size  
High Inrush Motor  
Protection  
Motor Circuit Protection  
600V  
C-Frame  
140M-C2N-A16  
140M-C2N-A25  
140M-C2N-A40  
140M-C2N-A63  
140M-C2N-B10  
140M-C2N-B16  
140M-C2N-B25  
140M-C2E-A16  
140M-C2E-A25  
140M-C2E-A40  
140M-C2E-A63  
140M-C2E-B10  
140M-C2E-B16  
140M-C2E-B25  
140M-C2E-B40  
140M-C2E-B63  
140M-C2E-C10  
140M-C2E-C16  
140M-C2E-C20  
140M-C2E-C25  
140M-C2E-C29  
140M-C2E-C32  
47  
47  
47  
47  
47  
47  
10  
10  
5
100-C09  
100-C09  
100-C09  
100-C09  
100-C09  
100-C09  
100-C16  
100-C16  
100-C23  
100-C30  
100-C30  
100-C30  
100-C30  
100-C30  
100-C37  
140M-C2T-A16  
140M-C2T-A25  
140M-C2T-A40  
140M-C2T-A63  
140M-C2T-B10  
140M-C2T-B16  
140M-C2T-B25  
140M-C2T-B40  
140M-C2T-B63  
140M-C2T-C10  
140M-C2T-C16  
5
5
5
5
5
5
D-Frame  
140M-D8N-B25  
140M-D8N-B40  
140M-D8N-B63  
140M-D8N-C10  
140M-D8N-C16  
140M-D8E-B25  
140M-D8E-B40  
140M-D8E-B63  
140M-D8E-C10  
140M-D8E-C16  
140M-D8E-C20  
140M-D8E-C25  
140M-D8E-C29  
140M-D8E-C32  
30  
30  
30  
30  
30  
5
100-C30  
100-C30  
100-C30  
100-C30  
100-C30  
100-C30  
100-C30  
100-C30  
100-C37  
140M-D8T-C16  
140M-D8T-C20  
140M-D8N-C25  
5
10  
10  
140M-D8N-C32  
F-Frame  
140M-F8E-C10  
140M-F8E-C16  
140M-F8E-C20  
140M-F8E-C25  
140M-F8E-C32  
140M-F8E-C45  
30  
30  
30  
30  
30  
10  
100-C30  
100-C30  
100-C30  
100-C30  
100-C30  
100-C37  
140M-F8N-C25  
140M-F8N-C32  
140M-F8N-C45  
140M-F8T-C25  
140M-F8T-C32  
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
33  
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
IEC Performance Data  
Cat.No.140M-C2E-  
A16 A25 A40 A63 B10 B16 B25 B40 B63 C10 C16 C20 C25 C29 C32  
Rated Operational Current, Ie  
Magnetic Release Current  
[A]  
[A]  
0.16 0.25  
2.1 3.3  
0.4  
5.2  
0.63  
8.2  
1
1.6  
21  
2.5  
33  
4
6.3  
82  
10  
16  
20  
25  
29  
32  
13  
52  
130  
208  
260  
325  
406  
448  
Switching of Standard Three-Phase Motors, AC-3  
230/240V  
400/415V  
500V  
[kW]  
[kW]  
[kW]  
[kW]  
0.06 0.09 0.18 0.25 0.37 0.75  
1.5  
2.2  
3.0  
4.0  
2.2  
4.0  
6.3  
7.5  
4.0  
7.5  
10  
5.5  
10  
11  
17  
5.5  
11  
15  
22  
7.5  
13  
7.5  
15  
20  
25  
0.02 0.04 0.09 0.18 0.25 0.55 0.75  
1.5  
2.2  
3.0  
0.06 0.09 0.12 0.18 0.37 0.75  
1.1  
1.8  
18.5  
25  
690V  
0.06 0.09 0.18 0.25 0.55  
1.1  
13  
Back-Up Fuses gG, gL, only if Icc Icu  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
230/240V  
400/415V  
440/460V  
500V  
[A]  
[A]  
[A]  
[A]  
[A]  
100  
100  
80  
100  
100  
80  
125  
125  
100  
100  
80  
125  
125  
100  
100  
80  
80  
80  
80  
63  
63  
80  
50  
80  
80  
690V  
16  
20  
35  
50  
63  
63  
Ultimate Short Circuit Breaking Capacity, Icu  
230/240V  
400/415V  
440/460V  
500V  
[kA]  
[kA]  
[kA]  
[kA]  
[kA]  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
8
100  
100  
100  
100  
6
100  
100  
100  
100  
6
100  
100  
100  
100  
4
100  
100  
50  
100  
65  
10  
10  
3
65  
50  
6
65  
15  
6
50  
15  
6
50  
15  
6
50  
6
6
6
6
690V  
4
3
3
3
3
Rated Service Short Circuit Breaking Capacity, Ics  
230/240V  
400/415V  
440/460V  
500V  
[kA]  
[kA]  
[kA]  
[kA]  
[kA]  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
8
100  
100  
100  
100  
6
100  
100  
100  
100  
6
100  
100  
100  
100  
4
100  
100  
50  
100  
50  
6
50  
15  
6
50  
15  
6
25  
15  
6
25  
15  
6
50  
6
6
6
6
6
690V  
4
3
3
3
3
3
(1) No back-up fuse required.  
34  
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
Cat.No.140M-D8E-  
Cat.No.140M-F8E-  
B25 B40 B63 C10 C16 C20 C25 C29 C32 C10 C16 C20 C25 C32 C45  
Rated Operational Current, Ie  
Magnetic Release Current  
[A]  
[A]  
2.5  
33  
4.0  
52  
6.3  
82  
10  
16  
20  
25  
29  
32  
10  
16  
20  
25  
32  
45  
130  
208  
260  
325  
406  
448  
130  
208  
260  
325  
416  
585  
Switching of Standard Three-Phase Motors, AC-3  
230/240V  
[kW]  
[kW]  
[kW]  
[kW]  
Icu  
0.37 0.75  
1.5  
2.2  
3.0  
4.0  
2.2  
4.0  
6.3  
7.5  
4.0  
7.5  
10  
5.5  
10  
11  
17  
5.5  
11  
15  
22  
7.5  
13  
7.5  
15  
20  
25  
2.2  
4.0  
6.3  
7.5  
4.0  
7.5  
10  
5.5  
10  
11  
17  
6.3  
11  
15  
22  
7.5  
15  
20  
30  
13  
22  
30  
40  
400/415V  
0.75  
1.1  
1.5  
2.2  
3.0  
500V  
18.5  
25  
690V  
1.8  
13  
13  
Back-Up Fuses gG, gL, only if Icc  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
230/240V  
400/415V  
440/460V  
500V  
[A]  
[A]  
100  
100  
80  
100  
100  
80  
125  
125  
100  
80  
125  
125  
100  
80  
80  
80  
80  
63  
100  
100  
100  
80  
100  
100  
100  
80  
100  
100  
100  
80  
125  
125  
125  
100  
125  
125  
125  
100  
[A]  
80  
80  
63  
[A]  
690V  
[A]  
20  
35  
50  
50  
63  
63  
Ultimate Short Circuit Breaking Capacity, Icu  
230/240V  
400/415V  
440/460V  
500V  
[kA]  
[kA]  
[kA]  
[kA]  
[kA]  
100  
100  
100  
100  
10  
100  
100  
100  
100  
10  
100  
100  
100  
100  
6
100  
100  
50  
100  
100  
50  
100  
100  
50  
50  
6
100  
65  
50  
50  
6
65  
50  
25  
25  
6
65  
50  
25  
25  
6
100  
100  
65  
100  
100  
65  
100  
100  
65  
100  
100  
65  
100  
65  
100  
65  
65  
50  
50  
50  
50  
50  
50  
50  
50  
50  
690V  
6
6
10  
10  
10  
10  
10  
10  
Rated Service Short Circuit Breaking Capacity, Ics  
230/240V  
400/415V  
440/460V  
500V  
[kA]  
[kA]  
[kA]  
[kA]  
[kA]  
100  
100  
100  
100  
10  
100  
100  
100  
100  
10  
100  
100  
100  
100  
6
100  
100  
50  
100  
50  
50  
50  
4
100  
25  
25  
25  
4
100  
25  
25  
25  
4
50  
25  
20  
20  
4
50  
25  
20  
20  
4
100  
50  
50  
50  
10  
100  
50  
100  
50  
50  
50  
10  
100  
50  
100  
50  
50  
50  
6
100  
50  
50  
50  
6
50  
50  
50  
50  
50  
690V  
6
10  
10  
(1) No back-up fuse required.  
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
35  
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
Cat. No. 140M-D8V-  
B16  
1.6  
82  
B25  
2.5  
82  
B40  
4
B63  
6.3  
82  
C10  
10  
C16  
16  
C20  
20  
C25  
25  
C29  
29  
C32  
32  
Rated Operational Current, Ie  
Magnetic Release Current  
[A]  
[A]  
82  
130  
208  
260  
325  
406  
448  
Switching of Standard Three-Phase Motors, AC-3  
230/240V  
[kW]  
[kW]  
[kW]  
0.25  
0.55  
0.75  
0.37  
0.75  
1.1  
0.75  
1.5  
1.5  
2.2  
3
2.2  
4
4
5.5  
10  
11  
5.5  
11  
15  
7.5  
13  
7.5  
15  
20  
400/415V  
7.5  
10  
500V  
2.2  
6.3  
18.5  
Back-Up Fuses gG, gL, only if Icc Icu  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
230/240V  
400/415V  
440/460V  
500V  
[A]  
[A]  
[A]  
[A]  
100  
100  
80  
100  
100  
80  
125  
125  
100  
125  
125  
100  
80  
80  
Ultimate Short Circuit Breaking Capacity, Icu  
230/240V  
400/415V  
440/460V  
500V  
[kA]  
[kA]  
[kA]  
[kA]  
65  
65  
65  
65  
65  
65  
65  
65  
65  
65  
65  
65  
65  
65  
65  
65  
65  
65  
50  
50  
65  
65  
50  
50  
65  
65  
50  
50  
65  
65  
50  
50  
65  
50  
25  
25  
65  
50  
25  
25  
Rated Service Short Circuit Breaking Capacity, Ics  
230/240V  
400/415V  
440/460V  
500V  
[kA]  
[kA]  
[kA]  
[kA]  
65  
65  
65  
65  
65  
65  
65  
65  
65  
65  
65  
65  
65  
65  
65  
65  
65  
65  
50  
50  
65  
50  
50  
50  
65  
25  
25  
25  
65  
25  
25  
25  
50  
25  
20  
20  
50  
25  
20  
20  
(1) No back-up fuse required.  
36  
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
Cat.No.140M-C2N-  
A16  
0.16  
2.1  
A25  
0.25  
3.3  
A40  
0.4  
A63  
0.63  
8.2  
B10  
1
B16  
1.6  
21  
B25  
2.5  
32  
Rated Operational Current, Ie  
Magnetic Release Current  
[A]  
[A]  
5.2  
13  
Switching of Standard Three-Phase Motors, AC-3  
230/240V  
[kW]  
[kW]  
[kW]  
[kW]  
0.06  
0.09  
0.12  
0.18  
0.09  
0.18  
0.18  
0.25  
0.18  
0.25  
0.37  
0.55  
0.25  
0.55  
0.75  
1.1  
0.37  
0.75  
1.1  
400/415V  
0.02  
0.06  
0.06  
0.04  
0.09  
0.09  
500V  
690V  
1.8  
Back-Up Fuses gG, gL, only if Icc Icu  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
230/240V  
400/415V  
440/460V  
500V  
[A]  
[A]  
[A]  
[A]  
[A]  
690V  
16  
20  
Ultimate Short Circuit Breaking Capacity, Icu  
230/240V  
400/415V  
440/460V  
500V  
[kA]  
[kA]  
[kA]  
[kA]  
[kA]  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
10  
100  
100  
100  
100  
6
690V  
Rated Service Short Circuit Breaking Capacity, Ics  
230/240V  
400/415V  
440/460V  
500V  
[kA]  
[kA]  
[kA]  
[kA]  
[kA]  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
8
100  
100  
100  
100  
6
690V  
(1) No back-up fuse required.  
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
37  
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
Cat.No.140M-D8N-  
Cat.No.140M-F8N-  
B25  
2.5  
32  
B63  
4.0  
52  
B40  
6.3  
82  
C10  
10  
C16  
16  
C25  
25  
C32  
32  
C25  
25  
C32  
32  
C45  
45  
Rated Operational Current, Ie  
Magnetic Release Current  
[A]  
[A]  
130  
208  
325  
448  
325  
416  
585  
Switching of Standard Three-Phase Motors, AC-3  
230/240V  
[kW]  
[kW]  
[kW]  
[kW]  
Icu  
0.37  
0.75  
1.1  
0.75  
1.5  
2.2  
3.0  
1.5  
2.2  
3.0  
4.0  
2.2  
4.0  
6.3  
7.5  
4.0  
7.5  
10  
5.5  
11  
15  
22  
7.5  
15  
20  
25  
6.3  
11  
15  
22  
7.5  
15  
20  
30  
13  
22  
30  
40  
400/415V  
500V  
690V  
1.8  
13  
Back-Up Fuses gG, gL, only if Icc  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
230/240V  
400/415V  
440/460V  
500V  
[A]  
100  
100  
100  
100  
80  
125  
125  
125  
125  
100  
125  
125  
125  
125  
100  
[A]  
100  
100  
80  
125  
125  
100  
80  
[A]  
80  
80  
63  
[A]  
690V  
[A]  
20  
35  
50  
50  
63  
Ultimate Short Circuit Breaking Capacity, Icu  
230/240V  
400/415V  
440/460V  
500V  
[kA]  
[kA]  
[kA]  
[kA]  
[kA]  
100  
100  
100  
100  
10  
100  
100  
100  
100  
6
100  
100  
100  
100  
10  
100  
100  
50  
100  
100  
50  
100  
65  
50  
25  
6
65  
50  
25  
25  
6
100  
100  
65  
100  
65  
65  
50  
10  
100  
65  
50  
50  
50  
50  
50  
690V  
6
6
10  
10  
Rated Service Short Circuit Breaking Capacity, Ics  
230/240V  
400/415V  
440/460V  
500V  
[kA]  
[kA]  
[kA]  
[kA]  
[kA]  
100  
100  
100  
100  
10  
100  
100  
100  
100  
6
100  
100  
100  
100  
10  
100  
100  
50  
100  
50  
50  
50  
4
100  
25  
25  
25  
4
50  
25  
20  
20  
4
100  
50  
100  
50  
50  
50  
6
100  
50  
50  
50  
6
50  
50  
50  
690V  
6
10  
(1) No back-up fuse required.  
38  
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
Cat.No.140M-C2T-  
B10 B16 B25  
A16  
0.16  
3.2  
A25  
0.25  
5.2  
A40  
0.40  
8.2  
A63  
0.63  
13  
B40  
4.0  
82  
B63  
6.3  
C10  
10  
C16  
16  
Rated Operational Current, Ie  
Magnetic Release Current  
[A]  
[A]  
1.0  
21  
1.6  
32  
2.5  
52  
130  
208  
260  
Switching of Standard Three-Phase Motors, AC-3  
230/240V  
[kW]  
[kW]  
[kW]  
[kW]  
0.06  
0.09  
0.12  
0.18  
0.09  
0.18  
0.18  
0.25  
0.18  
0.25  
0.37  
0.55  
0.25  
0.55  
0.75  
1.1  
0.37  
0.75  
1.1  
0.75  
1.5  
2.2  
3.0  
1.5  
2.2  
3.0  
4.0  
2.2  
4.0  
6.3  
7.5  
4.0  
7.5  
10  
400/415V  
0.02  
0.06  
0.06  
0.04  
0.09  
0.09  
500V  
690V  
1.8  
13  
Back-Up Fuses gG, gL, only if Icc  
Icu  
[A]  
[A]  
[A]  
[A]  
[A]  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
230/240V  
400/415V  
440/460V  
500V  
80  
80  
80  
63  
63  
80  
50  
690V  
16  
20  
35  
50  
Ultimate Short Circuit Breaking Capacity, Icu  
230/240V  
400/415V  
440/460V  
500V  
[kA]  
[kA]  
[kA]  
[kA]  
[kA]  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
8
100  
100  
100  
100  
6
100  
100  
100  
100  
6
100  
100  
100  
100  
4
100  
100  
10  
100  
50  
10  
10  
3
10  
690V  
4
Rated Service Short Circuit Breaking Capacity, Ics  
230/240V  
400/415V  
440/460V  
500V  
[kA]  
[kA]  
[kA]  
[kA]  
[kA]  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
8
100  
100  
100  
100  
6
100  
100  
100  
100  
6
100  
100  
100  
100  
4
100  
100  
10  
100  
15  
6
10  
6
690V  
4
3
(1) No back-up fuse required.  
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
39  
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
Cat.No.140M-D8T-  
Cat.No.140M-F8T-  
C16  
16  
C20  
20  
C25  
25  
C32  
32  
Rated Operational Current, Ie  
Magnetic Release Current  
[A]  
[A]  
260  
325  
416  
585  
Switching of Standard Three-Phase Motors, AC-3  
230/240V(1)  
[kW]  
[kW]  
[kW]  
[kW]  
4.0  
7.5  
10  
5.5  
10  
11  
17  
6.3  
11  
15  
22  
7.5  
15  
20  
30  
(1)  
400/415V  
(1)  
500V  
(1)  
690V  
13  
Back-Up Fuses gG, gL, only if Icc Icu  
(2)  
(2)  
(2)  
(2)  
230/240V  
400/415V  
440/460V  
500V  
[A]  
[A]  
[A]  
[A]  
[A]  
80  
80  
80  
63  
100  
100  
80  
100  
100  
100  
80  
125  
125  
125  
100  
690V  
63  
Ultimate Short Circuit Breaking Capacity, Icu  
230/240V  
400/415V  
440/460V  
500V  
[kA]  
[kA]  
[kA]  
[kA]  
[kA]  
100  
100  
50  
100  
65  
25  
25  
6
100  
65  
100  
65  
65  
65  
50  
50  
50  
690V  
6
10  
10  
Rated Service Short Circuit Breaking Capacity, Ics  
230/240V  
400/415V  
440/460V  
500V  
[kA]  
[kA]  
[kA]  
[kA]  
[kA]  
100  
25  
25  
25  
4
100  
25  
25  
25  
4
100  
50  
50  
50  
6
100  
50  
50  
50  
6
690V  
(1) Consult your local Rockwell Automation sales office or Allen-Bradley distributor.  
(2) No back-up fuse required.  
General Data  
Cat.No.  
140M-C  
140M-D  
140M-F  
Rated Insulation Voltage Ui  
IEC, SEV, VDE0660  
[V]  
[V]  
690  
600  
UL, CSA  
Rated Impulse Withstand Voltage Uimp  
Pollution degree  
3
Main circuits Uimp/Overvoltage Category  
Auxiliary circuits Uimp/Overvoltage Category  
6
6
kV/III  
kV/III  
Rated Frequency  
[Hz]  
50/60  
Utilization Category  
IEC60947-2 (Circuit breaker)  
IEC60947-4-1 (Motor starter)  
Lifespan  
A
AC-3  
Mechanical  
[operations]  
[operations]  
[operations/h]  
100000  
100000  
30000  
30000  
Electrical (Ie max.)  
Switching Frequency  
Ambient Temperature  
Storage  
max.25  
[°C]  
[°C]  
-40…+80  
-25…+60  
Operation  
40  
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
Cat.No.  
140M-C  
140M-D  
140M-F  
Climatic resistance  
Moisture change climate (600068-2-30)  
Dry heat (60086-2-2)  
Moisture heat (60068-2-3)  
Site Altitude  
23°C/83% relative humidity and 40°C/92% relative humidity, 56 cycles  
100°C, relative humidity <50%, 7 days  
40°C, relative humidity 93%, 56 days  
to 2000 N.N.  
[m]  
140M-C; 140M-D : IP2X from all directions  
140M-F : IP2X from front with front (upper) terminal wired  
Protection Class  
Resistance to Shock, Transport (60068-2-27)  
Resistance to Vibration, Operation (60068-2-6)  
Rated Thermal Current Ith  
30 g,11 ms, all axes  
5
g
up to 40°C ambient temperature  
[A]  
[A]  
[A]  
0.1…32  
0.1…32  
0.1…32  
1.6…32 (1.0…32 for -D8V)  
1.6…32 (1.0…32 for -D8V)  
1.6…32 (1.0…32 for -D8V)  
6.3…45  
6.3…45  
6.3…45  
up to 60°C ambient temperature  
Rated Supply Current Ie  
Dependence on Temperature  
40°C  
50°C  
[A]  
[A]  
[A]  
[A]  
no reduction  
no reduction  
60°C  
no reduction  
70°C  
15% current reduction of the upper rated current Ie  
Overload Protection  
Characteristics  
IEC 60947-4-1Motor protection (except Cat.Nos.140M-C2N,140M-D8N,140M-F8N)  
-20…+60  
Ambient Temperature  
Compensation  
[°C]  
Phase-loss Protection  
Trip class  
Differential release  
10 (except Cat.Nos.140M-C2N,140M-D8N,140M-F8N) fixed setting  
fixed setting  
13…14 x Ie max. (for 140M-C2E,140M-D8E,140M-F8E,140M-C2N,140M-D8N,140M-F8N)  
16…21 x Ie max. (for 140M-C2T, 140M-D8T, 140M-F8T)  
Ie max. = maximum values of setting ranges  
Magnetic Release current (20%)  
fixed magnetic setting for 140M-D8V; see ratings  
Total Power Loss Pv  
Circuit Breaker at rated load  
operating temperature  
[W]  
6…11.5  
6…11.6  
9…16  
Main Disconnect Switch Application  
Yes, with accessories  
For utilization outside North America, assemblies (of products) shall comply to the IEC61439-1 requirements  
Application Conditions  
140M manual motor starters are intended for use in closed areas without hazardous operating conditions such as dust or  
explosive or corrosive gases. Enclosures of appropriate manner need to be in place to protect devices in such environments.  
PWM frequency ≤ 4 kHz  
VFD output frequency 0…400 Hz  
Maximum cable length that is listed i n the drive instruction manual applies. Adding a common mode core and utilizing XLPE  
Application Conditions (140M-D8V)  
cable helps minimize cable charging current.  
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
41  
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
Cat.No.  
Conformity to Standards  
140M-C…  
140M-D…  
IEC60947-1;-2;-4-1; EN60947-1;-2;-4-1;  
UL508; CSA22.2, No.14  
140M-F…  
Approvals  
CE,UL,CSA  
Terminal Parts  
Type of terminals  
Screwdriver  
PozidrivNo.2/BladeNo.  
3
PozidrivNo.2/BladeNo.3  
1.conductor  
2.conductor  
[mm2]/[AWG]  
[mm2]/[AWG]  
1…6/No.16…10  
1…4/No.16…10  
2.5…25/No.14…4  
2.5…25/No.14…4  
1.conductor  
2.conductor  
[mm2]/[AWG]  
1…6/No.16…10  
1…6/No.16…10  
2.5…25/No.14…4  
2.5…25/No.14…4  
[mm2]/[AWG]  
1.conductor  
2.conductor  
[mm2]/[AWG]  
[mm2]/[AWG]  
1.5…6/No.16…8  
1.5…6/No.16…8  
16…25/No.14…4  
16…25/No.14…4  
1.conductor  
2.conductor  
[mm2]/[AWG]  
1…6/No.16…10  
1…6/No.16…10  
2.5…10/No.14…8  
2.5…10/No.14…8  
[mm2]/[AWG]  
Tightening torque  
[N•m]/[lb•in]  
2…2.5/18…22  
3…3.5/27…30  
Cat.No.  
140M-RC…  
Terminal Parts  
Type of terminals  
2…3.5  
Screwdriver  
0.2…0.6  
0.5…2.5/—  
0.5…2.5/—  
1.conductor [mm2]/[AWG]  
2.conductor [mm2]/[AWG]  
1.conductor [mm2]/[AWG]  
0.5…2.5/No.18…12  
0.5…2.5/No.18…12  
2.conductor [mm2]/[AWG]  
1.conductor [mm2]/[AWG]  
2.conductor [mm2]/[AWG]  
1…4/No.16…12  
1…4/No.16…12  
Accessories for Bulletin 140M Motor Protection Circuit Breakers  
Auxiliary Contact Blocks for Front Mounting  
Cat.No.140M-C-AFA…,140M-C-AFAR…  
Auxiliary Contact Blocks for Right-Side Mounting  
Cat.No.140M-C-ASA…,140M-C-ASAR…  
Rated Thermal Current Ith  
at 40°C ambient temperature   
at 60°C ambient temperature  
[A]  
[A]  
5
4
10  
6
Contact Class Coordination According to NEMA  
AC  
B
300  
B
600  
(UL/CSA Standards)  
DC  
Q
300  
10  
Q
600  
10  
Back-Up Fuses gG, gL  
Rated Supply Current  
[A]  
[V]  
[A]  
[V]  
[A]  
24  
4
120  
3
240  
1.5  
24  
6
120  
5
240  
3
415  
2
690  
0.7  
AC-15  
DC-13  
24  
2
120  
0.5  
240  
0.25  
24  
2
120  
0.5  
240  
0.25  
415  
0.15  
Terminal Parts  
Type of terminals  
Screwdriver  
PozidrivNo.2/BladeNo.3  
1.conductor [mm2]/[AWG]  
2.conductor [mm2]/[AWG]  
0.5…1.5/18…14  
0.75…1.5/18…14  
0.5…2.5/18…14  
0.75…2.5/18…14  
42  
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
Auxiliary Contact Blocks for Front Mounting  
Cat.No.140M-C-AFA…,140M-C-AFAR…  
Auxiliary Contact Blocks for Right-Side Mounting  
Cat.No.140M-C-ASA…,140M-C-ASAR…  
1.conductor [mm2]/[AWG]  
2.conductor [mm2]/[AWG]  
0.75…1.5/18…14  
0.75…1.5/18…14  
0.75…2.5/18…14  
0.75…2.5/18…14  
1.conductor [mm2]/[AWG]  
0.75…1.5/18…14  
0.75…1.5/18…14  
0.75…2.5/18…14  
0.75…2.5/18…14  
2.conductor [mm2]/[AWG]  
Tightening torque  
[N•m]/[lb•in]  
1.2…1.5/10.6…13  
1.2…1.5/10.6…13  
Undervoltage Trip for Left-Side  
Mounting  
Undervoltage Trip with 2 Auxiliary  
Contacts for Left-Side Mounting  
Shunt Trip for Left-Side  
Mounting Cat.No.140M-C-SN…  
Cat.No.140M-C-UX…  
Cat.No.140M-C-UC…  
Actuating Voltage  
Pull-in  
Drop-out  
0.85…1.1 x Us  
0.7…0.35 x Us  
0.85…1.1 x Us  
0.7…0.35 x Us  
0.7…1.1 x Us  
min.  
max.  
21V 50 Hz,24V 60 Hz  
600V 50 Hz  
21V 50 Hz,24V 60 Hz  
600V 50 Hz  
21V 50 Hz, 24V 60 Hz  
600V 50 Hz  
Rated Control Voltage  
On-Time  
100%  
100%  
AC: 100%; DC: max. 5 sec.  
Pull-in  
Hold  
8.5VA, 8  
4VA, 2  
W
W
8.5VA, 8  
4VA, 2  
W
W
8.5VA, 8 W  
4VA, 2 W  
Coil Rating  
Terminal Parts  
Type of terminals  
Screwdriver  
PozidrivNo.2/BladeNo.3  
1.conductor [mm2]/[AWG]  
2.conductor [mm2]/[AWG]  
0.5…2.5/No.18…14  
0.75…2.5/No.18…14  
1.conductor [mm2]/[AWG]  
0.75…2.5/No.18…14  
0.75…2.5/No.18…14  
2.conductor [mm2]/[AWG]  
1.conductor [mm2]/[AWG]  
2.conductor [mm2]/[AWG]  
0.75…2.5/No.18…14  
0.75…2.5/No.18…14  
Tightening torque  
[N•m]/[lb•in]  
1.2…1.5/10.6…13.3  
Compact Busbar Feeder  
Terminal  
140M-C-WTN  
140M-F-WTE  
140M-C-WTEN  
Compact Busbar  
140M-C 140M-F  
Compact Busbar Feeder Block  
140M-C-  
140M-C-  
140M-F-  
140M-F-  
-W…  
-W… WBEL1,L2,L3 WBET1,T2,T3 WBEL1,L2,L3 WBET1,T2,T3  
Rated Thermal Current Ith  
at 60°C ambient temperature  
[A]  
64  
120  
64  
120  
64  
IEC120/UL115  
for use with  
140M-C-W  
for use with  
140M-F-W  
1.conductor [mm2]/[AWG] 2.5…25/14…4  
4…25/10…4  
4…50/10…4  
4…25/10…4  
for use with  
140M-C-W  
for use with  
140M-F-W  
1.conductor [mm2]/[AWG] 2.5…25/14…4 4…50/12…1/0  
4…25/10…4  
for use with  
140M-C-W  
for use with  
140M-F-W  
2.5…50/  
1.conductor [mm2]/[AWG] 2.5…25/14…4  
12…1/0  
2.5…25/  
14…4  
2.5…25/  
14…4  
3…3.5/  
27…31  
2.5…3/  
23…27  
Tightening torque  
[N•m]/[lb•in] 3…3.5/27…31 5…6/45…54  
5…6/45…54  
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
43  
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
Accessories for Bulletin 140M Screwless  
Cat.No.  
140M-RC…  
Terminal Parts  
Type of terminals  
2…3.5  
Screwdriver  
0.2…0.6  
1.conductor [mm2]/[AWG]  
2.conductor [mm2]/[AWG]  
0.5…1.5/—  
0.5…1.5/—  
1.conductor [mm2]/[AWG]  
0.5…1.5/No.18…14  
0.5…1.5/No.18…14  
2.conductor [mm2]/[AWG]  
1.conductor [mm2]/[AWG]  
2.conductor [mm2]/[AWG]  
0.5…1.5/No.18…14  
0.5…1.5/No.18…14  
Weights  
Description  
Weight [g]  
317  
Cat.No.  
140MC-C2E-…  
140M-D8E-…  
140MC-F8E-…  
140M-C2N-…  
140M-D8N-…  
140M-F8N-…  
140M-C2T-…  
140M-D8T-…  
140M-F8T-…  
Description  
Anti-Tamper Cover  
Weight [g]  
Cat.No.  
140M-C-CA  
2
373  
140M-C-KN1  
Lockable Twist Knob  
Locking Tag  
5
782  
140M-C-KRY1  
140M-C-M3  
315  
30  
Motor Protection Circuit Breakers  
365  
140M-C-DN66  
140M-C-NRY66  
140M-C-DS  
Door Coupling Handle  
123  
782  
315  
Extension Shaft  
Legend Plate  
46  
4
365  
140M-C-DFC…  
140M-C-WTEN  
140M-F-WT  
782  
51  
172  
27  
48  
69  
90  
30  
55  
80  
105  
6
Feeder Terminal  
140M-C-AFA10  
140M-C-AFA01  
140M-C-AFA11  
140M-C-AFA20  
140M-C-ASA…  
140M-C-AFAR10A…  
140M-C-ASAR…M…  
140M-C-ASAM11  
140M-C-UX…  
140M-C-SN…  
140M-C-UC…  
140M-C-W452N  
140M-C-W453N  
140M-C-W454N  
140M-C-W455N  
140M-C-W542N  
140M-C-W543N  
140M-C-W544N  
140M-C-W545N  
140-KBH2  
10  
Auxiliary Contacts  
Compact Busbars  
15  
108  
110  
116  
Undervoltage Trip  
Top Hat Rail Adapter  
Cutoff Current  
The Bulletin 140-M limits solid short-circuit current Icc(prospective short-circuit current). IDis the maximum cutoff current (highest  
instantaneous value of the limited short-circuit current). This value is indicated in the following diagrams as a function of the progressive system  
short-circuit current.  
I
I
asymmetrical  
symmetrical  
cc  
cc  
44  
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
Bulletin140M-C Circuit Breaker (Maximum Cutoff Current)  
140M-C2E, -C2N, -C2T  
Max. Cut-Off Current, U = 400…415V  
e
100  
10  
1
0.25  
0.3  
0.5  
20 A  
16 A  
0.7  
29 / 32 A  
25 A  
0.8  
10 A  
6.3 A  
0.9  
4.0 A  
2.5 A  
0.95  
cos φ  
1.0 A  
0.1  
0.1  
1
10  
100  
Prospective current [kA r.m.s]  
Bulletin140M-D8E, -D8N, D8T Circuit Breaker (Maximum Cutoff Current)  
140M-D8E, -D8N, -D8T  
Max. Cut-Off Current, U = 400…415V  
e
100  
10  
1
0.25  
0.3  
0.5  
29 / 32 A  
25 A  
0.7  
16 / 20 A  
0.8  
10 A  
6.3 A  
0.9  
4.0 A  
2.5 A  
0.95  
cos φ  
0.1  
0.1  
1
10  
100  
Prospective current [kA r.m.s]  
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
45  
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
Bulletin140M-D8V Circuit Breaker (Maximum Cutoff Current)  
140M-D8V  
Max. Cut-Off Current, Ue = 400…415V  
100  
10  
1
0.25  
0.3  
0.5  
29 / 32 A  
25 A  
16 / 20 A  
0.7  
0.8  
10 A  
6.3 A  
4.0 A  
0.9  
cos  
0.95  
2.5 A  
1.6 A  
0.1  
0.1  
1
10  
100  
Prospective current [kA r.m.s]  
Bulletin140M-F Circuit Breaker (Maximum Cutoff Current)  
140M-F8E, -F8N, -F8T  
Max. Cut-Off Current, U = 400…415V  
e
100  
10  
1
0.2  
0.3  
45 A  
0.5  
32/25 A  
20 A  
16 A  
0.7  
10 A  
0.8  
0.9  
0.95  
cos φ  
0.1  
0.1  
1
10  
100  
Prospective current [kA r.m.s]  
46  
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
Bulletin140M-C Circuit Breaker (Maximum Let-through Energy  
)
140M-C2E, -C2N, -C2T  
Max. Let-Through-Energy, Ue = 400…415V  
1.00E+06  
1.00E+05  
1.00E+04  
1.00E+03  
1.00E+02  
1 Half-Cycle (50Hz)  
25 A  
29 / 32 A  
20 A  
16 A  
10 A  
6.3 A  
4.0 A  
2.5 A  
1.6 A  
0.1  
1
10  
100  
Prospective current [kA r.m.s]  
Bulletin140M-D8E, -D8N, -D8T Circuit Breaker (Maximum Let-through Energy  
)
140M-D8E, -D8N, -D8T  
Max. Let-Through-Energy, Ue = 400…415V  
1.00E+06  
1.00E+05  
1.00E+04  
1.00E+03  
1.00E+02  
1 Half-Cycle (50Hz)  
32 A  
29 A  
25 A  
20 / 16 A  
10 A  
6.3 A  
4.0 A  
2.5 A  
0.1  
1
10  
100  
Prospective current [kA r.m.s]  
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
47  
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
Bulletin140M-D8V Circuit Breaker (Maximum Let-through Energy  
)
140M-D8V  
Max. Let-Through-Energy, Ue = 400... 415V  
1.E+06  
1.E+05  
1.E+04  
1.E+03  
1.E+02  
1 Half-Cycle (50 Hz)  
32 A  
29 A  
25 A  
20 / 16 A  
10 A  
6.3 A  
4.0 A  
2.5 A  
1.6 A  
0.1  
1
10  
100  
Prospective current [kA r.m.s]  
Bulletin140M-F Circuit Breaker (Maximum Let-through Energy  
)
140M-F8E, -F8N, -F8T  
Max. Let-Through-Energy, Ue = 400…415V  
1.00E+06  
1.00E+05  
1.00E+04  
1.00E+03  
1.00E+02  
45 A  
1 Half-Cycle (50Hz)  
32 A  
25 A  
20 A  
16 A  
10 A  
0.1  
1
10  
100  
Prospective current [kA r.m.s]  
48  
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
Time-Current Characteristic  
Motor Protection Circuit Breakers Time-Current Characteristic  
10 000  
1h  
1 000  
100  
10  
1
1
2
0.1  
0.01  
0.001  
0.8  
1
2
4
6
10  
20  
40 60 100  
Multiple of the set current I  
eF  
140M-C, -D, -F Motor Protection Circuit Breakers (for 140M-D8V, see ratings)  
Thermal Release Trip Current  
The adjustable current-dependent delayed bimetal release protects motors against overload. The curve shows the mean operating current at an  
ambient temperature of 20 °C starting from the cold state. Careful testing and setting ensures effective motor protection even in the case of single  
phasing. The overload characteristic is also valid for transformer protection.  
Magnetic Release Trip Current  
The instantaneous magnetic trip has a fixed operating current setting. This corresponds to 13…14 times the maximum value of setting range.  
(Transformer protection up to 20 x Ie max.) At a lower setting it is correspondingly higher.  
Current Setting Ie  
F
The overload trip corresponds to a thermal overload relay in a motor starter conforming to IEC947-4-1. If a different value is prescribed (e.g.,  
reduced Ie for cooling medium having a temperature higher than 40 °C or a place of installation higher than 2000 m above sea level), the setting  
current is equal to the reduced rated current Ie of the motor.  
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
49  
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
Notes:  
50  
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
Approximate Dimensions  
Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes.  
Cat. No. 140M-C, -D  
Cat. No. 140M-C2…  
§
§
§
§
Cat. No. 140M-D8…  
§
§
§
§
Mounting on 35 mm DIN Rail  
Undervoltage/shunt trip  
Auxiliary contact (front mounted)  
§ Auxiliary contact (side mounted)  
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
51  
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
Cat. No. 140M-F  
Cat. No. 140M-F8…  
§
§
§
§
Mounting on 35 mm DIN rail  
Undervoltage/shunt trip  
Auxiliary contact (front mounted)  
Auxiliary contact (side mounted)  
§
Cat. No. 140M-RC, Screwless  
Cat. No. 140M-RC…  
§
§
§
§
Mounting on 35 mm DIN rail  
Undervoltage/shunt trip  
Auxiliary contact (front mounted)  
§ Auxiliary contact (side mounted)  
52  
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
Mounting position/safety clearance of Cat. No. 140M-C…, 140M-D…, 140M-F…  
Cat. No. 140M-C/D…  
Cat. No. 140M-F…  
90°  
3
0°  
Minimum distance to grounded parts or walls  
Cat. No. 140M-C-TE1 Type E adapter on Cat. No. 140M-C2E…  
Cat. No. 140M-C-TE1 Type E adapter on Cat. No. 140M-D8E…  
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
53  
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
Cat. No. 140M-C-TE1 Type E adapter on Cat. No. 140M-F8E…  
Screw Adapter 140M-C-N45 for 140M-C2/D8 and 140M-F8  
.
.
.
54  
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
Cat. No. 140M-C with Busbar  
§
Compact Busbar Feeder Terminal IEC  
Compact Busbar Feeder Terminal UL type E and IEC  
Mounting on 35 mm DIN Rail  
§ Top Hat Rail Adapter 10 mm  
140M-C-SHS Screw Adapter  
> 10 (25/64)  
205 (8-5/64)  
215 (8-31/64)  
245 (9-41/64)  
140M-C  
140M-D / 140U-D  
140M-F  
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
55  
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
140M-C-D…66  
4.5  
(0.18)  
min. 100  
(3.93)  
3.5  
(0.14)  
1.5...5  
0.06…0.19)  
35...45  
(1.4…1.8)  
b
53.5  
(2.10)  
53.5  
(2.10)  
140M-C-DS  
140M-C-DSL  
a
5
(0.19)  
4...8  
(0.16…0.31)  
c1  
5
(0.19)  
4.5  
(0.18)  
c2  
2.4  
(0.09)  
With Cat. No. 140-M-C-DS Shaft  
With Cat. No. 140-M-C-DSL Shaft  
b
Cat. No.  
140M-C  
a
b
c1  
c2  
a
c1  
c2  
105.5  
5
105.5  
5
117…338 (4.6…13.3)  
49.5 (1.95) 40.5 (1.6)  
117…438 (4.6…17.2)  
49.5 (1.95) 40.5 (1.6)  
(4.15 0.19)  
(4.15 0.19)  
140M-D 126…347 (4.96…13.66) 114.5 5 (4.5 0.19) 49.5 (1.95) 40.5 (1.6) 126…497 (4.96…19.56) 114.5 5 (4.5 0.19) 49.5 (1.95) 40.5 (1.6)  
148.6…369.6  
(5.85…14.55)  
137.1  
5
137.1  
5
140M-F  
59.35 (2.34) 50.35 (1.98) 148.6…519 (5.85…20.43)  
59.35 (2.34) 50.35 (1.98)  
(5.39 0.19)  
(5.39 0.19)  
140M-C-WBE  
56  
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
Cat. No. 198E…  
Ø
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
57  
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
Notes:  
58  
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
Motor Protection Circuit Breaker and Motor Circuit Protector Specifications  
Rockwell Automation Publication 140M-TD002G-EN-P - January 2018  
59  
Rockwell Automation Support  
Use the following resources to access support information.  
Knowledgebase Articles, How-to Videos, FAQs, Chat,  
User Forums, and Product Notification Updates.  
Technical Support Center  
www.rockwellautomation.com/knowledgebase  
www.rockwellautomation.com/global/support/get-support-  
now.page  
Local Technical Support Phone Numbers  
Locate the phone number for your country.  
Find the Direct Dial Code for your product. Use the  
code to route your call directly to a technical support  
engineer.  
www.rockwellautomation.com/global/support/direct-  
dial.page  
Direct Dial Codes  
Literature Library  
Installation Instructions, Manuals, Brochures, and  
Technical Data.  
www.rockwellautomation.com/literature  
Get help determining how products interact, check  
features and capabilities, and find associated  
firmware.  
Product Compatibility and Download Center  
(PCDC)  
www.rockwellautomation.com/global/support/pcdc.page  
Documentation Feedback  
Your comments will help us serve your documentation needs better. If you have any suggestions on how to improve this document, complete the  
How Are We Doing? form at http://literature.rockwellautomation.com/idc/groups/literature/documents/du/ra-du002_-en-e.pdf.  
Rockwell Automation maintains current product environmental information on its website at http://www.rockwellautomation.com/rockwellautomation/about-us/sustainability-ethics/product-environmental-compliance.page.  
Allen-Bradley, LISTEN. THINK. SOLVE, Rockwell Automation, and Rockwell Software are trademarks of Rockwell Automation, Inc.  
Trademarks not belonging to Rockwell Automation are property of their respective companies.  
Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 34752 İçereny, İstanbul, Tel: +90 (216) 5698400  
Publication 140M-TD002G-EN-P - January 2018  
Supersedes Publication 140M-TD002F-EN-P September 2016  
Copyright © 2018 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.  

相关型号:

140M-DRY66

HANDLE RED/YELLOW
ETC

140M-F-PNC37

CONNECTING MODULE 100-C30/C37
ETC

140M-F-PNC43

CONNECTING MODULE 100-C43
ETC

140M-F8E-C32

CIRCUIT BREAKER 23.0/32.0A
ETC

140M-F8E-C45

CIRCUIT BREAKER 32.0/45.0A
ETC

140MEX

IMPEDANCE MATCHING TRANSFORMER
ETC

140N

LOW PROFILE - P.C. BOARD MOUNT AUDIO TRANSFORMERS
HAMMOND

140NEX

IMPEDANCE MATCHING TRANSFORMER
ETC

140P

LOW PROFILE - P.C. BOARD MOUNT AUDIO TRANSFORMERS
HAMMOND

140P-102-JT

Fixed Resistor, Wire Wound, 3W, 1000ohm, 140V, 5% +/-Tol,
RCD

140P-113-GT20

Fixed Resistor, Wire Wound, 3W, 11000ohm, 140V, 2% +/-Tol, 20ppm/Cel,
RCD

140P-121-GB20

Fixed Resistor, Wire Wound, 3W, 120ohm, 140V, 2% +/-Tol, 20ppm/Cel,
RCD