700-FSM4UZ12 [ROCKWELL]

Multi-Delay Relay, DPDT, Momentary, 12VDC (Coil), 0.05s Adj Min, 216000s Adj Max, AC Output, DIN-Rail Mount,;
700-FSM4UZ12
型号: 700-FSM4UZ12
厂家: ROCKWELL INTERNATIONAL CORPORATION.    ROCKWELL INTERNATIONAL CORPORATION.
描述:

Multi-Delay Relay, DPDT, Momentary, 12VDC (Coil), 0.05s Adj Min, 216000s Adj Max, AC Output, DIN-Rail Mount,

光电二极管 继电器
文件: 总251页 (文件大小:15438K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Technical Data  
Relay and Timer Specifications  
Bulletin Number 700  
Topic  
Page  
149  
Topic  
Page  
2
NEMA Industrial Relays  
700-P Industrial Relays  
Summary of Changes  
151  
167  
172  
176  
181  
187  
188  
208  
213  
221  
223  
228  
233  
237  
246  
General Information  
3
700S-P and 700S-PK — Heavy-Duty Safety Control Relays  
700-N Industrial Relays  
General Purpose Relays  
9
700-HA General-purpose Relay  
700-HB Square Base Relay  
12  
700-R Sealed Switch Relays  
700-RTC — Solid-State Timing Relay  
IEC Control Relays  
22  
700-HD Flange Mount Square Base Relay  
700-HF Square Base Relay  
28  
32  
700-CF Control Relay  
700-HC Miniature Ice Cube Relay  
700-HK Slim Line Relay  
39  
700S-CF Control Relays  
44  
700-K Miniature Control Relays  
Solid-state Relays  
700-HL Terminal Block Relay  
700-HLF Terminal Block Timing Relay  
700-HP Slim Line Relay  
50  
60  
Solid-state Relay Glossary  
700-SC Ice Cube Relays  
64  
700-HPS Safety Control Relay  
700-HJ Magnetic Latching Relay  
700-HG Power Relay  
65  
700-SF Square Base Relays  
700-SH Hockey Puck Relays  
700-SK Slim Line Relays  
71  
75  
700-HHF Flange Mount Power Relay  
700-HTA Alternating Relay  
80  
83  
General Purpose Electronic Timers and Counters  
700-FE Economy Timing Relay  
700-FS High Performance Timing Relay  
700-HNC Miniature Timing Relay  
700-HNK Ultra-Slim Timing Relay  
700-HR Dial Timing Relays  
89  
92  
96  
103  
109  
116  
128  
133  
138  
700-HT Plug-in Timing Relay  
700-HV Timing Relay  
700-HX Multi-Function Digital Timing Relay  
Relay and Timer Specifications  
Summary of Changes  
This publication contains new and updated information as indicated in the following table.  
Topic  
Page  
16  
700-HA Relay - updated operating time descriptions  
700-HC Relay - updated status indicator footnote  
700-HC Relay - updated operating time description  
700-HK Relay - updated status indicator footnote  
700-HK Relay - updated operating time description  
700-HLF Relay - updated operating time description  
700-HP Relay - added jumper catalog numbers  
700-HP Relay - added dimension drawings  
700-HPF - updated catalog number explanation  
700-HV- updated standards information  
700-P - updated operating coils  
39  
42  
44  
46  
61  
65  
69  
117  
135  
157  
177  
205  
700-R - updated accessories  
700-CF - added Contact Rating Table from EN 60947-5-1  
2
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
General Information  
Contact Data Tables  
AC and DC Switching Capability  
NEMA  
Pilot  
Relay  
Type  
Contact  
Contact  
Contact  
Material  
20  
mA  
50  
mA  
100  
mA  
1 mA  
1 A  
3 A  
5 A 10 A 20 A 25 A 30 A 35 A  
Arrangement Style  
Duty(1)  
Up to 8 form X  
or 8 form Y  
A600  
P600  
700-CF  
cross stamped Ag  
24V  
AC  
DC  
AC  
Up to 8 form X  
or 8 form Y  
A600  
P600  
24  
V
700S-CF  
cross stamped Ag  
DC  
AC  
DC  
Up to 8 form X  
or 8 form Y  
A300  
Q300  
700-K  
700-P  
700-PK  
700-PH  
700-R  
bifurcated  
bifurcated  
single  
AgCu  
NiAg  
AgCdO  
AgCdO  
W
17V  
A600  
P600  
Up to 12 form  
X or 8 form Y  
10V  
AC  
DC  
2X A600  
2X P600  
(20 A Lighting  
AC  
Up to 12 form  
X or 8 form Y  
10V  
Load)  
DC  
AC  
Up to 6 form X  
or 4 form Y  
A600  
P600  
tandem  
10V  
(35 A Lighting  
Load)  
DC  
B300  
C600  
P300  
Up to 8 form A  
or form B  
AC  
DC  
sealed sw.  
5V  
5V  
Up to 4 form A  
or form B  
B600  
P300  
AC  
DC  
700-RTC  
700S-P  
sealed sw.  
bifurcated  
W
A600  
P600  
Up to 12 form  
X or 8 form Y  
NiAg  
10V  
AC  
(1) See NEMA Ratings and Test Values on page 5  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
3
Relay and Timer Specifications  
Contact Data Tables  
AC and DC Switching Capability  
NEMA  
Pilot  
Duty  
Relay  
Type  
Contact  
Arrangement Style  
Contact  
Contact  
Material  
10  
mA  
50  
mA  
100  
mA  
1 mA  
1 A  
3 A  
5 A  
10 A 20 A 25 A 30 A 35 A  
AC  
DC  
700-FE  
700-FS  
700-HA  
1 N.O.  
single  
single  
single  
AgCdO  
AgCdO  
AgNi  
D300  
B300  
B300  
10V  
(24V Max.)  
AC  
DC  
1, 2 form C  
2, 3 form C  
10V  
10V  
(24V Max.)  
AC  
DC  
(24V Max)  
AC  
DC  
(24V Max)  
700-HAX 2, 3 form C  
bifurcated Au/AgNi B300  
6V  
AC  
DC  
(24VMax.)  
700-HB  
2, 3 form C  
single  
single  
single  
single  
single  
single  
single  
single  
single  
single  
single  
AgNi  
Ag/Au  
AgNi  
B300  
10V  
AC  
DC  
C300  
Q300  
700-HC14 4 form C  
700-HC22 2 form C  
700-HC24 4 form C  
10V  
(30V Max.)  
B300  
Q300  
AC  
DC  
10V  
10V  
AC  
DC  
(30V Max.)  
C300  
Q300  
AgNi  
AC  
DC  
(24V Max)  
700-HD  
700-HF  
700-HG  
2, 3 form C  
AgCdO  
AgCdO  
AgNi  
B300  
B300  
A600  
A600  
B600  
B300  
10V  
10V  
10V  
10V  
10V  
AC  
DC  
(30V Max)  
2, 3, 4 form C  
AC  
DC  
(28V Max)  
1 form X, 1 form  
C, 2 form A, 2  
form C  
AC  
DC  
(28V Max)  
700-  
HHF45  
1 form X  
2 form C  
3 form C  
1, 2 form C  
AgNi  
AC  
DC  
700-  
HHF62  
AgNi  
(28V Max)  
AC  
DC  
(28V Max)  
700-  
HHF73  
AgNi  
10V  
AC  
DC  
700-HJ  
AgCdO  
AgNi  
10V  
10V  
(24V Max.)  
AC  
DC  
700-HK36 1 form C  
700-  
1 form C  
700-HK32 2 form C  
700-  
2 form C  
single  
single  
single  
single  
B300  
Au/AgNi B300  
AgNi B300  
Au/AgNi B300  
(30V Max)  
AC  
DC  
5V  
(30V Max)  
4
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Contact Data Tables  
AC and DC Switching Capability  
1 A 3 A 5 A 10 A  
NEMA  
Pilot  
Duty  
10  
mA  
50  
mA  
100  
mA  
Contact  
Contact Contact  
1 mA  
20 A 25 A 30 A 35 A  
Relay Type  
Arrangement Style  
Material  
Solid-State 1  
N.O.  
AC/  
DC  
700-HLS  
700-HLT  
3V  
B300  
R300  
6
A
1 Form C  
1 Form C  
2 Form C  
2 Form C  
single  
single  
single  
single  
AgSnO  
AgSnO  
AgNi  
12V  
AC/DC  
B300  
R300  
6
700-HLT_ _X  
700-HP  
8V  
5V  
AC/DC  
AC/DC  
AC/DC  
A
B300  
Q300  
8
A
(300 mW)  
AgNi +  
Gold  
B300  
Q300  
5V  
(50 mW)  
8
A
700-HPX  
AC  
DC  
(30V  
Max)  
700-HS  
700-HT  
2 Form C  
2 form C  
single  
single  
AgCdO  
AgNi  
B300  
B300  
10V  
AC  
DC  
(30V  
Max)  
10V  
NEMA Ratings and Test Values  
NEMA Ratings and Test Values for AC Control Circuit Contacts at 50 or 60 Hz  
Maximum Current [A]  
120V  
Make  
240V  
Make  
480V  
Make  
600V  
VA  
NEMA Contact Rating Thermal Continuous  
Designation  
Test Current [A]  
Break  
Break  
Break  
Make  
Break  
Make  
Break  
A150  
A300  
A600  
B150  
B300  
B600  
C150  
10  
10  
10  
5
60  
6.00  
6.00  
6.00  
3.00  
3.00  
3.00  
1.50  
1.50  
1.50  
0.60  
0.60  
0.30  
12  
30  
15  
12  
7200  
7200  
7200  
3600  
3600  
3600  
1800  
1800  
1800  
432  
720  
720  
720  
360  
360  
360  
180  
180  
180  
72  
60  
3.00  
3.00  
60  
30  
1.50  
1.20  
30  
15  
7.5  
3.75  
30  
6
5
30  
1.50  
1.50  
5
30  
15  
0.75  
0.60  
2.5  
2.5  
2.5  
1.0  
1.0  
0.5  
20  
20  
15  
7.5  
7.5  
1.8  
60  
3
C300  
15  
0.75  
0.75  
C600  
15  
0.375  
0.30  
D150  
D300  
D600  
2X A300  
2X A600  
3.60  
3.60  
1.80  
120  
120  
24  
0.30  
432  
72  
216  
36  
6.00  
6.00  
14400  
14400  
1440  
1440  
12  
60  
3.00  
2.40  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
5
Relay and Timer Specifications  
NEMA Ratings and Test Values for DC Control Circuit Contacts  
Maximum Current [A]  
Make or Break at 300V or less  
[VA]  
NEMA Contact Rating Designation  
Thermal Continuous Test Current [A]  
5…28V  
125V  
250V  
301…600V  
N150  
N300  
N600  
P150  
P300  
P600  
Q300  
Q600  
2X P600  
10  
10  
2.2  
2.2  
2.2  
1.1  
1.1  
1.1  
0.55  
0.55  
2.2  
275  
275  
275  
138  
138  
138  
69  
10  
10  
1.1  
10  
10  
1.1  
0.40  
5.0  
5.0  
5.0  
2.5  
2.5  
10  
5.0  
5.0  
5.0  
2.5  
2.5  
10  
0.55  
0.55  
0.27  
0.27  
1.1  
0.20  
0.11  
0.11  
0.40  
69  
275  
NEMA Definitions for Contact Arrangements  
Contact  
Arrangement  
Description  
Diagram  
A Form A contact arrangement is one that has single-pole, single-throw, normally open contacts. The function of this  
arrangement is to close a circuit when actuated.  
Form A  
Form B  
Form C  
Form X  
Form Y  
Form Z  
A Form B contact arrangement is one that has single-pole, single-throw, normally closed contacts. The function of this  
arrangement is to open a circuit when actuated.  
A Form C contact arrangement is one that has single-pole, double-throw contacts with three terminals - one for normally  
open, one for normally closed, and one common. The function of this arrangement is to transfer a circuit when actuated.  
A Form X contact arrangement is one that has single-pole, single-throw, normally open double-make contacts. The function  
of this arrangement is to close a circuit when actuated.  
or  
or  
A Form Y contact arrangement is one that has single-pole single-throw normally closed double-break contacts. The function  
of this arrangement is to open a circuit when actuated.  
A Form Z contact arrangement is one that has single-pole, double-throw, contacts with four terminals — two for normally  
open and two for normally closed. The function of this arrangement is to open one circuit and close the other.  
6
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Timing Relay Selection Criteria  
Single Function Timers: Timers that have only 1 timing mode (for example, ON-Delay or OFF-Delay).  
Multi-Function Timers: Timers that have 4…8 timing modes that are selected by turning the mode selection switch.  
RESET  
POWER  
ON  
OFF  
ON-Delay or (Delay on Operate)  
When power is applied continuously (or when power and a start signal are applied), the  
timing cycle begins. The output contacts change state after the time delay is completed.  
The contacts will return to their normal state when a reset signal is applied or power is  
removed.  
START SIGNAL  
ON  
OFF  
OUTPUT CHANGED STATE  
NORMAL STATE  
TIME DELAY  
RESET  
RESET  
RESET  
POWER  
ON  
OFF  
OFF-Delay or (Delay on Release)  
START SIGNAL  
ON  
OFF  
Power is applied continuously. When a start signal is applied, the output contacts change  
state immediately. When the start signal is removed, the timing cycle begins. The output  
contacts will return to their normal state once the time delay is completed. Reset will  
occur when a reset signal is applied or power is removed.  
OUTPUT CHANGED STATE  
NORMAL STATE  
TIME DELAY  
POWER  
ON  
OFF  
One Shot or (Repeat Cycle)  
START SIGNAL  
ON  
OFF  
Power is applied continuously. When a start signal is applied, the output contacts change  
state immediately and the timing cycle begins. The output contacts will return to their  
normal state once the time delay is completed. Reset will occur when a reset signal is  
applied or power is removed.  
OUTPUT CHANGED STATE  
NORMAL STATE  
TIME DELAY  
POWER  
ON  
OFF  
Repeat Cycle or (Flicker)  
START SIGNAL  
ON  
OFF  
Power is applied continuously. When a start signal is applied, the timing cycle begins.  
When the time delay is completed, the output contacts change state and the next timing  
cycle begins. This cycle will repeat until a reset signal is applied or power is removed.  
OUTPUT CHANGED STATE  
NORMAL STATE  
OFF  
TIME  
ON  
TIME  
OFF  
TIME  
ON  
TIME  
OFF  
TIME  
Flexibility  
Mounting — Timing relays are available in several different models. They can be plugged into the same socket as the relay, or use a separate plug-in  
socket mounting.  
Contacts — The contacts are of various types and ratings. See the appropriate specification pages for more details.  
Functionality — Timing relays with multi-range and multi-function capability are available. Allowing you to stock one relay to cover a wide variety  
of applications.  
External Trigger Switch — OFF-Delay, One-Shot, and other timer functions require an external trigger switch (from a relay or push button) to  
control the timing function. The external trigger switch will cause the timing function to start. In OFF-Delay, the trigger switch closes to energize  
the output and when the trigger switch opens the OFF-Delay starts to time out. At the end of the time delay, the output is de-energized and the  
output contacts return to their shelf state  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
7
Relay and Timer Specifications  
Surge Suppression Information  
Max.  
Max.  
Relay  
Contact  
Dropout  
Time  
Transient  
Voltage  
Relative to  
System  
Suppression  
Technique  
Photo  
Cat. No.  
For use with  
Voltage  
700-ADR  
700-HA, -HB,-HK, -HP (6…220V DC)  
700-HC (6…24V DC)  
Diode  
3X  
3
700-ADL1  
700-ADL1R  
700-ADL2  
700-ADL2R  
700-ADL3  
700-ADL3R  
700-AR1  
Diode + LED  
Diode + LED  
Diode + LED  
Diode + LED  
Diode + LED  
Diode + LED  
RC  
3X  
700-HB, -HA, -HK, -HP (6…24V DC)  
700-HC (28…60V DC)  
3X  
3X  
700-HB, -HA, -HK, -HP (28…60V DC)  
700-HC (110…220V DC)  
3X  
3X  
700-HB, -HA, -HK, -HP (110…220V DC)  
700-HB, -HA, -HC,-HK, -HP (6…24V AC/DC)  
700-HB,-HA, -HC,-HK, -HP (110…240V AC/DC)  
700-HB,-HA, -HC,-HK, -HP (6…24V AC)  
700-HB, -HA, -HC, -HK, -HP (110…240V AC)  
3X  
No Effect  
No Effect  
No Effect  
No Effect  
700-AR2  
RC  
6…10X  
3X  
700-AV1R  
700-AV3R  
700-CF built-in  
100-FSC  
Varistor + LED  
Varistor + LED  
Diode  
700-CF Relay  
100C, 700-CF  
R-C Ckt  
No Effect  
No Effect  
100-FSV  
100C, 700-CF  
MOV  
100-FSD  
100C, 700-CF  
100C, 700-CF  
Diode  
Diode  
70…95 ms 6…10X  
100-JE  
5X  
6…10X  
700-N5  
700-P, 700-N  
700-P, 700-N  
RC  
RC  
No effect  
No effect  
3X  
3X  
700-N24  
700-R Relay  
700-R built-in  
Diode  
RC  
6…10X  
3X  
199-FSMA1, FSMA2  
199-FSMA9, 10, 11  
700-P, 700-H, 700-CF, 700DC-R  
700-P, 700-H, 700-CF, 700DC-R  
No effect  
No effect  
MOV  
199-FSMZ  
700-P, 700-H, 700-CF, 700DC-R  
Diode  
5X  
8
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
General Purpose Relays  
Product Overview  
Bulletin No.  
700-HA  
General-purpose Relay  
700-HB  
700-HD  
700-HF  
Type  
General-purpose Relay  
General-purpose Relay  
General-purpose Relay  
Pin-style terminals  
Blade-style quick connect terminals  
Standard ON/OFF flag indicator  
Electrical schematic on face  
Standard ON/OFF flag indicator  
Electrical schematic on face  
Clear cover for visual inspection  
Square-base  
Flange-mounted  
Blade-style quick connect terminals  
Plug-in quick connect solder terminals  
Optional push-to-test  
Optional LED  
Features  
Clear cover for visual inspection  
Optional push-to-test and manual Optional push-to-test and manual Clear cover for visual inspection  
override  
Optional LED  
override  
Optional LED  
Contact Ratings  
Contact Form  
DPDT, 3PDT  
Single  
DPDT, 3PDT  
Single  
DPDT, 3PDT  
Single  
DPDT, 4 PDT  
Single  
Contact Type  
Contact Material  
AgNi, AgNi + Gold  
AgCdO  
AgCdO  
AgCdO  
Operating Current,  
Under Resistant Load,  
Max  
700-HA: 10 A  
700-HAX: 6 A  
15 A  
15 A  
10 A  
700-HA: 10V, 5 mA  
700-HAX: 6V 1 mA  
Permissible Load, min  
Coil Ratings  
10V, 10 mA  
10V, 10 mA  
5V, 100 mA  
AC: 6, 12, 24, 48, 110, 120, 230, 240,  
277V  
DC: 6, 12, 24, 36, 48, 60, 80, 110, 125, DC: 6, 12, 24, 48, 110V  
140, 220V  
AC: 6, 12, 24, 120, 240V  
AC: 6, 12, 24, 120, 208, 240V  
DC: 6, 12, 24, 48, 110V  
AC: 6, 12, 24, 120, 240V  
DC: 6, 12, 24, 48, 110V  
Coil Voltage  
80…110% of nom voltage at 50 Hz  
80…110% of nom voltage at 60 Hz  
80…110% of nom voltage at DC  
85…110% of nom voltage at 50 Hz  
85…110% of nom voltage at 60 Hz  
80…110% of nom voltage at DC  
Permissible Coil Voltage  
Variation  
Electrical Ratings  
Pole-to-pole: 2000V  
Contact-to-coil: 2000V  
Contact-to-frame: 2000V  
Pole-to-pole: 2500V  
Contact-to-coil: 4000V  
Contact-to-frame: 2500V  
Pole-to-pole: 2500V  
Contact-to-coil: 4000V  
Contact-to-frame: 2500V  
Pole-to-pole: 1500V  
Contact-to-coil: 1500V  
Contact-to-frame: 1500V  
Dielectric Withstand  
Voltage  
200,000 min  
500,000 min (DPDT)  
Electrical Service Life  
(Cycles)  
100,000 min  
100,000 min  
100,000 min  
Reference  
Certifications  
CE, cULus, cURus, CSA, Lloyds  
CE, cULus, cURus, CSA, Lloyds  
700-HN153, 700-HN154  
22  
CE, UR, CSA, Lloyds  
CE, UR, CSA  
700-HN100, 700-HN101, 700-HN125,  
700-HN126, 700-HN204, 700-HN205  
Socket Catalog Numbers  
Page  
28  
700-HN262, 700-HN264  
32  
12  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
9
Relay and Timer Specifications  
Bulletin Number 700-HC  
700-HK  
700-HL  
700-HP  
Type  
Interposing/Isolation Relay  
Interposing/Isolation Relay  
Interposing/Isolation Relay  
Interposing/Isolation Relay  
Blade-style terminals  
Ideal for PLC Interfaces  
Built-in Coil Surge Protection  
Fully Assembled Relay/Sockets  
Standard LED  
Relay or Solid-state Output  
Optional: Leakage Current  
Suppression Solution  
Standard ON/OFF flag indicator  
Electrical schematic on face  
Clear cover for visual inspection  
Optional push-to-test and  
manual override  
Optional pilot light  
Retainer clip (comes with socket)  
Low switching capacity  
PCB “Pin Style” mounting  
5 mm pin spacing  
Features  
Push-to-test and manual override  
Optional LED  
Contact Ratings  
Contact Form  
Contact Type  
DPDT,4PDT  
Single  
SPDT,DPDT  
Single  
SPDT 1 N.O. (SSR)  
Single  
DPDT  
Single  
Contact Material  
AgNi, AgNi + Gold  
AgNi, AgNi + Gold  
AgSnO  
AgNi, AgNi + Gold  
Operating Current,  
Under Resistant  
Load, Max  
10 A (DPDT)  
7 A (4PDT)  
6 A (SPDT), 2 A (SSR DC output),  
2 A (SSR AC output)  
8 A (DPDT), 16 A (SPDT)  
8 A  
10V, 10 mA (Gold),5V, 10 mA or  
25V, 2 mA (Silver)  
12V 6 mA (72 mW) Silver  
8V, 2.5 mA (20 mW)Gold  
5V 5 mA (50 mW) Gold,  
5V 5 mA (300 mW) Silver  
Permissible Load,  
min  
5V 60 mA (Silver), 5V 10 mA (Gold)  
Coil Ratings  
Coil Voltage  
AC: 6, 12, 24, 120, 240V  
DC: 6, 12, 24, 48, 110V  
AC: 6, 12, 24, 120, 240V  
DC: 6, 12, 24, 48, 110V  
AC: 12, 24, 48, 110, 120, 230, 240V  
DC: 12, 24, 48, 125, 230, 240V  
AC: 6, 12, 24, 120, 240V  
DC: 6, 12, 24, 48, 110V  
80…110% of nom voltage at 50 Hz 80…110% of nom voltage at 50 Hz 85…110% of nom voltage at 50 Hz 80…110% of nom voltage at 50 Hz  
80…110% of nom voltage at 60 Hz 80…110% of nom voltage at 60 Hz 85…110% of nom voltage at 60 Hz 80…110% of nom voltage at 60 Hz  
Permissible Coil  
Voltage Variation  
80…110% of nom voltage at DC  
73…110% of nom voltage at DC  
80…110% of nom voltage at DC  
73…150% of nom voltage at DC  
Electrical Ratings  
Pole-to-pole: 1000V  
Contact-to-coil: 2000V  
Contact-to-frame: 2000V  
Pole-to-pole: 1500V  
Contact-to-coil: 1500V  
Contact-to-frame: 1500V  
Pole-to-pole: 1000V  
Contact-to-coil: 4000V  
Contact-to-frame: 1500V  
Pole-to-pole: 2000V  
Contact-to-coil: 5000V  
Dielectric  
Withstand Voltage  
Electrical Service  
Life (Cycles)  
100,000 min  
100,000 min  
100,000 min  
100,000 min  
Reference  
Certifications  
CE, cULus, cURus, CSA, Lloyds  
700-HN103, 700-HN128, 700-HN104  
39  
CE, UL, UR, CSA  
CE, cURus, cULus, ABS  
CE, cULus, cURus, CSA, Lloyds  
700-HN123, 700-HN230  
64  
700-HN121, 700-HN221, 700-HN122,  
700-HN222, 700-HN223, 700-HN224  
Socket Catalog  
Numbers  
50  
Page Number  
44  
10  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Bulletin Number 700-HJ  
700-HG  
700-HHF  
Type  
Magnetic Latching Relay  
Power Relay  
Power Relay  
Panel mount with screw terminals  
Optional magnetic blowouts for switching DC  
loads  
Socket mounted  
Ideal for lighting applications  
Flange mounted  
Optional LED  
Features  
Optional snap action switch  
Contact Ratings  
Contact Form  
Contact Type  
SPDT,DPDT(Singleor Dual Coil)  
SPST-N.O.-DM, SPDT, DPST-N.O., DPDT  
SPST-NO-DM, DPDT,3PDT  
Single  
AgCdO  
Single  
AgNi  
Single  
AgNi  
Contact Material  
Operating Current,  
Under Resistant  
Load, Max  
10  
A
40  
A
20 A (3PDT), 25 A (DPDT), 30 A (SPDT)  
10V 50 mA  
10V 100 mA (3PDT)  
Permissible Load,  
min  
10V 50 mA  
10V 50 mA  
Coil Ratings  
Coil Voltage  
AC: 24V, 120V, 240V  
DC: 12V, 24V  
AC: 24V, 120V, 240V, 277V, 480V  
DC: 12V, 24V, 48V, 110V, 220V, 250V  
AC: 24V, 120V, 240V  
DC: 6V,12V,24V  
85…110% of nom voltage at 50 Hz  
85…110% of nom voltage at 60 Hz  
80…110% of nom voltage at DC  
85…110% of nom voltage at 50 Hz  
85…110% of nom voltage at 60 Hz  
80…110% of nom voltage at DC  
85…110% of nom voltage at 50 Hz  
85…110% of nom voltage at 60 Hz  
80…110% of nom voltage at DC  
Permissible Coil  
Voltage Variation  
Electrical Ratings  
Pole-to-pole: 1500V AC Contact-to-coil: 1500V  
AC Contact-to-frame: 1500V AC  
Pole-to-pole: 2200V AC Contact-to-coil: 2200V  
AC Contact-to-frame: 2200V AC  
Pole-to-pole: 2200V AC Contact-to-coil: 2200V  
AC Contact-to-frame: 2200V AC  
Dielectric  
Withstand Voltage  
Electrical Service  
Life (Cycles)  
100,000 minimum  
100,000 minimum  
100,000 minimum  
Reference  
Certifications  
CE, UR, CSA  
CE, UL, CSA  
CE, UR, CSA  
Socket Catalog  
Numbers  
700-HN153, 700-HN154  
71  
75  
80  
Page Number  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
11  
Relay and Timer Specifications  
700-HA General-purpose Relay  
10 A contact rating  
DPDT, 3PDT  
Pin-style terminals  
Standard ON/OFF flag indicator  
Options: LED, push-to-test and manual override, socket-mounted surge suppressor module, or  
multi-function timer  
Contact choices: standard silver nickel, or bifurcated silver nickel with gold plating  
(1)  
Tube Base Relay with PIN Terminals (Single Contact) — Mechanical ON/OFF Indicator Included  
Wiring Diagrams  
Description  
Contact Rating  
Coil Voltage  
Cat. No.(1)  
U.S./Canada  
International  
6V AC  
12V AC  
24V AC  
120V AC  
240V AC  
277V AC  
6V DC  
12V DC  
24V DC  
36V DC  
48V DC  
60V DC  
80V DC  
110V DC  
125V DC  
140V DC  
220V DC  
6V AC  
12V AC  
24V AC  
120V AC  
240V AC  
6V DC  
12V DC  
24V DC  
48V DC  
60V DC  
80V DC  
110V DC  
125V DC  
140V DC  
220V DC  
700-HA32A06  
700-HA32A12  
700-HA32A24  
700-HA32A1  
700-HA32A2  
700-HA32A27  
700-HA32Z06  
700-HA32Z12  
700-HA32Z24  
700-HA32Z36  
700-HA32Z48  
700-HA32Z60  
700-HA32Z80  
700-HA32Z1  
700-HA32Z01  
700-HA32Z3  
700-HA32Z2  
700-HA33A06  
700-HA33A12  
700-HA33A24  
700-HA33A1  
700-HA33A2  
700-HA33Z06  
700-HA33Z12  
700-HA33Z24  
700-HA33Z48  
700-HA33Z60  
700-HA33Z80  
700-HA33Z1  
700-HA33Z01  
700-HA33Z3  
700-HA33Z2  
DPDT  
2-pole  
2 Form C  
10 A  
Single AgNi Contact  
B300  
700-HN100  
Sockets  
700-HN125  
700-HN204  
3PDT  
3-pole  
3 Form C  
10 A  
B300  
Single AgNi Contact  
700-HN101  
700-HN205  
Sockets  
700-HN126  
(1) LED Option: Add suffix (-4) to the selected 700-HA Relay Cat. No., except for the 240V AC Units, add (-4L). Push-to-test, Manual Override, and LED Option: Add suffix (-3-4) to the selected 700-HA Relay Cat. No., except for the 240V  
AC units, add (-3-4L). Push-to-test and Manual Override option: Add suffix (-3) to the selected 700-HA relay.  
LED not available for 220V DC and 277V AC coils.  
(1) For Time Modules and Surge Suppressor Modules, see Accessories.  
12  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Tube Base Relay with PIN Terminals (Bifurcated Contacts with Gold Overlay) — Mechanical ON/OFF Indicator Included  
Wiring Diagrams  
U.S./Canada  
Description  
Contact Rating  
Coil Voltage  
Cat. No  
International  
6V AC  
700-HAX2A06  
700-HAX2A12  
700-HAX2A24  
700-HAX2A1  
700-HAX2A2  
700-HAX2A27Δ  
700-HAX2Z06  
700-HAX2Z12  
700-HAX2Z24  
700-HAX2Z36  
700-HAX2Z48  
700-HAX2Z1  
700-HAX2Z01  
700-HAX2Z3  
700-HAX3A06  
700-HAX3A12  
700-HAX3A24  
700-HAX3A1  
700-HAX3A2  
700-HAX3Z06  
700-HAX3Z12  
700-HAX3Z24  
700-HAX3Z48  
700-HAX3Z1  
700-HAX3Z01  
700-HAX3Z3  
12V AC  
24V AC  
120V AC  
240V AC  
277V AC  
6V DC  
DPDT  
2-Pole  
2 Form C  
Bifurcated AgNi Contacts with Gold Plating  
6 A  
12V DC  
24V DC  
36V DC  
48V DC  
110V DC  
125V DC  
140V DC  
6V AC  
700-HN100  
700-HN204  
Sockets  
700-HN125  
12V AC  
24V AC  
120V AC  
240V AC  
6V DC  
3PDT  
3-Pole  
3 Form C  
Bifurcated AgNi Contacts with Gold Plating  
6 A  
12V DC  
24V DC  
48V DC  
110V DC  
125V DC  
140V DC  
700-HN101  
700-HN205  
Sockets  
700-HN126  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
13  
Relay and Timer Specifications  
Accessories - 700-HA Relays  
Pkg.  
Qty.  
Photo  
Description  
Cat. No.  
Screw Terminal Tube Base Socket — Panel or DIN Rail Mounting; Guarded Terminal  
Construction. 8-Pin for use with DPDT 700-HA Relays, -HX Timing Relays, -HT (On-Delay), and -HRM, -HRC  
and -HV (Repeat Cycle) Timing Relays.  
10  
10  
700-HN100  
Screw Terminal Tube Base Socket — Panel or DIN Rail Mounting; Open Style Construction. 8-Pin for  
use with DPDT 700-HA Relays, -HT (On-Delay) and -HRM, -HRC, and -HV (Repeat Cycle) Timing Relays. No  
retainer clip required.  
700-HN125  
Screw Terminal Tube Base Sockets — Panel or DIN Rail Mounting; Guarded Terminal  
10  
10  
700-HN101  
700-HN126  
Construction. 11-pin for use with 3PDT 700-HA relays.  
Screw Terminal Tube Base Sockets — Panel or DIN Rail Mounting; Open Style Terminal  
Construction. 11-pin for use with 3PDT 700-HA relays. No retainer clip required.  
8-Pin Socket — Can Be Used With or Without Timing Attachment or Surge Suppressor  
Screw Terminal Tube Base Sockets — panel or DIN Rail mounting. Guarded terminal construction. Used with  
DPDT 700-HA Relays.  
10  
10  
700-HN204  
700-HN205  
11-Pin Socket — Can Be Used With or Without Timing Module or Surge Suppressor. Screw Terminal  
Tube Base Sockets — panel or DIN Rail mounting. Guarded terminal construction.  
Used with 3PDT 700-HA relays.  
DIN (#3) symmetrical hat rail  
35 x 7.5 x 1 m  
10  
199-DR1  
Photo  
Description  
Pkg. Qty. Cat. No.  
Diode Surge Suppressor Voltage Range: 6…220V DC used with 700-HN204 and 700-HN205 socket  
10  
700-ADR  
Diode with LED Surge Suppressor Voltage Range: 6…24V DC used with 700-HN204 and 700-HN205 socket 10  
700-ADL1R  
Diode with LED Surge Suppressor Voltage Range: 28…60V DC used with 700-HN204 and 700-HN205  
10  
700-ADL2R  
700-ADL3R  
700-AV1R  
700-AV3R  
socket  
Diode with LED Surge Suppressor Voltage Range: 110…220V DC used with 700-HN204 and 700-HN205  
socket  
10  
Varistor with LED Surge Suppressor Voltage Range: 6…24V AC used with 700-HN204 and 700-HN205  
socket  
10  
Varistor with LED Surge Suppressor Voltage Range: 110…240V AC used with 700-HN204 and 700-HN205  
socket  
10  
RC Surge Suppressor Voltage Range: 6…24V AC/DC used with 700-HN204 and 700-HN205 socket  
RC Surge Suppressor Voltage Range: 110…240V AC/DC used with 700-HN204 and 700-HN205 socket  
10  
10  
700-AR1  
700-AR2  
14  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Photo  
Description  
Pkg. Qty. Cat. No.  
Timing Module  
On-Delay or One-Shot selectable voltage range:  
12…24V AC/DC used with sockets that accept plug-in  
accessory modules.  
1
1
1
700-AT3  
On-Delay  
U (A1/A2)  
LED & R  
Timing Module  
t
On-Delay or One-Shot selectable voltage range:  
110…125V AC used with sockets that accept plug-in  
accessory modules.  
700-AT3A1  
700-AT3A2  
One-Shot  
U (A1/A2)  
LED & R  
Timing Module  
t
On-Delay or One-Shot selectable voltage range:  
230…240V AC used with sockets that accept plug-in  
accessory modules.  
1. 1 s  
0.05…1 s  
2. 10 s  
0.5…10 s  
5…100 s  
3. 100 s  
4. 10 min  
5. 100 min  
6. 10 hours  
0.5…10 min  
5…100 min  
0.5…10 h  
5…100 h  
1
700-HT3  
7. 100 hours  
8. LED Indicator  
Socket and Retainer Clip Reference  
Relay Type  
Socket  
Retainer Clip  
700-HN100  
700-HN125  
700-HN204  
700-HN157  
Not Required  
700-HN157  
700-HA32  
700-HAX2  
700-HN101  
700-HN126  
700-HN205  
700-HN157  
Not Required  
700-HN157  
700-HA33  
700-HAX3  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
15  
Relay and Timer Specifications  
Specifications - 700-HA Relays  
Attribute  
700-HA  
ElectricalRatings  
Pilot Duty Rating (1)  
NEMA B300  
RatedThermal Current (I  
)
HA = 10 A – 120V, 240V; HAX = 6 A – 120V, 240V  
th  
Rated Insulation Voltage (Ui)  
250V IEC – 300V UL/CSA  
Break  
Make  
Hp  
Inductive  
120VAC  
30 A  
15 A  
3 A  
1.5 A  
1/3  
1
Contacts  
240VAC  
General-purpose  
Resistive  
10 A, 240V AC  
10 A, 30V DC  
Min. Low Energy Permissible Load  
Permissible Coil Voltage Variation  
HA = 10V, 5 mA HAX = 5V, 2 mA  
Pickup: 80…110% of nom voltage at 50 Hz, 80…110% of nom voltage at 60 Hz, 80…110% of nom voltage at DC  
AC Coils  
Inrush  
Sealed  
DC Coils  
50 Hz  
3.3VA  
2.2VA  
60 Hz  
2.85VA  
1.9VA  
CoilConsumption 10ꢀ  
1.3 W  
Must Dropout Voltage  
20% of nom V AC; 10% of nom V DC  
50 MΩ (700-HA), 30 MΩ (700-HAX)  
Max. Contact Resistance  
Design Specification/TestRequirements  
Electrical  
Pole-to-Pole  
2000V  
2000V  
Contact to Coil  
ElectricalLife(Operating)  
100,000 min.  
Mechanical  
Degree of Protection (Open Type) IEC 529  
Mechanical Lifecycles (AC/DC)  
Switching Frequency Operations  
Coil Voltages  
IP 40  
> 20 x 106/ 50 x 10  
6
3600/HR  
See Product Selection  
Pickup  
12 ms  
12 ms  
4 Ops/s  
5 G  
Operating Time  
Dropout  
Maximum Operating Rate  
Vibration  
Endurance  
Operational  
Endurance  
Operational  
2.5 G  
50 G  
Shock  
9 G  
Environmental  
Construction  
Operating  
Storage  
AC/DC  
AC/DC  
–40…+70 °C (–40…+158 °F)  
–40…+100 °C (–40…+212 °F)  
Temperature  
Altitude  
2000 m (6560 ft)  
Insulating Material  
Enclosure  
Molded High-Dielectric Material  
Transparent Dust Cover  
700-HA:  
10 A – AgNi  
6 A – Bifurcated/Gold Plating AgNi  
In accordance with EN50 0005  
Contact Material  
700-HAX:  
Terminal Markings on Socket  
Sockets  
8-Pin Socket — 700-HN100, -HN125, -HN204, 11-Pin Socket — 700-HN101, -HN126, -HN205  
cURus Recognized (File No. E3125, Guide NLDX2/NLDX8), cULus Listed when used with 700-HN sockets noted (File No. E3125, Guide  
NLDX/NLDX7), CE Marked, CSA Certified, UR Certified (File 229473)  
Certifications  
Standards  
UL508, CSA C22.2 No. 14, EN 61810-1  
(1) See NEMA Ratings and Test Values on page 5  
16  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Relay Performance Graphs  
Load (kVA)  
Voltage DC (V)  
COS φ  
Contact life vs. AC1 load at 1,800 cycles/h  
Breaking capacity for DC1 load at 1,800 cycles/h  
Load reduction factor vs. cos φ  
A = load applied to one contact  
B = load applied to two contacts in series  
C = load applied to three contacts in series  
Specifications - 700-HT3 Time Module  
Attribute  
700-HT3  
ElectricalRatings  
Operating Voltage Range  
Power Consumption  
12…240V AC (50/60 Hz) 12…240V DC  
0.1 W(12V)  
1.0 W(230V)  
Mechanical  
Degree of Protection of Input (B1) Terminal  
Input Terminal Wire Range  
IP 20 (Guarded Terminal)  
2
2
2
2
1.0 x 0.2 mm …2.5 mm (24 …14 AWG)  
2.0 x 0.2 mm …1.5 mm (24…16 AWG)  
Input Terminal Torque Range  
Status Indicator  
0.45…0.8 N•m (4…7 lb•in)  
Red  
1%  
Repeat Accuracy (1)  
RecoveryTime  
<50 ms  
Three DIP switches, seven ranges (set from 5…100% of range):  
1 s, 10 s, 100 s, 10 min, 100 min, 10 h, 100 h  
Selectable Timing Ranges  
Selectable Timing Modes  
Three DIP switches, eight modes:  
1. PowerOn–Delay  
5. Signal Off-Delay  
6. Signal On-One-Shot  
2. Power On One-Shot  
3. Power On Repeat Cycle, On Start  
4. Signal On-Delay and Signal Off-Delay  
7. Signal Off-One-Shot  
8. Signal On and Signal Off Watchdog Monitor  
Adjustable Trimmer Scale Accuracy  
Environmental  
5% of Time Range  
Operating  
–20…+50 °C (–4 …+122 °F)  
–55…+85 °C (–67…+185 °F)  
2000 m (6560 ft)  
Temperature  
Storage  
Altitude  
Construction  
Enclosure  
Gray Plastic Housing  
Mounting with Socket Only  
Sockets  
8- or 11-Pin Socket with Module Plug  
700-HN204 (8-Pin with Plug), 700-HN205 (11-Pin with Plug)  
Certifications  
cURus Recognized (File No. E14843, Guide NRNT2/NRNT8), CE Marked  
UL508, CSA C22.2 No. 14, EN 61810-1  
Standards  
(1) At constant voltage and temperature.  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
17  
Relay and Timer Specifications  
Timing Charts - 700-HT3 Multi-function Time Module (t = Time Range 0.05 s…100 h)  
Terms:  
U is Power Input  
R is Relay Output  
S Signal, +A1 Socket, B1 Timer  
t is the resulting Time Delay (Red light-emitting diode)  
1. Power On-delay  
3. Power On Repeat Cycle, On Start  
Apply power (U) to timer. Relay contacts (R) change state after time delay (t) is complete.  
Apply power (U) to timer. Relay contacts (R) change state immediately and the time delay (t)  
begins. When the time delay is complete, the contacts return to their shelf state for time delay (t)  
(time on = time-off). This cycle repeats until the power is removed. Terminal B1 is not used in this  
mode.  
Contacts return to their shelf state when power is removed. Terminal B1 is not used in this mode.  
2. Power On One-shot  
4. Signal On-delay and Signal Off-delay  
Apply power (U) to timer. Relay contacts (R) change state immediately and the time delay begins.  
When the time delay (t) is complete, contacts return to their shelf state. Contacts return to their  
shelf state when power is removed. Terminal B1 is not used in this mode.  
Apply power (U) to timer. When the signal (S) is closed the time delay (t) begins, after the time  
delay is completed the relay contacts (R) change state. Opening the signal starts the time delay,  
after the time delay is completed the contacts return to their shelf state. If the signal is closed or  
opened before the time delay is complete, the time delay is reset. Contacts return to their shelf  
state when power is removed.  
Timing Charts -Cat. No. 700-HT3 Timing Modes, Time Description, Timing Charts, and DIP Switch Selections  
Terms:  
U is Power Input  
R is Relay Output  
S Signal, +A1 Socket, B1 Timer  
t is the resulting Time Delay (Red light-emitting diode)  
5. Signal Off-delay  
7. Signal Off One-shot  
Apply power (U) to timer. When the signal (S) is closed, the relay contacts (R) change state  
immediately. When the signal is opened, the time delay (t) begins. If the signal is closed before  
the time delay is complete, the time delay is reset and the relay remains energized. When the  
time delay is complete, the contacts return to their shelf state. Contacts return to their shelf state  
when power is removed.  
Apply power (U) to timer. When the signal (S) is closed and then opened, the relay contacts (R)  
change state immediately and the time delay (t) begins. After the time delay begins, opening or  
closing the signal will not reset the time delay. When the time delay is complete, the contacts  
return to their shelf state. Contacts return to their shelf state when power is removed.  
8. Signal On and Signal Off Watchdog Monitor  
Apply power (U) to timer. When the signal (S) is closed, the relay contacts (R) energize  
immediately and the time delay (t) begins. If the signal is opened before the time delay is  
complete, the relay remains energized and the time delay is reset. When the time delay is  
completed, the contacts return to their shelf state. If the signal is opened after the time delay is  
complete, the relay contacts energize immediately and the same time delay begins. Continuous  
cycling of the signal at a rate that is faster than the time delay causes the relay contacts to remain  
energized. Contacts return to their shelf state when power is removed.  
6. Signal On One-shot  
Apply power (U) to timer. When the signal (S) is closed, the relay contacts (R) change state  
immediately and the time delay (t) begins. After the time delay begins, opening or closing the  
signal will not reset the time delay. When the time delay is complete, the contacts return to their  
shelf state. Contacts return to their shelf state when power is removed.  
18  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Dimensions -700-HA Relays  
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.  
54.1  
(2-1/8)  
32.8  
(1-3/10)  
36.5  
(1-9/20)  
700-HA Relay  
12.5  
(1/2)  
1.0  
(0.04)  
6.2  
(15/64)  
50  
(1-63/64)  
5.2  
(13/64)  
35.0  
27.0  
(1.38)  
(1.06)  
7.5  
1000  
(39-3/8)  
(0.3)  
Cat. No. 199-DR1 DIN Mounting Rail Series B  
Cat. No. 199-DR4 DIN Mounting Rail Series B Has No Mounting Holes  
Cat. No.  
A
B
C
D
Approx. Shipping Wt.  
35  
(1-3/8)  
27  
(1-1/16)  
7.5  
(19/64)  
1.02  
(1/64)  
1.85 kg  
(4.07lb)(10/pkg)  
199-DR1  
35  
(1-3/8)  
27  
(1-1/16)  
15  
(19/32)  
2.3  
(3/32)  
3.68 kg  
(8 lb) (5/pkg)  
199-DR4  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
19  
Relay and Timer Specifications  
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.  
24.6  
(31/32)  
40.1  
(1-37/64)  
20.8  
(53/64)  
30.0  
(1-3/16)  
26  
(1-1/32)  
24.9  
(63/64)  
54.9  
(2-5/32)  
65.0  
(2-35/64)  
51.1  
(2-1/64)  
4.2  
(5/32)  
38.0  
(1-1/2)  
33.0  
(1-19/64)  
#4–40  
M3  
14.7  
(37/64)  
Cat. No. 700-HN100  
Panel Mounting  
Cat. No. 700-HN125  
2
2
Wire Size: 2 x 2.5 mm  
Wire Size: 2 x 2.5 mm  
Single Wire – Up to 12 AWG  
Single Wire – Up to #12 AWG  
2
2
Double Wire – 2 x 2.5 mm (#2–14 AWG…#2–20 AWG)  
(Either Solid or Stranded)  
Double Wire – 2 x 2.5 mm (#2-14 AWG… #2-20 AWG)  
(Either Solid or Stranded)  
Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)  
Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)  
26  
(1-1/32)  
30  
(1-3/16)  
65.0  
(2-35/64)  
38.0  
(1-1/2)  
#4-40  
M3  
Cat. No. 700-HN101  
Panel Mounting  
Cat. No. 700-HN126  
2
2
Wire Size: 2 x 2.5 mm  
Wire Size: 2 x 2.5 mm  
Single Wire – Up to #12 AWG  
2
Single Wire – Up to #12 AWG  
2
Double Wire – 2 x 2.5 mm (#2–14 AWG…#2–20 AWG)  
(Either Solid or Stranded)  
Double Wire – 2 x 2.5 mm (#2–14 AWG…#2–20 AWG)  
(Either Solid or Stranded)  
Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)  
Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)  
20  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.  
33.5  
(1.32)  
33.5  
(1.32)  
26.9  
(1.06)  
26.9  
(1.06)  
11.0 (0.43)  
11.0  
(0.43)  
20.4  
(0.80)  
20.4  
(0.80)  
77.5  
(3.05)  
3.2  
(0.13)  
77.5  
(3.05)  
49.7  
(1.96)  
49.7  
(1.96)  
3.2 (0.13)  
35.5  
(1.40)  
35.5  
(1.40)  
21.6  
(0.85)  
21.6  
(0.85)  
16.8  
(0.66)  
16.8  
(0.66)  
38.0  
(1.50)  
38.0  
(1.50)  
4.0 (0.16)  
4.0 (0.16)  
Cat. No. 700-HN204  
Cat. No. 700-HN205  
2
2
Wire Size: 2 x 2.5 mm  
Wire Size: 2 x 2.5 mm  
Single Wire – Up to #12 AWG  
Single Wire – Up to #12 AWG  
2
2
Double Wire – 2 x 2.5 mm (14 AWG… 20 AWG) Qty. 2 wires  
(Either Solid or Stranded)  
Double Wire – 2 x 2.5 mm (14 AWG …20 AWG) Qty. 2 wires  
(Either Solid or Stranded)  
Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)  
Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)  
38.0  
(1.50)  
54  
(2.13)  
6.3  
(0.25)  
10.5  
(0.41)  
Cat. No. 700-HT3  
2
Wire Size: 2 x 1.5 mm (#2 – 16 AWG…#1–20 AWG)  
(Either Solid or Stranded)  
Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
21  
Relay and Timer Specifications  
700-HB Square Base Relay  
15 A contact rating  
DPDT, 3PDT  
Blade-style quick connect /solder terminals (Faston 187 - 4.8 x 0.5 mm)  
Standard ON/OFF flag indicator  
Options: LED, push-to-rest, and manual override  
Wiring Diagrams  
U.S./Canada  
Coil  
Voltage  
Photo  
Description  
Contact Rating  
Cat. No.(1)  
International  
6V AC  
700-HB32A06  
700-HB32A12  
700-HB32A24  
700-HB32A1  
700-HB32A2  
700-HB32Z06  
700-HB32Z12  
700-HB32Z24  
12V AC  
24V AC  
120V AC  
240V AC  
6V DC  
32  
DPDT  
34  
31  
2-Pole  
15 A  
B300  
2 Form C  
Single AgCdO Contact  
12V DC  
24V DC  
Input  
48V DC  
700-HB32Z48  
Sockets  
700-HN154  
700-HN153  
110V DC  
6V AC  
700-HB32Z1  
700-HB33A06  
700-HB33A12  
700-HB33A24  
700-HB33A1  
700-HB33A2  
700-HB33Z06  
700-HB33Z12  
700-HB33Z24  
12V AC  
24V AC  
120V AC  
240V AC  
6V DC  
3PDT  
3-Pole  
15 A  
B300  
3 Form C  
Single AgCdO Contact  
12V DC  
24V DC  
Input  
48V DC  
700-HB33Z48  
700-HB33Z1  
Sockets  
700-HN154  
700-HN153  
110V DC  
(1) LED Option: Add suffix (-4) to the selected 700-HB Relay Cat. No., except for the 240V AC Units, add (-4L).  
Push-to-test, Manual Override, and LED Option: Add suffix (-3-4) to the selected 700-HB Relay Cat. No., except for the 240V AC units, add (-3-4L)  
Push-to-test and Manual Override option: Add suffix (-3) to the selected 700-HB relay.  
22  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Accessories - 700-HB Relays  
Photo  
Description  
Diode Surge Suppressor Voltage Range: 6…220V DC used with 700-HN204 and 700-HN205 socket  
Pkg. Qty. Cat. No.  
10  
700-ADR  
Diode with LED Surge Suppressor Voltage Range: 6…24V DC used with 700-HN204 and 700-HN205 socket 10  
700-ADL1R  
Diode with LED Surge Suppressor Voltage Range: 28…60V DC used with 700-HN204 and 700-HN205  
10  
700-ADL2R  
700-ADL3R  
700-AV1R  
700-AV3R  
socket  
Diode with LED Surge Suppressor Voltage Range: 110…220V DC used with 700-HN204 and 700-HN205  
socket  
10  
Varistor with LED Surge Suppressor Voltage Range: 6…24V AC used with 700-HN204 and 700-HN205  
socket  
10  
Varistor with LED Surge Suppressor Voltage Range: 110…240V AC used with 700-HN204 and 700-HN205  
socket  
10  
RC Surge Suppressor Voltage Range: 6…24V AC/DC used with 700-HN204 and 700-HN205 socket  
RC Surge Suppressor Voltage Range: 110…240V AC/DC used with 700-HN204 and 700-HN205 socket  
10  
10  
700-AR1  
700-AR2  
Timing Module  
On-Delay  
On-Delay or One-Shot selectable voltage range:  
1
1
1
700-AT3  
U (A1/A2)  
12…24V AC/DC used with sockets that accept plug-in  
t
accessory modules.  
LED & R  
Timing Module  
One-Shot  
On-Delay or One-Shot selectable voltage range:  
700-AT3A1  
700-AT3A2  
110…125V AC used with sockets that accept plug-in  
U (A1/A2)  
t
accessory modules.  
LED & R  
Timing Module  
On-Delay or One-Shot selectable voltage range:  
230…240V AC used with sockets that accept plug-in  
accessory modules.  
1. 1 s  
0.05 s…1 s  
0.5 s…10 s  
5 s…100 s  
2. 10 s  
3. 100 s  
4. 10 min  
5. 100 min  
6. 10 hours  
0.5 min…10  
min  
1
700-HT3  
5 min…100 min  
0.5 h…10 h  
7. 100 hours  
5 h…100 h  
8. LED Indicator  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
23  
Relay and Timer Specifications  
Photo  
Description  
Pkg. Qty.  
Cat. No.  
Screw Terminal Socket — Panel or DIN Rail Mounting. Guarded Terminal Construction  
11-blade socket for use with 700-HB relays. This socket has coil and contact separation as well as the  
ability to use optional plug-in modules (700-A__ accessories, LED, surge suppression, timing modules).  
10  
700-HN153  
Screw Terminal Base Socket — Panel or DIN Rail Mounting. Open Style Construction  
10  
10  
700-HN154  
199-DR1  
11-blade for use with 700-HB relays.  
DIN (#3) symmetrical hat rail  
35 x 7.5 x 1 m  
Retainer Clip  
For Cat. Nos. 700-HN154 Sockets with 700-HB Relays  
Secures relay in socket. Order must be for 10 clips or multiples of 10.  
10  
10  
700-HN156  
700-HN158  
Retainer Clip  
For Cat. Nos. 700-HN153 Sockets with 700-HB Relays  
Secures relay in socket. Order must be for 10 clips or multiples of 10.  
1492-MS5X12  
1492-MS6X9  
1492-MS6X12  
1492-MS8X9  
1492-MS8X12  
1492-MP-Blank  
Relay Identification Snap-in Markers  
Snap-in markers fit on top of product covers. The following are blank cards. Squares slip into molded slot 100  
on top of product covers.  
Pre-Printed Identification Tags — contains 10 sheets of pre-printed and blank tags. Each sheet  
contains 13 sets of the markings CR…9CR, TR…9TR, M…9M, F, R, 1S, and 117 blank tags. Tags are  
peel-off with sticky backing for easy placement on relays.  
10  
700-N40  
Blank Identification Tags — contains 10 sheets of blank identification tags for customer specialized  
printing. Each sheet contains 546 blank tags. Tags are peel-off with sticky backing for easy placement on 10  
relays.  
700-N41  
Socket and Retainer Clip Reference  
Relay Type  
Socket Cat. No.  
Retainer Clip Cat. No.  
700-HN153  
700-HN154  
700-HN158  
700-HN156  
700-HB  
24  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Specifications - 700-HB Relays  
Attribute  
700-HB  
ElectricalRatings  
Pilot Duty Rating (1)  
NEMA B300  
RatedThermal Current (I  
)
15 A – 120V, 240V  
250V IEC-300V UL/CSA  
th  
Rated Insulation Voltage (U )  
i
Make  
Break  
Hp  
Inductive  
2 -Pole  
60 A  
3 -Pole  
30 A  
2 -Pole  
6 A  
3 -Pole  
3 A  
Contacts  
120VAC  
3/4  
2
240VAC  
30 A  
15 A  
3 A  
1.5 A  
General-purpose  
Resistive  
15 A, 240V AC  
15 A, 30V DC  
1000 mW (10V, 10 mA)  
Min. Low Energy Permissible Load  
Permissible Coil Voltage Variation  
AC Coils  
80…110% of Nominal Voltage at 50 Hz  
80…110% of Nominal Voltage at 60 Hz  
80…110% of Nominal Voltage at DC  
50 Hz  
3.3VA  
2.2VA  
60 Hz  
2.85VA  
1.9VA  
Inrush  
Sealed  
DC Coils  
Coil Consumption  
10%  
1.3 W  
25%of VA  
10% of W  
50 MΩ  
Max. Allowable Leakage  
Max. Contact Resistance  
Design Specification/TestRequirements  
Mechanical  
Dielectric Withstand Voltage  
Pole-to-Pole  
2500V  
4000V  
Contact to Coil  
Degree of Protection (Open Type) IEC 529  
Mechanical lifecycles (AC/DC)  
Switching Frequency Operations  
Coil Voltages  
IP 40  
6
6
> 10 x 10 /30 x 10  
3600/HR  
See Overview/Product Selection  
Pickup  
Operating Time (ms)  
Dropout  
20 ms  
4 ms  
4 Ops/s  
5 G  
Maximum Operating Rate  
Endurance  
Vibration  
Operational  
1.5 G  
50 G  
Endurance  
Shock  
Operational  
15 G  
Environmental  
Construction  
Operating  
AC/DC  
AC/DC  
–40…+70 °C (–40…+158 °F)  
–40…+100 °C (–40…+212 °F)  
Temperature  
Storage  
Altitude  
2000 m (6560 ft)  
Insulating Material  
Enclosure  
Molded High Dielectric Material  
Transparent Dust Cover  
AgCdO  
Contact Material  
Terminal Markings on Socket  
Sockets  
In accordance with EN50 0005  
700-HN153, -HN154  
Certifications  
cURus Recognized (File No. E3125, Guide NLDX2/NLDX8), cULus Listed when used with 700-HN sockets noted  
UL508, CSA C22.2 No. 14, EN 61810-1  
Standards  
(1) See NEMA Ratings and Test Values on page 5  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
25  
Relay and Timer Specifications  
Technical Data - 700-HB Relays  
Load (kVA)  
Contact life versus AC1 load at 600 cycles/h.  
Voltage DC (V)  
Breaking capacity for DC1 load at 600 cycles/h.  
Load applied to one contact.  
A = for N.O. types  
B= other types  
(Highly Resistive)  
COS φ  
(Inductive)  
Load Reduction factor versus cos φ  
26  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Dimensions - 700-HB Relays  
Approximate Dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.  
60.9  
(2.40)  
30.25  
(1.19)  
35.8  
(1.41)  
38.2  
(1.50)  
27.0  
(1.06)  
40  
(1.57)  
34.3  
(1.35)  
Ø 3.2  
(0.13)  
91.3  
(3.59)  
51.4  
(2.02)  
35.4  
(1.39)  
95.3  
(3.75)  
46.3  
(1.82)  
21.6  
(0.85)  
32.0  
(1.26)  
35.5  
(1.40)  
700-HB Relay  
Cat. No. 700-HN153  
2
Wire Size: 2 x 2.5 mm  
Single Wire – Up to #12 AWG  
2
Double Wire – 2 x 2.5 mm (14 AWG… 20 AWG), Qty. 2 wires  
(Either Solid or Stranded)  
Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)  
49.5  
(1.95)  
25.6  
(1.01)  
35.4  
(1.40)  
38.0  
(1.50)  
84.85  
(3.34)  
54  
(2.13)  
84.3  
(3.32)  
41.5  
(1.63)  
6.3  
4.0  
(0.16)  
(0.25)  
10.5  
(0.41)  
Cat. No. 700-HN154  
Wire Size: 2 x 2.5 mm  
Cat. No. 700-HT3  
2
2
Wire Size: 2 x 1.5 mm (#2 – 16 AWG…#1–20 AWG)  
(Either Solid or Stranded)  
Single Wire – Up to #12 AWG  
2
Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)  
Double Wire – 2 x 2.5 mm (14 AWG… 20 AWG), Qty. 2 wires  
(Either Solid or Stranded)  
Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
27  
Relay and Timer Specifications  
700-HD Flange Mount Square Base Relay  
Flange-mounted/panel-mounted  
15 A contact rating  
DPDT, 3PDT  
Blade-style quick connect terminals (0.187 x 0.020)  
Solder terminals (no socket required)  
Wiring Diagrams  
U.S./Canada  
Photo  
Contact Rating  
Coil Voltage  
Cat. No.  
International  
6V AC  
700-HD32A06  
700-HD32A12  
700-HD32A24  
700-HD32A1  
700-HD32A20  
700-HD32A2  
700-HD32Z06  
700-HD32Z12  
700-HD32Z24  
700-HD32Z48  
700-HD32Z1  
700-HD33A06  
700-HD33A12  
700-HD33A24  
700-HD33A1  
700-HD33A20  
700-HD33A2  
700-HD33Z06  
700-HD33Z12  
700-HD33Z24  
700-HD33Z48  
700-HD33Z1  
12V AC  
24V AC  
120V AC  
208V AC  
240V AC  
6V DC  
32  
DPDT  
2-Pole  
34  
31  
15 A  
2 Form C  
AgCdO Contacts  
12V DC  
24V DC  
48V DC  
110V DC  
6V AC  
Input  
12V AC  
24V AC  
120V AC  
208V AC  
240V AC  
6V DC  
3PDT  
3-Pole  
15 A  
3 Form C  
AgCdO Contacts  
12V DC  
24V DC  
48V DC  
110V DC  
Input  
Accessories - 700-HD Relays  
Photo  
Pkg.  
Qty.  
Description  
Cat. No.  
1492-MS5X12  
1492-MS6X9  
1492-MS6X12  
1492-MS8X9  
1492-MS8X12  
1492-MP-Blank  
Relay Identification Snap-in Markers  
Snap-in markers fit on top of product covers. The following are blank cards. Squares slip into molded slot on top of  
product covers.  
100  
Pre-Printed Identification Tags — contains 10 sheets of pre-printed and blank tags. Each sheet contains 13 sets  
of the markings CR…9CR, TR…9TR, M…9M, F, R, 1S, and 117 blank tags. Tags are peel-off with sticky backing for 10  
easy placement on relays.  
700-N40  
700-N41  
Blank Identification Tags — contains 10 sheets of blank identification tags for customer specialized printing.  
Each sheet contains 546 blank tags. Tags are peel-off with sticky backing for easy placement on relays.  
10  
28  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Specifications  
Attribute  
- 700-HD Relays  
700-HD  
ElectricalRatings  
Pilot Duty Rating (1)  
Rated Thermal Current (I  
NEMA B300  
15 A(2) – 120V  
)
15 A (2) – 240V,  
th  
Rated Insulation Voltage(Ui)  
Inductive  
250V IEC-300V UL/CSA  
Make  
Break  
Hp  
2-Pole  
60 A  
3-Pole  
30 A  
2-Pole  
6 A  
3-Pole  
3 A  
120VAC  
3/4  
2
Contacts  
240VAC  
30 A  
15 A  
3 A  
1.5 A  
General-purpose  
Resistive  
15 A, 240V AC  
15 A, 30V DC  
Min. Low Energy Permissible Load  
Permissible Coil Voltage Variation  
AC Coils  
1000 mW (10V, 10 mA)  
80…110% of Nominal Voltage at 50 Hz  
80…110% of Nominal Voltage at 60 Hz  
80…110% of Nominal Voltage at DC  
50 Hz  
3.3VA  
2.2VA  
60 Hz  
2.85VA  
1.9VA  
Inrush  
Sealed  
DC Coils  
Coil Consumption  
10%  
1.3 W  
Maximum Contact Resistance  
Must Dropout Voltage  
50 MΩ  
20% of Nominal V AC  
10% of Nominal V DC  
Design Specification/Test Requirements  
Electrical  
Pole-to-Pole  
Contact to Coil  
2500V  
4000V  
Dielectric Withstand  
Voltage  
Mechanical  
Degree of Protection (Open Type) IEC 529  
Mechanical lifecycles (AC/DC)  
Switching Frequency Operations  
Coil Voltages  
IP 40  
See Overview/Product Selection  
3600/HR  
6
6
> 10 x 10 / 30 x 10  
Pickup  
Operating Time  
20 ms  
4 ms  
Dropout  
Maximum Operating Rate  
4 Ops/s  
Minimum Low Energy Permissible Load  
1000 mN (10V, 10 mA)  
Environmental  
Operating  
–40…+70 °C (–40…+158 °F)  
–40…+100 °C (–40…+212 °F )  
2000 m (6560 ft)  
Temperature  
Storage  
Altitude  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
29  
Relay and Timer Specifications  
Attribute  
700-HD  
Construction  
Insulating Material  
Enclosure  
Molded High Dielectric Material  
Transparent Dust Cover  
Contact Material  
Terminal Markings  
Certifications  
Standards  
Silver Cad. Ox.  
In accordance with EN50 0005  
cURs Recognized (File No. E3125, Guide NLDX2/NLDX8), CSA Certified (File No. 229473), CE Marked, UR Certified  
UL 508, CSA C22.2 No. 14, EN 61810-1  
(1) See NEMA Ratings and Test Values on page 5.  
(2) 3-pole relays have a 20 A maximum total current rating for all three poles.  
Voltage DC (V)  
Load (kVA)  
Contact life versus AC1 load at 600 cycles/h.  
Breaking capacity for DC1 load at 600 cycles/h.  
Load applied to one contact.  
A = for N.O. types  
B = other types  
(Highly Resistive)  
COS φ  
(Inductive)  
Load Reduction factor versus cos φ  
30  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Dimensions - 700-HD Relays  
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.  
35.9  
(1.41)  
63  
(2.48)  
68  
(2.67)  
38.2  
(1.50)  
700-HD Relay  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
31  
Relay and Timer Specifications  
700-HF Square Base Relay  
12 A contact rating  
DPDT, 4PDT  
Plug-in quick connect/solder terminals  
Options: LED, push-to-test manual override operator  
Blade size: 4.8 x 0.5 mm (0.19 x 0.02 in.)  
Wiring Diagrams  
U.S./Canada  
Contact  
Description  
Photo  
Coil Voltage  
Cat. No.(1)  
Rating  
International  
6V AC  
700-HF32A06  
700-HF32A12  
700-HF32A24  
700-HF32A1  
700-HF32A2  
700-HF32Z06  
700-HF32Z12  
700-HF32Z24  
700-HF32Z48  
12V AC  
24V AC  
120V AC  
240V AC  
6V DC  
DPDT  
2-pole  
2 Form C  
AgCdO  
Contacts  
12 A  
12V DC  
24V DC  
48V DC  
700-HN116  
700-HN262  
700-HN116  
700-HN262  
Socket  
110V DC  
700-HF32Z1  
6V AC  
700-HF34A06  
700-HF34A12  
700-HF34A24  
700-HF34A1  
700-HF34A2  
700-HF34Z06  
700-HF34Z12  
700-HF34Z24  
700-HF34Z48  
12V AC  
24V AC  
120V AC  
240V AC  
6V DC  
4PDT  
4-pole  
4 Form C  
AgCdO Contact  
12 A  
12V DC  
24V DC  
48V DC  
700-HN139  
700-HN264  
700-HN139  
700-HN264  
Socket  
110V DC  
700-HF34Z1  
(1) Pilot Light Option: Add suffix (-4) to the selected 700-HF Relay Cat. No. except for the 240V AC units, add (-4L).  
Manual Operator and LED Option: Add suffix (-3-4) to the selected 700-HF Relay Cat. No., except for the 240V AC units, add (-3-4L).  
32  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Accessories - 700-HF Relays  
Photo  
Description  
Pkg. Qty. Cat. No.  
Pre-Printed Identification Tags — contains 10 sheets of pre-printed and blank tags. Each sheet contains 13  
sets of the markings CR…9CR, TR…9TR, M…9M, F, R, 1S, and 117 blank tags. Tags are peel-off with sticky  
backing for easy placement on relays.  
10  
10  
700-N40  
700-N41  
Blank Identification Tags — contains 10 sheets of blank identification tags for customer specialized printing.  
Each sheet contains 546 blank tags. Tags are peel-off with sticky backing for easy placement on relays.  
Screw Terminal Socket — Panel or DIN Rail Mounting 8-blade miniature socket for use with DPDT HF  
relays.  
10  
700-HN116  
Screw Terminal Socket — Panel or DIN Rail Mounting, Guarded Terminal Construction  
8-blade socket for use with DPDT 700-HF relays. The socket has the ability to use optional plug-in modules (Cat.  
No. 700-A_ _ accessories, LED, surge suppression, timing modules).  
10  
700-HN262  
Screw Terminal Socket — Panel or DIN Rail Mounting, Guarded Terminal Construction  
14-blade socket for use with 4PDT 700-HF relays.  
10  
700-HN139  
Screw Terminal Socket — Panel or DIN Rail Mounting, Guarded Terminal Construction  
14-blade socket for use with 4PDT 700-HF relays. The socket has coil and contact separation and the ability to use 10  
optional plug-in modules (Cat. No. 700-A_ _ accessories, LED, surge suppression, timing modules).  
700-HN264  
DIN (#3) symmetrical hat rail  
35 x 7.5 x 1 m  
10  
199-DR1  
Retainer Clip for Cat. Nos. 700-HN103, -HN104 and -HN128 Sockets with 700-HC Relays and Cat. Nos.  
700-HN116, 700-HN262 Sockets with 700-HF DPDT Relays§  
10  
10  
700-HN114  
700-HN266  
Secures relay in socket. Order must be for 10 clips or multiples of 10.  
Retainer Clip for Cat. Nos. 700-HN139 and -HN264 Sockets with 700-HF 4PDT Relays§  
Secures relay in socket. Order must be for 10 clips or multiples of 10.  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
33  
Relay and Timer Specifications  
Accessories - 700-HF Relays  
Photo  
Description  
Pkg. Qty. Cat. No.  
Diode with LED Surge Suppressor  
10  
10  
10  
10  
700-ADL1  
700-ADL2  
700-ADL3  
700-AV1R  
Voltage Range: 6…24V DC used with sockets that accept plug-in accessory modules.  
Diode with LED Surge Suppressor  
Voltage Range: 28…60V DC used with sockets that accept plug-in accessory modules.  
Diode with LED Surge Suppressor  
Voltage Range: 110…220V DC used with sockets that accept plug-in accessory modules.  
Varistor with LED Surge Suppressor  
Voltage Range: 6…24V AC used with sockets that accept plug-in accessory modules.  
Varistor with LED Surge Suppressor  
Voltage Range: 110…240V AC used  
10  
10  
10  
700-AV3R  
700-AR1  
700-AR2  
700-AT3  
with sockets that accept plug-in accessory modules.  
RC Surge Suppressor  
Voltage Range: 6…24V AC/DC used  
with sockets that accept plug-in accessory modules.  
RC Surge Suppressor  
Voltage Range: 110…240V AC/DC used  
with sockets that accept plug-in accessory modules.  
Timing Module  
On-Delay or One-Shot selectable voltage range: 12…24V AC/DC  
used with sockets that accept plug-in accessory modules.  
Timing Module  
On-Delay or One-Shot selectable voltage range: 110…125V AC  
used with sockets that accept plug-in accessory modules.  
700-AT3A1  
1
Timing Module  
On-Delay or One-Shot selectable voltage range: 230…240V AC  
used with sockets that accept plug-in accessory modules.  
700-AT3A2  
Socket, and Retainer Clip Reference  
Relay Type  
Cat. No. Socket  
Cat. No. Retainer Clip  
700-HN116  
700-HN262  
700-HF32  
700-HN114  
700-HN139  
700-HN264  
700-HF34  
700-HN266  
34  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Specifications- 700-HF Relays  
Electrical Ratings  
700-HF 2 Pole  
700-HF 4 Pole  
AC 15 @ 700 VA  
AC-1 @ 3000 VA  
230V AC  
Inductive V AC  
1 Hp @ 240V AC  
120V AC  
DC-1  
1/2 Hp @ 120V AC  
12 A @ 30V DC  
Contacts  
VDC  
0.5 A @ 110V DC  
0.25 A @ 220V DC  
AC  
12 A @ 250 V AC (per pole)  
12 A @ 30 V DC (per pole)  
80…110% nom voltage  
Resistive  
Operating Range  
Rated Power  
DC  
AC  
DC  
80…110% nom voltage  
85…110% nom voltage  
AC (50 Hz)  
1.5 VA  
1 W  
2 VA  
DC  
AC  
DC  
AC  
DC  
1.3 W  
80% nom voltage  
60% nom voltage  
20% nom voltage  
10% nom voltage  
250V AC  
Holding Voltage  
Must Drop Out Voltage  
Insulation Voltage  
Design Specification/Test Requirements  
Pole-to-Pole  
2500V AC  
2500V AC  
Dielectric Withstand Voltage  
Contact to Pole  
Mechanical  
Degree of Protection  
Mechanical Life Operations  
Switching Frequency Operations  
Coil Voltages  
Open Type (Sockets)  
20 x 106  
3600/hr  
See Product Selection  
Pickup  
8 ms  
3 ms  
10 ms  
4 ms  
Operating Time at nom voltage  
at 20 °C  
Dropout  
Maximum Operating Rate  
Vibration  
4 Ops/s  
15 G  
Shock  
15 G  
Environmental  
Operating  
Storage  
–40…+70 °C (–40…+268 °F)  
–50…+80 °C (–89…+176 °F)  
2000 m (6560 ft)  
Temperature  
Altitude  
Construction  
Insulating Material  
Enclosure  
Molded High-Dielectric Material  
Transparent Dust Cover  
Contact Material  
Terminal Markings on Socket  
Sockets  
Silver Cad. Oxide  
In accordance with EN50 0005  
8-Blade Socket (DPDT) Cat. No. 700-HN116 & 700-HN262, 14-Blade Socket (4PDT) Cat. No. 700-HN139 & 700-HN264  
CSA Certified (File No. 229473), UL Recognized (File No. E3125, Guide NLDX2/NLDX8), CE Marked,  
Certifications  
Standards  
UL Listed when used with sockets shown above, (File No. E3125, Guide NLDX/NLDX 7), LR Certified, RINA Certified, IMQ Certified  
UL 508, CSA 22.2 No. 14, EN-61810-1  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
35  
Relay and Timer Specifications  
Dimensions -700-HF Relays  
Approximate Dimensions are shown in millimeters (inches). Approximate Dimensions are not intended to be used for manufacturing purposes.  
700-HF Relay (DPDT)  
700-HF (4PDT)  
Cat. No. 199-DR1 DIN Mounting Rail Series B  
Cat. No. 199-DR4 DIN Mounting Rail Series B Has No Mounting Holes  
Approx.  
Shipping Wt.  
Cat. No.  
199-DR1  
199-DR4  
A
B
C
D
35  
(1-3/8)  
27  
(1-1/16)  
7.5  
(19/64)  
1.02  
(1/64)  
1.85 kg  
(4.07 lb) (10/pkg)  
35  
(1-3/8)  
27  
(1-1/16)  
15  
(19/32)  
2.3  
(3/32)  
3.68 kg  
(8 lb) (5/pkg)  
36  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Dimensions - 700-HF Relays  
Approximate Dimensions are shown in millimeters (inches). Approximate Dimensions are not intended to be used for manufacturing purposes.  
Cat. No. 700-HN116  
Wire Size: 2 x 2.5 mm2  
Single Wire – Up to #12 AWG  
Double Wire – 2.5 mm2 (14 … 20 AWG), Qty. 2 wires  
(Either Solid or Stranded)  
Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)  
Cat. No. 700-HN262  
Wire Size: Solid - 1x6/ 2 x 2.5 mm2  
1x10 / 2 x 14 AWG  
Stranded - 1x4 / 2x2.5 mm2  
1x12 / 2x14 AWG  
Length: 9 mm (3/8 in.) - Torque: 0.8 N•m (7 lb• in)  
300V AC, 12 A, 50 °C  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
37  
Relay and Timer Specifications  
Cat. No. 700-HN139  
Wire Size: 2 x 2.5 mm2  
Single Wire – Up to #12 AWG  
Double Wire – 2.5 mm2 (14 … 20 AWG), Qty. 2 wires  
(Either Solid or Stranded)  
Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)  
Cat. No. 700-HN264  
Wire Size: Solid - 1x6/ 2 x 2.5 mm2  
1x10 / 2x14 AWG  
Stranded - 1x4 / 2x2.5 mm2  
1x12 / 2x14 AWG  
Length: 9 mm (3/8 in.) - Torque: 0.8 N•m (7 lb•in)  
300V AC, 10 A, 70 °C  
38  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
700-HC Miniature Ice Cube Relay  
7 or 10 A contact ratings  
2PDT or 4PDT  
Standard ON/OFF flag indicator  
Blade-style terminals (2.0 x 0.5 mm)  
Choice of standard silver nickel contacts, or silver nickel with gold-plated contacts for low-energy applications  
Options: LED, push-to-test with manual override option  
Tungsten UL Approvals  
4-Pole: 5A @ 24V DC  
2-Pole: 10A @ 24V DC  
Wiring Diagrams  
U.S./Canada  
Photo  
Contact Rating  
Coil Voltage Cat. No.(1)  
International  
12V DC  
24V DC  
24V AC  
700-HC22Z12  
700-HC22Z24  
700-HC22A24  
2PDT  
10 A  
2-Pole  
C300  
2 Form C  
Contacts:  
10 A = AgNi  
Contacts  
R300  
Low energy rating;  
(10V, 10 mA)  
100 mW  
120V AC  
700-HC22A1  
Input  
700-HN103  
700-HN104  
700-HN128  
240V AC  
700-HC22A2  
6V AC  
700-HC14A06  
700-HC14A12  
700-HC14A24  
700-HC14A1  
700-HC14A2  
700-HC14Z06  
700-HC14Z12  
700-HC14Z24  
700-HC14Z48  
700-HC14Z1  
700-HC24A06  
700-HC24A12  
700-HC24A24  
700-HC24A1  
700-HC24A2  
700-HC24Z06  
700-HC24Z12  
700-HC24Z24  
700-HC24Z48  
700-HC24Z1  
12V AC  
24V AC  
120V AC  
240V AC  
6V DC  
4PDT  
4-Pole  
4 Form C  
Contacts:  
7 A  
Low energy rating;  
(5V, 10 mA or 25V, 2 mA)  
50 mW  
7A = AgNiAu  
Gold Plated  
Contacts  
12V DC  
24V DC  
48V DC  
110V DC  
6V AC  
12V AC  
24V AC  
120V AC  
240V AC  
6V DC  
Input  
4PDT  
7 A  
4-Pole  
C300  
4 Form C  
Contacts:  
R300  
Low energy rating;  
(10V, 10 mA)  
100 mW  
7A = AgNi  
Silver Contacts  
12V DC  
24V DC  
48V DC  
110V DC  
700-HN103  
700-HN104  
700-HN128  
(1) LED Option: Add suffix (-4) to the selected 700-HC Relay catalog number, except for the 240V AC units, add (-4L).  
Push-to-test, Manual Override, and LED Option: Add suffix (-3-4) to the selected 700-HC catalog number, except for the 240V AC units, add (-3-4L).  
Push-to-test and Manual Override option: Add suffix (-3) to the selected 700-HC relay catalog number.  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
39  
Relay and Timer Specifications  
Accessories - 700-HC Relays  
Photo  
Pkg.  
Qty.  
Description  
Cat. No.  
Diode with LED Surge Suppressor  
Voltage Range: 6…24V DC  
used with 700-HN104 socket  
10  
10  
10  
10  
10  
10  
10  
700-ADL1  
Diode with LED Surge Suppressor  
Voltage Range: 28…60V DC  
used with 700-HN104 socket  
700-ADL2  
700-ADL3  
700-AV1R  
700-AV3R  
700-AR1  
Diode with LED Surge Suppressor  
Voltage Range: 110…220V DC  
used with 700-HN104 socket  
Varistor with LED Surge Suppressor  
Voltage Range: 6…24V AC  
used with 700-HN104 socket  
Varistor with LED Surge Suppressor  
Voltage Range: 110…240V AC  
used with 700-HN104 socket  
RC Surge Suppressor  
Voltage Range: 6…24V AC/DC  
used with 700-HN104 socket  
RC Surge Suppressor  
Voltage Range: 110…240V AC/DC  
used with 700-HN104 socket  
700-AR2  
Timing Module  
On-Delay or One-Shot selectable voltage range: 12…24V AC/DC used  
with sockets that accept plug-in accessory modules.  
700-AT3  
Timing Module  
On-Delay or One-Shot selectable voltage range: 110…125V AC used  
with sockets that accept plug-in accessory modules.  
1
700-AT3A1  
700-AT3A2  
Timing Module  
On-Delay or One-Shot selectable voltage range: 230…240V AC used  
with sockets that accept plug-in accessory modules.  
Screw Terminal Socket — Panel or DIN Rail Mounting; Guarded Terminal Construction.Ith = 10 A per pole. 14-blade  
miniature socket for use with 700-SC Relays.  
10  
700-HN103  
Screw Terminal Socket — Panel or DIN Rail Mounting; Guarded Terminal Construction Ith = 10 A per pole. 14-blade  
miniature socket for use with 700-HC relays. This socket has coil and contact separation as well as the ability to plug in 10  
optional plug in modules (700-A__ accessories: LED, Surge Suppression, Timing Modules)  
700-HN104  
700-HN128  
Screw Terminal Base Socket — Panel or DIN Rail Mounting; Open-Style Construction Ith = 10 A per pole. 14-blade  
miniature socket for use with 700-HC Relays.  
10  
40  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Photo  
Pkg.  
Qty.  
Description  
Cat. No.  
DIN (#3) symmetrical hat rail  
35 x 7.5 x 1 m  
10  
199-DR1  
Retainer Clip for Cat. Nos. 700-HN103, -HN104 and -HN128 Sockets with 700-HC Relays.  
10  
10  
700-HN114  
700-HN124  
Secures relay in socket.(1)  
Plastic Retainer and Ejection Lever  
For use with the 700-HN104 Sockets for 700-HC relays.  
Built-in ability to accept 1492 Snap-in Markers  
(1) See 700-HC Miniature Square Base Relay, Socket, and Retainer Clip Reference Chart.  
Description  
Pkg. Qty. Cat. No.  
Photo  
5
1492-MS5X12  
1492-MS6X9  
1492-MS6X12  
1492-MS8X9  
1492-MS8X12  
1492-MP-Blank  
5
Relay Identification Snap-in Markers  
Snap-in markers fit on top of product covers. Squares slip into molded slot on top of product  
cover.  
5
5
5
100  
Pre-Printed Identification Tags — contains 10 sheets of pre-printed and blank tags. Each  
sheet contains 13 sets of the markings CR…9CR, TR…9TR, M…9M, F, R, 1S, and 117 blank  
tags. Tags are peel-off with sticky backing for easy placement on relays.  
10  
50  
700-N40  
Markers — Used for terminal identification  
700-N41  
Socket and Retainer Clip Reference  
Relay Type  
Socket Cat. No.  
700-HN103  
Retainer Clip Cat. No.  
700-HN114  
700-HC  
700-HN128  
700-HN114  
700-HN104  
700-HN114 or 700-HN124  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
41  
Relay and Timer Specifications  
Specifications- 700-HC Relays  
Attribute  
700-HC  
Electrical Ratings  
Pilot Duty Rating (1)  
NEMA C300, R300  
7 A and 10 A  
Rated Thermal Current (I  
)
th  
Rated Insulation Voltage (U )  
250V IEC – 300V UL/CSA  
i
700-HC_4  
Hp  
700-HC22  
Hp  
Inductive  
Make  
Break  
Make  
Break  
120VAC  
15 A  
1.5 A  
1/8  
1/3  
15 A  
1.5 A  
1/3  
3/4  
Contacts  
240VAC  
7.5 A  
0.75 A  
7.5 A  
0.75 A  
General-purpose  
Resistive  
7 A, 277V AC  
7 A, 30V DC  
10 A, 277V AC  
10 A, 24V DC  
100 mW (10V, 10 mA) - Silver Contacts  
50 mW (5V, 10 mA, or 25V, 2 mA) - Gold Contacts  
Min. Low Energy Permissible Load  
Permissible Coil Voltage Variation  
80…110% of nom voltage at 50 Hz  
80…110% of nom voltage at 60 Hz  
80…110% of nom voltage at DC  
20% of nom voltage at AC  
10% of nom voltage at DC  
Must Dropout  
Voltage:  
Pickup:  
50 Hz  
2.2VA  
1.3VA  
60 Hz  
Inrush  
Sealed  
1.6VA  
1.1VA  
Coil  
Consumption  
10ꢀ  
AC Coils  
DC Coils  
1.0 W  
20% of VA (AC)  
10% of W (DC)  
Max. Allowable Leakage  
DesignSpecification/TestRequirements  
Electrical  
Pole-to-Pole  
2000V  
2000V  
Dielectric Withstand Voltage  
ElectricalLife (Cycles)  
Contact to Coil  
100,000 min  
Mechanical  
Degree of Protection (Open Type) IEC 529  
Mechanical lifecycles  
IP 20 (Guarded Terminal Sockets)  
6
6
20 x 10 (AC), 50 x 10 (DC)  
1800/HR  
Switching Frequency Operations  
Coil Voltages  
See Product Selection  
10 ms  
Pickup  
OperatingTime  
Dropout  
3 ms  
Maximum Operating Rate  
8 cycles/s  
Environmental  
Operating  
Storage  
–30…+55 °C (–22…+131 °F)  
–55…+85 °C (–67…+185 °F)  
2000 m (6560 ft)  
Temperature  
Altitude  
Insulating Material  
Enclosure  
Molded High Dielectric Material  
Transparent Dust Cover  
Contact Material  
Terminal Markings on Socket  
Sockets  
AgNi(700-HC2), AgNi + 5 μm All (700-HC1)  
In accordance with EN50 0005  
700-HN103, -HN128, -HN104  
cURus Recognized (File No. E14843, Guide NRNT2/NRNT8), cULus Listed when used with 700- HN103, -HN104, and -HN128 sockets  
(File No. E14843, Guide NRNT/NRNT7), CE Marked, LR Certified  
Certifications  
Standards  
UL 508, CSA 22.2 No. 14, EN 61810-1  
(1) See General Information on page 3.  
42  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Dimensions, 700-HC Relays  
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.  
37.2  
(1.46)  
36.7  
(1.44)  
5.6  
(0.22)  
6.1  
(0.24)  
27.7  
(1.09)  
20.7  
(0.82)  
20.7  
(0.82)  
27.7  
(1.09)  
700-HC Relay (Two-Pole)  
700-HC Relay (Four-Pole)  
27.0  
(1.06)  
60.9  
(2.40)  
21.5  
(0.85)  
76.0  
(2.99)  
35.6  
(1.40)  
3.2  
(0.13)  
18.9  
(0.74)  
34.9  
(1.37)  
32.0  
(1.26)  
35.5  
(1.40)  
2.5  
(0.10)  
Cat. No. 700-HN104  
2
2
2
Single Wire: 0.2 mm …2.5 mm (24 AWG…14 AWG), Double Wire: 0.2 …2.5 mm (24 AWG…14 AWG), Qty. 2 wires  
Wire Type: solid or stranded, copper only, Strip Length: 7 mm (9/32 in.), Torque: 0.5 N•m (4.4 lb•in)  
30.0  
24.9  
(57/64)  
21.1  
(1-3/16)  
Panel Mounting  
6.1 (15/64)  
(53/64)  
5
1
8
4
6
2
7
3
28.9  
(1-9/64)  
24.5  
(31/32)  
67.0  
(2-5/8)  
4.2  
(5/32)  
62.0  
(2-15/64)  
65.0  
(2-9/16)  
14  
12  
13  
9
11  
10  
#4-40  
M3  
30.0  
(1-11/64)  
26.0  
(1-1/64)  
Cat. No. 700-HN103  
Cat. No. 700-HN128  
2
2
2
Single Wire: 0.2 mm …2.5 mm (#24 AWG…14 AWG)  
Wire Size: 2 x 1.5 mm (#2-16 AWG…#1-20 AWG)  
(Either Solid or Stranded)  
2
Double Wire: 0.2…2 x 1.5 mm (24 AWG…16 AWG), Qty. 2 wires  
Wire Type: Solid or Stranded, Copper only  
Strip Length: 9 mm (3/8 in.) – Toque: 0.8 N•m (7 lb•in)  
Strip Length: 8 mm (5/16 in.), Torque: 0.5 N•m (4.4 lb•in)  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
43  
Relay and Timer Specifications  
700-HK Slim Line Relay  
8 A/16 A contact ratings  
DPDT/SPDT  
Plug-in blade-style terminals (2.5 x 0.5 mm)  
Retainer clip with sockets  
Options: LED, push-to-test and manual override, socket-mounted surge suppressor module, or  
timer module  
Standard ON/OFF flag indicator  
Relay faceplate accepts optional Bulletin1492 snap-in markers  
Choice of standard silver/nickel contacts or silver/nickel with gold plated contacts  
Maximum duty version available  
Wiring Diagrams  
Photo  
Description  
Contact Rating  
Coil Voltage  
Cat. No.(1)  
U.S./Canada  
International  
6V AC  
700-HK36A06  
700-HK36A12  
700-HK36A24  
700-HK36A1  
700-HK36A2  
700-HK36Z06  
700-HK36Z12  
700-HK36Z24  
700-HK36Z48  
12V AC  
24V AC  
120V AC  
240V AC  
6V DC  
SPDT  
1-Pole  
1 Form C  
AgNi Contacts  
16 A  
12V DC  
24V DC  
48V DC  
Input  
700-HN121, 700-HN221,  
700-HN223  
700-HN121, 700-HN221,  
700-HN223  
Socket  
110V DC  
700-HK36Z1  
6V AC  
700-HK32A06  
700-HK32A12  
700-HK32A24  
700-HK32A1  
700-HK32A2  
700-HK32Z06  
700-HK32Z12  
700-HK32Z24  
700-HK32Z48  
12V AC  
24V AC  
120V AC  
240V AC  
6V DC  
DPDT  
2-Pole  
2 Form C  
AgNi Contacts  
8 A  
12V DC  
24V DC  
48V DC  
Input  
700-HN122, 700-HN222,  
700-HN224  
700-HN122, 700-HN222,  
700-HN224  
Socket  
110V DC  
700-HK32Z1  
(1) Options  
Pilot Light: Add suffix (-4) to the selected 700-HK Relay catalog number except for the 240V AC units, add (-4L).  
Manual Operator and LED: Add suffix (-3-4) to the selected 700-HK Relay catalog number, except for the 240V AC units, add (-3-4L).  
AgNi Contact with Gold plating: Replace “3”with “X”om catalog number. For example, if catalog number 700-HK36A1 is required with gold plating, the new catalog number is 700-HKX6A1.  
For high inductive, Tungsten, or Capacitive load applications, replace the “3”with a “M”in the catalog number. Only available in a SPDT configuration and with 24V DC, 120V AC, or 240V AC coil voltages.  
44  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Accessories- 700-HK Relays  
Photo  
Description  
Pkg. Qty. Cat. No.  
Screw Terminal Socket — Panel or DIN Rail Mounting 5-blade miniature socket with 10 A rating for  
use with 1-pole, 700-HK relays. Accepts forked lug conductors. Socket includes a retainer clip.  
10  
700-HN121  
Screw Terminal Socket — Panel or DIN Rail Mounting 5-blade miniature socket with 16 A rating for  
use with 1-pole, 700-HK relays. Retainer clips are packaged separately with socket. Guarded terminal  
construction and compatible with optional plug-in module accessories.  
10  
10  
700-HN221  
700-HN223  
Spring Clamp Terminal Socket — Panel or DIN Rail Mounting  
5-blade miniature socket for use with 1-pole, 700-HK relays.  
Screw Terminal Socket — Panel or DIN Rail Mounting  
8-blade miniature socket with 5 A rating for use with 2-pole, 700-HK relays. Accepts forked lug  
conductors. This socket includes a retainer clip.  
10  
700-HN122  
Screw Terminal Socket — Panel or DIN Rail Mounting  
8-blade miniature socket with 8 A rating for use with 2-pole, 700-HK relays. Retainer clips are packaged  
separately with socket. Guarded terminal construction and compatible with optional plug-in module  
accessories.  
10  
10  
700-HN222  
700-HN224  
Spring Clamp Terminal Socket — Panel or DIN Rail Mounting  
8-blade miniature socket for use with 2-pole 700-HK relays.  
Flange Mount Adapter  
10  
10  
10  
700-HN226  
700-HN227  
700-HN229  
Used for panel-mounting bulletin 700-HK relays. Order must be for 10 adapters or multiples of 10.  
35 mm Rail Mount Adapter  
Mounts bulletin 700-HK relays to a 35 mm rail. Order must be for 10 adapters or multiples of 10.  
Socket Retainer Clip and Ejection Lever  
For use with 700-HN22, -HN222, -HN223, and -HN224 sockets. Orders must be for 10 clips or  
multiples of 10.  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
45  
Relay and Timer Specifications  
Specifications- 700-HK Relays  
Attribute  
700-HK  
Electrical Ratings  
Rated Thermal Current (I  
)
1-Pole, 1 CO, SPDT — 16 A  
2-Pole, 2 CO, DPDT — 8 A  
th  
Rated Insulation Voltage(Ui)  
250V IEC, 300V UL/CSA  
AC-15, 6.2 A  
AC-15, 2.9 A  
120VAC  
B300 Pilot Duty, 3 A A300 (700-HKM_)  
1/3 Hp (0.24 kW) 1-phase  
120VAC  
240VAC  
B300 Pilot Duty, 3.0 A 1/4 Hp (0.18 kW), 1-phase  
Inductive V AC  
AC-15, 3.1 A  
B300 Pilot Duty, 1.5 A A300(700-HKM_)  
3/4 Hp (0.55 kW), 1-phase  
AC-15, 1.4 A  
B300 Pilot Duty, 1.5 A 1/2 Hp (0.37 kW), 1-phase  
240VAC  
230VAC  
24VDC  
0.55 kW, 1-phase  
DC-13, 5.0 A  
230VAC  
24VDC  
0.37 kW, 1-phase  
DC-13, 3.0 A  
Contacts  
Inductive V DC  
Resistive  
125VDC  
250VDC  
230V AC  
277VAC  
DC-13, 0.2 A / R300 Pilot Duty, 0.22 A  
DC-13, 0.1 A / R300 Pilot Duty, 0.11 A  
AC-1, 16 A  
125VDC  
DC-13, 0.2 A / R300 Pilot Duty, 0.22 A  
DC-13, 0.1 A / R300 Pilot Duty, 0.11 A  
AC-1, 8 A  
5 A, 250V AC  
230V AC  
16 A, General Use  
277VAC  
8 A, General Use  
Make, Break , and  
Continuous  
30VDC  
DC-1, 12 A / 10 A, Resistive  
30VDC  
DC-1, 6 A / 6 A, Resistive  
300 mW (5V/60 mA or 60V/5 mA) for AgNi Contacts (700-HK3_)  
50 mW (5V/10 mA or 25V/2 mA) for AgNi + Gold Contacts (700-HKX_)  
Min. Permissible Contact Ratings  
500 mW (100V/5 mA or 5V/100 mA) for AgSnO Contacts (700-HKM_)  
2
Pickup:  
80…110% of Nominal Voltage at 50/60 Hz, 73...110% of Nominal Voltage at DC  
80% of Nominal V AC at 50/60 Hz, 40% of Nominal V DC  
Permissible Coil Voltage  
Variation  
holding Voltage:  
Must Dropout  
Voltage:  
20% of Nominal V AC at 50/60 Hz, 10% Nominal V DC  
Power Consumption  
Coil Voltages  
1.2V A (V AC Coils), 0.5 W (V DC Coils)  
See Overview/Product Selection  
Design Specification/Test Requirements  
Pole to Pole (VRMS)  
Contact to Coil  
(VRMS)  
Dielectric Withstand  
Voltage  
2000VAC  
4000VAC  
Mechanical  
Degree of Protection  
IP 20 (guarded terminal sockets), RT II — Flux-proof (Relay)  
6
Mechanical Life Operations  
10 x 10  
230V AC, 16 A Resistive: 100 000 min.  
230V AC, 8 A Resistive: 100 000 min.  
277V AC, 8 A Resistive: 30 000 min.  
30V DC, 6 A Resistive: 30 000 min.  
B300, R300, Hp (kW): 6000 min.  
277V AC, 16 A Resistive: 30 000 min.  
30V DC, 10 A Resistive: 30 000 min.  
B300, R300, Hp (kW): 6000 min.  
A300 (700-HKM_): 100,000 min.  
Electrical Lifecycles  
Mechanical: 18,000 cycles/hr.  
Electrical: 900 cycles/hr.  
Switching Frequency  
Pickup  
15 ms  
5 ms  
Operating Time at Nominal  
Voltage at 20 °C (ms)  
Dropout  
10…2000 Hz, 0.76 mm (0.03 in.) 2.5 G  
10…2000 Hz, 0.76 mm (0.03 in.) 5.0 G  
Operational  
Vibration  
Shock  
Non-Operational  
Operational  
Non-Operational  
15 G  
50 G  
Environmental  
Construction  
Operating  
Storage  
–40…+70 °C (–40…+158 °F)  
–40…+85 °C (–40…+185 °F)  
Temperature  
Altitude  
2000 m (6560 ft)  
Insulating Material  
Enclosure  
Molded High Dielectric Material  
Transparent Dust Cover  
Contact Material  
Terminal Markings on Socket  
700-HK3_: Silver nickel (AgNi); 700-HKX_: Silver Nickel + Gold Plating (AgNi + Au); 700-HKM_: Silver Tin Oxide(AgSnO )  
2
In accordance with EN 50005  
46  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Attribute  
Sockets  
700-HK  
1-Pole  
2-Pole  
700-HN122 (2 x 5 A @ 70 °C)  
700-HN222 (2 x 8 A @ 70 °C)  
700-HN121 (10 A @ 70 °C)  
700-HN221 (16 A @ 50 °C, 12 A @ 70 °C)  
Screw Terminal  
Spring Clamp  
700-HN223 (15 A @ 40 °C with 2 conductors per terminal)  
(10 A @ 70 °C with 1 conductor per terminal)  
700-HN224 (2 x 8 A@ 70 °C)  
Approvals  
CSA Certified, File 75088, UL Recognized, File E3125  
Guide NLDX2/NLCX8, cULus Listed with Allen-Bradley sockets (File No. 3125 Guide NLDX/NLDX7), CE Marked  
EN61810-1, CSA 22.2 No. 14, UL 508  
Certifications  
Standards  
Dimensions- 700-HK Relays  
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.  
12.4  
(1/2)  
29.0  
(1-9/64)  
12.4  
(1/2)  
29.0  
(1-9/64)  
32.8  
(1-19/64)  
30.1  
(1-3/16)  
32.8  
(1-19/64)  
30.1  
(1-3/16)  
6.5  
(1/4)  
6.5  
(1/4)  
2.5  
(3/32)  
0.5  
(1/32)  
4.75  
0.5  
(1/32)  
COM 11  
NC 12  
2
(3/16)  
3
NO 14  
4
A1  
8
A1  
5
COM 11  
4
A2  
1
NO 24  
5
NC 22  
7
A2  
1
COM 21  
6
NC 12  
2
NO 14  
3
Cat. No. 700-HK36_ (SPDT)  
Cat. No. 700-HK32_ (DPDT)  
COM 11 NO 14NC 12  
A1  
8
COM 11 NO 14 NC 12  
A1  
8
3
4
2
3
4
2
15.8  
(5/8)  
15.8  
(5/8)  
COM 21 NO 24 NC 22  
A2  
1
COM 21 NO 24NC 22  
A2  
1
6
5
7
6
5
7
Cat. No. 700-HN222  
Cat. No. 700-HN224  
COM 11 NO 14 NC 12  
A1  
5
COM 11 NO 14 NC 12  
A1  
5
4
3
2
4
3
2
15.8  
(5/8)  
15.8  
(5/8)  
A2  
1
A2  
1
Cat. No. 700-HN221  
Cat. No. 700-HN223  
64.9  
(2-9/16)  
44.7  
(1-3/4)  
32.5  
(1-9/32)  
35.3  
(1-25/64)  
22.6  
(57/64)  
34.7  
(1-3/8)  
35.4  
(1-13/32)  
95.6  
(3-49/64)  
82.85  
(3-17/64)  
Cat. No. 700-HN223, 700-HN224  
Wire Size: 0.2 mm ...1.5 mm (#24 AWG....#14 AWG)  
Either Solid or Stranded  
Cat. No. 700-HN221, 700-HN222  
Wire Size: 0.2 mm ...2.5 mm (#24 AWG....#12 AWG)  
Either Solid or Stranded  
2
2
2
2
Strip Length: 8 mm (5/16 in)  
Strip Length: 8 mm (5/16 in), Torque: 0.8Nm (7.0 lb.-in.)  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
47  
Relay and Timer Specifications  
Dimensions - 700-HK Relays  
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.  
46.0  
(1-13/16)  
14.4  
(37/64)  
3.6  
(9/64)  
14.4  
(37/64)  
38.0  
(1-1/2)  
46.9  
(1-27/32)  
42.4  
(1-43/64)  
36.6  
(1-11/16)  
39.8  
(1-37/64)  
18.1  
(23/32)  
2.0  
(5/64)  
34.8  
(1-3/8)  
Cat. No. 700-HN227  
Cat. No. 700-HN226  
1.0  
(0.04)  
12.5  
(1/2)  
6.2  
(15/64)  
50  
(1-63/64)  
27.0  
(1.06)  
35.0  
(1.38)  
5.2  
(13/64)  
7.5  
(0.30)  
1000  
(39-3/8)  
Cat. No. 199-DR4 DIN Mounting Rail Series B Has No Mounting Holes  
Cat. No. 199-DR1 DIN Mounting Rail Series B  
Cat. No.  
199-DR1  
A
B
C
D
Approx. Shipping Wt.  
1.85 kg  
(4.07lb)  
(10/pkg)  
35  
(1-3/8)  
27  
(1-1/16)  
7.5  
(19/64)  
1.02  
(1/64)  
3.68 kg  
(8 lb)  
(5/pkg)  
35  
(1-3/8)  
27  
(1-1/16)  
15  
(19/32)  
2.3  
(3/32)  
199-DR4  
48  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
7.11  
(9/32)  
2.03  
(5/64)  
21  
6
11  
3
2.03  
(5/64)  
7.11  
(9/32)  
Five M3.5  
x 0.315 Screws  
11  
4
22  
7
24  
Eight  
M3.5 x 0.315  
Screws  
4.06  
(5/32)  
14  
3
4.06  
(5/32)  
12  
2
5
12  
2
(1)  
14  
3.0 Ø  
39.5  
(1-17/32)  
35.5  
(1-13/32)  
39.5  
(1-17/32)  
4
(1/8)  
84.1  
(3-5/16)  
84.1  
(1)  
Use M3 Screws  
3.0 Ø  
(1/8)  
(3-5/16)  
35.5  
(1-13/32)  
5 (+)  
(A1)  
Use M3 Screws  
8 (+)  
(A1)  
1 (-)  
(A2)  
4.06  
(5/32)  
4.06  
(5/32)  
1 (-)  
(A2)  
29.9  
(1-3/16)  
15.6  
(5/8)  
29.9  
(1-3/16)  
15.6  
(5/8)  
54.1  
(2-1/8)  
54.1  
(2-1/8)  
Cat. No. 700-HN121  
Cat. No. 700-HN122  
2
2
Wire Size: 2 x 2.5 mm  
Single Wire – Up to #14 AWG  
Wire Size: 2 x 2.5 mm  
Single Wire – Up to #14 AWG  
2
2
Double Wire – 2 x 2.5 mm (14 AWG… 20 AWG) Qty. 2 wires  
(Either Solid or Stranded)  
Double Wire – 2 x 2.5 mm (14 AWG… 20 AWG) Qty. 2 wires  
(Either Solid or Stranded)  
Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)  
Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
49  
Relay and Timer Specifications  
700-HL Terminal Block Relay  
Relay and socket assembled interface modules for high density interposing or isolation  
applications  
Screw terminal and spring-clamp bases  
6 A relay, choice of silver or gold contacts  
2 A solid-state relay — DC output  
2 A solid-state relay — AC output  
SPDT (relay), 1 N.O. (solid-state)  
Built-in retainer clip and snap-in marker lever  
Standard LED, reverse polarity protection, and surge protection  
Externally replaceable relay modules  
Unique leakage current suppression version to address industry concerns of nuisance coil turn-on or contact non-drop out when connecting  
to PLCs with leakage current  
Available with hazardous location certification  
Standard built-in Features:  
LED  
Reverse Polarity Protection  
for DC Inputs  
Coil Surge Protection(1)  
Cat. No. 700-HLT1Z24  
Cat. No. 700-HLT2Z24  
Cat. No. 700-HLS1Z24  
Cat. No. 700-HLS11Z24  
(3)  
Specifications  
Output Type  
SPDT (1 C/O); Ith =6A(2)  
1 N.O. solid-state; Ith = 2 A, 24V DC or Ith =2 A, 240V AC  
Recommended Tightening  
Torque  
0.5 N• m max. (4.4 lb• in)  
Wire Range  
Screw Terminal: 0.14 mm2…2.5 mm2 (#26…#14 AWG), Spring Terminal: 0.2 mm2…2.5 mm2 (#24…#14 AWG)  
UL, cULus, cURus, ABS, CE  
Approvals  
(1) Diode surge protection provided.  
(2) For Gold-plated contacts: Add the letter “X”at the end of the catalog number. For example: if Cat. No. 700-HLT1Z24 is required with gold plating, the new cat. no. is 700-HLT1Z24X.  
(3) Reverse polarity on the output terminals of the solid-state relay will result in the output being "ON" regardless of the state of the input voltage.  
Cat. No.  
(Spring Clamp  
Terminals)  
Cat. No.  
(Spring Clamp  
Terminals)  
Cat. No.  
Pkg. Quantity (Screw Terminals)  
(DC Output)  
Cat. No.  
(Screw Terminals)  
(AC Output)  
Pkg.  
Qty.  
Cat. No.  
(Screw Terminals)  
Input Voltage  
(DC Output)  
(2)  
12V DC  
10  
10  
10  
10  
10  
10  
10  
10  
10  
700-HLT1Z12 700-HLT2Z12  
700-HLT1Z24 700-HLT2Z24  
700-HLT1Z48 700-HLT2Z48  
10  
(2)  
(2)  
(2)  
24V DC  
700-HLS1Z24  
700-HLS1Z48  
700-HLS2Z24  
700-HLS2Z48  
700-HLS11Z24  
700-HLS11Z48  
(2)  
48V DC  
10  
12V AC/DC  
24V AC/DC  
48V AC/DC  
110/125V AC/DC  
220…240V AC/DC  
240V AC  
700-HLT1U12  
700-HLT1U24  
700-HLT1U48  
700-HLT1U1  
700-HLT1U2  
700-HLT1A2  
700-HLT2U12  
700-HLT2U24  
700-HLT2U48  
700-HLT2U1  
700-HLT2U2  
10  
(2)  
700-HLS1U1  
700-HLS1U2  
700-HLS2U1  
700-HLS2U2  
700-HLS11U1  
700-HLS11U2  
(2)  
10  
50  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Cat. No.  
Cat. No.  
(Spring Clamp  
Terminals)  
Cat. No.  
Pkg. Quantity (Screw Terminals)  
(DC Output)  
Cat. No.  
(Screw Terminals)  
(AC Output)  
Pkg.  
Qty.  
Cat. No.  
(Screw Terminals)  
(Spring Clamp  
Terminals)  
(DC Output)  
Input Voltage  
Built-in LCSC (leakage  
current suppression  
circuit)  
(2)  
(2)  
10  
10  
700-HLT1L1  
10  
10  
700-HLS1L1  
700-HLS1L2  
700-HLS11L1  
700-HLS11L2  
120V AC and 125V DC(1)  
Built-in LCSC (leakage  
current suppression  
circuit) 240V AC (1)  
(2)  
(2)  
700-HLT1L2  
Hazardous Location  
Certification 24V DC  
10  
10  
700-HLT1Z24-EX  
700-HLT1Z12-EX  
10  
10  
700-HLS1Z24-EX  
Hazardous Location  
Certification 12V DC  
Hazardous Location  
Certification 110/125V 10  
AC/DC  
700-HLT1U1-EX  
10  
700-HLS1U1-EX  
(1) Leakage current suppression up to 2.2 mA off state current.  
(2) Electromechanical relay to solid-state relay interchangeability is possible.  
Accessories  
-
700-HLT, -HLS Relays  
Description  
Pkg.  
Quantity  
Photo  
Socket Input Voltage  
Cat. No.  
12V AC/DC  
24V AC/DC  
48V AC/DC  
700-TBR12  
700-TBR24  
700-TBR48  
Replacement Relays(1)  
20  
20  
Order must be for 20 relays or multiples of 20.  
110/125V AC/DC  
220…240V AC/DC  
700-TBR60  
24V DC  
700-TBS24  
700-TBS60  
Replacement SSR  
4-blade miniature relay for use with 1 N.O. SSR DC output.  
Order multiples of 20.  
48V DC, 110/125V AC/DC  
220…240V AC/DC  
Replacement SSR  
4-blade miniature relay for use with 1 N.O. SSR AC output.  
Order multiples of 20.  
20  
20  
24V DC  
700-TBS124  
700-TBS160  
Replacement SSR  
4-blade miniature relay for use with 1 N.O. SSR AC output.  
Order must be for 20 relays or multiples of 20.  
48V DC  
110/125V AC/DC  
220…240V AC/DC  
Color  
Red  
700-TBJ20R  
700-TBJ20G  
20-Way Jumper Can be cut to required length.  
Ith =36 A max per 20-way jumper.  
1
Grey  
Blue  
700-TBJ20B  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
51  
Relay and Timer Specifications  
Pkg.  
Quantity  
Photo  
Description  
Socket Input Voltage  
Cat. No.  
End Barrier  
Used for visual inspection of groups, safe separation of  
neighboring 700-HL modules that end with jumpers.  
10  
Black  
700-HN177  
Snap-in Marker  
These snap-in markers have a 6 x 10 mm surface and snap into  
the ejection lever for the relay. For custom markers, contact your local  
Rockwell Automation sales office or Allen-Bradley distributor for more  
information.  
100  
Blank  
1492-MC6X10  
(1) For gold-plated contacts: Add the letter “X”at the end of the catalog number. For example: if Cat. No. 700-TBR24 is required with gold plating, the new cat. no. is 700-TBR24X.  
Dimensions - 700-HL Relays  
700-HL Spring Terminal Design Single Wire: 0.2 mm2…2.5 mm2 (#24 AWG…#14 AWG ) Wire Type: Solid or stranded, copper only.Strip Length: 9 mm (11/32 in.)  
Cat. No. 199-DR1 DIN Mounting Rail Series B, Cat. No. 199-DR4 DIN Mounting Rail Series B has no mounting holes.  
Specifications - 700-HLT Relays  
Cat. No. 700-HLT… (Relay Output)  
Electrical Ratings  
Pilot Duty Rating  
B 300, R 300  
1-Pole — 6 A  
250V IEC, 300V UL/CSA  
1-Pole  
Rated Thermal Current (I  
)
th  
Rated Insulation Voltage(Ui)  
24VAC, 1-phase  
120VAC, 1-phase  
240VAC, 1-phase  
30 A  
30 A  
15 A  
5 A  
3 A  
Inductive V AC  
Inductive V DC  
Break  
Make  
1.5 A  
24VDC  
125VDC  
240VDC  
24VDC  
DC-13, 1.0 A  
DC-13, 0.2 A  
DC-13, 0.1 A  
6.0 A  
Contacts  
Resistive  
Make, Break, and  
Continuous  
250VAC  
240VDC  
6.0 A  
0.1 A  
AC-15 250V, 3 A N.O. Contact, 1.5 A N.C. Contact  
Inductive Load  
DC-13 24V, 1 A N.O., and N.C. Contact  
52  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Cat. No. 700-HLT… (Relay Output)  
12V, 6 mA (72 mW) for Silver Contacts,  
Min. Permissible Contact Ratings  
Permissible Coil Voltage Variation  
Power Consumption 10%  
8V, 2.5 mA (20 mW) for Gold Contacts  
85…110% of Nominal Voltage at 50 Hz  
85…110% of Nominal Voltage at 60 Hz  
80…110% of Nominal Voltage at DC  
Must Dropout  
Voltage:  
10% of Nominal Voltage at AC  
5% of Nominal Voltage at DC  
Pickup:  
AC  
DC  
0.3VA  
0.2 W  
Design Specification / Test Requirements  
Pole to Pole  
(VRMS)  
1000V  
4000V  
Dielectric Withstand Voltage  
Contact to Coil  
(VRMS)  
Input Voltage  
12V AC/DC  
1K  
24V AC/DC  
2 K  
48V AC/DC  
6 K  
120V AC/DC  
26 K  
240V AC/DC  
56 K  
120VLCSC  
16 K  
240VLCSC  
35 K  
Impedance(Ohms)  
Mechanical  
Degree of Protection  
IP20  
7
Mechanical Life Operations  
1 x 10  
6 A Resistive: 100 000 min.  
Electrical Life Operations  
24V DC, 1 A Inductive: 200 000 min.  
120V AC 1 A Inductive: 300 000 min.  
Switching Frequency Operations (no-load)  
Coil Voltages  
10 cycles/sec  
See Overview/Product Selection  
Pickup  
7 ms  
3 ms  
Operating Time at Nominal Voltage at 20 °C (ms)  
Dropout  
Maximum Operating Rate (full load = 6 A)  
Coil Surge Protection  
6 cycles/min.  
Per EN 61000-4.5; Surge Immunity (801-5)  
Class III: 2 kV common and 1 kV differential mode  
Environmental  
Operating  
Storage  
–40…+55 °C  
–40…+100°C  
Temperature  
Altitude  
2000 m (6560 ft)  
Construction  
Insulating Material  
Enclosure  
Molded High Dielectric Material  
RelayIP67  
Contact Material  
Terminal Markings on Socket  
Silver Tin Ox, AgSnO or Silver with Gold Plating, AgSnO + Au  
2
2
In accordance with EN50 0005  
cULus Listed (File No. E3125, E14843 Guide NLDX/NLDX7) with Allen-Bradley socket, CE Marked, ABS  
(American Bureau of Shipping)  
Certifications  
Standards  
EN 61810-1, CSA 22.2,UL 508,NEMA IEE MAC Compliant, ICS-2 Compliant  
Class 1, Zn 2, Groups IIC, Ex nC IIC T5 Ta< 55 °C  
700-HLT1Z12-EX(12V DC supply)  
700-HLT1Z24-EX, 700-HLS1Z24-EX (24V DC supply)  
700-HLT1U1-EX, 700-HLS1U1-EX (110V/125V AC/DC supply)  
UL Listed  
(UL60079-15)  
Hazardous Location Approvals  
CSA Certified (1)  
(CAN/CSA  
E60079-15)  
700-HLT1Z12-EX(12V DC supply)  
700-HLT1Z24-EX, 700-HLS1Z24-EX (24V DC supply)  
(1) Product shall be installed in an enclosure providing at least IP54 protection. Provisions shall be made to prevent the rated voltage from being exceeded by transient disturbances of more than 40%.  
Cat. No. 700-HLS… (Solid-state Output)  
Electrical  
Rated Thermal Current (I  
)
2 A (DC output)  
2 A (AC output)  
th  
Rated Insulation Voltage(Ui)  
250V IEC, 300V UL/CSA  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
53  
Relay and Timer Specifications  
Cat. No. 700-HLS… (Solid-state Output)  
Min. Control Voltage  
80% nominal voltage  
110% nominal voltage  
Maximum Control Voltage  
Control Current  
9 mA 10% (24V) 4 mA 10% (120/240V)  
0.4 x nominal voltage (24V), 0.35 x nominal voltage (120/240V)  
Control Circuit  
Release Voltage  
3200 ohms (24V),  
16k ohms (120V),  
32k ohms (240V)  
2500 ohms (24V),  
12k ohms (120V),  
24kohms(240V)  
Min. Control Circuit Resistance  
Load Voltage Range  
0…24VDC  
33V  
24…240VAC  
600V  
Max. Repetitive Blocking Voltage  
Max. Switching Current (inductive/  
resistive)  
2 A DC  
1 A AC  
Outputs  
On State Voltage Drop @ Max.  
Switching Current  
<120 mV DC  
<1VAC  
Leakage Current  
max.100μA(@U=24V)  
AC  
DC  
0.6VA(120V),1VA(240V)  
Power Consumption 10%  
Dielectric Withstand Voltage  
0.2 W  
Design Specification/TestRequirements  
0.3 W  
Pole to Pole (VRMS)  
Contact to Coil (VRMS)  
24VDC  
2500V  
2500V  
Input Voltage  
48VDC  
9 K  
120V AC/DC  
240V AC/DC  
58 K  
120VLCSC  
16 K  
240VLCSC  
35 K  
Impedance(Ohms)  
2K  
26 K  
Mechanical  
Degree of Protection  
Input Voltages  
IP20  
See Overview/Product Selection  
Turn on Time  
30 μs (DC only input voltage), 7 ms (AC/DC input voltage)  
350 μs (DC only input voltage), 10 ms (AC/DC input voltage)  
300 Hz  
Operating Time at Nominal Voltage at  
20 °C (ms)  
Drop Out Time  
Maximum Operating Rate  
Environmental  
Construction  
Operating  
Storage  
–20…+55 °C  
–40…+70 °C  
Temperature  
Altitude  
2000 m (6560 ft)  
Insulating Material  
Enclosure  
Molded High-Dielectric Material  
RelayIP67  
Terminal Markings on Socket  
Certifications  
In accordance with EN50 0005  
cULus Listed (File No. E14843, Guide NLDX/NLDX7), CE Marked, ABS (American Bureau of Shipping)  
UL 508, CSA C22.2 No. 14, EN 61810-1  
Standards  
Class 1, Zn 2, Groups IIC, Ex nC IIC T5 Ta < 55 °C  
700-HLT1Z24-EX, 700-HLS1Z24-EX (24V DC supply)  
700-HLT1U1-EX, 700-HLS1U1-EX (110V/125V AC/DC supply)  
UL Listed  
(UL60079-15)  
Hazardous Location Approvals  
CSA Certified (1)  
(CAN/CSA60079-15)  
700-HLT1Z24-EX, 700-HLS1Z24-EX (24V DC supply)  
(1) Product shall be installed in an enclosure providing at least IP54 protection. Provisions shall be made to prevent the rated voltage from being exceeded by transient disturbances of more than 40%.  
54  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Dimensions - 700-HLT, -HLS Relays  
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.  
76.0  
(2.99)  
76.0  
(2.99)  
93.0  
(3.66)  
88.0  
(3.46)  
6.2  
(0.24)  
6.2  
(0.24)  
700-HLT / -HLS Screw Terminal Design  
700-HLT / -HLS Spring Terminal Design  
2
2
2
2
Single Wire: 0.14 mm …2.5 mm (#26 AWG…#14 AWG)  
Single Wire: 0.2 mm …2.5 mm (#24 AWG…#14 AWG)  
Wire Type: Solid or stranded, copper only  
Strip Length: 9 mm (11/32 in.)  
2
2
Double Wire: 2 x 0.14 mm …2 x 1.5 mm (2 x #26 AWG…2 x #16 AWG)  
Wire Type: Solid or stranded, copper only  
Strip Length: 9 mm (11/32 in). Torque: 0.5 N•m (4.4 lb•in)  
Dimensions - 700-HLT, -HLS Relay Accessories  
12.5  
(1/2)  
1.0  
(0.04)  
6.2  
(15/64)  
50  
(1-63/64)  
5.2  
(13/64)  
35.0  
27.0  
(1.38)  
(1.06)  
7.5  
1000  
(0.3)  
(39-3/8)  
Cat. No. 199-DR1 DIN Mounting Rail Series B  
Cat. No. 199-DR4 DIN Mounting Rail Series B Has No Mounting Holes  
Cat. No.  
199-DR1  
199-DR4  
A
B
C
D
Approx. Shipping Wt.  
1.85 kg (4.07lb)  
3.68 kg (8 lb)  
Pkg. Qty.  
10/pkg  
5/pkg  
35 (1-3/8)  
35 (1-3/8)  
27 (1-1/16)  
27 (1-1/16)  
7.5 (19/64)  
15 (19/32)  
1.02 (1/64)  
2.3 (3/32)  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
55  
Relay and Timer Specifications  
700-HL 2-pole Terminal Block Relay  
Relay and socket assembled interface modules for high density interposing or isolation applications  
Screw terminal and spring-clamp bases  
10 A relay, choice of silver or gold contacts  
DPDT (relay)  
Built-in retainer clip and snap-in marker lever  
Standard LED, reverse polarity protection, and surge protection  
Externally replaceable relay modules  
Output Type  
DPDT (2 C/O); Ith = 10 A  
Recommended Tightening Torque  
Wire Range  
0.6 N•m max. (5.3 lb•in.)  
Screw Terminal: 0.2…2.5 mm2 (#24…14 AWG), Spring Terminal: 0.2…2.5 mm2 (#24…14 AWG)  
Approvals  
cULus, cURus, CE  
Input Voltages  
12V DC  
Pkg. Quantity  
Cat. No.(1) (Screw Terminals)  
700-HLT12Z12  
Cat. No.(Spring Clamp Terminals)  
700-HLT22Z12  
10  
10  
10  
10  
10  
10  
24V DC  
700-HLT12Z24  
700-HLT22Z24  
48V DC  
700-HLT12Z48  
700-HLT22Z48  
24V AC/DC  
700-HLT12U24  
700-HLT22U24  
110/125V AC/DC  
220…240V AC/DC  
700-HLT12U1  
700-HLT22U1  
700-HLT12U2  
700-HLT22U2  
(1) For Gold-plated contacts: Add the letter "X" at the end of the catalog number. Example: Cat. No. 700-HLT12Z24 with gold plated contacts is Cat. No. 700-HLT12Z24X. The following relays are available with the gold-plated contact  
option: 700-HLT_2Z24, 700-HLT_2U24, 700-HLT_2U1, and 700-HLT_2U2. Not available on 12V and 48V DC products.  
Accessories - 700-HL Relays (2- pole)  
Pkg.  
Qty.  
Photo  
Description  
Socket Input Voltage/Color  
Cat. No.  
12V DC  
700-TBR212  
700-TBR224  
700-TBR248  
700-TBR2110  
700-TBJ08R  
700-TBJ08G  
700-TBJ08B  
Replacement Relays  
Order must be for 20 relays or multiples 20  
of 20.  
24V AC/DC  
48V DC  
110/125V AC/DC, 220…240V AC/DC  
Red  
8-Way Jumper  
Can be cut to required length. Ith  
=
1
Grey  
Blue  
10 A max per 8-way jumper.  
End Barrier  
Used for visual inspection of groups,  
safe separation of neighboring 700-HL  
modules that end with jumpers.  
10  
Black  
Blank  
700-HN177  
Snap-in Marker(1)  
These snap-in markers have a 6 x 12  
mm surface and snap into the ejection  
lever for the relay.  
100  
1492-MS6X12  
(1) For custom markers, contact your local Rockwell Automation sales office or Allen-Bradley distributor for more information.  
56  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Specifications - 700-HL Relays (2-Pole)  
Cat. No. 700-HLT…2-Pole (Relay Output)  
Electrical Ratings  
Pilot Duty Rating  
B 300, R 300  
2-Pole — 10 A  
Rated Thermal Current (I  
)
th  
Rated Insulation Voltage(Ui)  
250V IEC, 300V UL/CSA  
120VAC  
240VAC  
AC-15, 3.0A B 300, 3.0 A  
1/4 HP (186 W), 1-phase  
1/2 HP (373 W), 1-phase  
Inductive V AC  
UL  
AC-15, 3.0 A  
B 300, 1.5 A  
24VDC  
125VDC  
250VDC  
250VAC  
24VDC  
DC-13, 2.0 A  
DC-13, 0.3 A  
DC-13, 0.2 A  
10 A  
Contacts  
Inductive V DC  
Resistive Make,  
Break  
,
and  
10 A  
Continuous  
250VDC  
0.28 A  
Min. Permissible Contact Ratings  
Permissible Coil Voltage Variation  
12V, 10 mA (120 mW) for Silver Contacts, 5V, 1 mA (50 mW) for Gold Contacts  
Nominal  
10% of  
85…110% of Nominal Voltage at 50 Hz  
85…110% of Nominal Voltage at 60 Hz  
80…110% of Nominal Voltage at DC  
Voltage at AC  
Must Dropout  
Voltage:  
Pickup:  
5% of Nominal  
Voltage at DC  
DesignSpecification/TestRequirements  
Pole to Pole  
(VRMS)  
1000V  
5000V  
Contact to Coil  
(VRMS)  
Dielectric Withstand Voltage  
Input Voltage  
Adjacent  
Contacts  
(VRMS)  
2500V  
12V AC/DC  
1 K  
24V AC/DC  
2 K  
48VDC  
3 K  
120V AC/DC  
34 K  
240V AC/DC  
72 K  
0.8VA  
0.7 W  
Impedance(Ohms)  
AC  
DC  
N/A  
0.5VA  
0.5 W  
N/A  
0.4VA  
Power Consumption 10%  
0.4 W  
0.8 W  
0.5 W  
Mechanical  
Degree of Protection  
IP20  
7
Mechanical Life Operations  
3 x 10  
250V AC/24V DC, 8 A Resistive: 100 000 min.  
24V DC, 10 A Resistive: 6000 min.  
Electrical Life Operations  
250V DC, 0.28 A Resistive: 6000 min.  
250V AC, 10 A Resistive: 30 000 min.  
Switching Frequency Operations (no-load)  
Coil Voltages  
1200 cycles/sec  
See Overview/Product Selection  
typical 10 ms  
Pickup  
Operating Time at Nominal Voltage at 20 °C (ms)  
Maximum Operating Rate (full load = 6 A)  
Dropout  
typical 10 ms  
6 cycles/min.  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
57  
Relay and Timer Specifications  
Cat. No. 700-HLT…2-Pole (Relay Output)  
Environmental  
Operating  
–40…+60 °C  
–40…+100 °C  
Temperature  
Altitude  
Storage  
2000 m (6560 ft)  
Construction  
Insulating Material  
Enclosure  
Molded High-Dielectric Material  
Relay RT II — flux-proof, pollution degree 2 installation environment  
AgNi 90/10 or AgNi 90/10 + Au  
Contact Material  
Terminal Markings on Socket  
Certifications  
In accordance with EN50 0005  
cULus Listed (File No. E3125, Guide NRNT/NRNT7), CE Marked  
UL 508, CSA C22.2 No. 14, EN 61810-1  
Standards  
Dimensions - 700-HL (2-pole)  
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.  
92.8  
(3.65)  
87.7  
(3.45)  
14  
(0.55)  
14  
(0.55)  
75  
(2.95)  
75  
(2.95)  
Bulletin 700-HL Screw Terminal Design  
Single Wire: 0.14 mm …2.5 mm (#26 AWG…14 AWG)  
Bulletin 700-HL Spring Terminal Design  
2
2
2
2
Single Wire: 0.2 mm …2.5 mm (#24 AWG…#14 AWG)  
Wire Type: Solid or stranded, copper only  
Strip Length: 9 mm (11/32 in)  
2
2
Double Wire: 2 x 0.14 mm …2 x 1.5 mm (2 x #26 AWG…2 x 16 AWG)  
Wire Type: Solid or stranded, copper only  
Strip Length: 9 mm (11/32 in). Torque: 0.5 N•m (4.4 lb•in)  
97.8  
(3.85)  
Bulletin 700-TBJ08_ 8-Way Jumper  
58  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
12.5  
(1/2)  
1.0  
(0.04)  
6.2  
(15/64)  
50  
(1-63/64)  
5.2  
(13/64)  
35.0  
27.0  
(1.38)  
(1.06)  
7.5  
1000  
(0.3)  
(39-3/8)  
Cat. No. 199-DR1 DIN Mounting Rail Series B  
Cat. No. 199-DR4 DIN Mounting Rail Series B Has No Mounting Holes  
Cat. No.  
199-DR1  
A
B
C
D
Approx. Shipping Wt.  
1.85 kg  
(4.07lb)  
(10/pkg)  
35  
(1-3/8)  
27  
(1-1/16)  
7.5  
(19/64)  
1.02  
(1/64)  
3.68 kg  
(8 lb)  
(5/pkg)  
35  
(1-3/8)  
27  
(1-1/16)  
15  
(19/32)  
2.3  
(3/32)  
199-DR4  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
59  
Relay and Timer Specifications  
700-HLF Terminal Block Timing Relay  
Relay and socket assembled modules for high-density applications  
Screw terminal bases  
6 A relay, choice of silver or gold contacts  
SPDT (relay)  
Four timing functions  
Time range from 0.1 sec...6 hr  
Built-in retainer clip and snap-in marker lever  
Standard LED, reverse polarity protection, and surge protection  
Externally replaceable relay modules  
A2  
A1  
Wiring Diagram  
18  
15  
16  
Output Type  
SPDT (1 C/O); Ith = 6A§  
Recommended Tightening Torque  
Wire Range  
0.5 N•m max. (4.4 lb•in)  
Screw Terminal: 0.14 mm2…2.5 mm2 (#26…#14 AWG)  
Approvals  
cULus, cURus, CE  
Assembled Device  
Input Voltage  
Pkg. Quantity  
Cat. No.(1)  
24V AC/DC  
10  
700-HLF1U24  
(1) For gold-plated contacts add an X after the catalog number listed.  
Accessories - 700-HLF Relays  
Terminal block timing relay bases are not sold separately.  
Socket Input  
Voltage  
Photo  
Description  
Pkg. Quantity  
Cat. No.  
Replacement Relays  
Order must be for 20 relays or multiples of 20.  
20  
24V AC/DC  
700-TBR24(1)  
Color  
Red  
20-Way Jumper  
700-TBJ20R  
700-TBJ20G  
700-TBJ20B  
Can be cut to required length. Ith = 36 A max per 20-way  
1
Grey  
Blue  
jumper.  
End Barrier  
Used for visual inspection of groups, safe separation of  
neighboring 700-HL modules that end with jumpers.  
10  
Black  
Blank  
700-HN177  
Snap-in Marker  
These snap-in markers have a 6 x 10 mm surface and snap into 100  
the ejection lever for the relay.  
1492-MC6X10  
(1) For gold-plated contacts: Add the letter “X”at the end of the catalog number. For example: if Cat. No. 700-TBR24 is required with gold plating, the new cat. no. is 700-TBR24X.  
60  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Function and Connection Diagrams - 700-HLF Relays  
15  
A1  
U (A1/A2)  
1 c/o (SPST)  
t
R
LED  
A2  
A1  
18 16  
15  
On-Delay  
U (A1/A2)  
1 c/o (SPST)  
t
R
LED  
A2  
A1  
18 16  
One Shot  
15  
U (A1/A2)  
1 c/o (SPST)  
t
R
0.5s  
LED  
A2  
A1  
18 16  
15  
Pulse  
U (A1/A2)  
1 c/o (SPST)  
t
t
t
R
LED  
A2  
18 16  
Flasher  
Specifications- 700-HLF Relays  
Cat. No. 700-HLF… (Relay Output) (1)  
Electrical Ratings  
Pilot Duty Rating  
B 300, R 300  
Rated Thermal Current (I  
)
1-Pole — 6 A  
th  
Rated Insulation Voltage(Ui)  
250V IEC, 300V UL/CSA  
1-Pole  
Inductive  
24VAC, 1-phase  
30 A  
30 A  
5 A  
3 A  
120VAC, 1-  
phase  
Contacts  
240VAC, 1-  
phase  
15 A  
1.5 A  
24VDC  
120VDC  
240VDC  
1.0 A  
0.2 A  
0.1 A  
Make, Break and  
Continuous VDC  
AC-15 250V, 3 A N.O. Contact, 1.5 A N.C. Contact  
Inductive Load  
DC-13 24V, 1 A N.O. and N.C. Contact  
Min. Permissible Contact Ratings  
12V, 6 mA (72 mW) for Silver Contacts, 8V, 2.5 mA (20 mW) for Gold Contacts  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
61  
Relay and Timer Specifications  
10% of Nominal  
Voltage at AC,  
5% of Nominal  
Voltage at DC  
85…110% of Nominal Voltage at 50 Hz  
85…110% of Nominal Voltage at 60 Hz  
80…110% of Nominal Voltage at DC  
Must Dropout  
Voltage:  
Permissible Coil Voltage Variation  
Power Consumption 10ꢀ  
Pickup:  
AC/DC  
0.5VA  
Design Specification/TestRequirements  
Pole to Pole  
(VRMS)  
1000V  
4000V  
Dielectric Withstand Voltage  
Contact to Coil  
(VRMS)  
Input Voltage  
24V AC/DC  
2 K  
Impedance(Ohms)  
Mechanical  
Degree of Protection  
IP20  
7
Mechanical Life Operations  
1 x 10  
6 A Resistive: 100,000 min.  
24V DC, 1 A Inductive: 200,000 min.  
120V AC 1 A Inductive: 300,000 min.  
Electrical Life Operations  
Switching Frequency Operations (no-load)  
Coil Voltages  
10 cycles/sec  
See Overview/Product Selection  
On-Delay, One Shot, Pulse, and Flasher  
0.1...3 s, 3...60 s, 1...20 min, and 0.3...6 hr  
Timer Functions  
Timer Settings  
Timer Adjustments  
Timer Accuracy  
Min and Max adjustments with Potentionmeter  
Repeatability 1%, Recovery Time < 50 ms, Setting Accuracy Full Range 5%  
Coil Surge Protection  
Per EN 61000-4.5; Surge Immunity (801-5) Class III: 2 kV common and 1 kV differential mode  
Environmental  
Operating  
Storage  
–40…+55 °C (–40…+131 °F)  
–40…+100°C (–40…+212°F)  
2000 m (6560 ft)  
Temperature  
Altitude  
Construction  
Insulating Material  
Enclosure  
Molded High Dielectric Material  
RelayIP67  
Contact Material  
Terminal Markings on Socket  
Certifications  
Silver Tin Ox, AgSnO or Silver with Gold Plating, AgSnO + Au  
2
2
In accordance with EN50 0005  
cULus Listed (File No. E3125, Guide NLDX/NLDX7) with Allen-Bradley socket, CE Marked  
EN60947-4-1,EN60947-5-1,CSA 22.2,UL 508,NEMA IEE MAC Compliant, ICS-2 Compliant  
Standards  
(1) Product shall be installed in an enclosure providing at least IP54 protection. Provisions shall be made to prevent the rated voltage from being exceeded by transient disturbances of more than 40%.  
62  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Dimensions- 700-HLF Relays  
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.  
76.0  
(2.99)  
6.20  
(0.24)  
88.0  
(3.46)  
700-HLF Screw Terminal Design  
2
2
Single Wire: 0.14 mm …2.5 mm (#26 AWG…14 AWG)  
2
2
Double Wire: 2 x 0.14 mm …2 x 1.5 mm (2 x #26 AWG…2 x 16 AWG)  
Wire Type: Solid or stranded, copper only  
Strip Length: 9 mm (11/32 in.). Torque: 0.5 N•m (4.4 lb•in)  
12.5  
6.2  
(15/64)  
1.0  
(0.04)  
50  
(1-63/64)  
(1/2)  
5.2  
(13/64)  
35.0  
27.0  
(1.38)  
(1.06)  
7.5  
1000  
(0.3)  
(39-3/8)  
Cat. No. 199-DR1 DIN Mounting Rail Series B  
Cat. No. 199-DR4 DIN Mounting Rail Series B Has No Mounting Holes  
Cat. No.  
199-DR1  
199-DR4  
A
B
C
D
Approx. Shipping Wt.  
1.85 kg (4.07lb) (10/pkg)  
3.68 kg (8 lb) (5/pkg)  
35 (1-3/8)  
35 (1-3/8)  
27 (1-1/16)  
27 (1-1/16)  
7.5 (19/64)  
15 (19/32)  
1.02 (1/64)  
2.3 (3/32)  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
63  
Relay and Timer Specifications  
700-HP Slim Line Relay  
8 A contact ratings  
DPDT/ (2 c/o) contacts  
Plug-in PIN style (PCB) terminals (5 mm pinning)  
Choice of standard silver nickel contacts, or silver nickel with gold-plated contacts  
Available with mechanically linked contacts (Type B)  
Safety Control Relay Version (700-HPS)  
Wiring Diagrams  
U.S./Canada  
Contact  
Rating  
Coil  
Pkg.  
Photo  
Description  
Cat. No.  
Voltage Qty.  
International  
6V AC  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
10  
700-HPX2A06  
700-HPX2A12  
700-HPX2A24  
700-HPX2A1  
700-HPX2A2  
700-HPX2Z06  
700-HPX2Z12  
700-HPX2Z24  
700-HPX2Z48  
700-HPX2Z1  
700-HP32A06  
700-HP32A12  
700-HP32A24  
700-HP32A1  
700-HP32A2  
700-HP32Z06  
700-HP32Z12  
700-HP32Z24  
700-HP32Z48  
700-HP32Z1  
12V AC  
24V AC  
120V AC  
240V AC  
6V DC  
DPDT  
2-Pole  
2 Form C  
AgNi + Au  
Gold Plated  
Contacts  
12V DC  
24V DC  
48V DC  
110V DC  
6V AC  
8 A  
12V AC  
24V AC  
120V AC  
240V AC  
6V DC  
DPDT  
2-Pole  
2 Form C  
AgNi Contacts  
12V DC  
24V DC  
48V DC  
110V DC  
Sockets  
700-HN123  
700-HN123  
64  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
700-HPS Safety Control Relay  
Wiring Diagrams  
U.S./Canada  
Contact  
Rating  
Coil  
Voltage Qty.  
Pkg.  
Photo  
Description  
Cat. No.  
International  
6V DC 10  
700-HPSXZ06  
700-HPSXZ12  
700-HPSXZ24  
700-HPSXZ48  
700-HPSXZ60  
700-HPSXZ1  
700-HPSXZ01  
700-HPS2Z06  
700-HPS2Z12  
700-HPS2Z24  
700-HPS2Z48  
700-HPS2Z60  
700-HPS2Z1  
700-HPS2Z01  
12V DC 10  
24V DC 10  
48V DC 10  
60V DC 10  
110V DC 10  
125V DC 10  
DPDT 2-Pole  
2 Form C AgNi +  
Au Gold Plated  
Mechanically Linked  
Contacts  
8 A  
6V DC  
10  
12V DC 10  
24V DC 10  
48V DC 10  
60V DC 10  
110V DC 10  
125V DC 10  
DPDT 2-Pole  
2 Form C AgNi  
Mechanically Linked  
Contacts  
700-HPS DPDT  
Sockets  
700-HN123  
700-HN123  
Accessories - 700-HP, -HPS  
Pkg.  
Qty.  
Photo  
Description  
Cat. No.  
Diode Surge Suppressor  
10  
10  
10  
10  
10  
700-ADR  
Voltage Range: 6…220V DC used with 700-HN123 socket  
Diode with LED Surge Suppressor  
Voltage Range: 6…24V DC used with 700-HN123 socket  
700-ADL1R  
700-ADL2R  
700-ADL3R  
700-AV1R  
Diode with LED Surge Suppressor  
Voltage Range: 28…60V DC used with 700-HN123 socket  
Diode with LED Surge Suppressor  
Voltage Range: 110…220V DC used with 700-HN123 socket  
Diode with LED Surge Suppressor  
Voltage Range: 6…24V AC used with 700-HN123 socket  
Varistor with LED Surge Suppressor  
Voltage Range: 110…240V AC  
used with 700-HN123 socket  
10  
700-AV3R  
RC Surge Suppressor  
10  
10  
700-AR1  
700-AR2  
Voltage Range: 6…24V AC/DC used with 700-HN123 socket  
RC Surge Suppressor  
Voltage Range: 110…240V AC/DC used with 700-HN123 socket  
Timing Module  
On-Delay or One-Shot selectable voltage range: 12…24V AC/DC used with sockets  
that accept plug-in accessory modules.  
700-AT3  
Timing Module  
On-Delay or One-Shot selectable voltage range: 110…125V AC used with sockets  
that accept plug-in accessory modules.  
1
700-AT3A1  
700-AT3A2  
Timing Module  
On-Delay or One-Shot selectable voltage range: 230…240V AC used with sockets  
that accept plug-in accessory modules.  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
65  
Relay and Timer Specifications  
Pkg.  
Qty.  
Photo  
Description  
Cat. No.  
Screw Terminal Socket — Panel or DIN Rail Mounting  
10  
1
700-HN123  
8-pin miniature socket for use with 2-pole, 700-HP relays. Incorporates coil and contact separation.  
Red  
Gray  
Blue  
700-TBJ20R  
700-TBJ20G  
700-TBJ20B  
8-Way Jumper can be cut to required length. Rated 10 A – 250V  
Plastic Retainer and Ejection Lever  
For use with the 700-HN123 sockets  
10  
10  
10  
700-HN119  
700-HN230  
700-HN232  
Built-in ability to accept 1492 snap-in markers  
Spring Clamp Terminal Socket — Panel or DIN Rail Mounting  
8-pin miniature socket for use with 2-pole, 700-HP relays. Incorporates coil and contact separation.  
Plastic Retainer and Ejection Lever  
For use with the 700-HN230 sockets  
Built-in ability to accept 1492 snap-in markers  
DIN (#3) symmetrical hat rail  
35 x 7.5 x 1 m  
10  
199-DR1  
5
5
5
5
5
1492-MS5X12  
1492-MS6X9  
1492-MS6X12  
1492-MS8X9  
1492-MS8X12  
Relay Identification Snap-in Markers  
Note - These markers can only be used when the Plastic Retainer and Ejection Lever accessory (part # 700-  
HN119) is used because the markers snap into the Ejection Lever (and not into the relay itself).  
100  
1492-MP-Blank  
700-N40  
Pre-Printed Identification Tags — contains 10 sheets of pre-printed and blank tags. Each sheet contains 13  
sets of the markings CR…9CR, TR…9TR, M…9M, F, R, 1S, and 117 blank tags. Tags are peel-off with sticky  
backing for easy placement on relays.  
10  
700-N41  
Socket, and Retainer Clip Reference  
Relay Type  
700-HPX2  
700-HP32  
700-HPS2  
700-HPSX  
Socket Cat. No.  
700-HN123  
700-HN123  
700-HN123  
700-HN123  
Retainer Clip Cat. No.  
700-HN119  
700-HN119  
700-HN119  
700-HN119  
66  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
(1)  
Specifications - 700-HP Relays  
Cat. No. 700-HP…  
Cat. No. 700-HP3…, 700-HPX  
AC15@ 500V AC  
Cat. No. 700-HPS…  
C300  
B300  
VAC  
VDC  
1/3 Hp @ 240V AC  
1/6 Hp @ 120V AC  
1/2 Hp @ 240V AC  
1/3 Hp @ 120V AC  
Inductive  
AC-1 2000VA  
R300  
Contacts  
DC-1: 8A @ 30VDC  
DC-1: 0.3A @ 110V DC  
DC-1:0.1A @ 220V DC  
DC-1: 0.65A @ 110V DC  
DC-1:0.2A @ 220V DC  
AC  
DC  
8 A @ 277V AC (per pole)  
8 A @ 30V DC(per pole)  
Resistive  
700-HP32: 300mW (5V, 5 mA)  
700-HPX2: 50mW (5V,5 mA)  
700-HPS2: 500 mW (10V, 10 mA)  
700-HPSX: 50 mW (5V, 5 mA)  
Minimum Load  
Nominal Coil Power (AC/DC)  
OperatingRange(AC/DC)  
1.2 VA / 0.65 W  
0.7 W  
80...110% / 73...150%  
Nominal Voltage  
75...120%  
Nominal Voltage DC  
Holding Voltage (AC/DC)  
Must Drop Out Voltage (AC/DC)  
Insulation Voltage  
80/40%NominalVoltage  
20/10%NominalVoltage  
40% Nominal Voltage DC  
10% Nominal Voltage DC  
250VAC  
700-HPS  
2000V AC  
4000V AC  
DesignSpecification/TestRequirements  
700-HP3, 700-HPX  
Pole to Pole (VRMS)  
Dielectric Withstand Voltage  
for 1 minute  
Contact to Coil (VRMS)  
Mechanical  
Degree of Protection  
OpenType (Sockets)  
6
6
10 x 10 (AC Coils), 20 x 10  
(DCcoils)  
6
Mechanical lifecycles  
10 x 10 (DC Coils)  
Switching Frequency Operations  
Coil Voltages  
1800/hr (no load)  
900/hr (no load)  
10  
See Overview/Product Selection  
Operating Time at Nominal  
Voltage  
at 20 °C (ms)  
Pickup  
12  
Dropout  
4
Maximum Operating Rate  
16 Ops/s (full load)  
8 Ops/s (full load)  
Enclosure  
Fragility  
5 G  
2.5 G  
Vibration  
Endurance  
Fragility  
50 G  
Shock  
15 G  
Max. Socket Torque  
0.5 N•m(4.4 lb•in)  
Environmental  
Operating  
Storage  
–40…+85 °C (–40…+185 °F)  
–45…+100 °C (–49…+212 °F)  
–40…+70 °C (–40…+158 °F)  
–50…+80 °C (–40…+176 °F)  
Temperature  
Altitude  
2000 m (6560 ft)  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
67  
Relay and Timer Specifications  
(1)  
Specifications - 700-HP Relays  
Construction  
Insulating Material  
Enclosure  
Molded High-Dielectric Material  
Transparent Dust Cover Red Transparent Dust Cover  
Silver Nickel, (AgNi) (700-HP32 and 700-HPS2), Silver Nickel + Gold Plating  
(AgNi + Au) (700-HPX2 and 700-HPSX)  
Contact Material  
Terminal Markings on Socket  
In accordance with EN50 0005  
2-Pole  
Sockets  
700-HN123  
Approvals  
cURusRecognized(FileNo. E3125, GuideNLDX2/NLDX8), cULus Listed when  
used with 700-HN123 socket (File No. E3125, Guide NLDX/NLDC7), CSA  
Certified (files 229473), CE Marked, LR Certified (700-HP), IMQ & TÜV  
Certified (700- HPS)  
Certifications  
Standards  
UL 508, CSA 22.2 No. 14, EN 61810-1, EN 50205 (700-HPS)  
(1) The inrush VA equals 1.5 times the sealed VA.  
68  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Dimensions - 700-HP Relays  
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.  
29.0  
(1.14)  
12.4  
(0.49)  
25.0  
(0.98)  
700-HP Relay  
12.5  
(1/2)  
1.0  
(0.04)  
6.2  
(15/64)  
50  
(1-63/64)  
5.2  
(13/64)  
35.0  
27.0  
(1.38)  
(1.06)  
7.5  
1000  
(39-3/8)  
(0.3)  
Cat. No. 700-HN123  
2
Single Wire: 0.2.....2.5 mm (#24.....14 AWG)  
2
Double Wire: 2 X 0.2.....2 X 2.5 mm (#2 X 24....2 X 14 AWG)  
Wire Type: solid or stranded, copper only  
Strip Length: 7 mm (9/32 in.), Torque: 0.5 N•m (4.4 lb•in)  
Cat. No.  
199-DR1  
A
B
C
D
Approx. Shipping Wt.  
1.85 kg  
(4.07lb)  
(10/pkg)  
35  
(1-3/8)  
27  
(1-1/16)  
7.5  
(19/64)  
1.02  
(1/64)  
3.68 kg  
(8 lb)  
(5/pkg)  
35  
(1-3/8)  
27  
(1-1/16)  
15  
(19/32)  
2.3  
(3/32)  
199-DR4  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
69  
Relay and Timer Specifications  
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.  
60.9  
(2.40)  
17.5  
(0.69)  
21  
6
11  
3
17.5  
(0.69)  
24  
5
14  
4
21.6  
(0.85)  
12  
2
22  
7
Ø 3.2  
(0.12)  
Use M3 Screws  
78.6  
(3.09)  
35.4  
(1.39)  
8 (+)  
A1  
1 (-)  
A2  
21.6  
(0.85)  
4.0  
(0.16)  
15.8  
(0.62)  
Cat. No. 700-HN123  
2
Single Wire: 0.2.....2.5 mm (#24.....14 AWG)  
2
Double Wire: 2 X 0.2.....2 X 2.5 mm (#2 X 24....2 X 14 AWG)  
Wire Type: solid or stranded, copper only  
Strip Length: 7 mm (9/32 in.), Torque: 0.5 N•m (4.4 lb•in)  
Cat. No. 700-HN230  
Min wire size: 0.5mm2 (21 AWG.)  
Max wire size: 2 x 1.5 and 1 x 2.5 mm2 (2 x18 / 1 x 14 AWG)  
Wire Type: solid or stranded, copper only  
Stripe Length: 8mm (10/32 in.)  
70  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
700-HJ Magnetic Latching Relay  
10 A Contact Rating  
SPDT  
DPDT Single Coil  
DPDT Dual Coil  
Blade Style Quick Connect Terminals  
Wiring Diagrams  
AC(2)  
Contact  
Rating  
Photo  
Description  
Coil Voltage Cat. No.  
DC(3)  
24V AC  
700-HJ36A24  
700-HJ36A1  
120V AC  
SPDT  
1-Pole  
1 Form C  
AgCdO Contacts  
(Single Coil  
AC or DC)  
10 A  
24V DC  
700-HJ36Z24  
Sockets  
700-HN153  
700-HN154  
24V AC  
700-HJ32A24  
700-HJ32A1  
700-HJ32A2  
120V AC  
240V AC  
DPDT  
2-Pole  
2 Form C  
AgCdO Contacts  
(Single Coil  
AC or DC)  
10 A  
12V DC  
24V DC  
700-HJ32Z12  
700-HJ32Z24  
Sockets  
700-HN153  
700-HN154  
DPDT  
2-Pole  
2 Form C  
AgCdO Contacts  
10 A  
DC Only  
24V DC  
700-HJD32Z24  
(Dual Coil(1)  
700-HN153 or  
700-HN154  
Sockets  
(1) Available only in DC Coil with DPDT contacts.  
(2) AC Relays include internal diodes.  
(3) For DC operation, polarity must be observed.  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
71  
Relay and Timer Specifications  
Accessories-700-HJ Relays  
Photo  
Description  
Pkg. Qty.  
Cat. No.  
Screw Terminal Socket — Panel or DIN Rail Mounting. Guarded Terminal Construction  
11-blade socket for use with 700-HB relays. This socket has coil and contact separation as well as the  
ability to use optional plug-in modules ( 700-A__ accessories, LED, surge suppression, timing modules).  
10  
700-HN153  
Screw Terminal Base Socket — Panel or DIN Rail Mounting. Open Style Construction  
10  
10  
700-HN154  
199-DR1  
11-blade for use with 700-HB relays.  
DIN (#3) symmetrical hat rail  
35 x 7.5 x 1 m  
Retainer Clip  
For Cat. Nos. 700-HN153 and -HN154 Sockets with 700-HJ Relays  
Secures relay in socket. Order must be for 10 clips or multiples of 10.  
10  
10  
700-HN159  
Pre-Printed Identification Tags — contains 10 sheets of pre-printed and blank tags. Each sheet  
contains 13 sets of the markings CR…9CR, TR…9TR, M…9M, F, R, 1S, and 117 blank tags. Tags are  
peel-off with sticky backing for easy placement on relays.  
700-N40  
700-N41  
Blank Identification Tags — contains 10 sheets of blank identification tags for customer specialized  
printing. Each sheet contains 546 blank tags. Tags are peel-off with sticky backing for easy placement on 10  
relays.  
Socket and Retainer Clip Reference  
Relay Type  
Socket Cat. No.  
700-HN153  
Retainer Clip Cat. No.  
700-HN159  
700-HJ  
700-HN154  
700-HN159  
Specifications - 700-HJ Relays  
Attribute  
700-HJ  
Electrical Ratings  
Pilot Duty Rating  
Rated Thermal Current (I  
)
10 A  
th  
250VIEC,  
300V UL/CSA  
Rated Insulation Voltage(Ui)  
Make  
Break  
Hp  
Inductive  
Contacts  
120VAC  
240VAC  
30 A  
15 A  
3 A  
1.5 A  
1/4  
1/3  
DC  
24V DC, 10 A  
85…110% of Nominal Voltage at 50 Hz  
85…110% of Nominal Voltage at 60 Hz  
80…110% of Nominal Voltage at DC  
Permissible Coil VoltageVariation  
72  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Specifications - 700-HJ Relays  
Single  
AC Coil  
Single  
DC Coil  
Dual  
DC Coil  
1.44 VA  
1.44 VA  
Inrush  
Sealed  
AC Coils  
DC Coils  
CoilConsumption 10%  
12V 1.63 W  
24V 1.67 W  
1.2 W  
DesignSpecification/TestRequirements  
Pole-to-Pole  
1500V AC  
1500V AC  
1500V AC  
Dielectric Withstand Voltage  
Degree of Protection  
Contact-to-Pole  
Contact-to-Frame  
Mechanical  
Open Type  
(Guarded Terminal Sockets)  
6
Mechanical Life Operations  
Switching Frequency Operations  
Coil Voltages  
10 x 10  
1800/HR  
See Product Selection  
Pickup  
Dropout  
25 ms  
25 ms  
Operating Time at Nominal Voltage at 20 °C  
Maximum Operating Rate  
Environmental  
Construction  
–45…+50 °C  
Operating  
Storage  
(–49…+122 °F)  
Temperature  
Altitude  
–45…+100 °C  
(–49…+212 °F)  
2000 m (6560 ft)  
Insulating Material  
Enclosure  
Molded High Dielectric Material  
Transparent Dust Cover  
Contact Material  
Terminal Markings on Socket  
Silver Cad. Ox.  
In accordance with EN50 0005  
11-Blade Socket  
Cat. No. 700-HN153  
Cat. No. 700-HN154  
Sockets  
Certifications  
Standards  
CSA Certified, File LR700026, UL Recognized, File E3125, Guide NLDX 2  
UL 508, CSA 22.2 No. 14, EN/IEC 60947-4-1, -5-1  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
73  
Relay and Timer Specifications  
Dimensions - 700-HJ Relays  
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.  
700-HJ Relay  
Cat. No. 700-HN153  
Wire Size: 2 x 2.5 mm  
2
Single Wire – Up to #12 AWG  
2
Double Wire – 2 x 2.5 mm (#2–14 AWG… #2–20 AWG)  
(Either Solid or Stranded)  
Strip Length: 9 mm (3/8 in) – Torque: 0.8 N•m (7 lb•in  
Cat. No. 700-HN154  
Wire Size: 2 x 2.5 mm  
2
Single Wire – Up to #12 AWG  
2
Double Wire – 2 x 2.5 mm (#2–14 AWG… #2–20 AWG)  
(Either Solid or Stranded)  
Strip Length: 9 mm (3/8 in) – Torque: 0.8 N•m (7 lb•in)  
12.5  
(1/2)  
1.0  
(0.04)  
6.2  
(15/64)  
50  
(1-63/64)  
5.2  
(13/64)  
35.0  
27.0  
(1.38)  
(1.06)  
7.5  
1000  
(0.3)  
(39-3/8)  
Cat. No. 199-DR1 DIN Mounting Rail Series B  
Cat. No. 199-DR4 DIN Mounting Rail Series B Has No Mounting Holes  
Cat. No.  
199-DR1  
199-DR4  
A
B
C
D
Approx. Shipping Wt.  
1.85 kg (4.07lb) (10/pkg)  
3.68 kg (8 lb) (5/pkg)  
35 (1-3/8)  
35 (1-3/8)  
27 (1-1/16)  
27 (1-1/16)  
7.5 (19/64)  
15 (19/32)  
1.02 (1/64)  
2.3 (3/32)  
74  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
700-HG Power Relay  
40 A Contact Ratings  
SPST-NO-DM, SPDT, DPST-NO, DPDT  
Panel Mounted  
Options: Magnetic Blowout for High DC Loads, Auxiliary Snap Action Switch  
Screw Terminals #6-32 for Coil, #8-32 for Contacts  
Description  
Contact Ratings  
Wiring Diagrams  
Coil Voltage  
24V AC  
Cat. No.(1)  
700-HG45A24  
700-HG45A1  
700-HG45A2  
700-HG45A27  
700-HG45A4  
700-HG45Z12  
700-HG45Z24  
700-HG45Z48  
700-HG45Z1  
700-HG46A24  
700-HG46A1  
700-HG46A2  
700-HG46Z12  
700-HG46Z24  
700-HG46Z48  
700-HG46Z1  
700-HG47A24  
700-HG47A1  
700-HG47A2  
700-HG47A4  
700-HG47Z12  
700-HG47Z24  
700-HG47Z48  
700-HG47Z1  
700-HG42A24  
700-HG42A1  
700-HG42A2  
700-HG42A27  
700-HG42Z12  
700-HG42Z24  
700-HG42Z48  
700-HG42Z1  
700-HG42Z2  
700-HG42Z25  
120V AC  
240V AC  
277V AC  
480V AC  
12V DC  
SPST-NO-DM  
1 Form X  
40 A  
(A600)  
AgCdO Contacts  
24V DC  
48V DC  
110V DC  
24V AC  
120V AC  
240V AC  
12V DC  
SPDT  
1-pole  
1 Form C  
AgCdO Contacts  
40 A  
(A600)  
24V DC  
48V DC  
110V DC  
24V AC  
120V AC  
240V AC  
480V AC  
12V DC  
DPST-NO  
2-pole  
40 A  
(A600)  
2 Form A  
AgCdO Contacts  
24V DC  
48V DC  
110V DC  
24V AC  
120V AC  
240V AC  
277 AC  
DPDT  
2-pole  
2 Form C  
AgCdO Contacts  
12V DC  
40 A  
(A600)  
24V DC  
48V DC  
110V DC  
220V DC  
250V DC  
(1) Auxiliary Snap Switch Option: Add suffix (-5) to the selected 700-HG relay Cat. No., except for the 220V DC add (-5L).  
Magnetic Blowout Option: Add suffix (-6) to the selected 700-HG relay Cat. No. (suppresses the arc when switching DC loads – ratings listed below).  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
75  
Relay and Timer Specifications  
Accessories - 700-HG Relays  
Pkg.  
Qty.  
Photo  
Description  
Cat. No.  
Pre-Printed Identification Tags — contains 10 sheets of pre-printed and blank tags. Each  
sheet contains 13 sets of the markings CR…9CR, TR…9TR, M…9M, F, R, 1S, and 117 blank tags. 10  
Tags are peel-off with sticky backing for easy placement on relays.  
700-N40  
Blank Identification Tags — contains 10 sheets of blank identification tags for customer  
specialized printing. Each sheet contains 546 blank tags. Tags are peel-off with sticky backing for 10  
easy placement on relays.  
700-N41  
Type 1 Enclosure For use with any of the listed relays. Knockouts for 1/2 in. and 3/4 in. conduit  
connections. The enclosure exceeds the minimum clearances required by U.S. standards, resulting  
in generous wiring spaces.  
1
700-HN120  
Auxiliary Snap Action Switch  
Contact  
Material  
Silver Cad. Ox.  
Rating  
Dielectric Withstand V (1 Min.)  
SPDT (1 Form C)  
10 A at 120 or 240 Resistive  
1500V AC RMS Contact to Frame  
76  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Specifications - 700-HG Relays  
Attribute  
700-HG  
Electrical Ratings  
Pilot Duty Rating (1)  
A600  
40 A  
Rated Thermal Current (I  
)
th  
Rated Insulation Voltage(Ui)  
600V UL  
Contact Ratings: AC Ratings SPST-NO-DM  
Contact Ratings: AC Ratings SPDT, DPST - NO and DPDT  
Inductive  
Resistive -  
Make/Break  
and  
Inductive  
Resistive -  
Make/Break  
and  
Volts  
HP Volts  
HP (2)  
Make  
Break  
Continuous  
Make  
Break  
Continuous  
Continuous  
Continuous  
120  
60 A  
30 A  
15 A  
12 A  
6 A  
3 A  
10 A  
10 A  
10 A  
10 A  
40 A  
40 A  
12 A  
10 A  
120  
60 A  
30 A  
15 A  
15 A  
6 A  
3 A  
10 A  
10 A  
10 A  
10 A  
40 A  
40 A  
5 A  
2
1 - 1/2  
1 - 1/2  
240  
240  
480V  
600V  
1.5 A  
1.2 A  
480  
1.5 A  
1.2 A  
2
600  
5 A  
DC Ratings: Without Magnetic Blowouts - 28V 40 A - Make, Break and Continuous Est Drop 125V 1.2...3 A  
SPST - NO -  
DC Ratings: With Magnetic Blowouts:  
DM  
SPDT, DPST - NO and DPDT  
110V  
220V  
325V  
500V  
20 A  
8 A  
4 A  
2 A  
10 A  
4 A  
2 A  
Make, Break, and Continuous  
80…100% of Nominal Voltage at 50 Hz  
85…110% of Nominal Voltage at 60 Hz  
80…110% of Nominal Voltage at DC  
Permissible Coil Voltage Variation  
50 HZ  
60 HZ  
Inrush  
Sealed  
13 VA  
10 VA  
16 VA  
11 VA  
AC Coils  
Coil Consumption 10%  
DC Coils  
2.0 W  
Design Specification/Test Requirements  
2200V AC  
Pole-to-Pole  
ContacttoPole  
Contact to Frame  
Dielectric Withstand  
Voltage  
2200V  
2200V AC  
Mechanical  
Degree of Protection  
Open Type  
6
Mechanical Life Operations  
5 x 10  
Switching Frequency Operations  
Coil Voltage  
1600/Hr  
See Overview/Product Selection  
Operating Time at Nominal  
Voltage at 20 °C (68 °F)  
Pickup  
Dropout  
40 ms  
35 ms  
Maximum Operating Rate  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
77  
Relay and Timer Specifications  
Specifications - 700-HG Relays  
Environmental  
Construction  
Operating  
Storage  
30…+55 °C (-22...+149 °F)  
-30…+65 °C (-22...+149 °F)  
2000 m (6560 ft)  
Temperature  
Altitude  
Molded Thermo  
Insulating Material  
Setting Plastic  
Enclosure  
Contact Material  
Terminal Markings on Socket  
Sockets  
Silver Cadmium Oxide  
Certifications  
Standards  
CSA Certified, File 225674, UL Listed, File E3125, Guide NLDX, CE Marked  
UL 508, CSA 22.2 No. 14, EN/IEC 60947-1, -5-1  
(1) NEMA Rating Chart is on page 19 of publication 700-SG003B-EN-P.  
(2) For DPDT only: 2 Hp Switching 2 Poles, 200...600V AV, 50/60 Hz.  
78  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Dimensions - 700-HG Relays  
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.  
700-HG Relay, SPST-NO-DM  
700-HG Relay  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
79  
Relay and Timer Specifications  
700-HHF Flange Mount Power Relay  
Flange-Mounted  
Blade Style 0.250 x 0.032 Quick Connect/Solder (no socket) Terminals  
Solder Terminals (no socket)  
Wiring Diagrams  
Description  
Contact Rating  
Coil Voltage  
Cat. No.  
U.S./Canada  
International  
120V AC  
700-HHF45A1  
SPST-NO-DM  
1 Form X  
AgCdO Contacts  
30 A  
(A600)  
24V DC  
700-HHF45Z24  
24V AC  
120V AC  
240V AC  
12V DC  
700-HHF62A24  
700-HHF62A1  
700-HHF62A2  
700-HHF62Z12  
DPDT  
2-Pole  
25 A  
(B600)  
2 Form C  
AgCdO Contacts  
24V DC  
700-HHF62Z24  
3PDT  
3-Pole  
20 A  
(B300)  
120V AC  
700-HHF73A1  
3 Form C  
AgCdO Contacts  
Specifications - 700-HHF Relays  
Attribute  
700-HHF…  
Electrical Ratings  
SPST-NO-DM  
NEMAA600  
NEMA B600  
NEMA B300  
Pilot Duty Rating (1)  
DPDT  
3PDT  
Rated Thermal Current (I  
)
SPST-NO-DM 30 A, DPDT 25A, 3PDT 20 A  
250V IEC-300V UL/CSA  
th  
Rated Insulation Voltage(Ui)  
Inductive  
SPST-NO-DM  
Hp  
DPDT  
Hp  
3PDT  
Hp  
Contacts  
120VAC  
240VAC  
DC  
60 A  
30 A  
6 A  
3.0 A  
28V DC, 30 A  
1
30 A  
15 A  
3 A  
1.5 A  
1
30 A  
15 A  
3 A  
1.5 A  
1/2  
1-1/2  
1-1/2  
28V DC, 13 A  
80  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Specifications - 700-HHF Relays  
Attribute  
700-HHF…  
85…110% of Nominal Voltage at 50 Hz  
85…110% of Nominal Voltage at 60 Hz  
80…110% of Nominal Voltage at DC  
DPDT  
Permissible Coil Voltage Variation  
SPST-NO-DM  
50 Hz  
3PDT  
50 Hz  
60 Hz  
50 Hz  
60 Hz  
6.3 VA  
4.2 VA  
60 Hz  
Inrush  
Sealed  
7.2 VA  
6.3 VA  
4.2 VA  
7.2 VA  
4.8 VA  
7.2 VA  
4.8 VA  
6.3 VA  
4.2 VA  
Coil  
Consumption  
10%  
AC Coils  
DC Coils  
4.8 VA  
1.4 W  
25%of VA  
10% of W  
Max. Allowable Leakage  
Design Specification/TestRequirements  
Pole-to-Pole  
Dielectric Withstand  
Contact-to-Pole  
Voltage  
2200V AC  
2200V AC  
1600VAC  
Contact-to-Frame  
Mechanical  
6
Mechanical Life Operations  
Switching Frequency Operations  
Coil Voltages  
5 x 10  
3600/Hr  
See Overview/Product Selection  
Pickup  
20 ms  
15 ms  
Operating Time at Nominal  
Voltage at 20 °C  
Dropout  
Maximum Operating Rate  
4 Ops/s.  
Environmental  
–30…+50 °C  
(–22…+122 °F)  
–30…+100 °C  
(–22…+212 °F)  
2000 m (6560 ft)  
Operating  
Temperature  
Storage  
Altitude  
Construction  
Insulating Material  
Enclosure  
Molded High Dielectric Material  
Transparent Dust Cover  
Contact Material  
Terminal Markings  
Sockets  
Silver Cadmium Oxide  
In accordance with EN50 0005  
(2)  
Certifications  
cURus Recognized, File E3125,Guide NLDX2/NLDX8, CE Marked  
UL 508, CSA 22.2 No.14, EN/IEC 60947-1, -5-1  
Standards  
(1) See NEMA Ratings and Test Values on page 5.  
(2) 700-HHF relay wiring and terminals are the quick connect / solder type 6.35 x 0.82 mm (0.250 x 0.032 in) termination.  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
81  
Relay and Timer Specifications  
Dimensions - 700-HHF Relays  
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.  
35.7  
(1-13/32)  
3.97  
(5/32)  
63.5  
(2-1/2)  
38.9  
(1-17/32)  
73.8  
(2-29/32)  
700-HHF Relay  
82  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
700-HTA Alternating Relay  
Alternating Relay  
Rugged Pin Style Socket Mounting  
10 A, SPDT, DPDT, and Cross Wired  
Excellent for Pump Panel Applications  
700  
HTA  
2
A12  
7
a
b
c
d
e
Catalog Number Explanation - 700-HTA Relays  
a
b
c
d
e
-
Bulletin Number  
Relay Type  
Model Type  
Coil Voltage  
Gold Plated Contacts Option  
A12 - 12V AC 50/60 Hz  
A24 - 24V AC 50/60 Hz  
A1 - 120V AC 50/60 Hz  
A2 - 240V AC 50/60 Hz  
1 - SPDT  
2 - DPDT  
3 -Cross-Wired  
Blank - Without switch  
7 - With switch  
HTA - Tube Base  
Alternating Relay  
700  
Alternating Relays with Pin-Style Terminations  
Wiring Diagrams  
U.S./Canada  
700-HTA  
Alternating Relay  
International  
SPDT Form C Contact  
SPDT  
DPDT 2 Form C Contact  
DPDT  
Cross-Wired DPDT 2 Form C  
Contacts  
Cross-Wired  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
83  
Relay and Timer Specifications  
Accessories - 700-HTA Relays  
Photo  
Description  
Pkg. Qty. Cat. No.  
Screw Terminal Tube Base Socket — Panel or DIN Rail Mounting; Guarded Terminal Construction. 8-Pin  
10  
10  
700-HN100  
700-HN125  
for use with 700-HTA1A or -HTA3A alternating relays. Order ten or multiples of ten.  
Screw Terminal Tube Base Socket — Panel or DIN Rail Mounting; Open Style Construction. 8-Pin for use  
with 700-HTA1A or -HTA3A alternating relays. Order ten or multiples of ten. No retainer clip required.  
Screw Terminal Tube Base Sockets — Panel or DIN Rail Mounting; Guarded Terminal Construction. 11-  
10  
10  
700-HN101  
700-HN126  
pin for use with 700-HTA2A alternating relays. Order in multiples of 10.  
Screw Terminal Tube Base Sockets — Panel or DIN Rail Mounting; Open Style Terminal  
Construction. 11-pin for use with 700-HTA2A alternating relays. Order in multiples of 10. No retainer clip required.  
DIN (#3) symmetrical hat rail  
10  
10  
199-DR1  
35 x 7.5 x 1 m  
Retainer Clip for Cat. Nos. 700-HN100 and -HN101 Sockets with 700-HT Timing Relays, and 700-HTA  
Alternating Relays  
Secures relay in socket. Order must be for 10 clips or multiples of 10.  
700-HN110  
700-N40  
Pre-Printed Identification Tags — contains 10 sheets of pre-printed and blank tags. Each sheet contains 13 sets  
of the markings CR…9CR, TR…9TR, M…9M, F, R, 1S, and 117 blank tags. Tags are peel-off with sticky backing for 10  
easy placement on relays.  
Blank Identification Tags — contains 10 sheets of blank identification tags for customer specialized printing.  
Each sheet contains 546 blank tags. Tags are peel-off with sticky backing for easy placement on relays.  
10  
700-N41  
84  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Specifications - 700-HTA Relays  
Attribute  
700-HTA  
ElectricalRatings  
Pilot Duty Rating (1)  
NEMA B300 AC 15  
10 A  
Rated Thermal Current (I  
)
th  
Rated Insulation Voltage(Ui)  
250V IEC, 300V UL/CSA  
Inductive  
Make  
Break  
HP  
Contacts  
120VAC  
30 A  
15 A  
10 A  
3 A  
1.5 A  
10 A  
1/3  
1/2  
240VAC  
Resistive 30V DC  
85…110% of Nominal Voltage at 50 Hz  
85…110% of Nominal Voltage at 60 Hz  
Permissible Coil Voltage Variation  
Power Consumption 10%  
24VAC  
2 VA  
4 VA  
4 VA  
AC  
120VAC  
240VAC  
Design Specification/TestRequirements  
Pole-to-Pole, same circuit  
1000V AC  
2000V AC  
(VRMS)  
Dielectric Withstand Voltage  
Pole-to-Pole, different circuits  
(VRMS)  
Contact-to-Coil (VRMS)  
2000V AC  
100,000 minimum  
1800/hr  
Electrical Life Operations  
Switching Frequency Operations  
Coil Voltages  
See product selection  
Mechanical  
Degree of Protection  
Open Type (Guarded Terminal Sockets)  
6
Mechanical Life Operations  
Switching Frequency Operations  
10 x 10  
18,000/hr  
0.05 sec  
Start-up Time (max. time from power application until unit is timing)  
Max. Function Time (max. time power can drop out and unit continues timing)  
Min. Cycle Time  
0.01 sec  
100 ms on release of the control switch  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
85  
Relay and Timer Specifications  
Specifications - 700-HTA Relays  
Attribute  
700-HTA  
Environmental  
Construction  
–28…+65 °C (50 °C max., 240V AC coil)  
(–18…+149 °F) (122 °F max., 240V AC coil)  
Operating  
Storage  
Temperature  
Altitude  
–55…+85 °C  
(–67…+185 °F)  
2000 m (6560 ft)  
Insulating Material  
Enclosure  
Molded High Dielectric Material  
Impact Resistant Dust Cover  
Silver Tin Oxide  
Contact Material  
Terminal Markings on Socket  
In accordance with EN50 005  
8- or 11-Pin Socket 700-HN100, -HN125  
700-HN101, -HN126  
Sockets  
CSA Certified, File 223833, UL Recognized (File E3125 Guide NLDX2/NLDX8),  
cULus Listed with 700-HN100, 700-HN101, 700-HN125, and 700-HN126  
Sockets (File No. E3125 Guide NLDX/NLDX7), CE-Marked  
(per EU Low Voltage Directive)  
Certifications  
Standards  
EN 61812-1, CSA 22.2 No. 14, UL 508  
(1) See NEMA Ratings and Test Values on page 5.  
86  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Trigger Signal Cat. Nos. 700-HTA  
Contact closure provides signal to timer. The 700-HTA alternating relay generates a low energy signal. For optimum reliability, use contacts  
designed for low energy switching (10V, 1 mA) (Example: Bul. 800F-X_V, 800T-X_V). No external voltage can be connected to the contact signal.  
Load Diagrams - 700-HTA Relays  
Cross Wired Lead/Lag/Lag/lead Sequence  
Common Input/Output SPDT/DPDT  
Lead  
Lag  
B1  
Load A  
Load B  
LED A  
LED B  
Load A  
Load B  
LED A  
LED B  
Power  
Power  
Socket  
Pinout Map  
DPDT  
Socket  
Pinout Map  
SPDT  
Socket  
Pinout Map  
Cross-Wired  
Relay  
A1  
A2  
Socket  
4
8
Relay  
A1  
A2  
Socket  
4
3
Relay  
A1  
A2  
Socket  
3
6
Note: pin out in wiring diagram may not match actual printed  
socket see pinout map for wiring up the power source  
Note: pin out in wiring diagram may not match actual printed  
socket see pinout map for wiring up the power source  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
87  
Relay and Timer Specifications  
Dimensions - 700-HTA Relays  
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.  
79  
(3-7/64)  
74  
(2-29/32)  
60  
(2-23/64)  
43  
(1-11/16)  
24.6  
(31/32)  
40.1  
(1-37/64)  
20.8  
(53/64)  
30.0  
(1-3/16)  
26  
(1-1/32)  
24.9  
(63/64)  
54.9  
(2-5/32)  
65.0  
(2-35/64)  
51.1  
(2-1/64)  
4.2  
(5/32)  
38.0  
(1-1/2)  
33.0  
(1-19/64)  
#4–40  
M3  
14.7  
(37/64)  
Cat. No. 700-HN100  
Cat. No. 700-HN125  
Wire Size: 2 x 2.5 mm  
2
Panel Mounting  
2
Double Wire — 2 x 2.5 mm (#2 – 14 AWG…#2 – 20 AWG)  
(Either Solid or Stranded)  
Single Wire — Up to #12 AWG  
2
Double Wire — 2 x 2.5 mm (#2 – 14 AWG… #2 – 20 AWG)  
(Either Solid or Stranded)  
Strip Length: 9 mm (3/8 in) – Torque: 0.8 N•m (7 lb•in)  
Strip Length: 9 mm (3/8 in) — Torque: 0.8 N•m (7 lb•in)  
59.2  
(2-1/3)  
24.6  
(31/32)  
20.8  
(53/64)  
26  
(1-1/32)  
7.9  
(0.31)  
30  
(1-3/16)  
26.9  
(1.06)  
54.9  
(2-5/32)  
65.0  
(2-35/64)  
51.1  
(2-1/64)  
4.2  
(5/32)  
38.0  
(1-1/2)  
#4-40  
M3  
52.3  
(2.06)  
Cat. No. 700-HN101  
Cat. No. 700-HN126  
Wire Size: 2 x 2.5 mm  
2
Panel Mounting  
2
Double Wire – 2 x 2.5 mm (#2 – 14 AWG…#2 – 20 AWG)  
(Either Solid or Stranded)  
Single Wire — Up to 12 AWG  
2
Double Wire — 2 x 2.5 mm (#2 – 14 AWG…#2 – 20 AWG)  
(Either Solid or Stranded)  
Strip Length: 9 mm (3/8 in) – Torque: 0.8 N•m (7 lb•in)  
Strip Length: 9 mm (3/8 in) — Torque: 0.8 N•m (7 lb•in)  
88  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
General Purpose Electronic Timers and Counters  
Product Overview  
700-HR52, -HRP,  
-HRS, -HRT, -HRV  
Bulletin No.  
Type  
700-FE  
700-FS  
700-HRM/-HRC  
700-HRF  
DIN Rail Timer  
DIN Rail Timer  
Multifunction Timer  
On-Delay Timer  
Twin Timer  
Dial timing relays  
5 A contact rating  
Multiple programmable  
timing ranges  
Only 22.5 mm wide  
8 A contact rating  
Multifunction or single  
function  
Dial timing relays  
5 A contact rating  
Multiple programmable  
timing ranges  
Only 17.5 mm wide  
5 A contact rating  
Multifunction or single  
function  
No additional socket  
required  
Tube base pin style  
terminals  
Independent ON and  
OFF settings  
14 time ranges  
8-pin models available  
Dial timing relays  
UL508  
No additional socket  
required  
Tube base pin-style  
terminals  
Multi-voltage inputs  
Timed contacts and  
instantaneous contacts  
Transistor outputs  
Single function and  
multi-function  
Features  
Optional:  
Multi-voltage inputs  
Timed contacts and  
instantaneous contacts  
Transistor outputs  
Single function and  
multi-function  
Star-delta timing  
function  
True off-delay timing  
function  
Hazardous location  
certification  
7 different operating  
modes  
Control Outputs:  
Time Limit  
Instantaneous  
SPDT or DPDT or  
2 N.O. + 1 common  
DPDT Timed, Transistor  
DPDT Timed, Transistor  
1 N.O. or SPDT timed  
DPDT Timed  
SPDTTimed/Instantaneous SPDTTimed/Instantaneous  
On-Delay  
Off-Delay  
One Shot  
Repeat Cycle Off Start  
Repeat Cycle On Start  
Signal On/Off-Delay  
On-Delay One Shot  
On-delay  
Off-delay  
One shot  
Repeat Cycle Off Start  
Repeat Cycle On Start  
Operation Modes:  
11 timing modes  
0.05 s…60 hr  
On-Delay  
Repeat cycle-pulse  
Fleeting off-delay  
Pulse converter  
Time Range  
0.05 s…10 hr  
0.05 s…300 h  
0.05 s…300 h  
0.05 s…300 h  
24V AC/DC  
12…48V DC  
24…48V AC  
100…240V AC  
100…125V DC  
12…48V DC  
24…48V AC  
100…240V AC  
100…125V DC  
12V DC  
12V DC  
24V…48V DC  
24V…240V AC  
110…240V AC  
24…48V AC/DC  
24…240V AC  
24V AC/DC  
Supply Voltage  
48…125V DC  
100…240V AC  
Contact Rating at 120V  
AC  
5 A  
8 A  
5 A  
5 A  
5 A  
Certifications  
Socket Cat. No(s).  
Page  
CE, cULus  
CE, cULus  
cURus, CE, C-Tick  
cURus, CE, C-Tick  
cURus, CE, C-Tick  
700-HN100 OR 700-HN101 700-HN100  
700-HN125 OR 700-HN126 700-HN125  
700-HN100  
700-HN125  
DIN Rail or panel mount  
92  
DIN Rail or panel mount  
96  
116  
117  
117  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
89  
Relay and Timer Specifications  
Bulletin No.  
Type  
700-HRY  
Star-Delta Timer  
700-HRQ  
700-HNC  
700-HNK  
True Off-Delay Timer  
Miniature Timer  
Ultra-Slim Timer  
Ultra-slim timing relay  
Four different operating  
modes  
A wide star-time range  
(up to 120 s)  
Dial timing relays  
Long power Off-delay times  
11-pin and 8-pin models are  
available  
Four different operating modes  
DIN Rail mount with socket  
Pin configuration same as 700-HC  
relay  
Three operating voltages  
DIN Rail mount with  
socket  
Features  
Star-delta transfer time range  
(up to 0.5 s)  
UL Recognized  
UL Recognized  
Pin configuration same as  
700-HK relay  
Control Outputs:  
Time Limit  
Instantaneous  
SPST (Star, Delta) Timed  
SPST - NO Instantaneous  
DPDT Timed  
4PDT  
SPDT, DPST-NO  
On-Delay  
On-Delay  
True OFF-delay Timer  
True OFF-delay Timer w/reset  
One Shot  
One Shot  
Operation Modes: Star-Delta  
Repeat Cycle Off Start  
Repeat Cycle On Start  
Repeat Cycle Off Start  
Repeat Cycle On Start  
Time Range  
0.5 s…120 s  
0.05 s…12 min  
0.1 s…10 h  
0.1 s…10 h  
48V DC  
12V DC  
12V DC  
24V DC  
24V AC  
100…120V AC  
200…240V AC  
24V AC/DC  
24V AC/DC  
Supply Voltage  
100…240V AC  
100…125V DC  
48…125V DC  
100…240V AC  
Contact Rating at  
120V AC  
5 A  
5 A  
5 A  
5 A  
Certifications  
Socket Cat. No(s).  
Page  
cURus, CE, C-Tick  
cURus, CE, C-Tick  
cURus, CSA, CE, C-Tick  
cURus, CE, ACA  
700-HN100  
700-HN125  
700-HN100 OR 700-HN101  
700-HN125 OR 700-HN126  
700-HN103  
700-HN128  
700-HN121  
700-HN122  
117  
118  
103  
109  
90  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Bulletin No.  
700-HT  
700-HV  
700-HX  
Type  
Tube Base Timing Relay  
Repeat-Cycle Timing Relay  
Digital Timer  
Digital timer  
5 A contact rating  
Negative transmissive LCD display  
10 functions or modes  
Pin-style terminals  
Single range or fixed timers  
Available as ON- or OFF-Delays  
Pin-style terminals  
Single-range timer  
Repeat cycle  
Features  
Environmentally friendly—flash memory, no  
battery  
NEMA B300 rated  
NEMA 4/IP66  
DIN Rail or panel mount capable  
Control Outputs:  
Time Limit Instantaneous  
DPDT  
DPDT  
SPDT  
Signal On-Delay 1 and 2  
Signal Off-Delay  
One Shot  
On-Delay  
Off-Delay  
Repeat Cycle Off Start  
Repeat Cycle On Start  
Signal On/Off-Delay  
Power On-Delay 1 and 2  
Twin Timer Cumulative  
Timing Operation Modes:  
Repeat Cycle  
Time Range  
0.1 s…30 min.  
0.1 s…30 min.  
0.05 s…300 h  
12V DC  
24V DC  
24V AC  
120V AC  
240V AC  
24V DC  
24V AC  
120V AC  
240V AC  
12…24V DC  
24V AC  
100…240V AC  
Supply Voltage  
Contact Rating at 120V AC  
Certifications  
10 A  
10 A  
5 A  
UR, UL, CSA, CE  
UR, UL, CSA, CE  
cURus, CE, C-Tick  
700-HN100 OR 700-HN101  
700-HN125 OR 700-HN126  
700-HN100  
700-HN125  
700-HN100  
700-HN125  
Socket Cat. No(s).  
Page  
128  
133  
138  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
91  
Relay and Timer Specifications  
700-FE Economy Timing Relay  
Adjustable function and timing range timing relays  
DIN Rail mounted without cost of socket  
17.5 mm wide, multi-function or single function  
Available as 1 N.O. or SPDT contact output, 5 A  
Timing ranges from 0.05 s…10.0 hr  
Coil surge protection  
Multi-Function  
This device offers you the flexibility of selecting one of 4 single timing functions.  
Operating Mode  
Contact Output  
Timing Range(1)  
Input Voltage  
Cat. No.  
(2)  
24V AC/DC  
ON-delay, OFF-delay, One Shot, Flasher (repeat cycle starting with  
pulse)  
1 N.O.  
0.05 s…10 hr (6 settings)  
110…240V AC  
50/60 Hz  
700-FEM1TU22  
24V…48V AC/DC  
24…240V AC  
50/60 Hz  
ON-delay, OFF-delay, One Shot, Flasher (repeat cycle starting with  
pulse)  
SPDT (1 C/O)  
0.05 s…10 hr (6 settings)  
700-FEM3TU23  
(1) Time ranges: 0.05 s…1 s, 0.5…10 s, 0.05…1 min, 0.5…10 min, 0.05…1 hr, 0.5…10 hr.  
(2) Voltage is either 24V AC/DC 50/60 Hz.  
Single-Function  
This device offers you one specific timing function.  
Operating Mode  
Contact Output  
Timing Range(1)  
Input Voltage  
Cat. No.  
24V AC/DC  
1 N.O.  
0.05 s…10 hr (6 settings)  
0.05 s…10 hr (6 settings)  
0.05 s…10 hr (6 settings)  
0.05 s…10 hr (6 settings)  
0.05 s…10 hr (6 settings)  
0.05 s…10 hr (6 settings)  
0.05 s…10 hr (6 settings)  
0.05 s…10 hr (6 settings)  
0.05 s…10 hr (6 settings)  
0.05 s…10 hr (6 settings)  
700-FEA1TU22  
700-FEA3TU23  
700-FEB1TU22  
700-FEB3TU23  
700-FED1TU22  
700-FED3TU23  
700-FEE3TU23  
700-FEF1TU22  
700-FEF3TU23  
700-FEL3TU23  
110…240V AC 50/60 Hz(2)  
ON-delay  
24V…48V AC/DC  
24…240V AC 50/60 Hz  
SPDT (1 C/O)  
1 N.O.  
24V AC/DC  
110…240V AC 50/60 Hz(2)  
OFF-delay  
24V…48V AC/DC  
24…240V AC 50/60 Hz  
SPDT (1 C/O)  
1 N.O.  
24V AC/DC  
110…240V AC 50/60 Hz(2)  
One Shot  
24V…48V AC/DC  
24…240V AC 50/60 Hz  
SPDT (1 C/O)  
SPDT (1 C/O)  
1 N.O.  
24V…48V AC/DC  
24…240V AC 50/60 Hz  
Fleeting OFF-delay  
24V AC/DC  
110…240V AC 50/60 Hz(2)  
Flasher (repeat cycle  
starting with pulse)  
24V…48V AC/DC  
24…240V AC 50/60 Hz  
SPDT (1 C/O)  
SPDT (1 C/O)  
24V…48V AC/DC  
24…240V AC 50/60 Hz  
Pulse Converter  
(1) Time ranges: 0.05 s…1 s, 0.5…10 s, 0.05…1 min, 0.5…10 min, 0.05…1 hr, 0.5…10 hr.  
(2) Voltage is either 24V AC 50/60 Hz or 24V DC.  
Special Functions  
Operating Mode  
Contact Output  
Timing Range(1)  
Input Voltage  
Cat. No.  
24V…48V AC/DC  
24…240V AC 50/60 Hz  
Star-Delta  
2 N.O. with 1 Common  
0.15 s…10 min (4 settings)  
700-FEY2QU23  
(1) Time ranges: 0.15…3 s, 0.5…10 s, 3 s…1 min, 30 s…10 min.  
92  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Accessories - 700-FE Relays  
Description  
Pkg. Quantity  
Cat. No.  
199-FSA  
100-FMS  
Panel Mounting Adapter  
5
For surface mounting according to drilling plan EN 50 002  
Label Sheet 105 self-adhesive paper labels each, 6 x 17 mm  
10  
Function and Connection Diagrams - 700-FE Relays  
(A) On-Delay  
(B) Off-Delay  
A1/A2  
A1/A2  
A1/B1  
18  
15  
15  
18  
A1/A3  
U
S
U
S
15  
18  
A1 B1  
A2  
18  
t
Output  
15  
Output  
LED  
t
LED  
A2  
1 N.O. (SPST)  
1 N.O. (SPST)  
U
S
A1/A2  
A1/B1  
S
15  
18  
A1  
A2  
A1 B1  
15  
A1/A2  
U
Output  
LED  
18  
16  
t
15  
18  
15  
Output  
LED  
t
16  
16  
A2  
18 16  
1 C/O (SPDT)  
1 C/O (SPDT)  
(D) One Shot  
(F) Flasher (Repeat Cycle Starting with Pulse)  
15  
18  
A1  
A2  
A1/A2  
A1/A2  
A1  
15  
18  
U
U
Output  
LED  
18  
18  
Output  
15  
t
t
t
15  
t
t
t
LED  
A2  
1 N.O. (SPST)  
1 N.O. (SPST)  
15  
A1  
A2  
15  
A1/A2  
A1  
A2  
U
A1/A2  
U
Output  
LED  
18  
18  
Output  
15  
t
t
t
15  
16  
t
t
t
16  
LED  
18 16  
18 16  
1 C/O (SPDT)  
1 C/O (SPDT)  
(E) Fleeting Off-Delay  
(L) Pulse Converter  
1)  
1)  
S
A1/A2  
B1  
S
A1/A2  
A1/B1  
U
S
15  
A1 B1  
A2  
15  
A1  
A2  
B1  
t
18  
LED  
15  
18 16  
Output  
LED  
t
t
16  
18 16  
1 C/O (SPDT)  
(Y) Star-Delta Timing Relay  
A1/A2  
U
A1  
A2  
17  
17/18  
t
17/28  
tu = 50...65 ms  
18  
28  
LED  
Bi-color light-emitting diode: 1 C/O (SPDT) or 1 N.O. Contact Timers  
Single Color light-emitting diode: 2 N.O. with Common  
LED U = green: Supply voltage available.  
LED Relay = red: Output is energized.  
ON = green  
OFF = red  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
93  
Relay and Timer Specifications  
(1)  
Specifications - 700-FE Relays  
Attribute  
700-FE  
1 N.O.  
SPDT  
Setting Accuracy  
Repeatability  
5% of full scale  
1% of setting (typical)  
By voltage: 0.01%/%  
Δ
U
By voltage: 0.001%/%ΔU  
Tolerance  
By temperature: 0.25%/°C  
By temperature: 0.025%/°C  
Supply  
Supply Voltage  
24V AC/DC(1) and 110…240V AC, 50/60 Hz  
24…48V DC and 24…240V AC, 50/60 Hz  
AC  
–15%/+10%  
–15%/+20%  
VoltageTolerance  
DC  
Power Consumption  
TimeEnergized  
0.5 W at 24V DC, 5VA at 240V AC  
100%  
ResetTime  
100 ms  
Cable Length (Supply Voltage Control)  
Max. 250 m (750 feet)  
PulseControl(B1)  
250 ms  
Impulse Duration  
Input Voltage  
Input Current  
50 ms (AC), 30 ms (DC)  
supply voltage range  
1 mA  
Max.250mwithoutparallelloadbetweenB1andA2  
Max. 50 m with load (< 3 k between B1 and A2  
Cable Length  
Ω
Outputs  
1 N.O. contact  
Contact Type  
1 Form C – SPDT contact  
Dielectric Withstand  
Contact-to-coil  
Voltage  
4000V  
Power  
1250VA  
AC-1  
AC-14  
DC-13  
5 A /250V AC (resistive load)  
1 A/250V AC (inductive load)  
1 A/24V DC (inductive load)  
According to IEC 947-  
5-1  
Switching Capacity  
According to UL 508  
NEMA D300 - 1 A/300V AC  
Short circuit Resistance  
Life  
6 A gL (Fast Blow Fuse)  
20 million operations  
Mechanical  
Electrical  
0.4 million at 1 A/250V AC, resistive  
0.4 million at 0.5 A/250V AC, cos φ = 0.4  
0.4 million at 1 A/24V DC, resistive  
State Indicator  
Certifications  
Standards  
1 bicolor light-emitting diode (Supply; Relay)  
cULus Listed (File No. E14840, Guide NKCR/NKCR7), CE Marked  
EN/IEC 60947-1, EN/IEC 60947-5-1, UL 508, CSA 22.2 No. 14  
2 kV AC/50 Hz test voltage according to VDE 0435  
and 4 kV 1.2/50 μs surge voltage according to IEC 60947-1 between all inputs and outputs  
Insulation Characteristics  
The following requirements are fulfilled:  
Surge capacity of the supply voltage according to IEC 61000-4-5: Level 3  
Burst according to IEC 61000-4-4: Level 3  
EMC/Interference Immunity  
ESD discharge according to IEC 61000-4-2: Level 3  
EMC / Emission  
electromagnetic fields according to EN 55 022: Class B  
(1) Time Characteristics (according to VDE 0435, part 2021)  
94  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Attribute  
700-FE  
Safe Isolation  
according to VDE 0106 T 101  
56 cycles (24 hr) at 25…40 °C and 95% relative humidity according to IEC 60068-2-30  
4 g in three axes at 10…500 Hz, test FC according to IEC 60068-2-6  
50 g according to IEC 68-2-27  
Climatic Withstand  
Vibration Resistance  
Shock Resistance  
Enclosure: IP40  
Terminal: IP 20  
Protection Class IEC 60947-1  
Weight  
60 g  
60 g  
cULus, Germanischer Lloyd, CE Certified  
Certifications  
cULus, CE Certified  
Open: –25…+60 °C  
Enclosed: –25…+45°C  
Storage: –40…+85 °C  
Ambient Temperature  
Connections  
Screw terminal M3 for Pozidriv No.1, Philips, and slotted screws No.2. suitable for power screwdriver.  
Rated tightening torque 8.8 lb.-in. (max. 1.0 Nm)  
2
2
2
For terminal cross-sections of 1 x 0.5 mm …2 x 1.5 mm (solid) or 2 x 1.5 mm (stranded with sleeve), #20…14 AWG. Finger  
protection according to EN 50274  
Mounting  
For surface mounting in any position; snap-on mounting on 35 mm DIN Rail or by adapter and two screws (M4 type)  
Synthetic materials without dioxin according to EC/EFTA-Notification No. 93/0141/D electrical contacts are AgCdO  
Disposal  
(1) Voltage is either 24V DC or AC 50/60 Hz.  
Dimensions - 700-FE Relays  
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.  
13  
(0.51)  
22.5  
(0.89)  
43.0  
(1-11/16)  
75.0  
(2.95)  
80.0  
45.0  
4.3  
(0.17)  
35.0  
(1.38)  
(3-5/32)  
(1-25/32)  
58.0  
(2.28)  
17  
(0.67)  
12  
(0.47)  
66.0  
2.0  
(0.08)  
4.3  
(0.17)  
(2-9/16)  
17.5  
70.0  
(11/16)  
(2-49/64)  
9.0  
(0.35)  
5.5  
(0.22)  
Cat. No. 700-FE…  
Cat. No. 199-FSA…  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
95  
Relay and Timer Specifications  
700-FS High Performance Timing Relay  
Adjustable function and timing range timing relays  
DIN Rail mounted without cost of socket  
22.5 mm wide multi-function or single functions  
Available as SPDT or DPDT contact output, 8 A  
Timing Ranges From 0.05 s…60 hr  
Coil surge protection  
Hazardous location version available  
Catalog Number Explanation - 700-FS Relays  
700  
FS  
H
3
U
U23  
a
b
c
d
e
f
a
b
c
d
e
f
-
Bulletin  
Type of  
Relay  
Operating Mode  
Contact Output  
Timing Range  
Input Voltage  
Number  
A–0.05…1 s  
B–0.15…3 s  
C–0.5…10 s  
A–On-delay  
B–Off-delay  
C–On- and off-delay  
D–One shot  
D–1.5…30 s  
E–0.05…1 min  
F–0.15…3 min  
G–0.5…10 min  
H–1.5…30 min  
I–0.05…1 hr  
J–0.15…3 hr  
K–0.5…10 hr  
L–3.0…60 hr  
U–0.05 s…60 hr (1)  
E–Fleeting off-delay  
3–One changeover  
contact (SPDT)1 C/O  
Z12–12V DC  
U23–24…48V DC | 24…240V AC 50/60 Hz  
700  
FS  
F–Flasher (repeat cycle starts with pulse)  
G–Flasher (repeat cycle starts with pause)  
I–On-delay pulse generator  
J–On-delay (pulse controlled)  
K–One shot/watch dog (pulse controlled)  
L–Pulse converter  
(1) Valid for functions "A" and "B" only.  
Single Function (With 2PDT 2 C/O contacts)  
Operating Mode  
Contact Output  
Timing Range(1)  
Input Voltage  
12V DC  
Cat. No.  
On-delay  
(DPDT) 2 C/O  
700-FSA4UZ12  
24…48V DC  
On-delay  
Off-delay  
Off-delay  
(DPDT) 2 C/O  
(DPDT) 2 C/O  
(DPDT) 2 C/O  
700-FSA4UU23  
24…240V AC, 50/60 Hz  
0.05 s…60 hr  
12V DC  
700-FSB4UZ12  
700-FSB4UU23  
24…48V DC  
24…240V AC, 50/60 Hz  
(1) The time range of "0.05 s…60 hr" is selectable in 12 smaller ranges plus an ON and OFF function for maintenance needs.  
(1)  
Single Function With Hazardous Location Certification (With SPDT 1 C/O contacts)  
Operating Mode  
Contact Output  
Timing Range  
0.05 s…1 s  
Input Voltage  
Cat. No.  
24…48V DC  
24…240V AC  
50/60 Hz  
700-FSK3AU23-EX  
700-FSK3CU23-EX  
One Shot / Watch Dog  
(Pulse Controlled)  
(SPDT) 1 C/O  
0.5 s…10 s  
96  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Multi-Function  
This device allows the flexibility of selecting one of 8 single timing functions.  
Operating Mode  
Contact Output  
Timing Range  
Input Voltage  
Cat. No.  
(SPDT) 1 C/O  
12V DC  
700-FSM3UZ12  
24…48V DC  
24…240V AC  
50/60 Hz  
Multi-function timing relays  
(SPDT) 1 C/O  
(DPDT) 2 C/O  
(DPDT) 2 C/O  
700-FSM3UU23  
700-FSM4UZ12  
700-FSM4UU23  
8 Single-functions:  
A, B, C, D, E, F, I, and L  
0.05 s…60 hr  
ON and OFF function additional  
(for installation and maintenance)  
note: See connection diagrams for further description.  
12V DC  
24…48V DC  
24…240V AC  
50/60 Hz  
(1)  
Multi-Function With Hazardous Location Certification  
This device allows the flexibility of selecting one of 8 single timing functions.  
Operating Mode  
Contact Output  
Timing Range(1)  
Input Voltage  
Cat. No.  
M Multi-function timing relays  
8 Single-functions:  
(SPDT) 1 C/O  
700-FSM3UU23-EX  
24…48V DC  
24…240V AC  
50/60 Hz  
A, B, C, D, E, F, I, and L  
0.05 s…60 h  
ON and OFF function additional  
(for installation and maintenance)  
Note: See connection diagrams for further description.  
(DPDT) 2 C/O  
700-FSM4UU23-EX  
(1) The time range of "0.05 s…60 hr" is selectable in 12 smaller ranges plus an ON and OFF function for maintenance needs.  
Special Function  
Operating Mode  
Contact Output  
Timing Range  
Input Voltage  
Cat. No.  
12V DC  
700-FSH3UZ12  
0.05 s…60 hr (2)  
24…48V DC  
24…240V AC  
50/60 Hz  
700-FSH3UU23  
Flasher (repeat cycle starting with pulse or pause)  
(SPDT) 1 C/O  
12V DC  
700-FSH3VZ12  
700-FSH3VU23  
2 x 0.05 s…60 hr (2 ranges)  
0.15 s…10 min(3)  
24…48V DC  
24…240V AC, 50/60 Hz  
(SPDT) 1 C/O  
(DPDT) 2 C/O  
24…240V DC  
24…240V AC  
50/60 Hz  
700-FSQ3QU18  
700-FSQ4QU18  
700-FSY2CU23  
700-FSY2DU23  
700-FSY2EU23  
700-FSY2FU23  
700-FSY2GU23  
OFF-delay without supply voltages (True OFF-delay)(1)  
0.5 s…10 s  
1.5…30 s  
24…48V DC  
Star-Delta  
2 N.O. + 1 Common  
0.05 s…1 min  
0.15…3 min  
0.5…10 min  
24…240V AC  
50/60 Hz  
(1) Due to shock during shipment, the state of the contacts should be verified before initial use. Minimum power on time is 800 msec  
(2) The time range of "0.05 s…60 hr" is selectable in 12 smaller ranges plus an ON and OFF function for maintenance needs.  
(3) This time range is selectable in four smaller ranges: 0.15 s…2.5 s, 0.5 s…10 s, 4 s…80 s, 30 s…10 min.  
(1) Temp. Code T4A 2A 32VDC MAX.: II 3 G, EEx nL IIC T4 DEMKO 04 ATEX 0404974X 2A 32VDC MAX. Ta 70 °C  
Ind. Cont. Eq. for Hazardous Location Listed 87SL Class 1, Div. 2, Groups A,B,C,D Class 1, Zn 2, Group IIC  
Subject devices are to be installed in an ATEX Certified IP54 (as defined in IEC 60529) enclosure and accessible only by the use of a tool.  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
97  
Relay and Timer Specifications  
Multi-Function Timing Relay Function and Time Range Settings - 700-FS Relays  
Description  
SPDT  
DPDT  
Multi-function timing relays 700-FSM3U includes 10 setting functions:  
Multi-Time Setting Range 0.05 s…60 h  
(A)On-Delay  
(B)Off-Delay  
(1 s) 0.05…1 s  
(3 s) 0.15…3 s  
(10 s) 0.5…10 s  
(1 min) 0.05…1 min  
(3 min) 0.15…3 min  
(10 min) 0.5…10  
min  
(1 hr) 0.05…1 hr  
(3 hr) 0.15…3 hr  
(10 hr) 0.5…10 hr  
(60 hr) 3.…60 hr  
(C)On- and Off-Delay  
(D)One shot  
(E)Fleeting Off-Delay  
(F)Flasher (repeat cycle starts with pulse)  
(I)On-Delay pulse generator  
(L)Pulse converter  
(On)ON-Function (1)  
(Off)OFF-Function(1)  
Note: Switch is on DPDT relays only. When switch is down, one contact is instantaneous and one is timed.  
When switch is up, both contacts are timed.  
(1) For installation and maintenance.  
Accessories - 700-FS Relays  
Description  
Pkg. Quantity  
Cat. No.  
Setting Knob with Scale  
(for time setting without tools)  
10  
700-FSK  
Panel Mounting Adapter  
For surface mounting according to drilling plan EN 50 002  
5
199-FSA  
Label Sheet  
10  
100-FMS  
100-FMP  
105 self-adhesive paper labels each, 6 x 17 mm  
Marking Tag Sheet  
160 perforated paper labels each, 6 x 17 mm, to be used with a transparent 10  
cover  
Transparent Cover  
100  
100  
100-FMC  
To be used with marking tag sheets  
Marking Tag Adapters  
To be used with marking tag: System 1492 W  
(1)  
100-FMA2  
(1) Cat. No. 100-FMA2 is only a marking tag carrier. Please refer to the Terminal Block Accessories section, Marking Solutions of this publication for appropriate marker cards to be used with this carrier.  
IMPORTANT Versatile Mounting: The 700-FS timing relay can be panel or DIN rail mounted. For best long-term performance, allow at least  
5 mm (0.2 in.) of space on each side of the relay for proper ventilation.  
98  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Function and Connection Diagrams - 700-FS Relays  
(A) On-Delay  
(G) Flasher (Repeat Cycle Starts with Pause)  
Output  
(I) On-Delay Pulse Generator  
(B) Off-Delay (Min. Pulse AC 50 ms…DC 30 ms)  
Output  
LED  
(3)  
(J) On-Delay (Pulse Controlled)  
(1)  
Output  
LED  
(C) On- and Off-Delay  
(1)  
(K) One Shot/Watch Dog (Pulse Controlled)  
Output  
LED  
(3)  
(1)  
Output  
LED  
(D) One Shot  
(On) ON-Function (Off) OFF-Function  
Output  
(3)  
Output 1  
Output 2  
LED  
Output 1  
Output 2  
LED  
(E) Fleeting Off-Delay (Min. Pulse AC 50 ms…DC 30 ms)  
(L) Pulse Converter (Min. Pulse AC 50 ms…DC 30 ms)  
(1)  
Output  
LED  
t
(1)  
(3)  
Output  
LED  
(F) Flasher (Repeat Cycle Starts with Pulse)  
(3)  
Output  
Cleverly Designed Function Display light-emitting diode (Green)  
(3)  
Output in Rest Position, No Timing  
(1)  
Output in Rest Position, Time Running  
Output in Operation Position, No Time Running  
Output in Operation Position, Time Running  
(1) A voltage other than the supply voltage can be used at B1, but must be within voltages specified on timer.  
(2) Output 2 is selectable as instantaneous contact with sliding switch () on front panel (instantaneous when switch is down, timed when switch is up).  
(3) Available on multifunction "M," and single function "A" or "B" option timing relays along with code "4" (2PDT contacts).  
Bridge or potentiometer 10 kΩ, 0.25 W min. (low voltage) for external time setting. Set timer dial to 0.0.  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
99  
Relay and Timer Specifications  
Special Function Flasher Timing Relay  
Description  
t
Setting  
Switch  
2
Up  
Supply Voltages (A1/A2)  
Z12 12V DC  
U23 24…48V DC, 24…240V AC, 50/60 Hz  
Down  
1 Range Setting  
Seperate Range  
Settings  
t
Setting  
1
700-FSH3U  
700-FSH3V  
Function Diagram / Connection Diagram(1)  
(H) Flasher (Repeat Cycle Starting with Pulse or Pause)  
The repeat cycle timer permits different settings for on and off times. The following operating modes are possible:  
Oscillating mode; repeat cycle starts with voltage that is applied at A1 and B1, and continues to repeat until voltage is off.  
One cycle mode; started by energizing B1 with voltage on A1 and A2.  
Output starts with pulse or pause (switch Up or Down).  
700-FSH3U provides (1) range setting for t and t  
1
2
700-FSH3V provides (2) range settings for t and t  
1
2
Supply Voltage Controlled, Oscillating Mode Starting with Pause  
— Switch Is up  
Supply Voltage Controlled, Oscillating Mode Starting with Pulse  
— Switch is Down  
A1/A2  
A1/B1  
U
S
A1/A2  
A1/B1  
U
S
15  
B1  
A1  
B1  
15  
A1  
A2  
t2  
t2  
t1  
t1  
18  
t1  
t1  
18  
t2  
t2  
15  
15  
Output  
LED  
Output  
LED  
16  
16  
A2  
18 16  
18  
16  
Pulse Controlled, Output Starts With Pause (Min. Pulse AC 50 ms  
Pulse Controlled, Output Starts with Pulse (Min. Pulse AC 50 ms  
— DC 30 ms) — Switch is Up One Cycle Mode  
— DC 30 ms) — Switch is Down One Cycle Mode  
— Voltage Supplied at A1 and A2, then Pulsing “s” to Energize B1 will  
Initiate One Cycle.  
— Voltage Supplied at A1 and A2, then Pulsing “s” to Energize B1 will  
Initiate One Cycle.  
A1/A2  
U
S
U
S
A1/A2  
S
B1  
s
B1  
15  
A1  
A2  
A1  
A2  
15  
A1/B1  
18  
A1/B1  
t2  
t1  
18  
15  
t1  
t1  
t2  
t1  
t2  
t2  
15  
16  
Output  
LED  
Output  
LED  
16  
18 16  
18 16  
(1) If B1 is pulsed, a one full time cycle consisting of t1 and t2 is completed.  
LED Operation Chart Ñ Green LED  
LED  
LED  
LED  
LED  
Output at Shelf State, No Timing - LED OFF  
Output at Shelf State, Time is Running - LED Flashing  
Output NO Contact is Closed, No Timing - LED On  
Output NO Contact is Closed, Time is Running - LED Long Flashing  
100  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Function Diagram / Connection Diagram(1)  
(Q) Off-Delay without Supply Voltage (True Off-Delay)  
When input power is turned on, the output contact changes state. When the power is removed, the time delay begins. The output contact returns to shelf state at the end of the  
time delay.  
tp  
tp  
U
A1/A2  
U
A1/A2  
18  
16  
15  
25  
A1  
A2  
A1  
A2  
15  
t
t
t
18  
15  
15  
Output 1  
Output  
LED  
16  
28  
25  
Output 2  
LED  
26  
18 16  
28 26  
16  
18  
(Y) Star-Delta Timing Relay  
When power is applied, the output contact 17/18(Y) changes state. After the time setting, the output contact 17/18(Y) returns to shelf state. After the fixed time (50… 60 ms),  
the output contact 17/28Δ changes state. Both output contacts return to shelf state whenever the power is removed.  
A1/A2  
17/18  
17/28  
U
A1  
17  
t
tu = 50...65 ms  
A2  
28  
18  
LED  
(1) Min. pulse (tp) required: 800 ms  
(1)  
Input Current  
1 mA  
Specifications - 700-FS Relays  
Max. Leakage Current  
Cable Length  
400 micro Amps  
Attribute  
Value  
Max. 250 m (800 ft) without parallel load between B1 and A2,  
Setting Accuracy  
Repeatability  
5% of full scale  
M a x . 5 0 m ( 1 6 0 f t ) w i t h l o a d ( < 3 k Ω) betweenB1andA2  
0.2% of the setting values  
Voltage: 0.001%/%  
Outputs  
ΔU  
Tolerance  
Temperature: 0.025%/°C  
Contact Type  
Relay as changeover switch  
5000 V  
Dielectric Coil to Contact  
Supply  
Voltage: 440V AC  
Current Ith (AC-1): 8 A (5 A for 700- FSQ)  
Power: 2000 VA  
Attribute  
Value  
Supply Voltages  
VoltageTolerance  
Power Consumption  
TimeEnergized  
ResetTime  
24…48V DC and 24…240V AC, 50/60 Hz (multi voltage)  
–20…+20%(DC), –15…+10% (AC)  
0.5 W at 24V DC, 5 VA at 240V AC  
100%  
According to IEC 947-5-1:  
3 A/440V AC (inductive load, AC 14)  
3 A/250V AC (inductive load, AC 15)  
1 A/24V DC (inductive load, DC 13)  
According to UL 508:  
Switching Capacity  
50 ms  
Voltage Interruption  
Input Impedance  
20 ms without reset (supply voltage)  
Relay ON: 3K-13K ohms, Relay OFF: 0.7K-4K ohms  
1.5 A/250V AC (B300)  
3 A/120V AC (B300)  
Short-Circuit Resistance  
10 A gL  
Cable Length (Supply  
Voltage Control)  
Max. 250 m (800 ft)  
Pulse Control (B1)  
Attribute  
Value  
Pulse Duration  
Input Voltage  
50 ms (AC), 30 ms (DC)  
Supply voltage range  
(1) Time Characteristics (according to VDE 0435, Part 2021)  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
101  
Relay and Timer Specifications  
Mechanical: 30 million operations  
Electrical operations:  
4 mil at 1 A/250V AC, cos φ = 1  
0.2 mil at 6 A/250V AC, cos φ = 1  
1.5 mil at 1 A/250V AC, cos φ = 0.3  
0.3 mil at 3 A/250V AC, cos φ = 0.3  
0.5 mil at 6 A/24V DC, resistive  
2 mil at 4 A/24V DC, resistive  
Life  
2 mil at 0.2 A/230V DC, resistive  
1 mil at 0.4 A/24V DC, L/R = 20 ms  
1 mil at 0.2 A/110V DC, L/R = 20 ms  
1 mil at 0.1 A/230V DC, L/R = 20 ms  
1 LED, combination signal  
State Indicator  
General Data- 700-FS Relays  
2 kVAC/50 Hz test voltage according to VDE 0435 and 6 kV 1.2/50 μs surge voltage according to IEC 947-1 between all inputs and outputs  
Insulation Characteristics  
Performance of following requirements:  
Surge capacity of the supply voltage according to IEC 1000-4-5: 4 kV 1.2/50 μs  
Burst according to IEC 1000-4-4: 6 kV 6/50 ns  
EMC/Interference Immunity  
ESD discharge according to IEC 1000- 4-2:  
Contact 8 kV, air 8 kV  
Electromagnetic HF field according to IEC 801-3 and conducted electromagnetic HF signal according to IEC 801-6: Level 3  
Electromagnetic fields according to EN 55 022: class B  
According to VDE 106, part 101  
EMC/Emission  
Safe Isolation  
56 Cycles (24 hr) at 25…40 °C and 95% relative humidity according to IEC 68-2-30 and  
IEC 68-2-3  
Climatic Withstand  
4 g in three axes at 10…500 Hz, test FC according to IEC 68-2-6  
50 g according to IEC 68-2-27  
Vibration Resistance  
Shock Resistance  
Enclosure: IP40  
IP 30 (Single-function)  
Terminal: IP 20 according to IEC 947-1  
Protection Class  
100 g  
Weight  
Approval  
UL, C-UL  
Open: –25…+60 °C  
Enclosed: –25…+45 °C  
Storage: –40…+85 °C  
Ambient Temperature  
Terminals  
Screw terminal M3.5 for Number 2 Posidriv, Philips, and slotted screws. Suitable for power screwdriver. Rated tightening torque 8.8 lb.-in. (0.8 N•m,  
max. 1.2 N•m).  
2
2
2
Dual-chamber system for terminal cross-sections of 1 x 0.5 mm …2 x 2.5 mm (solid) or stranded 2 x 2.5 mm (flexible with sleeve), #20…14 AWG.  
Finger protection according to VDE 0106.  
Mounting  
Disposal  
Front mounting; For snap-on mounting on 35 mm DIN Rail or screw fixing by adapter and 2 screws (M4 type)  
Synthetic material without dioxin according to EC/EFTA notification Number 93/0141/D electrical contacts with cadmium  
cULus Listed (File No. E14840, Guide NKCR/NKCR7),CE Marked  
Certifications  
Standards  
EN/IEC 60947-1, EN/IEC 60947-5-1, UL 508, CSA 22.2 No. 14  
Temp. Code T4A  
2A 32VDC MAX.  
Mounting: Product shall be installed in an enclosure constructed in accordance with the requirements of EN50021.  
102  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
700-HNC Miniature Timing Relay  
Miniature timer, perfect for converting 700-HC "Ice Cube" relays into timing relays  
4 operating modes  
4PDT contact output  
Timing range from 0.1 s…10 hr  
Socket mounted  
Model  
Timing Mode  
Contact Output  
Input Voltages  
Timing Range  
0.1 s…10 min  
.1 min…10 hr  
0.1 s…10 min  
0.1 min.…10 hr  
0.1 s…10 min  
0.1 min.…10 hr  
0.1 s…10 min  
0.1 min.…10 hr  
0.1 s…10 min  
0.1 min.…10 hr  
0.1 s…10 min  
0.1 min.…10 hr  
0.1 s…10 min  
0.1 min.…10 hr  
0.1 s…10 min  
0.1 min.…10 hr  
Socket Type  
Cat. No.  
700-HNC44AZ12  
700-HNC44BZ12  
700-HNC44AZ24  
700-HNC44BZ24  
700-HNC44AZ48  
700-HNC44BZ48  
700-HNC44AZ11  
700-HNC44BZ11  
700-HNC44AZ25  
700-HNC44BZ25  
700-HNC44AA24  
700-HNC44BA24  
700-HNC44AA12  
700-HNC44BA12  
700-HNC44AA23  
700-HNC44BA23  
12V DC  
24V DC  
48V DC  
On-Delay  
One Shot  
Repeat cycle, OFF-start  
Repeat cycle, ON-start  
100…110V DC  
125V DC  
700-HN103  
700-HN128  
4PDT  
24V AC  
100…120V AC  
200…230V AC  
Cat. No. 700-HNC  
Accessories - 700-HNC Relays  
Photo  
Description  
Pkg. Quantity  
Cat. No.  
Screw Terminal Socket — Panel or DIN Rail Mounting.  
Guarded Terminal Construction  
10  
10  
700-HN103  
700-HN128  
14-Blade miniature socket for use with 700-HNC timers.  
Screw Terminal Base Sockets — Panel or DIN Rail Mounting.  
Open Style Construction  
14-blade miniature socket for use with 700-HNC timers.  
Screw Terminal Socket – Panel or DIN Rail Mounting. Guarded Terminal  
Construction 14-blade miniature socket for use with 700-HNC timers. This socket has coil 10  
700-HN104  
700-HN263  
and contact separation.  
Retainer Clip for Cat. Nos. 700-HN103, -HN104 and -HN128 Sockets with 700-HNC Timers.  
Secures Timer in Socket.  
10  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
103  
Relay and Timer Specifications  
Specifications - 700-HNC Relays  
Attribute  
Pilot Duty Rating  
700-HNC  
NEMA B300  
Pin type  
Plug-in  
Operating voltage range  
Reset voltage  
85%…110% of rated supply voltage (12V DC: 90%…110% of rated supply voltage) (1)  
10% min. of rated supply voltage  
Relay ON:  
Relay OFF:  
1.5 VA(1.1 W) (at 24V AC, 60 Hz)  
0.2 VA(0.1 W) (at 24V AC, 60 Hz)  
24VAC:  
100…120VAC:  
200…230VAC:  
12VDC:  
Relay ON:  
Relay OFF:  
1.5 VA(1.3 W) (at 120V AC, 60 Hz)  
0.8 VA(0.5 W) (at 120V AC, 60 Hz)  
Relay ON:  
Relay OFF:  
1.8 VA(1.5 W) (at 230V AC, 60 Hz)  
1.2 VA(0.9 W) (at 230V AC, 60 Hz)  
Relay ON:  
Relay OFF:  
0.9 W (at 12V DC)  
0.07 W (at 12V DC)  
Power consumption  
Relay ON:  
Relay OFF:  
0.9 W (at 24V DC)  
0.07 W (at 24V DC)  
24VDC:  
Relay ON:  
Relay OFF:  
1.0 W (at 48V DC)  
0.2 W (at 48V DC)  
48VDC:  
Relay ON:  
Relay OFF:  
1.3 W (at 110V DC)  
0.3 W (at 110V DC)  
100…110VDC:  
125VDC:  
Relay ON:  
Relay OFF:  
1.3 W (at 125V DC)  
0.3 W (at 125V DC)  
Controloutputs  
4PDT: 5 A at 250V AC, resistive load (cos φ = 1)  
Characteristics  
120VAC  
Make  
30 A  
240VAC  
15 A  
120VAC  
Break  
3 A  
240VAC  
1.5 A  
Hp at 120V AC  
1/6Hp  
1/6Hp  
Hp at 240V AC  
Accuracy of operating time  
Setting error  
1% FS max. (1 s range: 1% 10 ms max.)  
10% 50 ms FS max.  
Reset time  
Min. power-opening time: 0.1 s max. (including halfway reset)  
2% FS max.  
Influence of voltage  
Influence of temperature  
Insulation resistance  
2% FS max.  
100 mΩ min. (at 500V DC)  
2000V AC, 50/60 Hz for 1 min (between current-carrying(t2e)rminals and exposed non-current-carrying metal parts)  
2000V AC, 50/60 Hz for 1 min (between operating power circuit and control output)  
2000V AC, 50/60 Hz for 1 min (between different pole contacts; 2-pole model)  
1500V AC, 50/60 Hz for 1 min (between different pole contacts; 4-pole model)  
1000V AC, 50/60 Hz for 1 min (between non-continuous contacts)  
Malfunction: 10…55 Hz, 0.5 mm single amplitude  
Dielectric strength  
Vibration resistance  
Shock resistance  
2
Malfunction: 100 m/s (approx. 10G)  
Operating: -10 °C…50 °C (with no icing)  
Storage: -25 °C…65 °C (with no icing)  
Ambient temperature  
104  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Attribute  
700-HNC  
Ambient humidity  
Life expectancy  
Operating: 35%…85%  
Mechanical: 10 000 000 operations min. (under no load at 1800 operations/hr)  
Electrical: 4PDT: 200 000 operations min. (3 A at 250V AC, resistive load at 1800 operations/hr)  
1.5 kV, square-wave noise by noise simulator (pulse width: 100 ns / 1 μs, 1- ns rise)  
Noise immunity  
Static immunity  
Enclosure rating  
Weight  
Destruction:8 kV Malfunction:4 kV  
IP40  
Approx. 50 g  
Emission Enclosure:EN55011 Group 1 class A  
Emission AC Mains:EN55011 Group 1 class A  
Immunity ESD:EN61000-4-2:4 kV contact discharge (level 2) 8 kV air discharge (level 3)  
EMC  
Immunity RF-interference:ENV50140:10 V/m (amplitude modulated, 80 MHz to 1 GHz) (level 3) 10 V/m (pulse  
modulated, 900 MHz)  
Immunity Conducted Disturbance:ENV50141:10 V (0.15…80 MHz) (level 3)  
Immunity Burst:EN61000-4-4:2 kV power-line (level 3) 2 kV I/O signal-line (level 4)  
UL 508, CSA 22.2 No. 14, EN/IEC 61812-1  
Standards  
Certifications  
cURus Recognized (File No. E14843, Guide NRNT2/NRNT8), CSA Certified (File 224268), CE Marked, C- Tick Marked  
(1) Single-phase, full-wave-rectified power supplies can be used.  
(2) When using the 700-HNC continuously in any place where the ambient temperature is in a range of 45 °C…50 °C, supply 90%…110% of the rated supply voltages supply 95%…110% with 12V DC type).  
General Timer Functions  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
105  
Relay and Timer Specifications  
Timing Charts - 700-HNC Relays  
IMPORTANT t: Set time, Rt:Reset time  
Operating Mode  
Timing Charts / Wiring Diagram  
Rt  
t
t
ON-Delay  
Power (13-14)  
Time limit contact  
NC (9-1, 10-2, 11-3, 12-4)  
Power  
Time limit contact  
NO (9-5, 10-6, 11-7, 12-8)  
t
Output  
Run / Power Indicator (PW)  
Output Indicator (UP)  
One shot  
Power  
Power (13-14)  
Time limit contact  
NC (9-1, 10-2, 11-3, 12-4)  
Time limit contact  
NO (9-5, 10-6, 11-7, 12-8)  
Output  
Run / Power Indicator (PW)  
Output Indicator (UP)  
t
t
t
t
Timer  
Circuit  
Power (13-14)  
Repeat Cycle OFF-Start  
Time limit contact  
NC (9-1, 10-2, 11-3, 12-4)  
Power  
Time limit contact  
NO (9-5, 10-6, 11-7, 12-8)  
t
t
t
UP PW  
Output  
Run / Power Indicator (PW)  
Output Indicator (UP)  
t
t
t
t
Power (13-14)  
Repeat Cycle ON-Start  
Time limit contact  
NC (9-1, 10-2, 11-3, 12-4)  
Time limit contact  
NO (9-5, 10-6, 11-7, 12-8)  
Power  
t
t
t
Output  
Run / Power Indicator (PW)  
Output Indicator (UP)  
General Timer Functions  
Pulse Operation  
A pulse output for a certain period can be obtained with a random external input signal. Use the 700-HNC  
timing relay in interval mode as shown in the following timing charts.  
Output Indicator (Orange)  
(Lit: Output ON)  
Run/Power Indicator  
(Green)  
(Lit: Power ON)  
1
5
3
7
4
8
2
6
Power (9-14)  
Main Dial  
External short circuit  
(5-13)  
External input  
(9-13)  
Set the desired time  
according to time range  
selectable by DIP switch.  
50 ms  
min.  
Time limit contact NO  
(10-6, 11-7, 12-8)  
Time limit contact NC  
(10-2, 11-3, 12-4)  
Run/Power indicator  
(PW)  
Output indicator (UP)  
9
11  
12  
14  
10  
13  
Timer  
Circuit  
(—)  
( )  
+
( )  
~
(
~
)
UP FW  
External Input  
~
Note: t: Set time  
(
)
Rt: Reset time  
106  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
DIP Switch Settings - 700-HNC Relays  
Time Ranges  
Cat. No.  
Time Range  
Time Setting Range  
Setting  
Factory-Set  
700-HNC44AZ12  
700-HNC44AZ24  
700-HNC44AZ48  
700-HNC44AZ11  
700-HNC44AZ25  
700-HNC44AA24  
700-HNC44AA12  
700-HNC44AA23  
1 s  
10 s  
0.1 s…1 s  
Yes  
1 s…10 s  
0.1 s…1 min  
1…10 min  
0.1…1 min  
1…10 min  
0.1…1 hr  
No  
No  
No  
Yes  
No  
No  
No  
1 min  
10 min  
1 min  
10 min  
1 hr  
700-HNC44BZ12  
700-HNC44BZ24  
700-HNC44BZ48  
700-HNC44BZ11  
700-HNC44BZ25  
700-HNC44BA24  
700-HNC44BA12  
700-HNC44BA23  
1 hr  
1…10 hr  
Note: The top two DIP switch pins are used to select the time ranges.  
Operating Mode  
Setting  
Factory-set  
ON-delay  
Yes  
No  
No  
No  
One Shot  
Repeat Cycle OFF-start  
Repeat Cycle ON-start  
Note: The top two DIP switch pins are used to select the time ranges.  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
107  
Relay and Timer Specifications  
Dimensions - 700-HNC Relays  
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.  
30.0  
24.9  
(57/64)  
21.1  
(1-3/16)  
6.1 (15/64)  
(53/64)  
5
1
8
4
6
2
7
3
Fourteen 3 x 1.2 mm  
Elliptic Holes  
4.2  
(5/32)  
62.0  
(2-15/64)  
28  
(1.10)  
6.3  
65.0  
(2-9/16)  
14  
12  
13  
9
(.024)  
4.0  
(0.15)  
6.4  
(0.25)  
52.6  
10  
11  
21.5 max  
(084)  
(2.07)  
63.0  
(2.48)  
26.0  
(1-1/64)  
Cat. No. 700-HNC…  
Cat. No. 700-HN128 (1)  
Wire Size: 2 x 1.5 mm (#2-16 AWG…#1-20 AWG)  
(Either Solid or Stranded)  
Strip Length: 9 mm (3/8 in.) - Torque: 0.8 N•m (7 lb•in)  
2
27.0  
(1.06)  
60.9  
(2.40)  
Panel Mounting  
21.5  
(0.85)  
28.9  
(1-9/64)  
24.5  
(31/32)  
76.0  
(2.99)  
35.6  
(1.40)  
67.0  
(2-5/8)  
3.2  
(0.13)  
18.9  
(0.74)  
34.9  
(1.37)  
32.0  
(1.26)  
35.5  
(1.40)  
#4-40  
M3  
30.0  
(1-11/64)  
2.5  
(0.10)  
Cat. No. 700-HN103  
Cat. No. 700-HN104  
2
2
Single wire: 0.2…2.5 mm (#24 AWG…14 AWG)  
Single Wire: 0.2…2.5 mm ( #24 AWG…14 AWG)  
2
2
2
2
Double wire: 2 x 0.2 mm …2 x 1.5 mm (2 x 24 AWG…2 x 16 AWG)  
Wire type: solid or stranded, copper only  
Double Wire: 2 x 0.2 mm …2 x2.5 mm (2 x 24 AWG…2 x 14 AWG)  
Wire Type: solid or stranded, copper only  
Strip length: 8 mm (5/16 in.), Torque: 0.5 N•m (4.4 lb•in)  
Strip Length: 7 mm (9/32 in.), Torque: 0.5 N•m (4.4 lb•in)  
(1) Total height of 700-HN128 + 700-HNC is 82.5 mm.  
108  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
700-HNK Ultra-Slim Timing Relay  
The ultra-slim timing relay is the smallest relay available  
It is perfect for converting 700-HK relays into a timing relay  
SPDT and DPST-NO contact output  
Socket-mounted  
Timing range From 0.1 s…10 hr  
Photo  
Timing Mode  
Socket Type  
Contact Output  
Timing Range  
Input Voltage  
12V DC  
24V DC  
24V AC  
Cat. No.  
700-HNK41AZ12  
700-HNK41AZ24  
700-HNK41AA24  
700-HNK41BZ12  
700-HNK41BZ24  
700-HNK41BA24  
700-HNK42AZ12  
700-HNK42AZ24  
700-HNK42AA24  
700-HNK42BZ12  
700-HNK42BZ24  
700-HNK42BA24  
0.1 s…10 min  
700-HN121  
SPDT (1)  
12V DC  
24V DC  
24V AC  
0.1 min…10 hr  
0.1 s…10 min  
0.1 min…10 hr  
On-Delay  
One Shot  
Repeat Cycle, OFF-start  
Repeat Cycle, ON-start  
12V DC  
24V DC  
24V AC  
700-HN122  
DPST-NO(2)  
12V DC  
24V DC  
24V AC  
(1) 5-blade terminal type only.  
(2) 8-blade terminal type only.  
Accessories - 700-HNK Relays  
Description  
Pkg. Quantity  
Cat. No.  
Screw Terminal Socket — Panel or DIN Rail Mounting  
5-blade miniatue socket. For use with 1-pole type 700-HNK41 timers. Socket includes a retainer clip.  
10  
700-HN121  
Screw Terminal Socket — Panel or DIN Rail Mounting  
8-blade miniature socket for use with 2-pole, 700-HNK42 timers. This socket includes a retainer clip.  
10  
700-HN122  
Sockets and Retainer Clip Reference  
Timer Type  
Socket Cat. No.  
700-HN121  
Retainer Clip Cat. No.  
Provided  
700-HNK  
700-HN122  
Provided  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
109  
Relay and Timer Specifications  
Specifications - 700-HNK Relays  
Attribute  
Pilot Duty Rating  
700-HNK  
NEMA B300  
Rated Supply Voltage  
Pin Type  
24V AC; 12, 24V DC  
Plug-in  
Operating Mode  
ON-delay, One Shot, Repeat Cycle OFF start, or Repeat Cycle ON start selectable with DIP switch.  
85%…110% of rated supply voltage (12 VDC: 90%…110% of rated supply voltage) (1)  
Operating Voltage Range  
24V AC:Relay ON:approx. 0.8 VA (at 24 VAC, 60 Hz) Relay OFF:0.5 VA (at 24V AC, 60 Hz)  
12V DC:Relay ON:approx. 0.4 W (at 12V DC) Relay OFF:0.1 W (at 12V DC)  
24V DC:Relay ON:approx. 0.5 W (at 24V DC) Relay OFF:0.2 W (at 24V DC)  
Power Consumption  
5 A at 250V AC, resistive load (cos φ = 1)  
The minimum applicable load is 10 mA at 5 VDC (P reference value).  
Control Outputs  
Characteristics  
120V AC  
Make  
30 A  
240V AC  
15 A  
120V AC  
Break  
3 A  
240V AC  
1.5 A  
1/6 Hp  
Hp at 240V AC  
Accuracy of Operating Time  
Setting Error  
1% FS max. (1 s range: +1% 10 ms max.)  
15% +50 ms FS max.  
12, 24V DC: 0.1 s max. (including halfway reset)  
Min. power-opening time:  
Reset Time  
24V AC: 0.5 s max. (including halfway reset)  
Influence of Voltage  
2% FS max.  
2% FS max.  
Influence of Temperature  
Insulation Resistance  
100 mΩmin.(at500VDC)  
2000V AC, 50/60 Hz for 1 min (between operating circuit and control output, or contacts of different poles)  
1000V AC, 50/60 Hz for 1 min (between non-continuous contacts)  
Dielectric Strength  
Vibration Resistance  
Shock Resistance  
Malfunction: 10…55 Hz, 0.5 mm single amplitude  
2
Malfunction: 100 m/s (approx. 10G)  
Operating: -10 °C…50 °C (with no icing)  
Storage: -25 °C…65 °C (with no icing)  
Ambient Temperature  
Ambient Humidity  
Life Expectancy  
Operating: 35…85%  
Mechanical: 10 000 000 operations min. (under no load at 1800 operations/hr)  
Electrical: 100 000 operations min. (3 A at 250V AC, resistive load at 1800 operations/hr)  
Impulse Withstand Voltage  
Noise Immunity  
Between power terminals: 1 kV  
1.5 kV, square-wave noise by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise)  
Destruction: 8 kV  
Malfunction: 4 kV  
Static Immunity  
Enclosure Rating  
Weight  
IP20  
Approx. 18 g  
110  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Attribute  
700-HNK  
Emission Enclosure: EN55011 Group 1 class A  
Emission AC Mains: EN55011 Group 1 class A  
Immunity ESD: EN61000-4-2:4 kV contact discharge (level 2) 8 kV air discharge (level 3)  
EMC  
Immunity RF-interference: ENV50140: 10 V/m (amplitude modulated, 80 MHz…1GHz) (level 3) 10 V/m (pulse  
modulated, 900 MHz)  
Immunity Conducted Disturbance: ENV50141:10 V (0.15…80 MHz) (level 3)  
Immunity Burst: EN61000-4-4:2 kV power-line (level 3) 2 kV I/O signal-line (level 4)  
Standards  
UL508, CSA C22.2 No. 14, EN/IEC 60947-5-1, EN/IEC 61812-1  
Certifications  
cURus Recognized Component (File No. E14843, Guide NRNTZ/NRNT8), CE Marked, C-Tick Marked  
(1) When using 700-HNK timer in any place where the ambient temperature is more than 50 °C, supply 90…110% of the rated voltages (12V DC: 95…11% of the rated voltage).  
IMPORTANT t: Set time, Rt:Reset time  
General Timer Functions  
Run/Power Indicator (Green)  
(Lit: Power ON)  
Main Dial  
Set the desired time according to time  
range selectable by DIP switch.  
Output Indicator (Orange)  
(Lit: Output ON)  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
111  
Relay and Timer Specifications  
Operating Mode  
Timing Charts / Wiring Diagram  
700-HNK41…  
700-HNK42…  
Rt  
t
t
Rt  
t
t
ON-Delay  
Power (1-5)  
Power (1-8)  
Time limit contact  
NC (4-2)  
Time limit contact  
NO 4-3, 5-6  
Power  
t
Time limit contact  
NO (4-3)  
Run/Power  
indicator (PW)  
Output  
Run/ Power  
Output indicator  
(OUT)  
Indicator (PW)  
Output Indicator  
(OUT)  
Rt  
Power (1-5)  
t
t
One shot  
Power  
Power (1-8)  
Time limit contact  
NC (4-2)  
Time limit contact  
NO (4-3, 5-6)  
Time limit contact  
NO (4-3)  
Run/Power  
indicator (PW)  
Output  
Run/ Power  
Output indicator  
(OUT)  
Indicator (PW)  
Output Indicator  
(OUT)  
t
t
t
t
Power (1-5)  
t
t
t
t
Repeat Cycle OFF-Start  
Time limit contact  
NC (4-2)  
Power (1-8)  
Time limit contact  
NO (4-3, 5-6)  
Power  
Time limit contact  
NO (4-3)  
t
t
t
Run/Power  
indicator (PW)  
Run/ Power  
Output  
Output indicator  
(OUT)  
Indicator (PW)  
Output Indicator  
(OUT)  
t
t
t
t
Power (1-5)  
t
t
t
t
Repeat Cycle ON-Start  
Power (1-8)  
Time limit contact  
NC (4-2)  
Time limit contact  
NO (4-3, 5-6)  
Power  
Time limit contact  
NO (4-3)  
t
t
t
Run/Power  
indicator (PW)  
Output  
Run/ Power  
Output indicator  
(OUT)  
Indicator (PW)  
Output Indicator  
(OUT)  
112  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Wiring- 700-HNK Relays  
3
4
5
6
4
2
3
1
Timer  
Circuit  
Timer  
Circuit  
8
5
1
(
(
)
(
)
(
)
(
)
)
~)  
( ~ )  
( ~ )  
(
~
OUT  
PW  
PW  
OUT  
Cat. No. 700-HNK42...  
Cat. No. 700-HNK41...  
A pulse output for a certain period can be obtained with a random external input signal. Use the 700-HNK in interval mode as shown in the following timing chart.  
5
4
Rt  
Rt  
t
t
t
Power (3-8)  
External Short Circuit (1-4)  
External Input (1-3)  
3
1
6
50 ms  
min.  
8
Timer  
Circuit  
(
)
)
(
(
)
)
(
~
Time Limit Contact NO (6-5)  
~
OUT  
PW  
Run/Power Indicator (PW)  
Output Indicator (OUT)  
External Input  
~
(
)
Note:t:Set time  
Rt: Reset time  
Mode  
Terminals  
Power supply between 3 and 8  
Short-circuit between 4 and 1  
Input signal between 3 and 1  
Pulse Operation  
Operating mode; One shot and all other modes  
Power supply between 1 and 8  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
113  
Relay and Timer Specifications  
Time Ranges- 700-HNK Relays  
Cat. No.  
Time Range  
Time Setting Range  
Setting  
Factory-Set  
1 s  
0.1…1 s  
Yes  
700-HNK41AZ12  
700-HNK41AZ24  
700-HNK41AA24  
700-HNK42AZ12  
700-HNK42AZ24  
700-HNK42AA24  
10 s  
1…10 s  
0.1 s…1 min  
1…10 min  
0.1…1 min  
1…10 min  
0.1…1 hr  
No  
No  
No  
Yes  
No  
No  
No  
1 min  
10 min  
1 min  
10 min  
1 hr  
700-HNK41BZ12  
700-HNK41BZ24  
700-HNK41BA24  
700-HNK42BZ12  
700-HNK42BZ24  
700-HNK42BA24  
10 hr  
1…10 hr  
Note: The left two DIP switch pins are used to select the time ranges.  
Operating Modes - 700-HNK Relays  
Operating Mode  
Setting  
Factory-set  
On-delay  
One Shot  
Yes  
No  
No  
No  
Repeat Cycle Off-start  
Repeat Cycle On-start  
Note: The right two DIP switch pins are used to select the operating modes.  
114  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Dimensions - 700-HNK Relays  
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.  
47.0  
47.4  
(1.86)  
46.0  
(1.81)  
12.8  
12.8  
(0.50)  
6
(0.23)  
(1.86)  
(0.50)  
46.0  
(1.81)  
6.0  
(0.23)  
28.8  
(1.30)  
31.2  
(1.22)  
28.8  
(1.13)  
31.2  
(1.22)  
700-HNK41 SPDT Contact  
700-HNK42 DPST-NO Contact  
7.11  
(9/32)  
2.03  
(5/64)  
2.03  
(5/64)  
7.11  
21  
6
11  
3
(9/32)  
Five M3.5  
x 0.315 Screws  
11  
4
22  
Eight  
4.06  
(5/32)  
7
M3.5 x 0.315  
Screws  
14  
3
12  
2
24  
5
4.06  
(5/32)  
12  
(1)  
2
3.0 Ø  
(1/8)  
Use M3 Screws  
39.5  
(1-17/32)  
35.5  
(1-13/32)  
14  
84.1  
(3-5/16)  
39.5  
(1-17/32)  
4
84.1  
(3-5/16)  
(1)  
3.0 Ø  
(1/8)  
35.5  
(1-13/32)  
5 (+)  
(A1)  
Use M3 Screws  
8 (+)  
(A1)  
1 (-)  
(A2)  
4.06  
(5/32)  
4.06  
(5/32)  
1 (-)  
(A2)  
29.9  
(1-3/16)  
15.6  
(5/8)  
29.9  
(1-3/16)  
15.6  
(5/8)  
54.1  
(2-1/8)  
54.1  
(2-1/8)  
Cat No. 700-HN121  
Cat No. 700-HN122  
2
2
Wire Size: 2 x 2.5 mm  
Wire Size: 2 x 2.5 mm  
Single Wire – Up to #12 AWG  
Single Wire – Up to #12 AWG  
2
2
Double Wire – 2 x 2.5 mm (#2–14 AWG… #2–20 AWG)  
(Either Solid or Stranded)  
Double Wire – 2 x 2.5 mm (#2–14 AWG… #2–20 AWG)  
(Either Solid or Stranded)  
Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)  
Total height: 700-HN121 + 700-HNK41 is 78.0 mm.  
Strip Length: 9 mm (3/8 in.) – Torque: 0.8 N•m (7 lb•in)  
Total height: 700-HN122 + 700-HNK42 is 78.0 mm.  
(1) Holes required for mounting [3 mm (1/8 in.) diameter].  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
115  
Relay and Timer Specifications  
700-HR Dial Timing Relays  
Socket- or panel-mounted  
5 A contact ratings or transistor outputs  
Single- or Multi-Function  
Timing range from 0.05 s…300 hr  
Multi-voltage inputs  
Multi-Function Timing Relays with Trigger and Reset Switch Options  
Socket or Panel Mounted  
Timing Range From 0.05 s…300 hr  
11-pin base for socket cat. nos. 700-HN101, -HN126, -HN129  
Trigger: Power on or optional trigger signal  
Reset: Power off or optional reset signal  
Timing Mode  
Supply Voltage  
Trigger Options  
Reset Options  
Outputs  
Cat. No.  
1. Power On  
DPDT  
700-HR52TU24  
1. Power Off  
2. Start Signal  
2. Reset Signal  
- contact closure (zero volts)  
- NPN transistor  
3. Gate Signal (pause)  
- contact closure (zero volts)  
- NPN transistor  
Transistor  
DPDT  
700-HRT6TTU24  
(1)  
24…48V AC  
12…48V DC  
On-Delay (A)  
1. Power On  
2. Start Signal  
- contact closure (voltage)  
- NPN transistor  
- PNP transistor  
OFF-Delay (D)  
One Shot (E)  
Power Off  
700-HRV52TU24  
Repeat cycle OFF-Start (B)  
Repeat Cycle ON-Start (B2)  
Signal ON/OFF-delay (C)  
Delayed One Shot (J)  
Signal ON/OFF - Delay (G)  
1. Power On  
1. Power Off  
2. Start Signal  
2. Reset Signal  
DPDT  
DPDT  
700-HR52TA17  
- contact closure (zero volts)  
3. Gate Signal (pause)  
- contact closure (zero volts)  
100…240V AC  
100…125V DC  
1. Power On  
(1)  
2. Start Signal  
Power Off  
700-HRV52TA17  
- contact closure (voltage)  
(1) Voltage input connection to high signal instead of OV signal.  
Multi-Function Timing Relays with Power On Trigger  
Socket or Panel Mounted  
Timing Range From 0.05 s…300 hr  
8-pin base for socket cat. nos. 700-HN100, -HN125, -HN108  
Tri g g e r : Powe r o n  
Reset: Power off  
Timing Mode  
Supply Voltage  
Trigger Options  
Reset Options Outputs  
Cat. No.  
DPDT  
700-HRS42TU24  
24…48V AC  
12…48V DC  
Power On  
Power Off  
Power Off  
Power Off  
ON-Delay (A)  
One Shot (E)  
Repeat Cycle OFF-Start (B)  
Repeat Cycle ON-Start (B2)  
Delayed One Shot (J)  
Transistor  
700-HRT4TTU24  
700-HRP42TU24  
(1)  
24…48V AC/DC  
Power On  
Power On  
SPDT Timed + Instantaneous Contact  
SPDT Timed + Instantaneous Contact  
DPDT  
700-HRP42TA17  
700-HRS42TA17  
100…240V AC  
100…125V DC  
(1) Voltage input connection to high signal instead of OV signal.  
116  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
ON-Delay Timing Relays  
Socket or Panel Mounted  
Timing Range From 0.05 s…300 h  
8-pin base for socket cat. nos. 700-HN100, -HN125, -HN108  
Tri g g e r : Powe r o n  
Reset: Power off  
Timing Mode Supply Voltage  
Trigger Options Reset Options Outputs  
Cat. No.  
24…48V AC/DC  
SPDT Timed + Instantaneous Contact  
700-HRC12TU24  
700-HRM12TU24  
700-HRM12TA17  
700-HRC12TA17  
Power On  
Power Off  
24…48V AC, 12…48V DC  
DPDT  
ON-Delay (A)  
DPDT  
100…240V AC  
Power On  
Power Off  
SPDT Timed + Instantaneous Contact  
Timing Mode Description  
700-HRF Repeat Cycle Timing Relays  
Socket or Panel Mounted  
Independently adjustable on- and off-time  
8-Pin base for socket cat. nos. 700-HN100, -HN125, and -HN108  
DPDT contact outputs  
Tri g g e r : Powe r o n  
Reset: Power off  
Hazardous location version available  
700  
HRF  
7
2
D
U26  
a
b
c
d
e
f
Catalog Number Explanation  
a
d
b
c
e
f
-
Bulletin  
Type of Relay  
Function  
Timing Range  
Supply Voltage  
Contact Output  
Number  
7–Repeat cycle with OFF start  
8–Repeat cycle with ON start  
U26 - 12…48V DC, 24…48V AC  
U27 - 100…125V DC, 100…240V AC  
HRF–Repeat cycle with  
adjustable ON/OFF times  
700  
2- DPDT  
D–0.05 s…300 hr  
700-HRY Star-Delta Timing Relays  
8-Pin base for socket cat. nos. 700-HN100, -HN125, and -HN108  
SPDT timed + instantaneous contact outputs  
Tri g g e r : Powe r o n  
Reset: Power off  
700  
HRYY  
6
F
A12  
a
b
c
d
e
Catalog Number Explanation  
a
b
c
d
e
-
Bulletin  
Type of Relay  
Function  
Timing Range  
Supply Voltage  
Number  
F–Star: 0.5…120 s  
Delta: 0.05, 0.1, 1.25, 0.5, 0.75, 1.0 s  
A12–100…120V AC, 50/60 Hz  
A22–200…240V AC, 50/60 Hz  
700  
HRYY–YStar-Delta timer  
6–SPDT timed + SPDT instant  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
117  
Relay and Timer Specifications  
700-HRQ True Off-Delay Timing Relays  
11-Pin base for use with reset option — socket cat. nos. 700-HN101, -HN126, and -HN129  
8-Pin base for use without reset option — socket cat. nos. 700-HN100, -HN125, and -HN108  
DPDT contact outputs  
Trigger: Power off  
Reset: optional reset signal  
700  
HRQ  
N
2
G
A12  
a
b
c
d
e
f
Catalog Number Explanation  
a
b
d
c
e
f
-
Bulletin  
Type of Relay  
Contact  
Function  
Timing Range  
Supply Voltage  
Number  
Output  
A12–100…120V AC, 50/60 Hz  
A22–200…240V AC, 50/60 Hz  
U25–24V AC, 50/60 Hz; 24V DC  
Z48–48V DC  
N–No reset option, 8-pin terminals  
R–Reset option, 11-pin terminals  
G–0.05…12 s  
H–0.05…12 min  
HRQ–True Off-  
Delay Timer  
700  
2–DPDT  
Z11–100…125V DC  
Accessories - 700-HR Relays  
Photo  
Description  
Pkg. Qty. Cat. No.  
Screw Terminal Tube Base Socket — Panel or DIN Rail Mounting; Guarded Terminal  
Construction. 8-Pin for use with 700-HR and -HX timing relays.  
10  
700-HN100  
Screw Terminal Tube Base Socket — Panel or DIN Rail Mounting; Open Style  
10  
10  
700-HN125  
700-HN101  
Construction. 8-Pin for use with 700-HR and -HX timing relays. No retainer clip required.  
Screw Terminal Tube Base Sockets — Panel or DIN Rail Mounting; Guarded Terminal  
Construction. 11-pin for use with 3PDT 700-HA relays.  
Screw Terminal Tube Base Sockets — Panel or DIN Rail Mounting; Open Style  
10  
10  
700-HN126  
199-DR1  
Terminal Construction. 11-pin for use with 3PDT 700-HA relays. No retainer clip required.  
DIN (#3) symmetrical hat rail  
35 x 7.5 x 1 m  
118  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Photo  
Description  
Pkg. Qty. Cat. No.  
Specialty Socket  
8-pin backwired socket with solder terminals for use with 700-HR timing relays. Order 10 or  
multiples of 10.  
10  
10  
700-HN108  
700-HN129  
Specialty Socket  
11-pin back-wired socket with solder terminals for use with 700-HR timing relays.  
Frame Adapter  
For flush or door mounting of all 700-HR and -HX timers.  
1
700-HN130  
Retainer Clip for Cat. Nos. 700-HN100 and -HN101 Sockets with all 700-HR Timing  
Relays  
Secures timer in socket.  
10  
1
700-HN131  
700-HN132  
Note: Not required for installation  
Protective Cover  
Helps prevent tampering of timing and mode settings. Provides a degree of protection against  
water and dirt from entering the front of the relay. For use with all 700-HRs and -HX timing  
relays.  
Pre-Printed Identification Tags — contains 10 sheets of pre-printed and blank tags. Each  
sheet contains 13 sets of the markings CR…9CR, TR…9TR, M…9M, F, R, 1S, and 117 blank  
tags. Tags are peel-off with sticky backing for easy placement on relays.  
10  
10  
700-N40  
700-N41  
Blank Identification Tags — contains 10 sheets of blank identification tags for customer  
specialized printing. Each sheet contains 546 blank tags. Tags are peel-off with sticky backing  
for easy placement on relays.  
Timer Type  
Socket Cat. No.  
700-HN101  
Retainer Clip Cat. No.  
700-HN131  
(1)  
700-HR52, -HRT6, -HRV, -HRQR  
700-HN126  
700-HN129  
700-HN100  
700-HN108  
700-HN125  
Not Required (3)  
Not Applicable  
700-HN131(See note above)  
Not Applicable  
Not Required(3)  
(2)  
700-HRS, -HRT4, -HRP, -HRC, -HRM, -HRF, -HRY, -HRQN  
(1) 11 pins.  
(2) 8 + pins.  
(3) Design of these sockets holds the timing relays securely and does not require retainer clips.  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
119  
Relay and Timer Specifications  
Specifications - 700-HR Relays  
700-HR,  
700-HRS,  
700-HRV  
700-HRP  
700-HRC  
700-HRM  
700-HRF  
700-HRY  
700-HRQ  
700-HRT  
(Transistor  
Outputs)  
Electrical Ratings  
Pilot Duty Rating  
NEMA B300  
5 A  
100 mA @ 30V  
DC max.  
Thermal Current (I  
)
th  
120V AC  
240V AC  
120V AC  
240V AC  
30 A  
15 A  
3 A  
Make  
Break  
1.5 A  
1/6 Hp (0.12  
kW)  
1/4 Hp (0.18 1/6 Hp (0.12  
kW) kW)  
Hp at 120V  
1/4 Hp (0.18 kW)  
1/6 Hp (0.12 kW)  
1/3 Hp (0.25 kW)  
5 A at 250V AC/30V DC  
AC-15 @ 250V AC, 3 A/DC-13 @ 30V DC, 0.5 A  
0.2% FS max. ( 0.2% 10 ms max. in a range of 1.2 s)  
Hp at 240V  
Resistive Load  
Inductive Load  
Accuracy of Operating Time  
Setting Error  
5 % FS 50 ms (The value is 5% FS +100 ms to -0 ms max. when the C or D mode signal of the 700-HRVs are OFF.)  
0.2% FS max. ( 0.2% 10 ms max. in a range of 1.2 s)  
Influence of Voltage  
Influence of Temperature  
Permissible Leakage Current  
Power Consumption  
240V AC, Output ON  
240V AC, Output OFF  
24V DC, Output ON  
1% FS max. ( 1% 10 ms max. in a range of 1.2 s)  
-HR52,-HRS  
2.1 VA  
-HRV  
2.5 VA  
1.8 VA  
0.9 W  
0.3 W  
-HRP,-HRC  
2.0 VA  
2.0 VA  
0.9 W  
-HRM  
2.1 VA  
1.3 VA  
0.8 W  
0.2 W  
-HRF  
10 VA  
10 VA  
1.0 W  
1.0 W  
-HRY  
12 VA  
12 VA  
-HRQ  
0.4 VA  
0.4 VA  
0.2 W  
0.2 W  
-HRT  
1.3 VA  
0.8 W  
0.3 W  
0.2 W  
24V DC, Output OFF  
Design Specifications  
0.2 W  
0.9 W  
2000V AC (1000V AC for 700-HRT), 50/60 Hz for 1 min (contact to frame)  
2000V AC (1000V AC for 700-HRT), 50/60 Hz for 1 min (between control output terminals and operating circuit)  
2000V AC, 50/60 Hz for 1 min (pole-to-pole)  
Dielectric Strength  
1000V AC, 50/60 Hz for 1 min (between contacts not located next to each other)  
2000V AC, 50/60 Hz for 1 min (contact to coil)  
Mechanical  
Vibration Resistance  
Malfunction: 10…55 Hz with 0.5 mm double amplitude each in three directions for ten minutes each  
2
2
98 m/s (10 294 m/s (10  
2
2
2
Shock Resistance  
Environmental  
Noise Immunity  
Static Immunity  
Ambient Temperature  
Malfunction: 100 m/s (10 G)  
98 m/s (10 G) 100 m/s (10 G)  
G)  
G)  
1kV for 48V  
DC  
1.5 kV for  
600V DC  
1.5 kV for 600V DC  
400V for 12V DC  
Malfunction: 8 kV  
Operating: -10…+55 °C ( 14…131 °F) with no icing  
Storage: -25…+65 °C ( 13…149 °F) with no icing  
Ambient Humidity  
Operating: 35…85 %  
Construction  
7
Life Rxpectancy (Min.  
Operations)  
Mechanical:20 000 000. (under no load at 1800 operations/h)  
Electrical: 100 000 (5 A at 250V AC, resistive load at 1800 operations/h)  
Mech: 10  
4
Electrical: 10  
120  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
700-HR,  
700-HRS,  
700-HRV  
700-HRP  
700-HRC  
700-HRM  
700-HRF  
700-HRY  
700-HRQ  
700-HRT  
(Transistor  
Outputs)  
(EMI) EN50081-2  
Emission Enclosure: EN55011 Group 1 class A  
Emission AC Mains: EN55011 Group 1 class A  
(EMS) EN50082-2  
Immunity ESD:EN61000-4-2: 4 kV contact discharge (level 2); 8 kV air discharge (level 3)  
Immunity RF-interference from AM Radio Waves: ENV50140:10 V/m (80 MHz…1 GHz) (level 3)  
Immunity RF-interference from Pulse-modulated Radio Waves: ENV50204:10 V/m (900 5 MHz) (level 3)  
Immunity Conducted Disturbance: ENV50141: 10V (0.15…80 MHz) (level 3)  
Immunity Burst: EN61000-4-4:2 kV power-line (level 3)  
EMC  
Immunity Surge: EN61000-4-52 kV I/O signal-line (level 4)  
1 kV line to line; 2 kV line to ground (level 3)  
Degree of Protection  
Weight  
IP40 (panel surface)  
Approx. 90 g  
Certifications  
Standards  
CSA Certified (File No. 70751), UL Recognized (File No. E14843 Guide No. NRNT2), CE Marked, C-Tick Marked  
UL 508, CSA C22.2 No. 14, EN 61812-1, EN 61000-6-2, -6-4  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
121  
Relay and Timer Specifications  
Timer Functions - 700-HR Relays  
700-HR Multifunction Timer  
Power indicator (green) (Flashes when Timer operates;  
lit when Timer stops operating)  
Operating mode display window  
Operating mode selector  
Select a mode from:  
A, B, B2, C, D, E, J, and G (700-HR52, -HRV, and HRT 6)  
A, E, B2, J, and B (800-HRS, -HRP, and -HRT4)  
Output indicator (orange)  
(Lit when energized)  
Scale range display windows  
Time unit display window  
Time Range selector (select  
one from 1.2, 3, 12, and 30 at  
full scale.)  
Time unit selector (select one from sec, 10 s, min, 10 m, hrs, and 10 h)  
Time setting  
knob (set time)  
700-HRC -HRM On-Delay Timer  
Power indicator (green) (Flashes when Timer operates;  
lit when Timer stops operating)  
Output indicator (orange)  
(Lit when energized)  
Scale range display windows  
Time unit display window  
Time Range selector (select  
one from 1.2, 3, 12, and 30 at  
full scale.)  
Time unit selector (select one from sec, 10 s, min, 10 m, hrs, and 10 h)  
Time setting  
knob (set time)  
700-HRF Twin Timer  
OFF indicator (green)  
Lit when the output is OFF.  
OFF-time unit display  
ON indicator (orange)  
Lit when the output is ON.  
OFF-time unit selector (select  
one from sec, 10 s, min., 10 m, hrs, and 10 h)  
Scale range display windows  
ON-time setting knob (with orange pointer)  
For ON-time setting  
OFF-time setting knob (with green pointer)  
For OFF-time setting  
Time range selector (select  
one from 1.2, 3, 12, and  
30 at full scale.)  
ON-time unit display  
ON-time unit selector (select  
one from sec, 10 s, min., 10 m, hrs, and 10 h)  
700-HRY Star-Delta Timer  
Star operation indicator  
(green)  
Delta operation indicator  
(orange)  
Time unit display  
(sec. is fixed)  
Scale range display windows  
Time setting knob (for setting  
star operation time)  
Star-delta transfer time selector (select  
one from 0.05 s, 0.1 s, 0.25 s, 0.5 s, 0.75 s and 1.0 s)  
Star operation time range selector  
(select one from 6, 12, 60 and  
120 at full scale.)  
Star-delta transfer time unit display  
700-HRQ True Off-Delay Timer  
Scale range display windows  
Output indicator (red)  
Time setting knob (for setting OFF-delay time)  
Time range selector (select one from 0.6, 1.2, 6, and 12  
at full scale.)  
True OFF-Delay time unit display  
122  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Specifications for Start, Gate, Reset Signal (Cat. Nos. 700-HR52, -HRT6, -HRV, -HRQR)  
Start, Reset, and Gate signals are typically contact closures or signals from a solid-state sensor.  
t <T  
1
(R) Reset Signal  
T
t
1
The reset signal is not required for normal operation. Reset can be accomplished by  
Power toTiming Relay  
removing power from the timing relay. To reset the timer without removing power,  
a signal must be applied which resets the timing cycle and returns the output  
contacts to their shelf state. The reset signal will override both the start signal and  
gate signal. The reset signal can be either momentary or maintained.  
Reset Signal  
Timing Cycle  
Timing Relay Output  
(G) Gate Signal  
t +t =T  
2
1
t
t
The gate signal is not required for normal operation. The gate signal provides a  
pause or retentive timing function. When the gate signal is applied the timing  
cycle is momentarily interrupted. When the signal is removed, the timing cycle  
resumes timing at the point the cycle was interrupted and will continue timing  
until the time delay is completed or the gate signal is  
2
1
Power toTiming Relay  
Gate (pause)  
Timing Cycle  
Timing Relay Output  
re-applied.  
Contact Signal — Cat. Nos. 700-HR52, -HRT6, -HRQR  
Contact closure provides signal to timer. A low energy signal is generated by the  
700-HR timing relay. For optimum reliability, use contacts designed for low energy  
switching (5V, 1 mA)  
(Bul. 800F-X V, 800T-X V). No external voltage should be connected to the  
contact signal.  
R
S
G
5v, 1mA  
Contact Signal — Cat. No. 700-HRV  
For use in applications where it is not possible to use contacts designed for low  
energy switching. Contact closure provides signal to timer. A signal is generated by  
the 700-HR timing relay, and is the same potential as the supply voltage of the  
timing relay. No external voltage should be connected to contact signal. 700-  
HRV52TU24 supply voltage: 24...48V AC, 12...48V DC /  
S
U
700-HRV52TA17 supply voltage: 100...240V AC, 100...125V DC.  
U
+
(
)
(
)
+ 12...24V DC  
COM  
Solid-State Signal — Cat. Nos. 700-HR52, -HRT6  
R
0.1mA  
S
Timing relay is suitable for use with a 3-wire NPN 12...24V DC sensor. Supply  
voltage potential of sensor must be the same as the supply voltage potential of the  
timing relay. Permissible off-state leakage current from sensor: 0.01 mA max.  
G
(
)
(+) 12...24V DC  
COM  
+ 12...24 V DC  
COM  
+ 12...24V DC  
COM  
Solid-State Signal — Cat. No. 700-HRV  
S
S
Timing relay is suitable for use with a 3-wire NPN or PNP 12...24V DC sensor.  
Supply voltage potential of sensor must be the same as the supply voltage  
potential of the timing relay. Permissible off-state leakage current from sensor:  
0.01 mA max.  
(
)
COM  
(
)
(+) 12...24V DC  
COM  
NPN Wiring Diagram  
PNP Wiring Diagram  
(+) 12...24V DC  
Signal Specifications  
Circuit impedance can be used to calculate the maximum wiring distance from the signal switch to the timing relay, for example.  
Permissiblesignal-ONimpedance:1 k max.  
Permissible signal-OFF impedance: 100 k min.  
Circuit Impedance  
Ω
Ω
Power-OFF Reset  
Signal Duration  
Min. power-off time: 0.1 s, Reset Voltage: 10% max. of rated voltage  
Min. pulse width: 0.05 s  
700-HR52  
700-HRT6  
700-HRV5  
700-HRQR  
Start  
Reset  
Gate  
X
X
X
X
X
X
X
NA  
X
Signal Options  
NA  
NA  
NA  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
123  
Relay and Timer Specifications  
Timing Charts - 700-HR Relays  
Mode A — ON-Delay  
a. Needs continuous input power applied.  
b. Timing is initiated by the leading edge of the start signal.  
c. Contacts change state after timing is complete.  
d. Additional start signals during timing don't reset timing or contacts.  
e. When the input power is removed contacts return to shelf state.  
Basic Operation  
T
T
Power  
Power  
Start  
Start  
Output (N.C.)  
Output (N.O.)  
Output  
Power LED  
Mode B — Repeat Cycle, Off Start  
a. Need continuous input power applied.  
b. Timing is initiated by the leading edge of the start signal. Additional start signals during timing do not reset timing or contacts.  
c. For the first time period the contacts remain in their shelf state. When that time period is complete contacts change state for the same time period (time on = time off).  
d. This cycle repeats itself until input power is removed or reset signal is applied. When the input power is removed or reset signal is applied contacts return to the shelf state.  
Basic Operation  
T
T
T
T
T
T
Power  
Start  
Power  
Start  
Output (N.C.)  
Output (N.O.)  
Power LED  
Output  
Mode B2 —Repeat Cycle On start  
a. Need continuous input power applied.  
b. Timing is initiated by the leading edge of the start signal. Additional start signals during timing do not reset timing or contacts.  
c. For the first time period the contacts change state. When that time period is complete contacts return to the shelf state for the same time period (time on = time off).  
d. This cycle repeats itself until input power is removed or reset signal is applied. When the input power is removed or reset signal is applied contacts return to the shelf state.  
Basic Operation  
T
T
T
T
T
T
Power  
Start  
Power  
Start  
Output (N.C.)  
Output  
Output (N.O.)  
Power LED  
Mode C — Watchdog monitor (Trigger = Signal On/Off)  
a. Need continuous input power applied.  
b. Contacts change state immediately when start signal is applied or when start signal is removed (only if timing cycle was complete).  
c. Timing is initiated at the leading edge of the start signal. After the first timing cycle is complete, timing is initiated by the trailing edge of the start signal.  
d. At the end of the time period contacts return to the shelf state.  
e. Relay timing is reset when additional start signals are applied while the relay is timing. Contacts remain in energized state.  
f. When the input power is removed contacts return to the shelf state.  
t<T  
T
t
T
T
Basic Operation  
T
Power  
Start  
T
Power  
Start  
Output (N.C.)  
Output (N.O.)  
Power LED  
Output  
124  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Mode D — Off-Delay (Trigger = Signal Off)  
a. Need continuous input power applied.  
b. Contacts change state immediately when start signal is applied.  
c. Timing is initiated by the trailing edge of the start signal.  
d. At the end of the time period contacts return to the shelf state.  
e. Relay timing is reset when additional start signals are applied while the relay is timing. Contacts remain in energized state.  
f. When the input power is removed contacts return to the shelf state.  
Basic Operation  
t
T
T
t<T  
Power  
Start  
Power  
Start  
Output  
Output (N.C.)  
Output (N.O.)  
Power LED  
Mode E — One-Shot (Trigger = Signal On) 700-HR52, -HRV, and -HRT6  
a. Need continuous input power applied.  
b. Timing is initiated by the leading edge of the start signal.  
c. Contacts change state immediately when start signal is applied.  
d. At the end of the time period contacts return to the shelf state.  
e. Relay timing is reset when additional start signals are applied while the relay is timing. Contacts remain in energized state.  
f. When the input power is removed contacts return to shelf state.  
Basic Operation  
t<T  
t
T
T
T
Power  
Power  
Start  
Output (N.C.)  
Output (N.O.)  
Power LED  
Start  
Output  
Mode E — One-Shot (Trigger = Power On) 700-HRS, -HRP, and -HRT4  
a. Need continuous input power applied.  
b. iming is initiated when the input power is applied.  
c. At the end of the time period contacts return to the shelf state.  
d. Relay timing is reset when input power is removed.  
Basic Operation  
t<T  
T
T
Power  
Power  
Timed Output (N.C.)  
Output  
Timed Output (N.O.)  
Power LED  
Mode G — Watchdog Monitor (Trigger=Signal ON/OFF)  
a. Need continuous input power applied.  
b. Timing is initiated by the landing edge of the start signal.  
c. After the first timing cycle is complete the contacts change state and timing is initiated by the trailing edge of the start signal.  
d. At the end of the time period the contacts return to the shelf state.  
e. Relay timing is reset when additional start signals are applied while the relay is timing.  
f. When the power is removed contacts return to the shelf state.  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
125  
Relay and Timer Specifications  
Mode J — Delayed One-Shot (Trigger = Power On)  
a. Need continuous input power applied.  
b. No start signal applied.  
c. Timing is initiated when input power is applied.  
d. Contacts change state after the timing for a fixed time of 1s +/-0.5s  
e. At the end of the 1 sec period the contacts return to the shelf state.  
f. When the input power is removed contacts return to the shelf state.  
Basic Operation  
T
Power  
T
1s ±±.5s  
Power  
Output (N.C.)  
1s ±±.5s  
Output (N.O.)  
Power LED  
Output (N.O.)  
Power LED  
Mode Star-Delta  
a. Need continuous input power applied.  
b. No start signal required. Timing is initiated when input power is applied.  
c. Star ouput contact changes state when input power is applied.  
d. After timing is complete star output contact returns to the shelf state then both the star & delta contacts remain in shelf states until transfer time setting is complete.  
e. Delta output contact changes state after transfer time is complete.  
f. Instantaneous contact changes state when input power is applied.  
g. All contacts return to the shelf state when input power is removed.  
Basic Operation  
t
1
t
2
Power  
t
1
t
2
Output (N.C.)  
Power  
Output (N.O.)  
Instantaneous Output  
Output 8-5,  
Output 8-6,  
LED  
LED  
Output 8-5,  
Output 8-6,  
LED  
LED  
Mode True Off-Delay (Trigger = Power Off)  
a. Continuous input power is NOT required.  
b. No start signal applied.  
c. Contacts change state immediately when input power is applied.  
d. Timing starts when input power is removed.  
e. At the end of the time period contacts return to the shelf state.  
f. Relay timing is reset when input power is reapplied while the relay is timing. Contacts remain in energized state.  
t<T  
T
t
T
Basic Operation  
Power  
T
Output (N.C.)  
Power  
Output  
Output (N.O.)  
Relay On LED  
Relay On LED  
126  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Dimensions - 700-HR Relays  
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
127  
Relay and Timer Specifications  
700-HT Plug-in Timing Relay  
Timing Relay (On-Delay or Off-Delay)  
Rugged Pin Style Socket Mounting  
10 A, DPDT Contact Ratings  
0.1 s…30 min Fixed Timing Relay  
0.1 s…3 min Single Adjustable Timing Relay  
Single or Fixed Timing  
Single Range Timing Relay with Pin Style Terminations  
700  
HT  
2
2
A
A2  
a
b
c
d
e
f
Catalog Number Explanation - 700-HT Relays  
b
a
c
d
e
f
-
Type of Relay  
Bulletin  
Operating Mode  
Number of Poles  
Timing Range  
Coil Voltage  
Number  
A– 0.1…10 s  
B– 1.0…100 s  
C– 0.1…10 min  
D– 1.0…100 min  
E – 0.1…10 hr  
U12– 12V DC  
1–On-delay  
2–Off-delay  
U24– 24V AC/DC, 50/60 Hz  
U120– 120V AC/DC, 50/60 Hz  
A2 – 240V AC, 50/60 Hz  
HT -  
700  
2 - 2PDT  
Tube Base Adjustable  
Timing Relay  
Wiring Diagrams  
Operating Mode  
U.S./Canada  
International  
On-Delay  
Socket  
700-HN125 or  
700-HN100  
700-HN100  
Off-Delay  
Socket  
700-HT  
700-HN126 or  
700-HN101  
700-HN101  
DPDT 2-Pole — 2 Form C Contacts  
128  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Fixed Timing Relays  
700-HTF Fixed Timing Relays feature a plug-in tube base. Construction is the same as the 700-HT relay except that  
the adjustment knob has been removed to help prevent unwanted tampering. The timing and output specifications  
are identical to those of the 700-HT relay. Setting time will be 5ꢀ of the time ordered.  
700  
HTF  
2
2
025  
S
A2  
a
b
c
d
e
f
g
Catalog Number Explanation - 700-HTF Relays  
b
a
c
d
e
f
g
-
Type of Relay  
Bulletin  
Operating  
Number of  
Timing Range  
Timing Units  
Coil Voltage  
Number  
Mode  
Poles  
001…999 –  
The three digit code represents a numeric  
value with one decimal place. For  
example: code 001 is 0.1, code 025 is 2.5,  
and code 999 is 99.9  
U12– 12V DC  
S –Seconds  
M –Minutes  
H –Hours  
1–On-delay  
2–Off-delay  
U24– 24V AC/DC, 50/60 Hz  
U120– 120V AC/DC, 50/60 Hz  
A2 – 240V AC, 50/60 Hz  
HTF-  
700  
2 - 2PDT  
Tube Base Fixed Timing  
The acceptable range for each time unit is  
Relay  
listed below:  
Seconds - 001…999  
Minutes - 001…999  
Hours - 001…100  
Socket and Retainer Clip Reference  
Relay Type  
Socket Cat. No.  
700-HN100  
700-HN125  
700-HN101  
700-HN126  
Retainer Clip Cat. No.  
700-HN110  
Not Required(1)  
700-HT12  
700-HT22  
700-HN110  
Not Required(1)  
(1) Design of these sockets holds the relays securely and does not require retainer clips.  
Accessories - 700-HT Relays  
Description  
Pkg. Qty. Cat. No.  
Screw Terminal Tube Base Socket — Panel or DIN Rail Mounting; Guarded Terminal  
Construction. 8-Pin for use with DPDT 700-HA Relays, -HX Digital Timing Relays, -HT (On-Delay) 10  
700-HN100  
700-HN125  
and -HRM, -HRC and -HV (Repeat Cycle) Timing Relays. Order ten or multiples of ten  
Screw Terminal Tube Base Socket — Panel or DIN Rail Mounting; Open Style  
Construction. 8-Pin for use with DPDT 700-HA Relays, -HT (On-Delay) and -HRM, -HRC and -HV  
10  
(Repeat Cycle) Timing Relays. Order must be for 10 sockets or multiples of 10. No retainer clip  
required.  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
129  
Relay and Timer Specifications  
Description  
Pkg. Qty. Cat. No.  
Screw Terminal Tube Base Sockets — Panel or DIN Rail Mounting; Guarded Terminal  
10  
10  
700-HN101  
700-HN126  
Construction. 11-pin for use with 3PDT 700-HA relays.  
Screw Terminal Tube Base Sockets — Panel or DIN Rail Mounting; Open Style  
Terminal Construction. 11-pin for use with 3PDT 700-HA relays. No retainer clip required.  
DIN (#3) symmetrical hat rail  
35 x 7.5 x 1 m  
10  
199-DR1  
Retainer Clip for Cat. Nos. 700-HN100 and -HN101 Sockets with 700-HT Timing  
10  
10  
700-HN110  
700-N40  
Relays(1)Secures relay in socket. Order must be for 10 clips or multiples of 10.  
Pre-Printed Identification Tags — contains 10 sheets of pre-printed and blank tags. Each  
sheet contains 13 sets of the markings CR…9CR, TR…9TR, M…9M, F, R, 1S, and 117 blank  
tags. Tags are peel-off with sticky backing for easy placement on relays.  
Blank Identification Tags — contains 10 sheets of blank identification tags for customer  
specialized printing. Each sheet contains 546 blank tags. Tags are peel-off with sticky backing for 10  
easy placement on relays.  
700-N41  
(1) Refer to 700-HT Timing Relay, Socket, and Retainer Clip Reference Chart.  
130  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Specifications - 700-HT  
Cat. No. 700-HT…  
Electrical Ratings  
Cat. No. 700-HTF…  
Pilot Duty Rating (1)  
NEMA B300  
10 A  
Rated Thermal Current (Ith  
)
250V IEC, 300V UL/CSA  
Rated Insulation Voltage (Ui)  
Make  
Break  
HP  
Make  
Break  
HP  
Inductive  
Contacts  
30 A  
15 A  
10 A  
3 A  
1/2 N.O. 1/3 N.C  
1/2 N.O. 1/3 N.C  
30 A  
15 A  
10 A  
3 A  
1.5 A  
10 A  
1/3  
1/2  
120V AC  
240V AC  
1.5 A  
10 A  
Resistive 28V DC  
85…110% of Nominal Voltage at 50 Hz  
85…110% of Nominal Voltage at 60 Hz  
80…110% of Nominal Voltage at DC  
Permissible Coil Voltage Variation  
24V AC  
2 VA  
4 VA  
AC 120V AC  
Power Consumption  
10%  
4 VA  
240V AC  
DC  
1.3 W  
Design Specification/Test Requirements  
Pole-to-Pole, same  
circuit (VRMS)  
1000V AC  
2000V AC  
Dielectric Withstand Voltage  
Pole-to-Pole, different  
circuits (VRMS)  
Contact-to-Coil (VRMS)  
2000V AC  
100,000 minimum  
1800/hr  
Electrical Life Operations  
Switching Frequency Operations  
Coil Voltages  
See product selection  
Mechanical  
Open Type (Guarded Terminal Sockets)  
Degree of Protection  
Mechanical Life Operations  
Switching Frequency Operations  
Timing  
10 x 106  
18,000/hr  
Continuous  
Duty Cycle  
Repeat Accuracy  
(constant voltage and temperature)  
2% (Time Delay: 0.1…2 s)  
1% (Time Delay: >2 s)  
Repeat Accuracy  
(variable voltage and temperature)  
10%  
5% (Time Delay: 0.1…2 s)  
1% (Time Delay: >2 s)  
Fixed Time Setting Accuracy  
+5%  
-50%  
High End of Range  
Scale Tolerance  
Reset Time  
Low End of Range  
ON Delay  
100 ms  
40 ms  
OFF Delay  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
131  
Relay and Timer Specifications  
Cat. No. 700-HT…  
Cat. No. 700-HTF…  
Environmental  
–28…+65 °C (50 °C max., 240V AC coil)  
Operating  
Storage  
(–18…+149 °F) (122 °F max., 240V AC coil)  
Temperature  
–55…+85 °C  
(–67…+185 °F)  
2000 m (6560 ft)  
Altitude  
Construction  
Molded High Dielectric Material  
Impact Resistant Dust Cover  
Silver Cadmium Oxide  
Insulating Material  
Enclosure  
Contact Material  
Terminal Markings on Socket  
In accordance with EN50 005  
8- or 11-Pin Socket  
(On = 8, Off = 11)  
700-HN100, -HN125  
700-HN101, -HN126  
Sockets  
CSA Certified, File 223833, UL Recognized, File E3125 Guide NLDX 2,UL Listed,whe used with 700-HN100, 700-HN101, 700-HN125,  
and 700-HN126 Sockets, File No. E3125 Guide NLDX, CE Marked  
Certifications  
Standards  
EN 61812-1, CSA 22.2 No. 14, UL 508  
(1) See NEMA Ratings and Test Values on page 5.  
Trigger Signal Cat. Nos. 700-HT  
Contact closure provides signal to timer. A low energy signal is generated by the 700-HT timing relay. For optimum reliability, use  
contacts designed for low energy switching (10V, 1 mA) (Bul. 800F-X__V, 800T-X__V). No external voltage should be connected  
to the contact signal.  
Timing Diagrams - 700-HT Relays  
ON Delay  
OFF Delay  
132  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
700-HV Timing Relay  
Repeat Cycle Timing Relay  
10 A Contact Rating  
DPDT  
Pin Style Terminals  
0.1 s…30 min.  
Repeat Cycle Adjustable Timing  
Two Timing Adjustments T1  
T2  
Repeat Cycle Timing Relays with Pin Style Terminations with 2 Adjustments (T1  
T2)  
Wiring Diagrams  
U.S./Canada  
Operating Mode  
International  
Repeat Cycle  
700-HN125 or  
700-HN100  
700-HV Repeat Cycle Timing Relay DPDT 2-Pole — 2 Form C Contacts  
Socket  
700-HN100  
700  
HV  
3
2
A
A
A2  
a
b
c
d
e
f
g
Catalog Number Explanation - 700-HV Relays  
b
a
c
d
e
f
g
-
Type of Relay  
Bulletin  
Operating  
Number of  
Timing Range  
Timing Range  
Coil Voltage  
Number  
Mode  
Poles  
OFF Time  
ON Time  
Code OFF Time — Type HV  
A – 0.1…10 s  
Code ON Time — Type HV  
A 0.1…10 s  
3 –Power ON  
Repeat Cycle,  
OFF Start  
U12 –12V DC  
B – 1.0…100 s  
B 1.0…100 s  
U24 –24V AC/DC, 50/60 Hz  
U120 – 120V AC/DC, 50/60 Hz  
A2 –240V AC, 50/60 Hz  
HV – Tube Base Repeat  
Cycle Timing Relay  
700  
2 - 2PDT  
C – 0.1…10 min  
D – 1.0…100 min  
E –0.1…10 hr  
C 0.1…10 min  
D 1.0…100 min  
E 0.1…10 hr  
(RepeatCycle,  
OFF/ON  
Delay)  
Socket and Retainer Clip Reference  
Relay Type  
Socket Cat. No.  
700-HN100  
Retainer Clip Cat. No.  
700-HN110  
Not Required(1)  
700-HV  
700-HN125  
(1) Design of these sockets holds the relays securely and does not require retainer clips.  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
133  
Relay and Timer Specifications  
Accessories - 700-HV Relays  
Pkg.  
Qty.  
Photo  
Description  
Cat. No.  
Screw Terminal Tube Base Socket — Panel or DIN Rail Mounting; Guarded Terminal  
Construction. 8-Pin for use with DPDT 700-HA Relays, -HX Digital Timing Relays, -HT (On-Delay) and - 10  
700-HN100  
HRM, -NRC and -HV (Repeat Cycle) Timing Relays. Order ten or multiples of ten  
DIN (#3) symmetrical hat rail  
35 x 7.5 x 1 m  
10  
199-DR1  
Screw Terminal Tube Base Socket — Panel or DIN Rail Mounting; Open Style Construction. 8-  
Pin for use with DPDT 700-HA Relays, -HT (On-Delay) and -HRM, -HRC and -HV (Repeat Cycle) Timing  
Relays. Order must be for 10 sockets or multiples of 10. No retainer clip required.  
10  
10  
700-HN125  
Pre-Printed Identification Tags — contains 10 sheets of pre-printed and blank tags. Each sheet  
contains 13 sets of the markings CR…9CR, TR…9TR, M…9M, F, R, 1S, and 117 blank tags. Tags are  
peel-off with sticky backing for easy placement on relays.  
700-N40  
700-N41  
Blank Identification Tags — contains 10 sheets of blank identification tags for customer specialized  
printing. Each sheet contains 546 blank tags. Tags are peel-off with sticky backing for easy placement on 10  
relays.  
134  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Specifications - 700-HV Relays  
Cat. No. 700-HV…  
Electrical Ratings  
Pilot Duty Rating‡  
NEMA B300  
10 A  
Rated Thermal Current (Ith  
)
Rated Insulation Voltage (Ui)  
250V IEC, 300V UL/CSA  
Make  
Break  
Inductive  
Hp  
Contacts  
120V AC  
30 A  
15 A  
10 A  
3 A  
1/2 N.O. 1/3 N.C.  
240V AC  
1.5 A  
10 A  
1/2 N.O. 1/3 N.C.  
Resistive 28V DC  
85…110 of Nominal Voltage at 50 Hz  
85…110 of Nominal Voltage at 60 Hz  
80…110 of Nominal Voltage at DC  
Permissible Coil Voltage Variation  
24V AC  
2 VA  
4 VA  
AC  
120V AC  
240V AC  
Power Consumption  
10%  
4 VA  
DC  
1.3 W  
Design Specification/Test Requirements  
Pole-to-Pole, same circuit (VRMS)  
1000V AC  
2000V AC  
Pole-to-Pole, different circuits  
(VRMS)  
Dielectric Withstand Voltage  
Electrical Life Operations  
Contact-to-Coil (VRMS)  
2000V AC  
100,000 minimum  
1800/hr  
Switching Frequency Operations  
Coil Voltages  
See product selection  
Mechanical  
Degree of Protection  
Mechanical Life Operations  
Switching Frequency Operations  
Timing  
Open Type (Guarded Terminal Sockets)  
10 x 106  
18,000/hr  
Continuous  
Duty Cycle  
Repeat Accuracy  
(constant voltage and temperature)  
2% (Time Delay: 0.1…2 s)  
1% (Time Delay: >2 s)  
Repeat Accuracy  
(variable voltage and temperature)  
10%  
High End of Range  
Low End of Range  
+5%  
-50%  
Scale Tolerance  
Reset Time  
100 ms  
Environmental  
–28…+65 °C (50 °C max., 240V AC coil)  
(–18…+149 °F) (122 °F max., 240V AC coil)  
Operating  
Storage  
Temperature  
–55…+85 °C  
(–67…+185 °F)  
Altitude  
2000 m (6560 ft.)  
Construction  
Insulating Material  
Enclosure  
Molded High Dielectric Material  
Impact Resistant Dust Cover  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
135  
Relay and Timer Specifications  
Contact Material  
Silver Cadmium Oxide  
Terminal Markings on Socket  
In accordance with EN50 005  
8-Pin Socket  
Cat. No. 700-HN100, -HN125  
Sockets  
CSA Certified, File 223833; UL Recognized, File E3125; Guide NLDX 2; cULus Listed when used with 700-HN100 and 700-  
HN125 sockets; CE Marked  
Certifications  
Standards  
EN 61812; CSA 22.2 No. 14; UL 508  
Timing Diagram- 700-HV Relays  
Dimensions - 700-HV Relays  
Approximate Dimensions are shown in millimeters (inches). Approximate Dimensions are not intended to be used for manufacturing purposes.  
700-HV Timing Relay  
Cat. No. 199-DR1 DIN Mounting Rail Series B  
Cat. No. 199-DR4 DIN Mounting Rail Series B Has No Mounting Holes  
Approx.  
Shipping Wt.  
Cat. No.  
199-DR1  
199-DR4  
A
B
C
D
35  
(1-3/8)  
27  
(1-1/16)  
7.5  
(19/64)  
1.02  
(1/64)  
1.85 kg  
(4.07 lbs.) (10/pkg)  
35  
(1-3/8)  
27  
(1-1/16)  
15  
(19/32)  
2.3  
(3/32)  
3.68 kg  
(8 lbs.) (5/pkg)  
136  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Cat. No. 700-HN125  
Wire Size: 2 x 2.5 mm2  
Single Wire—Up to #12 AWG  
Double Wire—2 x 2.5mm2 (#2-14 AWG…#2-20 AWG)  
(Either Solid or Stranded)  
Cat. No. 700-HN100  
Panel Mounting  
Double Wire—2 x 2.5mm2 (#2-14 AWG…#2-20 AWG)  
(Either Solid or Stranded)  
Strip Length: 9 mm (3/8 in) - Torque: 0.8 N•m (7 ib•in)  
Strip Length: 9 mm (3/8 in) - Torque: 0.8 N•m (7 ib•in)  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
137  
Relay and Timer Specifications  
700-HX Multi-Function Digital Timing Relay  
Digital timing relay with LCD display  
Socket- or panel-mounted (NEMA 4X/IP66)  
5A, B300, SPDT contact ratings  
10 Functions or modes  
Environmentally friendly — flash memory, no battery  
No. of  
Pins  
Photo  
Operating Mode  
Timing Range  
Socket Type Contact Output  
Input Voltage Cat. No.  
A mode: Signal ON-Delay 1  
A-1 mode: Signal ON-Delay 2  
A-2 mode: Power ON-Delay 1  
A-3 mode: Power On-Delay 2  
B mode: Repeat Cycle 1  
B-1 mode: Repeat Cycle 2  
D mode: Signal OFF-delay  
E mode: One Shot  
100…240V AC 700-HX86SA17  
0.000…9.999 s  
0.000…99.99 s  
0.000…999.9 s  
0.000…9999 s  
0.000…99 min 59 s  
0.000…999.9 min  
0.000…9999 min  
0.000…99 hr 59  
min  
700-HN100  
SPDT  
8
24V AC  
F mode: Cumulative  
700-HN125  
700-HX86SU24  
12…24V DC  
Z mode: On/Off duty  
adjustable repeat cycle  
S mode:stop watch  
0.000…999.9 hr  
0.000…9999 hr  
toff: Flicker OFF start 1  
ton: Flicker ON start 1  
toff-1: Flicker OFF start 2  
ton-1: Flicker ON start 2  
Socket and Retainer Clip Reference  
Timer Type  
Socket Cat. No.  
700-HN100  
Retainer Clip Cat. No.  
700-HN131  
(1)  
700-HX  
700-HN108  
Not Required  
700-HN125  
Not Required  
(1) Design of socket holds the relay securely and does not require retainer clips.  
Accessories - 700-HX Relays  
Photo  
Description  
Pkg. Quantity  
Cat. No.  
Screw Terminal Tube Base Socket — Panel or DIN Rail Mounting; Guarded Terminal  
Construction. 8-Pin for use with 700-HX Timing Relays. Order ten or multiples of ten  
10  
700-HN100  
Screw Terminal Tube Base Socket — Panel or DIN Rail Mounting; Open Style  
Construction. 8-Pin for use with 700-HX Timing Relays. Order must be for 10 sockets or  
multiples of 10. No retainer clip required.  
10  
10  
700-HN125  
199-DR1  
DIN (#3) symmetrical hat rail  
35 x 7.5 x 1 m  
138  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Photo  
Description  
Pkg. Quantity  
Cat. No.  
Specialty Socket  
10  
10  
700-HN108  
8-pin backwired socket with solder terminals. For use with 700-HX Timing Relays.  
Retainer Clip for Cat. Nos. 700-HN100 Sockets with all 700-HX Timing Relays  
Secures timer in socket.  
700-HN131  
700-HN130  
Note: Not required for installation  
Frame Adapter  
For flush or door mounting of all 700-HR and -HX timers.  
1
1
Protective Cover  
Helps prevent tampering of timing and mode settings. Provides a degree of protection against  
water and dirt from entering the front of the relay. For use with all 700-HR and -HX timing  
relays.  
700-HN132  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
139  
Relay and Timer Specifications  
General Timer Functions- 700-HX Relays  
Display Section  
1. Key Protect Indicator (orange)  
2. Control Output Indicator (orange)  
3. Reset Indicator (orange)  
Operation Key  
4
8. Mode Key  
5
6
(Changes modes and setting items)  
1
2
3
8
9. Reset Key  
7
(Resets present value and output)  
10  
11  
4. Present Value Display (Main display)  
(Character height: 12 mm, red *)  
* Characters on models with screw terminals  
can be switched between red, green, and orange.  
9
10. Up Keys 1 to 4  
Front View  
11. Down Keys 1 to 4  
12  
5. Time Unit Indicators  
Switches  
(Color is same as present value display.)  
(If the time range is 0 min, 0 h, 0.0 h, or 0 h 0 min, these  
indicators flash to indicate timing  
12. Key-protect Switch  
OFF  
ON  
(Enabled)  
(Default setting)  
(Disabled)  
operation.)  
6. Set Value Display (Sub-display)  
(Character height: 6 mm, green)  
7. Set Value 1, 2 Indicator (green)  
Character Size for  
Character Size  
Present Value Display  
for Set Value Display  
12 mm  
6 mm  
140  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Specifications - 700-HX Relays  
Attribute  
700-HX  
Electrical Ratings  
Pilot Duty Rating  
NEMA B300  
Rated supply voltage  
Operating voltage range  
100 to 240V AC, 24V AC/12 to 24V DC (50/60Hz) (permissible ripple: 20%(p-p) max.)  
85…110% of rated supply voltage  
100…240V AC  
24V AC/12…24V DC  
100…240V AC  
24V AC/12…24V DC  
120V AC  
4.3VA  
3.4VA/1.7 W  
3 A  
Power consumption  
Inrush Current  
Make  
5 A  
30 A  
240V AC  
15 A  
120V AC  
3 A  
Break  
240V AC  
1.5 A  
Hp at 120V AC  
Hp at 240V AC  
1/4 Hp  
1/3 Hp  
Mechanical  
Mounting Method  
Display  
Flush mounting, surface mounting, DIN mounting  
Seven-segment, negative transmissive LCD;  
Present value (red, 12 mm high characters);  
Set value (green, 6 mm high characters)  
Digits  
Four digits  
0.000…9.999 s, 0.00…99.99 s, 0.0…999.9 s, 0…9999 s, 0 min 00 s…99 min 59 s,  
0.0…999.9 min, 0 hr 00 min…99 hr 59 min, 0.0 hr…999.9 hr, 0 hr…9999 hr  
Time ranges  
Timer  
Timer modes  
Output modes  
Input signals  
Input method  
Start, reset, gate  
Power reset  
Elapsed time (Up), remaining time (Down), selectable  
A, A-1, A-2, A-3, B, B-1, D, E, F, Z, S, tOFF, tON, tOFF-1, or tON-1  
Start, reset  
No-voltage input via:NPN transistor or switching of contact  
Minimum input signal width: 1 or 20 ms (selectable)  
Minimum power-opening time: 0.5 s (Except for A-3, B-1, and F mode)  
Inputs  
SPDT contact output: 5 A at 250V AC, resistive load (cosine=1)  
Minimum applied load: 10 mA at 5 V DC (failure level: P,reference value)  
Control output  
External Power Supply  
Key Protect  
No  
Yes  
Memory Backup  
EEP-ROM (overwritten 100 000 times min), which can store data for 10 years min.  
Power-ON start: +-0.01% +-50 ms max. (1)to be rated against set value  
(1)  
Signal start: +- 0.005% +-30 ms max. to be rated against set value  
Accuracy of Operating Time and Setting Error (1)  
Signal start at transistor output model: +- 0.005% +-3 ms max. (2)  
If the set value is within the sensor waiting time (250 ms max.)  
(1) The values are based on the set value.  
(2) The value is applied for a minimum pulse width of 1 ms.  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
141  
Relay and Timer Specifications  
Attribute  
700-HX  
Environmental  
Installation environment  
Ambient temperature  
Ambient humidity  
Storage temperature  
Altitude, max  
Setup category II, pollution degree 2 (as per IEC61010-1)  
-10…+55 °C (14…141 °F ), Avoid freezing or condensation  
25…85 %  
-25…+65 °C (-13…149 °F ), Avoid freezing or condensation  
2,000 m  
Characteristics (1)  
Insulation Resistance  
Dielectric Strength  
100 mΩ min.(at500VDC)  
2000V AC, 50/60Hz for 1 min between current-carrying terminals and non-current- carrying  
metal parts (1000V AC for 24V AC/12 to 24V DC type), 1000 VAC, 50/60 Hz for 1 min between non-  
continuous contacts  
1.5 kV (between power terminals) for 100 to 240 VAC, 480V for 24VAC/12 to 24VDC, and  
600V (between input terminals), square-wave noise by noise simulator (pulse width: 100 ns/  
1 μs, 1-ns rise)  
Noise Immunity  
Static Immunity  
8 kV (malfunction), 15 kV (destruction)  
Vibration Resistance  
Shock Resistance  
Malfunction  
10…55 Hz with 0.35 mm single amplitude each in three directions for 10 min  
2
Malfunction  
98 m/s (approx. 10 G) each in three directions  
Mechanical  
10 million operations min. (under no load at 18 000 operation/hr)  
100 000 operations min. (5 A at 250V AC, resistive load at 1800 operation/hr)  
EN61812-1  
Life Expectancy  
Electrical  
(EMI)  
Emission Enclosure:  
Emission AC mains:  
(EMS)  
EN55011 Group1 class A  
EN55011 Group1 class A  
EMC  
EN61812-1  
Immunity ESD:  
Immunity RF-interference:  
EN61000-4-2: 4 kV contact discharge (level2) 8 kV air discharge (level3)  
EN61000-4-3: 10 V/m  
Enclosure Ratings  
Weight  
Panel surface:IP66 and NEMA Type 4 (indoors) (2)  
Approx. 100 g  
Certifications  
Standards  
CE Certified; cURus (File No. E14843, Guide NRNTZ/NRNT8), C-Tick Marked  
EN61010-1, EN 61326, VDE0106/P 100, CSA C22.2 No. 14, UL 508  
(1) More information in the 700-HX User Manual, publication 700-UM002.  
(2) An attached waterproof packing is necessary to ensure IP66 waterproofing between the 700-HX and installation pan.  
142  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Timing Charts- 700-HX Relays  
One-Shot  
One-shot outputs can be set to  
0.1s, 0.5 s, 1 s, 5 s, 10 s, or 20 s.  
Sustained Output  
Output Mode A Mode: Signal ON-Delay (Timer resets when power comes ON.)  
Timing starts when the start signal goes ON.  
Power  
While the start signal is ON, the timer starts when  
power comes ON or when the reset input goes OFF.  
The control output is controlled using a sustained  
or one-shot time period.  
Start signal  
Gate*  
Reset  
Basic Operation  
Power  
**  
t
t
t
Start Signal  
Input  
Control output  
Timing  
Set value  
UP  
0
Output  
Timing  
diagram  
Set value  
*Output is instantaneous when setting is 0.  
** Start signal input is enabled during timing.  
DOWN  
0
Output Mode A-1: Signal ON-Delay 2 (Timer resets when power comes ON.)  
Timing starts when the reset input goes ON and is  
reset when the start signal goes OFF.  
Power  
While the start signal is ON, the timer starts when  
the power comes ON or when the reset input goes OFF.  
The control output is controlled using a sustained  
or one-shot time period.  
Start signal  
Gate*  
Reset  
Basic Operation  
Power  
Control output  
Set value  
Start Signal  
Input  
Timing  
UP  
0
Timing  
diagram  
Output  
Set value  
*Output is instantaneous when setting is 0.  
DOWN  
0
Output Mode A-2: Power ON Delay 1 (Timer resets when power comes ON)  
Power  
Timing starts when the reset input goes OFF.  
The start signal disables the timing function (i.e.,  
same function as the gate input).  
Start signal  
Gate *  
Reset  
The control output is controlled using a sustained  
or one-shot time period.  
Basic Operation  
Power  
Timing  
Control output  
Set value  
Output  
UP  
0
Timing  
diagram  
*Output is instantaneous when setting is 0.  
Set value  
DOWN  
0
Output Mode A-3 Power ON Delay 2 (Timer does not reset when power comes ON)  
Timing starts when the reset input goes OFF.  
Power  
Start signal  
The start signal disables the timing function (i.e.,  
same function as the gate input).  
Gate *  
Reset  
The control output is controlled using a sustained  
or one-shot time period.  
Basic Operation  
Control output  
Set value  
Power  
Timing  
Sustained  
Output  
UP  
0
Timing  
diagram  
*Output is instantaneous when setting is 0.  
Set value  
DOWN  
0
Gate not included on any mode of this relay.  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
143  
Relay and Timer Specifications  
Output Mode B: Repeat Cycle (Timer resets when power comes ON.)  
Timing starts when the start signal goes ON.  
The status of the control output is reversed when time  
is up (OFF at start).  
Sustained Output  
While the start signal is ON, the timer starts when the  
power comes ON or when the reset input goes OFF.  
Power  
Basic Operation  
Start signal  
Power  
Gate*  
Reset  
**  
Start Signal  
Input  
Timing  
Timing  
Timing  
Timing  
Control output  
Set value  
UP  
Output  
0
Timing  
diagram  
Set value  
DOWN  
* Normal output operation will not be possible if the  
set time is too short.  
0
Set the value to at least 100 ms (contact output type).  
** Start signal input is disabled diring timing.  
Timing starts when the start signal goes ON.  
One-Shot Output  
Power  
The control output is turned ON when time is up.  
While the start signal is ON, the timer starts when the  
power cones ON or when the reset input goes OFF.  
Basic Operation  
Start Signal  
Power  
Gate*  
Reset  
**  
Start Signal  
Input  
Timing Timing  
Timing Timing  
Output  
Control Output  
* Normal output operation will not be possible if the  
set time is too short.  
Set the value to at least 100 ms (contact output type).  
** Start signal input is disabled during timing.  
Set Value  
0
Set Value  
UP  
Timing  
Diagram  
0
DOWN  
Output Mode B-1: Repeat Cycle 2 (Timer does not reset when power comes ON)  
Timing starts when the start signal goes ON.  
The status of the control output is reversed when  
time is up (OFF at the start).  
Sustained Output  
While the start signal is ON, the timer starts when the  
power comes ON or when the rest input goes OFF.  
Power  
Basic Operation  
Power  
**  
Start signal  
Start Signal  
Input  
Gate*  
Reset  
Timing  
Timing Sustained  
Control output  
Output  
Set value  
UP  
* Normal output operation will not be possible  
if the set time is too short  
Set the value to at least 100 ms (contact  
output type).  
** Start signal input is disabled during.  
0
Timing  
diagram  
Set value  
DOWN  
0
Timing starts when the start signal goes ON.  
One-Shot Output  
The control output comes ON when time is up.  
While the start signal is ON, the timer starts when  
the power comes ON or when the reset input goes OFF.  
Basic Operation  
Power  
Power  
Start signal  
**  
Start Signal  
Input  
Gate*  
Reset  
Timing  
Timing  
Output  
Sustaining  
Control output  
* Normal outout operation will not be possible if the  
set time is too short.  
Set the value to at least 100 ms (contact output type).  
** Start signal input is disabled during timing.  
Set value  
UP  
0
Timing  
diagram  
Set value  
DOWN  
0
Gate not included on any mode of this relay.  
144  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Output Mode D: Signal OFF-Delay (Timer resets when power comes ON.)  
The control output is ON when the start signal is  
ON (except when the power is OFF or the reset  
is ON).  
The timer is reset when the time is up.  
Power  
Start signal  
Basic Operation  
Gate*  
Reset  
Power  
**  
Start Signal  
Input  
Control output  
Set value  
Timing  
Output  
UP  
0
Timing  
diagram  
Set value  
* Output functions only during start signal input  
when setting is 0.  
** Start signal input is enabled during timing.  
DOWN  
0
Output Mode E: Interval (Timer resets when power comes ON.)  
Timing starts when the start signal comes ON.  
The control output is reset when time is up.  
While the start signal is ON, the timer starts when  
power comes ON or when the reset input goes OFF.  
Power  
Start signal  
Basic Operation  
Gate*  
Reset  
Power  
**  
Start Signal  
Input  
Control output  
Set value  
Timing  
UP  
0
Timing  
diagram  
Output  
Set value  
DOWN  
0
* Output is disabled when the setting is 0.  
** Start signal input is enabled during timing.  
Output Mode F: Cumulative (Timer does not reset when power comes ON)  
Start signal enables timing (timing is stopped when the  
start signal is OFF or when the power is OFF).  
A sustained control output is used.  
Basic Operation  
Power  
Start Signal  
Input  
Timing  
Timing  
Sustained  
Output  
*Output is instantaneous when setting is 0.  
Gate not included on any mode of this relay.  
Z Mode  
Output quantity can be adjusted by changing the cycle time set in the adjustment level to 1 and by changing the ON duty (ꢀ) set value. The set  
value shows the ON duty (ꢀ) and can be set to a value between 0 and 100 (ꢀ). When the cycle time is 0, the output will always be OFF. When the  
cycle time is not 0 and when ON duty has been set to 0 (ꢀ), the output will always be OFF. When ON duty has been set to 100 (ꢀ), the output will  
always be ON.  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
145  
Relay and Timer Specifications  
Z mode: ON/OFF-duty Adjustable Repeat Cycle  
Timing starts when the start signal goes ON.  
The status of the control output is reversed  
when time is up (ON at start).  
While the start signal is ON, the timer starts when  
power comes ON or when the reset input goes OFF.  
Power  
Start signal  
* Gate  
Basic Operation  
Power  
**  
Reset  
Start signal  
input  
Timing  
(cycle time)  
Timing  
(cycle time)  
Control Output  
Cycle time  
Timing  
ON duty (%)  
Timing  
ON duty (%)  
ON duty setting  
(%) ON time  
0
UP  
Output  
Cycle time  
*
Normal output operation will not be possible if the  
set time is too short.  
Timing  
diagram  
ON duty setting  
(%) ON time  
Set the value to at least 100 ms (contact output  
0
DOWN  
type).  
** Start signal input is enabled during timing.  
Output Mode S: Stop Watch (Timer resets when power comes ON)  
The signal starts and stops timing.  
Power  
The display is held and timing is continued if the reset  
or gate input is received during timing operation.  
The timer resets if the reset or gate input is received  
when the timing operation is stopped.  
Start signal  
Basic Operation  
Gate/Reset  
9999  
Power  
Set time  
Start signal  
input  
UP  
Timing  
Gate/Reset  
0
Set time  
DOWN  
0
*
Display  
(for elapsed  
time)  
RST  
*
flashes  
Output  
Note: Output is instantaneous when setting is 0.  
Output Mode T OFF: Twin Timer OFF start  
Timing starts when the start signal goes ON.  
The status of the control output is reversed when time  
is up (OFF at start).  
Sustained Output  
Power  
While the start signal is ON, the timer starts when  
power comes ON or when the reset input goes OFF.  
Start signal  
* Gate  
Basic Operation  
Power  
**  
Reset  
Start Signal  
Input  
Control Output  
OFF Time  
Timing  
OFF  
Timing  
OFF  
Timing  
ON  
Timing  
ON  
UP  
ON Time  
Output  
Timing  
diagram  
0
OFF Time  
* Normal output operation will not be possible if the  
ON/OFF set time is too short. Set the value to at least  
100 ms (contact output type).  
DOWN  
ON Time  
0
** Start signal input is disabled during timing.  
Gate not included on any mode of this Relay.  
146  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Output Mode T ON: Twin Timer ON start  
Sustained Output  
Timing starts when the start signal goes ON.  
The status of the control output is reversed when time  
is up (ON at start).  
Power  
While the start signal is ON, the timer starts when  
power comes ON or when the reset input goes OFF.  
Start signal  
* Gate  
Basic Operation  
Power  
**  
Reset  
Start Signal  
Input  
Control Output  
OFF Time  
Timing  
ON  
Timing  
ON  
Timing  
OFF  
Timing  
OFF  
UP  
ON Time  
Output  
Timing  
diagram  
0
OFF Time  
* Normal output operation will not be possible if the  
ON/OFF set time is too short. Set the value to at least  
100 ms (contact output type).  
DOWN  
ON Time  
0
** Start signal input is disabled during timing.  
Output Mode TOFF-1: Flicker OFF start 2 (Timer does not reset when power comes ON)  
Timing starts when the start signal goes ON.  
The status of the control output is reversed when time is  
up (OFF at start).  
While the start signal is ON, the timer starts when the  
power comes ON or when the reset input goes OFF.  
Power  
Start signal  
Gate  
Basic Operation  
Power  
Reset  
*
Start signal  
input  
Timing  
OFF  
Timing  
ON  
Timing  
OFF  
a
b
Control output  
Output  
OFF time  
UP  
(a + b = ON time)  
* Start signal input is disabled during timing.  
ON time  
Note: Normal output operation will not be possible if  
the set time is too short.  
0
OFF time  
DOWN  
ON time  
Set the value to at least 100 ms (contact output  
type).  
0
Output Mode TON-1: Flicker ON start 2 (Timer does not reset when power comes ON)  
Timing starts when the start signal goes ON.  
The status of the control output is reversed when time is  
up (ON at start).  
While the start signal is ON, the timer starts when the  
power comes ON or when the reset input goes OFF.  
Basic Operation  
Power  
*
input  
Start signal  
Timing  
ON  
Timing  
OFF  
Timing  
ON  
a
b
Output  
(a + b = OFF time)  
* Start signal input is disabled during timing.  
Note: Normal output operation will not be possible if  
the set time is too short.  
Gate not included on any mode of this Relay.  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
147  
Relay and Timer Specifications  
Dimensions- 700-HX Relays  
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.  
14.3  
7.5  
63.7  
48×48  
44.8×44.8  
60 min.  
+0.6  
−0  
45  
+0.6  
−0  
45  
60 min.  
15 min.  
Cat. No. 700-HX…  
Panel Cutout  
12.5  
(1/2)  
1.0  
(0.04)  
6.2  
(15/64)  
50  
(1-63/64)  
5.2  
(13/64)  
35.0  
(1.38)  
27.0  
(1.06)  
7.5  
(0.3)  
1000  
(39-3/8)  
Cat. No. 199-DR1 DIN Mounting Rail Series B  
Cat. No. 199-DR4 DIN Mounting Rail Series B Has No Mounting Holes  
Terminal Arrangement  
Internal circuit  
Signal  
Reset  
4
1
5
8
3
2
6
7
0V  
(–) (+)  
Cat. No. 700-HX…  
148  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
NEMA Industrial Relays  
Product Overview  
Bulletin No.  
Type  
700-P  
700S-P  
700-N  
Heavy-duty control relay  
Heavy-duty control relay  
Industrial Relay  
Contact cartridges convertible from N.O. to  
N.C. and vice versa  
NEMA A300 AC  
Convertible contacts  
Up to 600V AC & DC  
Very long life  
Timer & latch options  
Mechanically linked  
Convertible contacts  
Up to 600V AC & DC  
Very long life  
Timer & latch options  
Mechanically linked  
24…250V AC coils  
Pneumatic timing unit  
Solid-state timing unit  
Overlap contacts  
Features  
Logic reed contacts  
Contact Form  
2…12 poles, double break  
Bifurcated double break  
Bifurcated silver nickel  
2…12 poles, double break  
Bifurcated double break  
Bifurcated silver nickel  
2- or 4-poles  
Contact Type  
Contact Material  
Electrical  
Silver  
Max. Current AC Resistive  
10 A  
10 A  
10 A  
10V, 50 mA  
1 mA, 5V with 700-CPR  
10V, 50 mA  
1 mA, 5V with 700-CPR  
Min. load  
24…600V AC  
6…600V DC  
24…600V AC  
6…600V DC  
Coil Voltage  
85…110% AC coils,  
80…110% DC coils  
85…110% AC coils,  
80…110% DC coils  
Coil Voltage Pickup  
Dielectric Withstand  
Reference  
2640V  
2640V  
Electric Service Life (cycles)  
Certifications  
10 million at 10 A 120V AC  
10 million at 10 A 120V AC  
cULus, CE  
cULus, CE  
UL, CSA, CE  
Sockets  
DIN Rail, relay rail, or panel mount  
151  
DIN Rail, relay rail, or panel mount  
151  
Product Selection  
172  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
149  
Relay and Timer Specifications  
Product Overview  
Bulletin No.  
Type  
700-R  
700-RTC  
Sealed Switch  
Solid-state Timing Relay  
Hazardous location ratings  
Long life in dirty environment  
Timer and latch options  
Timed and instantaneous contacts.  
Sealed contacts for harsh environments and  
hazardous locations.  
Features  
Switch 600V AC, 300V DC  
Contact Form  
Contact Type  
2...8 Poles  
Sealed Switch  
Sealed Switch  
Contact Material  
Electrical  
Max. Current AC Resistive  
Min. load  
5 A  
1 mA, 5V  
24...240V AC  
24...250V DC  
Coil Voltage  
85...110% AC Coils  
80...110% DC Coils  
Coil Voltage Pickup  
Dielectric Withstand  
Reference  
2640V  
Electric Service Life (cycles)  
Certifications  
1.5 million at 5 A 120V AC  
UL, CSA, CE  
Sockets  
Panel or rail mount  
Timing Relay Information  
Control Outputs:  
Time Limit Instantaneous  
Four output contacts  
On-Delay  
Off-Delay  
Timing Operation Modes:  
Time Range  
0.05 s…64 min  
24V AC  
110…120V AC  
220…240V AC  
24V DC  
Supply Voltage  
Product Selection  
120V DC  
240V DC  
176  
181  
150  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
700-P Industrial Relays  
700-P — Direct Drive™ Convertible Contact Cartridge Relays  
NEMA and IEC ratings  
600V maximum AC/DC  
Accessories for field installation: contact cartridges, adder decks, time delay, latching, surge suppressors, mounting strip  
Contact Ratings: (10 A) 700-CP1, (20 A) 700-CPM, (35 A) 700-CPH, (Low Power) 700-CPR  
For machine tool and other heavy-duty applications  
Can accommodate ring tongue terminals  
Integral DIN Rail mount on AC relays  
Finger-safe protection standard  
Factory supplied standard at 120V AC and 24V DC - user configurable for field assembly  
Blank relays are available in all coil voltages for field custom configuration  
Contact cartridge is convertible from N.O. to N.C. by simply turning cartridge over.  
The 700/700DC-P family of Direct Drive Industrial Relays offers switching solutions ranging from 200 mA in Low Energy Circuits to 35 A in  
Heavy Duty Circuits. All of the contacts can easily be changed from the standard N.O. to N.C. configuration. The relays can be accessorized to  
meet the application needs with the use of time delayed contacts, mechanical latches and NEMA enclosures. All devices are available in the most  
popular AC and DC control voltages. Combining different cartridges into one relay can yield a custom-tailored application solution. Relays are  
available without contact cartridges in all of the available AC and DC coil voltages for maximum flexibility.  
700/700DC-P relays use standard (10 A) contact cartridges with a double-break and bifurcated design. Bifurcation provides excellent contact  
reliability and low-contact bounce, while the double-break contact design reduces the possibility of contacts welding and enhances the relay’s ability  
to break DC circuits. These relays can be configured with a maximum of 12 contacts (only 8 may be N.C.).  
A Modular Approach to Control Circuit Solutions  
The 700-P AC control relay is factory assembled with a standard 10 A contact cartridges with all contacts as N.O.in either 2, 4, 8, or 12 pole  
configurations with a 120 volt operating coil. Four pole relays are also available at 240 and 480 VAC and can have up to eight contacts added by  
using adder decks. The 700DC-P control relay is factory assembled with a standard 10 A contact cartridges with all contacts as N.O. in either 4 or 8  
poles with a 24 volt operating coil. The 4 pole is also available with a 120 VDC operating coil.  
For control relays that require different contact ratings or control voltages we offer a modular design that are easily field configurable. A base blank  
relay (either AC or DC control), a variety of contact kits, adder decks, and operating coils can be used to make an infinite number of custom control  
relay solutions.  
Master Control 700-PMCKIT master control cartridges provide (20 A) switching capability with large single-contact pads on each side of  
the spanner for twice the current rating to control heavy loads and provide for master control of a system. The cartridge also has the same  
double-break design as the standard 700-P relay contact cartridge. Relays can be configured with up to a maximum of 12 contacts (only 8  
may be N.C.). Time delay and latching attachments are compatible with master cartridges.  
Heavy Duty Control 700-PHDKIT contact cartridges provide (35 A) switching capability through tandem contact cartridges. A jumper  
allows two (20 A) master contact cartridges to be connected in parallel. A maximum of six poles can be configured in a relay, only four of  
which can be normally closed. Time delay and latch attachments are available.  
Low Energy Control Logic Reed 700-PLRKIT contact cartridges provide switching to 200 mA @ 30 VDC. These contacts are matched  
with standard control (10 A) contact cartridges for low energy switching applications.  
Overlapping Contact 700-POLKIT contact cartridges provide (10 A) switching capabilities with the same rating as the standard contact.  
These cartridge used in pairs operate with the N.O. contact closing before the N.C. contact opens on pick-up and vice versa on the drop-  
out.  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
151  
Relay and Timer Specifications  
AC-Operated Relays - In-stock Contact Configurations  
Contacts  
Open Type, DIN Rail, or Relay Rail Mount (700-MP)  
120V AC 240V AC 480V AC  
Contact Arrangement  
and Markings  
Photo  
N.O.(1)  
4-Pole  
Relay  
0
700-P000A1  
4-Pole  
Relay  
2
4
700-P200A1  
700-P400A1  
700-P800A1  
700-P1200A1  
4-Pole  
Relay  
700-P400A2  
700-P400A4  
8-Pole  
Relay  
8
12-Pole  
Relay  
12  
(1) Factory assembled N.O. contacts can be easily to N.C. in the field.  
DC-Operated Relays - In-stock Contact Configurations  
Contacts  
Open Type Relay Rail Mount (2)  
Contact Arrangement  
and Markings  
Photo  
24V DC  
120V DC  
Cat. No.  
(1)  
N.O.  
Cat. No.  
4-Pole  
Relay  
0
4
700DC-P000Z24  
700DC-P400Z24  
4-Pole  
Relay  
700DC-P400Z1  
8-Pole  
Relay  
8
700DC-P800Z24  
(1) Factory assembled N.O. contacts can be easily to N.C. in the field.  
(2) For DIN Rail mounting, order Cat. No. 700-DRA.  
152  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Base Blank Relay - Factory Assembled  
Photo  
Type of Control Circuit  
Cat. No.  
AC  
700-P000⊗  
DC  
700DC-P000⊗  
AC Coil Voltage Code  
Hz  
50  
60  
24  
A24  
110  
A1  
115-120  
200-208  
230-240  
277  
460-480  
575-600  
A4  
A1  
A20  
A2  
A27  
A6  
DC Coil Voltage Code  
24  
48  
72  
Z72  
115-125  
Z1  
230-250  
Z2  
575-600  
Z6  
Z24  
Z48  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
153  
Relay and Timer Specifications  
Master (20 A) and Heavy Duty (35 A) Contact Cartridge Options  
Follow this process to order a relay that utilizes: 20 A master contact cartridges or 35 A heavy duty contact cartridges.  
Base Blank Relay  
Base Blank Relay  
+
Cartridge Kit  
+
Adder Decks  
+
Coil  
Type of Control Circuit  
Cat. No.  
AC  
700-P000A1  
DC  
700DC-P000Z24  
+
Contact Cartridge Kits  
Continuous Carrying Current  
[A]  
Photo  
Description  
Contents  
Cat. No.  
Master Contact  
Cartridge  
AC Rating Twice NEMA  
A600  
4 Master Cartridges (Cat. No. 700-CPM)  
20  
35  
700-PMCKIT  
DC Rating NEMA N150 P600  
4 Master Cartridges and two sets of jumper terminals, rating  
label (makes two 35 A poles)  
Heavy Duty Contact Kit  
700-PHDKIT  
+
Adder Decks  
Do you have more than four circuits or more than two 35 A circuits in the relay?  
Adder Decks Required  
Cat. No.  
Device Description  
Additional Cartridge Kits Required  
8 Pole Device  
700-PB00  
1 additional kit  
700-PB00  
700-PC00  
(Qty 1 of each)  
12 Pole Device  
2 additional kits  
EXAMPLE Heavy Duty circuit (35 A) application that requires 4 circuits and 240 AC control circuit:  
Base Unit: Cat. No. 700-P000A1  
Cartridge Kits: Cat. No. 700-PHDKIT - Qty 2 (Each kit makes two circuits)  
Adder Deck: Cat. No. 700-PB00  
Coil: Cat. No. PA254  
IMPORTANT If required, see Operating Coils for coil selection.  
154  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Logic Reed and Overlapping Contact Cartridge Option  
Follow this process to order a relay that utilizes: low energy contact cartridges or overlapping late make or late break cartridges.  
Base Blank Relay  
Base Blank Relay  
+
Cartridge Kit  
+
Adder Decks  
+
Coil  
Type of Control Circuit  
Cat. No.  
AC  
700-P000A1  
DC  
700DC-P000Z24  
+
Contact Cartridge Kits  
Continuous Carrying Current  
[A]  
Photo  
Description  
Contents  
Cat. No.  
Logic Reed Cartridge for 2 Logic Reed Cartridges (Cat. No. 700-CPR)  
Low Energy Circuits  
500 mA 150V AC  
200 mA 30V DC  
700-PLRKIT  
150V AC 500 mA 25 VA  
Max. 30V DC 200 mA  
6W Max.  
2 Standard Cartridges (Cat. No. 700-CP1)  
10  
10  
Overlap Contact  
Cartridges  
Overlapping  
4 Overlapping Cartridges (Cat. No. 700-CP11Z)  
700-POLKIT  
Used in pairs. N.O. contact  
closes before N.C. contact  
opens on pick-up and vice  
versa on drop-out.  
+
Adder Decks  
Do you have more than four circuits or more than two 35 A circuits in the relay?  
Adder Decks Required  
Cat. No.  
Device Description  
Additional Cartridge Kits Required  
8 Pole Device  
700-PB00  
1 additional kit  
700-PB00  
700-PC00  
(Qty 1 of each)  
12 Pole Device  
2 additional kits  
EXAMPLE Logic Reed and Overlapping Contact Cartridge Option:  
Low Voltage Circuit 24V DC less than 200 mA  
Base Unit: Cat. No. 700-P000A1  
Cartridge Kits: Cat. No. 700-PLRKIT - Qty 1  
Coil: Cat. No. PA254  
IMPORTANT If required, see Operating Coils for coil selection.  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
155  
Relay and Timer Specifications  
Accessories - 700-P Relays  
Adder Decks  
No. of N.O.  
Contacts  
Continuous Carrying  
Current [A]  
Photo  
Description  
Arrangement  
Cat. No.  
Second Deck (0-pole)  
Second Deck (4-pole)  
0
4
10  
700-PB00  
700-PB40  
Third Deck (0-pole)  
Third Deck (4-pole)  
0
4
0
700-PC00  
700-PC40  
10  
156  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Operating Coils  
Bulletin 700-P Relays — Bulletin 700-PLL-PKLL Mechanical Latch Attachments  
Bulletin 700DC-P  
2…12-pole,  
DC control  
Bulletin 700-P, 2…12-pole, AC control  
Coil  
Bulletin 700-PLL–PKLL AC Mechanical Latch Attachment  
Volts(2)  
60 Hz  
50 Hz  
60 Hz 50 Hz DC  
24  
PA013  
PA407  
PL013  
PL407  
PM714  
PM724  
PM730  
PD714  
48  
PD724  
72  
PD730  
(3)  
110  
PA236  
PL236  
PD733 (100…110)  
115…120(3)  
PA236  
PL236  
PA322  
PL322  
110…115(1)  
Bulletin 700-P  
Operating Coil  
115…125  
120§  
PM735  
PD735  
PA322  
PL322  
130…140  
200…208  
220…230  
230…240  
230…250  
277  
PA249  
PA251  
PA254  
PA339  
PA342  
PL254  
PM748  
PD748  
PA260  
380  
PA354  
PA357  
415  
440…460  
PA360  
460…480  
500  
PA273  
Bulletin 700-PL  
Unlatch Coil and  
Magnet Assembly  
575…600  
PA278  
PD758  
(1) This coil is optimized for 110…115V, 50 Hz applications and will operate satisfactorily at 120V, 60 Hz.  
(2) Coils for AC relays cannot be used in DC relays and vice versa.  
(3) This coil is optimized for 115…120V, 60 Hz applications and will operate satisfactorily at 110V, 50 Hz.  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
157  
Relay and Timer Specifications  
Contact Cartridges (Convertible from N.O. to N.C. and N.C. to N.O.)  
Continuous Carrying  
Current [A]  
Photo  
Description  
Arrangement  
Pkg. Quantity  
Cat. No.  
Standard Contact Cartridge  
AC Rating NEMA A600  
DC Rating NEMA P600  
10  
1
700-CP1  
AC Rating  
10  
5
Overlap Contact Cartridges  
Overlapping  
Used in pairs. N.O. contact closes  
before N.C. contact opens on pick-  
up and vice versa on drop-out. (1)  
NEMA A600  
DC Rating  
2
1
700-CP11Z  
700-CPM  
NEMA P150  
125V DC, 138 VA  
Make and Break  
Master Contact Cartridge  
AC Rating Twice NEMA A600  
DC Rating NEMA N150 P600  
20  
Maximum  
150V AC  
500 mA  
200 mA  
Logic Reed Cartridge for  
Low Energy Circuits  
150V AC 500 mA 25 VA Max.  
30V DC 200 mA  
1
700-CPR  
Maximum  
30V DC  
6W Max. (2)  
(1) Not Direct Drive  
(2) The 700-CPR Logic Reed cartridge must be installed only in the 2nd deck (B1X - B4X, B1Y - B4Y position) or 3rd deck (C1X - C4X, C1Y - C4Y position) of the Bulletin 700 Type P relay. It is not recommended that the 700-CPR cartridge  
be installed in the single deck (A1X - A4X, A1Y - A4Y position) because this may lead to improper operation.  
158  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Electrically Held Relays — Typical Wiring Diagrams  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
159  
Relay and Timer Specifications  
Pneumatic Time-Delay Unit  
Timing Range — 0.1…60 s  
0, 2, or 4 instantaneous contacts  
Two timed contacts — both ON Delay or both OFF Delay  
Convertible from ON Delay to OFF Delay and vice versa  
Standard contact cartridges rated NEMA A600 (AC) and P600 (DC)  
Master contact cartridges rated 2X NEMA A600 (AC) and N150 P600 (DC)  
Open Type  
Without  
No. of Timed Contacts (1)  
Continuous Carrying Current  
Enclosure(2)  
Photo  
Operating Mode  
Arrangement  
Timing Range  
[A]  
N.O.  
N.C.  
Cat. No.  
10  
20  
700-PT  
On-Delay  
Off-Delay  
1
1
0.1…60 s  
700-PKT  
(1) In addition to instantaneous cartridges on the relay  
(2) Mounts on 4-pole Bulletin 700-P or -PK relay or 2-pole Bulletin 700-PH relay.  
Mechanical Latch Units  
Photo  
Description  
Arrangement  
Continuous Carrying Current [A]  
Cat. No.  
No cartridge  
700-PLL⊗  
AC-Operated Latch Units  
10  
700-PLL11⊗  
700-PKLL11⊗  
700DC-PLL⊗  
700DC-PLL10⊗  
20  
No cartridge  
10  
DC-Operated Latch Units  
20  
700DC-PKLL10⊗  
AC Coil Voltage Code  
The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No. 700-PLL⊗  
becomes Cat. No. 700-PLLA1.  
Hz  
50  
60  
24  
110  
A1  
110-115 115-120 120  
200-208 220-230 230-240 277  
347  
380  
415  
440-480 460-480 500  
575-600  
(1)  
(2)  
B24  
A24  
B11  
A2  
A1 (1)  
B11(2)  
(1) Optimized for 115…120V, 60 Hz. Operates satisfactorily at 110V, 50 Hz.  
(2) Optimized for 110…115V, 50 Hz. Operates satisfactorily at 120V, 60 Hz.  
DC Coil Voltage Code  
The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No. 700DC-PLL⊗  
becomes Cat. No. 700DC-PLLZ24.  
24  
48  
64  
72  
115-125  
230-250  
575-600  
Z24  
Z48  
Z72  
Z1  
Z2  
Z6  
160  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Accessories  
Relays per  
Strip  
Photo  
Description  
Pkg. Quantity  
Cat. No.  
4
8
5
5
5
700-MP4  
Relay Rail  
700-MP8  
Simplifies panel layout. These indexed strips are easily cut to the  
required length and bolted, riveted, or spot-welded in place. Relays are  
installed adjacent to one another on the mounting strip with the  
captive mounting screws provided. Rows of relays on Relay Rail form  
their own wiring trough.  
12  
700-MP12  
Can be used with the following relays: 700P, 700DC-P, 700S-P, 700N,  
700-R, 700-RTC  
16  
5
700-MP16  
700-DRA  
DIN Rail Adapter  
Can be used with the following relays:  
Bulletin 700-P, 700DC-P, 700S-P, 700-N, 700-R, 700-RTC  
1
DIN (#3) symmetrical hat rail  
35 x 7.5 x 1 m  
10  
199-DR1  
Type 1 Enclosure — Use for all Bulletin 700-P relays except 10- and 12-pole DC relays  
1
1
700-N31  
700-N39  
or 6-pole DC Bulletin 700-PH relays.  
Type 4/4X Enclosure — For 2- and 4-pole Bulletin 700-P, -N, and -R relays and 2-pole  
heavy duty relays.  
Type 7 & 9 Enclosure — For 2- and 4-pole Bulletin 700-P, -N, and -R relays and 2-pole  
heavy duty relays. 1 conduit hub; top and bottom.  
1
700-N33  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
161  
Relay and Timer Specifications  
Accessories  
Photo  
Description  
Pkg. Quantity  
Cat. No.  
Mountingbehind  
relay  
1
1
700-N5  
Surge Suppressors (RC Circuit) — Surge suppressors reduce the high  
transient voltages generated when the coil circuit is opened. These suppressors  
can be used with Bulletin 700-P, -PH, -PK, and -N relays, and other  
electromechanical devices. They contain a resistor and capacitor. Maximum  
ratings: 150V, AC or DC, 35 VA. Cat. No. 700-N5 requires 1 in. additional depth of  
enclosure.  
Mounting on coil  
terminal  
700-N24  
Surge Suppressor  
24…48V AC/DC  
1
1
199-FSMA9  
When the circuit to a DC operating coil is opened, the inductive energy stored in  
the coil can generate very high transient voltages. With the addition of the  
appropriate surge suppressor, the stored energy is absorbed and dissipated  
limiting the voltage spikes. A surge suppressor is not required with AC 700-R or -  
RM relays because the AC operating coil transients are suppressed by a full wave  
rectifier connected to the coil.  
50…120V AC/  
DC  
199-FSMA10  
130…250V AC/  
DC  
1
1
199-FSMA11  
199-FSMZ-1  
Diode Surge Suppressor — for 6…300V DC voltage coils. Used on Bulletin 700-P, -PH, -PK, -N, -F,  
and -R relays.  
35 A Jumper Kit – CSA Approved, UL Listed  
This 35 A Jumper Kit can be used with any Bulletin 700-P and -PK AC or DC relay, Time-Delay relay or  
Latch Unit equipped with 20 A Master Cartridges. It does not require any additional panel space.  
Jumper Kit terminals are designed for one #8 AWG wire or two #10 AWG wires. When connecting the  
two 20 A Master Cartridges in parallel, it is important that they be the same configuration (Normally  
Open or Normally Closed).  
1
700-CPH  
700-N3  
Jumpers can be added to any contact cartridge location on a relay except the two center poles  
because of the wide spacing. An adhesive label is included with each kit listing the contact ratings.  
Jumpers (Not applicable for Bulletin 700-PH or -PK relays) – For connection  
Jumper – For  
outer poles  
between a middle pole and an outer pole on the left or right side of the relay.  
50  
Cat. No.  
700-N3  
Cat. No.  
700-N4  
Jumpers (Not applicable for Bulletin 700-PH or -PK relays) – For connection  
between two middle poles.  
Jumper – For  
middle poles  
700-N4  
Check Out Tool — Mechanically maintains the Bulletin 700-P, -PH, or -PK relay in the energized  
position for troubleshooting purposes.  
700-N23  
1
Adapter Plate — Simplified relay conversion. Allows you to use the existing mounting holes when  
you replace a Bulletin 700-B, -BR, -BX, or -D relay with a Bulletin 700-P, -PH, or -PK relay.  
700-N34  
162  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
IP 2X Finger-Safe Cover Accessories  
Photo  
Description  
Pkg. Quantity  
Cat. No.  
Top Covers (Covering Top Level Contact Screws)  
IP2X Top Cover for 700-P  
1
1
1
1
1
700-PFSC  
Timer Top Cover Kit  
700-PFSTC  
700-PFSLCK  
700-PFSKTC  
700-PFSKLCK  
Latch Top Cover Kit (for Relays with Mechanical Latch Attachment)  
Timer Top Cover Kit, (for Master Cont. Relays with Pneumatic Timer)  
Latch Top Cover Kit (for Master Cont. Relays with Mechanical Latch)  
Deck Covers (Covering all terminals not on top deck, only for multi-deck relays)  
IP2X Deck Cover for all AC & DC Relays in the 700P Range  
Coil Covers  
1
700-PFSDEK  
IP2X Coil Cover for all AC Relays in the 700P Range  
IP2X Coil Cover for all DC Relays in the 700P Range  
1
1
700-PFSACC  
700-PFSDCC  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
163  
Relay and Timer Specifications  
Specifications - 700-P Relays  
Type  
Standard Cartridge  
700-P  
Master Cartridge  
700-PMCKIT  
Heavy duty  
700-PHDKIT  
Bulletin No.  
Electrical  
Contact Rating Continuous  
10 A @ 600V AC ; 5 A @ 600V DC  
NEMA A600  
20 A @ 600V AC; 10 A @ 600V DC  
2 x NEMA A600  
35 A @ 600V AC; 20 A @ 600V DC  
2 x NEMA A600  
AC  
Ratings Make/Break  
DC  
NEMA P600  
N150 P600  
N150 P600  
3 Hp @ 240V AC - N.O.  
2 Hp @ 240V AC - N.O./N.C.  
1 Hp @ 120V AC - N.O./N.C.  
20 A Resistive Heating to 600V AC  
20 A Tungsten Lighting Load to 480V AC  
Cartridge Cat. No. 700-CPM  
Volts DC  
5 Hp @ 240V AC - N.O.  
3 Hp @ 240V AC - N.O./N.C.  
Additional Contact Ratings for  
AC single-phase loads  
2 Hp @ 120V AC - N.O./N.C.  
35 A General Use At 0.75 PF to 600V AC  
35 A Tungsten Lighting Load to 480V AC  
DC Current Ratings Make/Break  
Cartridge Cat. No. 700-CP1  
Cartridge Cat. No. 700-CPH  
Contacts in  
Series  
24  
64  
125  
250 500  
138 135  
600  
24  
64  
125  
250  
500  
600  
24  
64  
125  
250  
500  
600  
480  
W
480  
W
275  
W
120  
W
W
W
DC Switching  
Inductive Load  
1
5 A 2.2 A 1.1 A .55 A .24 A .2 A 10 A 5 A 2.2 A .55 A .24 A .2 A 10 A 5 A 2.2 A .55 A .24 A .2 A  
2
10 A 10 A 5 A  
2 A  
.7 A .5 A 20 A 10 A 5 A  
2 A  
.7 A .5 A 20 A 10 A 5 A  
2 A .7 A .5 A  
3 A 1.5 A 1.0 A  
3
7 A  
3 A 1.5 A 1.0 A  
15 A 7 A  
3 A 1.5 A 1.0 A  
15 A 7 A  
4
10 A 5 A 2.5 A 1.5 A  
85…110%  
80…110%  
85…115%  
60 Hz  
20 A 10 A 5 A 2.5 A 1.5 A  
20 A 10 A 5 A 2.5 A 1.5 A  
85…110%  
AC  
85…110%  
80…110%  
85…115%  
DC  
80…110%  
Coil Voltage Range  
Battery  
85…115%  
50 Hz  
50 Hz  
60 Hz  
50 Hz  
60 Hz  
Inrush  
132VA (2)  
19.3VA (2)  
138VA (2)  
19VA (2)  
12.7VA (2)  
12.7VA (2)  
15.6VA (2)  
5.5VA (2)  
132VA (2)  
19.3 VA (2)  
138VA (2)  
19VA (2)  
132VA (2)  
19.3VA (2)  
138VA (2)  
19VA (2)  
AC  
DC  
Coil  
Sealed  
Consumption  
Inrush  
12.7VA (2)  
12.7VA (2)  
12.7VA (2)  
12.7VA (2)  
Sealed  
Inrush  
15VA (2)  
5.4VA (2)  
5VA (2)  
5.4VA (2)  
15.6VA (2)  
5.5VA (2)  
15VA (2)  
5.4VA (2)  
15.6VA (2)  
5.5VA (2)  
PLL - PKLL  
AC Latch Unit  
Sealed  
Unlatch  
Intermittent  
PT – PKT  
PLL–PKLL  
35VA (2)  
35 W (2)  
35VA (2)  
35 W (2)  
75 ms  
PLL - PKLL  
DC Latch Unit  
Reset Time  
75 ms  
Minimum Pulse  
75 ms  
75 ms  
Mechanical  
Pickup  
AC – 10…20 ms / DC – 30…50 ms  
AC – 10…20 ms / DC – 20…33 ms  
AC – 10…20 ms / DC – 30…50 ms  
AC – 10…20 ms / DC – 20…33 ms  
10 million operations  
AC – 10…20 ms / DC – 30…50 ms  
AC – 10…20 ms / DC – 20…33 ms  
Operating Time  
Mechanical Life  
Dropout  
Construction  
Up to 6 Poles, Convertible to N.O. or N.C.  
(4 N.C. Maximum)  
Contact Arrangement  
Up to 12 Poles, Convertible to N.O. or N.C. (8 N.C. Maximum)  
Contact Material  
Mounting  
Silver Nickel  
Silver Cadmium Oxide  
Silver Cadmium Oxide  
Panel, Strip Mount, or DIN Rail Horizontal Mounting Recommended  
Environmental  
Operating (1)  
Storage  
–20…+65 °C (–4…+149 °F)  
–40…+65 °C (–40…+149 °F)  
–20…+65 °C (–4…+149 °F)  
–20…+65 °C (–4…+149 °F)  
–40…+65 °C (–40…+149 °F)  
Temperature  
–40…+65 °C (–40…+149 °F)  
Wire Terminations  
#18 AWG…(2) #12 AWG  
Wire size per UL/CSA  
Tightening Torque  
Standards Compliance  
Certifications  
8…12 lb•in (0.9…1.4 N•m)  
UL 508, CSA C22.2, No. 14, EN/IEC 60947-1, -5-1  
cULus Listed (File No. E14840, Guide NKCR/NKCR7), CE Marked, ABS  
(1) Temperature inside the panel.  
(2) Average value for all coils within range. For values on a specific coil voltage, contact your local Rockwell Automation sales office or Allen-Bradley distributor.  
164  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
International Symbol for Mechanically Linked Contacts  
Dimensions - 700-P Relays with standard, master contact, or heavy-duty contact cartridge  
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.  
103.43 (4-5/64)  
— 171.68 (6-49/64)  
1/2  
2.77  
(7/64)  
2.77  
(7/64)  
2- and 4-pole 700-P Relay  
Approx Shipping Weight: AC – 0.68 kg (1.5 lb), DC – 1.34 kg (2.95 lb)  
2- and 4-pole 700-P with Pneumatic Time Delay Attachment  
Approx Shipping Weight: AC – 0.85 kg (1.88 lb), DC – 1.5 kg (3.33 lb)  
AC 136.75 (5-25/64)  
171.68 (6-49/64)  
2.77  
(7/64)  
2.77  
(7/64)  
6- and 8-pole 700-P Relay with one -PB adder deck  
Approx Shipping Weight: AC – 0.79 kg (1.75 lb), DC – 1.45 kg (3.20 lb)  
700-P Relay with Mechanical Latch Attachment  
Approx Shipping Weight: AC – 0.97 kg (2.13 lb), DC – 1.62 kg (3.58 lb)  
AC 136.75 (5-25/64)  
Cat. No. 7±±  
#8 Screws  
(Captive)  
2.77  
(7/64)  
700-P Relay, up to 12 poles with -PB and -PC adder decks  
Approx Shipping Weight: AC – 1.02 kg (2.25 lb), DC – 1.68 kg (3.7 lb)  
Relay Rail for 700-P, -N, -NM, -R, -RM, -RT, -RTA Relays  
Secure the mounting strip with two screws at each end relay position.  
Use a minimum of one screw at the 3rd, 5th, 7th, etc., relay positions.  
Alternate between upper and lower horizontal slots.  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
165  
Relay and Timer Specifications  
178.60  
(7-1/32)  
AC – 170.49 (6-23/32)  
DC – 187 (7-25/64)  
700-PS  
Timer  
Cat. No. 700-N31, Type 1 Enclosure for  
700-P, -RTC Relays  
Approximate Shipping Weight: 1.26 kg (2.8 lb)  
700-PS Timer Mounted on a 700-P Relay  
Approximate Shipping Weight: AC – 0.68 kg (1.5 lb) without 700-PS,  
DC – 1.34 kg (2.9 lb) without 700-PS  
12.5  
6.2  
(15/64)  
1.0  
(0.04)  
50  
(1-63/64)  
(1/2)  
5.2  
(13/64)  
3.98  
(0.16)  
35.0  
27.0  
(1.38)  
(1.06)  
7.5  
1000  
(39-3/8)  
2.25  
(0.09)  
0.5  
(.02)  
(0.3)  
0.5  
(.02)  
Cat. No. 199-DR1 DIN Mounting Rail Series B  
Cat. No. 199-DR4 DIN Mounting Rail Series B Has No Mounting Holes  
DIN Rail Adapter  
166  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
700S-P and 700S-PK — Heavy-Duty Safety Control Relays  
Mechanically linked contacts meet IEC 947-5-1-L  
2…12 poles – all mechanically linked  
Red cover for easy identification of safety circuits  
Tamper resistant cover helps prevent changes which could jeopardize safety  
IEC mechanically linked contacts symbol displayed on front  
Visual indication of contact state  
Ideal for use in safety circuits  
700S-P (10 A) Safety Control Relays — AC and DC Coil Voltages  
AC Coils  
Contacts  
24V DC Coils  
Open Type Panel Mount Relay Rail Mount  
Open Type Panel Mount Relay Rail Mount  
Open Type DIN Rail Mount  
N.O.  
3
N.C.  
1
Cat. No.  
Cat. No.  
700S-DCP310Z24  
700S-DCP220Z24  
700S-DCP710Z24  
700S-DCP620Z24  
700S-DCP530Z24  
700S-DCP440Z24  
700S-DCP350Z24  
700S-DCP1020Z24  
Cat. No.  
700S-P310  
700S-P220  
700S-P710  
700S-P620  
700S-P530  
700S-P440  
700S-P350  
700S-P1020  
700S-DCP310DZ24  
2
2
700S-DCP220DZ24  
700S-DCP710DZ24  
700S-DCP620DZ24  
700S-DCP530DZ24  
700S-DCP440DZ24  
700S-DCP350DZ24  
700S-DCP1020DZ24  
7
1
6
2
5
3
4
4
3
5
10  
2
(1)  
AC Coil Voltage Code  
The Cat. No. as listed is incomplete. Select a coil voltage code from the table below to complete the Cat. No. Example: Cat. No. 700S-P310  
becomes Cat. No. 700S-P310A1 for a 120V AC coil.  
[V]  
24  
115-120  
230-240  
460-480  
60 Hz  
A24  
A1  
A2  
A4  
IEC 947-5-1 Annex L has 2 requirements for a relay to meet for mechanically linked contacts:  
1.) If a N.O. contact welds, all the N.C. contacts will remain open and meet a 2500V impulse test.  
2.) If a N.C. contact welds, all the N.O. contacts will remain open and meet a 2500V impulse test.  
700S-P and 700S-DCP relays meet these requirements including the 2500V impulse test.  
The relays shown on this page are shipped from the factory with the 700-CPS safety cartridge installed and cannot be converted to N.O. or N.C. in the Field.  
(1) For other coil voltages, consult your local Rockwell Automation sales office or Allen-Bradley distributor.  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
167  
Relay and Timer Specifications  
700S-PK (20 A) Safety Control Relays  
Contacts  
Coil Voltage  
Cat. No.  
N.O.  
N.C.  
7
1
2
3
4
5
2
1
1
2
3
4
5
2
1
110V AC  
110V AC  
110V AC  
110V AC  
110V AC  
110V AC  
110V AC  
24V DC  
24V DC  
24V DC  
24V DC  
24V DC  
24V DC  
24V DC  
700S-PK710A1  
6
700S-PK620A1  
5
700S-PK530A1  
4
700S-PK440A1  
3
700S-PK350A1  
10  
3
700S-PK1020A1  
700S-PK310A1  
7
700S-DCPK710Z24  
700S-DCPK620Z24  
700S-DCPK530Z24  
700S-DCPK440Z24  
700S-DCPK350Z24  
700S-DCPK1020Z24  
700S-DCPK310Z24  
6
5
4
3
10  
3
168  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Specifications - 700S-P Relays  
Type  
700S-P  
Electrical  
10 A @ 600V AC  
5 A @ 600V DC  
Contact Rating Continuous  
AC  
NEMA A600  
NEMA P600  
10V, 50 mA  
Volts DC  
Ratings Make/ Break  
DC  
Minimum Contact Switching Ratings  
Contacts in Series  
24V  
5 A  
64V  
2.2 A  
10 A  
125V  
1.1 A  
5 A  
250V  
0.55 A  
2 A  
500V  
600V  
0.2 A  
0.5 A  
1.0 A  
1.5 A  
DC  
1
2
3
4
0.24 A  
0.7 A  
1.5 A  
2.5 A  
Switching  
Inductive Load  
10 A  
7 A  
3 A  
10 A  
5 A  
1.5 million operations at 10A break at 120V AC  
14 million operations at 1A break at 120V AC  
6 million operations at 1A break at 24V DC  
Contact Electrical Life— Resistive Loads  
AC  
85…110%  
80…110%  
85…115%  
Coil Voltage Range (1)  
DC  
Battery Charging  
Coil Consumption  
AC  
50 Hz  
132 VA  
19.3 VA  
60 Hz  
138 VA  
19 VA  
Inrush  
Sealed  
Inrush  
Sealed  
12.7 W  
12.7 W  
DC  
Mechanical  
Mechanically Linked Contacts  
All contacts are mechanically linked per IEC 947- 5-1 annex L for 2 to 12 poles  
AC – 10…20 ms  
DC – 30…50 ms  
Pickup  
Operating  
Time  
AC – 10…20 ms  
DC – 20…33 ms  
Dropout  
Mechanical Life  
10 million operations  
Construction  
2…12 Poles, Double Break Contacts  
N.O. or N.C. (8 N.C. Maximum)  
Contact Arrangement  
Contact Material/Design  
Mounting  
Silver Nickel/Bifurcated  
Panel mount or mount on 700-MP Relay or DIN Rail Horizontal Mounting Recommended  
Environmental  
Operating Temperature (2)  
Storage Temperature  
Wire Terminations  
Wire size per UL/CSA  
Tightening Torque  
-20…+65 °C (-4…+149 °F)  
-40…+65 °C (-40…+149 °F)  
#18 AWG…(2) #12 AWG  
8…12 lb•in (0.9…1.4 N•m)  
Standards Compliance  
Certifications  
UL 508, CSA C22.2, No. 14, EN/IEC 60947-1, -5-1  
cULus Listed (File No. E14840, Guide NKCR/NKCR7), CE Marked, ABS  
(1) Coil voltage required for proper operation (percent of rated coil voltage).  
(2) Temperature inside the panel.  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
169  
Relay and Timer Specifications  
Specifications - 700S-PK Relays  
Type  
700S-PK  
Electrical  
20 A @ 600V AC  
10 A @ 600V DC  
Contact Rating Continuous  
AC  
NEMA A600  
NEMA P600  
Ratings Make/ Break  
DC  
3 Hp @ 240V AC - N.O.  
2 Hp @ 240V AC - N.O./N.C.  
Additional Contact Ratings for AC Single-Phase Loss  
1 HP @ 120V AC - N.O./N.C.  
20 A resistive heating to 600V AC  
20 A Tungsten lighting load to 480V AC  
DC Current Ratings Make/Break  
Contacts in Series  
Cartridge Cat. No. 700-CMS  
Volts DC  
24V  
10 A  
20 A  
64V  
5 A  
125V  
2.2 A  
5 A  
250V  
0.55 A  
2 A  
500V  
0.24 A  
0.7 A  
1.5 A  
2.5 A  
600V  
0.2 A  
0.5 A  
1.0 A  
1.5 A  
1
DC  
Switching  
2
10 A  
15 A  
20 A  
3
7 A  
3 A  
4
10 A  
5 A  
85…110%  
80…110%  
85…115%  
AC  
Coil Voltage Range (1)  
DC  
Battery Charging  
50 Hz  
132 VA  
19.3 VA  
60 Hz  
138 VA  
19 VA  
Coil Consumption  
AC  
Inrush  
Sealed  
Inrush  
Sealed  
12.7 W  
12.7 W  
DC  
Mechanical  
All contacts are mechanically linked per IEC 947-5-1 annex L  
for 2 to 12 poles  
Mechanically Linked Contacts  
AC – 10…20 ms, DC – 30…50 ms  
AC – 10…20 ms, DC – 20…33 ms  
Pickup  
Operating Time  
Dropout  
Construction  
2…12 Poles, Double Break Contacts N.O. or N.C. (8 N.C. Maximum)  
Silver Cadmium Oxide  
Contact Arrangement  
Contact Material/Design  
All contacts, are mechanically linked per IEC 947-5-1 Annex L for 2 to 12 poles  
Panel mount or strip mount recommended  
Mechanical (Mechanically-Linked Contacts)  
Mounting  
Environmental  
Operating Temperature (2)  
Storage Temperature  
Wire Terminations  
Wire size per UL/CSA  
Tightening Torque  
-20…+65 °C (-4…+149 °F)  
-40…+65 °C (-40…+149 °F)  
#18 AWG…(2) #12 AWG  
8…12 lb•in (0.9…1.4 N•m)  
Standards Compliance  
UL 508, CSA C22.2, No. 14, EN/IEC 60947-1, -5-1  
Certifications  
cULus Listed (File No. E14840, Guide NKCR/NKCR7), CE Marked, ABS  
(1) Coil voltage required for proper operation (percent of rated coil voltage).  
(2) Temperature inside the panel.  
170  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Dimensions - 700S-P Relays  
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.  
103.43 (4-5/64)  
AC 136.75 (5-25/64)  
1/2  
2.77  
(7/64)  
2.77  
(7/64)  
2- and 4-pole 700S-P Relay  
Approximate Shipping Weight: AC – 0.68 kg (1.5 lb), DC – 1.34 kg (2.95 lb)  
6- and 8-pole 700S-P Relay  
Approximate Shipping Weight: AC – 0.79 kg (1.75 lb), DC – 1.45 kg (3.20 lb)  
170.10 (6-45/64)  
Cat. No. 7±±  
#8 Screws  
(Captive)  
2.77  
(7/64)  
10- and 12-pole 700S-P (Captive)  
Relay Rail  
Approximate Shipping Weight: AC – 1.02 kg (2.25 lb), DC – 1.68 kg (3.7 lb)  
12.5  
(1/2)  
1.0  
(0.04)  
6.2  
(15/64)  
50  
(1-63/64)  
5.2  
(13/64)  
35.0  
27.0  
(1.38)  
(1.06)  
7.5  
1000  
(0.3)  
(39-3/8)  
DIN Rail  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
171  
Relay and Timer Specifications  
700-N Industrial Relays  
Contact cartridges convertible from N.O. to N.C. and vice versa  
NEMA A300 AC  
24…250V AC coils  
Pneumatic timing unit  
Solid-state timing unit  
Overlap contacts  
Logic reed contacts  
4-…8-pole  
AC-Operated Relays  
Contacts  
N.O.  
Open Type  
Cat. No.  
Photo  
Contact Arrangement  
N.C.  
4
700-N400⊗  
Type NM Relay  
2 Poles§  
2
700-NM200⊗  
AC Coil Voltage Code  
The Cat. No. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 700-N200⊗  
becomes Cat. No. 700-N200A24 for 24V 60 Hz. For other coil voltages, contact your local Rockwell Automation sales office or Allen-Bradley  
distributor.  
[V]  
24  
110  
120  
208  
220  
240  
50 Hz  
60 Hz  
A1  
A1  
A2  
A2  
A24  
A20  
NORMALLY CLOSED CONTACTS: Listed relays are supplied with all contacts normally open. These contacts can be readily converted to normally closed in  
the field.  
OVERLAP CONTACTS: Overlap contacts (normally open contact closes before the normally closed contact opens) can be supplied. See for information on  
kits for field installation of overlap contact cartridges.  
IMPORTANT  
Location of contacts in 2-pole relays  
Permanent Magnet Latch AC Relay. Minimum Operating Time - Type NM - For reliable operation, power to the latch circuit must be maintained for a  
minimum time of 75 milliseconds and power to the unlatch circuit must be maintained for minimum time of 50 milliseconds.  
172  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Operating Coils  
700-N Relay • 2-…8-Pole  
Photo  
Coil Voltage  
60 Hz  
50 Hz  
84AB28  
84AB86  
24  
84AB27  
84AB01  
84AB86  
84AB113  
84AB06  
84AB83  
110  
120  
208  
220  
240  
84AB83  
700-NT Pneumatic Timing Unit  
Timed  
Contact  
Contacts  
Arrangement  
Open Type  
Photo  
Description  
N.O.  
N.C.  
Cat. No.  
ON-Delay mode is  
standard. Timer is  
easily converted to  
OFF-Delay mode.  
Timing Unit Only  
(for 700-N, 2…4-pole)  
1
1
700-NT  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
173  
Relay and Timer Specifications  
Specifications - 700-N Relays  
Attribute  
Bul. 700-N  
Bul. 700-NT  
Electrical Ratings  
Rated Thermal Current Ith  
Rated Insulation Voltage  
Contact Rating  
10 A  
300V  
10 A @ 300V AC, NEMA A300  
AC  
DC  
85…110%  
80…110%  
Coil Voltage Range  
Coil Consumption  
50 Hz  
AC  
60 Hz  
Inrush  
Sealed  
120 VA  
24 VA  
133 VA  
20 VA  
AC  
Mechanical  
Pickup  
14 ms  
13 ms  
Max. Operating Time  
Drop Out  
Timing Range  
Repeat Accuracy  
Reset Time  
0.2…60 s  
15% of setting  
75 ms  
On-Delay — convertible to OFF Delay, up to 2 poles  
convertible to N.O. or N.C.  
Timing Mode  
Construction  
Contact Arrangement  
Contact Material  
Mounting  
Up to 8 Poles, Convertible to N.O. or N.C.  
Silver  
Silver  
Panel or strip mount Horizontal mounting recommended  
On relay only  
Environmental  
Operating  
Storage  
–20…+40 °C (–4…+104 °F)  
Ambient Temperature (Outside  
Enclosure)  
–40…+60 °C (–40…+140 °F)  
Operating Temperature Rise (Inside Enclosure)  
Wire Terminations  
+25 °C Max  
Wire size per UL/CSA  
Tightening Torque  
#18 AWG…(2) #12 AWG  
8…12 lb•in. (0.9…1.4 N•m)  
Standards Compliance  
UL 508, CSA C22.2, No. 14  
Certifications  
cULus Listed (File No. E14840, Guide NKCR/NKCR7)  
174  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Dimensions - 700-N Relays  
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.  
Type of Relay  
No.  
of  
Poles  
Open Type  
Approx  
. Ship.  
Wt. kg  
(lbs.)  
Type 1  
General Purpose Enclosure  
Approx  
Without Enclosure  
. Ship.  
Wt. kg  
(lbs.)  
Drawing  
Number  
A
B
High  
C
D
A
Wide  
B
C
D
E
Wide  
Deep  
High  
Deep  
185.74 103.19  
57.15  
88.90  
82.55  
79.38  
0.68  
107.95  
146.05  
85.73  
1.59  
700  
700  
700  
700  
2…4  
6…8  
2…4  
2…4  
1
2
3
3
(7-5/  
16)  
(4-1/  
16)  
(2-1/4) (3-1/2) (3-1/4) (3-1/8) (1-1/2) (4-1/4)  
(5-3/4) (3-3/8) (3-1/2)  
N
N
106.36  
(4-3/  
16)  
112.71  
(4-7/  
16)  
57.15  
(2-1/4) (3-1/2)  
88.90  
79.38  
(3-1/8) (1-3/4)  
0.79  
228.60 120.65 206.38  
92.08  
2.27  
(5)  
(9)  
(4-3/4) (8-1/8) (3-5/8)  
138.11  
(5-7/  
16)  
57.15  
(2-1/4) (3-1/2)  
88.90  
79.38  
(3-1/8)  
0.91  
(2)  
with Pneumatic  
Timer  
N
160.34  
(6-5/  
16)  
57.15  
(2-1/4) (3-1/2)  
88.90  
79.38  
(3-1/8) (2-1/4)  
1.02  
with Solid-State  
Timer  
C
A
A
C
A
C
D
B
B
D
D
B
Drawing Number 1  
Drawing Number 2  
Drawing Number 3  
178.60  
(7-1/32)  
Cat. No. 7±±  
#8 Screws  
(Captive)  
12.5  
(1/2)  
1.0  
(0.04)  
6.2  
(15/64)  
50  
(1-63/64)  
5.2  
(13/64)  
35.0  
(1.38)  
27.0  
(1.06)  
7.5  
(0.3)  
1000  
(39-3/8)  
3.98  
(0.16)  
2.25  
(0.09)  
0.5  
(.02)  
DIN Rail Adapter  
0.5  
(.02)  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
175  
Relay and Timer Specifications  
700-R Sealed Switch Relays  
Sealed contacts  
Extremely long mechanical and electrical life  
Hazardous locations Class 1, Div 2 Groups A, B, C, D  
Harsh environments  
Suitable for applications with shock and vibration  
High reliability circuit integrity  
Electrically Held  
No.  
of  
AC-Operated Relay Only  
Open Type  
Cat. No.  
DC-Operated Relay Only  
Open Type  
Cat. No.  
Contacts  
Contact Arrangement  
and Markings‡  
Poles  
N.O.  
0
N.C.  
0
0
1
2
0
1
2
3
4
0
1
2
3
4
5
6
0
1
2
3
4
5
6
7
8
0
Relay without Contact  
700-R000⊗  
700-R200⊗  
700-R110⊗  
700-R020⊗  
700-R400⊗  
700-R310⊗  
700-R220⊗  
700-R130⊗  
700-R040⊗  
700-R600 ⊗  
700-R510 ⊗  
700-R420 ⊗  
700-R330 ⊗  
700-R240 ⊗  
700-R150 ⊗  
700-R060 ⊗  
700-R800 ⊗  
700-R710 ⊗  
700-R620 ⊗  
700-R530 ⊗  
700-R440 ⊗  
700-R350 ⊗  
700-R260 ⊗  
700-R170 ⊗  
700-R080 ⊗  
700DC-R000⊗  
700DC-R200⊗  
700DC-R110⊗  
700DC-R020⊗  
700DC-R400⊗  
700DC-R310⊗  
700DC-R220⊗  
700DC-R130⊗  
700DC-R040⊗  
700DC-R600 ⊗  
700DC-R510 ⊗  
700DC-R420 ⊗  
700DC-R330 ⊗  
700DC-R240 ⊗  
700DC-R150 ⊗  
700DC-R060 ⊗  
700DC-R800 ⊗  
700DC-R710 ⊗  
700DC-R620 ⊗  
700DC-R530 ⊗  
700DC-R440 ⊗  
700DC-R350 ⊗  
700DC-R260 ⊗  
700DC-R170⊗  
700DC-R080 ⊗  
2
2
4
1
0
4
3
2
1
0
6
5
4
6
3
2
1
0
8
7
6
5
8
4
3
2
1
0
‡ Arrangement displays all N.O. contacts.  
Location of contacts in 6-pole relays.  
Δ Polarity must be observed for DC voltage (700 DC) relays.  
Location of contacts in 2-pole relays.  
Coil Voltage Code  
The Cat. No. as listed is incomplete. Select a voltage code from the table below to complete the Cat. No. Example: Cat. No. 700-R000becomes  
Cat. No. 700-R000A24.  
Coil Volts  
Type of Relay  
[V]  
24  
48  
110  
115-125  
120  
220  
230-250  
240  
Z48  
A1  
Z1  
A1  
A2  
Z2  
A2  
AC  
DC  
25, 50, 60 Hz  
A24  
Z24  
176  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Accessories - 700-R Relays  
Pkg.  
Qty.  
Photo  
Description  
Cat. No.  
Relay Rail  
4 Relays per Strip  
8 Relays per Strip  
12 Relays per Strip  
5
5
5
700-MP4  
700-MP8  
700-MP12  
Simplifies panel layout. These indexed strips are  
easily cut to the required length and bolted,  
riveted, or spot-welded in place. Relays are  
installed adjacent to one another on the  
mounting strip with the captive mounting  
screws provided. Rows of relays on Relay Rail  
form their own wiring trough.  
16 Relays per Strip  
5
700-MP16  
Can be used with the following relays: 700P,  
700DC-P, 700S-P, 700N, 700-R, 700-RTC  
DIN (#3) symmetrical hat rail  
35 x 7.5 x 1 m  
10  
199-DR1  
DIN Rail Adapter  
Can be used with the following relays:  
700-P, 700DC-P, 700S-P, 700-N, 700-R, 700-RTC  
1
700-DRA  
Front Deck with one N.O. Contact  
Cartridge (700-R Relay)  
1
1
1
700-RA10  
700-RA01  
700-RB10  
Front Deck with one N.C. Contact  
Cartridge (700-R Relay)  
Front Deck  
A front deck can be attached to 700 2-, 3-, or 4-  
pole AC and DC Type R relays.  
Front Deck with one N.O. Contact  
Cartridge (700-RM Relay)  
Front Deck with one N.C. Contact  
Cartridge (700-RM Relay)  
1
700-RB01  
Contact Cartridges  
N.O. Contact Cartridge - Green  
1
1
700-CR5  
700-CR6  
These cartridges are used to increase the number (700-R Relay)  
of poles of a relay. A dummy cartridge is also  
N.C. Contact Cartridge - Yellow  
(700-R Relay)  
available to fill empty space not occupied by a  
contact cartridge.  
“DUMMY”Cartridge - Black  
(700-R Relay)  
1
700-CR9  
Cat. No.  
700-CR5  
Cat. No.  
700-CR6  
Cat. No.  
700-CR9  
12V DC (700-R Relay)  
24V DC (700-R Relay)  
48V DC (700-R Relay)  
115…125V DC (700-R Relay)  
1
1
1
1
Surge Suppressor  
199-FSMA9  
199-FSMA10  
199-FSMA11  
When the circuit to a DC operating coil is opened,  
the inductive energy stored in the coil can  
generate very high transient voltages. With the  
addition of the appropriate surge suppressor, the  
stored energy is absorbed and dissipated  
limiting the voltage spikes. A surge suppressor is  
not required with AC 700-R relays because the AC  
operating coil transients are suppressed by a full  
wave rectifier connected to the coil.  
230…250V DC (700-R Relay)  
1
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
177  
Relay and Timer Specifications  
Specifications - 700-R  
Application Data – Because of the inherent characteristics of this device, the normally open contacts may close before the normally closed contacts  
open on energization and the normally closed contacts may close before the normally open contacts open on de-energization.  
Ratings  
AC Voltage  
DC Voltage  
NEMA Rating  
Designation  
Voltage  
Make  
Break  
Continuous NEMA Rating  
Volts DC  
Make/Break Continuous  
Carrying  
Designation  
Carrying  
Current [A]  
Current [A]  
120V  
240V  
480V  
600V  
30  
15  
3
B300  
C600  
Up to 300V AC  
5
46…300  
5…46  
138 VA  
3 A  
5
5
1.5  
NEMA P300  
3.75  
3.0  
0.375  
0.30  
Above 300V AC  
2.5  
Maximum Allowable Off-State Leakage Current  
Voltage  
Maximum Off-State Leakage  
Current [mA]  
Type R  
24V DC  
24V AC  
120V AC  
23  
23  
5
Relay Data  
Type  
Contact Arrangement  
700-R  
Up to 8 poles, available in any combination of N.O. or N.C. contacts  
W (tungsten in a controlled gas atmosphere)  
Contact Material  
24…250V AC  
24…250V DC  
Coil Voltage Range  
Sealed  
5.5 VA, 50/60 Hz  
5.5 W DC  
Voltage Range: –15… +10%  
Coil Power  
5.5 VA, 50/60 Hz  
5.5 W DC  
Inrush  
30 ms  
30 ms  
Pickup Time  
Dropout Time  
–40…+60 °C (–40…+140 °F)  
Panel mount  
Operating Temperature  
Mounting  
Haz. Loc. Ratings  
Standards Compliance  
Certifications  
Class I, Division 2, Groups A, B, C, and D  
ISA 12.12, CSA C22.2, No. 213, EN/IEC 60947-1, -5-1  
cULus Listed (File No. E10314, Guide NOIV/NOIV7), CE Marked  
178  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
700-R Operating Coils  
Coil Volts  
700-R  
2-…8-Pole AC  
700-R  
2-…8-Pole DC  
60 Hz  
77AB27  
77AB134  
77AB86  
50 Hz  
77AB27  
77AB134  
77AB86  
24  
48  
77D152  
77D166  
110  
115…125  
120  
77D155  
77AB86  
77AB86  
208  
220  
77AB83  
77AB83  
77AB83  
77AB83  
240  
230…250  
77D156  
Dimensions - 700-R  
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.  
700-R Relays  
Type of Relay  
No. of  
Poles  
Open Type  
Approx  
. Ship  
Wt. [kg  
(lb)]  
Type 1  
General Purpose Enclosure  
Approx  
. Ship  
Wt. [kg  
(lb)]  
Without Enclosures  
Drawing  
Number  
A
B
High  
C
D
A
Wide  
B
C
D
E
Wide  
Deep  
High  
Deep  
55.56  
(2-3/  
16)  
185.74 103.19  
88.90  
92.25  
79.38  
0.91  
(2)  
104.78  
(4-1/8)  
146.05  
85.73  
1.81  
(4)  
2…4  
5…8  
1
2
(7-5/  
16)  
(4-1/  
16)  
(3-1/2) (3-3/8) (3-1/8)  
(5-3/4) (3-3/8)  
700 and  
700DC  
R
55.56  
(2-3/  
16)  
112.71  
(4-7/  
16)  
88.90  
111.13  
79.38  
1.02  
228.60 120.65 206.38  
92.08  
2.49  
(5)  
(3-1/2) (4-3/8) (3-1/8) (2-1/4)  
(9)  
(4-3/4) (8-1/8) (3-5/8)  
A
C
C
A
B
D
B
D
700-R400…  
700-R800…  
A
E
C
3.98  
(0.16)  
B
D
2.25  
(0.09)  
0.5  
(.02)  
0.5  
(.02)  
Type 1 Enclosure  
DIN Rail Adapter  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
179  
Relay and Timer Specifications  
Cat. No. 7±±  
Secure the mounting strip with 2  
screws at each end relay position. Use  
a minimum of one screw at the 3rd,  
5th, 7th, etc., relay positions. Alternate  
between upper and lower horizontal  
slots.  
#8 Screws  
(Captive)  
Relay Rail  
12.5  
6.2  
(15/64)  
1.0  
(0.04)  
50  
(1-63/64)  
(1/2)  
5.2  
(13/64)  
35.0  
27.0  
(1.38)  
(1.06)  
7.5  
1000  
(0.3)  
(39-3/8)  
Cat. No. 199-DR1 DIN Mounting Rail Series B  
180  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
700-RTC — Solid-State Timing Relay  
Timing functions  
8 ON-delay  
8 OFF-delay  
Timing ranges  
Seconds: 0.05…2, 0.2…8, 0.4…30, 2…120  
Minutes: 0.015…1, 0.06…4, 0.25…16 and 1…64  
AC, 50/60 Hz or DC  
600V AC maximum  
300V DC maximum  
Relays with fixed time delay  
Sealed contacts  
Harsh environments  
Hazardous locations Class I, Div. 2, Groups A, B, C and D  
700-RTC Relay with Adjustable Time Delay – Relays with Provision for Instantaneous Contacts  
Relays listed below have slots for two timed contacts and two instantaneous contacts. Unused slots are equipped with removable dummy cartridges.  
Number of Contact Cartridges  
Open Type Without Enclosure  
Cat. No.  
Instantaneous  
Timed  
N.O.  
0
Total  
N.O.  
N.C.  
N.C.  
0
1
0
0
0
700-RTC00000⊗  
0
0
0
1
0
0
1
0
0
1
2
0
1
1
2
0
0
1
1
0
0
0
0
0
0
1
0
0
1
0
0
0
1
1
0
0
2
1
1
0
2
1
1
0
2
1
1
1
0
0
0
2
1
2
1
1
0
1
1
0
0
0
0
0
1
0
0
0
1
1
1
2
0
0
0
0
1
1
0
1
1
2
1
2
700-RTC00100⊗  
700-RTC00010⊗  
700-RTC00200⊗  
700-RTC10100⊗  
700-RTC01100⊗  
700-RTC00110⊗  
700-RTC10010⊗  
700-RTC01010⊗  
700-RTC00020⊗  
700-RTC10200⊗  
700-RTC20100⊗  
700-RTC01200⊗  
700-RTC11100⊗  
700-RTC10110⊗  
700-RTC20010⊗  
700-RTC02100⊗  
700-RTC01110⊗  
700-RTC11010⊗  
700-RTC10020⊗  
700-RTC02010⊗  
700-RTC01020⊗  
2
3
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
181  
Relay and Timer Specifications  
Number of Contact Cartridges  
Open Type Without Enclosure  
Cat. No.  
Instantaneous  
Timed  
N.O.  
Total  
N.O.  
N.C.  
N.C.  
2
1
2
0
1
2
1
0
0
0
1
0
2
1
0
1
2
2
2
2
1
2
1
0
0
1
0
0
0
1
0
1
2
2
1
2
700-RTC20200⊗  
700-RTC11200⊗  
700-RTC20110⊗  
700-RTC02200⊗  
700-RTC11110⊗  
700-RTC20020⊗  
700-RTC11020⊗  
700-RTC02110⊗  
700-RTC02020⊗  
4
Coil Voltage Code  
The Cat. No. as listed is not complete. Select a voltage code from the table below to complete the Cat. No. Example: Cat. No. 700-RTC00100⊗  
becomes Cat. No. 700-RTC00100U24. For other voltages consult your local Rockwell Automation sales office or Allen-Bradley distributor.  
[V]  
24V DC, 24V AC  
120V DC, 110/120V AC  
50/60 Hz  
U24  
U1  
700-RTC Relays with Fixed Time Delay— Relays with Provision for Instantaneous Contacts  
Relays listed below have slots for two timed and two instantaneous contacts. Unused slots are equipped with removable dummy cartridges.  
Number of Contact Cartridges  
Open Type Without Enclosure  
Cat. No.  
Timed  
Instantaneous  
N.O.  
Total  
N.O.  
N.C.  
N.C.  
0
1
0
1
0
2
1
1
1
0
0
0
2
1
2
1
1
0
1
1
0
0
0
0
0
0
1
0
0
0
1
1
1
2
0
0
0
0
1
1
0
1
1
2
1
2
0
0
0
0
1
0
0
1
0
0
1
2
0
1
1
2
0
0
1
1
0
0
0
0
0
0
0
1
0
0
1
0
0
0
1
1
0
0
2
1
1
0
2
1
700-RTC00#0⊗  
700-RTC10#0⊗  
700-RTC20#0⊗  
700-RTC40#0⊗  
700-RTC11#0⊗  
700-RTC12#0⊗  
700-RTC30#0⊗  
700-RTC21#0⊗  
700-RTC22#0⊗  
700-RTC50#0⊗  
700-RTC41#0⊗  
700-RTC14#0⊗  
700-RTC42#0⊗  
700-RTC13#0⊗  
700-RTC31#0⊗  
700-RTC24#0⊗  
700-RTC15#0⊗  
700-RTC32#0⊗  
700-RTC23#0⊗  
700-RTC51#0⊗  
700-RTC25#0⊗  
700-RTC52#0⊗  
2
3
182  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Number of Contact Cartridges  
Open Type Without Enclosure  
Cat. No.  
Timed  
Instantaneous  
N.O.  
Total  
N.O.  
N.C.  
N.C.  
2
2
1
2
0
0
1
0
1
2
1
2
2
2
1
2
0
1
2
0
1
0
0
1
0
2
1
0
2
1
2
700-RTC44#0⊗  
700-RTC43#0⊗  
700-RTC34#0⊗  
700-RTC45#0⊗  
700-RTC33#0⊗  
700-RTC54#0⊗  
700-RTC35#0⊗  
700-RTC53#0⊗  
700-RTC55#0⊗  
4
1
0
1
0
0
# Operating Mode  
Replace the # in the cat. no. with the appropriate letter and numbers to indicate the operating mode and the fixed time delay value. Refer to  
operating mode table below.  
Digit  
Operating Mode  
On-Delay – s  
Fixed Time Delay  
S
Z
Y
I
Seconds –Two digits indicating the fixed time delay in seconds.  
Three digits indicating the fixed time delay (first digit indicates seconds, next  
two digits indicate 1/100 seconds).  
Off-Delay – s  
On-Delay – Min.  
Off-Delay – Min.  
Minutes –Two digits indicating the fixed time delay in minutes.  
Three digits indicating the fixed time delay (first digit indicates minutes, next  
two digits indicate 1/100 minutes).  
EXAMPLE Cat. No. 700-RTC00Y200U1 is for a relay without contact cartridges. “Y20”indicates an On-Delay timer with a 20 minute fixed  
time delay. This is astandard relay.Order the contact cartridges separately.  
Cat. No. 700-RTC42S020U1 is for a relay with 2 N.O. cartridges in the timed position and 1 N.C. cartridge in the instantaneous  
position. “S02”indicates an On-Delay timer with a 2 second fixed time delay.  
Coil Voltage Code  
The cat. no. as listed is not complete. To complete the cat. no., add a coil code selected from the table below.  
[V]  
24V DC, 24V AC  
120V DC, 110/120V AC  
50/60 Hz  
U24  
U1  
Accessories - 700-RTC Relays  
Description  
Cartridge Type  
Color  
Cat. No.  
Photo  
N.O.  
Grey  
700-CRT5  
Contact Cartridges – These cartridges are used to add contacts  
to timing relays having unused slots. The N.O., N.C., and Dummy  
cartridges are interchangeable and can be used in timed or  
instantaneous contact slots. Dummy cartridges should be placed in  
unused cartridge slots to guard against entrance of foreign  
material.  
N.C.  
Orange  
700-CRT6  
700-CR9  
Cat. No.  
700-CRT5  
Cat. No.  
700-CRT6  
Cat. No.  
700-CR9  
Dummy Cartridge Black  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
183  
Relay and Timer Specifications  
Description  
Cartridge Type  
Color  
Cat. No.  
Photo  
Type 1 Enclosure — Use for all 700-P relays except 10- and 12-pole DC relays or 6-pole DC 700-PH  
relays.  
700-N31  
Relays per Strip  
Pkg. Quantity  
Relay Rail  
700-MP4  
Simplifies panel layout. These indexed strips are easily cut to the  
required length and bolted, riveted, or spot-welded in place.  
Relays are installed adjacent to one another on the mounting strip  
with the captive mounting screws provided. Rows of relays on  
Relay Rail form their own wiring trough.  
4
5
5
5
5
8
700-MP8  
700-MP12  
700-MP16  
12  
16  
Can be used with the following relays: 700P, 700DC-P, 700S-P,  
700N, 700-R, 700-RTC  
DIN (#3) symmetrical hat rail  
35 x 7.5 x 1 m  
10  
199-DR1  
DIN Rail Adapter  
Can be used with the following relays:  
700-P, 700DC-P, 700S-P, 700-N, 700-R, 700-RTC  
1
700-DRA  
Specifications - 700-RTC Relays  
Voltage and Power Requirements  
AC Voltage  
+10ꢀ –15ꢀ 50/60 Hz  
Total Power Required  
Initiate Terminal Power  
Maximum Allowable  
Leakage Current  
Coil Code  
24V AC  
8 VA  
9 VA  
4 VA  
4 VA  
10 mA  
U24  
U1  
110/120V AC  
2.4 mA  
DC Voltage  
+10ꢀ –20ꢀ  
Total Power Required  
Initiate Terminal Power  
Maximum Allowable  
Leakage Current  
Coil Code  
24V DC  
10 W  
11 W  
5 W  
5 W  
10 mA  
U24  
U1  
120V DC  
2.4 mA  
Type  
700-RTC  
NEMA B600 600V AC, 5 A  
NEMA P300 300V DC, 5 A  
Contact Rating  
1…4 poles. Max. of 2 timed and 2 instantaneous.  
Available in any combination of N.O. and N.C. contacts  
Contact Arrangement  
Contact Material  
Operating Mode  
W (tungsten in a controlled gas atmosphere)  
Convertible to ON-Delay or OFF-Delay  
184  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Type  
700-RTC  
Timing Range  
Reset Time  
0.015…64 minutes; 0.05...120 seconds  
25 ms  
Repeat Accuracy  
Mounting  
1% (or 50 ms) at constant voltage and temperature  
Panel or strip mount  
Surge Suppression  
Haz. Loc. Ratings  
Not required. Timers have internal suppression  
Class I, Division 2, Groups A, B, C, and D  
24V AC/DC  
10 mA  
2.4 mA  
Maximum Allowable Leakage Current  
110/120V AC,  
120V DC  
Ambient Temperature (1)  
Operating:  
–20…+60 °C  
(–4…+140 °F)  
–20…+60 °C  
(–4…+140 °F)  
Storage:  
Standards Compliance  
Certifications  
ISA 12.12, CSA C22.2, No. 213  
cULus Listed (File No. E10314, Guide NOIV/NOIV7)  
(1) Continuous duty units placed close to each other (3 in a row) have a temperature range of –20…+45 °C (–4…+113 °F) or should have air circulated around the units.  
Approximate space of 3/4 in (mm) on all sides is needed.  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
185  
Relay and Timer Specifications  
Typical Wiring Diagram - 700-RTC Relays  
L1  
L2  
External  
Initiating Contact  
(N.O. or N.C.)  
Timed Contacts  
Any Combination  
of N.O. and N.C.  
P TIMED  
INST  
Instantaneous  
Contacts Any  
Combination of  
N.O. and N.C.  
L1 +  
L2  
Dimensions - 700-RTC Relays  
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.  
5.2 (2-13/64) Dia. Mounting Holes  
Approximate Shipping Weight 0.92 kg (2.1 lb.)  
NEMA Type 1 Enclosure for RTC Relays  
Approximate Shipping Weight 1.26 kg (2.8 lb.)  
186  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
IEC Control Relays  
Product Overview  
Bulletin No.  
Type  
700-CF and 700S-CF  
700-K  
Control Relay  
Miniature Control Relay  
Mechanically linked contacts  
Timer and latch operations  
Switch up to 690V AC and DC  
700S-CF for safety circuits  
Smallest size  
Long life  
Features  
Low power consumption  
Switch up to 690V AC and DC  
Contact Form  
Contact Type  
Contact Material  
Electrical  
4…12 poles, double break  
Cross stamp or bifurcated  
Silver, gold  
4...8 Poles Double Break  
Bifurcated  
Silver  
20 A (relay)  
Max. Current AC Resistive  
Min. load  
10 A  
10 A (adder deck)  
17V, 10 mA (Silver)  
5V, 3 mA (Gold)  
15V, 2 mA (700-K)  
12…600V AC  
9…250V DC  
12…600V AC  
9…250V DC  
Coil Voltage  
85…110% AC coils,  
80…110% DC coils  
85…110% AC Coils,  
80…110% DC Coils  
Coil Voltage Pickup  
Dielectric Withstand  
Reference  
2.5 kV  
2640V  
Electric Service Life (cycles)  
Certifications  
Sockets  
1.2 million at 10 A  
CE, cULus, CCC  
DIN Rail or panel mount  
188  
800K at 10 A 120V AC  
CE, cULus, CCC  
DIN Rail or panel mount  
213  
Page  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
187  
Relay and Timer Specifications  
700-CF Control Relay  
IEC industrial relays  
Mechanically linked contact performance per IEC 60947-5-1  
Gold plated, bifurcated version for low level switching applications  
Master control relay version rated 15 A (AC-15)  
Solid-state and pneumatic timing modules  
4-…10 Poles  
4-Pole AC Coil Voltage (Ratings for 700-CF Only)  
AC-12  
Ith [A]  
40 °C  
AC-15  
Contacts  
Gold Plated  
Bifurcated  
Contacts(2)  
Standard  
Master  
Contacts(1)  
Contacts(2)  
Connection  
Diagrams  
Ie [A]  
60 °C  
24/48V 120V 240V 400V 500V 600V 690V  
N.O. N.C.  
Cat. No.  
Cat. No.  
Cat. No.  
2
2
700-CF220700-CFB220700-CFM220⊗  
700-CF310700-CFB310700-CFM310⊗  
700-CF400700-CFB400700-CFM400⊗  
3
4
1
0
20  
20  
10  
10  
10  
6
2.5  
1
1
0
4
700-CF040700-CFB040⊗  
(1) For spring clamp terminals, insert R after 700-C. Example: Cat. No. 700-CRF220D.  
(2) All Cat. Nos. are factory-stocked.  
AC Coil Voltage Code  
The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 700-CF220becomes  
Cat. No. 700-CF220D for 120V, 60 Hz.  
100...  
110  
200...  
220  
208...  
240  
220...  
230  
230...  
240  
[V]  
12  
24  
32  
36  
42  
48  
100  
110  
120  
127  
200  
208  
230  
240  
50 Hz  
60 Hz  
R
Q
K
J
V
W
V
X
Y
X
KP  
KP  
D
P
S
KG  
L
H
L
F
VA  
T
D
KG  
A
50/60  
Hz  
KJ  
KY  
KP  
KD  
KG  
KL  
KL  
KF  
KA  
380...  
400  
400...  
415  
[V]  
277  
347  
380  
400  
440  
480  
500  
550  
600  
50 Hz  
T
I
E
N
KN  
G
B
B
M
C
C
60 Hz  
N
50/60 Hz  
KB  
188  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
4-Pole DC Coil Voltage (Ratings for 700-CF Only)  
AC-12  
AC-15  
Contacts  
Gold Plated  
Master  
Standard  
Bifurcated  
Contacts(2)  
Contacts(2)  
Contacts(1)  
Connection  
Diagrams  
Ith[A]  
Ie [A]  
40 °C 60 °C 24/48V 120V 240V 400V 500V 600V 690V  
N.O. N.C. Cat. No.  
Cat. No.  
Cat. No.  
2
2
700-CF220  
700-CFB220700-CFM220⊗  
3
4
1
0
20  
20  
10  
10  
10  
6
2.5  
1
1
700-CF310700-CFB310700-CFM310⊗  
700-CF400700-CFB400700-CFM400⊗  
(1) For spring clamp terminals, insert R after 700-C. Example: Cat. No. 700-CRF220D.  
(2) All Cat. Nos. are factory-stocked.  
DC Coil Voltage Code  
The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. example: Cat. No. 700-CF220becomes  
Cat. No. 700-CF220EJ for 24V DC, electronic with diode.  
48...  
72  
110...  
125  
220...  
250  
[V]  
9
12  
24  
36  
48  
60  
64  
72  
80  
110  
115 125 220  
230 250  
Electronic with  
diode  
EQ  
EJ  
EW  
EY  
ED  
EA  
Electronic with  
diode/ Quick  
Pick-up  
QJ  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
189  
Relay and Timer Specifications  
6- and 8-pole Relays  
Control Relays with Overlapping Side-Mounted Contacts  
AC-12  
AC-15  
Overlapping  
Side-  
Mounted  
Contacts  
Contacts  
Ith [A]  
Ie [A]  
Left Relay  
Aux. Arrangement Aux.  
Right  
Cat. No.  
40 60 24/  
°C °C 48V  
120 240 400 500 600 690  
N.O. N.C. N.O. N.C.  
V
V
V
V
V
V
4
3
2
4
3
2
0
1
2
0
1
2
1
1
1
2
2
2
1
1
1
2
2
2
700-CFZ1510⊗  
700-CFZ1420⊗  
700-CFZ1330⊗  
700-CFZ2620⊗  
700-CFZ2530⊗  
700-CFZ2440⊗  
Main  
Relay  
20 20 10  
10  
10  
6
2.5  
1
1
Side  
Contacts  
10 10  
6
6
5
3
1.6  
1
1
190  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Control Relays with Standard Side-mounted Contacts  
AC-12  
AC-15  
Standard  
Side-  
Contacts  
Mounted  
Ith [A]  
Ie [A]  
Left  
Aux.  
Relay  
Arrangement  
Right  
Aux.  
Cat. No. (1)  
Contacts  
40 60 24/  
°C °C 48V  
120V 240V 400V 500V 600V 690V  
N.O. N.C. N.O. N.C.  
700-  
4
3
2
4
3
2
0
1
2
0
1
2
1
1
1
2
2
2
1
1
1
2
2
2
CFZ0510⊗  
Main  
Relay  
700-  
CFZ0420⊗  
20 20 10  
10  
10  
6
2.5  
1
1
700-  
CFZ0330⊗  
700-  
CFZ0620⊗  
Side  
Contacts  
700-  
CFZ0530⊗  
10 10  
6
6
5
3
1.6  
1
1
700-  
CFZ0440⊗  
(1) All Cat. Nos. are factory stocked.  
AC Coil Voltage Code  
The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 700-CFZ051  
becomes Cat. No. 700-CFZ0510F.  
100...  
110  
200...  
220  
208...  
240  
220...  
230  
230...  
240  
[V]  
12  
24  
32  
36  
42  
48  
100  
110  
120  
127  
200  
208  
230  
240  
50 Hz  
60 Hz  
R
Q
K
J
V
W
V
X
Y
X
KP  
KP  
D
P
S
KG  
L
H
L
F
VA  
T
D
KG  
A
50/60  
Hz  
KJ  
KY  
KP  
KD  
KG  
KL  
KL  
KF  
KA  
380...  
400  
400...  
415  
[V]  
277  
347  
380  
400  
440  
480  
500  
550  
600  
50 Hz  
T
I
E
N
KN  
G
B
B
M
C
C
60 Hz  
N
50/60 Hz  
KB  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
191  
Relay and Timer Specifications  
Assignment of Contacts  
Device Combinations in Accordance with IEC 60947-1 / -4-1  
Auxiliary Contact Blocks  
Control Relays 700-CF (AC and DC Control)  
Circuit Diagram  
Control  
700-CF220  
700-CF310  
700-CF400  
(1)  
FrontMounting  
51 61  
100-FA02  
AC/DC  
AC/DC  
AC/DC  
AC/DC  
AC/DC  
AC/DC  
AC/DC  
22E + 02E = 24Y  
22E + 11E = 33Y  
22E + 20E = 42Y  
22E + 22E = 44Y  
22E + 31E = 53Y  
22E + 40E = 62Y  
22E + L22E = L44Y  
31E + 02E = 33Y  
31E + 11E = 42Y  
31E + 20E = 51Y  
31E + 22E = 53Y  
31E + 31E = 62Y  
31E + 40E = 71Y  
31E + L22E = L53Y  
40E + 02E = 42Y  
40E + 11E = 51Y  
40E + 20E = 60Y  
40E + 22E = 62Y  
40E + 31E = 71Y  
40E + 40E = 80Y  
40E + L22E = L62Y  
52 62  
53 61  
100-FA11  
100-FA20  
100-FA22  
100-FA31  
100-FA40  
100-FAL22  
54 62  
53 63  
54 64  
53 61 71 83  
54 62 72 84  
53  
73 83  
61  
54 62 74 84  
63 73 83  
53  
54 64 74 84  
53 61 75 87  
54 62 76 88  
(1) Control relay and auxiliary contact block AC/DC max. 4 N. C.  
192  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Auxiliary Contacts  
Standard  
Contacts  
Bifurcated  
Contacts  
(1)  
For Use  
With  
Photo  
Description  
N.O.  
N.C.  
Connection Diagrams  
Cat. No.  
Cat. No.  
0
1
2
1L  
0
1
2
3
4
2
1
0
1L  
4
3
2
1
0
100-FA02  
100-FA11  
100-FA20  
100-FAL11  
100-FA04  
100-FA13  
100-FA22  
100-FA31  
100-FA40  
100-FAB02  
100-FAB11  
100-FAB20  
Auxiliary Contact Blocks for Front  
Mounting§  
2- and 4-pole  
Quick and easy mounting without tools  
Electronic-compatible contacts down to  
17V, 5 mA  
100-FAB04  
100-FAB13  
100-FAB22  
100-FAB31  
100-FAB40  
Mechanically linked performance  
between N.O. and N.C. poles and to the  
main relay poles (except for L types)  
Models with equal function with several  
terminal numbering choices  
1L = Late break N.C./early make N.O.  
Bifurcated version for switching down to  
5V, 3 mA  
700-CF  
1+1L  
1+1L  
100-FAL22  
(1) For spring clamp terminals, insert CR after 100-. Example: Cat. No. 100-CRFA02.  
Description  
N.O.  
N.C.  
Connection Diagrams  
For Use With Cat. No.  
Photo  
0
1
0
1
2
1
0
2
1
0
100-SA01  
100-SA10  
100-SA02  
100-SA11  
100-SA20  
Auxiliary Contact Blocks for Side Mounting without  
Sequence Terminal Designations§  
1- and 2-pole  
Two-way numbering for right or left mounting on the contactor  
Quick and easy mounting without tools  
700-CF  
Electronic-compatible contacts down to 17V, 10 mA  
Mirror contact performance to the main relay poles  
1L = Late break N.C./early make N.O.  
1L  
1L  
100-SAL11  
IMPORTANT For maximum number of contacts, see the following tables.  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
193  
Relay and Timer Specifications  
(1)  
700-CF (AC electronic coils), vertical mounting, 60 °C  
Max. N.O.  
Front + Side  
Aux.  
Max. N.C.  
Front + Side  
Aux.  
Max. N.O. + N.C.  
Front +  
Side Aux.  
Cat. No.  
700…  
Max. N.O.  
Side Aux.  
Max. N.C.  
Side Aux.  
Max. N.O.  
Front Aux.  
Max. N.C.  
Front Aux.  
CF400  
CF310  
CF220  
CF040  
2
2
4
2
4
4
4
4
4
4
6
6
8
6
7
5
5
2
8
8
8
6
(2)  
4
4(3)  
2
(2)  
4
2
0
(1) For other operating conditions, please contact your local Rockwell Automation sales office or Allen-Bradley distributor.  
(2) With no front auxiliary contacts installed. Otherwise 3 N.C. Maximum  
(3) With no side auxiliary contacts installed. Otherwise 3 N.C. Maximum  
(1)  
700-CF (DC conventional coils), vertical mounting, 60 °C  
Max. N.O.  
Front + Side  
Aux.  
Max. N.C.  
Front + Side  
Aux.  
Max. N.O. + N.C.  
Front +  
Side Aux.  
Cat. No.  
700…  
Max. N.O.  
Side Aux.  
Max. N.C.  
Side Aux.  
Max. N.O.  
Front Aux.  
Max. N.C.  
Front Aux.  
CF400  
CF310  
CF220  
2
2
2
2
2
2
4
4
4
4 (2)  
4 (2)  
2
6
6
6
5
5
4
8
8
8
(1) For other operating conditions, please contact your local Rockwell Automation sales office or Allen-Bradley distributor.  
(2) With no side auxiliary contacts installed. Otherwise 3 N.C. Maximum  
194  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Control Modules  
Connection  
Diagrams  
Reset  
Time  
Repeat  
Accuracy  
Photo  
Description  
Delay  
For Use With  
Cat. No.  
Pneumatic Timing  
0.3…30 s  
100-FPTA30  
Modules(1) ON-Delay  
Pneumatic timing element  
contacts switch after the delay  
time. The contacts on the main  
control relay continue to  
operate without delay.  
25…90  
ms for AC  
Coils  
1.8…180 s  
0.3…30 s  
1.8…180 s  
100-FPTA180  
100-FPTB30  
100-FPTB180  
(1)  
+/-10%  
700-CF all  
Pneumatic Timing Modules  
OFF-Delay  
Pneumatic timing element  
contacts switch after the delay  
time. The contacts on the main  
control relay continue to  
operate without delay.  
47…85  
ms  
for DC coils  
0.1…3 s  
1…30 s  
10…180 s  
0.1…3 s  
1…30 s  
100-ETA3  
700-CF  
110…240V AC  
110…250V DC  
100-ETA30  
Electronic Timing Modules  
— On-Delay  
conventional coils  
100-ETA180  
100-ETAZJ3  
100-ETAZJ30  
Delay of the control relay coil  
assembly.  
100 ms  
+/-1%  
The control relay is energized  
at the end of the delay time.  
700-CF  
24…48V DC  
coils  
10…180 s  
100-ETAZJ180  
0.3…3 s  
1…30 s  
10…180 s  
0.3…3 s  
1…30 s  
100-ETB3  
700-CF  
110…240V AC  
coils  
100-ETB30  
100-ETB180  
100-ETBKJ3  
100-ETBKJ30  
Electronic Timing Modules  
— Off-Delay  
Delay of the control relay coil  
assembly.  
100 ms  
+/-1%  
After interruption of the  
control signal, the control relay  
is deenergized at the end of  
the delay time.  
700-CF  
24V AC  
coils  
10…180 s  
100-ETBKJ180  
(1) On-Delay modules cannot be used with side-mounted auxiliary contacts on DC coil relays.  
Connection  
Diagrams  
Photo  
Description  
For Use With  
Cat. No.  
Mechanical Latch  
Following relay latching, the relay coil is immediately de-energized (off) by the  
N.C. auxiliary contact (65-66).  
700-CF with AC  
coils  
100-FL11⊗  
Electrical or manual release  
1 N.O. + 1 N.C. auxiliary contacts  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
195  
Relay and Timer Specifications  
Connection  
Diagrams  
Photo  
Description  
For Use With  
Cat. No. (1)  
100-FSC48  
100-FSC280  
100-FSC480  
100-FSV55  
100-FSV136  
24…48V  
50/60 Hz  
RC Module  
AC Operating  
Mechanism  
110…280V  
50/60 Hz  
700-CF with AC coils  
380…480V  
50/60 Hz  
12…55V AC/  
12…77V DC  
Surge Suppressors  
For limitation of coil switching  
transients.  
56…136V AC/  
78…180V DC  
Varistor Module  
AC/DC Operating  
Mechanism  
700-CF all  
Plug-in, coil mounted  
137…277V AC/  
181…350V DC  
100-FSV277  
100-FSV575  
278…575V AC  
Diode Module  
DC Operating  
Mechanism  
Dropout Time  
70…95 ms  
700-CF with Conventional DC  
coils  
12…250V DC  
100-FSD250  
(1) For spring clamp terminals, insert CR after 100-. Example: Cat. No. 100-CRFSC48.  
Coil Voltage Code  
The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 100-FL11becomes  
Cat. No. 100-FL11J.  
[V] (1)  
50 Hz  
60 Hz  
24  
K
48  
Y
100  
KP  
110  
D
120  
D
230...240 240  
277  
T
380...400 400...415 440  
480  
B
VA  
T
N
G
B
J
A
N
(1) For special voltages, consult your local Rockwell Automation sales office or Allen-Bradley distributor.  
Connection  
Diagrams  
For Use With  
(Relays)  
Photo  
Description (Relays)  
Cat. No.  
Input:  
24V DC  
Output:  
110…240V AC  
100-JE  
DC Interface (electronic)  
Interface between the DC control signal (PLC) and the AC  
Input:  
operating mechanism of the control relay.  
12V DC  
700-CF with  
110…240V AC  
coils  
Control (input) voltage  
100-JE12  
100-JE48  
Output:  
110…240V AC  
12V DC  
24V DC  
48V DC  
Input:  
Requires no additional surge suppression on the relay coils  
48V DC  
Output:  
110…240V AC  
196  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Specifications 100-J... DC Interfaces  
Cat. No. 100-JE  
Cat. No. 100-JE12  
Cat. No. 100-JE48  
Electrical  
Input Voltage  
24V DC  
12V DC  
48V DC  
Input Voltage Range  
Output Voltage  
Power Consumption  
Minimum Actuation  
Mechanical  
18…30V DC  
110…240V AC  
0.1…0.4 W  
6…12V DC  
35…48V DC  
110…240V AC  
0.2…0.5 W  
110…240V AC  
0.02…0.12 W  
5V DC, 2 mA DC  
5V DC, 2 mA DC  
5V DC, 2 mA DC  
Finger Protection  
IP20  
IP20  
IP20  
0…10 ms + pickup time  
of the contactor  
0…10 ms + pickup time  
of the contactor  
0…10 ms + pickup time  
of the contactor  
Pickup Time  
0…10 ms + dropout time  
of the contactor  
0…10 ms + dropout time  
of the contactor  
0…10 ms + dropout time  
of the contactor  
Dropout Time  
Max. Cycles Per Second  
Isolation/Breakdown Voltage  
Rated Impulse Withstand Voltage  
Environmental  
2 (1)  
In: 50V, Out: 250V  
4 kV  
2 (1)  
In: 50V, Out: 250V  
4 kV  
2 (1)  
In: 50V, Out: 250V  
4 kV  
Ambient Temperature Range  
Storage Temperature Range  
Operating Life  
-25…+60 °C  
-50…+80 °C  
-25…+60 °C  
-50…+80 °C  
-25…+60 °C  
-50…+80 °C  
100 + million ops  
100 + million ops  
100 + million ops  
Construction  
2
2
2
1 Wire  
2 Wire  
1 Wire  
2 Wire  
0.5…2.5 mm  
0.5…2.5 mm  
0.5…2.5 mm  
Flexible wire  
2
2
2
0.75…2.5 mm  
0.75…2.5 mm  
0.75…2.5 mm  
2
2
2
Wire Size Range  
Solid wire  
1.0…2.5 mm  
1.0…2.5 mm  
1.0…2.5 mm  
2
2
2
1.0…2.5 mm  
1.0…2.5 mm  
1.0…2.5 mm  
Solid and Stranded  
Tightening Torque  
18…14 AWG  
1…1.5 N•m / 7…15 lb•in  
LED  
18…14 AWG  
1…1.5 N•m / 7…15 lb•in  
LED  
18…14 AWG  
1…1.5 N•m / 7…15 lb•in  
LED  
Type of Light  
(1) To consider the maximum operations/hour of the relays.  
Assembly Components  
Photo  
Description  
For Use With  
Pkg Qty. (1)  
Cat. No.  
Protective Covers  
Provides protection against unintended manual operation  
700-CF all  
1
100-SCCA  
Protective Covers  
100-FA, -FB, -FC, -FP, -FL; 10  
100-SCFA  
Provides protection against unintended manual operation  
For contactors and front-mounted auxiliary contacts, pneumatic timers,  
and latches  
(1) All Cat. Nos. are factory stocked.  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
197  
Relay and Timer Specifications  
Accessories  
Uniform labeling materials for contactors, motor startup equipment, relays, and circuit breakers.  
Pkg.  
Photo  
Description  
Cat. No.  
Qty. (1)  
10  
100-FMS  
Label Sheet  
105 self-adhesive paper labels each, 6 x 17 mm  
10  
100-FMP  
100-FMC  
Marking Tag Sheet 160 perforated paper labels each, 6 x 17 mm, to be used with a transparent cover  
Transparent Cover To be used with marking tag sheets  
100  
100-FMA1 (2)  
100-FMA2  
100  
Marking Tag Adapters To be used with marking tag: System V4/V5  
System 1492 W  
(1) Must be ordered in multiples of package quantities.  
(2) Marker for 100-FMA1 must be purchased from a third party.  
198  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Coils  
Photo  
AC Coil  
Code  
AC Voltages  
60Hz  
12V  
Cat. No.  
700-CF  
DC Coil Code DC Voltages  
Cat. No.  
700-CF  
50Hz  
50/60Hz  
Q
R
TA006  
EQ  
EJ  
12V  
24 V  
TC708E  
TC714E  
TC714Q  
TC724E  
TC719E  
12V  
TA404  
TA013  
TA407  
TA855  
TA481  
TA410  
TA482  
TA414  
TA860  
TA861  
TA473  
TA856  
TA425  
TA428  
TA862  
TA049  
TA296  
J
24V  
QJ  
24V  
K
24V  
E Y  
EW  
ED  
EA  
48…72V  
36…48  
KJ  
V
24V  
32V  
36V  
110…125 TC733E  
220…250 TC747E  
W
X
36V  
42V  
48V  
Y
48V  
KY  
KP  
D
48V  
100V  
100V  
110V  
100 - 110V  
120V  
KD  
P
110V  
120V  
127V  
200V  
S
KG  
H
200 - 220V  
208V  
208 - 240V  
200V  
L
200 - 220V  
KL  
A
200 - 230V TA864  
220V  
220 - 230V  
240V  
260V  
TA474  
TA441  
TA851  
TA440  
TA480  
TA858  
TA065  
TA067  
TA071  
TA863  
TA457  
TA475  
TA859  
TA479  
TA476  
F
KF  
VA  
T
230V  
230 - 240V  
240V  
277V  
KA  
I
240V  
347V  
380V  
440V  
E
N
380 - 400V  
KN  
G
400V  
400-415V  
440V  
B
480V  
KB  
M
C
440V  
500V  
550V  
600V  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
199  
Relay and Timer Specifications  
Specifications - 700-CF..., 700S-CF Relays  
Main Relay  
Cat. Nos.  
700-CF,  
FrontMounted  
Standard  
Main Relay  
Cat. No.  
700-CFB,  
700S- CFB  
Master Relay FrontMounted Side-mounted  
Cat. No.  
Bifurcated  
Auxiliary  
Contacts  
Auxiliary  
Contacts  
Auxiliary  
700-CFM  
700S- CF  
Contacts  
Contact Ratings — NEMA  
A600, P600  
17V, 10 mA  
10 A  
A600, Q600  
17V, 5 mA  
6 A  
A600, Q600  
8V, 5 mA  
3 A  
2 x A600, P600  
A600, Q600  
5V, 3 mA  
3 A  
A600, Q600  
17V, 10 mA  
6 A  
Min. Contact Rating  
15 A  
15 A  
15 A  
15 A  
7.5 A  
5 A  
24V  
48V  
10 A  
6 A  
3 A  
3 A  
6 A  
120V  
10 A  
6 A  
3 A  
3 A  
6 A  
Contact Ratings — IEC AC-15  
(solenoids, contactors) at rated  
voltage  
240V  
10 A  
5 A  
3 A  
3 A  
5 A  
400V  
6 A  
3 A  
2 A  
2 A  
3 A  
IEC 60947-5-1  
480V/500V  
2.5 A  
1 A  
1.6 A  
1 A  
1.2 A  
0.7 A  
0.7 A  
1.2 A  
0.7 A  
0.7 A  
1.6 A  
1 A  
600V  
690V  
2 A  
1 A  
1 A  
2 A  
1 A  
I
20 A  
th  
230V  
400V  
690V  
8 kW  
14 kW  
24 kW  
20 A  
40 °C  
60 °C  
10 A  
6 A  
10 A  
6 A  
20 A  
20 A  
10 A  
6 A  
10 A  
6 A  
AC-12 (Control of  
resistive loads)  
IEC 60947-5-1  
I
th  
230V  
400V  
690V  
24V  
8 kW  
14 kW  
24 kW  
15 A  
10 A  
9 A  
6 A  
3.2 A  
1 A  
20 A  
20 A  
8 A  
6 A  
3.2 A  
1 A  
6 A  
3.2 A  
1 A  
48V  
10 A  
DC-12 Switching DC Loads L/R <  
1ms, Resistive Loads  
110V  
220V  
440V  
24V  
6 A  
3.5 A  
0.7 A  
0.2 A  
5 A  
IEC 60947-5-1  
1 A  
0.5 A  
0.2 A  
2.5 A  
1.5 A  
0.6 A  
0.3 A  
0.15 A  
1.5 A  
0.4 A  
5 A  
0.5 A  
0.2 A  
2.5 A  
1.5 A  
0.6 A  
0.3 A  
0.15 A  
0.5 A  
0.2 A  
5 A  
0.4 A  
5 A  
48V  
3 A  
3 A  
3 A  
2.5 A  
0.68 A  
0.32 A  
0.15 A  
DC-13 IEC 60947-5-1,  
Solenoids and contactors  
110V  
220V  
440V  
1.2 A  
0.6 A  
0.3 A  
1.2 A  
0.6 A  
0.15 A  
1.2 A  
0.6 A  
0.3 A  
State of N.C. Contacts if N.O. contact welds  
Location of welded  
N.O. contacts  
Main  
Open  
Open  
Front aux.  
Open  
Side aux.  
Open (2)  
Main  
Mechanically Linked Contacts (1)  
Front aux.  
Open  
(1) Side mounted auxiliary contacts provide “mirror contact”performance with main poles only.  
(2) Defined in IEC 60947-5-1 annex L. Mechanically linked is a relationship between contacts of opposite types (i.e., N.O. and N.C.).  
200  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Attribute  
Aux./Pneumatic  
Timer Contact  
(Front mounted)  
Cat. No.  
700-CF  
Mechanical Life  
Electrical Life  
[Mil]  
[Mil]  
[g]  
15  
1.5  
390  
5
AC-15  
1.5  
(240V, 3 A)  
Weight  
AC Coil  
Terminal Cross-Sections  
Terminal Type  
Terminal Size per IEC60 947-1  
2 x A4  
1.5…6  
2 x A4  
0.5…2.5  
0.75…2.5  
18…14  
2
[mm ]  
Solid/Stranded  
1 Conductor  
2 Conductor  
(1)  
2
[mm ]  
1.5…6  
Max. Wire Size per UL/CSA  
Tightening Torque  
[AWG]  
[lb·in]  
[N·m]  
16…10  
13.3…17.7  
1.5…2.0  
8.9…13.3  
1…1.5  
Tightening Torque  
(1) For 16 or more strands, end ferrule is required.  
DC Switching Ratings for 700-CF Main Poles in Series (Resistive Load at 60 °C)  
Attribute  
24/48V  
125V  
1 pole  
2 poles  
3 poles  
15/10 A  
6 A  
25 A  
25 A  
6 A  
25 A  
25 A  
25 A  
3 A  
220V  
1 A  
440V  
0.4 A  
1 A  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
201  
Relay and Timer Specifications  
Control Circuit  
Attribute  
Cat. No. 700-CF  
Operating Voltage  
Pickup  
Dropout  
Pickup  
[x U ]  
0.85…1.1  
0.3…0.6  
0.8…1.1  
0.1…0.6  
0.7...1.25  
0.3...0.4  
s
AC 50/60 Hz  
[x U ]  
s
[x U ]  
s
DC (conventional) (1)  
DC (electronic EQ, EW)  
DC (electronic EY)  
Dropout  
Pickup  
[x U ]  
s
[x U ]  
s
Dropout  
Pickup  
[x U ]  
s
[x U ]  
0.8...1.25  
0.3...0.4  
0.7...1.12 (2)  
s
Dropout  
Pickup  
[x U ]  
s
[x U ]  
s
DC (electronic ED)  
Dropout  
Pickup  
[x U ]  
s
0.3...0.4  
[x U ]  
0.8...1.1  
s
DC (electronic EA)  
Coil Consumption  
AC 50/60 Hz  
Dropout  
[x U ]  
0.3...0.4  
s
Inrush  
Sealed  
Inrush  
Sealed  
[VA]  
[VA/W]  
[W]  
75  
9.5/2.7  
7.7  
DC (conventional)  
DC (electronic EQ, EJ)  
DC (electronic EY)  
DC (electronic ED)  
[W]  
6.3  
Inrush (avg./ peak)  
Sealed  
[W]  
10/17  
1.7  
[W]  
Inrush (avg./ peak)  
Sealed  
[W]  
10/17  
1.9  
[W]  
Inrush (avg./ peak)  
Sealed  
[W]  
12/19  
2.1  
[W]  
Inrush (avg./ peak)  
Sealed  
[W]  
14/22  
3.0  
DC (electronic EA)  
Operating Times  
AC 50/60 Hz  
[W]  
Pickup Time  
Dropout Time  
Pickup Time  
[ms]  
[ms]  
[ms]  
[ms]  
[ms]  
[ms]  
[ms]  
[ms]  
[ms]  
[ms]  
[ms]  
[ms]  
15…30  
10…60  
40…70  
7…15  
14...20  
70...125  
25…50  
27...45  
25...50  
23...33  
20...50  
15…22  
DC (conventional)  
Dropout Time  
Opening Delay  
Opening Delay  
Closing Delay  
Opening Delay  
Closing Delay  
Opening Delay  
Closing Delay  
Opening Delay  
With integrated diode  
With external diode  
DC (electronic- EQ, EJ)  
DC (electronic - EW EY, ED, EA)  
DC (electronic- QJ)  
202  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Attribute  
Cat. No. 700-CF  
Min OFF time  
[ms]  
50  
Max. ripple  
15%  
Latch Attachment Release, 100-FL  
AC  
DC  
[VA/W]  
[W]  
45/40  
25  
Coil Consumption  
Contact Signal Duration  
[min./max]  
0.03…15 s  
Timing Attachment  
at min. time setting  
at max. time setting  
[ms]  
[ms]  
10  
Reset Time, 100- ETA, 100-ETB  
70  
Repeat Accuracy  
10%  
(1) For 9V DC, code ZR, use operating voltage 0.65…1.3 x U .  
s
For 24V DC, code ZJ, DJ, or EJ use operating voltage 0.7…1.25 x U .  
s
(2) At 110V DC, coil code ED has an operating voltage range of 0.7...1.25 x U .  
s
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
203  
Relay and Timer Specifications  
General Specifications - 700-CF Relays  
Cat. No. 700-CF  
Rated Insulation Voltage U  
i
IEC  
690V  
600V  
6 kV  
UL; CSA  
Rated Impulse Strength U  
imp  
High Test Voltage 1 minute (per IEC 60947-  
2500V  
Rated Voltage U  
e
AC  
DC  
115, 230, 400, 500, 690V  
24, 48, 110, 220, 440V  
Short-Circuit Protection gG Fuse 20 A  
Rated Frequency  
50/60 Hz, DC  
Ambient Temperature  
Storage  
–55…+80 °C (–67…+176 °F)  
–25…+60 °C (–13…+140 °F)  
Operation at nominal current  
15% current reduction for AC-12 at > 60 °C  
Corrosion Resistance  
Altitude  
–25…+70 °C (–13…+158 °F)  
humid-alternating climate, cyclic, per IEC 60068-2-30 and DIN 50 016, 56 cycles  
2000 m above mean sea level, per IEC 60 947-4  
Type of Protection  
IP2X (IEC 60529 and DIN 40050)  
Shock Resistance  
in connected state  
IEC 60068-2: Half sinusoidal shock 11 ms, 30 G (in 3 directions)  
Vibration Resistance  
Standards Compliance  
IEC 60068-2: Static >2 G, in normal position no malfunction <5 G  
UL 508, CSA C22.2 No. 14, EN/IEC 60947-1, -5-1, Meets the material restrictions for European Directive 2002/95/EC - EU-  
cULus Listed (File No. E14840, Guide NKCR/NKCR7), CE Marked, CCC Certified  
Certifications  
Utilization Category Table from EN 60947-5-1  
Verification of Making and Breaking Capacities of Switching Elements Under Normal Conditions Corresponding to the Utilization Categories (1)  
Normal Condition of Use  
Number and Rate of Making and Breaking  
operations  
Make (3)  
Break (3)  
Utilization  
Category  
No.  
Operating  
cycles per  
minute  
ON time [s]  
I/I  
U/U  
cos φ  
I/I  
U/U  
e
cos φ  
operating  
(6)  
e
e
e
cycles (5)  
AC-12 (2)  
AC-13 (2)  
AC-14 (2)  
AC-15 (2)  
DC  
1
2
1
1
0.9  
1
1
1
1
0.9  
6050  
6050  
6050  
6050  
6
6
0.05  
0.05  
0.65  
0.3  
0.65  
0.3  
6
1
1
1
6
0.05  
10  
1
1
0.3  
1
1
0.3  
6
0.05  
1
T
1
1
T
6
0.95  
0.95  
DC-12  
1 ms  
6 x P (4)  
1 ms  
6 x P (4)  
15 ms  
6050  
6050  
6050  
0.05 (6)  
0.05 (6)  
0.05 (6)  
DC-13  
DC-14 (2)  
1
1
1
1
6
10  
1
15 ms  
1
1
(1) See sub-clause 8.3.3.5.2.  
(2) Where the break current differs from the make current value, the ON time refers to the make current value after which the current is reduced to the break current value for a suitable period e.g., 0.05 s.  
(3) For tolerances on test quantities, see sub-clause 8.3.2.2.  
(4) The value ”6 x Presults from an empirical relationship which is found to represent most DC magnetic loads to an upper limit of P = 50 W, e.g., 6 x P = 300 W.  
(5) The first 50 operating cycles shall be run at U/U = 1.1 with the loads set at U .  
e
e
(6) The ON time shall be at least equal to T  
.
0.95  
I
U
Rated operational current, I Current to be made or broken  
Rated operational voltage, U Voltage before make  
e
e
PU I Steady-state power consumption (W)  
e
e
T
Time to reach 95% of the steady-state current (ms)  
0.95  
204  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Contact Rating Table from EN 60947-5-1  
Examples of Contact Rating Designation Based on Utilization Categories  
Conventional  
NEMA  
IEC  
Utilization  
Category  
Thermal  
Current Ithe  
(A)  
Designation  
Rated Operational Current Ie (A) at Rated Operational Voltage Ue  
VA Rating  
(1)  
AC  
120V  
6
240V  
3
380V  
480V  
500V  
1.4  
600V  
1.2  
0.6  
0.3  
Make  
7200  
7200  
7200  
3600  
3600  
3600  
1800  
1800  
1800  
432  
Break  
720  
720  
720  
360  
360  
360  
180  
180  
180  
72  
A150  
A300  
A600  
B150  
B300  
B600  
C150  
C300  
C600  
D150  
D300  
E150  
AC-15  
AC-15  
AC-15  
AC-15  
AC-15  
AC-15  
AC-15  
AC-15  
AC-15  
AC-15  
AC-14  
AC-14  
DC  
10  
10  
10  
5
6
6
3
1.9  
1.5  
3
1.5  
0.72  
.035  
600V  
0.4  
5
3
5
3
1.5  
0.95  
0.75  
2.5  
2.5  
2.5  
1.0  
1.0  
0.5  
1.5  
1.5  
1.5  
0.6  
0.6  
0.3  
125V  
2.2  
2.2  
2.2  
1.1  
1.1  
1.1  
0.55  
0.55  
0.55  
0.22  
0.22  
0.75  
0.75  
0.3  
0.47  
0.375  
432  
72  
250V  
1.1  
216  
36  
440V  
500V  
Make  
275  
Break  
275  
275  
275  
138  
138  
138  
69  
N150  
N300  
N600  
P150  
P300  
P600  
Q150  
Q300  
Q600  
R150  
R300  
DC-13  
DC-13  
DC-13  
DC-13  
DC-13  
DC-13  
DC-13  
DC-13  
DC-13  
DC-13  
DC-13  
10  
10  
10  
5
275  
1.1  
0.63  
0.55  
275  
0.55  
0.55  
0.27  
0.27  
0.1  
0.2  
138  
5
138  
5
0.31  
0.27  
138  
2.5  
2.5  
2.5  
1.0  
1.0  
0.1  
69  
69  
69  
0.15  
0.13  
69  
69  
28  
28  
28  
28  
(1) This letter stands for the conventional thermal current and identifies AC or DC: for example, B=5 A AC. The number that follows is the rated insulation voltage.  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
205  
Relay and Timer Specifications  
Dimensions - 700-CF... Relays  
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.  
Mounting Position  
AC and DC Control Relay with DC Electronic Coil  
(1)  
Front View  
Side View  
(1) May be mounted to 35 mm EN 50 022 DIN Rail.  
DC Control Relay  
Side View  
Front View  
All AC Control Relays and DC Control Relays with 12V or 24V DC Electronic Coil  
Type  
a
b
c
c1  
c2  
c2  
c2  
Ød  
2 screws 4.5  
d1  
d1  
d1  
d2  
45  
81  
80.5  
75.5  
6
60  
35  
(1-25/64)  
700-CF, -CFB, -CFM  
(1-25/32)  
(3-3/16)  
(3-11/64)  
(3-3/32)  
(1/4)  
(3/16)  
(2-23/64)  
DC Control Relays with 48...72V, 110...125V or 220...250V DC Electronic Coil  
Type  
a
b
c
c1  
Ød  
d2  
d2  
45  
(1-25/32)  
105  
(4-1/8)  
80.5  
(3-11/64)  
75.5  
(3-3/32)  
6
(1/4)  
2 screws 4.5  
(3/16)  
60  
(2-23/64)  
35  
(1-25/64)  
700-CF, -CFB, -CFM  
DC Control Relays with Conventional Coil  
Type  
a
b
c
c1  
Ød  
45  
(1-25/32)  
81  
(3-3/16)  
106.5  
(4-3/16)  
101.5  
(4)  
6
(1/4)  
2 screws 4.5  
(3/16)  
60  
(2-23/64)  
35  
(1-25/64)  
700-CF, -CFB, -CFM  
206  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Accessories - 700-CF Relays  
Relay with  
AC Control Relay  
DC Control Relay  
mm (inches)  
mm  
(inches)  
(c/c1 + 1 – 37/64)  
(a + 23/64)  
(c/c1 + 2 – 23/64)  
(b + 15/16)  
(c/c1 + 2 – 31/64)  
(b + 23/64)  
(b + 1/8)  
Auxiliary Contact for Front Mounting  
Auxiliary Contact for Side Mounting  
Pneumatic Timing Module  
Solid-state Timing Module  
Mechanical Latching  
DC Interface  
2- or 4-pole  
1- or 2-pole  
c/c1 + 39  
a + 9  
c/c1 + 39  
a + 9  
c/c1 + 1 – 37/64)  
(a + 23/64)  
c/c1 + 58  
b + 24  
c/c1 + 61  
b + 9  
on coil terminal side  
b + 24  
(b + 15/16)  
on coil terminal side  
on coil terminal side  
label sheet  
Surge Suppressor  
Labelling with:  
b + 3  
b + 3  
+0  
(b + 1/8)  
(+0)  
+0  
(+0)  
marking tag with cover  
marking tag carrier for System V4/V5  
+0  
(+0)  
+0  
(+0)  
+5.5  
(+7/32)  
+5.5  
+5.5  
(+7/32)  
(+7/32)  
marking tag carrier for System Bull. 1492W  
+5.5  
(+7/32)  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
207  
Relay and Timer Specifications  
700S-CF Control Relays  
The 700S-CF Safety Control Relay provides mechanically or mirror contact performance, which are required  
in feedback circuits for safety applications. Bifurcated contacts are ideal for low energy feedback safety circuits  
where high contact reliability is required.  
IEC industrial safety relay  
Mechanically linked contacts as per IEC 60947-5-1  
Third party certification SUVA  
Red cover and mechanically linked contact symbol on front face  
Gold plated, bifurcated version for low level switching applications  
Permanently fixed front mounted auxiliary contact block  
Type CF and CFB Safety Control Relays — 8-Pole AC Coil Voltage (Ratings for 700S-CF Only)  
AC-12  
AC-15  
Contacts  
Standard  
Contacts  
(Main)  
Gold-Plated  
Bifurcated  
(Front)  
Connection Diagrams  
Gold-Plated  
Bifurcated,  
All Contacts  
Ith [A]  
Ie [A]  
(1)  
Cat. No.  
Main  
Contacts  
Auxiliary  
Contacts  
Cat. No.  
40 60 24/  
°C °C 48V  
120 240 400 500 600 690  
N.O. N.C.  
V
V
V
V
V
V
20 20 10  
10  
10  
6
2.5  
1
1
700S-  
CF440BC  
700S-  
CFB440C  
4
4
Main  
Contacts  
700S-  
700S-  
5
6
3
2
CF530BC  
CFB530C  
10  
6
6
6
5
3
1.6  
1
1
Adder  
Deck  
Contacts  
700S-  
CF620BC  
700S-  
CFB620C  
(1) Ratings for 700S-CFB are on Specifications  
AC Coil Voltage Code  
The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 700S-CF440BC  
becomes Cat. No. 700S-CF440DBC for 120V, 60 Hz.  
[V]  
12  
24  
32  
36  
42  
48  
100  
100... 110  
110  
120  
127  
200  
200... 208  
220  
208... 220...  
240  
L
230  
50 Hz  
60 Hz  
R
K
V
W
V
X
Y
KP  
KP  
KP  
D
P
S
KG  
KG  
L
H
F
Q
J
X
KD  
D
KG  
KL  
KL  
50/60  
Hz  
KJ  
KY  
[V]  
230  
230...  
240  
240  
277  
347  
380  
380...  
400  
400  
400...  
415  
440  
480  
500  
550  
600  
50 Hz  
60 Hz  
VA  
T
T
I
E
N
KN  
G
B
B
M
C
C
A
N
50/60 Hz KF  
KA  
KB  
208  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Type CF and CFB Safety Control Relays — 8-Pole DC Coil Voltage (Ratings for 700S-CF Only)  
AC-12  
AC-15  
Contacts  
Ith [A]  
Ie [A]  
Connection Diagrams  
Standard  
Contacts  
(Main)  
Gold-  
Gold  
Plated  
Bifurcated  
All  
Plated  
Bifurcated Contacts  
(Front)  
Cat. No.  
Cat. No.(1)  
Main  
Contacts  
Auxiliary  
Contacts  
No. of  
N.O.  
No. of  
N.C.  
40 60  
°C °C  
24/48V 120V 240V 400V 500V 600V 690V  
Contacts Contacts  
20 20 10  
10  
10  
6
2.5  
1
1
4
5
6
4
3
2
700S-  
700S-  
CF440BC CFB440C  
Main  
Contacts  
700S-  
700S-  
CF530BC CFB530C  
Adder  
Deck  
Contacts  
10  
6
6
6
5
3
1.6  
1
1
700S-  
700S-  
CF620BC CFB620C  
(1) Ratings for 700S-CFB are on Specifications  
DC Coil Voltage Code  
The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 700S-CFB440C  
becomes Cat. No. 700S-CFB440EJC for 24V DC, electronic with diode.  
48...  
72  
110...  
125  
220...  
250  
[V]  
9
12  
24  
36  
48  
60  
64  
72  
80  
110  
115 125 220  
230 250  
Electronic with  
diode  
EQ  
EJ  
EW  
EY  
ED  
EA  
Electronic with  
diode/ Quick  
Pick-up  
QJ  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
209  
Relay and Timer Specifications  
Assignment of Contacts  
Safety Control Relays with Front-mount Auxiliary Contacts, 8-Pole AC or DC Coil Voltage  
53 61 71 81  
61  
61  
73 83  
71 83  
53  
53  
54 62 72 82  
54 62 72 84  
21  
54 62 74 84  
21  
13  
A1  
A1  
A1  
21  
33 43  
33 43  
33 43  
13  
13  
K1  
K1  
K1  
A2 14 22 34 44  
A2 14 22 34 44  
A2 14 22 34 44  
700S-CF440…  
700S-CFB440…  
700S-CF530…  
700S-CFB530…  
700S-CF620…  
700S-CFB620…  
Specifications - 700S-CF Relays  
For more 700S-CF Specifications, see Specifications - 700-CF..., 700S-CF Relays on page 200.  
Cat. No.  
700S-CF  
Aux. Contact  
(Front-mounted)  
Mechanical Life  
Electrical Life  
[Mil]  
[Mil]  
[g]  
15  
1.5  
390  
15  
1.5  
AC-15 (240V, 3 A)  
AC Coil  
Weight  
Terminal Cross-Sections  
Terminal Type  
Terminal Size per IEC 947-1  
2 x A4  
1.5…6  
2 x A4  
0.5…2.5  
0.75…2.5  
18…14  
2
1 Conductor  
2 Conductor  
[mm ]  
Solid/ Stranded (1)  
[mm2]  
[AWG]  
[lb•in]  
[N•m]  
1.5…6  
Max. Wire Size per UL/CSA  
Tightening Torque  
16…10  
13.3…22  
1.5…2.5  
8.9…13.3  
1…1.5  
Tightening Torque  
UL 508, CSA C22.2 No. 14, EN/IEC 60947-1, -5-1, Meets the material restrictions for  
European Directive 2002/95/EC - EU-RoHS  
Standards Compliance  
Certifications  
cULus Listed (File No. E14840, Guide NKCR/NKCR7), CE Marked, CCC Certified  
(1) For 16 or more strands, end ferrule is required  
210  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Dimensions - 700S-CF Relays  
Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.  
c2  
c1  
c
AC and DC Safety Control Relays with 12V or 24V DC Electronic Coil  
Cat. No.  
a
b
c
c1  
c2  
Ød  
d1  
d2  
45  
81  
119.5  
114.5  
6
2 - 4.5  
60  
35  
700S-CF  
(1-25/32)  
(3-3/16)  
(4-3/4)  
(4-43/64)  
(1/4)  
(2 - 3/16)  
(2-23/64)  
(1-25/64)  
DC Safety Control Relays with 48...72V, 110...125V or 220...250V DC Electronic Coil  
Cat. No.  
a
b
c
c1  
c2  
Ød  
d1  
d1  
d2  
d2  
45  
105  
119.5  
114.5  
6
2 - 4.5  
60  
35  
700S-CF  
(1-25/32)  
(4-1/8)  
(4-3/4)  
(4-43/64)  
(1/4)  
(2 - 3/16)  
(2-23/64)  
(1-25/64)  
DC Safety Control Relays with Conventional Coil  
Cat. No.  
a
b
c
c1  
c2  
Ød  
45  
81  
145.5  
140.5  
6
2 - 4.5  
60  
35  
700S-CF  
(1-25/32)  
(3-3/16)  
(5-49/64)  
(5-37/64)  
(1/4)  
(2 - 3/16)  
(2-23/64)  
(1-25/64)  
Accessories - 700S-CF Relays  
Safety Control Relays with  
mm  
[in.]  
Auxiliary contact block for side mounting 1- or 2-pole  
Electronic Timing Module on coil terminal side  
Interface Module on coil terminal side  
Surge Suppressor on coil terminal side  
Labeling with label sheet  
a + 9  
b + 24  
b + 9  
b + 3  
+ 0  
(a + 23/64)  
(b + 15/16)  
(b + 23/64)  
(b + 1/8)  
(+ 0)  
Marking tag sheet with clear cover  
+ 0  
(+ 0)  
Marking tag adapter for System Bul. 1492W  
+ 5.5  
(+ 7/32)  
Mounting Position  
AC and DC E Safety Control Relays  
DC Safety Control Relays  
Side View  
Side View  
Front View  
Front View  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
211  
Relay and Timer Specifications  
Safety Relay Circuit With 5 Safety Outputs  
Use for E-stop control. E-stop will work properly if any one fault occurs (a fault could be one welded contact or one undesired open  
connection such as a loose wire).  
High output switching capability and long contact life.  
Circuit complies with EN 954 categories 1, 2, 3, 4.  
Helps prevent restart of the 5 safety outputs if there is a single fault anywhere in the system.  
Use (3) 700S-CF relays and this diagram to construct the circuit  
Basic Circuit  
(1) Output Circuit (3 Relays, 9 Terminal Blocks)  
Start  
Push To Stop  
Pull To Reset  
Included in factory  
wired units  
LOAD 1  
(5) Output Circuit (3 Relays, 17 Terminal Blocks)  
LOAD 2  
LOAD 3  
LOAD 4  
LOAD 5  
*
Numbers shown are the line numbers where the contacts for this relay appear. Contact your local Rockwell Automation sales office or Allen-Bradley distributor for availability.  
212  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
700-K Miniature Control Relays  
IEC compact industrial relay  
IP2X Finger Protection  
Bifurcated contacts for low-level signals  
Optional integrated coil protection diode  
4-Pole AC or DC Coil Voltage  
AC-12  
AC-15 (B600)  
Contacts  
Pkg.  
Connection  
Diagrams  
Ith [A]  
Ie [A]  
Qty.(2)  
Cat. No.  
40 °C 60 °C 24/48V  
120V  
240V  
400V  
500V  
600V  
690V  
N.O.  
N.C.  
4
0
1
1
1
1
700-K40E-⊗  
700-K31Z-⊗  
700-K22Z-⊗  
700-KL22Z-⊗  
3
2
1
2
10  
6
3
3
2
1
1
0.6  
0.6  
1+1L (1) 1+1L  
(1) 1L = Late Break N.C. / Early Make N.O.  
(2) May be ordered in package quantities of 20. Add letter M to the end of the cat. no. Example: 700-K40E-ZJM.  
Coil Voltage Codes  
The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: 230V, 50/60 Hz: Cat. No. 700-  
K40E-becomes Cat. No. 700-K40E-KF. For other voltages, consult your local Rockwell Automation sales office or Allen-Bradley distributor.  
For Screw Type Terminal Versions  
[V]  
12  
24  
KJ  
110  
D
120  
D
125  
ZS  
220  
ZA  
230  
KF  
240  
KA  
250  
ZT  
400  
KN  
440  
B
480  
B
525  
VC  
600  
VC  
AC, 50 Hz  
ZQ  
AC, 60 Hz  
ZD  
AC, 50/60 Hz  
Standard  
ZJ  
DC  
Standard diode  
DJ  
For Spring Clamp Type Terminal Versions  
AC, 50 Hz  
KJ  
D
D
KF  
AC, 60 Hz  
ZD  
AC, 50/60 Hz  
Standard  
ZJ  
DC  
Standard diode  
DJ  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
213  
Relay and Timer Specifications  
Assignment of Contacts  
Device Combinations in Accordance with IEC 60947-1 / -4-1  
Table valid for: AC / DC = 0.85…1.1 x U , T . = -25 °C…+60 °C, normal position (horizontal rail mounting). Also valid for 700-KR relays and  
s
amb  
(3)  
100-KR auxiliary contacts.  
Auxiliary Contact Blocks  
Control Relays 700-K (AC and DC Control)  
700-K31Z- 700-K40E-  
Cat. No.  
Circuit Diagram  
Control  
700-K22Z-  
700-KL22Z-  
43  
47  
21 35  
13  
21 31  
33  
23  
13  
A1  
A1  
13  
43 21  
13  
33 43  
A1  
A1  
22  
22  
36  
A2 14 44  
32  
44  
34  
A2 14 48  
A2 14 34  
22  
A2 14 24  
44  
Front Mounting  
51 61  
100-KFA02E  
AC/DC  
AC/DC  
AC/DC  
AC/DC  
AC/DC  
AC/DC  
AC/DC  
AC/DC  
31Z + 02E = 33Y (1)  
31Z + 11E = 42Y  
31Z + 20E = 51Y  
40E + 02E = 42Y  
40E + 11E = 51Y  
40E + 20E = 60Y  
40E + 04E = 44Y (1)  
40E + 13E = 53Y  
40E + 22Z = 62Y  
40E + 31Z = 71Y (2)  
40E + 40E = 80Y  
52 62  
53 61  
100-KFA11E  
100-KFA20E  
100-KFA04E  
100-KFA13E  
100-KFA22Z  
100-KFA31Z  
22Z + 11E = 33Y  
L22Z + 11E = L33Y  
54 62  
53 63  
22Z + 20E = 42Y  
L22Z + 20E = L42Y  
54 64  
51 61 71 81  
52 62 72 82  
53  
61 71 81  
31Z + 13E = 44Y (1)  
31Z + 22Z = 53Y (1)  
54 62 72 82  
53 83 61  
71  
54 84 62 72  
53 73 83 61  
54 74 84 62  
63 73 83  
53  
100-KFA40E  
22Z + 40E = 62Y  
31Z + 40E = 71Y  
L22Z + 40E = L62Y  
54 64 74 84  
(1) Tamb. max. +40 °C  
(2) Tamb. max. +40 °C and only allowed for coil voltage 24V DC or 230V AC  
(3) For other operating limits, please contact our technical consultant.  
214  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Auxiliary Contact Blocks  
Photo  
Description  
Connection  
Diagrams  
For Use With Pkg.  
Screw Type  
Terminals  
Spring Clamp  
Terminals  
Qty.  
(1)  
N.O.  
N.C.  
Cat. No.  
Cat. No.  
51 61  
100/104-K,  
700-K  
0
2
1
100-KFA02E  
100-KRFA02E  
52 62  
53 61  
100/104-K,  
1
2
0
1
2
3
4
1
0
4
3
2
1
0
1
100-KFA11E  
100-KFA20E  
100-KFA04E  
100-KFA13E  
100-KFA22Z  
100-KFA31Z  
100-KFA40E  
100-KRFA11E  
100-KRFA20E  
100-KRFA04E  
100-KRFA13E  
100-KRFA22Z  
100-KRFA31Z  
100-KRFA40E  
700-K  
54 62  
53 63  
100/104-K,  
700-K  
1
54 64  
Front-mounted auxiliary contacts  
51 61 71 81  
100/104-K,  
700-K  
Auxiliary Contact Blocks  
1
2- and 4-pole versions  
52 62 72 82  
Choice of contact configurations  
Snap on, no tools required  
53  
61 71 81  
100/104-K,  
700-K  
Electronic-compatible bifurcated contacts  
for signals down to 15V / 2 mA  
1
54 62 72 82  
53 83 61  
71  
100/104-K,  
700-K  
1
54 84 62 72  
53 73 83 61  
100/104-K,  
700-K  
1
54 74 84 62  
63 73 83  
53  
100/104-K,  
700-K  
1
54 64 74 84  
(1) May be ordered in package quantities of 10. Add letter M to the end of the cat. no. Example: 100-KFA02EM.  
Control Modules  
Description  
Photo  
Connection  
Diagrams  
For Use With Pkg.  
Qty.  
Cat. No.  
Mechanical Interlock  
For interlocking of two adjacent contactors  
No added width to contactor assembly  
Front mount plug-in type  
Optional auxiliary contact blocks and suppressor modules mount  
onto the interlock  
100/104-K/-  
KR,  
1
100-KMCH  
700-K/- KR  
24…48V AC  
110…280V AC  
380…480V AC  
1 (1) 100-KFSC50  
1 (1) 100-KFSC280  
1 (1) 100-KFSC480  
100/104-K/-  
KR,  
700-K/- KR  
RC Suppressor  
12…55V AC,  
12…77V DC  
1 (1) 100-KFSV55  
1 (1) 100-KFSV136  
1 (1) 100-KFSV277  
SurgeSuppressor  
Plug-in type  
100/104-K/-  
KR,  
56…136V AC,  
78…180V DC  
Limits surge voltage on  
coil drop-off  
MOV Suppressor  
Diode Suppressor  
700-K/- KR  
137…277V AC,  
181…250V DC  
100/104-K/-  
KR,  
700-K/- KR  
12…250V DC  
1 (1) 100-KFSD250  
(1) May be ordered in package quantities of 10. Add letter M to the end of the cat. no. Example: 100-KFSC50M.  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
215  
Relay and Timer Specifications  
Accessories  
Pkg.  
Qty.  
Photo  
Description  
Cat. No.  
Label Sheet  
105 self-adhesive paper labels each, 6 x 17 mm  
10  
100-FMS  
Snap-In Marker Card  
5
1492-M6X12  
216  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
IEC Specifications - 700-K... Relays  
700-K  
700-KR  
AC-12 Rated Thermal Current Ambient temperature 40°C  
I
24…240V  
230…500V  
230…690V  
[A]  
[A]  
[A]  
10  
10  
10  
th  
Ambient temperature 60°C  
I
24…240V  
230…500V  
230…690V  
[A]  
[A]  
[A]  
6
6
6
th  
AC-15/B600 Switching of Solenoids and contactors  
I
24V  
48V  
[A]  
[A]  
[A]  
[A]  
[A]  
[A]  
[A]  
[A]  
[A]  
[A]  
3
3
e
120V  
230V  
240V  
400V  
480V  
500V  
600V  
690V  
3
2
2
1.2  
1
1
0.6  
0.6  
Short-circuit Protection  
Fuse gG  
[A]  
10  
2
Min. Switching Capacity 15V  
[mA]  
Resistance and Power Dissipation  
Main current circuit resistance, 1 pole  
Power dissipation, 4 poles  
[mΩ]  
6.5  
2.6  
[W]  
Total power dissipation  
AC control, warm  
DC control, warm  
[W]  
[W]  
4.4  
5.2  
Lifespan  
Mechanical  
[Mio. op.]  
[Mio. op.]  
15  
Electrical AC-15 (240V / 2 A)  
Weight  
0.7  
AC control  
DC control  
kg (lbs.)  
kg (lbs.)  
0.16 (0.35)  
0.2 (0.44)  
Load Carrying Capacity per UL/CSA  
Rated voltage  
AC  
40 °C  
AC  
[V]  
[A]  
[A]  
[V]  
[A]  
max. 600  
Continuous rating  
Switching capacity  
Rated voltage  
10  
6
B 600  
max. 600  
Q 600  
DC  
Switching capacity  
DC  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
217  
Relay and Timer Specifications  
700-K  
DC-13/Q600  
1 pole  
24V  
48V  
[A]  
[A]  
[A]  
[A]  
[A]  
[A]  
[A]  
[A]  
[A]  
2.3  
1
110V  
125V  
220V  
250V  
400V  
440V  
600V  
0.55  
0.55  
0.27  
0.27  
0.15  
0.15  
0.1  
Cross Sections  
Conductor Cross Sections  
700-K  
700-KR  
- Main Contacts, Auxiliary Contacts, and Coil Terminals  
(1)  
Terminal type  
2
(1) Conductor  
Fine stranded with ferrule  
(2) Conductors  
[mm ]  
0.75…2.5  
0.75…2.5  
0.50…2.5  
0.50…2.5  
[mm2]  
0.75…2.5 (3)  
0.75…2.5 (3)  
2
(1) Conductor  
Solid or coarse stranded  
[mm ]  
1…4  
1…2.5 + 1…4  
(2) Conductors  
[mm2]  
Recommended torque  
Cross section per UL/CSA  
Recommended torque  
[Nm]  
[AWG]  
[lb-in]  
1.2  
18…12 (2)  
10.6  
18…14 (3)  
(1) Pozidriv No. 2 / Blade No. 3 screw  
(2) Use same cross sections  
(3) Stranded wire only  
218  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Coil Data  
700-K  
Operating Limits  
pick-up  
dropout  
[x Us]  
[x Us]  
0.85…1.1  
0.2…0.75  
0.8…1.1  
AC control  
50 Hz, 60 Hz, 50/60 Hz  
pick-up  
dropout  
[x Us]  
[x Us]  
9, 12, 24, 110V DC: 0.7…1.25  
DC control  
0.1…0.75  
Coil Consumption  
pick-up  
hold-in  
pick-up  
hold-in  
[VA/W]  
[VA/W]  
[W]  
35/32  
AC control  
50 Hz, 60 Hz, 50/60 Hz  
5/1.8  
cold 3.0, warm 2.6  
cold 3.0, warm 2.6  
DC control  
Operating Times  
AC  
[W]  
closing delay  
opening delay  
opening delay  
closing delay  
opening delay  
closing delay  
opening delay  
[ms]  
[ms]  
[ms]  
[ms]  
[ms]  
[ms]  
[ms]  
15…40  
15…33  
15…28  
18…40  
6…12  
With RC module  
DC  
With integrated diode  
With external diode  
8…12  
35…50  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
219  
Relay and Timer Specifications  
Dimensions - 700-K... Relays  
Approximate dimensions are shown in millimeters. To convert millimeters to inches multiply by 0.0394. Dimensions are not intended to be used for  
manufacturing purposes.  
(mm)  
180°  
)
12  
*
35  
45  
4
35.2  
49  
)
-Minimum distance to grounded parts or walls  
*
79  
220  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Solid-state Relays  
Product Overview  
Bulletin No.  
Type  
700-SA  
700-SC  
Tube Base, Socketed  
Miniature, Ice Cube Socketed  
Compatible with 700-HN100, 125,108, and 204 socket, LED Compatible with 700-HN103 or 128 socket, LED Status, and Zero-  
Features  
status, zero-cross switching  
cross AC Switching Options  
AC  
Load Type  
DC  
AC (47…63 Hz)  
DC  
(47…63 Hz)  
Load Voltage Range  
75…264V AC  
5 A  
3…125V DC  
3 A  
75…264V AC  
3 A  
3…52.8V DC or 3…125V DC  
3 A @ 48V DC or 2 A @ 110V DC  
Load Current Max. (Continuous)  
10 mA @ 200V AC, 5 mA @ 50V DC  
or 0.1 mA @ 100V DC  
Max. Leakage Current to Load  
Zero Cross Load Switching  
5 mA @ 100V, 10 mA @ 200V  
5 mA @ 125V  
5 mA @ 100V AC  
Yes (optional)  
Form A  
Yes  
Not Applicable  
Not Applicable  
Equivalent Electromechanical Relay  
Contact Arrangement  
Form A  
5…24V DC, 100…110V  
AC, 200/220V AC  
Rated Control (Input) Voltage  
5…24V DC  
5...24V DC  
LED Indicator  
Yes  
Yes (optional)  
Yes (optional for 48V DC)  
Mounting Method  
Dielectric Strength  
Certification  
Panel or DIN with socket  
1500V AC, 50/60 Hz, 1 min.  
cURus, CE, VDE  
Panel or DIN with socket  
1500V AC, 50/60 Hz, 1 min.  
cURus, CE, VDE  
Max. Ambient Operating Temperature  
Page  
-30…80 °C (no condensation)  
223  
-30…80 °C (no condensation)  
228  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
221  
Relay and Timer Specifications  
Product Overview  
Bulletin No.  
Type  
700-SF  
700-SH  
700-SK  
Square Base, Socketed  
Hockey Puck  
Slim Line, Socketed  
Compatible with 700-HN116 socket,  
LED status, zero-cross AC switching  
Panel/DIN Mount, High Current,  
Protective Cover, LED Status  
Compatible with 700-HN121 socket. Supports Input (sensor) module or  
Output (SSR) module  
Features (1)  
Output Module  
Input Module  
AC (47…63 Hz)  
3…60V DC  
Load Type  
AC (47…63 Hz)  
DC  
AC  
DC  
AC (47…63 Hz) DC  
(47…63 Hz)  
3…50V DC, 24…265V AC  
42…530V AC, 42…265V AC,  
42…660V AC  
4 … 60V  
DC, 40 …  
200V DC  
Load Voltage  
Range  
Field Input: 60… Field Input:  
75…264V AC  
3 A  
3 … 52.8V DC  
75 … 264V AC  
2 A  
264V AC  
6.6… 32V DC  
Load Current  
Max.  
(Continuous)  
2 A @ 60V,  
1.5 A @  
200V  
Supply Current:  
0.1…100 mA  
Supply Current:  
0.1…100 mA  
10 A/100 A‡  
<3 mA  
Yes  
Max. Leakage  
Current to  
Load  
5 mA @ 100V AC,  
10 mA @ 200V AC  
5 mA @ 50V DC  
Not Applicable  
1.5 mA  
1 mA  
N/A  
5 μA  
5 μA  
Zero Cross  
Load  
Yes  
Yes (optional)  
No  
N/A  
Switching  
Equivalent  
Electromecha  
nical Relay  
Contact  
Form A  
Form A  
Form A  
Arrangement  
Rated Control  
(Input)  
Voltage  
3…32V DC, 4…32V DC,  
80…130V AC, 20…260V AC  
20…280V AC/22…48V DC  
4V DC or 24V DC  
5… 24 V DC  
Yes  
LED Indicator Yes  
Yes  
Mounting  
Method  
Panel without heat sink, Panel, or DIN  
with heat sink  
Panel or DIN with socket  
1500V AC, 50/60 Hz, 1 min.  
Panel or DIN with socket  
Dielectric  
Strength  
>4000V AC RMS  
cURus, CE, CSA  
4000V AC, 50/60 Hz, 1 min.  
cURus, CE, TÜV  
Certification cURus, CE, VDE  
Max. Ambient  
Operating  
Temperature  
-30…80 °C (no condensation)  
-20…70 °C (no condensation)  
237  
-30…80 °C (no condensation)  
246  
Page  
233  
(1) See Solid-state Relay Glossary on page 223 for term definitions.  
222  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Solid-state Relay Glossary  
Terms  
Meaning  
Basic insulation  
Insulation for basic protection from electric shock (IEC950 1.2.9.2)  
Independent insulation that is provided outside of basic insulation to protect from electric shock when the basic  
insulation breaks down (IEC950 1.2.9.3)  
Supplemental insulation  
Reinforced insulation  
Insulation  
A single-layer of insulation (IEC950 1.2.9.5) that provides the same protection from electric shock as double insulation  
(insulation including both basic and supplemental insulation) according to conditions stipulated in IEC950 standards  
Zero cross circuit  
Trigger circuit  
A circuit that starts operation with the AC load voltage at close to zero-phase.  
Circuit functions  
A circuit for controlling the triac or thyristor trigger signal, which turns the load current ON and OFF.  
If the external circuit is prone to generating noise, or if wires from external sources are prone to the influence of  
inductive noise, in order to prevent malfunctions due to noise, it is necessary to electrically isolate internal circuits and  
external circuits (output circuits). An isolated input circuit is a circuit that isolates inputs and outputs by using  
components that are not connected electrically but that can transmit signals, such as contact relays or photocouplers.  
Isolated input circuit  
A component that runs the electric signal into a light emitter (for example, LED), changes it to a light signal, and then  
returns it to an electric signal using a photoelectric conversion element, such as a photo transistor. The space that is  
used for transferring the light signal is isolated thus providing good insulation and a high propagation speed.  
Photocoupler  
Rated voltage  
The voltage that serves as the standard value of an input signal voltage  
Input  
Pickup (must-operate) voltage Minimum input voltage when the output status changes from OFF to ON.  
The impedance of the input circuit and the resistance of current-limiting resistors used. Impedance varies with the  
Input impedance  
input signal voltage in case of the constant current input method.  
The permissible voltage range within which the voltage of an input signal voltage may fluctuate.  
Maximum input voltage when the output status changes from ON to OFF.  
The current value when the rated voltage is applied.  
Operating voltage  
Dropout (Reset) voltage  
Input current  
This is the effective value for the power supply voltage that can be used for load switching or in the continuous-OFF  
state.  
Load voltage  
The effective value of the maximum current that can continuously flow into the output terminals under specified  
cooling conditions (i.e., the size, materials, thickness of the heat sink, and an ambient temperature radiating  
condition).  
Maximum load current  
(continuous)  
The effective value of the current that can flow into the output terminals when a specified load voltage is applied to  
the SSR with the output turned OFF.  
Leakage current  
The effective value of the AC voltage that appears across the output terminals when the maximum load current flows  
through the SSR under specified cooling conditions (such as the size, material, and thickness of heat sink, ambient  
temperature radiation conditions, etc.).  
Output ON voltage drop  
Output  
Minimum load current  
(continuous)  
The minimum load current at which the SSR can operate normally.  
A circuit consisting of a resistor R and capacitor C, which prevents faulty ignition from occurring in the SSR triac by  
suppressing a sudden rise in the voltage that is applied to the triac.  
Snubber circuit  
Semiconductor output  
This is a generic name for semiconductors such as the thyristor, triac, power transistor, and power MOS FET. In  
element (switching element) particular, triacs are often used in SSRs because they allow switching to be performed with one element.  
Repetitive peak OFF-state  
This is a rating for an output semiconductor that used in an SSR for AC loads.  
voltage (VDRM)  
Collector-emitter voltage  
This is a rating for an output semiconductor that used in an SSR for DC loads.  
(VCEO)  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
223  
Relay and Timer Specifications  
Terms  
Meaning  
A time lag between the moment a specified signal voltage is imposed to the input terminals and the output is turned  
ON.  
Operating (pick-up) time  
Release (drop-out) time  
Insulation resistance  
A time lag between the moment the imposed signal input is turned OFF and the output is turned OFF.  
The resistance between the input and output terminals or I/O terminals and metal housing (heat sink) when DC  
voltage is imposed.  
Characteristics  
The effective AC voltage that the SSR can withstand when it is applied between the input terminals and output  
terminals or I/O terminals and metal housing (heat sink) for more than 1 minute.  
Dielectric strength  
Ambient temperature and  
humidity (operating)  
The ranges of temperature and humidity in which the SSR can operate normally under specified cooling, input/output  
voltage, and current conditions.  
Storage temperature  
The temperature range in which the SSR can be stored without voltage imposition.  
A current, which can be applied for short periods of time to the electrical element.  
Extremely steep voltage rise which occurs when the load switched or turned OFF.  
Inrush current resistance  
Counter-electromotive force  
The recommended load capacity which takes into account the safety factors of ambient temperature and inrush  
current.  
Others  
Recommended applicable load  
Bleeder resistance  
The resistance connected in parallel to the load in order to increase apparently small load currents, so that the ON/OFF  
of minute currents functions normally. (It is also used to shunt leakage currents.)  
Solid-state Relay Switching Capacity  
Maximum AC and DC Switching Capability  
Equivalent EM  
Relay Contact  
Conguration  
Load  
Load  
Voltage  
Relay Type  
Zero-Cross Switching 1 mA 10 mA 50 mA 100 mA 1 A  
3 A  
5 A  
10 A 20 A 25 A 30 A 35 A  
100 A  
Device  
AC  
DC  
AC  
DC  
AC  
DC  
AC  
DC  
AC  
DC  
Yes  
N/A  
Yes  
N/A  
Yes  
N/A  
Yes  
N/A  
Yes  
N/A  
Triac  
Transistor  
Triac  
Form A  
Form A  
700-SA  
700-SC  
Transistor  
Triac  
(2 A)  
700-SF  
Form A  
Form A  
Transistor  
Thyristor  
or Triac  
Transistor  
700-SH *  
Triac  
(2A)  
700-S KO  
Form A  
Transistor  
IMPORTANT * Requires a heat sink to reach maximum current value.  
224  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
700-SA Tube Base Relays  
5 A (resistive) max. continuous load (output) current  
264V AC or 125V DC max. load voltage options  
Photocoupler isolation between control and load voltage  
LED indicator (standard) for input/logic ON/OFF status monitoring  
700-HN100, -HN125, -HN 202, or -HN108 specialty socket compatible  
700-HT2 timing module  
Input-to-Output Isolation  
Method  
Output (Load) Max. Continuous  
Current and Rated Voltage Range Voltage  
Rated Input (Control)  
Zero Cross Function Status Indicator  
Cat. No.  
5 A @ 100…240V AC  
Yes  
700-SAZY5Z25  
700-SANY3Z25  
(47…63 Hz)  
Photocoupler  
Yes  
5…24V DC  
Not Applicable  
3 A @ 5…110V DC  
Accessories - 700-SA Relays  
Photo  
Description  
Pkg. Quantity  
Cat. No.  
10  
700-HN100  
Screw Terminal Tube Base Socket — Panel or DIN Rail Mounting; Guarded Terminal Construction.  
8 Pin for use with DPDT 700-HA Relays.  
10  
10  
700-HN108  
700-HN125  
Specialty Socket  
8 Pin back wired socket with solder terminals  
Screw Terminal Tube Base Socket — Panel or DIN Rail Mounting; Open Style Construction. 8 Pin  
for use with DPDT 700-HA Relays. No retainer clip required.  
10  
199-DR1  
DIN (#3) symmetrical hat rail  
35 x 7.5 x 1 m  
Pre-Printed Identification Tags — contains 10 sheets of pre-printed and blank tags. Each sheet contains  
13 sets of the markings CR…9CR, TR…9TR, M…9M, F, R, 1S, and 117 blank tags. Tags are peel-off with  
sticky backing for easy placement on relays.  
10  
10  
10  
700-N40  
Blank Identification Tags — contains 10 sheets of blank identification tags for customer specialized  
printing. Each sheet contains 546 blank tags. Tags are peel-off with sticky backing for easy placement on  
relays.  
700-N41  
700-HN158  
Retainer Clip for Sockets with 700-SA AND 700-HB Relays. Secures relay in socket.  
10  
700-HN204  
8-Pin Socket — Can Be Used With or Without Timing Module or Surge Suppressor. Screw Terminal  
Tube Base Sockets — panel or DIN Rail mounting. Guarded terminal construction. Used with DPDT 700-HA  
Relays.  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
225  
Relay and Timer Specifications  
Specifications - 700-SA Relays  
Control/Input Ratings  
Cat. No.  
Rated Control  
Max. Operating  
Control  
Max. Reverse  
Control  
Impedance  
Control Voltage Levels  
Voltage  
Pick-up Voltage  
Drop-out Voltage  
Voltage Range  
Voltage  
(1)  
700-SAZY5Z25  
700-SANY3Z25  
4…32V DC  
4…30V DC  
-32V DC  
-30V DC  
15 mA max.  
5…24V DC  
4V DC max.  
1V DC min.  
1.5 kΩ (+20% -10%)  
Load/Output Ratings  
Cat. No.  
Rated Load  
Voltage  
Maximum Load  
Continuous Load Current (Resistive) [A]  
(2)  
Max. Inrush  
(3)  
Voltage Range  
Current  
Min.  
0.1  
Max.  
5.0  
80 A, @ 50/60 Hz for 1  
cycle  
700-SAZY5Z25  
700-SANY3Z25  
100…240V AC  
5…110V DC  
75…264V AC  
3…125V DC  
0.1  
3.0  
12 A (10 ms)  
Characteristics  
Description  
Cat. No. 700-SAZY5Z25  
Triac  
Cat. No. 700-SANY3Z25  
Load Switching Method/Device  
Pick-up Time  
Transistor  
(4)  
1/2 cycle of load power source cycle time + 1 ms max.  
0.5 ms max.  
(4)  
Drop-out Time  
1/2 cycle of load power source cycle time + 1 ms max.  
2.5 ms max.  
Output ON Voltage Drop  
Output Leakage Current  
1.6V (RMS) max.  
1.5V max.  
5 mA max. (at 100V AC); 10 mA max. (at 200V AC)  
5 mA max. (at 125V DC)  
Output V  
V
(V)  
600  
50  
150  
150  
DRM CEO  
Output di/dt (V/uS)  
Output dv/dt (V/uS)  
500  
41.6  
125  
2
2
Output I t (A S)  
Output Tj (ºC) Max.  
Insulation Resistance  
Dielectric Strength  
100 MΩ min. (at 500V DC)  
1500V AC, 50/60 Hz for 1 min  
Vibration Resistance (Max.)  
Shock Resistance (max.)  
10…55 Hz, 1.5 mm double amplitude (10 G)  
2
1000 m/s (100 G)  
Operating  
Storage  
–30…80 °C (–22…176 °F) with no icing or condensation  
–30…100 °C (–22…212 °F) with no icing or condensation  
45…85% (no condensation)  
Ambient Temperature  
Ambient Humidity  
Standards Compliance  
Certifications  
UL 508, CSA C22.2 No. 14, EN 60947-1, -4-3  
cURus Recognized (File No. E96956, Guide NMFT2/NMFT8), CE Marked, VDE Certified  
Approx. 70 g  
Weight  
(1) With constant current input system. SSR input impedance varies with a change in input (control) voltage.  
(2) See the following graph “Load Current Vs. Ambient Temperature Characteristics”for additional load current details.  
(3) If the SSR operation is continuous ON/OFF, this value should be reduced by 50%. See “Inrush Current Resistivity”graph.  
(4) 60 Hz full cycle time = 16.6 ms, 50 Hz full cycle time = 20 ms.  
(1)  
Load Current vs. Ambient Temperature Characteristics  
Inrush Current Resistivity  
700-SA  
700-SA  
80  
700-SAZY5Z25  
5
70  
60  
4
50  
40  
700-SANY3Z25  
3
700-SAZY5Z25  
700-SANY3Z25  
30  
20  
10  
0
2
1
0
Energizing Time [ms]  
Ambient Temperature [° C]  
(1) Inrush current resistivity is the ability of an SSR to withstand a large surge current for a short period. Surges are considered non-repetitive (max. repeatability once every 5 seconds). Keep the inrush current to half the rated value if it  
occurs repetitively. Exceeding the non-repetitive inrush current will damage the SSR.  
226  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Terminal Arrangement (Bottom View)  
Load  
Load  
Load  
power  
supply  
Input  
Input voltage  
Note: The plus and minus symbols shown in parentheses  
are for DC loads.  
Basic Application Considerations  
High Density Mounting of Multiple Solid-state Relays (SSRs)  
If multiple SSRs are installed side by side,, the outer case wall of the SSR serves to dissipate heat. Install the relays so that they are adequately  
ventilated. If poor ventilation is unavoidable, reduce the load current to half.  
Protective Component  
When controlling AC inductive loads, connect an inrush/surge absorbing device (varistor) across the SSR load terminals. If the SSR has built- in  
surge suppression (s 700-SE and 700-SH) and additional surge suppression is required, connect the varistor across the terminals of the load device.  
Select a varistor that meets the conditions of the load voltage that is outlined in the table.  
Load Voltage  
100…120V AC  
200…240V AC  
380…480V AC  
Varistor Voltage [V]  
240…270  
Varistor Surge Resistance  
440…470  
1000 A min.  
820…1000  
TIP For additional details on solid-state relays, see the Solid-State Relay Application Guide, publication 700-AT001.  
For a DC inductive load, a diode should be connected parallel to the load to absorb the counter electromotive force (OFF) of the load.  
EMC Directive Compliance  
1. AC-switching models comply with EMC Directives  
under the following conditions:  
Load  
Load power  
supply  
3 m max.  
Input  
SSR  
Load  
Input 700-SA Output  
Varistor  
Film Capacitor  
Varistor: 470 V, 0.6 W  
Film Capacitor: 1µ F, 250 VAC  
• Connect a varistor between the output terminals.  
• Connect a film capacitor to the load power supply.  
• The input cable must be less than 3 m.  
2. DC-switching models comply with EMC Directives  
under the following conditions:  
Less than 10 m  
Input  
Load  
700-SA Output  
• The input cable must be less than 10 m.  
Dimensions - 700-SA Relays  
All units in millimeters unless otherwise indicated. To convert millimeters to inches multiply by 0.0394. Dimensions are not intended to be used for  
manufacturing purposes.  
(1)  
700-SA  
+
35  
max.  
+
52.5  
max.  
35  
max.  
(1) 700-SA is compatible with Cat. Nos. 700-HN100, -108, -125, and -204 (sockets).  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
227  
Relay and Timer Specifications  
700-SC Ice Cube Relays  
3 A (resistive) max. continuous load (output) current  
264V AC, 48V DC or 125V DC max. load voltage options  
5…24V DC or 110/220V AC control (input) voltage options  
LED indicator (optional) for input/logic On/Off status monitoring  
700-HN103, 700-HN104, or 700-HN128 socket compatible  
Compatible with 700-AT1 or 700-AT2 timer modules  
Input-to-Output Isolation  
Method  
Output (Load) Max. Continuous  
Current and Rated Voltage Range Voltage  
Rated Input (Control)  
Zero Cross Function Status Indicator  
Cat. No.  
3 A @ 100…240V AC(1)  
2 A @ 100…240V AC(1)  
5…24V DC  
100/110V AC  
200/220V AC  
24V DC  
700-SCZY3Z25  
700-SCZY2A1  
700-SCZY2A2  
700-SCTY3Z24  
700-SCNY3Z25  
700-SCZN3Z26  
700-SCTN3Z24  
700-SCNN3Z26  
700-SCNN2Z25  
Photocoupler  
Yes  
Yes  
Phototriac  
Photocoupler  
Phototriac  
No  
3 A @ 100…240V AC (1)  
3 A @ 4…48V DC  
Not Applicable  
Yes  
5…24V DC  
4…24V DC  
24V DC  
(1)  
3 A @ 100…240V AC  
No  
No  
3 A @ 4…48V DC  
2 A @ 5…110V DC  
4…24V DC  
5…24V DC  
Photocoupler  
(1) 47…63 Hz  
Not Applicable  
Accessories - 700-SC Relays  
Photo  
Description  
Pkg. Quantity Cat. No.  
Screw Terminal Socket — Panel or DIN Rail Mounting; Guarded Terminal Construction.Ith  
=
=
10  
10  
700-HN103  
700-HN104  
10 A per pole. 14-blade miniature socket for use with 700-SC Relays.  
Screw Terminal Socket — Panel or DIN Rail Mounting; Guarded Terminal Construction Ith  
10 A per pole. 14-blade miniature socket for use with 700-SC relays. This socket has coil and  
contact separation and the ability to plug in optional plug-in modules (700-A__ accessories: LED,  
Surge Suppression, Timing Modules)  
Screw Terminal Base Socket — Panel or DIN Rail Mounting; Open-Style Construction Ith  
=
10  
10  
700-HN128  
199-DR1  
10 A per pole. 14-blade miniature socket for use with 700-SC Relays.  
DIN (#3) symmetrical hat rail  
35 x 7.5 x 1 m  
228  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Photo  
Description  
Pkg. Quantity Cat. No.  
Pre-Printed Identification Tags — contains 10 sheets of pre-printed and blank tags. Each  
sheet contains 13 sets of the markings CR…9CR, TR…9TR, M…9M, F, R, 1S, and 117 blank tags. 10  
Tags are peel-off with sticky backing for easy placement on relays.  
700-N40  
Blank Identification Tags — contains 10 sheets of blank identification tags for customer  
specialized printing. Each sheet contains 546 blank tags. Tags are peel-off with sticky backing for 10  
easy placement on relays.  
700-N41  
(1)  
Retainer Clip for Cat. Nos. 700-HN103, -HN104, and -HN128 Sockets with 700-HC  
Relays. Secures relay in socket.  
10  
700-HN114  
(1) Series B retainer clip must be used with 700-SC  
Specifications- 700-SC Relays  
Control/Input Ratings  
Cat. No.  
Rated Control  
Voltage  
Max. Operating  
Control Voltage  
Range  
Max. Reverse  
Control Voltage [V]  
Impedance  
Control Voltage Levels  
Pick-up Voltage  
Drop-out Voltage  
700-SCZY3Z25  
700-SCZY2A1  
700-SCZY2A2  
700-SCTY3Z24  
5…24V DC  
100/110V AC  
200/220V AC  
24V DC  
4…28V DC  
75…125V AC  
150…250V AC  
19.2…28.8V DC  
-28.8  
NA  
15mAmax.(1)  
41 kΩ 20%  
72 kΩ 20%  
2 kΩ 20%  
4V DC max.  
75V AC max.  
150V AC max.  
19.2V DC max.  
1V DC min.  
20V AC min.  
40V AC min.  
NA  
-28.8  
1.5 kΩ +20%/ -10%  
700-SCNY3Z25  
5…24V DC  
4…28V DC  
-28  
4V DC max.  
(2)  
700-SCZN3Z26  
700-SCTN3Z24  
700-SCNN3Z26  
700-SCNN2Z25  
Load/Output Ratings  
Cat. No.  
4…24V DC  
24V DC  
3…28V DC  
-28.8  
-28.8  
-28  
15mAmax. (1)  
3V DC max.  
1V DC min.  
19.2…28.8V DC  
2 kΩ 20%  
19.2V DC max.  
4…24V DC  
5…24V DC  
1.5 kΩ +20%/ -10%  
3…28V DC  
3V DC max.  
(2)  
-28.8  
Rated Control  
Voltage  
Max. Load  
Continuous Load Current (Resistive) [A]  
Max. Inrush  
Current (4)  
Min.  
Max. (3)  
Voltage Range  
700-SCZY3Z25  
700-SCTY3Z24  
700-SCZN3Z26  
700-SCTN3Z24  
700-SCZY2A1  
700-SCZY2A2  
700-SCNN3Z26  
700-SCNY3Z25  
700-SCNN2Z25  
0.1  
3
45 A (@50/60 Hz,  
1 cycle)  
100…240V AC  
75…264V AC  
0.1  
2
4…48V DC  
3…52.8V DC  
3…125V DC  
0.1  
0.1  
3
2
18 A (10 ms)  
10 A (10 ms)  
5…110V DC  
(1) With constant current input circuit system. SSR impedance varies with a change in input (control) voltage.  
(2) Input impedance attains its maximum at the operating voltage.  
(3) If the SSR operation is continuous ON/OFF, this value should be reduced by 50%. See “Inrush Current Resistivity”graphs on page 112 for details  
(4) See the following “Load Current Versus Ambient Temperature Characteristics”graphs on page 112 for additional load current details.  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
229  
Relay and Timer Specifications  
Characteristics  
Description  
Cat. No. 700-SCZ…  
Cat. No. 700-SCT  
Cat. Nos. 700-SCNY, 700-  
SCNN3…  
Cat. Nos. 700-SCNN2…  
Load Switching Method/Device  
Triac  
Transistor  
1/2ofloadpowersourcecycle  
time (1) + 1 ms max. (DC  
input)  
Pick-up time  
3/2ofloadpowersourcecycle  
(1)  
time + 1 ms max. (AC  
input)  
1/2 of load power source cycle  
(1)  
time + 1 ms max. (DC input)  
3/2 of load power source cycle  
1/2 of load power source cycle  
Drop-out time  
2 ms max.  
2.5 ms max.  
(1)  
time + 1 ms max.  
(1)  
time + 1 ms max. (AC input)  
Output On Voltage Drop  
Output Leakage Current  
1.6V (RMS) max.  
1.6V (RMS)  
1.5V max.  
1.5V max.  
5 mA max (@ 100V AC)  
10 mA max (@ 200V AC)  
2.5 mA max (@ 100V AC)  
5 mA max (at 200V AC)  
5 mA max (@ 50V DC)  
0.1 mA max (@ 100V DC)  
Output V , V (V)  
600  
50  
600  
50  
80  
150  
80  
150  
DRM CEO  
Output di/dt (A/uS)  
Output dv/dt (V/uS)  
250  
18  
250  
18  
2
2
Output I t (A S)  
Output Tj (°C) Max.  
125  
125  
Insulation Resistance  
Dielectric Strength  
100 MΩ min (@500V DC)  
1500V AC, 50/60 Hz for 1 minute  
Vibration Resistance (max.)  
Shock Resistance (max.)  
10…55 Hz, 1.5 mm double amplitude (10 G)  
2
1000 m/s (100 G)  
Operating: -30…+80 °C (-22...+176 °F) with no icing or condensation Storage: -30…+100 °C (-22...+212 °F) with no icing or  
condensation  
Ambient Temperature  
Standards Compliance  
Certifications  
UL 508, CSA C22.2 No. 14, EN/IEC 60950, EN 50011, EN 61000-6-2, EN/IEC 60947-1, -4-3  
cURus Recognized (File No. E96956, Guide NMFT2/NMFT8), CE Marked, VDE Certified  
Operating: 45…85% (no condensation)  
Ambient Humidity  
Weight  
Approx. 50 g  
(1) 60 Hz full cycle time = 16.6 ms, 50 Hz full cycle time = 20 ms  
Load Current Versus Ambient Temperature Characteristics  
7±±-SC_ _3...  
7±±-SC_ _2...  
5
4
5
4
3
2
3
2
1
0
1
0
Ambient Temperature [° C]  
Ambient Temperature [° C]  
230  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
(1)  
Inrush Current Resistivity  
7±±-SCNN3...  
7±±-SCNY3  
7±±-SCZ....  
7±±-SCT...  
7±±-SCNN2...  
30  
12  
10  
50  
40  
30  
20  
28  
26  
24  
22  
20  
18  
16  
14  
12  
10  
8
8
6
4
2
6
4
10  
0
2
0
0
Energizing Time [ms]  
Energizing Time [ms]  
Energizing Time [ms]  
(1) Inrush current resistivity is the ability of an SSR to withstand a large surge current for a short period. Surges are considered non-repetitive (max. repeatability once every 2…5 seconds). Keep the inrush current to half the rated  
value if it occurs repetitively. Exceeding the non-repetitive inrush current will damage the SSR.  
EMC Directive Compliance  
1. AC-switching models comply with EMC Directives under the  
following conditions  
3 m max.  
Load  
Input  
700-SC Output  
Varistor  
Film capacitor  
Varistor: 470 V, 0.6 W  
Film capacitor: 1  
µF, 250 VAC  
• Connect a varistor between the output terminals.  
• Connect a film capacitor to the load power supply.  
• The input cable must be less than 3 m.  
2. DC-switching models comply with EMC Directives under the  
following conditions  
Less than 10 m  
Load  
Input  
700-SC  
Output  
• The input cable must be less than 10 m.  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
231  
Relay and Timer Specifications  
Dimensions - 700-SC Relays  
All units in millimeters unless otherwise indicated. To convert millimeters to inches multiply by 0.0394. Dimensions are not intended to be used for  
manufacturing purposes.  
Terminal Arrangement/  
Internal Connections  
(Bottom View)  
1
5
4
8(+)  
(+)  
(–)  
28 max.  
Load  
Load  
power  
supply  
Load  
Input  
9
12(–)  
13  
14  
+
36.5 max.  
42.5 max.  
21.5 max.  
+
Input voltage  
Note: The plus and minus symbols shown  
in parentheses are for DC loads.  
(1)  
Cat. No 700-SC…  
(1) 700-SC is compatible with Cat. Nos. 700-HN103, -HN104, and -HN128 socket.  
Basic Application Considerations for 700-SC  
High-density Mounting of Multiple Solid-state Relays (SSRs)  
If multiple relays are mounted side by side, the outer wall of each SSR works as a radiator. The SSR casing serves to dissipate heat. Install the relays so  
that they are adequately ventilated. If poor ventilation is unavoidable, reduce the load current by half.  
Connection  
For DC Load Switching, 700-SC will operate properly if the load is connected to either the positive or negative SSR load terminal.  
Protective Component  
When controlling AC inductive loads, connect an inrush/surge absorbing device (varistor) across the SSR load terminals. If the SSR has built- in  
surge suppression (s 700-SE and 700-SH) and additional surge suppression is required, connect the varistor across the terminals of the load device.  
Select a varistor that meets the conditions of the load voltage that is outlined in the table below.  
Load Voltage [V AC]  
100…120  
Varistor Voltage [V]  
240…270  
Varistor Surge Resistance  
200…240  
440…470  
1000 A min.  
380…480  
820…1000  
TIP For additional details on solid-state relays, see the Solid-State Relay Application Guide, publication 700-AT001.  
Load  
Load power  
supply  
Input  
SSR  
232  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
700-SF Square Base Relays  
3 A (resistive) max. continuous load (output) current  
264V AC or 52.8V DC max. load voltage options  
4…24V DC control/input voltage  
Photocoupler or phototriac isolation option between control and output voltage  
LED Indicator for input/logic ON/OFF status monitoring  
700-HN116 socket compatible  
Output (Load)  
Max. Continuous Current and  
Rated Voltage Range  
Input-to-Output Isolation  
Method  
Rated Input Control  
Voltage  
Zero Cross Function Status Indicator  
Cat. No.  
Photocoupler  
Phototriac  
Yes  
5…24V DC  
24V DC  
700-SFZY3Z25  
700-SFTY3Z24  
700-SFNY3Z25  
3 A @ 100…240V AC  
(47...63 Hz)  
No  
Yes  
Photocoupler  
Not Applicable  
3 A @ 4…48V DC  
4…24V DC  
Accessories-700-SF Relays  
Description  
Pkg. Quantity  
Cat. No.  
Photo  
Screw Terminal Socket — Panel or DIN Rail Mounting 8-blade miniature socket for use with DPDT HF relays.  
10  
10  
700-HN116  
DIN (#3) symmetrical hat rail  
35 x 7.5 x 1 m  
199-DR1  
Pre-Printed Identification Tags — contains 10 sheets of pre-printed and blank tags. Each sheet contains 13 sets  
of the markings CR…9CR, TR…9TR, M…9M, F, R, 1S, and 117 blank tags. Tags are peel-off with sticky backing for 10  
easy placement on relays.  
700-N40  
Blank Identification Tags — contains 10 sheets of blank identification tags for customer specialized printing.  
Each sheet contains 546 blank tags. Tags are peel-off with sticky backing for easy placement on relays.  
10  
700-N41  
Retainer Clip for Cat. Nos. 700-HN103, -HN104, and -HN128 Sockets with 700-HC Relays. Secures relay in  
socket.  
10  
700-HN114(1)  
(1) 700-SF must use Cat. No. 700-HN114 series B retainer clip.  
Specifications- 700-FS Relays  
Control/Input Ratings  
Cat. No.  
Rated Control  
Voltage  
Max. Operating  
Control Voltage  
Range [V DC]  
Max. Reverse  
Control Voltage [V]  
Impedance  
Control Voltage Levels  
Pick-up Voltage  
Drop-out Voltage  
(1)  
700-SFZY3Z25  
700-SFTY3Z24  
5…24V DC  
24V DC  
4…28V DC  
–32  
15 mA max.  
4V DC max.  
1V DC min.  
1V DC min.  
19.2…28.8V DC  
–28.8  
2 kΩ 20%  
19.2V DC max.  
1.5 k  
Ω
+ 20%/–  
700-SFNY3Z25  
5…24V DC  
4…28V DC  
–28.8  
4V DC max.  
1V DC min.  
10% (2)  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
233  
Relay and Timer Specifications  
Load/Output Ratings  
(4)  
Cat. No.  
Rated Control Voltage  
Max. Load Voltage  
Range  
Continuous Load Current (Resistive) [A]  
(3)  
Max. Inrush Current  
Min.  
0.1  
Max.  
700-SFZY3Z25  
700-SFTY3Z24  
700-SFNY3Z25  
3
3
3
45 A @ 50/60 Hz,  
1 cycle  
100…240V AC  
4…48V DC  
75…264V AC  
3…52.8V DC  
0.1  
0.1  
18 A (10 ms)  
Characteristics  
Description  
Cat. No. 700-SFZY3Z25  
Cat. No. 700-SFTY3Z24  
Cat. No. 700-SFNY3Z25  
Load Switching Method/Device  
Triac  
Transistor  
1/2cycleofloadpowersource  
Pick-up Time  
1 ms max.  
0.5 ms max.  
cycle time (5) +1msmax.  
Drop-out Time  
Output ON Voltage Drop  
1/2 cycle of load power source cycle time (5) + 1 ms max.  
1.6V (RMS) max.  
2 ms max.  
1.5V max.  
5 mA max. (@ 100V AC);  
10 mA max. (@ 200V AC)  
600  
2.5 mA max. (@ 100V AC); 5 mA max. (@ 200V  
AC)  
600  
50  
250  
18  
Output Leakage Current  
5 mA max. (@ 50V DC)  
Output V , V (V)  
DRM CEO  
80  
Output di/dt (A/uS)  
Output dv/dt (V/uS)  
50  
250  
18  
2
2
Output I t (A S)  
Output Tj (°C) Max.  
125  
125  
150  
Insulation Resistance  
Dielectric Strength  
Vibration Resistance (Max.)  
Shock Resistance (Max.)  
100 MΩ min.(at500VDC)  
1,500V AC, 50/60 Hz for 1 min  
10…55 Hz, 1.5 mm double amplitude (10 G)  
2
1000 m/s (100 G)  
Ambient Temperature  
Operating: –30…+80 °C (–22…+176 °F) with no icing or condensation Storage: –30…+100 °C (–22…=212 °F) with no icing or condensation  
Ambient Humidity  
Standards Compliance  
Certifications  
45…85% (no condensation)  
UL 508, CSA C22.2 No. 14, EN/IEC 60947-1, -4-3, EN/IEC 60950  
cURus Recognized (File No. E96956, Guide NMFT2/NMFT8), CE Marked, VDE Certified  
Approx. 50 g  
Weight  
(1) With constant current input circuit system, SSR impedance varies with a change in input voltage.  
(2) Input impedance reaches its maximum at the operating voltage.  
(3) If the SSR operation is continuous ON/OFF, this value should be reduced by 50%. See the “Inrush Current Resistivity”graphs on page 116 for more details.  
(4) See “Load Current vs. Ambient Temperature Characteristicson page 116 for additional load current details.  
(5) 60 Hz full cycle time = 16.6 ms, 50 Hz full cycle time 20 ms.  
IMPORTANT This data is non-repetitive. Keep the inrush current to half the rated value if it occurs repetitively. Inrush current resistivity is  
the ability of an SSR to withstand a large surge current for a short period.  
Surges are considered non-repetitive (max. repeatability once every 2…5 seconds). Keep the inrush current to half the rated  
value if it occurs repetitively. Exceeding the non-repetitive inrush current will damage the SSR.  
234  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
(1)  
(1)  
Load Current vs. Ambient  
Inrush Current Resistivity  
700-SFZ… 700SFT…  
Inrush Current Resistivity  
700-SFN…  
Temperature Characteristics  
700-SF  
4
30  
28  
26  
50  
40  
24  
22  
3
2
20  
18  
16  
14  
12  
30  
20  
10  
8
6
4
2
1
10  
0
0
0
Ambient Temperature [° C]  
Energizing Time [ms]  
Energizing Time [ms]  
(1) Inrush current resistivity is defined as the ability of an SSR to withstand a large surge current for a short period. Surges are considered non-repetitive (max. repeatability once every 2…5 seconds).  
Keep the inrush current to half the rated value if it occurs repetitively. Exceeding the non-repetitive inrush current will damage the SSR.  
EMC Directive Compliance  
1. AC-switching models comply with EMC Directives under the  
following conditions  
3 m max.  
Load  
Input  
700-SF  
Output  
Varistor  
Film capacitor  
Varistor: 470 V, 0.6 W  
Film capacitor: 1  
µF, 250 VAC  
• Connect a varistor between the output terminals.  
• Connect a film capacitor to the load power supply.  
• The input cable must be less than 3 m.  
2. DC-switching models comply with EMC Directives under the  
following conditions  
Less than 10 m  
Load  
Input  
700-SF  
Output  
• The input cable must be less than 10 m.  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
235  
Relay and Timer Specifications  
Dimensions - 700-SF Relays  
All units in millimeters unless otherwise indicated. To convert millimeters to inches multiply by 0.0394. Dimensions are not intended to be used for  
manufacturing purposes.  
Terminal Arrangement/Input Connections  
(Bottom View)  
1
2
(+)  
(-)  
4(+)  
3
Load  
Load  
Input  
28  
max  
5
6(-)  
7
8
+
-
36.5 max  
42.5 max  
21.5  
max  
+
-
Input Voltage  
Notes: 1.The plus and minus symbols  
shown in parentheses are  
for DC loads.  
2.The coil has no polarity.  
IMPORTANT 700-SF is compatible with Cat. No. 700-HN116 socket.  
Basic Application Considerations of 700-SF  
High-density Mounting of Multiple Solid-state Relays (SSRs)  
If multiple SSRs are mounted side by side, the outer case wall of the SSR acts as a radiator. The SSR case serves to dissipate heat. Install the relays so  
that they are adequately ventilated. If poor ventilation is unavoidable, reduce the load current by half.  
Connection  
For DC load switching, the Bul. 700-SF SSR will operate properly if the load is connected to either the positive or negative load terminals.  
Protective Component to Extend SSR Life  
When controlling AC inductive loads, connect an inrush/surge absorbing device (varistor) across the SSR load terminals. If the SSR has built- in  
surge suppression (700-SE and 700-SH) and additional surge suppression is required, connect the varistor across the terminals of the load device.  
Select a varistor that meets the conditions of the load voltage that is outlined in the table.  
Load Voltage [V AC]  
100…120  
Varistor Voltage [V]  
240…270  
Varistor Surge Resistance  
200…240  
440…470  
1000 A min.  
380…480  
820…1000  
TIP For additional details on solid-state relays, see the Solid-State Relay Application Guide, publication 700-AT001.  
For a DC inductive load, a diode should be connected parallel to the load to absorb the counter electromotive  
force (OFF) of the load.  
Load  
Load power  
supply  
Input  
SSR  
236  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
700-SH Hockey Puck Relays  
100 A max. continuous load (output) current with appropriate heat sink  
264V AC, 530V AC, or 660V AC max. load voltage options  
3…32V DC, 4…32V DC, 80…130V AC, 200…260V AC, 20…280V AC/22…48V DC control (input) voltage options  
LED indicator for input/logic ON/OFF status monitoring  
Protective cover for added safety  
Input-to-  
Output  
Isolation  
Method  
Output (Load) Max.  
Continuous Current  
and Rated Voltage  
Range (1)  
Zero Cross  
Function  
Status  
Indicator  
Rated Input  
Control Voltage  
Photo  
Cat. No.(2)  
10 A @ 42…265V AC  
10 A @ 42…265V AC  
10 A @ 42…265V AC  
10 A @ 42…530V AC  
25 A @ 42…530V AC  
25 A @ 24…265V AC  
3…32V DC  
80…130V AC  
200…260V AC  
4…32V DC  
4…32V DC  
3…32V DC  
700-SH10JZ24  
700-SH10JA12  
700-SH10JA22  
700-SH10HZ25 (Series B)  
700-SH25HZ25 (Series B)  
700-SH25GZ24  
20…280V AC/  
22…48V DC  
25 A @ 24…265V AC  
50 A @ 24…265V AC  
50 A @ 24…265V AC  
700-SH25GA24  
700-SH50GZ24  
700-SH50GA24  
3…32V DC  
20…280V AC/  
22…48V DC  
50 A @ 42…530V AC  
25 A @ 42…660V AC  
4…32V DC  
4…32V DC  
700-SH50HZ25  
700-SH25VZ25  
20…280V AC/  
22…48V DC  
25 A @ 42…660V AC  
50 A @ 42…660V AC  
50 A @ 42…660V AC  
700-SH25VA24  
700-SH50VZ25  
700-SH50VA24  
Yes  
Yes  
4…32V DC  
Optocoupler  
20…280V AC/  
22…48V DC  
75 A @ 42…530V AC  
75 A @ 42…660V AC  
4…32V DC  
4…32V DC  
700-SH75HZ25  
700-SH75VZ25  
20…280V AC/  
22…48V DC  
75 A @ 42…530V AC  
700-SH75HA24  
20…280V AC/  
22…48V DC  
75 A @ 42…660V AC  
100 A @ 42…530V AC  
100 A @ 42…530V AC  
100 A @ 42…660V AC  
100 A @ 42…660V AC  
700-SH75VA24  
700-SH100HZ25  
700-SH100HA24  
700-SH100VZ25  
700-SH100VA24  
4…32V DC  
20…280V AC/  
22…48V DC  
4…32V DC  
20…280V AC/  
22…48V DC  
Yes  
Yes  
No  
5 A @ 3...60V DC  
3…32V DC  
700-SH5FZ24  
25 A @ 90…280V AC  
50 A @ 90…280V AC  
4…20 mA DC  
4…20 mA DC  
700-SH25WA25  
700-SH50WA25  
Yes  
(1) When used with heat sink.  
(2) All catalog numbers are Series A unless noted.  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
237  
Relay and Timer Specifications  
Accessories - 700-SH Relays  
Photo  
Description  
Pkg. Quantity  
Cat. No.  
Heat Sink— Panel or DIN Rail Mount  
1
700-SN10  
Heat Sink— Panel or DIN Rail Mount  
1
700-SN25  
Heat Sink— Panel or DIN Rail Mount  
1
1
700-SN50  
Heat Sink— Panel or DIN Rail Mount  
Heat Sink— Panel or DIN Rail Mount  
700-SN50HC  
1
700-SN50VHC  
DIN (#3) symmetrical hat rail  
35 x 7.5 x 1 m  
10  
199-DR1  
Thermal Conductive Pads  
50  
25  
10  
700-SHCPAD  
700-SHCOV  
700-SHTRMA  
Plastic Covers — for DC output version  
Thermal Adapters - for 100 A Wire  
238  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Specifications- 700-SH Relays  
Control/Input Ratings  
Cat. No.  
Operating Voltage  
Input Current @ Max.  
Voltage  
Voltage Level Pickup Voltage  
Drop-out Voltage  
3…32V DC  
80…130V AC  
12 mA  
13 mA  
13 mA  
12 mA  
20 mA  
12 mA  
20 mA  
12 mA  
20 mA  
4…20 mA  
12 mA  
2.75V DC max.  
70V AC max.  
190V AC max.  
4V DC max.  
18V AC/DC  
2.5V DC  
1.2V DC min.  
30V AC min. (1)  
90V AC min.  
1V DC min.  
6V AC/DC  
1.2V DC  
700-SH10J…  
200...280V AC  
4…32V DC  
700-SH_ _ H…  
700-SH_ _ G…  
700-SH_ _ V…  
20…280V AC/22…48V DC  
3…32V DC  
20…280V AC/22…48V DC  
4…32V DC  
-32V DC  
6V AC/DC  
1.2V DC  
3.5V DC  
20…280V AC/22…48V DC  
Current Control  
18V AC/DC  
6V AC/DC  
700-SH_ _ W…  
700-SH_ _ F…  
3…32V DC  
3V DC max.  
1.0V DC  
(1) When specified heatsink is used.  
Output Ratings  
(2)  
Cat. No.  
700-SH5FZ24  
Load Voltage Range  
3…60V DC  
Applicable Load Current with Heat Sink [A]  
0.001…5 A DC  
0.15…10  
0.15…10  
0.15…25  
0.15…25  
0.15…25  
0.15…25  
0.15…50  
0.15…50  
0.15…50  
0.15…50  
0.15…75  
0.15…75  
0.15…100  
0.15…100  
700-SH10J…  
42…265V AC  
42…530V AC  
24…265V AC  
42…530V AC  
42…660V AC  
90…280V AC  
24…265V AC  
42…530V AC  
42…660V AC  
90…280V AC  
42…530V AC  
42…660V AC  
42…530V AC  
42…660V AC  
700-SH10H…  
700-SH25G…  
700-SH25H…  
700-SH25V…  
700-SH25W…  
700-SH50G…  
700-SH50H…  
700-SH50V…  
700-SH50W…  
700-SH75H…  
700-SH75V…  
700-SH100H…  
700-SH100V…  
(2) AC unless indicated.  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
239  
Relay and Timer Specifications  
Characteristics  
Description  
Cat. Nos. 700-SH10, 25, 50  
(not including 700-SH_ _W)  
Cat. Nos. 700-SH75, 100  
Pick-up Time  
1/2 of load power source cycle time(DC input) / 1 of load power source cycle time (AC input)  
1/2 of load power source cycle time (DC input) / 2 of load power source cycle time (AC input)  
1.6V (RMS) max.  
Drop-out Time  
Output ON Voltage Drop  
<3 mA  
100MΩ min(@500VDC)  
RMS  
Output Leakage Current  
Insulation Resistance  
Dielectric Strength  
Vibration Resistance  
Shock Resistance  
100MΩ min.(at500VDC)  
>4000V AC  
RMS  
Malfunction: 10…55 Hz, 1.5 mm double amplitude  
2
Malfunction: 1000 m/s  
Operating: –20…+70 °C with no icing or condensation  
Storage: –40…+100 °C with no icing or condensation  
0…95% no condensing  
Ambient Temperature  
Ambient Humidity  
Standards Compliance  
Certifications  
UL 508, CSA C22.2 No. 14, EN/IEC 60947-1, -4-2, -4-3, EN 61000-6-2, EN 61000-6-4  
cURus Recognized (File No. E14843, Guide NPNT2), CSA Certified (File No. 240924)  
Weight  
Approx. 60 g  
Approx. 100 g  
Description  
Cat. No. 700-SH_ _W  
4.2 mA  
Pick-up Current  
Drop-out Current  
Voltage Drop  
4.1 mA  
<10V DC @ 20 mA  
<3 mA  
Leakage Current  
Insulation Voltage  
Vibration Resistance  
Shock Resistance  
Ambient Temperature  
Ambient Humidity  
<4000 V  
RMS  
Malfunction: 10…55 Hz, 1.5 mm double amplitude  
2
Malfunction: 1000 m/s  
Operating: –20…+70 °C with no icing or condensation  
0…95% no condensing  
UL 508, CSA C22.2 No. 14, EN/IEC 60947-1, -4-2, -4-3, EN 61000-6-2,  
EN 61000-6-4  
Standards Compliance  
Certifications  
Weight  
cURus Recognized (File No. E14843, Guide NPNT2), CSA Certified (File No. 24024)  
Approx. 60 g  
Description  
Cat. No. 700-SH5FZ24  
<3V DC  
Pick-up Voltage  
Drop-out Voltage  
>1V DC  
Activating Frequency  
Input Impedance  
<100 Hz  
1kΩ  
Response Time Pick-up @ Vin > 5V  
Response Time Drop-out  
<4000 uS  
<1 mS  
On-state Voltage Drop @ Rated Current  
<1.5V  
240  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Description  
Off-state Current Drop @ Rated Voltage  
Cat. No. 700-SH5FZ24  
<1 mA  
Insulation Voltage  
Vibration Resistance  
Shock Resistance  
<1 mA  
Malfunction: 10…55 Hz, 1.5 mm double amplitude  
2
Malfunction: 1,000 m/s  
Ambient Temperature  
Ambient Humidity  
Standards Compliance  
Operating: –20…+70 °C with no icing or condensation  
0…95% no condensing  
UL 508, CSA C22.2 No. 14, EN/IEC 60947-1, -4-2, -4-3, EN 61000-6-2, EN61000-6-4  
cURus Recognized (File No. E14843, Guide NPNT2), CSA Certified (File No.  
240924)  
Certifications  
Weight  
Approx. 60 g  
Surge Current vs. Ambient Temperature Characteristics  
Surge current resistivity for 700-SH50....  
700A  
Surge current resistivity for 700-SH10, 25....  
350A  
600A  
500A  
400A  
300A  
200A  
100A  
0A  
300A  
250A  
200A  
150A  
100A  
50A  
0A  
10ms  
100ms  
1000ms  
10000m s  
Energizing time (ms)  
10ms  
100ms  
1000ms  
10000m s  
Energizing time (ms)  
Surge current resistivity for 700-SH75....  
Surge current resistivity for 700SH100....  
1200A  
2000A  
1800A  
1600A  
1400A  
1200A  
1000A  
800A  
600A  
400A  
200A  
0A  
1000A  
800A  
600A  
400A  
200A  
0A  
10ms  
100ms  
1000ms  
10000m s  
Energizing time (ms)  
10ms  
100ms  
1000ms  
10000m s  
Energizing time (ms)  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
241  
Relay and Timer Specifications  
Load current vs. ambient temperature characteristics for 700-SH10….  
Load current vs. ambient temperature characteristics for 700-SH25….  
30  
25  
20  
15  
10  
5
12  
10  
8
700-SN50VHC  
700-SN50HC  
700-SN50(V)HC  
700-SN10 700-SN25  
700-SN10  
700-SN25  
700-SN50  
700-SN50  
6
4
No heatsink  
No heatsink  
2
0
0
-20  
-10  
0
10  
20  
30  
40  
50  
60  
70  
80  
-20  
-10  
0
10  
20  
30  
40  
50  
60  
70  
80  
Ambient temperature (ºC)  
Ambient temperature (ºC)  
Load current vs. ambient temperature characteristics for 700-SH75….  
Load current vs. ambient temperature characteristics for 700-SH50….  
80  
70  
60  
50  
40  
30  
20  
10  
0
60  
50  
40  
30  
20  
10  
0
700-SN50VHC  
700-SN50HC  
700-SN50VHC  
700-SN50HC  
700-SN10  
700-SN25  
700-SN50  
700-  
700-SN25  
700-SN50  
No heatsink  
No heatsink  
-20  
-10  
0
10  
20  
30  
40  
50  
60  
70  
80  
-20  
-10  
0
10  
20  
30  
40  
50  
60  
70  
80  
Ambient temperature (ºC)  
Ambient temperature (ºC)  
Load current vs. ambient temperature characteristics for 700-SH5…..  
Load current vs. ambient temperature characteristics for 700-SH100….  
6
5
4
3
2
1
0
120  
100  
80  
60  
40  
20  
0
700-SN50(V) HC  
700-SN50  
700-SN50  
700-SN50HC  
700-SN50VHC  
700-SN10  
700-SN25  
No heatsink  
700-SN10  
700-SN25  
No heatsink  
-10  
-20  
-10  
0
10  
20  
30  
40  
50  
60  
70  
80  
-20  
0
10  
20  
30  
40  
50  
60  
70  
80  
Ambient temperature (ºC)  
Ambient temperature (ºC)  
242  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
(1) (2) (3) (4)  
Mounting Considerations  
All units are in millimeters unless otherwise indicated. To convert to inches multiply by 0.0394. Dimensions are not intended for manufacturing  
purposes.  
45.5  
Terminal Arrangement/  
Internal Connections  
(Top View)  
Mounting Holes  
(Bottom View)  
5.3  
Load  
2 x M5  
Screws  
Load  
Power  
Supply  
Load  
Two Ø 4.4  
or M4 Holes  
T1  
L1  
47.5  
A1  
A2  
Input  
2 x M3  
Screws  
13.0  
25  
45.5  
Cat. No. 700-SH5F…  
44.8  
Two Ø 4.4  
or M4 Holes  
12.3  
2 X M5  
Screws  
Operating  
Indicator  
APPLY  
47.5  
HEATSINK  
COMPOUND  
2 X M3  
Screws  
5.2  
5.25  
25  
45.5  
Cat. No. 700-SH10, -SH25, -SH50, -SH75, -SH100  
(1) The proper mounting orientation of the heat sink is so the heat fins run perpendicular to the floor (vertical) to maximize ventilation flow. If the fins do not run perpendicular to the floor, a 30% current derating is required.  
(2) When attaching a heat sink to 700-SH, apply a thin layer of heat conductive grease (approximately 0.002 in. thick) on the heat sink to maximize heat transfer between the SSR and the heat sink.  
Recommended types: Silicon based, Dow Corning 340, Toshiba YG6240; Non-silicon based, AOS company type 53300 (Cat. No. 46801-010-01).  
(3) Tighten the SSR panel/heat sink mounting screws to a torque of 0.78…0.98 N•m (6.9…8.7 lb•in).  
(4) Tighten the SSR terminal wiring screws as follows M4: 0.98…1.37 N•m (8.67…12.12 lb•in), M5: 1.57…2.35 N•m (13.89…20.8 lb•in).  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
243  
Relay and Timer Specifications  
7±±-SN1±  
7±±-SN25  
7±±-SN5±  
7±±-SN5±HC  
7±±-SN5±VHC  
12  
67  
27,5  
28,5  
Cat. No.700-SHTRMA  
Cat. No. 700-SHCOV  
244  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Load Connection  
For an AC load, use a power supply that is rated at 50 Hz. or 60 Hz. The maximum operating frequency is 10 Hz.  
The 700-SH has a built-in varistor for surge/inrush protection of AC loads. If additional suppression is required, connect an external  
varistor across the load device terminals. Select a varistor, which meets the load voltage condition that is outlined in the table.  
Load Voltage [V AC]  
100…120  
Varistor Voltage [V]  
240…270  
Varistor Surge Resistance  
200…240  
440…470  
1000 A min.  
380…480  
820…1000  
TIP For additional details on solid-state relays, see the Solid-State Relay Application Guide, publication 700-AT001.  
Zero Cross Function  
An SSR with a zero cross function operates when an AC load voltage reaches the zero point or its vicinity. This reduces clicking noises  
when the load is switched and minimizes the influence of an inductive load, (such as, lamp, heater, or motor) on the power supply because  
the inrush current of the load is reduced. This can also minimize the scale of the inrush current protection circuit.  
Output (load voltage)  
ON  
Input  
OFF  
At a low applied voltage (for example, 24V AC) the load current is not fully supplied. When the unit is switched ON, the voltage  
required to power the unit deprives the output signal of the necessary voltage level and thus creates loss time. The lower the load voltage  
is, the greater the loss time is. This condition, however, will not create any serious problems.  
Loss time  
For a DC inductive load, a diode should be connected parallel to the load to absorb the counter electromotive force (OFF) of the load.  
Load  
Load power  
supply  
Input  
SSR  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
245  
Relay and Timer Specifications  
700-SK Slim Line Relays  
High-response speed models  
Input sensor module to allow high voltage 100…240V AC or 12…24V DC sensor  
Interface to low voltage (logic) device such as a PC output module for typical SSR applications  
LED indicator  
Input modules and output modules can be used with the 700-HN121 or 700-HN221 sockets  
Input/Sensor Module  
Logic Level  
Input-to-Output Isolation  
Method  
Rated Input Sensor  
Voltage  
Status Indicator  
Response Frequency  
Cat. No.  
Supply Voltage Supply Current  
10 Hz  
1 kHz  
100…240V AC (1)  
12…24V DC  
700-SKICA18  
700-SKICZ24  
Photocoupler  
Yes  
4…32V DC  
0.1…100 mA  
(1) 47…63 Hz  
Output/SSR Module  
Input-to-Output Isolation Zero Cross  
Output (Load) Max. Continuous Current Rated Input Control  
Status Indicator  
Cat. No.  
Method  
Function  
and Rated Voltage Range  
Voltage  
Yes  
700-SKOZ2Z25  
700-SKON2Z25  
700-SKOC2Z25  
700-SKOC1Z25  
(1)  
Phototriac  
2 A @ 100…240V AC  
No  
Yes  
5…24V DC  
2 A @ 5…48V DC  
Photocoupler  
Not Applicable  
1.5 A @ 48…200V DC  
(1) 47…63 Hz  
Accessories - 700-SK Relays  
Photo  
Description  
Pcs./Pkg.  
Cat. No.  
Screw Terminal Socket — Panel or DIN Rail Mounting 5-blade miniature socket with 10 A rating for use with 1-  
pole, 700-HK relays. Accepts forked lug conductors. Socket includes a retainer clip.  
10  
700-HN121  
DIN (#3) symmetrical hat rail  
35 x 7.5 x 1 m  
10  
199-DR1  
Pre-Printed Identification Tags — contains 10 sheets of pre-printed and blank tags. Each sheet contains 13 sets of  
the markings CR…9CR, TR…9TR, M…9M, F, R, 1S, and 117 blank tags. Tags are peel-off with sticky backing for easy  
placement on relays.  
10  
10  
700-N40  
700-N41  
Blank Identification Tags — contains 10 sheets of blank identification tags for customer specialized printing. Each  
sheet contains 546 blank tags. Tags are peel-off with sticky backing for easy placement on relays.  
246  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
Specifications - 700-SK Relays  
Input Sensor Module  
Input Sensor Ratings  
Cat. No.  
Rated Input Voltage  
Max. Operating Input  
Voltage Range  
Input Current  
Pick-up Voltage  
Drop-out Voltage  
700-SKICZ24  
12…24V DC  
6.6…32V DC  
60…264V AC  
8 mA max.  
6.6V DC max.  
60V AC max.  
3.6V DC min.  
20V AC min.  
700-SKICA18  
100…240V AC  
15 mA max.  
Output Logic Ratings  
Cat. No.  
Logic Level Supply Voltage  
Logic Level Supply Current Draw  
700-SKICZ24  
700-SKICA18  
4…32V DC  
0.1…100 mA  
Characteristics  
Description  
Cat. No. 700-SKICA18  
20 ms max.  
Cat. No. 700-SKICZ24  
0.1 ms max.  
Pick-up time  
Drop-out time  
Response frequency  
20 ms max.  
0.1 ms max.  
10 Hz  
100 Hz  
Output ON voltage drop  
1.6V max.  
Leakage current (from SSR)  
5 μA max.  
Output V , V (V)  
DRM CEO  
80 (ref. value)  
80 (ref. value)  
Output di/dt (A/uS)  
Output dv/dt (V/uS)  
150  
150  
2
2
Output I t (A S)  
Output Tj (°C) Max.  
Insulation Resistance  
Dielectric Strength  
100 MΩ min. between input and output  
4000V AC, 50/60 Hz for 1 min between input and output  
10…55 Hz, 1.5 mm double amplitude (10 G)  
1000 m/s2 (100 G)  
Vibration Resistance (Max.)  
Shock Resistance (Max.)  
Operating  
–30…+80 °C (–22…+176 °F) with no icing or condensation  
–30…+100 °C (–22…+212 °F) with no icing or condensation  
UL 508, CSA C22.2 No. 14, EN/IEC 60950  
Ambient Temperature  
Storage  
Standards Compliance  
Certifications  
cURus Recognized (File No. E96956, Guide NMFT2/NMFT8), CE Marked, TÜV Certified  
45…85% (no condensation)  
Ambient humidity Operating  
Weight  
Approx. 18 g  
Output SSR Module  
Control/Input Ratings  
Cat. No.  
(1)  
Rated Control  
Voltage  
Max. Operating  
Control Voltage  
Range  
Max. Reverse  
Control Voltage  
Impedance  
Pick-up Voltage  
Drop-out Voltage  
700-SKOZ2Z25  
700-SKON2Z25  
700-SKOC2Z25  
700-SKOC1Z25  
15 mA max.  
at 25 °C (77 °F)  
5…24V DC  
4…32V DC  
-32V DC  
4V DC max.  
1V DC min.  
8 mA max.  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
247  
Relay and Timer Specifications  
Load/Output Ratings  
Cat. No.  
(3)  
Rated Load Voltage  
Maximum Load Voltage  
Range  
Continuous Load Current (Resistive) [A]  
(2)  
Max. Inrush Current  
Min.  
Max.  
700-SKOZ2Z25  
700-SKON2Z25  
700-SKOC2Z25  
700-SKOC1Z25  
30 A (@50/60 Hz,  
One cycle)  
100…240V AC  
75…264V AC  
0.05  
2
5…48V DC  
4…60V DC  
0.1  
0.1  
2
8 A (10 ms)  
8 A (10 ms)  
48…200V DC  
40…200V DC  
1.5  
(1) With a constant current input system. SSR impedance varies with a change in input voltage.  
(2) See "Load Current vs. Ambient Temperature Characteristics" graphs on page 126 for additional details.  
(3) If the SSR operation is continuous ON/OFF, this value should be reduced by 50%. See the “Inrush Current Resistivity”graphs on page 126 for more details.  
Characteristics  
Description  
Load Switching Method/Device  
Pick-up Time  
Cat. No. 700-SKOZ2Z25  
Cat. No. 700-SKON2Z25  
Cat. No. 700-SKOC2Z25  
Cat. No. 700-SKOC1Z25  
Triac  
Transistor  
1/2 cycle of load power source cycle time (1) + 1 ms max.  
1 ms max.  
2 ms max.  
100 Hz  
Drop-out Time  
1/2 of load power source cycle time (1) + 1 ms max.  
Response Frequency  
20 Hz  
Output ON Voltage Drop  
Leakage Current (from SSR)  
1.6V max.  
1.5 mA max.  
2.5V max.  
1 mA max.  
Output V , V (V)  
DRM CEO  
600 (ref.value)  
600 (ref.value)  
80 (ref.value)  
400 (ref.value)  
Output di/dt (A/uS)  
Output dv/dt (V/uS)  
30  
30  
150  
150  
300  
10.4  
125  
300  
10.4  
125  
2
2
Output I t (A S)  
Output Tj (°C) Max.  
Insulation Resistance  
Dielectric Strength  
100 MΩ min. between input and output  
4000V AC, 50/60 Hz for 1 min between input and output  
10…55 Hz, 1.5 mm double amplitude (10 G)  
Vibration Resistance (Max.)  
Shock Resistance (Max.)  
2
1000 m/s (100 G)  
Operating  
Storage  
–30…+80 °C (–22…+176 °F) with no icing or condensation  
–30…+100 °C (–22…+212 °F) with no icing or condensation  
UL 508, CSA C22.2 No. 14, EN/IEC 60950  
Ambient  
Temperature  
Standards Compliance  
Certifications  
cURus Recognized (File No. E96956, Guide NMFT2/NMFT8), CE Marked, TÜV Certified  
Ambient Humidity Operating  
Weight  
45…85% (no condensation)  
Approx. 18 g  
(1) 60 Hz cycle time = 16.6 ms, 50 Hz cycle time = 20 ms.  
Load Current vs. Ambient Temperature Characteristics  
For 2 A Versions  
2
2
1.5  
1
1.5  
1
0.5  
0.5  
Ambient Temperature [° C]  
Ambient Temperature [° C]  
248  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Relay and Timer Specifications  
(2)  
Inrush Current Resistivity  
7±±-SKOC2  
7±±-SKOZ/SKOC1  
7±±-SKOZ/SKON  
10  
9
8
7
6
5
4
3
2
1
0
10  
9
30  
8
7
6
5
4
3
2
20  
10  
1
0
Energizing Time (ms)  
Energizing Time (ms)  
Energizing Time (ms)  
(2) Inrush current resistivity is the ability of an SSR to withstand a large surge current for a short period. Surges are considered non-repetitive (max. repeatability once every 2…5 seconds). Keep the inrush current to half the rated  
value if it occurs repetitively. Exceeding the non-repetitive inrush current will damage the SSR.  
Dimensions - 700-SK Relays  
All units are in millimeters unless otherwise indicated. To convert to inches multiply by 0.0394. Dimensions are not to be used for manufacturing  
purposes.  
IMPORTANT The input module (700-SKI) and output module (700-SKO) are compatible with the Cat. No. 700-HN121 socket.  
Terminal Arrangement/  
Internal Connections  
1
5.2  
(Bottom View)  
3
4
9.6  
3
(+)  
(–)  
0.5  
29 max.  
17.4  
4
4.75  
Load  
1
5
13 max.  
28 max.  
5
7.5  
4.7  
0.5  
Input  
4.75  
4
5
1
10  
(–)  
(+)  
2
20  
Application Considerations of the700-SK Relay  
Connection  
For DC load switching, 700-SK SSR will operate properly if the load is connected to either the positive or negative SSR load terminal. The load can  
be connected to either positive or negative output terminals of the SSR.  
Protective Element (to extend SSR life)  
Since the SSR does not incorporate a surge absorption component, be sure to connect a surge absorption component when using the SSR to control  
an inductive load.  
TIP For additional details on solid-state relays, see the Solid-State Relay Application Guide, publication 700-AT001.  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
249  
Relay and Timer Specifications  
Additional Resources  
These documents contain additional information concerning related products from Rockwell Automation.  
Resource  
Description  
General Purpose, Interposing, Solid-State and Specialty Relays Brochure publication  
700-BR018  
Provides product overview and applications for Bul 700 relay line.  
Solid-state Relay Application Guide, publication 700-AT001  
Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1  
Product Certifications website, rok.auto/certifications.  
Provides methods for applying and troubleshooting Solid-state relays.  
Provides general guidelines for installing a Rockwell Automation industrial system.  
Provides declarations of conformity, certificates, and other certification details.  
You can view or download publications at http://www.rockwellautomation.com/global/literature-library/  
overview.page.  
250  
Rockwell Automation Publication 700-TD552D-EN-P - June 2019  
Rockwell Automation Support  
Use the following resources to access support information.  
Knowledgebase Articles, How-to Videos, FAQs, Chat,  
User Forums, and Product Notification Updates.  
Technical Support Center  
www.rockwellautomation.com/knowledgebase  
www.rockwellautomation.com/global/support/get-support-  
now.page  
Local Technical Support Phone Numbers  
Locate the phone number for your country.  
Find the Direct Dial Code for your product. Use the  
code to route your call directly to a technical support  
engineer.  
www.rockwellautomation.com/global/support/direct-  
dial.page  
Direct Dial Codes  
Literature Library  
Installation Instructions, Manuals, Brochures, and  
Technical Data.  
www.rockwellautomation.com/literature  
Get help determining how products interact, check  
features and capabilities, and find associated  
firmware.  
Product Compatibility and Download Center  
(PCDC)  
www.rockwellautomation.com/global/support/pcdc.page  
Documentation Feedback  
Your comments will help us serve your documentation needs better. If you have any suggestions on how to improve this document, complete the  
How Are We Doing? form at http://literature.rockwellautomation.com/idc/groups/literature/documents/du/ra-du002_-en-e.pdf.  
Rockwell Automation maintains current product environmental information on its website at http://www.rockwellautomation.com/rockwellautomation/about-us/sustainability-ethics/product-environmental-compliance.page.  
Allen-Bradley, Rockwell Automation, and Rockwell Software are trademarks of Rockwell Automation, Inc.  
Trademarks not belonging to Rockwell Automation are property of their respective companies.  
Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400  
Publication 700-TD552D-EN-P - June 2019  
Supersedes Publication 700-TD552C-EN-P - October 2018  
Copyright © 2019 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.  

相关型号:

700-HA

General Purpose Relays
ALLEN-BRADLEY

700-HA32A06

General Purpose Relays
ALLEN-BRADLEY

700-HA32A1

General Purpose Relays
ALLEN-BRADLEY

700-HA32A12

General Purpose Relays
ALLEN-BRADLEY

700-HA32A2

General Purpose Relays
ALLEN-BRADLEY

700-HA32A24

General Purpose Relays
ALLEN-BRADLEY

700-HA32A27

General Purpose Relays
ALLEN-BRADLEY

700-HA32Z06

General Purpose Relays
ALLEN-BRADLEY

700-HA32Z1

General Purpose Relays
ALLEN-BRADLEY

700-HA32Z12

General Purpose Relays
ALLEN-BRADLEY

700-HA32Z2

General Purpose Relays
ALLEN-BRADLEY

700-HA32Z24

General Purpose Relays
ALLEN-BRADLEY