100VAC Input/24VDC (200mA) Output  
Non-Isolated AC/DC Converter  
BP5039A  
Absolute Maximum Ratings  
Dimensions (Unit : mm)  
Parameter  
Input voltage  
Symbol  
Vcc  
Limits  
170  
Unit  
V
35.0MAX.  
9.1MAX.  
Maximum output current  
ESD endurance  
IoMAX  
Vsurge  
TcMAX  
Topr  
200  
mApk  
kV  
2
1
3
5
7
10  
12  
Maximum surface temperature  
Operating Temperature range  
Storage temperature range  
105  
°C  
°C  
°C  
0.25±0.05  
7.62  
1.3±0.2  
2.5411=27.94  
20 to +80  
25 to +105  
0.5±0.1  
4.85MAX.  
5.08  
3.6MAX.  
Tstg  
4.25MAX.  
Electrical Characteristics  
Derating Curve  
Parameter  
Input voltage range  
Output voltage  
Output current  
Line regulation  
Load regulation  
Output ripple voltage  
Power conversion efficiency  
Output current at  
Symbol Min.  
Typ.  
Max.  
170  
26  
200  
0.50  
0.50  
Conditions  
DC (80 to 120VAC)  
Vi=141V, Io=100mA  
Vi=141V  
Vi=113 to 170V, Io=100mA  
Vi=141V, Io=0 to 100mA  
Vi=141V, Io=100mA  
Vi=141V, Io=200mA  
Vi=170V, Output short, Ta=25°C  
Vi=170V, Output short, Ta=80°C  
Unit  
V
V
mA  
V
V
Vp-p  
%
mA  
mA  
Derating Curve  
113  
22  
0
Vi  
Vo  
Io  
141  
24  
0.30  
0.25  
0.07  
82  
250  
200  
150  
1  
Operation Range  
100  
0.50  
0.50  
Vr  
Vl  
Vp  
η
50  
2  
0
-30-20-10  
0 10 20 30 40 50 60 70 80 90  
Ambient Temperature Ta(°C)  
70  
2  
200  
Io1  
245  
220  
Conversion Efficiency  
overcurrent  
150  
Io2  
Conversion Efficiency  
1 Maximum output current varies depending on ambient temperature ; please refer to derating curve.  
2 Please refer to Load regulation, Conversion efficiency.  
(Ta=31°C, Vi=141V)  
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
Application Circuit  
Pin No.  
Function  
Output terminal Vo(24V)  
Not used  
BP5039A  
1
2
Be sure to use fuse for safety.  
0
50  
100  
150  
200  
3
Choke coil connect  
Not used  
Output Current Io(mA)  
4
5
Choke coil connect  
Not used  
12 10  
7 5 3 1  
6
Load Regulation  
7
COMMON  
DC motor  
8
Not used  
FUSE  
Load Regulation  
Not used  
R1  
9
Ii  
Io  
C2  
D1  
(Ta=25°C, Vi=141V)  
30  
10  
11  
12  
N.C.  
L1  
+
+
Not used  
25  
20  
15  
10  
5
C3  
C1  
Vo  
Vi  
Input terminal Vi(141VDC)  
ZNR  
Please verify operation and characteristics in the customer's circuit before actual usage.  
Ensure that the load current does not exceed the maximum rating.  
0
0
50  
100 150 200 250 300  
Output Current Io(mA)  
External Component Specifications  
FUSE: FUSE  
Use a quick-acting fuse of (1A)  
Surface Temperature Increase  
C1: Input capacitor  
above 250V, 22 to 820µF  
Ripple current 0.13Arms or above  
Surface Temperature Increase  
(Ta=315°C, Vi=141V)  
40  
35  
30  
25  
20  
15  
10  
5
C2: Output capacitor  
above 25V, 100 to 470µF low impedance  
ESR : 0.4Max.  
Ripple current 0.25Arms or above  
Capacitor impedance affects the output ripple voltage.  
C3: Noise reduction  
capacitor  
above 250V, 0.1 to 0.22µF  
Use a film or ceramic capacitor  
Evaluate under actual operating conditions.  
0
0
50  
100  
150  
200  
250  
Output Current Io(mA)  
L1: Power Inductor  
D1: Rectifier diode  
Inductance : 1.5mH Rating current : above 0.4A  
In the absolute maximum ratings, the reverse surge voltage should be  
400V or above the average rectifier current should be 1A or greater,  
and the forward surge current should be 20A or more.  
10 to 221/4W  
R1: Noise reduction resistor  
ZNR: Varistor  
Determine the ideal value through actual testing.  
A varistor must be used to protect against lightning surges and  
static electricity.  
www.rohm.com  
©2010 ROHM Co., Ltd. All rights reserved.  
2010.01 - Rev.A  
1/1  
Notice  
N o t e s  
No copying or reproduction of this document, in part or in whole, is permitted without the  
consent of ROHM Co.,Ltd.  
The content specified herein is subject to change for improvement without notice.  
The content specified herein is for the purpose of introducing ROHM's products (hereinafter  
"Products"). If you wish to use any such Product, please be sure to refer to the specifications,  
which can be obtained from ROHM upon request.  
Examples of application circuits, circuit constants and any other information contained herein  
illustrate the standard usage and operations of the Products. The peripheral conditions must  
be taken into account when designing circuits for mass production.  
Great care was taken in ensuring the accuracy of the information specified in this document.  
However, should you incur any damage arising from any inaccuracy or misprint of such  
information, ROHM shall bear no responsibility for such damage.  
The technical information specified herein is intended only to show the typical functions of and  
examples of application circuits for the Products. ROHM does not grant you, explicitly or  
implicitly, any license to use or exercise intellectual property or other rights held by ROHM and  
other parties. ROHM shall bear no responsibility whatsoever for any dispute arising from the  
use of such technical information.  
The Products specified in this document are intended to be used with general-use electronic  
equipment or devices (such as audio visual equipment, office-automation equipment, commu-  
nication devices, electronic appliances and amusement devices).  
The Products specified in this document are not designed to be radiation tolerant.  
While ROHM always makes efforts to enhance the quality and reliability of its Products, a  
Product may fail or malfunction for a variety of reasons.  
Please be sure to implement in your equipment using the Products safety measures to guard  
against the possibility of physical injury, fire or any other damage caused in the event of the  
failure of any Product, such as derating, redundancy, fire control and fail-safe designs. ROHM  
shall bear no responsibility whatsoever for your use of any Product outside of the prescribed  
scope or not in accordance with the instruction manual.  
The Products are not designed or manufactured to be used with any equipment, device or  
system which requires an extremely high level of reliability the failure or malfunction of which  
may result in a direct threat to human life or create a risk of human injury (such as a medical  
instrument, transportation equipment, aerospace machinery, nuclear-reactor controller, fuel-  
controller or other safety device). ROHM shall bear no responsibility in any way for use of any  
of the Products for the above special purposes. If a Product is intended to be used for any  
such special purpose, please contact a ROHM sales representative before purchasing.  
If you intend to export or ship overseas any Product or technology specified herein that may  
be controlled under the Foreign Exchange and the Foreign Trade Law, you will be required to  
obtain a license or permit under the Law.  
Thank you for your accessing to ROHM product informations.  
More detail product informations and catalogs are available, please contact us.  
ROHM Customer Support System  
http://www.rohm.com/contact/  
www.rohm.com  
© 2010 ROHM Co., Ltd. All rights reserved.  
R1010  
A

相关型号:

BP5039B12

AC100V input, 12V/300mA output
ROHM

BP5039B12_10

Non-Isolated AC/DC Converter
ROHM

BP5040

AC / DC converter unit
ROHM

BP5041

AC / DC converter unit
ROHM

BP5041A

AC220V input, 12V/100mA output
ROHM

BP5041A15

AC/DC converter AC220V input, 15V/80mA output
ROHM

BP5041A5

AC220V input, 5V/100mA output
ROHM

BP5041A5_10

Non-Isolated AC/DC Converter
ROHM

BP5041A_10

Non-Isolated AC/DC Converter
ROHM

BP5041B15

AC220V input, 15V/80mA output
ROHM

BP5041B15_10

Non-Isolated AC/DC Converter
ROHM

BP5042-15

AC/DC CONVERTER
ROHM