RPM7157-H8R [ROHM]

IR Receiver Module; 红外接收器模块
RPM7157-H8R
型号: RPM7157-H8R
厂家: ROHM    ROHM
描述:

IR Receiver Module
红外接收器模块

光电 光电集成电路 远程控制 输出元件
文件: 总8页 (文件大小:152K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
RPM7157-R series  
Photo Link Module  
IR Receiver Module  
RPM7157-R series  
RPM7157-R series are remote control receiver modules. Small-sized, light-weight, and low current consumption  
modules have been achieved by using resin mold.  
zCenter frequency  
56.9kHz  
zApplications  
All household electric appliances such as TV, DVD, air conditioner and audio equipment.  
zFeatures  
1) Low current consumption. (1.0mATyp.)  
2) High ripple rejection.  
3) 5 types of holders available for each set.  
zRPM7157-R series  
with holders  
Straight type  
RSIP-A3  
L forming  
RSIP-A3 V4  
SIDE VIEW  
SIDE VIEW  
TOP VIEW  
TOP VIEW  
TOP VIEW  
RSIP-A3 (H13)  
RSIP-A3 (H5)  
RSIP-A3 (H4)  
RSIP-A3 (H8)  
RSIP-A3 (H9)  
Height to lens  
Products No.  
5.5mm  
4.8mm  
15.0mm  
9.6mm  
15.9mm  
7.2mm  
12.0mm  
RPM7157-R  
RPM7157-V4R  
RPM7157-H13R  
RPM7157-H5R  
RPM7157-H4R  
RPM7157-H8R  
RPM7157-H9R  
Under development  
zAbsolute maximum ratings (Ta = 25°C)  
Parameter  
Supply Voltage  
Symbol  
Limits  
Unit  
V
CC  
0.3 to +7.0  
2.0  
V
mA  
˚C  
Output Current  
lo  
Storage temperature  
Operating temperature  
Tstg  
Topr  
30 to +100  
10 to +75  
˚C  
zRecommended operating conditions (Ta = 25°C)  
Parameter  
Symbol  
Min.  
4.5  
Typ.  
5.0  
Max.  
5.5  
Unit  
V
VCC  
Supply Voltage  
Rev.A  
1/7  
RPM7157-R series  
Photo Link Module  
zBlock diagram  
VCC  
22k  
AMP  
LIMITER  
Comparator  
ROUT  
I / V  
BPF  
Detector  
zTerminal description  
Pin No.  
Pin name  
Function  
1
2
3
R
OUT  
OUTPUT TERMINAL  
GND  
GROUND  
V
CC  
POWER SUPPLY  
zElectrical characteristics (Unless otherwise noted, Ta = 25°C VCC=5V)  
Parameter  
Symbol  
Min.  
Typ.  
1.0  
15  
Max.  
1.6  
Unit  
mA  
m
Conditions  
Consumption Current  
Effective Distance  
I
CC  
No outside light, No signal input  
Outer light condition Ee < 10 (Ix) 1  
1  
L
8
4.5  
V
High Level Output Voltage  
Low Level Output Voltage  
V
H
0.5  
V
VL  
Isink=200µA  
1  
400  
400  
Outer light condition Ee < 10 (Ix) 1  
Outer light condition Ee < 10 (Ix) 1  
ON Pulse Width  
OFF Pulse Width  
Center frequency  
T
ON  
600  
600  
800  
800  
µs  
µs  
T
OFF  
kHz  
fo  
56.9  
45  
2  
2  
deg  
deg  
Horizontal half angle  
Vertical half angle  
θ 1/2  
θ 1/2  
35  
1 600/600µs burst wave is transmitted by standard transmitter. However, it must be measured after the initial transmission pulse is 100 pulse.  
2 It is an angle when the linear arrival distance become half.  
z Measurement Conditions  
(1) Transmit signal  
600µs  
600µs  
Carrier frequency=fo, Duty=50%  
Fig.1 Transmit signal  
Rev.A  
2/7  
RPM7157-R series  
Photo Link Module  
(2) Standard transmitter  
λ peak=940nm  
λ ∆=40nm  
Io=VOUT / R  
20cm  
RPM-302B  
Standard transmitter  
R
V
OUT  
Fig.2 Measurement of standard transmitter proofreading  
When standard transmitter output the signal at Fig.1 standard photodiode output become Io=5µAp-p under the  
measurement condition Fig.2.  
(The radiant intensity of standard transmitter : 50mW / sr)  
RPM-302B : standard photodiode has short current Isc=27µA at E=1000(lx)  
(using CIE standard light source A)  
(3) Measurement effective distance, horizontal & vertical half angle  
RPM7157-R series  
θ
θ
Standard transmitter  
Light detector face  
illuminance : Ee  
Effective distance : L  
(θ ; Indicates horizontal and vertical directions)  
Fig.3 Measurement condition for effective distance  
Effective distance L  
: Effective distance at θ=0° Fig.3  
Horizontal & vertical half angle θ : The angle which effective distance became 50% of L.  
Rev.A  
3/7  
RPM7157-R series  
Photo Link Module  
(4) Output signal  
600µs  
600µs  
Transmit signal  
Output signal  
Carrier frequency=f  
Carrier Duty=50%  
0
V
V
CC  
H
1/2 VCC  
V
L
GND  
T
ON  
TOFF  
Fig.4  
(5) Measurement circuit for the output voltage and the consumption current  
I
CC  
V
CC  
A
ROUT  
V
CC  
RPM7157-R  
V
V
H,  
V
L
GND  
Fig.5  
Rev.A  
4/7  
RPM7157-R series  
Photo Link Module  
zHow to use the receiver without holder  
Please use the receiver with shield case or shield plate as an EMI noise measures.  
(Shield case and shield plate are required to be grounded.)  
Because internal or external noise (CRT, fluorescent tube, motor, LCD backlight) of the receiver may cause malfunction  
like a reduced effective distance.  
(In the case of internal and external noise are strong, please use RPM7157-HxR series with holder.)  
zNotes  
(1) All characteristics of the receiver in this specification are specified by supplying burst wave form with ROHM standard  
transmitter (Shown as 8 (2) ).  
If in case of other burst wave form will be used, please check these spec. Carefully under the evaluations.  
(2) When the receiver will be used as the wire-less remote controller, please use the signal method the signal format  
which refer to “Measures to prevent malfunctioning of IR remote-controlled electric home appliances”. (Published July  
1987 by Association of Electric Home Appliances)  
If using other signal method, signal format, (ex: signal format which not including the leader signal) the receiver might  
have chances to miss-function.  
(3) Please set up transmitter’s carrier frequency as same as the receiver’s f0 frequency. Otherwise error might be  
occurred.  
(4) If transmission signal has non-continues carrier, error might be occurred. Continuous carrier is necessary.  
T1T2  
T1  
T2  
(5) The receiver was designed to use as in-door use only.  
Therefore, please understand that the receiver cannot cover all characteristics, in case of using it out-door.  
(6) Noise environment (Light noise from inverter Lamp, and other kind of Lamps, Power ripple, electromagnetic noise from  
power circuit, and etc) may cause a reduced effective distance.  
(7) Emitting unit (remote control transmitter) has to be considered about its emitting device function, characteristics and  
characteristics of the receiver.  
(8) Please connect “Holder” on to the “Ground (GND)” of PCB.  
If the holder is not connected to the GND, there is a possibility of worsening the characteristics of product.  
(9) Do not supply unnecessary stress to lead.  
(10) Please pay careful attention to the lens.  
It might have a chance to miss-function when the lens get dust or dirty. And also please do not touch the lens.  
(11) In order to prevent IC from ESD, human body and solder iron, etc. are required to be grounded.  
Rev.A  
5/7  
RPM7157-R series  
Photo Link Module  
zElectrical and optical characteristics curves  
120  
100  
80  
0.00  
2.00  
4.00  
6.00  
60  
40  
20  
0
8.00  
700 750 800 850 900 950 1000 1050 1100 1150 1200  
10.00  
Wave length : λ (nm)  
4  
3  
2  
1  
fo  
+1  
+2  
+3  
+4  
Frequency : (kHz)  
Fig.7 Optical bandwidth of the  
photo-diode encapsulation  
Fig.6 RPM7157 Series BPF Characteristics  
100  
100  
80  
60  
40  
20  
80  
60  
40  
20  
0
0
80 60  
40  
20  
0
20  
40  
60  
80  
80 60  
40  
20  
0
20  
40  
60  
80  
Angle : (˚)  
Angle : (˚)  
Fig.8 Direction characteristic  
(Horizontal direction)  
Fig.9 Direction characteristic  
(Vertical direction)  
Rev.A  
6/7  
RPM7157-R series  
Photo Link Module  
zDimensions (Unit : mm)  
9.0  
6.0  
1.8  
7.3  
7.30  
4.8  
3.2  
6.0  
0.8  
7.20  
3.60  
3.60  
0.4  
1
2
3
1
2 3  
0.50  
2.54  
0.5  
0.4  
2.54  
2.5  
0.5  
0.6  
1.4  
1.4  
4.6  
6.3  
0.6  
2.54 2.54  
1.80  
RSIP-A3 (H13)  
RSIP-A3 (H8)  
RSIP-A3  
7.30  
15.9  
7.3  
12.00  
3.6  
1.8  
3.60  
0.5  
0.50  
2.54  
1
2 3  
3.60  
2.54  
2.54  
2.54  
4.2  
4.8  
3.2  
6.0  
2
0.8  
1.80  
1
3
20.0min  
2.542.54  
RSIP-A3 (H4)  
RSIP-A3 (H9)  
RSIP-A3 V4  
9.0  
6.0  
1.8  
7.3  
0.4  
2.5  
0.5  
0.6  
Pin No.  
0.6  
Rout  
GND  
1.4  
1.4  
4.6  
6.3  
VCC  
RSIP-A3 (H5)  
Rev.A  
7/7  
Appendix  
Notes  
No technical content pages of this document may be reproduced in any form or transmitted by any  
means without prior permission of ROHM CO.,LTD.  
The contents described herein are subject to change without notice. The specifications for the  
product described in this document are for reference only. Upon actual use, therefore, please request  
that specifications to be separately delivered.  
Application circuit diagrams and circuit constants contained herein are shown as examples of standard  
use and operation. Please pay careful attention to the peripheral conditions when designing circuits  
and deciding upon circuit constants in the set.  
Any data, including, but not limited to application circuit diagrams information, described herein  
are intended only as illustrations of such devices and not as the specifications for such devices. ROHM  
CO.,LTD. disclaims any warranty that any use of such devices shall be free from infringement of any  
third party's intellectual property rights or other proprietary rights, and further, assumes no liability of  
whatsoever nature in the event of any such infringement, or arising from or connected with or related  
to the use of such devices.  
Upon the sale of any such devices, other than for buyer's right to use such devices itself, resell or  
otherwise dispose of the same, no express or implied right or license to practice or commercially  
exploit any intellectual property rights or other proprietary rights owned or controlled by  
ROHM CO., LTD. is granted to any such buyer.  
Products listed in this document are no antiradiation design.  
The products listed in this document are designed to be used with ordinary electronic equipment or devices  
(such as audio visual equipment, office-automation equipment, communications devices, electrical  
appliances and electronic toys).  
Should you intend to use these products with equipment or devices which require an extremely high level of  
reliability and the malfunction of with would directly endanger human life (such as medical instruments,  
transportation equipment, aerospace machinery, nuclear-reactor controllers, fuel controllers and other  
safety devices), please be sure to consult with our sales representative in advance.  
About Export Control Order in Japan  
Products described herein are the objects of controlled goods in Annex 1 (Item 16) of Export Trade Control  
Order in Japan.  
In case of export from Japan, please confirm if it applies to "objective" criteria or an "informed" (by MITI clause)  
on the basis of "catch all controls for Non-Proliferation of Weapons of Mass Destruction.  
Appendix1-Rev1.1  

相关型号:

RPM7157-H9

IR Receiver Module
ROHM

RPM7157-H9R

IR Receiver Module
ROHM

RPM7157-R

IR Receiver Module
ROHM

RPM7157-V4

IR Receiver Module
ROHM

RPM7157-V4R

IR Receiver Module
ROHM

RPM7200

IR Receiver Module
ROHM

RPM7200SERIES

フォトリンクモジュール
ETC

RPM7236

IR Receiver Module
ROHM

RPM7236-H13

Logic IC Output Optocoupler, 1-Channel, PLASTIC, RSIP-A3, 3 PIN
ROHM

RPM7236-H13R

IR Receiver Module
ROHM

RPM7236-H4R

IR Receiver Module
ROHM

RPM7236-H5

Logic IC Output Optocoupler, 1-Channel, PLASTIC, RSIP-A3, 3 PIN
ROHM