VS6V0UA1VWMTF [ROHM]

VS6V0UA1VWMTF是一款用于浪涌保护、电压控制和电压限制的TVS二极管。是符合AEC-Q101标准的高可靠性车规级产品。该产品用更小型的PMDE封装实现了与ROHM以往产品同等的电气特性。PMDE是可靠性高、散热性能优异的封装形式。;
VS6V0UA1VWMTF
型号: VS6V0UA1VWMTF
厂家: ROHM    ROHM
描述:

VS6V0UA1VWMTF是一款用于浪涌保护、电压控制和电压限制的TVS二极管。是符合AEC-Q101标准的高可靠性车规级产品。该产品用更小型的PMDE封装实现了与ROHM以往产品同等的电气特性。PMDE是可靠性高、散热性能优异的封装形式。

二极管 电视
文件: 总10页 (文件大小:1935K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
VS6V0UA1VWMTF  
Transient Voltage Suppressor  
(AEC-Q101 qualified)  
Outline  
Data sheet  
V
V
W
A
6
RWM  
P
200  
19.4  
PP  
I
PP  
Feature  
Inner Circuit  
High reliability  
Small mold type  
Application  
Packaging Specification  
Packing  
Surge protection  
Embossed Tape  
Voltage regulation  
Reel Size(mm)  
Taping Width(mm)  
Quantity(pcs)  
180  
8
3000  
TR  
Structure  
Silicon Epitaxial Planar  
Taping Code  
Marking  
BW  
(T = 25)  
Absolute Maximum Rating  
a
Min. Max.  
Parameter  
Peak Pulse Power  
Peak Pulse Current  
Power dissipation  
Junction temperature  
Storage temperature  
Symbol  
Conditions  
Unit  
W
A
P
tp=10/1000μs  
-
-
-
-
200  
19.4  
1
150  
150  
30  
pp  
I
tp=10/1000μs  
on Glass-epoxysubstrate  
pp  
P
W
D
T
-
-
j
T
stg  
-55  
-
IEC61000-4-2  
Air  
Contact  
kV  
kV  
V
ESD  
ESD capability  
C =150pF, R =330Ω  
S
d
-
30  
www.rohm.com  
©2022- ROHMCo., Ltd.All rights reserved.  
1/7  
2022/01/18_Rev.002  
VSxxVUA1VWM series  
Characteristic (Ta = 25ºC)  
Data sheet  
Symbol  
Breakdown voltage  
(1)  
Stand-off voltage  
Reverse Current  
Clamping voltage  
Part Number  
V
RWM  
(V)  
I (µA)  
R
V
CL  
(V)  
I
V
BR  
(V)  
I (mA)  
V (V)  
5.0  
(A)  
Min.  
6.40  
6.80  
7.50  
8.20  
10.0  
12.0  
13.3  
14.7  
16.2  
18.0  
18.8  
20.0  
22.0  
24.0  
27.0  
28.6  
33.0  
36.0  
40.0  
44.0  
Max.  
7.20  
7.70  
8.40  
9.30  
11.2  
12.2  
15.0  
16.5  
18.3  
20.3  
21.2  
22.4  
24.5  
27.6  
30.8  
32.1  
37.0  
40.0  
46.0  
50.0  
Max.  
5.0  
6.0  
6.5  
7.5  
9.0  
11  
12  
13  
15  
16  
17  
18  
20  
22  
24  
26  
30  
33  
36  
40  
Max.  
5.0  
Max.  
T
R
PP  
VS5V0UA1VWM  
VS6V0UA1VWM  
VS6V5UA1VWM  
VS7V5UA1VWM  
VS9V0UA1VWM  
VS11VUA1VWM  
VS12VUA1VWM  
VS13VUA1VWM  
VS15VUA1VWM  
VS16VUA1VWM  
VS17VUA1VWM  
VS18VUA1VWM  
VS20VUA1VWM  
VS22VUA1VWM  
VS24VUA1VWM  
VS26VUA1VWM  
VS30VUA1VWM  
VS33VUA1VWM  
VS36VUA1VWM  
VS40VUA1VWM  
40  
40  
40  
40  
40  
20  
20  
20  
20  
20  
20  
20  
10  
10  
10  
10  
10  
10  
10  
10  
9.2  
21.7  
26  
20  
7.5  
6.0  
6.5  
7.5  
9.0  
11  
10.3  
11.2  
12.9  
15.4  
18.2  
19.9  
21.5  
24.4  
26.0  
27.6  
29.2  
32.4  
35.5  
38.9  
42.1  
48.4  
53.3  
58.1  
64.5  
19.4  
17.9  
15.5  
13.0  
11.0  
10.1  
9.3  
8.2  
7.7  
7.2  
6.8  
6.2  
5.6  
5.1  
4.8  
4.1  
3.8  
3.4  
3.1  
0.10  
0.10  
0.10  
0.10  
0.10  
0.10  
0.10  
0.10  
0.10  
0.10  
0.10  
0.10  
0.10  
0.10  
0.10  
0.10  
12  
13  
15  
16  
17  
18  
20  
22  
24  
26  
30  
33  
36  
40  
Marking  
Part Number  
VS5V0UA1VWM  
VS6V0UA1VWM  
VS6V5UA1VWM  
VS7V5UA1VWM  
VS9V0UA1VWM  
VS11VUA1VWM  
VS12VUA1VWM  
VS13VUA1VWM  
VS15VUA1VWM  
VS16VUA1VWM  
Part Number  
Marking  
AW  
Marking  
VS17VUA1VWM  
VS18VUA1VWM  
VS20VUA1VWM  
VS22VUA1VWM  
VS24VUA1VWM  
VS26VUA1VWM  
VS30VUA1VWM  
VS33VUA1VWM  
VS36VUA1VWM  
VS40VUA1VWM  
QW  
RW  
SW  
TW  
UW  
VW  
XW  
YW  
ZW  
AX  
BW  
CW  
EW  
GW  
JW  
KW  
LW  
NW  
PW  
www.rohm.com  
©2022- ROHMCo., Ltd.All rights reserved.  
2/7  
2022/01/18_Rev.002  
VS6V0UA1VWMTF  
Data sheet  
Characteristic Curves  
www.rohm.com  
©2022- ROHMCo., Ltd.All rights reserved.  
3/7  
2022/01/18_Rev.002  
VS6V0UA1VWMTF  
Data sheet  
Characteristic Curves  
www.rohm.com  
©2022- ROHMCo., Ltd.All rights reserved.  
4/7  
2022/01/18_Rev.002  
VS6V0UA1VWMTF  
Data sheet  
Characteristic Curves  
www.rohm.com  
©2022- ROHMCo., Ltd.All rights reserved.  
5/7  
2022/01/18_Rev.002  
VS6V0UA1VWMTF  
Data sheet  
Appended figure  
Procedure to obtain ESD Clampimg Voltage  
IEC61000-4-2 Spec  
IEC61000-4-2 Waveform  
C :150pFR :330Ω  
S
d
simplified diagram in ESD machine  
1Set up ESD Tester at IEC61000-4-2 condition.  
(IEC61000-4-2 C=150pF, R=330Ω)  
2Mount a sample on the high frequency test board  
with the SMAconnector.  
3Connect the SMAconnector to the oscilloscope  
by 50Ωcable.  
Then, add the 10X-attenuator between test board  
and the cable to protect the oscilloscope.  
4Discharge ESD in contact discharge mode at any voltage.  
(normally 8kV Max.)  
www.rohm.com  
©2022- ROHMCo., Ltd.All rights reserved.  
6/7  
2022/01/18_Rev.002  
VS6V0UA1VWMTF  
Data sheet  
Dimension  
PMDE  
Taping (Unit:mm)  
www.rohm.com  
©2022- ROHMCo., Ltd.All rights reserved.  
7/7  
2022/01/18_Rev.002  
Notice  
Precaution on using ROHM Products  
(Note 1)  
1. If you intend to use our Products in devices requiring extremely high reliability (such as medical equipment  
,
aircraft/spacecraft, nuclear power controllers, etc.) and whose malfunction or failure may cause loss of human life,  
bodily injury or serious damage to property (Specific Applications), please consult with the ROHM sales  
representative in advance. Unless otherwise agreed in writing by ROHM in advance, ROHM shall not be in any way  
responsible or liable for any damages, expenses or losses incurred by you or third parties arising from the use of any  
ROHMs Products for Specific Applications.  
(Note1) Medical Equipment Classification of the Specific Applications  
JAPAN  
USA  
EU  
CHINA  
CLASS  
CLASSⅣ  
CLASSb  
CLASSⅢ  
CLASSⅢ  
CLASSⅢ  
2. ROHM designs and manufactures its Products subject to strict quality control system. However, semiconductor  
products can fail or malfunction at a certain rate. Please be sure to implement, at your own responsibilities, adequate  
safety measures including but not limited to fail-safe design against the physical injury, damage to any property, which  
a failure or malfunction of our Products may cause. The following are examples of safety measures:  
[a] Installation of protection circuits or other protective devices to improve system safety  
[b] Installation of redundant circuits to reduce the impact of single or multiple circuit failure  
3. Our Products are not designed under any special or extraordinary environments or conditions, as exemplified below.  
Accordingly, ROHM shall not be in any way responsible or liable for any damages, expenses or losses arising from the  
use of any ROHM’s Products under any special or extraordinary environments or conditions. If you intend to use our  
Products under any special or extraordinary environments or conditions (as exemplified below), your independent  
verification and confirmation of product performance, reliability, etc, prior to use, must be necessary:  
[a] Use of our Products in any types of liquid, including water, oils, chemicals, and organic solvents  
[b] Use of our Products outdoors or in places where the Products are exposed to direct sunlight or dust  
[c] Use of our Products in places where the Products are exposed to sea wind or corrosive gases, including Cl2,  
H2S, NH3, SO2, and NO2  
[d] Use of our Products in places where the Products are exposed to static electricity or electromagnetic waves  
[e] Use of our Products in proximity to heat-producing components, plastic cords, or other flammable items  
[f] Sealing or coating our Products with resin or other coating materials  
[g] Use of our Products without cleaning residue of flux (Exclude cases where no-clean type fluxes is used.  
However, recommend sufficiently about the residue.); or Washing our Products by using water or water-soluble  
cleaning agents for cleaning residue after soldering  
[h] Use of the Products in places subject to dew condensation  
4. The Products are not subject to radiation-proof design.  
5. Please verify and confirm characteristics of the final or mounted products in using the Products.  
6. In particular, if a transient load (a large amount of load applied in a short period of time, such as pulse, is applied,  
confirmation of performance characteristics after on-board mounting is strongly recommended. Avoid applying power  
exceeding normal rated power; exceeding the power rating under steady-state loading condition may negatively affect  
product performance and reliability.  
7. De-rate Power Dissipation depending on ambient temperature. When used in sealed area, confirm that it is the use in  
the range that does not exceed the maximum junction temperature.  
8. Confirm that operation temperature is within the specified range described in the product specification.  
9. ROHM shall not be in any way responsible or liable for failure induced under deviant condition from what is defined in  
this document.  
Precaution for Mounting / Circuit board design  
1. When a highly active halogenous (chlorine, bromine, etc.) flux is used, the residue of flux may negatively affect product  
performance and reliability.  
2. In principle, the reflow soldering method must be used on a surface-mount products, the flow soldering method must  
be used on a through hole mount products. If the flow soldering method is preferred on a surface-mount products,  
please consult with the ROHM representative in advance.  
For details, please refer to ROHM Mounting specification  
Notice-PAA-E  
Rev.004  
© 2015 ROHM Co., Ltd. All rights reserved.  
Precautions Regarding Application Examples and External Circuits  
1. If change is made to the constant of an external circuit, please allow a sufficient margin considering variations of the  
characteristics of the Products and external components, including transient characteristics, as well as static  
characteristics.  
2. You agree that application notes, reference designs, and associated data and information contained in this document  
are presented only as guidance for Products use. Therefore, in case you use such information, you are solely  
responsible for it and you must exercise your own independent verification and judgment in the use of such information  
contained in this document. ROHM shall not be in any way responsible or liable for any damages, expenses or losses  
incurred by you or third parties arising from the use of such information.  
Precaution for Electrostatic  
This Product is electrostatic sensitive product, which may be damaged due to electrostatic discharge. Please take proper  
caution in your manufacturing process and storage so that voltage exceeding the Products maximum rating will not be  
applied to Products. Please take special care under dry condition (e.g. Grounding of human body / equipment / solder iron,  
isolation from charged objects, setting of Ionizer, friction prevention and temperature / humidity control).  
Precaution for Storage / Transportation  
1. Product performance and soldered connections may deteriorate if the Products are stored in the places where:  
[a] the Products are exposed to sea winds or corrosive gases, including Cl2, H2S, NH3, SO2, and NO2  
[b] the temperature or humidity exceeds those recommended by ROHM  
[c] the Products are exposed to direct sunshine or condensation  
[d] the Products are exposed to high Electrostatic  
2. Even under ROHM recommended storage condition, solderability of products out of recommended storage time period  
may be degraded. It is strongly recommended to confirm solderability before using Products of which storage time is  
exceeding the recommended storage time period.  
3. Store / transport cartons in the correct direction, which is indicated on a carton with a symbol. Otherwise bent leads  
may occur due to excessive stress applied when dropping of a carton.  
4. Use Products within the specified time after opening a humidity barrier bag. Baking is required before using Products of  
which storage time is exceeding the recommended storage time period.  
Precaution for Product Label  
A two-dimensional barcode printed on ROHM Products label is for ROHMs internal use only.  
Precaution for Disposition  
When disposing Products please dispose them properly using an authorized industry waste company.  
Precaution for Foreign Exchange and Foreign Trade act  
Since concerned goods might be fallen under listed items of export control prescribed by Foreign exchange and Foreign  
trade act, please consult with ROHM in case of export.  
Precaution Regarding Intellectual Property Rights  
1. All information and data including but not limited to application example contained in this document is for reference  
only. ROHM does not warrant that foregoing information or data will not infringe any intellectual property rights or any  
other rights of any third party regarding such information or data.  
2. ROHM shall not have any obligations where the claims, actions or demands arising from the combination of the  
Products with other articles such as components, circuits, systems or external equipment (including software).  
3. No license, expressly or implied, is granted hereby under any intellectual property rights or other rights of ROHM or any  
third parties with respect to the Products or the information contained in this document. Provided, however, that ROHM  
will not assert its intellectual property rights or other rights against you or your customers to the extent necessary to  
manufacture or sell products containing the Products, subject to the terms and conditions herein.  
Other Precaution  
1. This document may not be reprinted or reproduced, in whole or in part, without prior written consent of ROHM.  
2. The Products may not be disassembled, converted, modified, reproduced or otherwise changed without prior written  
consent of ROHM.  
3. In no event shall you use in any way whatsoever the Products and the related technical information contained in the  
Products or this document for any military purposes, including but not limited to, the development of mass-destruction  
weapons.  
4. The proper names of companies or products described in this document are trademarks or registered trademarks of  
ROHM, its affiliated companies or third parties.  
Notice-PAA-E  
Rev.004  
© 2015 ROHM Co., Ltd. All rights reserved.  
Daattaasshheeeett  
General Precaution  
1. Before you use our Pro ducts, you are requested to care fully read this document and fully understand its contents.  
ROHM shall not be in an y way responsible or liable for failure, malfunction or accident arising from the use of a ny  
ROHM’s Products against warning, caution or note contained in this document.  
2. All information contained in this docume nt is current as of the issuing date and subj ect to change without any prior  
notice. Before purchasing or using ROHM’s Products, please confirm the la test information with a ROHM sale s  
representative.  
3. The information contained in this doc ument is provi ded on an “as is” basis and ROHM does not warrant that all  
information contained in this document is accurate an d/or error-free. ROHM shall not be in an y way responsible or  
liable for any damages, expenses or losses incurred by you or third parties resulting from inaccuracy or errors of or  
concerning such information.  
Notice – WE  
Rev.001  
© 2015 ROHM Co., Ltd. All rights reserved.  

相关型号:

VS6V3UC1QS

VS6V3UC1QS为超小型封装(1006尺寸)的瞬态电压抑制器。非常适用于电子设备的接口保护和电池保护。

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ROHM

VS6V5UA1VWM

VS6V5UA1VWM是一款用于浪涌保护、电压控制和电压限制的TVS二极管。该产品用更小型的PMDE封装实现了与ROHM以往产品同等的电气特性。PMDE是可靠性高、散热性能优异的封装形式。

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ROHM

VS6V5UA1VWMTF

VS6V5UA1VWMTF是一款用于浪涌保护、电压控制和电压限制的TVS二极管。是符合AEC-Q101标准的高可靠性车规级产品。该产品用更小型的PMDE封装实现了与ROHM以往产品同等的电气特性。PMDE是可靠性高、散热性能优异的封装形式。

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ROHM

VS7-1-A02

SUB BASE

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ETC

VS7-1-A03

SUB BASE

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ETC

VS7-2-A03

SUB BASE

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ETC

VS7-2-A04

SUB BASE

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ETC

VS7-2-A06

SUB BASE

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ETC

VS7-6-FG-D-3Z-Q

VALVE 5/2 24DC

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ETC

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ETC

VS7-6-FG-S-3Z-Q

VALVE ISO 1 5/2 24DC

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ETC

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
ETC