GENERAL DESCRIPTION  
FEATURES  
SM3015 is a multi-function Fan Controller * High performance CMOS technology.  
CMOS IC that can be applied to a variety of * Rhythm wind or Normal wind for SLEEP  
consumer products. It has an elastic  
mode can be chosen.  
function like MCU but does not need * Two to three-wind grade control in wind  
programming, user can just write a MASK  
form.  
modes.  
* Memory start-up function option.  
SM3015 has three or four wind modes; * Many types of timer setting on three or four  
normal, rhythm and sleep-rhythm wind or  
normal, rhythm, sleep-normal and sleep-  
steps and ladder adder or non-ladder  
adder.  
rhythm, the operation pattern of rhythm and * Two swing head control, micro-swing output  
sleep modes can be set by user. can be chosen by MASK option.  
Many kinds of timer setting and two swing * SPEED or ON/OFF key can enable fan  
head control that include micro-swing output controller.  
can be chosen by user to tune the swing * 16 or 32 patterns per cycle of rhythm/sleep  
head angle. mode, each pattern has 2.5 sec.  
Memory or non-memory function is * Panel control or pair with SM5021B for an  
available; the Speed, Mode, Swing functions  
will operate as last state in memory type.  
infrared Remote Fan Controller.  
* 16/18/20/22/24 pin plastic DIP package.  
Supports two-bit customer codes to * Three types of sleep hold time by SLT key:  
distinguish different models.  
0.5hr/1hr/2hr.  
* 32.768KHz/455KHz oscillator option.  
APPLICATIONS  
PIN ASSIGNMENTS (TOP VIEW)  
* Electronic Fan  
1
2
3
4
5
6
7
8
9
22  
21  
20  
19  
18  
17  
16  
15  
14  
13  
12  
1
2
3
4
5
6
7
8
9
22  
21  
20  
19  
18  
17  
16  
15  
14  
13  
12  
LTO  
VSS  
OSC1  
OSC2  
BUZ  
VDD  
LOW  
MEDIUM  
STRONG  
SHO1  
SHO2  
LTO  
VSS  
OSC1  
OSC2  
BUZ  
VDD  
LOW  
MEDIUM  
STRONG  
SHO1  
SHO2  
LIGHT  
LIGHT  
DI  
OFF(ON/OFF)  
TIMER  
SPEED  
MODE  
* Heater Fan  
* Air-Cleaner  
* Dehumidifier  
* Humidifier  
* Kitchen Exhaust  
* Dish Dryer  
* Wall Fan  
DI  
OFF(ON/OFF)  
TIMER  
SPEED  
MODE  
COM1  
COM2  
COM3  
SWING1  
SWING2  
COM1  
COM2  
COM3  
SWING1  
NC  
10  
11  
10  
11  
SM3015A 16/18/20/22PIN  
SM3015B 16/18/20/22PIN  
Page 1  
V.2.0 Mar 8 ,2002  
SM3015  
S
AM  
HOP Microelectronics Corp.  
REMOTE FAN MCU  
PIN ASSIGNMENT (TOP VIEW)  
1
2
3
4
5
6
7
8
9
24  
23  
22  
21  
20  
19  
18  
17  
16  
15  
14  
13  
1
2
3
4
5
6
7
8
9
24  
23  
22  
21  
20  
19  
18  
17  
16  
15  
14  
13  
LTO  
VSS  
OSC1  
OSC2  
BUZ  
LIGHT  
DI  
LTO  
VSS  
OSC1  
OSC2  
BUZ  
LIGHT  
DI  
OFF(ON/OFF)  
TIMER  
OFF(ON/OFF)  
TIMER  
SPEED  
MODE  
COM1  
SPEED  
MODE  
COM1  
COM2  
COM3  
SWING1  
SWING2  
SLT  
VDD  
LOW  
VDD  
LOW  
MEDIUM  
STRONG  
SHO1  
SHO2  
NC  
COM2  
COM3  
SWING1  
SLT  
MEDIUM  
STRONG  
SHO1  
SHO2  
NC  
10  
11  
12  
10  
11  
12  
NC  
SM3015C 24PIN  
SM3015D 20/24PIN  
PANEL DISPLAY  
(SWING FUNCTION)  
(SWING FUNCTION)  
SLP-RHY  
4HR  
S
M
L
2HR  
1HR  
1/2HR  
SLP-NOR  
RHY  
SHO1  
SHO2  
Right  
Left Up Down  
NOR  
SHO1  
SHO2  
MODE  
SW1  
TUNER1 TUNER2  
SW2  
SWING  
LIGHT  
OFF  
ON/OFF  
SPEED TIMER  
SM3015A TYPE  
SM3015B TYPE  
(SWING FUNCTION)  
(SWING FUNCTION)  
SLP-RHY  
SLP-NOR  
RHY  
4HR  
2 HR  
2HR  
S
M
L
2HR  
Right  
Left Up  
Down  
1HR  
SHO1  
SHO2  
1 HR  
1HR  
SHO1  
SHO2  
1/2HR  
NOR  
1/2HR  
1/2 HR  
SW1  
SW2  
SLEEP  
MODE  
OFF SPEED TIMER  
ON/OFF  
LIGHT  
SLEEP  
HOLD TIME  
SWING  
TUNER1 TUNER2 HOLD TIME  
SM3015C TYPE  
SM3015D TYPE  
* Note: " " Functions can be chosen by MASK or bonding option.  
Page 2  
V.2.0 Mar 8, 2002  
SM3015  
S
AM  
HOP Microelectronics Corp.  
REMOTE FAN MCU  
BLOCK DIAGRAM  
VDD  
VSS  
DI  
OSC1  
OSCILLATOR  
BUZ  
BUZZER  
REMOTE CONTROL DECODER  
OSC2  
OFF  
STRONG  
FAN FUNCTIONS CONTROL  
SPEED  
SPEED/MODE/TIMER/MEMORY  
TIMER  
MODE  
SLEEP  
KEY INPUT  
LED OUTPUT  
SCAN_SIGNAL  
SPEED  
OUTPUT  
DRIVER  
MEDIUM  
LOW  
COM1  
COM2  
ROM  
TIMER  
COM3  
SWING1  
SWING2  
LIGHT  
SWING/LIGHT  
CONTROL  
SYSTEM TIMING GENERATOR  
ZERO_CROSS  
SHO1 SHO2 LTO  
Page 3  
V.2.0 Mar 8, 2002  
SM3015  
S
AM  
HOP Microelectronics Corp.  
REMOTE FAN MCU  
PIN DESCRIPTIONS  
No.  
1
Pin Name  
LIGHT  
I / O  
I
Function  
Light control input  
2
DI  
I
Remote control input  
3
ON_OFF/OFF  
TIMER  
SPEED  
MODE  
I/O  
I/O  
I/O  
I/O  
O
On-Off or Off function control input  
Timer setting input  
4
5
Wind grade selection input  
Wind mode selection input  
LED scanning common pin / Customer code  
LED scanning common pin / Customer code  
LED scanning common pin  
Swing head control input / Customer code  
Swing head control input  
Sleep time control input  
6
7
COM1  
8
COM2  
O
9
COM3  
O
10  
11  
12  
SWING1  
SWING2  
SLT  
I
I
I/O  
NC  
SHO2  
SHO1  
STRONG  
MEDIUM  
LOW  
No connection  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
O
Swing head / tuner pulse output  
Swing head / tuner pulse output  
Wind speed control output  
Wind speed control output  
Wind speed control output  
Positive power supply  
O
O
O
O
VDD  
POWER  
BUZ  
O
Trigger output to drive piezo  
Crystal output  
OSC2  
OSC1  
VSS  
O
I
POWER  
O
Crystal input  
Negative power supply (Substrate)  
Light control output  
LTO  
Page 4  
V.2.0 Mar 8, 2002  
SM3015  
S
AM  
HOP Microelectronics Corp.  
REMOTE FAN MCU  
FUNCTION DESCRIPTION  
SM3015 has two control types : panel keypad and infrared remote control.  
There are four to eight control signal operations :  
* Start-up by SPEED key  
a. function turn off (OFF key)  
b. wind mode select (MODE key)  
c. start-up function and wind speed select (SPEED key)  
d. timer setting (TIMER key)  
e. swing head or tuner for swing angle (SW1 and SW2 key)  
f. lighting control (LIGHT key)  
* Start-up by ON/OFF key  
a. function control (ON/OFF key)  
b. wind mode select (MODE key)  
c. wind speed select (SPEED key)  
d. timer setting (TIMER key)  
e. swing head or tuner for swing angle (SW1 and SW2 key)  
f. lighting control (LIGHT key)  
All functions can be planned by user like an MCU for more product application.  
Only SPEED or ON/OFF key can enable the fan controller, except for the light control. Wind mode,  
timer and swing head inputs can not be accepted when fan is not activated. The fan controller will be  
turned off by timer and OFF (ON/OFF) key inputs.  
When more than one key are pressed, controller will not accept the multi-key's control signal, if the  
panel keys are pressed more than six seconds, controller will generate a " BI-BI-BI-BI" warning sound.  
When fan is enabled by SPEED or ON/OFF key, the initial state of fan controller is as follows:  
* Memory function available  
If Fan controller is OFF on sleep mode, all memory functions will be returned to the LAST TURN  
ON STATE.  
a.Grade as last state but with starting medium wind for three seconds (MASK option)  
b. The wind mode as last state except sleep mode  
c. Swing function as last state  
d. Timer setting off  
e. Light is independent  
* Non-memory function (Bonding option)  
a. Grade is low wind function but with starting medium wind for three seconds (MASK option)  
b. Normal wind mode operation  
c. Timer setting and swing head off  
d. Light is independent  
Page 5  
V.2.0 Mar 8, 2002  
SM3015  
S
AM  
HOP Microelectronics Corp.  
REMOTE FAN MCU  
A. OFF KEY  
When fan controller is on, press the OFF key on panel or remote control handset, fan  
functions will be turned off except light output.  
* BONDING OPTION : ON/OFF KEY  
When fan controller functions are on, press ON/OFF key on panel or remote control  
handset, fan functions will be turned off; if functions are off, press the key to turn on fan  
functions. Light output is independent.  
B. SPEED KEY  
When fan control is off, press SPEED key on panel or remote control handset, fan is turned  
on; when memory function is available, the wind grade will operate as last state. Both  
conditions have three seconds starting wind. Press the SPEED key again, the wind will be  
changed as follows :  
OFF  
LOW  
MEDIUM  
STRONG  
SPEED key used  
Pulse is put into OFF pin  
* BONDING OPTION: SPEED KEY ONLY  
If fan controller is off, SPEED key cannot be used, must press ON/OFF key to turn on the  
fan controller. When fan controller is on, press SPEED key on panel or remote control  
handset and wind grade changes as follows:  
OFF  
LOW  
MEDIUM  
STRONG  
SPEED key used  
Pulse is put into ON/OFF pin  
Page 6  
V.2.0 Mar 8, 2002  
SM3015  
S
AM  
HOP Microelectronics Corp.  
REMOTE FAN MCU  
* MASK OPTION: WIND GRADE  
a. There are two types of wind grade control function to choose. If fan controller is on,  
press SPEED key on panel or remote control handset, wind grade changes as follows:  
1. OFF  
LOW  
MEDIUM  
STRONG  
STRONG  
2. OFF  
LOW  
SPEED key used  
SPEED key or ON/OFF key used  
b. Memory or non-memory function can be chosen.  
C. MODE KEY  
SM3015 has four types of wind mode: normal, rhythm, sleep + rhythm, and sleep + normal  
these can be chosen by mode key setting. Memory function is available except on sleep  
mode.  
1. OFF  
NOR  
RHY  
SLP-RHY  
: Press MODE key: normal setting  
: Pulse is put into OFF or ON/OFF pin  
: SPEED or ON/OFF key used  
Page 7  
V.2.0 Mar 8, 2002  
SM3015  
S
AM  
HOP Microelectronics Corp.  
REMOTE FAN MCU  
* MASK OPTION:  
a. Memory or non-memory function can be chosen.  
b. There are five kinds of wind mode operation.  
OFF  
OFF  
NOR  
NOR  
RHY  
OFF  
NOR  
RHY  
SLP  
(RHY)  
OFF  
OFF  
NOR  
NOR  
RHY  
RHY  
SLP  
(NOR)  
SLP  
SLP  
(NOR)  
(RHY)  
Press MODE key: normal setting  
Pulse is put into OFF or ON/OFF pin  
SPEED or ON/OFF key used  
D. LIGHTING CONTROL KEY  
The LIGHT key is independent and the output is toggle function. When the LIGHT key is  
pressed on panel or remote control handset, operation is as follows :  
OFF  
Light output key  
Press LIGHT key  
* MASK OPTION:  
Fan controller is off, LIGHT key cannot be used.  
Page 8  
V.2.0 Mar 8, 2002  
SM3015  
S
AM  
HOP Microelectronics Corp.  
REMOTE FAN MCU  
E. TIMER KEY SETTING  
SM3015 has many types of timer  
adder for three or four steps. Timer key will not activate when fan controller is off. These types  
of timer may be chosen by bonding option.  
MODE A: Timer with accumulation  
Four-steps Type  
A*1 A*2 A*3 A*4  
Three-steps Type  
A*1 A*2 A*3  
Timer Pulse No.  
1
2
3
4
5
6
7
8
9
10  
11  
12  
13  
14  
15  
MODE B: Timer with non-accumulation  
Four-steps Type  
Three-steps Type  
Timer Pulse No.  
A
B
C
D
A
B
C
1
2
3
4
LED display  
* MASK OPTION:  
A,B,C,D time base are common multiple by 15 minute ascending, and each number can be  
set by user.  
Page 9  
V.2.0 Mar 8, 2002  
SM3015  
S
AM  
HOP Microelectronics Corp.  
REMOTE FAN MCU  
F. SWING KEY:SWING1 AND SWING2  
The swing key will not activate when fan controller is off. Memory function is available, the  
swing output will operate as last state when press SPEED or ON/OFF key, except tuner function  
using.  
A/C Type :  
SM3015A has two keys of SW1 and SW2 to control the outputs of SHO1 and SHO2 (toggle  
function).  
OFF  
SHO1 enable  
(Right / Left)  
The SW1 key pressed  
OFF  
SHO2 enable  
(Up /Down)  
The SW2 key pressed  
When SHO1 and SHO2 outputs enable together, the swing head has 3D function.  
B/D Type :  
SM3015B/D has only one SWING key to control the outputs of SHO1 and SHO2.  
OFF  
SHO1(Right & Left)  
SHO2(Up & Down)  
3D  
:The SWING key pressed  
* MASK OPTION :  
a. SHO1 and SHO2 output can be enabled when fan controller is off.  
b. SHO1 and SHO2 output functions can be chosen as a continuous outputs respectively like a  
micro-swing switch to tune the swing angle.  
Page 10  
V.2.0 Mar 8, 2002  
SM3015  
S
AM  
HOP Microelectronics Corp.  
REMOTE FAN MCU  
G. SLT KEY  
When fan controller functions are on, pres  
the sleep mode, then press the SLT key to set the timer of the wind grade down. The time base of  
SLT key is 0.5HR/1HR/2HR.  
H. MEMORY FUNCTION  
Memory of speed, mode(except sleep mode) and swing functions can be set independently.  
Memory function can be cancelled by Bonding option. When memory function is available, wind  
speed mode and swing functions will operate as last state; if last state is sleep mode, press  
SPEED or ON/OFF key enable fan controller while memory functions(Speed/Mode/Swing) will be  
returned to the last state before sleep mode operation.  
I. STARTING WIND  
Memory or non-memory type, fan controller starts with three seconds starting wind.  
J. CUSTOMER CODE  
SM3015 provide two-bit customer code to distinguish different product models. There are four  
types, that can be set by diode.  
a. Set code bit to "0", connect diode to COM1/COM2 and SWING/SW1 terminal  
b. Set code bit to "1", open the circuit.  
SWING/SW1 PIN  
D1  
0
D2  
0
D2  
D1  
0
1
1
0
COM1  
PIN  
COM2  
PIN  
1
1
Page 11  
V.2.0 Mar 8, 2002  
SM3015  
S
AM  
HOP Microelectronics Corp.  
REMOTE FAN MCU  
K. BUZZER  
Any key pressed on panel or fan controller receives a control signal from remote control  
handset, will generate a 4KHz 50% duty cycle pulse train on buzzer output pin.  
a. When FAN is from stop mode to start mode (press SPEED or ON_OFF key)  
Buzzer output will generate a "BI-BI" sound.  
a
b
c
b. When FAN is from start mode to stop mode (press OFF/ON_OFF key)  
Buzzer output will generate a long "BI" sound.  
d
c. When FAN is operating (press any key other than OFF/ON_OFF key)  
Buzzer output will generate a "BI" sound.  
e
When a = c = e = 62ms  
b = 124ms  
d = 250ms  
* MASK OPTION  
Fan controller will generate a 150ms duration 2KHz 50% duty cycle pulse train on BUZ output  
pin.  
Page 12  
V.2.0 Mar 8, 2002  
SM3015  
S
AM  
HOP Microelectronics Corp.  
REMOTE FAN MCU  
L-1. RHYTHM WIND FUNCTION (DEFAULT)  
S
M
L
0 2.5 5 7.5 10 12.5 15 17.5 20 22.5 25 27.5 30 32.5 35 37.5 40 42.5 45 47.5 50 52.5 55 57.5 60 62.5 65 67.5 70 72.5 75 77.5 80  
(SEC)  
STRONG RHYTHM WIND PATTERN  
S
M
L
0 2.5 5 7.5 10 12.5 15 17.5 20 22.5 25 27.5 30 32.5 35 37.5 40 42.5 45 47.5 50 52.5 55 57.5 60 62.5 65 67.5 70 72.5 75 77.5 80  
(SEC)  
MEDIUM RHYTHM WIND PATTERN  
S
M
L
0 2.5 5 7.5 10 12.5 15 17.5 20 22.5 25 27.5 30 32.5 35 37.5 40 42.5 45 47.5 50 52.5 55 57.5 60 62.5 65 67.5 70 72.5 75 77.5 80  
(SEC)  
LOW RHYTHM WIND PATTERN  
*MASK OPTION:  
32 patterns per cycle, each pattern (2.5 seconds) can be set by user.  
Page 13  
V.2.0 Mar 8, 2002  
SM3015  
S
AM  
HOP Microelectronics Corp.  
REMOTE FAN MCU  
L-2. RHYTHM WIND FUNCTION (DEFAULT)  
S
M
L
0 2.5 5 7.5 10 12.5 15 17.5 20 22.5 25 27.5 30 32.5 35 37.5 40 42.5 45 47.5 50 52.5 55 57.5 60 62.5 65 67.5 70 72.5 75 77.5 80  
(SEC)  
STRONG RHYTHM WIND PATTERN  
S
M
L
0 2.5 5 7.5 10 12.5 15 17.5 20 22.5 25 27.5 30 32.5 35 37.5 40 42.5 45 47.5 50 52.5 55 57.5 60 62.5 65 67.5 70 72.5 75 77.5 80  
(SEC)  
MEDIUM RHYTHM WIND PATTERN  
S
M
L
0 2.5 5 7.5 10 12.5 15 17.5 20 22.5 25 27.5 30 32.5 35 37.5 40 42.5 45 47.5 50 52.5 55 57.5 60 62.5 65 67.5 70 72.5 75 77.5 80  
(SEC)  
LOW RHYTHM WIND PATTERN  
*MASK OPTION:  
32 patterns per cycle, each pattern (2.5 seconds) can be set by user.  
Page 14  
V.2.0 Mar 8, 2002  
SM3015  
S
AM  
HOP Microelectronics Corp.  
REMOTE FAN MCU  
M. SLEEP FUNCTION  
In sleep mode, wind grade is changed by timing automatically.  
S
M
Strong  
Medium  
Wind  
Wind  
L
Low Wind  
×
×
TIME BASE 1  
TIME BASE 2  
TIME  
TIMER OPTION:  
Sleep Hold Time Key can be chosen the time base of 0.5/1/2HR by SLT key in SM3015C/D  
type only.  
Page 15  
V.2.0 Mar 8, 2002  
SM3015  
S
AM  
HOP Microelectronics Corp.  
REMOTE FAN MCU  
TIMING  
CONTROL  
Speed Key  
On/Off Key  
t
key  
Buz  
Low  
t
buz  
Medium  
Strong  
3 sec.  
Mode Key  
Normal  
Rhythm  
Sleep  
t
key  
Off Key  
On/Off Key  
t
key  
Fan Enable  
* NOTE: tbuz see page 12 and tkey see page 6  
Page 16  
V.2.0 Mar 8, 2002  
SM3015  
S
AM  
HOP Microelectronics Corp.  
REMOTE FAN MCU  
DC ELECTRICAL CHARACTERISTICS  
Limits  
Typ. Max.  
Parameter  
Symbol Test Conditions  
Unit  
Min.  
Supply Voltage  
VDD  
ISB  
3
5
6
V
OSC stop  
all output pins open  
all input fixed to VDD  
Stand-by Current  
500  
uA  
Input High Level  
Input Low Level  
VIH  
VIL  
3.5  
V
V
1.5  
Sink Current  
(OFF,MODE,SPEED  
TIMER,SLEEP)  
IOL  
IOH  
IOL  
IOH  
VOL=+0.7V  
VOH=+4.3V  
VOL=+0.7V  
VOH=+4.3V  
10  
10  
10  
5
mA  
mA  
mA  
mA  
Source Current  
(OFF,MODE,SPEED  
TIMER,SLEEP)  
Triac Sink Current  
(S,M,L,SW1,  
SW2,LIGHT)  
Triac Source Current  
(S,M,L,SW1,  
SW2,LIGHT)  
Sink Current  
(COM1~COM3)  
IOL  
IOH  
IOL  
VOL=+0.7V  
VOH=+4.3V  
VOL=+0.7V  
VOH=+4.3V  
40  
10  
4
mA  
mA  
Source Current  
(COM1~COM3)  
Sink Current  
(BUZ)  
mA  
Source Current  
(BUZ)  
IOH  
RPH  
5
mA  
Pull-high Resister  
(Input pin)  
200  
K OHM  
*NOTE: All test conditions are on VDD = 5V / VSS = GND  
Page 17  
V.2.0 Mar 8, 2002  
SM3015  
S
AM  
HOP Microelectronics Corp.  
REMOTE FAN MCU  
ABSOLUTE MAXIMUM RATINGS  
Parameter  
Symbol  
Test conditions  
Ratings  
Unit  
Supply Voltage  
Input Voltage  
Output Voltage  
VDD-VSS  
Vi-VSS  
Vo-VSS  
Pa  
-0.3~6  
VSS-0.3~VDD+0.3  
VSS-0.3~VDD+0.3  
500  
V
V
V
Maximum Power  
Consumption  
VDD-VSS=5V  
mW  
C
Operating Temperature  
Storage Temperature  
Topr  
-10~70  
Tstg  
-40~125  
C
AC CHARACTERISTICS  
Oscillator Frequency:455KHz/32.768KHz  
Ratings  
Typ.  
Parameter  
Symbol  
t key  
Unit  
Min.  
Max.  
Key Press Duration  
Remote Input Bit Duration  
30  
ms  
ms  
t bit  
1.17  
1.68  
2.18  
Page 18  
V.2.0 Mar 8, 2001  
SM3015  
S
AM  
HOP Microelectronics Corp.  
REMOTE FAN MCU  
SM5021 (ENCODER) APPLICATION CIRCUIT  
R2  
4.7  
D2  
IR LED  
Q1  
NPN  
JP1  
JP2  
C1  
VDD  
DOUT  
BT  
3V  
C2  
OFF  
K1/  
K2/  
K3/  
K4/  
K5/  
LEDO  
ON-OFF  
D1  
LED  
OSC2  
SPEED  
MODE  
TIMER  
C1  
Q2  
OSC1  
NPN  
10u  
SLEEP/K8  
LIGHT/K7  
SW2/K6  
455K  
SW1  
R1  
SWING  
1K  
Vss  
SM5021A/B  
SM3015 POWER SUPPLY APPLICATION CIRCUIT  
100K/1W  
47 / 0.25W  
1A  
VSS/-5.1V  
1N4004  
47 /1W  
3.3uF/250V  
47 / 0.25W  
110V AC INPUT  
5.1V  
0.5W  
220uF  
16V  
470uF  
16V  
1N4004  
GND  
200K / 1W  
47 / 0.25W  
180  
180  
/ 1W  
/ 1W  
1A  
VSS/-5.1V  
1N4004  
1.2uF / 400V  
47 / 0.25W  
220V AC INPUT  
5.1V  
0.5W  
220uF  
16V  
470uF  
16V  
1N4004  
GND  
Page 19  
V.2.0 Mar 8, 2002  
SM3015 APPLICATION CIRCUIT  
AC INPUT  
VDD/GND  
VSS/-5.1V  
100p  
(10p)  
100p  
(10p)  
C1  
C2  
R7 R6  
R5  
R4  
R3  
R2  
R1  
R8  
10K 10K 10K 10K 10K 10K 10K 10K  
455KHz(32.768KHz)  
ON-OFF  
OFF  
SLT  
S1  
LIGHT  
SWING1  
SPEED  
S5 S4  
TIMER  
S7  
S6  
S3  
S2  
S8  
SM3015A/C  
56  
R
MDO  
E
SWING2  
GND VDD  
LTO  
LIGHT  
DI  
VSS  
OSC1  
OSC2  
BUZ  
OFF(ON/OFF)  
TIMER  
SPEED  
MODE  
COM1  
COM2  
COM3  
SW1  
-
DOUT  
+
IR MODULE  
VDD  
R1  
0~100  
0~100  
0~100  
LOW  
MED  
STR  
5
R1  
6
R1  
D2  
7
SW  
SW  
D1  
SHO1  
SHO2  
NC  
SW2  
SLT  
1/2  
1
2
4
SPT 1/2  
* N  
RHY LOW MED ST  
R
SPT1  
pos  
NOR  
SLP+R SLP+N  
SPT2  
Page 20  
LP  
M1  
M2  
M3  
LIGHT  
L
M
S
SW1 SW2  
z)  
R14  
560  
-
C3  
47u  
+
Ω
R9/560  
Ω
R10/560  
Ω
R11/560  
R12/560  
R13/560  
Ω
SW1  
SW2  
Ω
* NOTE: 1. D1 and D2 for custom code.  
Code 1: open the diode  
Code 0: use the diode  
2. C3 must be closed to IC as  
possible of PCB layout.  
3. A Type: SLT PIN = NC  
4. Oscillator Option:  
Option Oscillator  
C1,C2  
100p  
10p  
1
2
455KHz  
32.768KHz  
V.2.0 Mar 8, 2002  
SM3015 APPLICATION CIRCUIT  
AC INPUT  
VDD/GND  
VSS/-5.1V  
100p  
(10p)  
100p  
(10p)  
C1  
C2  
R6  
R5  
R4  
R3  
R2  
R1  
R7  
10K 10K 10K 10K 10K 10K 10K  
455KHz(32.768KHz)  
ON-OFF  
OFF  
SLT  
S7  
SWING1  
S6  
SPEED  
S5 S4  
TIMER  
S3  
S2  
S1  
SM3015B/D  
R14  
560  
MDO  
E
LIGHT  
GND VDD  
LTO  
LIGHT  
DI  
VSS  
OFF(ON/OFF) OSC1  
-
DOUT  
TIMER  
SPEED  
MODE  
COM1  
COM2  
COM3  
SW1  
OSC2  
BUZ  
+
IR MODULE  
VDD  
LOW  
MED  
STR  
R1  
R9  
0~100  
0~100  
0~100  
5
R1  
6
R1  
D2  
7
SW1  
SW2  
D1  
SHO1  
SHO2  
NC  
SLT  
NC  
1/2  
1
SPT 1/2  
2
4
* NOT  
poss  
RHY LOW MED ST  
R
SPT1  
NOR  
SPT2  
SLP+R SLP+N  
Page 21  
LP  
M1  
M2  
M3  
LIGHT  
L
M
S
SW1 SW2  
R14  
560  
-
C3  
47u  
+
Ω
R9/560  
R10/  
Ω
560  
R11/  
Ω
560  
R12/  
SW1  
SW2  
Ω
R13/  
560  
560  
Ω
* NOTE: 1. D1 and D2 for custom code.  
Code 1: open the diode  
Code 0: use the diode  
2. C3 must be closed to IC as  
possible of PCB layout.  
3. B Type: SLT PIN = NC  
4. Oscillator Option:  
Option Oscillator  
C1,C2  
100p  
10p  
1
2
455KHz  
32.768KHz  
V.2.0 Mar 8, 2002  
SM3015  
S
AM  
HOP Microelectronics Corp.  
REMOTE FAN MCU  
ORDERING INFORMATION  
Logo  
Product No.  
A: A Type  
B: B Type  
C: C Type  
D: D Type  
Empty: 455KHz  
X: 32.768kHz  
A: ON/OFF Key Start-up  
B: SPEED Key Start-up  
M: Memory Function  
N: Non-memory Function  
4: 0.5HR, 1HR, 2HR, 4HR  
8: 1HR, 2HR, 4HR, 8HR  
A: Timer Setting-Ladder Adder  
B: Timer Setting-Shift  
SM3015AX-  
AM4A - FL2ST  
xxx xx  
O: One Operation Wind Mode  
T: Two Operation Wind Mode  
Empty: Three Operation Wind Mode  
F: Four Operation Wind Mode  
S: Tuner Control In Swing2  
F: Tuner Control In Swing1  
N: Non-Tuner Control  
2: Two Swing Head Control  
1: One Swing Head Control  
N: Non-Swing Head Control  
L: Light Function  
N: Non-Light Function  
F: Four Steps For Timer  
T: Three Steps For Timer  
Serial Number  
Date Code  
ESD Protection Mark  
Page 22  
V.2.0 Mar 8, 2002  

SM3015CX 相关器件

型号 制造商 描述 价格 文档
SM3015D SAMHOP REMOTE FAN MCU 获取价格
SM3015DX SAMHOP REMOTE FAN MCU 获取价格
SM3016NSU SINOPWER N-Channel Enhancement Mode MOSFET 获取价格
SM3016NSUC-TRG SINOPWER N-Channel Enhancement Mode MOSFET 获取价格
SM3017NSU SINOPWER N-Channel Enhancement Mode MOSFET 获取价格
SM3017NSUC-TRG SINOPWER N-Channel Enhancement Mode MOSFET 获取价格
SM3020 SEMIKRON 获取价格
SM3020-005-G-D SMI OEM Silicon Pressure Die 获取价格
SM3020-015-G-D SMI OEM Silicon Pressure Die 获取价格
SM3020-030-G-D SMI OEM Silicon Pressure Die 获取价格

SM3015CX 相关文章

  • Bourns 密封通孔金属陶瓷微调电位计产品选型手册(英文版)
    2024-09-20
    6
  • Bourns 精密环境传感器产品选型手册(英文版)
    2024-09-20
    9
  • Bourns POWrTher 负温度系数(NTC)热敏电阻手册 (英文版)
    2024-09-20
    8
  • Bourns GMOV 混合过压保护组件产品选型手册(英文版)
    2024-09-20
    6