K4R761869A-FCS9 [SAMSUNG]

Rambus DRAM, 32MX18, 35ns, CMOS, PBGA92, WBGA-92;
K4R761869A-FCS9
型号: K4R761869A-FCS9
厂家: SAMSUNG    SAMSUNG
描述:

Rambus DRAM, 32MX18, 35ns, CMOS, PBGA92, WBGA-92

动态存储器 内存集成电路
文件: 总20页 (文件大小:158K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Preliminary  
Direct RDRAM™  
K4R521669A  
/K4R761869A for short channel 1066 MHz  
512/576Mbit RDRAM(A-die)  
1M x 16/18bit x 32s banks  
Short channel Direct RDRAMTM  
Version 1.4  
July 2002  
Version 1.4 July 2002  
Preliminary  
Direct RDRAM™  
K4R521669A  
/K4R761869A for short channel 1066 MHz  
Change History  
Version 1.4( July 2002) - Preliminary  
- First Copy ( Version 1.4 is named to unify the version of component and device operation datasheets)  
- Based on the 256/288Mb D-die for Short Channel datasheet version 1.4  
Version 1.4 July 2002  
Preliminary  
Direct RDRAM™  
K4R521669A  
/K4R761869A for short channel 1066 MHz  
Overview  
The Rambus Direct RDRAM™ is a general purpose high-  
performance memory device suitable for use in a broad  
range of applications including computer memory, graphics,  
video, and any other application where high bandwidth and  
low latency are required.  
SAMSUNG 320  
The 512/576-Mbit Direct Rambus DRAMs (RDRAMâ ) are  
extremely high-speed CMOS DRAMs organized as 32M  
words by 16 or 18 bits. The use of Rambus Signaling Level  
(RSL) technology permits up to 1066 MHz transfer rates  
while using conventional system and board design technolo-  
gies. Direct RDRAM devices are capable of sustained data  
transfers up to at 0.938ns per two bytes (7.5ns per sixteen  
bytes).  
K4RXXXX69A-Fxxx  
The architecture of the Direct RDRAMs allows the highest  
sustained bandwidth for multiple, simultaneous randomly  
addressed memory transactions. The separate control and  
data buses with independent row and column control yield  
over 95% bus efficiency. The Direct RDRAM's 32 banks  
support up to four simultaneous transactions.  
Figure 1: Direct RDRAM CSP Package  
The 512/576-Mbit Direct RDRAMs are offered in a CSP  
horizontal package suitable for desktop as well as low-  
profile add-in card and mobile applications.  
System oriented features for mobile, graphics and large  
memory systems include power management, byte masking,  
and x18 organization. The two data bits in the x18 organiza-  
tion are general and can be used for additional storage and  
bandwidth or for error correction.  
Key Timing Parameters/Part Numbers  
Speed  
t
Features  
RAC  
I/O  
Bin Freq.  
MHz  
Organization  
Part Number  
(Row  
Access  
Time) ns  
¨ Highest sustained bandwidth per DRAM device  
- 2.1GB/s sustained data transfer rate  
- Separate control and data buses for maximized  
efficiency  
1Mx16x32sa  
1Mx18x32s  
K4R521669A-FbCcS9  
K4R761869A-FCS9  
-CS9  
-CS9  
1066  
1066  
35  
35  
- Separate row and column control buses for  
easy scheduling and highest performance  
- 32 banks: four transactions can take place simul-  
taneously at full bandwidth data rates  
a.32s- 32 banks which use a splitbank architecture.  
b.F- WBGA package.  
¨ Low latency features  
- Write buffer to reduce read latency  
- 3 precharge mechanisms for controller flexibility  
- Interleaved transactions  
c.C- RDRAM core uses normal power self refresh.  
¨ Advanced power management:  
- Multiple low power states allows flexibility in power  
consumption versus time to transition to active state  
- Power-down self-refresh  
¨ Organization: 2kbyte pages and 32 banks, x 16/18  
- x18 organization allows ECC configurations or  
increased storage/bandwidth  
- x16 organization for low cost applications  
¨ Uses Rambus Signaling Level (RSL) for up to 1066MHz  
operation  
Version 1.4 July 2002  
Page 1  
Preliminary  
Direct RDRAM™  
K4R521669A  
/K4R761869A for short channel 1066 MHz  
Pinouts and Definitions  
Center-Bonded Devices  
package are shown in a later section. Refer to Section  
Center-Bonded WBGA Packageon page 18. Note - pin #1  
is at the A1 position.  
These tables shows the pin assignments of the center-bonded  
RDRAM package. The mechanical dimensions of this  
Table 1: Center-Bonded Device (top view)  
V
GND  
V
GND  
V
V
V
V
GND  
V
DD  
DD  
DD  
DD  
DD  
D D  
DD  
10  
9
GND  
V
C M D  
V
G N D  
GNDa  
DQA1  
GNDa  
CTMN  
V
V
G N D  
R Q 5  
GND  
R Q 3  
V
V
GND  
G N D  
V
V
GND  
DD  
D D  
DD  
D D  
DD  
DD  
C M O S  
DD  
8
V
DQA8  
DQA7  
DQA5  
DQA3  
CTM  
RQ7  
RQ1  
DQB1  
DQB3  
DQB5  
DQB7  
DQB8  
V
DD  
D D  
7
6
5
GND  
G N D  
G N D  
DQA6  
SCK  
DQA4  
DQA2  
G N D  
DQA0  
CFM  
G N D  
CFMN  
RQ6  
R Q 4  
G N D  
R Q 2  
RQ0  
DQB0  
GND  
DQB2  
DQB4  
S I O 0  
DQB6  
SIO1  
G N D  
G N D  
GND  
4
V
V
V
V
V
V
G N D  
V
V
D D  
C M O S  
D D  
DDa  
R E F  
D D  
D D  
DD  
3
2
V
GND  
G N D  
V
G N D  
G N D  
GND  
GND  
GND  
V
DD  
D D  
DD  
1
A
B
C
D
E
F
G
H
J
K
L
M
N
P
R
S
T
U
ROW  
COL  
SAMSUNG 320  
K4RXXXX69A-Fxxx  
Top View  
Chip  
The pin #1(ROW 1, COL A) is located at the  
A1 position on the top side and the A1 position  
is marked by the marker .  
Version 1.4 July 2002  
Page 2  
Preliminary  
Direct RDRAM™  
K4R521669A  
/K4R761869A for short channel 1066 MHz  
Table 2: Pin Description  
# Pins  
center  
Signal  
I/O  
Type  
Description  
Serial input/output. Pins for reading from and writing to the control regis-  
ters using a serial access protocol. Also used for power management.  
a
SIO1,SIO0  
I/O  
CMOS  
CMOS  
CMOS  
2
Command input. Pins used in conjunction with SIO0 and SIO1 for reading  
from and writing to the control registers. Also used for power manage-  
ment.  
a
a
CMD  
SCK  
I
I
1
1
Serial clock input. Clock source used for reading from and writing to the  
control registers  
V
24  
1
Supply voltage for the RDRAM core and interface logic.  
Supply voltage for the RDRAM analog circuitry.  
Supply voltage for CMOS input/output pins.  
DD  
V
DDa  
V
2
CMOS  
GND  
28  
2
Ground reference for RDRAM core and interface.  
Ground reference for RDRAM analog circuitry.  
GNDa  
Data byte A. Nine pins which carry a byte of read or write data between  
the Channel and the RDRAM. DQA8 is not used (no connection) by  
RDRAMs with a x16 organization.  
b
DQA8..DQA0  
I/O  
RSL  
9
1
Clock from master. Interface clock used for receiving RSL signals from  
the Channel. Positive polarity.  
b
CFM  
I
I
RSL  
Clock from master. Interface clock used for receiving RSL signals from  
the Channel. Negative polarity  
b
CFMN  
RSL  
1
1
1
V
Logic threshold reference voltage for RSL signals  
REF  
Clock to master. Interface clock used for transmitting RSL signals to the  
Channel. Negative polarity.  
b
CTMN  
CTM  
I
I
I
I
RSL  
Clock to master. Interface clock used for transmitting RSL signals to the  
Channel. Positive polarity.  
b
RSL  
1
3
5
RQ7..RQ5 or  
ROW2..ROW0  
Row access control. Three pins containing control and address informa-  
tion for row accesses.  
b
RSL  
RQ4..RQ0 or  
COL4..COL0  
Column access control. Five pins containing control and address informa-  
tion for column accesses.  
b
RSL  
Data byte B. Nine pins which carry a byte of read or write data between  
the Channel and the RDRAM. DQB8 is not used (no connection) by  
RDRAMs with a x16 organization.  
DQB8..  
DQB0  
b
I/O  
RSL  
9
Total pin count per package  
92  
a. All CMOS signals are high-true; a high voltage is a logic one and a low voltage is logic zero.  
b. All RSL signals are low-true; a low voltage is a logic one and a high voltage is logic zero.  
Version 1.4 July 2002  
Page 3  
Preliminary  
Direct RDRAM™  
K4R521669A  
/K4R761869A for short channel 1066 MHz  
RQ7..RQ5 or  
ROW2..ROW0  
RQ4..RQ0 or  
COL4..COL0  
5
DQB8..DQB0  
9
CTM CTMN SCK,CMD SIO0,SIO1 CFM CFMN  
DQA8..DQA0  
9
3
2
2
RCLK  
RCLK  
1:8 Demux  
1:8 Demux  
TCLK  
RCLK  
6
Packet Decode  
Control Registers  
Packet Decode  
COLC  
ROWR  
11  
ROWA  
9
COLX  
5
COLM  
5
5
5
5
5
5
7
8
8
ROP DR BR  
AV  
R
REFR  
DEVID  
XOP DX BX COP DC BC  
C
MB MA  
Power Modes  
M
S
Match  
Mux  
Match  
Match  
Write  
Buffer  
DM  
Row Decode  
XOP Decode  
PRER  
ACT  
PREX  
Mux  
Mux  
Column Decode & Mask  
PREC  
RD, WR  
DRAM Core  
Sense Amp  
64x72  
64x72 1024x128x144  
64x72  
72  
Internal DQB Data Path  
72  
Internal DQA Data Path  
72  
72  
Bank 0  
Bank 1  
Bank 2  
9
9
9
9
Bank 13  
Bank 14  
Bank 15  
9
9
Bank 16  
Bank 17  
Bank 18  
9
9
9
9
Bank 29  
Bank 30  
Bank 31  
Figure 2: 512/576-Mbit (1Mx16/18x32s) Direct RDRAM Block Diagram  
Version 1.4 July 2002  
Page 4  
Preliminary  
Direct RDRAM™  
K4R521669A  
/K4R761869A for short channel 1066 MHz  
amps of the RDRAM. These pins are de-multiplexed into a  
24-bit ROWA (row-activate) or ROWR (row-operation)  
packet.  
General Description  
Figure2 is a block diagram of the 512/576-Mbit Direct  
RDRAM. It consists of two major blocks: a coreblock  
built from banks and sense amps similar to those found in  
other types of DRAM, and a Direct Rambus interface block  
which permits an external controller to access this core at up  
to 2.1GB/s.  
COL Pins: The principle use of these five pins is to  
manage the transfer of data between the DQA/DQB pins and  
the sense amps of the RDRAM. These pins are de-multi-  
plexed into a 23-bit COLC (column-operation) packet and  
either a 17-bit COLM (mask) packet or a 17-bit COLX  
(extended-operation) packet.  
Control Registers: The CMD, SCK, SIO0, and SIO1  
pins appear in the upper center of Figure2. They are used to  
write and read a block of control registers. These registers  
supply the RDRAM configuration information to a  
controller and they select the operating modes of the device.  
The REFR value is used for tracking the last refreshed row.  
Most importantly, the five bit DEVID specifies the device  
address of the RDRAM on the Channel.  
ACT Command: An ACT (activate) command from an  
ROWA packet causes one of the 1024 rows of the selected  
bank to be loaded to its associated sense amps (two 512  
bytes sense amps for DQA and two for DQB).  
PRER Command:A PRER (precharge) command from  
an ROWR packet causes the selected bank to release its two  
associated sense amps, permitting a different row in that  
bank to be activated, or permitting adjacent banks to be acti-  
vated.  
Clocking: The CTM and CTMN pins (Clock-To-Master)  
generate TCLK (Transmit Clock), the internal clock used to  
transmit read data. The CFM and CFMN pins (Clock-From-  
Master) generate RCLK (Receive Clock), the internal clock  
signal used to receive write data and to receive the ROW and  
COL pins.  
RD Command: The RD (read) command causes one of  
the 128 dualocts of one of the sense amps to be transmitted  
on the DQA/DQB pins of the Channel.  
DQA,DQB Pins: These 16/18 pins carry read (Q) and  
write (D) data across the Channel. They are multiplexed/de-  
multiplexed from/to two 64/72-bit data paths (running at  
one-eighth the data frequency) inside the RDRAM.  
WR Command: The WR (write) command causes a  
dualoct received from the DQA/DQB data pins of the  
Channel to be loaded into the write buffer. There is also  
space in the write buffer for the BC bank address and C  
column address information. The data in the write buffer is  
automatically retired (written with optional bytemask) to one  
of the 128 dualocts of one of the sense amps during a subse-  
quent COP command. A retire can take place during a RD,  
WR, or NOCOP to another device, or during a WR or  
NOCOP to the same device. The write buffer will not retire  
during a RD to the same device. The write buffer reduces the  
delay needed for the internal DQA/DQB data path turn-  
around.  
Banks: The 64Mbyte core of the RDRAM is divided into  
thirty two 2Mbyte banks, each organized as 1024 rows, with  
each row containing 128 dualocts, and each dualoct  
containing 16/18 bytes. A dualoct is the smallest unit of data  
that can be addressed.  
Sense Amps: The RDRAM contains 34 sense amps. Each  
sense amp consists of 1kbyte of fast storage (512 bytes for  
DQA and 512 bytes for DQB) and can hold one-half of one  
row of one bank of the RDRAM. The sense amp may hold  
any of the 2048 half-rows of an associated bank. However,  
each sense amp is shared between two adjacent banks of the  
RDRAM (except for sense amps 0, 15, 16, and 31). This  
introduces the restriction that adjacent banks may not be  
simultaneously accessed.  
PREC Precharge: The PREC, RDA and WRA  
commands are similar to NOCOP, RD and WR, except that a  
precharge operation is performed at the end of the column  
operation. These commands provide a second mechanism  
for performing precharge.  
PREX Precharge: After a RD command, or after a WR  
command with no byte masking (M=0), a COLX packet may  
be used to specify an extended operation (XOP). The most  
important XOP command is PREX. This command provides  
a third mechanism for performing precharge.  
RQ Pins: These pins carry control and address informa-  
tion. They are broken into two groups. RQ7..RQ5 are also  
called ROW2..ROW0, and are used primarily for controlling  
row accesses. RQ4..RQ0 are also called COL4..COL0, and  
are used primarily for controlling column accesses.  
ROW Pins: The principle use of these three pins is to  
manage the transfer of data between the banks and the sense  
Version 1.4 July 2002  
Page 5  
Preliminary  
Direct RDRAM™  
K4R521669A  
/K4R761869A for short channel 1066 MHz  
The AV (ROWA/ROWR packet selection) bit distinguishes  
between the two packet types. Both the ROWA and ROWR  
packet provide a five bit device address and a five bit bank  
address. An ROWA packet uses the remaining bits to  
specify a nine bit row address, and the ROWR packet uses  
the remaining bits for an eleven bit opcode field. Note the  
use of the RsvXnotation to reserve bits for future address  
field extension.  
Packet Format  
Figure3 shows the formats of the ROWA and ROWR  
packets on the ROW pins. Table3 describes the fields which  
comprise these packets. DR4T and DR4F bits are encoded to  
contain both the DR4 device address bit and a framing bit  
which allows the ROWA or ROWR packet to be recognized  
by the RDRAM.  
Table 3: Field Description for ROWA Packet and ROWR Packet  
Description  
Field  
DR4T,DR4F  
DR3..DR0  
BR4..BR0  
AV  
Bits for framing (recognizing) a ROWA or ROWR packet. Also encodes highest device address bit.  
Device address for ROWA or ROWR packet.  
Bank address for ROWA or ROWR packet. RsvB denotes bits ignored by the RDRAM.  
Selects between ROWA packet (AV=1) and ROWR packet (AV=0).  
R9..R0  
Row address for ROWA packet. RsvR denotes bits ignored by the RDRAM.  
Opcode field for ROWR packet. Specifies precharge, refresh, and power management functions.  
ROP10..ROP0  
Figure3 also shows the formats of the COLC, COLM, and  
COLX packets on the COL pins. Table4 describes the fields  
which comprise these packets.  
The remaining 17 bits are interpreted as a COLM (M=1) or  
COLX (M=0) packet. A COLM packet is used for a COLC  
write command which needs bytemask control. The COLM  
packet is associated with the COLC packet from at least  
The COLC packet uses the S (Start) bit for framing. A  
COLM or COLX packet is aligned with this COLC packet,  
and is also framed by the S bit.  
t
earlier. A COLX packet may be used to specify an  
RTR  
independent precharge command. It contains a five bit  
device address, a five bit bank address, and a five bit opcode.  
The COLX packet may also be used to specify some house-  
keeping and power management commands. The COLX  
packet is framed within a COLC packet but is not otherwise  
associated with any other packet.  
The 23 bit COLC packet has a five bit device address, a five  
bit bank address, a seven bit column address, and a four bit  
opcode. The COLC packet specifies a read or write  
command, as well as some power management commands.  
Table 4: Field Description for COLC Packet, COLM Packet, and COLX Packet  
Field  
Description  
S
Bit for framing (recognizing) a COLC packet, and indirectly for framing COLM and COLX packets.  
Device address for COLC packet.  
DC4..DC0  
BC4..BC0  
C6..C0  
Bank address for COLC packet. RsvB denotes bits reserved for future extension (controller drives 0 ’ s).  
Column address for COLC packet. RsvC denotes bits ignored by the RDRAM.  
Opcode field for COLC packet. Specifies read, write, precharge, and power management functions.  
Selects between COLM packet (M=1) and COLX packet (M=0).  
COP3..COP0  
M
MA7..MA0  
MB7..MB0  
DX4..DX0  
BX4..BX0  
XOP4..XOP0  
Bytemask write control bits. 1=write, 0=no-write. MA0 controls the earliest byte on DQA8..0.  
Bytemask write control bits. 1=write, 0=no-write. MB0 controls the earliest byte on DQB8..0.  
Device address for COLX packet.  
Bank address for COLX packet. RsvB denotes bits reserved for future extension (controller drives 0’ s).  
Opcode field for COLX packet. Specifies precharge, I control, and power management functions.  
OL  
Version 1.4 July 2002  
Page 6  
Preliminary  
Direct RDRAM™  
K4R521669A  
/K4R761869A for short channel 1066 MHz  
T0  
T1  
T2  
T3  
T8  
T9  
T10  
T11  
CTM/CFM  
CTM/CFM  
ROW2 DR4T DR2 BR0 BR3 RsvR R8  
R5  
R4  
R3  
R2  
R1  
R0  
ROW2 DR4T DR2 BR0 BR3 ROP10 ROP8 ROP5 ROP2  
ROW1  
ROW0  
DR1 BR1 BR4 R9  
R7  
ROW1  
ROW0  
DR1 BR1 BR4 ROP9 ROP7 ROP4 ROP1  
DR0 BR2 RsvB AV=0 ROP6 ROP3 ROP0  
DR4F  
DR3  
DR4F  
DR3  
DR0 BR2 RsvB AV=1 R6  
ROWA Packet  
ROWR Packet  
T0  
T1  
T2  
T3  
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
1 4 1 5  
0
1
2
3
4
5
6
7
8
9
1 0  
1 1 12  
13  
CTM/CFM  
CTM/CFM  
ROW2  
DC4 S=1  
DC3  
C6  
C5  
C4  
C3  
ACT a0  
WR b1  
PRER c0  
COL4  
COL3  
COL2  
COL1  
COL0  
..ROW0  
t
PACKET  
MSK (b1) PREX d0  
COL4  
..COL0  
DC2 COP1  
DC1 COP0  
DC0 COP2  
RsvB BC2 C2  
BC4 BC1 C1  
DQA8..0  
DQB8..0  
COP3 BC3 BC0 C0  
COLC Packet  
T8  
T9  
T10  
T11  
T12  
T13  
T14  
T15  
CTM/CFM  
CTM/CFM  
COL4  
COL3  
COL2  
COL1  
S=1a MA7 MA5 MA3 MA1  
M=1 MA6 MA4 MA2 MA0  
MB7 MB4 MB1  
COL4  
COL3  
COL2  
COL1  
COL0  
S=1b DX4 XOP4 RsvB BX1  
M=0 DX3 XOP3 BX4 BX0  
DX2 XOP2 BX3  
MB6 MB3 MB0  
DX1 XOP1 BX2  
COL0  
MB5 MB2  
DX0 XOP0  
b
a
The COLX is aligned  
The COLM is associated with a  
previous COLC, and is aligned  
with the present COLC, indicated  
by the Start bit (S=1) position.  
with the present COLC,  
COLM Packet  
COLX Packet  
indicated by the Start  
bit (S=1) position.  
Figure 3: Packet Formats  
Version 1.4 July 2002  
Page 7  
Preliminary  
Direct RDRAM™  
K4R521669A  
/K4R761869A for short channel 1066 MHz  
broadcast operation is indicated when both bits are set.  
Broadcast operation would typically be used for refresh and  
power management commands. If the device is selected, the  
DM (DeviceMatch) signal is asserted and an ACT or ROP  
command is performed.  
Field Encoding Summary  
Table5 shows how the six device address bits are decoded  
for the ROWA and ROWR packets. The DR4T and DR4F  
encoding merges a fifth device bit with a framing bit. When  
neither bit is asserted, the device is not selected. Note that a  
Table 5: Device Field Encodings for ROWA Packet and ROWR Packet  
DR4T  
DR4F  
Device Selection  
Device Match signal (DM)  
1
0
1
0
1
1
0
0
All devices (broadcast)  
One device selected  
One device selected  
No packet present  
DM is set to 1  
DM is set to 1 if {DEVID4..DEVID0} == {0,DR3..DR0} else DM is set to 0  
DM is set to 1 if {DEVID4..DEVID0} == {1,DR3..DR0} else DM is set to 0  
DM is set to 0  
Table6 shows the encodings of the remaining fields of the  
ROWA and ROWR packets. An ROWA packet is specified  
by asserting the AV bit. This causes the specified row of the  
specified bank of this device to be loaded into the associated  
sense amps.  
row address comes from an internal register REFR, and  
REFR is incremented at the largest bank address. The REFP  
(refresh-precharge) command is identical to a PRER  
command.  
The NAPR, NAPRC, PDNR, ATTN, and RLXR commands  
are used for managing the power dissipation of the RDRAM  
and are described in more detail in Power State Manage-  
menton page50. The TCEN and TCAL commands are  
used to adjust the output driver slew rate and they are  
described in more detail in Current and Temperature  
Controlon page56.  
An ROWR packet is specified when AV is not asserted. An  
11 bit opcode field encodes a command for one of the banks  
of this device. The PRER command causes a bank and its  
two associated sense amps to precharge, so another row or  
an adjacent bank may be activated. The REFA (refresh-acti-  
vate) command is similar to the ACT command, except the  
Table 6: ROWA Packet and ROWR Packet Field Encodings  
ROP10..ROP0 Field  
a
DM  
AV  
Name  
Command Description  
10  
9
8
7
6
5
4
3
2:0  
0
-
-
-
-
-
-
-
-
-
---  
-
No operation.  
1
1
1
0
Row address  
ACT  
Activate row R9..R0 of bank BR4..BR0 of device and move device to ATTNb.  
Precharge bank BR4..BR0 of this device.  
1
0
1
0
0
0
0
1
0
1
xc  
0
x
0
x
x
000 PRER  
000 REFA  
Refresh (activate) row REFR8..REFR0 of bank BR4..BR0 of device.  
Increment REFR if BR4..BR0 = 11111 (see Figure52).  
1
0
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
1
x
x
x
x
x
0
0
0
0
x
x
x
x
x
0
0
0
1
0
0
0
x
x
0
0
0
0
0
0
0
x
x
0
0
0
1
0
0
0
x
x
0
0
0
0
0
1
1
x
x
0
0
0
0
1
0
1
x
x
0
0
0
x
x
x
x
0
1
x
x
0
000 REFP  
000 PDNR  
000 NAPR  
Precharge bank BR4..BR0 of this device after REFA (see Figure52).  
Move this device into the powerdown (PDN) power state (see Figure49).  
Move this device into the nap (NAP) power state (see Figure49).  
000 NAPRC Move this device into the nap (NAP) power state conditionally  
000 ATTNb  
000 RLXR  
001 TCAL  
010 TCEN  
Move this device into the attention (ATTN) power state (see Figure47).  
Move this device into the standby (STBY) power state (see Figure48).  
Temperature calibrate this device (see Figure55).  
Temperature calibrate/enable this device (see Figure55).  
000 NOROP No operation.  
a. The DM (Device Match signal) value is determined by the DR4T,DR4F, DR3..DR0 field of the ROWA and ROWR packets. See Table5.  
b. The ATTN command does not cause a RLX-to-ATTN transition for a broadcast operation (DR4T/DR4F=1/1).  
c. An xentry indicates which commands may be combined. For instance, the three commands PRER/NAPRC/RLXR may be specified in one ROP va lue (011000111000).  
Version 1.4 July 2002  
Page 8  
Preliminary  
Direct RDRAM™  
K4R521669A  
/K4R761869A for short channel 1066 MHz  
Table7 shows the COP field encoding. The device must be  
in the ATTN power state in order to receive COLC packets.  
The COLC packet is used primarily to specify RD (read) and  
WR (write) commands. Retire operations (moving data from  
the write buffer to a sense amp) happen automatically. See  
Figure18 for a more detailed description.  
The COLC packet can also specify a PREC command,  
which precharges a bank and its associated sense amps. The  
RDA/WRA commands are equivalent to combining RD/WR  
with a PREC. RLXC (relax) performs a power mode transi-  
tion. See Power State Managementon page50.  
Table 7: COLC Packet Field Encodings  
DC4.. DC0  
(select device)  
S
COP3..0 Name  
Command Description  
a
0
----  
-----  
-
-
No operation.  
Retire write buffer of this device.  
1
1
1
1
1
1
1
1
1
1
/= (DEVID4 ..0)  
== (DEVID4 ..0)  
== (DEVID4 ..0)  
== (DEVID4 ..0)  
== (DEVID4 ..0)  
== (DEVID4 ..0)  
== (DEVID4 ..0)  
== (DEVID4 ..0)  
== (DEVID4 ..0)  
== (DEVID4 ..0)  
-----  
x000b  
x001  
x010  
x011  
x100  
x101  
x110  
x111  
1xxx  
NOCOP Retire write buffer of this device.  
WR  
Retire write buffer of this device, then write column C6..C0 of bank BC4..BC0 to write buffer.  
RSRV  
RD  
Reserved, no operation.  
Read column C6..C0 of bank BC4..BC0 of this device.  
Retire write buffer of this device, then precharge bank BC4..BC0 (see Figure15).  
Same as WR, but precharge bank BC4..BC0 after write buffer (with new data) is retired.  
Reserved, no operation.  
PREC  
WRA  
RSRV  
RDA  
RLXC  
Same as RD, but precharge bank BC4..BC0 afterward.  
Move this device into the standby (STBY) power state (see Figure48).  
a. /=means not equal, ==means equal.  
b. Anxentry indicates which commands may be combined. For instance, the two commands WR/RLXC may be specified in one COP value (1001) .  
Table8 shows the COLM and COLX field encodings. The  
M bit is asserted to specify a COLM packet with two 8 bit  
bytemask fields MA and MB. If the M bit is not asserted, an  
COLX is specified. It has device and bank address fields,  
and an opcode field. The primary use of the COLX packet is  
to permit an independent PREX (precharge) command to be  
specified without consuming control bandwidth on the ROW  
pins. It is also used for the CAL(calibrate) and SAM (sam-  
ple) current control commands (see Current and Tempera-  
ture Controlon page56), and for the RLXX power mode  
command (see Power State Managementon page50).  
Table 8: COLM Packet and COLX Packet Field Encodings  
DX4 .. DX0  
(selects device)  
M
XOP4..0  
Name  
MSK  
Command Description  
1
----  
-
-
MB/MA bytemasks used by WR/WRA.  
0
0
0
0
0
0
0
/= (DEVID4 ..0)  
== (DEVID4 ..0)  
== (DEVID4 ..0)  
== (DEVID4 ..0)  
== (DEVID4 ..0)  
== (DEVID4 ..0)  
== (DEVID4 ..0)  
-
No operation.  
00000  
1xxx0a  
x10x0  
x11x0  
xxx10  
xxxx1  
NOXOP  
PREX  
CAL  
No operation.  
Precharge bank BX3..BX0 of this device (see Figure15).  
Calibrate (drive) IOL current for this device (see Figure54).  
Calibrate (drive) and Sample ( update) IOL current for this device (see Figure54).  
Move this device into the standby (STBY) power state (see Figure48).  
Reserved, no operation.  
CAL/SAM  
RLXX  
RSRV  
a. An xentry indicates which commands may be combined. For instance, the two commands PREX/RLXX may be specified in one XOP value (100 10).  
Version 1.4 July 2002  
Page 9  
Preliminary  
Direct RDRAM™  
K4R521669A  
/K4R761869A for short channel 1066 MHz  
Electrical Conditions  
Table 9: Electrical Conditions  
Symbol  
Parameter and Conditions  
Junction temperature under bias  
Min  
Max  
Unit  
TJ  
-
100  
2.50 + 0.13  
2.0  
°C  
V
VDD, VDDA  
Supply voltage  
2.50 - 0.13  
VDD,N, VDDA ,N  
vDD,N, vDDA,N  
Supply voltage droop (DC) during NAP interval (tNLIMIT  
Supply voltage ripple (AC) during NAP interval (tNLIMIT  
)
)
-
%
%
-2.0  
2.0  
a
VCMOS  
Supply voltage for CMOS pins (2.5V controllers)  
Supply voltage for CMOS pins (1.8V controllers)  
VDD  
1.80 - 0.1  
VDD  
1.80 + 0.2  
V
V
VREF  
Reference voltage  
1.40 - 0.2  
VREF - 0.5  
VREF + 0.2  
0.67  
1.40 + 0.2  
VREF - 0.2  
VREF + 0.5  
1.00  
V
V
V
-
VDIL  
RSL data input - low voltage @ tCYCLE =1.875ns  
RSL data input - high voltageb @ tCYCLE =1.875ns  
VDIH  
RDA  
RSL data asymmetry : RDA = (VDIH - VREF ) / (VREF - VDIL  
RSL clock input - common mode VCM = (VCIH+VCIL) /2  
)
VCM  
1.3  
1.8  
V
V
V
V
V
VCIS,CTM  
VCIS,CFM  
VIL,CMOS  
VIH,CMOS  
RSL clock input swing: VCIS = VCIH - VCIL (CTM,CTMN pins).  
RSL clock input swing: VCIS = VCIH - VCIL (CFM,CFMN pins).  
CMOS input low voltage  
0.35  
1.00  
0.225  
1.00  
- 0.3c  
VCMOS/2 - 0.25  
VCMOS+0.3d  
CMOS input high voltage  
VCMOS/2 + 0.25  
a. VCMOS must remain on as long as VDD is applied and cannot be turned off.  
b. VDIH is typically equal to VTERM (1.8V±0.1V) under DC conditions in a system.  
c. Voltage undershoot is limited to -0.7V for a duration of less than 5ns.  
d. Voltage overshoot is limited toVCMOS +0.7V for a duration of less than 5ns  
Version 1.4 July 2002  
Page 10  
Preliminary  
Direct RDRAM™  
K4R521669A  
/K4R761869A for short channel 1066 MHz  
Electrical Characteristics  
Table 10: Electrical Characteristics  
Symbol  
Parameter and Conditions  
Junction-to-Case thermal resistance  
Min  
Max  
Unit  
QJC  
-
0.5  
10  
°C/Watt  
mA  
IREF  
IOH  
VREF current @ VREF,MAX  
-10  
RSL output high current @ (0£VOUT£VDD  
)
-10  
10  
mA  
a
IALL  
DIOL  
rOUT  
RSL IOL current @ tCYCLE = 1.875ns VOL = 0.9V, VDD,MIN , TJ,MAX  
RSL IOL current resolution step  
30.0  
90.0  
2.0  
-
mA  
mA  
W
-
150  
Dynamic output impedance @ VOL= 0.9V  
IOL,NOM  
RSL IOL current @ VOL = 1.0V b,c@ tCYCLE =1.875ns  
26.6  
30.6  
10.0  
0.3  
-
mA  
mA  
II,CMOS  
CMOS input leakage current @ (0£VI,CMOS£ VCMOS  
)
-10.0  
-
VOL,CMOS  
VOH,CMOS  
CMOS output voltage @ IOL,CMOS= 1.0mA  
V
CMOS output high voltage @ IOH,CMOS= -0.25mA  
VCMOS-0.3  
V
a. This measurement is made in manual current control mode; i.e. with all output device legs sinking current.  
b. This measurement is made in automatic current control mode after at least 64 current control calibration operations to a device and after CCA and  
CCB are initialized to a value of 64. This value applies to all DQA and DQB pins.  
c. This measurement is made in automatic current control mode in a 25W test system with VTERM= 1.714V and VREF= 1.357V and with the ASYMA  
and ASYMB register fields set to 0.  
Version 1.4 July 2002  
Page 11  
Preliminary  
Direct RDRAM™  
K4R521669A  
/K4R761869A for short channel 1066 MHz  
Timing Conditions  
Table 11: Timing Conditions  
Symbol  
tCYCLE  
Parameter  
CTM and CFM cycle times (-1066)  
Min  
Max  
Unit  
Figure(s)  
1.875  
2.5  
ns  
Figure56  
CTM and CFM input rise and fall times. Use the minimum value of  
these parameters during testing.  
tC R, tCF  
tC H, tCL  
tTR  
0.2  
0.5  
ns  
Figure56  
Figure56  
CTM and CFM high and low times  
40%  
60%  
tCYCLE  
tCYCLE  
tCYCLE  
ns  
CTM-CFM differential (MSE/MS=0/0)  
CTM-CFM differential (MSE/MS=1/1)a  
0.0  
0.9  
1.0  
1.0  
Figure43  
Figure56  
tDCW  
Domain crossing window  
-0.1  
0.2  
0.1  
Figure62  
Figure57  
DQA/DQB/ROW/COL input rise/fall times (20% to 80%). Use the  
minimum value of these parameters during testing.@ t CYCLE=1.875ns  
tD R, tDF  
0.65  
tS , tH  
DQA/DQB/ROW/COL-to-CFM set/hold @ t CYCLE=1.875ns  
SIO0, SIO1 input rise and fall times  
0.190b  
-
-
ns  
ns  
ns  
Figure57  
Figure59  
Figure59  
tDR1, tDF1  
tDR2, tDF2  
5.0  
CMD, SCK input rise and fall times  
-
2.0  
SCK cycle time - Serial control register transactions  
SCK cycle time - Power transitions @ t CYCLE=1.875ns  
SCK high and low times @ t CYCLE=1.875ns  
CMD setup time to SCK rising or falling edge c @ t CYCLE=1.875ns  
CMD hold time to SCK rising or falling edged  
SIO0 setup time to SCK falling edge  
1000  
7.5  
4.25  
1.25  
1
-
tCYCLE1  
ns  
Figure59  
-
tCH1 , tCL1  
-
ns  
ns  
Figure59  
Figure59  
Figure59  
Figure59  
Figure59  
Figure50  
Figure60  
Figure50  
Figure50  
Figure49  
Figure54  
Figure54  
Figure50  
Figure49  
Figure48  
Figure47  
Figure52  
tS 1  
-
tH1  
-
ns  
tS 2  
40  
40  
0
-
ns  
tH2  
SIO0 hold time to SCK falling edge  
-
ns  
tS 3  
PDEV setup time on DQA5..0 to SCK rising edge.  
PDEV hold time on DQA5..0 to SCK rising edge.  
ROW2..0, COL4..0 setup time for quiet window  
ROW2..0, COL4..0 hold time for quiet windowd  
Quiet on ROW/COL bits during NAP/PDN entry  
Offset between read data and CC packets (same device)  
Offset between CC packet and read data (same device)  
CTM/CFM stable before NAP/PDN exit  
-
ns  
tH3  
5.5  
-1  
-
ns  
tS 4  
-
tCYCLE  
tCYCLE  
tCYCLE  
tCYCLE  
tCYCLE  
tCYCLE  
tCYCLE  
tCYCLE  
ms  
tH4  
5
-
tNPQ  
4
-
tREADTOCC  
tCCSAMTOREAD  
tC E  
12  
8
-
-
2
-
-
tC D  
CTM/CFM stable after NAP/PDN entry  
100  
7
tFRM  
ROW packet to COL packet ATTN framing delay  
Maximum time in NAP mode  
-
tNLIMIT  
tREF  
tBURST  
tCCTRL  
10.0  
32  
Refresh interval  
ms  
Interval after PDN or NAP (with self-refresh) exit in which all banks  
of the RDRAM must be refreshed at least once.  
200  
ms  
Figure53  
Figure54  
Current control interval  
34 tCYCLE  
100ms  
ms/tCYCLE  
Version 1.4 July 2002  
Page 12  
Preliminary  
Direct RDRAM™  
K4R521669A  
/K4R761869A for short channel 1066 MHz  
Table 11: Timing Conditions  
Symbol  
tTEMP  
Parameter  
Temperature control interval  
Min  
Max  
Unit  
Figure(s)  
100  
ms  
Figure55  
Figure55  
Figure55  
Figure55  
tTCEN  
TCE command to TCAL command  
TCAL command to quiet window  
Quiet window (no read data)  
150  
2
-
tCYCLE  
tCYCLE  
tCYCLE  
tTCAL  
2
-
tTCQUIET  
140  
tPAUSE  
RDRAM delay (no RSL operations allowed)  
200.0  
ms  
page 38  
a. MSE/MS are fields of the SKIP register. For this combination (skip override) the tDCW parameter range is effectively 0.0 to 0.0.  
b. tS,MIN and tH,MIN for other tCYCLE values can be interpolated between or extrapolated from the timings at the 2 specified t  
c. With VIL,CMOS=0.5VCMOS-0.4V and VIH,CMOS=0.5VCMOS+0.4V  
values.  
CYCLE  
d. Effective hold becomes tH4’ =tH4+[PDNXA64tSCYCLE+tPDNXB,MAX]-[PDNX256tSCYCLE  
if [PDNX256tSCYCLE] < [PDNXA64tSCYCLE+tPDNXB,MAX ]. See Figure50.  
]
Version 1.4 July 2002  
Page 13  
Preliminary  
Direct RDRAM™  
K4R521669A  
/K4R761869A for short channel 1066 MHz  
Timing Characteristics  
Table 12: Timing Characteristics  
Symbol  
Parameter  
Min  
Max  
Unit  
Figure(s)  
tQ  
tQ R, tQF  
tQ1  
CTM-to-DQA/DQB output time @ tCYCLE=1.875ns  
DQA/DQB output rise and fall times @ tCYCLE=1.875ns  
SCK(neg)-to-SIO0 delay @ CLOAD,MAX = 20pF (SD read data valid).  
SCK(pos)-to-SIO0 delay @ CLOAD,MAX = 20pF (SD read data hold).  
SIOOUT rise/fall @ CLOAD,MAX = 20pF  
SIO0-to-SIO1 or SIO1-to-SIO0 delay @ CLOAD,MAX = 20pF  
NAP exit delay - phase A  
-0.240a  
+0.240a  
ns  
ns  
Figure58  
Figure58  
Figure61  
Figure61  
Figure61  
Figure61  
Figure50  
Figure50  
Figure50  
Figure50  
Figure48  
Figure48  
Figure49  
Figure49  
0.2  
-
0.45  
10  
-
ns  
tH R  
2
-
ns  
tQR1, tQF1  
tPROP1  
tNAPXA  
tNAPXB  
tPDNXA  
tPDNXB  
tAS  
12  
20  
50  
40  
4
ns  
-
ns  
-
ns  
NAP exit delay - phase B  
-
ns  
PDN exit delay - phase A  
-
ms  
PDN exit delay - phase B  
-
9000  
1
tCYCLE  
tCYCLE  
tCYCLE  
tCYCLE  
tCYCLE  
ATTN-to-STBY power state delay  
-
tSA  
STBY-to-ATTN power state delay  
-
0
tASN  
ATTN/STBY-to-NAP power state delay  
ATTN/STBY-to-PDN power state delay  
-
8
tASP  
-
8
a. tQ,MIN and tQ,MAX for other tCYCLE values can be interpolated between or extrapolated from the timings at the 3 specified tCYCLE values.  
Version 1.4 July 2002  
Page 14  
Preliminary  
Direct RDRAM™  
K4R521669A  
/K4R761869A for short channel 1066 MHz  
Timing Parameters  
Table 13: Timing Parameter Summary  
Min  
-35  
Parameter  
Description  
Max  
Units  
Figure(s)  
-1066  
Row Cycle time of RDRAM banks -the interval between ROWA packets with ACT commands  
to the same bank.  
Figure16  
Figure17  
tRC  
tRAS  
tRP  
32  
22  
10  
8
-
tCYCLE  
RAS-asserted time of RDRAM bank - the interval between ROWA packet with ACT command  
and next ROWR packet with PRERa command to the same bank.  
Figure16  
Figure17  
64msb tCYCLE  
Row Precharge time of RDRAM banks - the interval between ROWR packet with PRERa com-  
mand and next ROWA packet with ACT command to the same bank.  
Figure16  
Figure17  
-
-
-
tCYCLE  
tCYCLE  
tCYCLE  
Precharge-to-precharge time of RDRAM device - the interval between successive ROWR  
packets with PRERa commands to any banks of the same device.  
tPP  
Figure13  
Figure14  
RAS-to-RAS time of RDRAM device - the interval between successive ROWA packets with  
ACT commands to any banks of the same device.  
tRR  
8
RAS-to-CAS Delay - the interval from ROWA packet with ACT command to COLC packet  
with RD or WR command). Note - the RAS-to-CAS delay seen by the RDRAM core (tRCD-C  
is equal to tRCD-C = 1 + tRCD because of differences in the row and column paths through the  
RDRAM interface.  
)
Figure16  
Figure17  
tRCD  
9
-
tCYCLE  
CAS Access delay - the interval from RD command to Q read data. The equation for tCAC is  
given in the TPARM register in Figure40.  
Figure5  
Figure40  
tCAC  
tCWD  
tCC  
9
6
4
4
8
12  
6
-
tCYCLE  
tCYCLE  
tCYCLE  
tCYCLE  
tCYCLE  
CAS Write Delay (interval from WR command to D write data.  
Figure5  
Figure16  
Figure17  
CAS-to-CAS time of RDRAM bank - the interval between successive COLC commands).  
Length of ROWA, ROWR, COLC, COLM or COLX packet.  
tPACKET  
tRTR  
4
-
Figure3  
Figure18  
Interval from COLC packet with WR command to COLC packet which causes retire, and to  
COLM packet with bytemask.  
The interval (offset) from COLC packet with RDA command, or from COLC packet with retire  
command (after WRA automatic precharge), or from COLC packet with PREC command, or  
from COLX packet with PREX command to the equivalent ROWR packet with PRER. The  
equation for tOFFP is given in the TPARM register in Figure40.  
Figure15  
Figure40  
tOFFP  
4
4
tCYCLE  
tRDP  
tRTP  
Interval from last COLC packet with RD command to ROWR packet with PRER.  
5
5
-
-
tCYCLE  
tCYCLE  
Figure16  
Figure17  
Interval from last COLC packet with automatic retire command to ROWR packet with PRER.  
a. Or equivalent PREC or PREX command. See Figure15.  
b. This is a constraint imposed by the core, and is therefore in units of ms rather than tCYCLE  
.
Version 1.4 July 2002  
Page 15  
Preliminary  
Direct RDRAM™  
K4R521669A  
/K4R761869A for short channel 1066 MHz  
Absolute Maximum Ratings  
Table 14: Absolute Maximum Ratings  
Symbol  
Parameter  
Min  
Max  
Unit  
VI,ABS  
VDD,ABS , VDDA,ABS  
TSTORE  
Voltage applied to any RSL or CMOS pin with respect to Gnd  
Voltage on VDD and VDDA with respect to Gnd  
Storage temperature  
- 0.3  
- 0.5  
- 50  
0
VDD+0.3  
VDD+1.0  
100  
V
V
°C  
°C  
TMIN  
Minimum operation temperature  
Note*  
Note*) Component : refer to TJ,QJC RIMM: refre to TPLATE, MAX  
I
- Supply Current Profile  
DD  
Table 15: Supply Current Profile  
Max  
(1066MHz,  
-35)  
a
I
value  
RDRAM Power State and Steady-State Transaction Rates  
Min  
Unit  
D D  
IDD,PDN  
IDD,NAP  
Device in PDN, self-refresh enabled and INIT.LSR=0.  
Device in NAP.  
-
-
TBD  
TBD  
mA  
mA  
Device in STBY. This is the average for a device in STBY with (1) no packets on the  
Channel, and (2) with packets sent to other devices.  
IDD,STBY  
-
-
-
TBD  
TBD  
TBD  
mA  
mA  
mA  
IDD,REFRESH  
IDD,ATTN  
Device in STBY and refreshing rows at the tREF,MAX period.  
Device in ATTN. This is the average for a device in ATTN with (1) no packets on the  
Channel, and (2) with packets sent to other devices.  
Device in ATTN. ACT command every 8• t CYCLE , PRE command every 8• t CYCLE  
WR command every 4tCYCLE, and data is 1100..1100  
,
,
IDD,ATTN-W  
-
-
TBD  
TBD  
mA  
mA  
Device in ATTN. ACT command every 8• t CYCLE , PRE command every 8tCYCLE  
RD command every 4tCYCLE, and data is 1111..1111b  
IDD,ATTN-R  
a. CMOS interface consumes power in all power states.  
b. This does not include the IOL sink current. The RDRAM dissipates IOLVOL in each output driver when a logic one is driven.  
Table 16: Supply Current at Initialization  
Symbol  
Parameter  
Allowed Range of t  
V
Min  
Max  
Unit  
CYCLE  
DD  
VDD,MIN  
VDD,MIN  
IDD,PWRUP,D  
IDD,SETR,D  
IDD from power -on to SETR  
IDD from SETR to CLRR  
1.875ns to 2.5ns  
1.875ns to 2.5ns  
-
-
TBD  
TBD  
mA  
mA  
Version 1.4 July 2002  
Page 16  
Preliminary  
Direct RDRAM™  
K4R521669A  
/K4R761869A for short channel 1066 MHz  
Capacitance and Inductance  
Table 17: RSL Pin Parasitics  
Symbol  
Parameter and Conditions - RSL pins  
RSL effective input inductance @ tCYCLE=1.875ns  
Min  
Max  
4.0  
0.2  
0.6  
1.0  
2.4  
0.1  
Unit  
nH  
nH  
nH  
nH  
pF  
Figure  
L
L
-
Figure 63  
I
Mutual inductance between any DQA or DQB RSL signals.  
Mutual inductance between any ROW or COL RSL signals.  
-
-
Figure 63  
12  
DL  
Difference in L value between any RSL pins of a single device.  
-
Figure 63  
Figure 63  
Figure 63  
I
I
a
C
C
RSL effective input capacitance @ tCYCLE=1.875ns  
2.0  
-
I
Mutual capacitance between any RSL signals.  
pF  
12  
Difference in C value between average of {CTM, CTMN,  
I
DC  
-
0.06  
15  
pF  
Figure 63  
Figure 63  
I
CFM, CFMN} and any RSL pins of a single device.  
R
RSL effective input resistance @ tCYCLE=1.875ns  
4
W
I
a. This value is a combination of the device IO circuitry and package capacitances measured at VDD=2.5V and f=400MHz with pin biased at 1.4V.  
Table 18: CMOS Pin Parasitics  
Symbol  
Parameter and Conditions - CMOS pins  
CMOS effective input inductance  
CMOS effective input capacitance (SCK,CMD)  
Min  
Max  
Unit  
Figure  
L
8.0  
2.1  
7.0  
nH  
pF  
pF  
I ,CMOS  
a
C
C
1.7  
-
Figure 63  
I ,CMOS  
I ,CMOS,SIO  
a
CMOS effective input capacitance (SIO1, SIO0)  
a. This value is a combination of the device IO circuitry and package capacitances.  
Version 1.4 July 2002  
Page 17  
Preliminary  
Direct RDRAM™  
K4R521669A  
/K4R761869A for short channel 1066 MHz  
Center-Bonded WBGA Package  
(92balls)  
Figure4 shows the form and dimensions of the recom-  
mended package for the 92balls center-bonded WBGA  
device class.  
D
Bottom  
A
B
C
D
E
F
G
H
J
K
L
M
N
P
R
S
T
U
Bottom  
Top  
1
2
3
4
A
5
6
7
8
e2  
9
10  
d
e1  
Bottom  
E
E1  
Figure 4: Center-Bonded WBGA Package  
Table19 lists the numerical values corresponding to dimen-  
sions shown in Figure4.  
Table 19: Center-Bonded WBGA Package Dimensions  
Symbol  
Parameter  
Min.  
Max.  
Unit  
e1  
e2  
A
Ball pitch (x-axis)  
0.80  
0.80  
13.3  
15.0  
0.98  
0.30  
0.40  
0.80  
0.80  
13.5  
15.2  
1.08  
0.40  
0.50  
mm  
mm  
mm  
mm  
mm  
mm  
mm  
Ball pitch (y-axis)  
Package body length  
Package body width  
D
E
Package total thickness  
Ball height  
E1  
d
Ball diameter  
Version 1.4 July 2002  
Page 18  

相关型号:

K4R761869A-FCT9

576Mbit RDRAM (A-die) 1M x 18bit x 32s banks Direct RDRAMTM
SAMSUNG

K4R761869A-FCT90

Rambus DRAM, 32MX18, CMOS, PBGA92, WBGA-92
SAMSUNG

K4R761869A-GCM8

576Mbit RDRAM (A-die) 1M x 18bit x 32s banks Direct RDRAMTM
SAMSUNG

K4R761869A-GCM80

Rambus DRAM, 32MX18, CMOS, PBGA92, LEAD FREE, WBGA-92
SAMSUNG

K4R761869A-GCN1

576Mbit RDRAM (A-die) 1M x 18bit x 32s banks Direct RDRAMTM
SAMSUNG

K4R761869A-GCN10

Rambus DRAM, 32MX18, CMOS, PBGA92, LEAD FREE, WBGA-92
SAMSUNG

K4R761869A-GCT9

576Mbit RDRAM (A-die) 1M x 18bit x 32s banks Direct RDRAMTM
SAMSUNG

K4R881869

288Mbit RDRAM 512K x 18 bit x 2*16 Dependent Banks Direct RDRAMTM
SAMSUNG

K4R881869A-FCT9

Rambus DRAM, 16MX18, CMOS, PBGA92, WBGA-92
SAMSUNG

K4R881869D

256/288Mbit RDRAM(D-die)
SAMSUNG

K4R881869D-FCK8

Rambus DRAM, 16MX18, 45ns, CMOS, PBGA92, WBGA-92
SAMSUNG

K4R881869D-FCK80

Rambus DRAM, 16MX18, CMOS, PBGA92, WBGA-92
SAMSUNG