K4X56163PG-FGCA [SAMSUNG]

DDR DRAM, 16MX16, 6ns, CMOS, PBGA60,;
K4X56163PG-FGCA
型号: K4X56163PG-FGCA
厂家: SAMSUNG    SAMSUNG
描述:

DDR DRAM, 16MX16, 6ns, CMOS, PBGA60,

时钟 动态存储器 双倍数据速率 内存集成电路
文件: 总23页 (文件大小:217K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
K4X56163PG - L(F)E/G  
Mobile-DDR SDRAM  
16M x16 Mobile-DDR SDRAM  
FEATURES  
• 1.8V power supply, 1.8V I/O power  
• Double-data-rate architecture; two data transfers per clock cycle  
• Bidirectional data strobe(DQS)  
• Four banks operation  
• Differential clock inputs(CK and CK)  
MRS cycle with address key programs  
- CAS Latency ( 2, 3 )  
- Burst Length ( 2, 4, 8, 16 )  
- Burst Type (Sequential & Interleave)  
- Partial Self Refresh Type ( Full, 1/2, 1/4 Array )  
- Output Driver Strength Control ( Full, 1/2, 1/4, 1/8 )  
• Internal Temperature Compensated Self Refresh  
• Deep Power Down Mode  
• All inputs except data & DM are sampled at the positive going edge of the system clock(CK).  
• Data I/O transactions on both edges of data strobe, DM for masking.  
• Edge aligned data output, center aligned data input.  
• No DLL; CK to DQS is not synchronized.  
• LDM/UDM for write masking only.  
Auto refresh duty cycle  
- 7.8us for -25 to 85 °C  
Operating Frequency  
DDR266  
DDR222  
66Mhz  
Speed @CL2*1  
Speed @CL3*1  
83Mhz  
133Mhz  
111Mhz  
Note :  
1. CAS Latency  
Address configuration  
Organization  
Bank  
BA0,BA1  
Row  
Column  
16M x16  
A0 - A12  
A0 - A8  
- DM is internally loaded to match DQ and DQS identically.  
Ordering Information  
Part No.  
Max Freq.  
Interface  
LVCMOS  
Package  
K4X56163PG-L(F)GC3  
K4X56163PG-L(F)GCA  
133MHz(CL=3),83MHz(CL=2)  
111MHz(CL=3),66MHz(CL=2)  
60FBGA  
Pb (Pb Free)  
- L(F)E : 60FBGA Pb(Pb Free), Normal Power, Extended Temperature(-25 °C ~ 85 °C)  
- L(F)G : 60FBGA Pb(Pb Free), Low Power, Extended Temperature(-25 °C ~ 85 °C)  
- C3/CA : 133MHz(CL=3) / 111MHz(CL=3)  
INFORMATION IN THIS DOCUMENT IS PROVIDED IN RELATION TO SAMSUNG PRODUCTS, AND IS SUBJECT TO CHANGE WITHOUT NOTICE.  
NOTHING IN THIS DOCUMENT SHALL BE CONSTRUED AS GRANTING ANY LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE,  
TO ANY INTELLECTUAL PROPERTY RIGHTS IN SAMSUNG PRODUCTS OR TECHNOLOGY. ALL INFORMATION IN THIS DOCUMENT IS PRO-  
VIDED ON AS "AS IS" BASIS WITHOUT GUARANTEE OR WARRANTY OF ANY KIND.  
1. For updates or additional information about Samsung products, contact your nearest Samsung office.  
2. Samsung products are not intended for use in life support, critical care, medical, safety equipment, or similar applications where Product failure could  
result in loss of life or personal or physical harm, or any military or defense application, or any governmental procurement to which special terms or pro-  
visions may apply.  
January 2006  
K4X56163PG - L(F)E/G  
Mobile-DDR SDRAM  
FUNCTIONAL BLOCK DIAGRAM  
LWE  
LDM  
16  
CK, CK  
Data Input Register  
Serial to parallel  
Bank Select  
32  
2Mx32  
2Mx32  
2Mx32  
2Mx32  
32  
16  
X16  
DQi  
CK, CK  
ADD  
Column Decoder  
Latency & Burst Length  
Data Strobe  
Programming Register  
LWCBR  
LCKE  
LRAS LCBR  
LWE  
LCAS  
LDM  
Timing Register  
DM Input Register  
CK, CK  
CKE  
CS  
RAS  
CAS  
WE  
DM  
January 2006  
K4X56163PG - L(F)E/G  
Mobile-DDR SDRAM  
Package Dimension and Pin Configuration  
*2  
*1  
< Top View  
>
< Bottom View  
>
E
1
60Ball(6x9) FBGA  
9
8
7
6
5
4
3
2
1
1
2
3
7
VDDQ  
DQ1  
DQ3  
DQ5  
DQ7  
N.C.  
WE  
8
9
A
B
C
D
E
F
A
B
C
D
E
F
VSS  
VDDQ  
VSSQ  
VDDQ  
VSSQ  
VSS  
CKE  
A9  
DQ15  
VSSQ  
DQ0  
DQ2  
DQ4  
DQ6  
LDQS  
LDM  
CAS  
BA0  
A0  
VDD  
VSSQ  
VDDQ  
VSSQ  
VDDQ  
VDD  
RAS  
BA1  
A1  
DQ13 DQ14  
DQ11 DQ12  
DQ9  
DQ10  
UDQS DQ8  
UDM  
CK  
N.C.  
CK  
A12  
A8  
G
H
J
G
H
J
A11  
A7  
CS  
A6  
A10/AP  
A2  
K
VSS  
A4  
A5  
A3  
VDD  
K
E
Ball Name  
CK, CK  
CS  
Ball Function  
System Differential Clock  
Chip Select  
*2: Top View  
CKE  
Clock Enable  
A0 ~ A12  
BA0 ~ BA1  
RAS  
Address  
Bank Select Address  
Row Address Strobe  
Column Address Strobe  
Write Enable  
A
A1  
CAS  
z
b
WE  
*1: Bottom View  
L(U)DM  
L(U)DQS  
DQ0 ~ 15  
VDD/VSS  
VDDQ/VSSQ  
Data Input Mask  
Data Strobe  
*2  
Data Input/Output  
Power Supply/Ground  
Data Output Power/Ground  
< Top View >  
#A1 Ball Origin Indicator  
[Unit:mm]  
Symbol  
Min  
Typ  
-
Max  
1.00  
-
A
-
0.25  
7.9  
-
A
-
1
1
1
E
8.0  
6.4  
10.0  
7.2  
0.80  
0.50  
-
8.1  
-
E
D
9.9  
-
10.1  
-
D
e
-
-
b
z
0.45  
-
0.55  
0.10  
January 2006  
K4X56163PG - L(F)E/G  
Mobile-DDR SDRAM  
Input/Output Function Description  
SYMBOL  
CK, CK  
TYPE  
Input  
DESCRIPTION  
Clock : CK and CK are differential clock inputs. All address and control input signals are sampled on the  
crossing of the positive edge of CK and negative edge of CK. Internal clock signals are derived from  
CK/CK.  
CKE  
Input  
Input  
Clock Enable : CKE HIGH activates, and CKE LOW deactivates internal clock signals, and device input  
buffers and output drivers. Taking CKE LOW provides PRECHARGE POWER-DOWN and SELF  
REFRESH operation (all banks idle), or ACTIVE POWER-DOWN (row ACTIVE in any bank). CKE is  
synchronous for all functions except for disabling outputs, which is achieved asynchronously. Input  
buffers, excluding CK, CK and CKE , are disabled during power-down and self refresh mode which are  
contrived for low standby power consumption.  
CS  
Chip Select : CS enables(registered LOW) and disables(registered HIGH) the command decoder.  
All commands are masked when CS is registered HIGH. CS provides for external bank selection on  
systems with multiple banks. CS is considered part of the command code.  
RAS, CAS, WE Input  
Command Inputs : RAS, CAS and WE (along with CS) define the command being entered.  
LDM,UDM  
Input  
Input Data Mask : DM is an input mask signal for write data. Input data is masked when DM is sampled  
HIGH along with that input data during a WRITE access. DM is sampled on both edges of DQS. DM  
pins include dummy loading internally, to matches the DQ and DQS loading. For the x16, LDM  
corresponds to the data on DQ0-DQ7 ; UDM correspons to the data on DQ8-DQ15.  
BA0, BA1  
A [n : 0]  
Input  
Input  
Bank Addres Inputs : BA0 and BA1 define to which bank an ACTIVE, READ, WRITE or PRECHARGE  
command is being applied.  
Address Inputs : Provide the row address for ACTIVE commands, and the column address and AUTO  
PRECHARGE bit for READ/WRITE commands, to select one location out of the memory array in the  
respective bank. A10 sampled during a PRECHARGE command  
determines whether the PRECHARGE applies to one bank (A10 LOW) or all banks (A10 HIGH). If only  
one bank is to be precharged, the bank is selected by BA0, BA1. The address inputs also provide the  
op-code during a MODE REGISTER SET command. BA0 and BA1 determines which mode register  
( mode register or extended mode register ) is loaded during the MODE REGISTER SET command.  
DQ  
I/O  
I/O  
Data Input/Output : Data bus  
LDQS,UDQS  
Data Strobe : Output with read data, input with write data. Edge-aligned with read data, centered in write  
data. it is used to fetch write data. For the x16, LDQS corresponds to the data on DQ0-DQ7 ; UDQS  
corresponds to the data on DQ8-DQ15.  
NC  
-
No Connect : No internal electrical connection is present.  
DQ Power Supply : 1.7V to 1.95V.  
DQ Ground.  
VDDQ  
VSSQ  
VDD  
VSS  
Supply  
Supply  
Supply  
Supply  
Power Supply : 1.7V to 1.95V.  
Ground.  
January 2006  
K4X56163PG - L(F)E/G  
Mobile-DDR SDRAM  
Functional Description  
DEEP  
POWER  
DOWN  
CKEH  
POWER  
ON  
POWER  
APPLIED  
PARTIAL  
SELF  
REFRESH  
SELF  
REFRESH  
DEEP  
POWER  
DOWN  
PRECHARGE  
ALL BANKS  
REFS  
REFSX  
REFA  
IDLE  
ALL BANKS  
PRECHARGED  
MRS  
AUTO  
EMRS  
MRS  
REFRESH  
CKEL  
CKEH  
ACT  
POWER  
DOWN  
CKEH  
POWER  
DOWN  
ROW  
BURST STOP  
ACTIVE  
CKEL  
WRITE  
READ  
WRITEA  
READA  
READ  
WRITE  
READ  
WRITEA  
READA  
READA  
PRE  
PRE  
WRITEA  
READA  
PRE  
PRE  
PRECHARGE  
PREALL  
Automatic Sequence  
Command Sequence  
Figure.1 State diagram  
January 2006  
K4X56163PG - L(F)E/G  
Mobile-DDR SDRAM  
Mode Register Definition  
Mode Register Set(MRS)  
The mode register is designed to support the various operating modes of DDR SDRAM. It includes Cas latency, addressing mode,  
burst length, test mode and vendor specific options to make DDR SDRAM useful for variety of applications. The default value of the  
mode register is not defined, therefore the mode register must be written in the power up sequence of DDR SDRAM. The mode reg-  
ister is written by asserting low on CS, RAS, CAS and WE(The DDR SDRAM should be in active mode with CKE already high prior to  
writing into the mode register). The states of address pins A0 ~ A12 and BA0, BA1 in the same cycle as CS, RAS, CAS and WE  
going low are written in the mode register. Two clock cycles are required to complete the write operation in the mode register. Even if  
the power-up sequence is finished and some read or write operation is executed afterward, the mode register contents can be  
changed with the same command and two clock cycles. This command must be issued only when all banks are in the idle state. If  
mode register is changed, extended mode register automatically is reset and come into default state. So extended mode register  
must be set again. The mode register is divided into various fields depending on functionality. The burst length uses A0 ~ A2,  
addressing mode uses A3, Cas latency(read latency from column address) uses A4 ~ A6, A7 ~ A12 is used for test mode. BA0 and  
BA1 must be set to low for proper MRS operation.  
Address Bus  
BA1  
BA0  
A12 ~ A10/AP  
A9  
0
A8  
0
A7  
0
A6  
A5  
A4  
A3  
BT  
A2  
A1  
A0  
Mode Register  
0
0
RFU*  
CAS Latency  
Burst Length  
A3  
Burst Type  
Sequential  
Interleave  
0
1
A6  
0
A5  
0
A4  
0
CAS Latency  
Reserved  
Reserved  
2
A2  
0
A1  
0
A0  
Burst Length  
0
1
0
1
0
1
0
1
Reserved  
0
0
1
0
0
2
0
1
0
0
1
4
0
1
1
3
0
1
8
1
0
0
Reserved  
Reserved  
Reserved  
Reserved  
1
0
16  
1
0
1
1
0
Reserved  
Reserved  
Reserved  
1
1
0
1
1
1
1
1
1
1
Figure.2 Mode Register Set  
Note :  
RFU(Reserved for future use) should stay "0" during MRS cycle  
January 2006  
K4X56163PG - L(F)E/G  
Mobile-DDR SDRAM  
Burst address ordering for burst length  
Starting  
Burst  
Address  
Sequential Mode  
Interleave Mode  
Length  
(A3, A2, A1, A0)  
xxx0  
xxx1  
xx00  
xx01  
xx10  
xx11  
x000  
x001  
x010  
x011  
x100  
x101  
x110  
x111  
0000  
0001  
0010  
0011  
0100  
0101  
0110  
0111  
1000  
1001  
1010  
1011  
1100  
1101  
1110  
1111  
0, 1  
0, 1  
2
1, 0  
1, 0  
0, 1, 2, 3  
0, 1, 2, 3  
1, 2, 3, 0  
1, 0, 3, 2  
4
2, 3, 0, 1  
2, 3, 0, 1  
3, 0, 1, 2  
3, 2, 1, 0  
0, 1, 2, 3, 4, 5, 6, 7  
0, 1, 2, 3, 4, 5, 6, 7  
1, 2, 3, 4, 5, 6, 7, 0  
1, 0, 3, 2, 5, 4, 7, 6  
2, 3, 4, 5, 6, 7, 0, 1  
2, 3, 0, 1, 6, 7, 4, 5  
3, 4, 5, 6, 7, 0, 1, 2  
3, 2, 1, 0, 7, 6, 5, 4  
8
4, 5, 6, 7, 0, 1, 2, 3  
4, 5, 6, 7, 0, 1, 2, 3  
5, 6, 7, 0, 1, 2, 3, 4  
5, 4, 7, 6, 1, 0, 3, 2  
6, 7, 0, 1, 2, 3, 4, 5  
6, 7, 4, 5, 2, 3, 0, 1  
7, 0, 1, 2, 3, 4, 5, 6  
7, 6, 5, 4, 3, 2, 1, 0  
0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14,15  
1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14,15, 0  
2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14,15, 0, 1  
3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14,15, 0, 1, 2  
4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14,15, 0, 1, 2, 3  
5, 6, 7,8, 9, 10, 11, 12, 13, 14,15, 0, 1, 2, 3, 4  
6, 7, 8, 9, 10, 11, 12, 13, 14,15, 0, 1, 2, 3, 4, 5  
7, 8, 9, 10, 11, 12, 13, 14,15, 0, 1, 2, 3, 4, 5, 6  
8, 9, 10, 11, 12, 13, 14,15, 0, 1, 2, 3, 4, 5, 6, 7  
9, 10, 11, 12, 13, 14,15, 0, 1, 2, 3, 4, 5, 6, 7, 8  
10, 11, 12, 13, 14, 15, 0, 1, 2, 3, 4, 5, 6, 7, 8, 9  
11, 12, 13, 14, 15, 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10  
12, 13, 14, 15, 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11  
13, 14, 15, 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11,12  
14, 15, 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13  
15, 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14  
0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14,15  
1, 0, 3, 2, 5, 4, 7, 6, 9, 8, 11,10,13,12,15,14  
2, 3, 0, 1, 6, 7, 4, 5,10,11, 8, 9, 14,15,12,13  
3, 2, 1, 0, 7, 6, 5, 4,11,10, 9, 8, 15,14,13,12  
4, 5, 6, 7, 0, 1, 2, 3,12,13,14,15, 8, 9, 10,11  
5, 4, 7, 6, 1, 0, 3, 2,13,12,15,14, 9, 8,11,10  
6, 7, 4, 5, 2, 3, 0, 1,14,15,12,13,10,11, 8, 9  
7, 6, 5, 4, 3, 2, 1, 0, 15,14,13,12,11,10, 9, 8  
8, 9,10,11,12,13,14,15, 0, 1, 2, 3, 4, 5, 6, 7  
9, 8, 11,10,13,12,15,14,1, 0, 3, 2, 5, 4, 7, 6  
10,11, 8, 9, 14,15,12,13, 2, 3, 0, 1, 6, 7, 4, 5  
11,10, 9, 8, 15,14,13,12, 3, 2, 1, 0, 7, 6, 5, 4  
12,13,14,15, 8, 9, 10,11, 4, 5, 6, 7, 0, 1, 2, 3  
13,12,15,14, 9, 8,11,10, 5, 4, 7, 6, 1, 0, 3, 2  
14,15,12,13,10,11, 8, 9, 6, 7, 4, 5, 2, 3, 0, 1  
15,14,13,12,11,10, 9, 8, 7, 6, 5, 4, 3, 2, 1, 0  
16  
January 2006  
K4X56163PG - L(F)E/G  
Mobile-DDR SDRAM  
Extended Mode Register Set(EMRS)  
The extended mode register is designed to support partial array self refresh or driver strength control. EMRS cycle is not mandatory  
and the EMRS command needs to be issued only when either PASR or DS is used. The default state without EMRS command  
issued is half driver strength, and Full array refreshed. The extended mode register is written by asserting low on CS, RAS, CAS,  
WE and high on BA1 ,low on BA0(The DDR SDRAM should be in all bank precharge with CKE already high prior to writing into the  
extended mode register). The state of address pins A0 ~ A12 in the same cycle as CS, RAS, CAS and WE going low is written in the  
extended mode register. Two clock cycles are required to complete the write operation in the extended mode register. Even if the  
power-up sequence is finished and some read or write operations is executed afterward, the mode register contents can be changed  
with the same command and two clock cycles. But this command must be issued only when all banks are in the idle state. A0 - A2  
are used for partial array self refresh and A5 - A6 are used for driver strength control. "High" on BA1 and"Low" on BA0 are used for  
EMRS. All the other address pins except A0,A1,A2,A5,A6, BA1, BA0 must be set to low for proper EMRS operation. Refer to the  
table for specific codes.  
Extended MRS for PASR(Partial Array Self Refresh) &  
DS(Driver Strength Control)  
Address Bus  
A12 ~ A10/AP  
BA1  
BA0  
A9  
A8  
A7  
A6  
A5  
A4  
A3  
A2  
A1  
A0  
0
DS  
RFU*  
PASR  
Mode Register  
1
0
RFU*  
0
0
DS  
Internal TCSR  
PASR  
A6  
A5  
Driver Strength  
Self refresh cycle is controlled  
automatically by internal tem-  
perature sensor and control cir-  
cuit according to the three  
temperature ranges ; 45 °C and  
85 °C  
A2  
0
A1  
A0  
0
Refreshed Area  
0
0
1
1
0
1
0
1
Full  
1/2  
1/4  
1/8  
0
0
1
1
0
0
1
1
Full Array  
1/2 of Full Array  
1/4 of Full Array  
Reserved  
0
1
0
0
0
1
1
0
Reserved  
1
1
Reserved  
1
0
Reserved  
1
1
Reserved  
Figure.3 Extended Mode Register Set  
Note :  
RFU(Reserved for future use) should stay "0" during EMRS cycle  
January 2006  
K4X56163PG - L(F)E/G  
Mobile-DDR SDRAM  
Internal Temperature Compensated Self Refresh (TCSR)  
Note :  
1. In order to save power consumption, Mobile DDR SDRAM includes the internal temperature sensor and control units to control the  
self refresh cycle automatically according to the three temperature ranges ; 45 °C and 85 °C.  
2. If the EMRS for external TCSR is issued by the controller, this EMRS code for TCSR is ignored.  
3. It has +/- 5 °C tolerance.  
Self Refresh Current (IDD6)  
Temperature Range  
- E  
1/2 Array  
160  
- G  
1/2 Array  
135  
Unit  
Full Array  
200  
1/4 Array  
140  
Full Array  
150  
1/4 Array  
130  
*3  
45 °C  
uA  
85 °C  
450  
300  
250  
300  
250  
225  
Partial Array Self Refresh (PASR)  
Note :  
1. In order to save power consumption, Mobile-DDR SDRAM includes PASR option.  
2. Mobile-DDR SDRAM supports three kinds of PASR in self refresh mode; Full array, 1/2 Array, 1/4 Array.  
BA1=0 BA1=0  
BA0=0 BA0=1  
BA1=0 BA1=0  
BA0=0 BA0=1  
BA1=0 BA1=0  
BA0=0 BA0=1  
BA1=1 BA1=1  
BA0=0 BA0=1  
BA1=1 BA1=1  
BA0=0 BA0=1  
BA1=1 BA1=1  
BA0=0 BA0=1  
- 1/4 Array  
- Full Array  
- 1/2 Array  
Partial Self Refresh Area  
Figure.4 EMRS code and TCSR , PASR  
January 2006  
K4X56163PG - L(F)E/G  
Mobile-DDR SDRAM  
Absolute maximum ratings  
Parameter  
Symbol  
, V  
OUT  
Value  
Unit  
Voltage on any pin relative to V  
V
-0.5 ~ 2.7  
-0.5 ~ 2.7  
-0.5 ~ 2.7  
-55 ~ +150  
1.0  
V
SS  
IN  
Voltage on V supply relative to V  
V
DD  
V
V
DD  
SS  
Voltage on V  
supply relative to V  
V
DDQ  
DDQ  
SS  
Storage temperature  
Power dissipation  
Short circuit current  
T
°C  
W
STG  
P
D
I
50  
mA  
OS  
Note :  
Permanent device damage may occur if ABSOLUTE MAXIMUM RATINGS are exceeded.  
Functional operation should be restricted to recommend operation condition.  
Exposure to higher than recommended voltage for extended periods of time could affect device reliability.  
DC Operating Conditions  
Recommended operating conditions(Voltage referenced to VSS=0V, Tc = -25°C to 85°C)  
Parameter  
Supply voltage(for device with a nominal VDD of 1.8V)  
I/O Supply voltage  
Symbol  
VDD  
Min  
Max  
Unit  
V
Note  
1.7  
1.95  
1
VDDQ  
VIH(DC)  
VIL(DC)  
VOH(DC)  
VOL(DC)  
II  
1.7  
1.95  
V
1
Input logic high voltage  
0.7 x VDDQ  
VDDQ+0.3  
V
2
Input logic low voltage  
-0.3  
0.3 x VDDQ  
V
2
Output logic high voltage  
Output logic low voltage  
0.9 x VDDQ  
-
V
IOH = -0.1mA  
IOL = 0.1mA  
-
0.1 x VDDQ  
V
Input leakage current  
-2  
-5  
2
5
uA  
uA  
Output leakage current  
IOZ  
Note :  
1. Under all conditions, VDDQ must be less than or equal to VDD.  
2. These parameters should be tested at the pin on actual components and may be checked at either the pin or the pad in simulation.  
January 2006  
K4X56163PG - L(F)E/G  
Mobile-DDR SDRAM  
DC CHARACTERISTICS  
Recommended operating conditions (Voltage referenced to VSS = 0V, Tc = -25 to 85°C)  
Parameter  
Symbol  
Test Condition  
DDR266 DDR222 Unit  
Operating Current  
(One Bank Active)  
tRC = tRCmin ; tCK = tCKmin ; CKE is HIGH; CS is HIGH between valid commands;  
address inputs are SWITCHING; data bus inputs are STABLE  
IDD0  
50  
45  
mA  
all banks idle, CKE is LOW; CS is HIGH, tCK = t CKmin ; address and control inputs are  
SWITCHING; data bus inputs are STABLE  
0.3  
0.3  
IDD2P  
Precharge Standby Current in  
power-down mode  
mA  
all banks idle, CKE is LOW; CS is HIGH, CK = LOW, CK = HIGH; address and control  
inputs are SWITCHING; data bus inputs are STABLE  
IDD2PS  
IDD2N  
all banks idle, CKE is HIGH; CS is HIGH, tCK = t CKmin ;address and control inputs are  
SWITCHING; data bus inputs are STABLE  
12  
8
10  
6
Precharge Standby Current  
in non power-down mode  
mA  
mA  
all banks idle, CKE is HIGH; CS is HIGH, CK = LOW, CK = HIGH; address and control  
inputs are SWITCHING; data bus inputs are STABLE  
IDD2NS  
IDD3P  
one bank active, CKE is LOW; CS is HIGH, tCK = tCKmin ;address and control inputs are  
SWITCHING; data bus inputs are STABLE  
5
2
Active Standby Current  
in power-down mode  
one bank active, CKE is LOW; CS is HIGH, CK = LOW, CK = HIGH;address and control  
inputs are SWITCHING; data bus inputs are STABLE  
IDD3PS  
IDD3N  
one bank active, CKE is HIGH; CS is HIGH, tCK = tCKmin ;address and control inputs  
are SWITCHING; data bus inputs are STABLE  
25  
20  
20  
15  
Active Standby Current  
in non power-down mode  
(One Bank Active)  
mA  
mA  
one bank active, CKE is HIGH; CS is HIGH, CK = LOW, CK = HIGH;  
address and control inputs are SWITCHING; data bus inputs are STABLE  
IDD3NS  
one bank active; BL = 4; CL = 3; tCK = tCKmin ; continuous read bursts; I OUT = 0 mA  
address inputs are SWITCHING; 50% data change each burst transfer  
IDD4R  
IDD4W  
IDD5  
100  
90  
85  
80  
Operating Current  
(Burst Mode)  
one bank active; BL = 4; tCK = tCKmin ; continuous write bursts;address inputs are  
SWITCHING; 50% data change each burst transfer  
tRC = tRFCmin ; tCK = tCKmin ; burst refresh; CKE is HIGH;address and control inputs  
are SWITCHING; data bus inputs are STABLE  
Refresh Current  
100  
90  
85  
mA  
1
TCSR Range  
Full Array  
°C  
CKE is LOW; tCK = tCKmin ;  
45*  
200  
160  
140  
150  
135  
130  
Extended Mode Register set to all 0’s;  
address and control inputs are STABLE;  
data bus inputs are STABLE  
450  
300  
250  
300  
250  
225  
-E  
1/2 Array  
1/4 Array  
Full Array  
1/2 Array  
1/4 Array  
Self Refresh Current  
IDD6  
uA  
uA  
-G  
2
Deep Power Down Current  
10  
IDD8*  
Address and control inputs are STABLE; data bus inputs are STABLE  
Note :  
1. It has +/- 5°C tolerance.  
2. DPD(Deep Power Down) function is an optional feature, and it will be enabled upon request.  
Please contact Samsung for more information.  
3. IDD specifications are tested after the device is properly intialized.  
4. Input slew rate is 1V/ns.  
5. Definitions for IDD: LOW is defined as V IN 0.1 * V DDQ ;  
HIGH is defined as V IN 0.9 * V DDQ ;  
STABLE is defined as inputs stable at a HIGH or LOW level ;  
SWITCHING is defined as: - address and command: inputs changing between HIGH and LOW once per two clock cycles ;  
- data bus inputs: DQ changing between HIGH and LOW once per clock cycle; DM and DQS are STABLE.  
January 2006  
K4X56163PG - L(F)E/G  
Mobile-DDR SDRAM  
AC Operating Conditions & Timming Specification  
Max  
Parameter/Condition  
Symbol  
Min  
Unit  
Note  
Input High (Logic 1) Voltage, all inputs  
Input Low (Logic 0) Voltage, all inputs  
Input Crossing Point Voltage, CK and CK inputs  
VIH(AC)  
VIL(AC)  
VIX(AC)  
0.8 x VDDQ  
-0.3  
VDDQ+0.3  
0.2 x VDDQ  
0.6 x VDDQ  
V
V
V
1
1
2
0.4 x VDDQ  
Note :  
1. These parameters should be tested at the pin on actual components and may be checked at either the pin or the pad in simulation.  
2. The value of VIX is expected to equal 0.5*VDDQ of the transmitting device and must track variations in the DC level of the same.  
January 2006  
K4X56163PG - L(F)E/G  
Mobile-DDR SDRAM  
AC Timming Parameters & Specifications  
DDR266  
DDR222  
Parameter  
Symbol  
Unit  
Note  
Min  
Max  
Min  
Max  
CL=2  
CL=3  
12.0  
7.5  
15.0  
Clock cycle time  
tCK  
ns  
9.0  
Row cycle time  
tRC  
tRAS  
tRCD  
tRP  
67.5  
45  
81  
ns  
ns  
ns  
ns  
ns  
ns  
-
Row active time  
RAS to CAS delay  
Row precharge time  
70,000  
54  
70,000  
22.5  
22.5  
15  
27  
27  
Row active to Row active delay  
Write recovery time  
tRRD  
tWR  
15  
15  
15  
Last data in to Active delay  
Last data in to Read command  
Col. address to Col. address delay  
tDAL  
tCDLR  
tCCD  
2tCK+tRP  
1
2tCK+tRP  
2
3
1
1
tCK  
1
tCK  
Clock high level width  
Clock low level width  
tCH  
tCL  
0.45  
0.45  
2
0.55  
0.55  
8
0.45  
0.45  
2.5  
0.55  
0.55  
8
tCK  
tCK  
CL=2  
CL=3  
CL=2  
CL=3  
DQ Output data access time from CK/  
CK  
tAC  
ns  
2
6
2.5  
6
2
8
2.5  
8
DQS Output data access time from  
CK/CK  
tDQSCK  
tDQSQ  
tRPRE  
ns  
ns  
2
6
2.5  
6
Data strobe edge to ouput data edge  
Read Preamble  
0.6  
1.1  
1.1  
0.6  
1.25  
0.7  
1.1  
1.1  
0.6  
1.25  
CL=2  
CL=3  
0.5  
0.9  
0.4  
0.75  
0
0.5  
0.9  
0.4  
0.75  
0
tCK  
Read Postamble  
tRPST  
tDQSS  
tWPRES  
tWPREH  
tDQSH  
tDQSL  
tDSS  
tDSH  
tDSC  
tIS  
tCK  
tCK  
ns  
CK to valid DQS-in  
DQS-in setup time  
4
DQS-in hold time  
0.25  
0.4  
0.4  
0.2  
0.2  
0.9  
1.3  
1.3  
2.6  
0.8  
0.25  
0.4  
0.4  
0.2  
0.2  
0.9  
1.5  
1.5  
3.0  
1.1  
tCK  
tCK  
tCK  
tCK  
tCK  
tCK  
ns  
DQS-in high level width  
0.6  
0.6  
0.6  
0.6  
DQS-in low level width  
DQS falling edge to CK setup time  
DQS falling edge hold time from CK  
DQS-in cycle time  
1.1  
1.1  
Address and Control Input setup time  
Address and Control Input hold time  
Address & Control input pulse width  
DQ & DM setup time to DQS  
DQ & DM hold time to DQS  
1
1
tIH  
ns  
tIPW  
1
tDS  
ns  
ns  
5,6  
tDH  
0.8  
1.1  
5,6  
DQ & DM input pulse width  
tDIPW  
tLZ  
1.8  
1.0  
2.4  
1.0  
ns  
ns  
DQ & DQS low-impedence time from CK/CK  
DQ & DQS high-impedence time from CK/CK  
DQS write postamble time  
tHZ  
6.0  
0.6  
7.0  
0.6  
ns  
tWPST  
tWPRE  
0.4  
0.4  
tCK  
tCK  
DQS write preamble time  
0.25  
0.25  
January 2006  
K4X56163PG - L(F)E/G  
Mobile-DDR SDRAM  
DDR222  
DDR266  
Max  
Parameter  
Symbol  
Unit  
Note  
Min  
Min  
Max  
Refresh interval time  
tREF  
64  
64  
ms  
tCK  
ns  
Mode register set cycle time  
Power down exit time  
tMRD  
2
2
tPDEX 1*tCK +tIS  
1*tCK +tIS  
CKE min. pulse width(high and low pulse width)  
Auto refresh cycle time  
tCKE  
tRFC  
tXSR  
2
2
tCK  
ns  
80  
90  
7
Exit self refresh to active command  
120  
120  
ns  
tHPmin -  
tQHS  
tHPmin -  
tQHS  
Data hold from DQS to earliest DQ edge  
Data hold skew factor  
tQH  
tQHS  
tHP  
ns  
ns  
ns  
0.75  
1.0  
tCLmin or  
tCHmin  
tCLmin or  
tCHmin  
Clock half period  
January 2006  
K4X56163PG - L(F)E/G  
Mobile-DDR SDRAM  
Note :  
1. Input Setup/Hold Slew Rate Derating  
Input Setup/Hold Slew Rate  
tIS  
(ps)  
0
tIH  
(ps)  
0
(V/ns)  
1.0  
0.8  
+50  
+100  
+50  
+100  
0.6  
This derating table is used to increase t /t in the case where the input slew rate is below 1.0V/ns.  
IS IH  
2. Minimum 3CLK of tDAL(= tWR + tRP) is required because it need minimum 2CLK for tWR and minimum 1CLK for tRP.  
3. tAC(min) value is measured at the high Vdd(1.95V) and cold temperature(-25°C).  
tAC(max) value is measured at the low Vdd(1.7V) and hot temperature(85°C).  
tAC is measured in the device with half driver strength and under the AC output load condition (Fig.7 in next Page).  
4. The specific requirement is that DQS be valid(High or Low) on or before this CK edge. The case shown(DQS going from  
High_Z to logic Low) applies when no writes were previously in progress on the bus. If a previous write was in progress,  
DQS could be High at this time, depending on tDQSS.  
5. I/O Setup/Hold Slew Rate Derating  
I/O Setup/Hold Slew Rate  
tDS  
(ps)  
0
tDH  
(ps)  
0
(V/ns)  
1.0  
0.8  
+75  
+150  
+75  
+150  
0.6  
This derating table is used to increase t /t in the case where the I/O slew rate is below 1.0V/ns.  
DS DH  
6. I/O Delta Rise/Fall Rate(1/slew-rate) Derating  
Delta Rise/Fall Rate  
tDS  
(ps)  
0
tDH  
(ps)  
0
(ns/V)  
0
±0.25  
±0.5  
+50  
+100  
+50  
+100  
This derating table is used to increase tDS/tDH in the case where the DQ and DQS slew rates differ. The Delta Rise/Fall Rate  
is calculated as 1/SlewRate1-1/SlewRate2. For example, if slew rate 1 = 1.0V/ns and slew rate 2 =0.8V/ns, then the Delta Rise/Fall  
Rate =-0.25ns/V.  
7. Maximum burst refresh cycle : 8  
January 2006  
K4X56163PG - L(F)E/G  
Mobile-DDR SDRAM  
AC Operating Test Conditions(VDD = 1.7V to 1.95V, Tc = -25 to 85°C)  
Parameter  
AC input levels (Vih/Vil)  
Value  
Unit  
0.8 x VDDQ / 0.2 x VDDQ  
0.5 x VDDQ  
V
V
Input timing measurement reference level  
Input signal minimum slew rate  
1.0  
V/ns  
V
Output timing measurement reference level  
Output load condition  
0.5 x VDDQ  
See Figure.7  
1.8V  
Vtt=0.5 x VDDQ  
13.9KΩ  
VOH (DC) = 0.9 x VDDQ , IOH = -0.1mA  
VOL (DC) = 0.1 x VDDQ , IOL = 0.1mA  
20pF  
Output  
50Ω  
10.6KΩ  
Output  
Z0=50Ω  
20pF  
Figure.6 DC Output Load Circuit  
Figure.7 AC Output Load Circuit  
Input/Output Capacitance(VDD=1.8, VDDQ=1.8V, TC = 25°C, f=1MHz)  
Parameter  
Symbol  
Min  
Max  
Unit  
Input capacitance  
(A0 ~ A12, BA0 ~ BA1, CKE, CS, RAS,CAS, WE)  
CIN1  
1.5  
3.0  
pF  
Input capacitance( CK, CK )  
CIN2  
COUT  
CIN3  
1.5  
2.0  
2.0  
3.5  
4.5  
4.5  
pF  
pF  
pF  
Data & DQS input/output capacitance  
Input capacitance(DM)  
January 2006  
K4X56163PG - L(F)E/G  
Mobile-DDR SDRAM  
AC Overshoot/Undershoot Specification for Address & Control Pins  
Parameter  
Specification  
0.9V  
Maximum peak Amplitude allowed for overshoot area  
Maximum peak Amplitude allowed for undershoot area  
Maximum overshoot area above VDD  
0.9V  
3V-ns  
Maximum undershoot area below VSS  
3V-ns  
Maximum Amplitude  
Overshoot Area  
VDD  
VSS  
Volts  
(V)  
Undershoot Area  
Maximum Amplitude  
Time (ns)  
Figure.8 AC Overshoot and Undershoot Definition for Address and Control Pins  
AC Overshoot/Undershoot Specification for CLK, DQ, DQS and DM Pins  
Parameter  
Specification  
0.9V  
Maximum peak Amplitude allowed for overshoot area  
Maximum peak Amplitude allowed for undershoot area  
Maximum overshoot area above VDDQ  
0.9V  
3V-ns  
Maximum undershoot area below VSSQ  
3V-ns  
Maximum Amplitude  
Overshoot Area  
VDDQ  
VSSQ  
Volts  
(V)  
Undershoot Area  
Maximum Amplitude  
Time (ns)  
Figure.9 AC Overshoot and Undershoot Definition for CLK, DQ, DQS and DM Pins  
January 2006  
K4X56163PG - L(F)E/G  
Mobile-DDR SDRAM  
Command Truth Table(V=Valid, X=Dont Care, H=Logic High, L=Logic Low)  
A12,A11,  
A9 ~ A0  
COMMAND  
Mode Register Set  
CKEn-1 CKEn CS  
RAS  
CAS  
WE BA0,1 A10/AP  
Note  
Register  
Refresh  
H
H
X
H
L
L
L
L
L
L
OP CODE  
1, 2  
3
Auto Refresh  
L
L
H
X
X
Entry  
Exit  
3
Self  
Refresh  
L
H
L
H
X
L
H
X
H
H
X
H
3
L
H
H
H
X
X
3
Bank Active & Row Addr.  
V
V
Row Address  
Read &  
Auto Precharge Disable  
Auto Precharge Enable  
L
Column  
Address  
(A0~A8)  
4
4
L
L
H
H
L
L
H
L
Column Address  
H
Write &  
Auto Precharge Disable  
Auto Precharge Enable  
L
Column  
Address  
(A0~A8)  
4
H
X
V
Column Address  
H
4, 6  
Entry  
Exit  
H
L
L
H
X
L
H
L
H
X
H
H
X
H
L
X
L
Deep Power Down  
Burst Stop  
X
X
H
7
5
Bank Selection  
All Banks  
V
X
L
Precharge  
H
X
L
L
H
L
X
H
H
L
X
V
X
X
H
X
V
X
X
H
X
V
X
X
H
X
V
X
V
X
X
H
X
V
Entry  
H
L
L
H
L
Active Power Down  
X
X
Exit  
X
H
L
Entry  
H
Precharge Power Down  
H
L
Exit  
L
H
H
H
X
DM  
X
X
8
9
9
H
L
X
H
X
H
No operation (NOP) : Not defined  
Note :  
1. OP Code : Operand Code. A0 ~ A12 & BA0 ~ BA1 : Program keys. (@EMRS/MRS)  
2.EMRS/ MRS can be issued only at all banks precharge state.  
A new command can be issued 2 clock cycles after EMRS or MRS.  
3. Auto refresh functions are same as the CBR refresh of DRAM.  
The automatical precharge without row precharge command is meant by "Auto".  
Auto/self refresh can be issued only at all banks precharge state.  
4. BA0 ~ BA1 : Bank select addresses.  
5. If A10/AP is "High" at row precharge, BA0 and BA1 are ignored and all banks are selected.  
6. During burst write with auto precharge, new read/write command can not be issued.  
Another bank read/write command can be issued after the end of burst.  
New row active of the associated bank can be issued at tRP after the end of burst.  
7. Burst stop command is valid at every burst length.  
8. DM sampled at the rising and falling edges of the DQS and Data-in are masked at the both edges (Write DM latency is 0).  
9. This combination is not defined for any function, which means "No Operation(NOP)" in DDR SDRAM.  
January 2006  
K4X56163PG - L(F)E/G  
Mobile-DDR SDRAM  
Functional Truth Table  
Current State  
CS  
L
RAS CAS  
WE  
L
Address  
Command  
Action  
*2  
*2  
PRECHARGE  
STANDBY  
H
H
L
H
L
X
Burst Stop  
READ/WRITE  
Active  
ILLEGAL  
ILLEGAL  
L
X
BA, CA, A10  
BA, RA  
L
H
H
H
Bank Active, Latch RA  
*4  
L
L
L
BA, A10  
PRE/PREA  
ILLEGAL  
*5  
L
L
L
L
L
L
L
H
L
L
X
Refresh  
MRS  
AUTO-Refresh  
*5  
Op-Code, Mode-Add  
X
Mode Register Set  
ACTIVE  
H
H
Burst Stop  
NOP  
STANDBY  
Begin Read, Latch CA,  
Determine Auto-Precharge  
L
L
H
H
L
L
H
L
BA, CA, A10  
BA, CA, A10  
READ/READA  
Begin Write, Latch CA,  
Determine Auto-Precharge  
WRITE/WRITEA  
*2  
L
L
L
L
L
L
L
L
L
H
H
H
L
H
L
BA, RA  
Active  
Bank Active/ILLEGAL  
BA, A10  
PRE/PREA  
Refresh  
MRS  
Precharge/Precharge All  
ILLEGAL  
H
L
X
L
Op-Code, Mode-Add  
X
ILLEGAL  
READ  
H
L
Burst Stop  
Terminate Burst  
Terminate Burst, Latch CA,  
Begin New Read, Determine  
L
H
L
H
BA, CA, A10  
READ/READA  
*3  
Auto-Precharge  
L
L
L
L
L
H
L
L
L
L
L
H
H
L
L
H
L
BA, CA, A10  
BA, RA  
BA, A10  
X
WRITE/WRITEA  
Active  
ILLEGAL  
*2  
Bank Active/ILLEGAL  
PRE/PREA  
Refresh  
Terminate Burst, Precharge  
ILLEGAL  
H
L
L
Op-Code, Mode-Add MRS  
ILLEGAL  
January 2006  
K4X56163PG - L(F)E/G  
Mobile-DDR SDRAM  
Functional truth table  
Current State  
CS  
RAS CAS WE  
Address  
Command  
Burst Stop  
Action  
ILLEGAL  
WRITE  
L
H
H
L
X
Terminate Burst With DM=High, Latch CA,  
*3  
L
L
H
L
H
BA, CA, A10  
BA, CA, A10  
READ/READA  
Begin Read, Determine Auto-Precharge  
Terminate Burst, Latch CA,  
Begin new Write, Determine Auto-Pre-  
H
L
L
WRITE/WRITEA  
*3  
charge  
*2  
L
L
L
L
H
H
H
L
BA, RA  
BA, A10  
X
Active  
Bank Active/ILLEGAL  
Terminate Burst With DM=High,  
Precharge  
PRE/PREA  
Refresh  
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
H
L
ILLEGAL  
ILLEGAL  
ILLEGAL  
*6  
Op-Code, Mode-Add MRS  
READ with  
AUTO  
H
H
H
L
H
L
L
X
Burst Stop  
READ/READA  
H
L
BA, CA, A10  
BA, CA, A10  
BA, RA  
BA, A10  
X
*6  
PRECHARGE  
(READA)  
L
WRITE/WRITEA ILLEGAL  
H
H
L
H
L
Active  
*6  
L
PRE/PREA  
Refresh  
*6  
L
H
L
ILLEGAL  
ILLEGAL  
ILLEGAL  
*7  
L
L
Op-Code, Mode-Add MRS  
WRITE with  
AUTO  
H
H
H
L
H
L
L
X
Burst Stop  
READ/READA  
WRITE/WRITEA *7  
H
L
BA, CA, A10  
BA, CA, A10  
BA, RA  
BA, A10  
X
*7  
RECHARGE  
(WRITEA)  
L
H
H
L
H
L
Active  
*7  
L
PRE/PREA  
Refresh  
*7  
L
H
L
ILLEGAL  
ILLEGAL  
L
L
Op-Code, Mode-Add MRS  
January 2006  
K4X56163PG - L(F)E/G  
Mobile-DDR SDRAM  
Functional truth table  
Current State  
CS  
L
RAS  
H
CAS  
H
WE  
L
Address  
Command  
Action  
*2  
PRECHARGING  
(DURING tRP)  
X
Burst Stop  
READ/WRITE  
Active  
ILLEGAL  
ILLEGAL  
*2  
*2  
L
H
L
X
BA, CA, A10  
BA, RA  
L
L
H
H
ILLEGAL  
*4  
L
L
L
L
L
L
H
L
L
H
L
BA, A10  
PRE/PREA  
Refresh  
NOP (Idle after tRP)  
ILLEGAL  
X
L
L
Op-Code, Mode-Add  
X
MRS  
ILLEGAL  
*2  
ROW  
ACTIVATING  
H
H
L
Burst Stop  
ILLEGAL  
*2  
L
L
H
L
L
X
H
BA, CA, A10  
READ/WRITE  
Active  
ILLEGAL  
(FROM ROW  
ACTIVE TO  
tRCD)  
*2  
H
BA, RA  
ILLEGAL  
*2  
BA, A10  
L
L
L
L
L
L
H
L
L
H
L
PRE/PREA  
Refresh  
ILLEGAL  
X
ILLEGAL  
ILLEGAL  
L
L
Op-Code, Mode-Add  
X
MRS  
*2  
WRITE  
RECOVERING  
H
H
L
Burst Stop  
ILLEGAL  
*2  
L
L
L
L
L
L
H
H
L
L
L
L
L
L
H
L
BA, CA, A10  
BA, CA, A10  
BA, RA  
READ  
ILLEGAL  
(DURING tWR  
OR tCDLR)  
WRITE  
Active  
WRITE  
*2  
H
H
L
H
L
ILLEGAL  
*2  
BA, A10  
PRE/PREA  
Refresh  
MRS  
ILLEGAL  
H
L
X
ILLEGAL  
ILLEGAL  
L
Op-Code, Mode-Add  
January 2006  
K4X56163PG - L(F)E/G  
Mobile-DDR SDRAM  
Functional truth table  
Current State  
CS  
L
RAS  
H
H
L
CAS  
H
L
WE  
L
Address  
Command  
Action  
RE-  
FRESHING  
X
Burst Stop  
READ/WRITE  
Active  
ILLEGAL  
ILLEGAL  
ILLEGAL  
ILLEGAL  
ILLEGAL  
ILLEGAL  
ILLEGAL  
ILLEGAL  
ILLEGAL  
ILLEGAL  
ILLEGAL  
ILLEGAL  
L
X
H
L
BA, CA, A10  
L
H
H
L
BA, RA  
L
L
BA, A10  
PRE/PREA  
Refresh  
L
L
H
L
X
L
L
L
Op-Code, Mode-Add  
MRS  
MODE  
REGISTER  
SETTING  
L
H
H
L
H
L
L
X
Burst Stop  
READ/WRITE  
Active  
L
X
H
L
BA, CA, A10  
BA, RA  
L
H
H
L
BA, A10  
L
L
PRE/PREA  
Refresh  
L
L
H
L
X
L
L
L
Op-Code, Mode-Add  
MRS  
January 2006  
K4X56163PG - L(F)E/G  
Mobile-DDR SDRAM  
Functional truth table  
CKE  
n-1  
CKE  
n
Current State  
CS  
RAS  
CAS  
WE  
Add  
Action  
SELF-  
L
L
H
H
H
H
H
L
H
L
X
H
H
H
L
X
H
H
L
X
H
L
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Exit Self-Refresh  
*8  
REFRESHING  
Exit Self-Refresh  
L
L
ILLEGAL  
L
L
X
X
X
X
X
X
X
X
H
X
H
L
ILLEGAL  
L
L
X
X
X
X
X
X
X
L
ILLEGAL  
L
X
X
X
H
X
X
L
X
X
X
X
X
X
L
NOPeration(Maintain Self-Refresh)  
Exit Power Down(Idle after tPDEX)  
NOPeration(Maintain Power Down)  
POWER  
DOWN  
L
H
L
L
*10  
DEEP POWER  
DOWN  
L
H
L
Exit Deep Power Down  
L
NOPeration(Maintain Deep Power Down)  
Refer to Function True Table  
Enter Self-Refresh  
ALL BANKS  
IDLE*9  
H
H
H
H
H
H
H
H
L
H
L
L
H
L
X
H
H
H
H
L
X
H
H
H
L
Enter Power Down  
L
Enter Power Down  
L
L
Enter Deep Power Down  
ILLEGAL  
L
L
L
L
L
X
X
X
X
ILLEGAL  
L
L
X
X
X
ILLEGAL  
X
H
X
X
X
X
Refer to Current State=Power Down  
Refer to Function Truth Table  
ANY STATE  
other than  
H
listed above  
ABBREVIATIONS :  
H=High Level, L=Low level, X=Dont Care  
Note :  
1. All entries assume that CKE was High during the preceding clock cycle and the current clock cycle.  
2. ILLEGAL to bank in specified state ; function may be legal in the bank indicated by BA, depending on the state of that bank.(ILLEGAL = Device oper-  
ation and/or data integrity are not guaranteed.)  
3. Must satisfy bus contention, bus turn around and write recovery requirements.  
4. NOP to bank precharging or in idle sate. May precharge bank indicated by BA.  
5. ILLEGAL if any bank is not idle.  
6. Refer to "Read with Auto Precharge Timing Diagram" for detailed information.  
7. Refer to "Write with Auto Precharge Timing Diagram" for detailed information.  
8. CKE Low to High transition will re-enable CK, CK and other inputs asynchronously. A minimum setup time must be satisfied before issuing any com-  
mand other than EXIT.  
9. Power-Down, Self-Refresh and Deep Power Down Mode can be entered only from All Bank Idle state.  
10. The Deep Power Down Mode is exited by asserting CKE high and full initialization is required after exiting Deep Power Down Mode.  
January 2006  

相关型号:

K4X56163PG-FGCA0

DDR DRAM, 16MX16, 6ns, CMOS, PBGA60, LEAD FREE, FBGA-60
SAMSUNG

K4X56163PG-LGC30

DDR DRAM, 16MX16, 6ns, CMOS, PBGA60, FBGA-60
SAMSUNG

K4X56163PG-LGCA0

DDR DRAM, 16MX16, 6ns, CMOS, PBGA60, FBGA-60
SAMSUNG

K4X56163PI-L(F)E/GC3

16Mx16 Mobile DDR SDRAM
SAMSUNG

K4X56163PI-L(F)E/GC6

16Mx16 Mobile DDR SDRAM
SAMSUNG

K4X56163PI-LFE/GC3

16Mx16 Mobile DDR SDRAM
SAMSUNG

K4X56163PI-LFE/GC6

16Mx16 Mobile DDR SDRAM
SAMSUNG

K4X56323PG

8M x32 Mobile-DDR SDRAM
SAMSUNG

K4X56323PG-7EC3

8M x32 Mobile-DDR SDRAM
SAMSUNG

K4X56323PG-7EC30

DDR DRAM, 8MX32, 6ns, CMOS, PBGA90, FBGA-90
SAMSUNG

K4X56323PG-7EC3T

DDR DRAM, 8MX32, 6ns, CMOS, PBGA90,
SAMSUNG

K4X56323PG-7ECA

8M x32 Mobile-DDR SDRAM
SAMSUNG