ECDP-04-03.75-B1-B1-2-1 [SAMTEC]

Interconnection Device, ROHS COMPLIANT;
ECDP-04-03.75-B1-B1-2-1
型号: ECDP-04-03.75-B1-B1-2-1
厂家: SAMTEC    SAMTEC
描述:

Interconnection Device, ROHS COMPLIANT

连接器
文件: 总1页 (文件大小:963K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
F-213 (Rev 4SEP13)  
(0,80 mm) .0315"  
ECDP SERIES  
ECDP–08–03.75–B1–B2–3–1  
ECDP–32–03.75–L1–L2–1–1  
TWINAX EDGE CARD CABLE ASSEMBLY  
Low Profile vs.  
Mini-SAS  
Mates with:  
HSEC8 (–L2 option),  
HSEC8 (–BL option)  
SPECIFICATIONSi  
For complete specifications  
see www.samtec.com?ECDP  
Cable:  
APPLICATION  
30 AWG twinax  
AcceleRate™ cable  
Plating:  
30 AWG, 100Ω  
AcceleRate™  
twinax cable  
Edge Card = ENIG,  
3-10 microinches  
Operating Temp Range:  
-55°C to 85°C  
Impedance:  
-1 = 100Ω Differential  
-2 = 85Ω Differential  
Bend Radius:  
TM  
1 mm one time bend  
SI Performance:  
8.28 GHz @ -7db, 1m length  
Pinout Map:  
See web address above  
RoHS Compliant:  
Yes  
Metal  
squeeze latch  
Mates with vertical or right angle  
connectors on board  
RECOGNITIONS  
For complete scope of  
recognitions see  
www.samtec.com/quality  
NO. OF  
PAIRS  
WIRE  
LENGTH  
END  
1
END  
2
WIRING  
OPTION  
IMPEDANCE  
ECDP  
–L1  
= Double  
Vertical  
with  
latches  
(Wiring  
option –3  
& –4 only)  
–L1  
= Double  
Vertical  
with  
–1  
–1  
= Pin 1 to  
Pin 1  
= 100Ω  
–04, –08,  
–“XX.XX”  
= Wire Length  
in Inches  
(95,3 mm) 03.75"  
minimum  
–16, –32  
–2  
latches  
= 85Ω  
–2  
= Pin 1 to  
Pin 2  
NO. OF  
PAIRS  
A
–B1  
= Board  
lock, No  
housing  
(20,85) .821  
(24,05) .947  
(33,66) 1.325  
(52,86) 2.081  
–04  
–08  
–16  
–32  
–3  
CABLE  
ECDP–04  
ECDP–08  
ECDP–16  
ECDP–32  
CONNECTOR  
–L2  
= Double  
Vertical  
with  
latches  
(Wiring  
option –1  
& –2 only)  
= Pin 1 to  
Pin N-1  
HSEC8–109–XX  
HSEC8–113–XX  
HSEC8–125–XX  
HSEC8–149–XX  
OAL = Wire Length + (67,3) 2.65  
–4  
= Pin 1 to  
Pin N  
N-1  
Note:  
Cable shield construction  
N
leaves minor exposed edges.  
Users should consider whether  
this will affect the application in  
which the cable is to be used.  
Insulation may be required as  
needed.  
02  
–B1  
= Board  
lock, No  
housing  
A
Note:  
Cable lengths longer than  
40.00" (1 meter) are not  
supported with S.I. test data.  
–B2  
= Board  
lock, No  
housing  
02  
01  
–B2 (END 2)  
Note:  
(20,84)  
.820  
Verify part number and correct  
wiring scheme with Samtec’s  
Interactive Cable Builder at  
www.samtec.com/cable_  
builder/pitch.aspx  
N
–L1 (END 1)  
(6,27)  
.247  
(1,53)  
.060  
–L1 (END 2)*  
Note:  
*Same pinout for  
Some lengths, styles and  
options are non-standard,  
non-returnable.  
–B1 end 2 as –L1 end 2.  
WWW.SAMTEC.COM  

相关型号:

ECDP-04-03.75-B1-B1-2-2

Interconnection Device, ROHS COMPLIANT
SAMTEC

ECDP-04-03.75-L1-B1-2-1

Interconnection Device, ROHS COMPLIANT
SAMTEC

ECDP-04-03.75-N1-B2-4-1

Interconnection Device
SAMTEC

ECDP-08-03.75-B1-B1-2-2

Interconnection Device, ROHS COMPLIANT
SAMTEC

ECDP-08-03.75-L1-B1-2-1

Interconnection Device, ROHS COMPLIANT
SAMTEC

ECDP-08-03.75-N1-B1-2-1

Interconnection Device
SAMTEC

ECDP-08-03.75-N1-B1-2-2

Interconnection Device
SAMTEC

ECDP-08-03.75-N1-B2-4-1

Interconnection Device
SAMTEC

ECDP-16-03.75-B1-B1-2-1

Interconnection Device, ROHS COMPLIANT
SAMTEC

ECDP-16-03.75-B1-B1-2-2

Interconnection Device, ROHS COMPLIANT
SAMTEC

ECDP-16-03.75-L1-B1-2-1

Interconnection Device, ROHS COMPLIANT
SAMTEC

ECDP-16-03.75-N1-B2-4-1

Interconnection Device
SAMTEC