General Description  
Package --- TO-263  
A surface mount device added to 600V_L series.  
Realizes better space-saving in mounting on a printed circuit  
board by using a surface mount package (TO-263).  
Applications  
Continuous-current-mode PFC circuit.  
An output rectifier for SMPS, UPS, or DC-DC converters.  
A Flywheel diode for inverters and choppers.  
Features  
Surface mount package (TO-263)  
Low loss FRD (600 V_L series)  
Key Specifications  
Absolute maximum ratings  
Parameter  
Symbol Unit  
Rating  
600  
Die Structure: Silicon Planer Diode (FRD)  
Transient Peak Reverse Voltage  
Peak Reverse Voltage  
VRSM  
VRM  
V
V
A
A
600  
3
Average Forward Current  
Peak Surge Forward Current  
IF(AV)  
IFSM  
50  
Electrical characteristics  
Parameter  
Symbol Unit Rating  
Conditions  
Forward Voltage Drop  
VF  
IR  
V
1.75 max. IF=3A  
Reverse Leakage Current  
μA  
50 max. VR=VRM  
VR=VRM,  
100 max.  
Reverse Leakage Current  
Under High Temperature  
H•IR μA  
trr ns  
Tj=150°C  
IF=IRP=100mA  
90%Recovery point  
Reverse Recovery Time  
50 max.  
Sanken Electric Co.,Ltd.  
1/5  
D01-007JE-060113  
Ultrafast Recovery Diode  
MPL-1036S  
January, 2006  
§1. Absolute Maximum Ratings and Electrical Characteristics  
•Absolute Maximum Ratings  
Symbol  
VRSM  
VRM  
IF(AV)  
IFSM  
I2t  
Unit  
V
Rating  
600  
Conditions  
No.  
1
Parameter  
Transient Peak Reverse Voltage  
Peak Reverse Voltage  
Average Forward Current  
Peak Surge Forward Current  
I2t Limiting Value  
V
600  
2
A
3
3
A
50  
10msec. Half sine-wave, one shot  
4
A2S  
°C  
°C  
12.5  
5
1msec t 10msec  
Junction Temperature  
Storage Temperature  
-40 to +150  
-40 to+150  
6
Tj  
7
Tstg  
• Electrical Characteristics  
Parameter  
Forward Voltage Drop  
Reverse Leakage Current  
Symbol  
VF  
Unit  
V
Rating  
1.75 max.  
50 max.  
Conditions  
IF=3A  
No.  
1
VR=VRM  
2
IR  
µA  
Reverse Leakage Current Under  
High Temperature  
3
H•IR  
µA  
100 max.  
VR=VRM, Tj=150°C  
IF=IRP=100mA  
90% Recovery point  
Reverse Recovery Time  
Thermal Resistance  
50 max  
4
5
trr  
ns  
2.5 max.  
Between Junction and case  
Rth(j-c)  
°C/W  
Sanken Electric Co.,Ltd.  
2/5  
D01-007JE-060113  
Ultrafast Recovery Diode  
MPL-1036S  
January, 2006  
§2. Package information  
2-1 Package type, physical dimensions  
(3)  
(2) (1)  
(2) is connected to a heat sink.  
Unit: ㎜  
2-2 Marking  
Marking  
Part Number  
Type Name  
Polarity  
Lot number  
1st letter: Last digit of year  
2nd letter: Month From 1 to 9 for Jan. to Sep.,  
O for Oct., N for Nov., D for Dec.  
MPL-1036S  
L1036  
3rd letter: Day Week(Every month of 1st to 5th week)  
4th to 6th letter:  
Suffix No.  
Sanken Electric Co.,Ltd.  
3/5  
D01-007JE-060113  
Ultrafast Recovery Diode  
MPL-1036S  
January, 2006  
§3. Characteristics  
IF(AV) - PF  
10  
Tj=150°C  
8
6
4
2
0
t
T
t/T=1/6  
t/T=1/3,Sine-wave  
t/T=1/2  
DC  
0
1
2
3
Average Forward Current IF(AV) (A)  
§4. Derating  
Tc - IF(AV)  
VR=0 (V)  
3
DC  
t/T=1/3, Sine-wave  
t/T=1/6  
t/T=1/2  
2
1
0
Tj=150°C  
t
T
0
50  
100  
150  
Case Temperature Tc (°C)  
Sanken Electric Co.,Ltd.  
4/5  
D01-007JE-060113  
Ultrafast Recovery Diode  
MPL-1036S  
January, 2006  
CAUTION / WARNING  
The information in this publication has been carefully checked and is believed to be accurate; however, no  
responsibility is assumed for inaccuracies.  
Sanken reserves the right to make changes without further notice to any products herein in the interest of  
improvements in the performance, reliability, or manufacturability of its products.  
Before placing an order, Sanken advises its customers to obtain the latest version of the relevant information to verify  
that the information being relied upon is current.  
Application and operation examples described in this catalog are quoted for the sole purpose of reference for the use  
of the products herein and Sanken can assume no responsibility for any infringement of industrial property rights,  
intellectual property rights or any other rights of Sanken or any third party which may result from its use.  
When using the products herein, the applicability and suitability of such products for the intended purpose or object  
shall be reviewed at the users’ responsibility.  
Although Sanken undertakes to enhance the quality and reliability of its products, the occurrence of failure nd defect  
of semiconductor products at a certain rate is inevitable. Users of Sanken products are requested to take, at their own  
risk, preventative measures including safety design of the equipment or systems against any possible injury, death,  
fires or damages to the society due to device failure or malfunction.  
Sanken products listed in this catalog are designed and intended for the use as components in general purpose  
electronic equipment or apparatus (home appliances, office equipment, telecommunication equipment, measuring  
equipment, etc.). Before placing an order, the user’s written consent to the specifications is requested.  
When considering the use of Sanken products in the applications where higher reliability is required (transportation  
equipment and its control systems, traffic signal control systems or equipment, fire/crime alarm systems, various  
safety devices, etc.), please contact your nearest Sanken sales representative to discuss and obtain written confirmation  
of your specifications. The use of Sanken products without the written consent of Sanken in the applications where  
extremely high reliability is required (aerospace equipment, nuclear power control systems, life support systems, etc.)  
is strictly prohibited.  
Anti radioactive ray design is not considered for the products listed herein.  
This publication shall not be reproduced in whole or in part without prior written approval from Sanken.  
This is notification that you, as purchaser of the products/technology, are not allowed to perform any of the following:  
1. Resell or retransfer these products/technology to any party intending to disturb international peace and security.  
2. Use these products/technology yourself for activities disturbing international peace and security.  
3. Allow any other party to use these products/technology for activities disturbing international peace and security.  
Also, as purchaser of these products/technology, you agree to follow the procedures for the export or transfer of these  
products/technology, under the Foreign Exchange and Foreign Trade Law, when you export or transfer the  
products/technology abroad.  
Sanken Electric Co.,Ltd.  
5/5  
D01-007JE-060113  

相关型号:

MPL-12-12

Split Bobbin Power Transformer, 12VA,
BEL

MPL-12-15

Split Bobbin Power Transformer, 12VA,
BEL

MPL-6-12

Split Bobbin Power Transformer, 6VA,
BEL

MPL-6-15

Split Bobbin Power Transformer, 6VA,
BEL

MPL-SE2512-1R5

GENERAL PURPOSE INDUCTOR,
MPS

MPL-SE2512-2R2

GENERAL PURPOSE INDUCTOR,
MPS

MPL-SE2512-3R3

GENERAL PURPOSE INDUCTOR,
MPS

MPL-SE2512-4R7

GENERAL PURPOSE INDUCTOR,
MPS

MPL-SE2512-R68

GENERAL PURPOSE INDUCTOR,
MPS

MPL-SE5040-220

GENERAL PURPOSE INDUCTOR,
MPS

MPL015A2

Barometry (portable and desk-top) Weather Stations Industrial Equipment
FREESCALE

MPL015A2T1

Barometry (portable and desk-top) Weather Stations Industrial Equipment
FREESCALE