DSY2Y-S-212L-F [SANYOU]
Subminiature Signal Relay;型号: | DSY2Y-S-212L-F |
厂家: | Sanyou Relays |
描述: | Subminiature Signal Relay |
文件: | 总3页 (文件大小:59K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
version:V2.1
Subminiature
Signal Relay
SANYOU RELAYS
DSY2Y - Series
Relays for advanced technology
Features
● 2 transfer contact configuration.
● Small size and light weight for high density PCB mounting.
● 150mW type available.
Safety Approval
UL,C-UL File No.:E179745
TUV File No.:R50253080
CQC File No.:CQC02001002119
Contact Capacity
Model
DSY2Y
1A 120VAC
2A
Nominal switching capacity (res. load)
Max. switching current
Max. switching voltage
Max. switching power
277VAC
554VA
Characteristic Data
Silver alloy
Contact material
Initial contact resistance (at 6VDC 1A)
Operate time (at nominal volt.)
Release time (at nominal volt.)
Initial insulation resistance
100m Max.
7msec. Max.
4msec. Max.
100M Min.(DC500V)
AC750V,50/60Hz
Between open contacts(Standard):
1Min.
Between open contacts(High dielectric strength):
1Min.
1Min.
AC1,500V,50/60Hz
Initial dielectric strength
Between coil and contact(Standard):
AC1,000V,50/60Hz
1Min.
Between coil and contact(High dielectric strength):
AC1,800V,50/60Hz
10~55Hz at double amplitude of 1.5 mm
Functional
Destructive
Functional
Destructive
Mechanical
Vibration resistance
Shock resistance
10~55Hz at double amplitude of 1.5 mm
10G Min.
100G Min.
10,000,000
100,000
Endurance
(at 10,800 ops./h)
(at 1,800 ops./h)
(operations)
Electrical
Ambient temperature
Unit weight
-40℃~+85℃ (no condensation)
Approx. 4.6 g
(at 20℃)
Coil Data
Nominal
Nominal
operating
current
10% ( mA)
Coil
. Max
allowable
voltage
Pick-up
Drop-out
voltage
(Min.)
Nominal
operating
power
voltage
resistance
10% ( Ω)
voltage
(Max.)
(VDC)
3
50
60
7
5
30
167
240
540
960
1,500
11.5
13.8
20.8
27.7
34.6
41.8
55.2
6
25
75 % of
nominal
voltage
5 % of
nominal
voltage
Approx
.
9
16.6
12.5
10
0.15W
12
15
18
24
8
2,160
3,840
6.25
1/3
DSY2Y
(at 20℃)
Coil Data
Nominal
Nominal
operating
current
.Max
allowable
voltage
6
Nominal
operating
power
Coil
resistance
10% ( Ω)
45
Pick-up
voltage
(Max.)
Drop-out
voltage
(Min.)
voltage
(VDC)
3
10% ( mA)
66.6
40.0
33.3
22.2
16.6
13.3
5
125
10
6
180
12
18
9
405
0.2W
24
12
15
720
1,125
30
75 % of
nominal
voltage
5 % of
nominal
voltage
18
24
3
11
8.3
1,620
2,880
25
36
48
4.5
8
120.0
72.0
60.0
40.0
30.0
69
5
100
225
400
10
6
.Approx
14.5
18.5
9
0.36W
12
625
24.0
22
15
26.8
35.5
56
20.0
15.0
12.0
900
1,600
4,000
18
24
48
Approx.0.58W
Safety Approval Ratings
(Note:More detail of approval ratings,please refer to the safety certification)
Approval
File No.
TUV
CQC
UL/CUL
E179745
CQC02001002119
R50253080
0.5A 120VAC
1A 24VDC
1A 120VAC
2A 30VDC
Approved ratings
1A 125VAC
Ordering Information
Nomenclature
12
D
-F -XX
DSY2Y -S -2
Special Parameter:Nil-Standard type,
01-High dielectric strength(only 0.36W)
Letter or number-Special requirement
Insulation System:Nil-Standard, B-Class B, F-Class F
Coil Power:D-0.36W, L-0.20W, H-0.15W, Nil-0.58W
Coil Voltage (VDC):03, 05, 06, 09, 12, 15,18, 24, 48
Number of Poles:2-2 Poles
Protective Construction:S-Flux proofed, SH-Sealed type washable
Type Designation:DSY2Y
Outline Dimensions, Wiring Diagram, P.C. Board Layout (unit:mm)
8-Φ1
7.62
5.08 5.08
Wiring Diagram (bottom view)
P.C.B. Layout (bottom view)
Unless otherwise specified:
If dimension <1mm, tolerance: 0.2 mm;
If dimension 1~5mm, tolerance: 0.3 mm;
If dimension >5mm, tolerance: 0.4 mm.
Note: 1. Extended terminal dimension is dimension before soldering.
2. Tolerance of P.C.B. layout: 0.1 mm.
2/3
DSY2Y
Typical Applications
● Telecommunication equipment
● Computer peripherals
● Medical equipment
● Office equipment
● Security alarm system
Characteristic Curves
Max. Switching Power
Endurance Curve
100
1000V
AC Res. Load
30VDC Res. Load
30
10
100V
DC Res. Load
10V
120VAC
Res. Load
1
0
10mV
1
2
3
10uA
100mA
1A
10A
Contact Current(A)
Contact Current(A)
Disclaimer:
This datasheet is the customers' reference. All the specification are subject to change without notice.
We could not evaluate all the performance and all the parameters for every possible application.Thus the
user should in a right position to choose the suitable product for their own application.If there is any query,
please contact Sanyou for the technical service.However it is the user's responsibility to determine which
product should be used only.
Dongguan Sanyou Electrical appliance Co.,LTD,All rights of Sanyou to reserved
3/3
相关型号:
©2020 ICPDF网 联系我们和版权申明