SARF-S-136LM1PDC [SANYOU]
High Power Automotive Relay;型号: | SARF-S-136LM1PDC |
厂家: | Sanyou Relays |
描述: | High Power Automotive Relay |
文件: | 总4页 (文件大小:230K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
version:V2.0
High Power
Automotive Relay
SANYOU RELAYS
SARF-Series
Relays for advanced technology
Features
● 70A high switching capability.
● High operating temperature:125℃.
● 1Form A contact configuration.
● Dustproof and sealed type available.
● Transient suppression resistance or diode paralleled type
available.
Contact Capacity
Model
SARF
70A 14VDC (at 23℃)
50A 14VDC (at 85℃)
Nominal switching capacity (res. load)
Max. switching current
Max. switching voltage
Max. switching power
70A
50VDC
980W
Characteristic Data
Contact material
Silver alloy
20mΩ Max.
Initial contact resistance (at 6VDC 1A)
Operate time (at nominal volt.)
Release time (at nominal volt.)
Initial insulation resistance
10msec. Max.
ordinary type:7msec.Max. with resistor or diode type :15 msec. Max.
500MΩ Min.(DC500V)
Between open contacts:
Between coil and contact:
Functional
AC500V,50/60Hz
1Min.
1Min.
Initial dielectric strength
Vibration resistance
Shock resistance
AC500V,50/60Hz
10~55Hz at double amplitude of 1.5 mm
10~55Hz at double amplitude of 1.5 mm
Destructive
18G Min.
30G Min.
10,000,000
100,000
Functional
Destructive
(at 10,800 ops./h)
(at 600 ops./h)
Mechanical
Electrical
Endurance
(operations)
Ambient temperature
Unit weight
-40℃~+125℃ (no condensation)
Standard type:Approx. 36.0 g ;PCB type:Approx. 30.0g
Coil Data(at 20℃)
Nominal
Coil
Standard (D)
Nominal
operating
Nominal
operating
power
Max.
Allowable
voltage
Pick-up
voltage
(Max.)
Drop-out
voltage
(Min.)
Parallel
Equivalent
voltage
current
±10% (mA)
resistance resistance resistance
(VDC)
±10% (Ω)
22.5
90
(Ω)
(Ω)
6
12
24
36
6
266.67
133.33
66.67
---
---
.Approx
---
---
---
---
1.6W
360
150 % of
nominal
voltage
60 % of
10% of
44.44
810
---
---
nominal nominal
voltage voltage
266.67
133.33
66.67
22.5
90
20
180
.Approx
12
24
80
680
1.8W
360
320
2,700
1/4
SARF
Sensitivity (L)
Coil Data (at 20℃)
Nominal
Max.
Allowable
voltage
Nominal
operating
power
Nominal
Coil
Parallel
Equivalent
Pick-up
voltage
(Max.)
Drop-out
voltage
(Min.)
operating
voltage
current
resistance resistance resistance
(VDC)
6
±10% (Ω)
18
(Ω)
---
(Ω)
±10% (mA)
333.33
166.67
83.33
---
72
---
---
.Approx
2.0W
12
24
36
6
---
---
288
648
18
115 % of 60 % of
nominal nominal nominal
voltage voltage voltage
10% of
---
55.56
---
16
180
333.33
166.67
83.33
.Approx
2.2W
65
680
72
12
24
260
2,700
288
Ordering Information
Nomenclature
SARF -S - 1 12 D M 1 F R -XX
Special Parameter:Nil-Standard type,
Letter or number-Special requirement
Accessory Form:Nil-Without accessory, R-With resistor,
D-With diode DC-with diode
MountingType:Nil-w/t backrest, F-w/ backrest, P-PCB type
Contact Material:Nil-AgSnO2, 1-AgCdO
Contact Form:M-Form A
Coil Power:D-1.6W/1.8W, L-2.0W/2.2W
Coil Voltage (VDC):06, 12, 24, 36
Number of Poles:1-1 Pole
Protective Construction:Nil-Dust protected, S-Flux proofed
Type Designation:SARF
NOTES: 1) -15 means that the length of terminal outside of the case is 15 millimetre refering to
outline dimensions .
Outline Dimensions, Wiring Diagram, Mounting Holes (unit:mm)
With backrest type (standard)
With backrest type (-15)
17.9
8.4
17.9
8.4
86
86
30
87
30
87
85
10.5
85
10.5
55
55
2/4
SARF
Normal type (standard)
Normal type (-15)
(-15)
17.9
8.4
17.9
8.4
86
87
86
30
30
87
85
85
10.5
10.5
55
55
PCB type
Unless otherwise specified:
If dimension <1mm, tolerance: ±0.2mm;
If dimension 1~5mm, tolerance: ±0.3mm;
If dimension >5mm, tolerance: ±0.4mm.
Note: 1. Extended terminal dimension is dimension before
soldering.
2. Tolerance of m ounting holes:±0.1mm.
P.C.B. Layout
with diode(DC Type)
with risistor
with diode(D Type)
w/t accessory
87
87
87
87
86
85
86
85
86
85
86
85
30
30
30
30
R
Wiring Diagram (bottom view)
3/4
SARF
Typical Applications
● Cooling fan control, fuel pump control, heating control, automotive air conditioner, rear window
defogger, battery breaking device.
● Headlight or foglight control, electric power distribution, traction control system, ABS.
Characteristic Curves
Continuous coil voltage range
Max. Allowable load range
200
180
160
140
120
100
80
70
50
Max. Continuous coil voltage(D)
Max. Continuous coil voltage(L)
10
5
Operate voltage after
continuous energization
Initial operate voltage
1
5
20 304050
10
-40 -20
0
20
40
60
80
100 120
60
Contact voltage(VDC)
Ambient temperature(℃)
Disclaimer:
his datasheet i
e could not evaluate all t
T
s t he customers' r eference. All t
he performance and all t
he specification are subject t
o change without notice.
W
he parameters f or every possible application.Thus t
he
here i s any query,
o determine which
user s hould in a r ight position to choose the suitable product f
or t heir own application.If t
please contact Sanyou for t
he technical s
ervice.However i
t i s t he user's r esponsibility t
product s hould be used only.
D
ongguan Sanyou Electrical a
ppliance Co.,LTD,All r
ights of Sanyou to reserved
4/4
相关型号:
©2020 ICPDF网 联系我们和版权申明