SEV10 [SANYOU]
High Voltage DC Relay;Version:V1.1
SEV10
High Voltage DC Relay
Feature
SANYOURELAYS
Relays for advanced technology
●10 amps continuous carry,100 amps interrupte under
extreme condition.
●Hermetically sealed with hydrogen gas,the arc is not exposed.
Be able to use in explosive & harsh environments without
oxidation or contamination of contacts.Contacts' part meet
IP67 protection degree.
●Not position sensitive- can be mounted in any position for
ease of installation.
●RoHS compliant.
Contact Data
Parameters Table
Item
Information
1 Form A contact
10A
Item
Information
5×105 cycles
Mechanical life
Contact arrangement
Current rating
Insulation resistance
Between
1000MΩ(1000VDC)
3000VAC 1min. 10mA
4000VAC 1min. 10mA
Contact resistance
≤10mΩ(@6V 20A)
12VDC 0.5A
open contacts
Dielectric
strength
Between
contact and coil
Min.Switching load
Operate time
(at rated coil voltage)
Release time
(at rated coil voltage)
Max. Switching voltage
Max. Breaking current
Max. Switching power
≤30ms
≤10ms
1000VDC
100A,1000VDC,1cycle
10KW
196m/s2(20G)
490m/s2(50G)
Functional
Shock
resistance
500V type
Destructive
750V type
1×105 cycles
(10A,500VDC)
1×105 cycles
(10A,750VDC)
10Hz~500Hz 49m/s2(5G)
-40℃~85℃
Vibration resistance
Ambient temperature
Ambient humidity
5×104 cycles
(-10A,500VDC)
5×104 cycles
(-10A,750VDC)
Resistive
load
Electrical
life(1)
5%~95% RH
Approx.185g
7.5×104 cycles
(10A,1000VDC)
Weight
3×104 cycles
(-10A,1000VDC)
External dimension
66.8×44.5×36.85
10A:continuity
Coil Data(3)
Rated voltage(VDC)
Operation voltage(VDC)
Max. voltage(VDC)
15A:1h
20A:20min.
40A:30s
24
24
12
12
14
Load current
capacity(2)
28
60A:10s
Pick-up voltage(VDC)
≤18
≤9
100A:0.6s
Drop-out voltage(VDC)
Coil resistance(±10%)(Ω)
≥1.0
≥2.0
192
3
48
3
NOTES:
Operating power
(inrush,W)
(1)Ambient temperature:23℃,L/R≤1ms.
(2)Ambient temperature:23℃,4mm2
conductor.
Operating power
(stable,W)
3
3
(3)Other types of rated voltage,please
contact us.
1/3
SEV10
Ordering Information
Nomenclature
SEV 10 - □
M
□
□
Customer special code
Nil:No customer special requirement
Numbers or Letters:Customer special requirement
Coil voltage 12:12VDC
24:24VDC
Contact arrangement M:1 Form A
Voltage rating 750:12~750VDC
500:12~500VDC
Load current 10:10A
Type designation SEV
Packing quantity:1pcs inner carton, 60pcs outer carton
Outline Dimensions
Size
tolerance
±0.3
±0.5
Less than 10mm:
10 to 50mm:
More than 50mm:
±0.8
2/3
SEV10
Schematic Diagram
Installation Size Chart
NOTE:The contacts are polarized
NOTES
●Mounting Attention
1.When installing the relay, always use washers to prevent the screws from loosening.
2.Tighten each screw within the rated range given in the outline dimensions. Exceeding
the maximum torque may result in breakage.
3.Avoid mounting the relay in strong magnetic fields (near a transformer or magnet) or
close to an object that radiates heat.
●Electrical Life Attention
1.This relay is a DC high-voltage switch. In its final breakdown mode, it may lose the
ability to provide the proper cut-off.Therefore, do not exceed the indicated switching
capacity and life.
2.Please treat the relay as a product with limited life and replace it when necessary.
3.The contacts of the relay are polarized. Please follow instructions in the connection
schematic when connecting the contacts.
4.Be careful that foreign matter and oils and fats kind, don’t stick to the main terminal
parts because it is likely to cause terminal parts to give off unusual heat. Also, please
use the following specifications of conductor.
10A
20A
40A
60A
100A
150A
200A
250A
300A
Min. 2mm2 nominal cross-sectional area
Min. 3mm2 nominal cross-sectional area
Min. 10mm2 nominal cross-sectional area
Min. 15mm2 nominal cross-sectional area
Min. 35mm2 nominal cross-sectional area
Min. 45mm2 nominal cross-sectional area
Min. 60mm2 nominal cross-sectional area
Min. 80mm2 nominal cross-sectional area
Min. 100mm2 nominal cross-sectional area
●Coil Attention
1.Please note that when using a diode, the switching speed may decrease and cause a
reduction in cut-off performance, we recommend installing a surge protector varistor.
2.The pick-up voltage and drop-out voltage will change with ambient temperature,
please use rated voltage to make sure the relay operate reliable. Don’t exceed
maximum coil voltage.
3.The 250A and 300A types have built-in dedicated drive circuit, please drive the coil
with a quick startup (Built-in one-shot pulse generator circuit).
4.After the ON signal enters the 250A and 300A types, automatic coil current switching
occurs after approximately 0.1 seconds.Do not repeatedly turn it OFF within that 0.1
seconds interval, as doing so may damage the relay.
Disclaimer:
This datasheet is the customers’reference. All the specification are subject to change without notice.
We could not evaluate all the performance and parameters for every possible application. Thus the users should be in a
right position to choose the suitable product for their own application. If there is any query, please contact Sanyou
for technical service. However it is the users' responsibility to determine which product should be used only.
SANYOU CORPORATION LIMITED. All rights reserved by Sanyou.
3/3
相关型号:
©2020 ICPDF网 联系我们和版权申明