SEV150-750M48C2 [SANYOU]
High Voltage DC Relay;型号: | SEV150-750M48C2 |
厂家: | Sanyou Relays |
描述: | High Voltage DC Relay |
文件: | 总4页 (文件大小:155K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Version:V1.3
High Voltage DC Relay
SEV150
SANYOURELAYS
Relays for advanced technology
Feature
●150 amps continuous carry,1500 amps interrupte under
extreme condition.
●Hermetically sealed with hydrogen gas,the arc is not exposed.
Be able to use in explosive & harsh environments without
oxidation or contamination of contacts.Contacts' part meet
IP67 protection degree.
●Not position sensitive- can be mounted in any position for
ease of installation.
●RoHS compliant.
Contact Data
Parameters Table
Item
Information
1 Form A contact
150A
Item
Information
Mechanical life
5
105 cycles
Contact arrangement
Current rating
Insulation resistance
Between
1000MΩ(500VDC)
Contact resistance
≤1.5mΩ(@6V 20A)
12VDC 1A
3000VAC 1min 10mA
Dielectric
strength
open contacts
Between
contact and coil
Operate time
(at rated coil voltage)
Min.Switching load
4000VAC 1min 10mA
≤30ms
Max. Switching voltage
Max. Breaking current
Max. Switching power
900VDC
Release time
(at rated coil voltage)
1500A(450VDC,1 cycle)
≤10ms
196m/s2(20G)
490m/s2(50G)
10Hz~500Hz 49m/s2(5G)
-40℃~85℃
Functional
Shock
112.5KW
resistance
500V type
750V type
Destructive
500VDC,150A
750VDC,150A
Vibration resistance
Ambient temperature
3
103 cycles
1
103 cycles
Resistive
load
break only:
360VDC,75A
break only:
600VDC,75A
Electrical
life(1)
1
104 cycles
6
103 cycles
Ambient humidity
Weight
5%~95% RH
Approx.352g
2.5 104cycles
22.5VDC,τ=1ms
inrush 400A
2.5 104cycles
37.5VDC,τ=1ms
inrush 400A
steady 150A
steady 150A
Capacitive
load
make only:1cycle
360VDC,τ=1ms
inrush 1350A
External dimension
75mm 40mm 74.5mm
steady 150A
150A:continuity
CoilData(3)
180A:2h
300A:10min
600A:2min
Rated voltage(VDC)
Operation voltage(VDC)
Max. voltage(VDC)
24
24
48
48
12
12
16
Load current
capacity(2)
32
64
Pick-up voltage(VDC)
Drop-out voltage(VDC)
≤18
≤36
≤9
≥1.0
32
900A:30s
≥2.0
128
4.5
≥4.0
512
4.5
1500A:0.6s
Coil resistance( 10%)( Ω)
Operating power
NOTES:
4.5
(1)Ambient temperature:23℃,L/R≤1ms.
(2)Ambient temperature:23℃,45mm2
conductor.
(inrush,W)
Operating power
(stable,W)
4.5
4.5
4.5
(3)Other types of rated voltage,please
contact us.
1/4
SEV150
Ordering Information
Nomenclature
SEV 150- □ M □ □ □ □
Customer special code
Nil:No customer special requirement
Numbers or Letters:Customer special requirement
Load connection type
1:connect plate+external thread
2:internal thread
Coil connection type Nil:outgoing line
C:outgoing line+connector
Coil voltage 12:12VDC
24:24VDC
48:48VDC
Contact arrangement M:1 Form A
Voltage rating 750:12~750VDC
450:12~450VDC
Load current 150:150A
Type designation SEV
Packing quantity:1pcs inner carton, 20pcs outer carton
Outline Dimensions(Connect Plate+External Thread)
Size
tolerance
0.3
0.5
Less than 10mm:
10 to 50mm:
More than 50mm:
0.8
2/4
SEV150
Outline Dimensions(Internal Thread)
Size
tolerance
Less than 10mm:
10 to 50mm:
More than 50mm:
0.3
0.5
0.8
Coil Connection Type
C:Outgoing Line+Connector(Accessories)
3/4
SEV150
Installation Size Chart
Schematic Diagram
NOTE:The contacts are polarized
NOTES
●Mounting Attention
1.When installing the relay, always use washers to prevent the screws from loosening.
2.Tighten each screw within the rated range given in the outline dimensions. Exceeding
the maximum torque may result in breakage.
3.Avoid mounting the relay in strong magnetic fields (near a transformer or magnet) or
close to an object that radiates heat.
●Electrical Life Attention
1.This relay is a DC high-voltage switch. In its final breakdown mode, it may lose the
ability to provide the proper cut-off.Therefore, do not exceed the indicated switching
capacity and life.
2.Please treat the relay as a product with limited life and replace it when necessary.
3.The contacts of the relay are polarized. Please follow instructions in the connection
schematic when connecting the contacts.
4.Be careful that foreign matter and oils and fats kind, don’t stick to the main terminal
parts because it is likely to cause terminal parts to give off unusual heat. Also, please
use the following specifications of conductor.
10A
20A
40A
60A
100A
150A
200A
250A
300A
Min. 2mm2 nominal cross-sectional area
Min. 3mm2 nominal cross-sectional area
Min. 10mm2 nominal cross-sectional area
Min. 15mm2 nominal cross-sectional area
Min. 35mm2 nominal cross-sectional area
Min. 45mm2 nominal cross-sectional area
Min. 60mm2 nominal cross-sectional area
Min. 80mm2 nominal cross-sectional area
Min. 100mm2 nominal cross-sectional area
●Coil Attention
1.Please note that when using a diode, the switching speed may decrease and cause a
reduction in cut-off performance, we recommend installing a surge protector varistor.
2.The pick-up voltage and drop-out voltage will change with ambient temperature,
please use rated voltage to make sure the relay operate reliable. Don’t exceed
maximum coil voltage.
3.The 250A and 300A types have built-in dedicated drive circuit, please drive the coil
with a quick startup (Built-in one-shot pulse generator circuit).
4.After the ON signal enters the 250A and 300A types, automatic coil current switching
occurs after approximately 0.1 seconds.Do not repeatedly turn it OFF within that 0.1
seconds interval, as doing so may damage the relay.
Disclaimer:
This datasheet is the customers’reference. All the specification are subject to change without notice.
We could not evaluate all the performance and parameters for every possible application. Thus the users should be in a
right position to choose the suitable product for their own application. If there is any query, please contact Sanyou
for technical service. However it is the users' responsibility to determine which product should be used only.
SANYOU CORPORATION LIMITED. All rights reserved by Sanyou.
4/4