SEV60 [SANYOU]

High Voltage DC Relay;
SEV60
型号: SEV60
厂家: Sanyou Relays    Sanyou Relays
描述:

High Voltage DC Relay

文件: 总3页 (文件大小:487K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
VersionV1.0  
SEV60  
High Voltage DC Relay  
Feature  
SANYOURELAYS  
Relays for advanced technology  
60 amps continuous carry,600 amps interrupte under  
extreme condition.  
Hermetically sealed with hydrogen gas,the arc is not exposed.  
Be able to use in explosive & harsh environments without  
oxidation or contamination of contacts.Contacts' part meet  
IP67 protection degree.  
Not position sensitive- can be mounted in any position for  
ease of installation.  
RoHS compliant.  
Contact Data  
Parameters Table  
Item  
Information  
1 Form A contact  
60A  
Item  
Information  
5×105 cycles  
Mechanical life  
Contact arrangement  
Current rating  
Insulation resistance  
Between  
1000MΩ(500VDC)  
Contact resistance  
1.5mΩ(@6V 20A)  
3000VAC 1min 10mA  
4000VAC 1min 10mA  
open contacts  
Dielectric  
strength  
Between  
contact and coil  
Min.Switching load  
Max. Breaking current  
Max. Switching power  
150VDC  
Operate time  
(at rated coil voltage)  
Release time  
(at rated coil voltage)  
600A150VDC1cycle)  
30ms  
10ms  
9KW  
1×105 cycles,(60A,24VDC)  
196m/s220G)  
490m/s250G)  
Functional  
Shock  
resistance  
4×104 cycles,(60A,48VDC)  
2×104 cycles,(60A,72VDC)  
1×104 cycles,(60A,150VDC)  
60Acontinuity  
Destructive  
Electrical  
life(1)  
Resistive  
load  
10Hz~500Hz 49m/s25G)  
-40℃~85℃  
Vibration resistance  
Ambient temperature  
Ambient humidity  
5%~95% RH  
Approx.195g  
Weight  
90A1h  
120A20min  
240A30s  
360A1s  
Load current  
capacity(2)  
External dimension  
76.6×46×36.85  
Coil Data3)  
Rated voltage(VDC)  
Operation voltage(VDC)  
Max. voltage(VDC)  
24  
24  
12  
12  
16  
32  
Pick-up voltage(VDC)  
≤18  
≤9  
NOTES:  
Drop-out voltage(VDC)  
Coil resistance(±10%)(Ω)  
≥1.0  
≥2.0  
192  
3
1)Ambient temperature:23℃,L/R1ms.  
2Ambient temperature:23℃,15mm2  
conductor.  
3Other types of rated voltage,please  
contact us.  
48  
3
Operating power  
(inrushW)  
Operating power  
(stableW)  
3
3
1/3  
SEV60  
Ordering Information  
Nomenclature  
SEV 60 - □ M □ □  
Customer special code  
NilNo customer special requirement  
Numbers or LettersCustomer special requirement  
Coil voltage 1212VDC  
24:24VDC  
Contact arrangement M1 Form A  
Voltage rating 15012~150VDC  
Load current 60:60A  
Type designation SEV  
Outline Dimensions(Standard Type)  
Size  
tolerance  
±0.3  
±0.5  
Less than 10mm:  
10 to 50mm:  
More than 50mm:  
±0.8  
2/3  
SEV60  
Schematic Diagram  
Installation Size Chart  
NOTE:The contacts are polarized  
NOTES  
Mounting Attention  
1.When installing the relay, always use washers to prevent the screws from loosening.  
2.Tighten each screw within the rated range given in the outline dimensions. Exceeding  
the maximum torque may result in breakage.  
3.Avoid mounting the relay in strong magnetic fields (near a transformer or magnet) or  
close to an object that radiates heat.  
●Electrical Life Attention  
1.This relay is a DC high-voltage switch. In its final breakdown mode, it may lose the  
ability to provide the proper cut-off.Therefore, do not exceed the indicated switching  
capacity and life.  
2.Please treat the relay as a product with limited life and replace it when necessary.  
3.The contacts of the relay are polarized. Please follow instructions in the connection  
schematic when connecting the contacts.  
4.Be careful that foreign matter and oils and fats kind, don’t stick to the main terminal  
parts because it is likely to cause terminal parts to give off unusual heat. Also, please  
use the following specifications of conductor.  
10A  
20A  
40A  
60A  
100A  
150A  
200A  
250A  
300A  
Min. 2mm2 nominal cross-sectional area  
Min. 3mm2 nominal cross-sectional area  
Min. 10mm2 nominal cross-sectional area  
Min. 15mm2 nominal cross-sectional area  
Min. 35mm2 nominal cross-sectional area  
Min. 45mm2 nominal cross-sectional area  
Min. 60mm2 nominal cross-sectional area  
Min. 80mm2 nominal cross-sectional area  
Min. 100mm2 nominal cross-sectional area  
Coil Attention  
1.Please note that when using a diode, the switching speed may decrease and cause a  
reduction in cut-off performance, we recommend installing a surge protector varistor.  
2.The pick-up voltage and drop-out voltage will change with ambient temperature,  
please use rated voltage to make sure the relay operate reliable. Don’t exceed  
maximum coil voltage.  
3.The 250A and 300A types have built-in dedicated drive circuit, please drive the coil  
with a quick startup (Built-in one-shot pulse generator circuit).  
4.After the ON signal enters the 250A and 300A types, automatic coil current switching  
occurs after approximately 0.1 seconds.Do not repeatedly turn it OFF within that 0.1  
seconds interval, as doing so may damage the relay.  
Disclaimer:  
This datasheet is the customersreference. All the specification are subject to change without notice.  
We could not evaluate all the performance and parameters for every possible application. Thus the users should be in a  
right position to choose the suitable product for their own application. If there is any query, please contact Sanyou  
for technical service. However it is the users' responsibility to determine which product should be used only.  
SANYOU CORPORATION LIMITED. All rights reserved by Sanyou.  
3/3  

相关型号:

SEV60-150M12

High Voltage DC Relay
SANYOU

SEV60-150M24

High Voltage DC Relay
SANYOU

SEXO-55G03IFREQ-OUT20

ECL 10KH Output Clock Oscillator, 25MHz Min, 200MHz Max
CTS

SEXO-55G142CFREQ-OUT20

ECL 10KH Output Clock Oscillator, 25MHz Min, 200MHz Max
CTS

SEXO-65G142IFREQ-OUT16

ECL 100K Output Clock Oscillator, 25MHz Min, 130MHz Max
CTS

SEXO55G0-1I-SERIES

Micro Peripheral IC
CTS

SEXO55G0-2I-SERIES

Micro Peripheral IC
CTS

SEXO55G0-4I-SERIES

Micro Peripheral IC
CTS

SEXO55G02C25.0MHZ

Micro Peripheral IC
CTS

SEXO55G02I125.0MHZ

Micro Peripheral IC
CTS

SEXO55G03I25.0MHZ

Micro Peripheral IC
CTS

SEXO55G04C125.0MHZ

Micro Peripheral IC
CTS