SLC-S-109DMK1-G-P-B 概述
Miniature High Power Relay
SLC-S-109DMK1-G-P-B 数据手册
通过下载SLC-S-109DMK1-G-P-B数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载version:V3.3
Miniature High
Power Relay
SANYOU RELAYS
SLC-Series
Relays for advanced technology
Features
Miniature relay with high switching capability:30A.
Contact form: Form A, Form B or 1Form C.
●
●
●
Special type of 4000VAC dielectric strength and 6000V surge
voltage (1.2/50uS) between coil and contact available.
Protection quick connect terminal type available.
●
●
Satisfy IEC60335-1product is available.
Safety Approval
UL,C-UL File No.:E190598
R50143450
TUV File No.:
CQC File No.:CQC02001002109
VDE File No.: 40036707
Contact Capacity
SLC -DM
30A 250VAC
30A
SLC -DB
15A 250VAC
20A
SLC -D
Model
Nominal switching capacity (res. load)
20A/10A 250VAC
20A
Max. switching current
Max. switching voltage
Max. switching power
250VAC
7,500VA
250VAC
250VAC
5,000VA
5,000VA
Characteristic Data
Contact material
Silver alloy
50mΩ Max.(1A 6VDC)
Initial contact resistance (at 6VDC 1A)
Operate time (at nominal volt.)
Release time (at nominal volt.)
Initial insulation resistance
15msec. Max.(no diode)
10msec. Max.(no diode)
100MΩ Min.(DC500V)
Between open contacts:
Between coil and contact:
Functional
AC1,500V,50/60Hz
1min.
Initial dielectric strength
Vibration resistance
Shock resistance
AC2,500V,50/60Hz 1min.(AC4KV available)
10~55Hz at double amplitude of 1.5 mm
10~55Hz at double amplitude of 1.5 mm
Destructive
10G Min.
Functional
Destructive
100G Min.
(at 10,800 ops./h)
Mechanical
Electrical
10,000,000 cycles(at room temperature)
100,000 cycles(at room temperature)
Endurance
(operations)
(at 360 ops./h)
Ambient temperature
Unit weight
-40℃~+105℃ (no condensation)
Approx.31.0g
Coil Data(a
t
20℃)
Nominal
operating
current
10% ( mA)
Drop-out
Max.
allowable
voltage
Coil
Nominal
operating
power
Nominal
voltage
(VDC)
Pick-up
resistance
10% ( Ω)
voltage
(Min.)
voltage
(Max.)
5
6
27
40
180.00
150.00
100.00
75.00
60.00
50.00
37.50
18.75
8.20
9
90
12
15
18
24
48
110
160
130 % of
nominal
voltage
75% of
nominal
voltage
5 % of
nominal
voltage
250
0.90W
360
640
2,560
13,400
1/4
SLC
Safety Approval Ratings
(Note:More detail of approval ratings,please refer to the safety certification)
VDE
Approval
File No.
TUV
UL/CUL
CQC
R50143450
CQC02001002109
40036707
E190598
Form A:
40A 277VAC, Resistive; 15A 240VAC ;
30A 240VAC, Resistive/General Use;
1-1/2HP 240VAC;3/4 HP 120VAC;
30A 120VAC, Resistive/General Use;
Pilot duty: 470 VA, 240VAC;
Electronic Ballast: 10A 277VAC /120VAC;
Form B:
TV-8 120VAC ;
Form A:
Form A:
30A 120VAC, General Use;
30A 240VAC
30A 250VAC
20A 240VAC, General Use;
20A 120VAC, Resistive;
Making: 80A 250VAC(300ms)
Breaking:20A 250VAC
Form B:
30A 250VAC,NO
Form B:
10A 240VAC, Resistive/General Use;
Pilot duty: 275VA, 240VAC;
Approved
ratings
20A 250VAC,CO(test NO)
10A 250VAC,CO(test NC)
15A 250VAC
Electronic Ballast: 5A, 277VAC/120VAC;
1/2HP 240VAC;1/4HP 120VAC;
Form C:
20A/10A 250VAC
15A 240VAC
Form C: N.O.
N.C.
Form C:
30A 240/120VAC,Resistive
20A/10A 240VAC
30A 240/120VAC,General Use 20A 240/120VAC, Resistive
20A 240VAC, Resistive
10A 240VAC, Resistive
1-1/2HP 240VAC
20A 240/120VAC,General Use
10A 240VAC, Resistive
1/2HP 240VAC
3/4HP 125/120VAC
TV-8 120VAC
1/4HP 125/120VAC
TV-3 120VAC
20A 240VAC, General Use 10A 240VAC, General Use
Pilot Duty: 470VA 240VAC Pilot Duty: 275VA 240VAC
Electronic Ballast:
Electronic Ballast:
10A 277VAC/120VAC
5A 277VAC/120VAC
(1) The above-mentioned unspecified temperature ratings, means that the ambient temperature is room temperature.
(2) Only some typical ratings are listed above. Each rating’s test condition is different, so the electrical endurance will be different.
If more details are required, please contact us.
(3) For sealed type testing, please open the ventilation hole of case before test.
Ordering Information
Nomenclature
-
-
K 1 - G
P F
-
XX
SLC - S - 1 12 D
M
Special Parameter:Nil-Standard type,
Letter or number-Special requirement
Insulation System:Nil-Standard, B-Class B, F-Class F
COM Flat quick-connect terminals:
Nil- Yoke and flat quick-connect terminal is one part;
P-Yoke rivet flat quick-connect terminal only for SLC-K
Paraneter sign:Nil-Standard,G-High contact load,Double-layer spring,Ø5.0 Contact
Contact Material:Nil-AgSnO2, 1-AgCdO
Terminal position: Nil-COM terminal and NC/NO terminal on the same side
K-COM terminal and NC/NO terminal on the opposite side
Contact Form:Nil-Form C, B-Form B, M-Form A
Coil Power:D-0.90W
Coil Voltage (VDC):05, 06, 09, 12, 15, 18, 24, 48, 110
Number of Poles:1-1 Pole
Protective Construction:S-Flux proofed, SH-sealed type washable
Type Designation:SLC
Outline Dimensions, Wiring Diagram, P.C. Board Layout (unit:mm)
2/4
2
SLC
SLC
Unless otherwise specified:
If dimension <1mm, tolerance: 0.2 mm;
If dimension 1~5mm, tolerance: 0.3 mm;
If dimension >5mm, tolerance: 0.4 mm.
Note: 1. Extended terminal dimension is
dimension before soldering.
2. Tolerance of P.C.B. Layout: 0.1 mm.
SLC-K
bottom view
(top view)
(top view)
(bottom view)
(top view)
(bottom view)
(bottom view)
SLC Wiring Diagram
(top view)
(bottom view)
(top view)
(bottom view)
(bottom view)
(top view)
SLC-KWiring Diagram
P.C.B Layout (Bottom view)
3/4
SLC
Typical Applications
● Car
● Heater and ventilation equipment
● Home appliances
● Air conditioner
Characteristic Curves
Coil Temp. Rise
Max. Switching Power
Endurance Curve
110
100
100
30
100
1a
40
1a
90
80
30 1c(NO)
1b
1c(NC)
10
10
20
15
1c(NO)
1c(NC)
1b
70
30A
25A
20A
60
AC
load
1
50
15A
DC
load
40
0A
0
1
80 90 100 110 120 130 140 150 160
10
100 200
1000
0
10
20
30
40
Percentage of Nominal Coil Voltage
Contact Voltage(V)
Contact Current(A)
Note: If you choose the sealed type, before using, please remove the convex platform at the top of the case to ensure the
as shown in the following diagram :
normal performance of the relay after the completion of a PCB operations. they are
convex platform
convex platform
SLC-K
with convex platform
SLC
without convex platform
Disclaimer:
This datasheet is the customers' reference. All the specification are subject to change without notice.
We could not evaluate all the performance and all the parameters for every possible application.Thus the user should
in a right position to choose the suitable product for their own application.For sealed relays after installation and cleaning,
please open the vent hole on the case before use.If there is any query,please contact Sanyou for the technica service.
However it is the user's responsibility to determine which product should be used only.
Sanyou Corporation Limited ,All rights of Sanyou to reserved
4/4
SLC-S-109DMK1-G-P-B 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
SLC-S-109DMK1-G-P-F | SANYOU | Miniature High Power Relay | 获取价格 | |
SLC-S-1110DBK1-G-P-B | SANYOU | Miniature High Power Relay | 获取价格 | |
SLC-S-1110DBK1-G-P-F | SANYOU | Miniature High Power Relay | 获取价格 | |
SLC-S-1110DMK1-G-P-B | SANYOU | Miniature High Power Relay | 获取价格 | |
SLC-S-1110DMK1-G-P-F | SANYOU | Miniature High Power Relay | 获取价格 | |
SLC-S-112DBK1-G-P-B | SANYOU | Miniature High Power Relay | 获取价格 | |
SLC-S-112DBK1-G-P-F | SANYOU | Miniature High Power Relay | 获取价格 | |
SLC-S-112DMK1-G-P-B | SANYOU | Miniature High Power Relay | 获取价格 | |
SLC-S-112DMK1-G-P-F | SANYOU | Miniature High Power Relay | 获取价格 | |
SLC-S-115DBK1-G-P-B | SANYOU | Miniature High Power Relay | 获取价格 |
SLC-S-109DMK1-G-P-B 相关文章
- 2024-09-20
- 5
- 2024-09-20
- 8
- 2024-09-20
- 8
- 2024-09-20
- 6