SLE-SH-124DM1-B [SANYOU]
Photovoltaic Relay;型号: | SLE-SH-124DM1-B |
厂家: | Sanyou Relays |
描述: | Photovoltaic Relay |
文件: | 总3页 (文件大小:157K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
version:V1.5
Photovoltaic Relay
SANYOU RELAYS
SLE-Series
Relays for advanced technology
Features
●
●
●
Miniature relay with high switching capability:35A.
Contact form:Form A,contact Gap>1.8mm .
4000VAC dielectric strength high and 6000V surge
voltage (1.2/50 uS) between coil and contact .
Product in accordance to IEC60335-1 and PTI>=325.
The appliance is able to meet VDE V 0126-1-1.
EN61095:AC7a at 85℃.
●
●
●
Safety Approval
UL,C-UL File No.:E190598
VDE File No.:40036707
CQC File No.:CQC02001002109
CCC File No.:2017010304978127
CE File No.:GE170305005551-A1
Contact Capacity
Model
SLE-DM
Nominal switching capacity (res. load)
Max. switching current
Max. switching voltage
Max. switching power
35A 277VAC
35A
277VAC
9,695VA
Charateristic Data
Contact material
Silver alloy
50mΩ Max.(1A 6VDC)
18msec. Max. (no diode)
Initial contact resistance (at 6VDC 1A)
Operate time (at nominal volt.)
Release time (at nominal volt.)
Initial insulation resistance
15msec. Max. (no diode)
100MΩMin.(DC500V)
Between open contacts:
Between coil and contact:
AC2,500V,50/60Hz 1min.
Initial dielectric strength
AC4,000V,50/60Hz 1min.
10~55Hz at double amplitude of 1.5 mm
10~55Hz at double amplitude of 1.5 mm
Destructive
Functional
Vibration resistance
Shock resistance
Destructive
Functional
100G Min.
10G Min.
5,000,000 cycles
at room temperature
Mechanical
(at 7,200 ops./h)
Endurance
(operations)
30,000 cycles(the ventilation hole open)
at room temperature
(at 360 ops./h)
Electrical
Ambient temperature
Unit weight
-40℃~+85℃ (no condensation)
Approx. 30.0g
CoiDatal (at 20
℃)
Nominal
operating
current
Coil
Pick-up
voltage
(Max.)
Drop-out
voltage
(Min.)
Max.
allowable
voltage
Nominal
voltage
(VDC)
Nominal
operating
power
resistance
10% ( Ω)
10% ( mA)
130 % of
nominal
voltage
75 % of
nominal
voltage
5 % of
nominal
voltage
187.50
93.75
64
12
24
2.25W
256
Note:The coil voltage can reduce to 40% ... 50% of the rated coil voltage after the relay's coil have energized
with the rated coil voltage more than 50 ms。
1/3
1/3
SLE
Safety Approval Ratings
(Note:More detail of approval ratings,please refer to the safety certification)
Approval
UL/CUL
CQC
CQC02001002109 2017010304978127 CE170305005551-A1
VDE
CCC
CE
File No.
40036707
E190598
35A 125/250/277VAC
Approved
ratings
Resistive
35A 125/250/277VAC
35A 125/250VAC/277VAC
AC-1,Ie:40A,Ue: AC230V
AC-1,Ie:40A,Ue: AC230V
Resistive
AC-7a
35A 125/250/277VAC
COSΦ=0.8
(1) The above-mentioned unspecified temperature ratings, means that the ambient temperature is room temperature.
(2) Only some typical ratings are listed above. Each rating’s test condition is different, so the electrical endurance will be different.
If more details are required, please contact us.
(3) For sealed type testing, please open the ventilation hole of case before test.
Ordering Information
Nomenclature
M
SLE -S - 1 12 D
1 -F -XX
Special Parameter:Nil-Standard type,
Letter or number-Special requirement
Insulation System:Nil-Standard, B-Class B, F-Class F
Contact Material:Nil-AgSnO
Contact Form:M-Form A
2, 1-AgNi
Coil Power:D-2.25W
Coil Voltage (VDC):12, 24
Number of Poles:1-1 Pole
Protective Construction:S-Flux proofed
SH-Sealed type washable
Type Designation:SLE
Outline Dimensions, Wiring Diagram, P.C. Board Layout (unit:mm)
2/3
bottom view
Unless otherwise specified:
If dimension <1mm, tolerance: 0.2 mm;
If dimension 1~5mm, tolerance: 0.3 mm;
If dimension >5mm, tolerance: 0.4 mm.
Note: 1. Extended terminal dimension is dimension
before soldering.
2. Tolerance of P.C.B. layout: 0.1 mm.
1/3
2/3
SLE
Wiring Diagram (bottom view)
P.C.B. Layout (bottom view)
Typical Applications
●
Photovoltaic controller,Charging pile,New energy automobile
Characteristic Curves
Max. Switching Power
Endurance Curve
100
30
100
1a
40
30
1a
10
20
15
10
1
AC load
1
0
10
20
30
40
10
100 200
1000
Contact Voltage(V)
Contact Current(A)
Note: If you choose the sealed type, before using, please remove the convex platform at the top of the case to ensure the
normal performance of the relay after the completion of a PCB operations. they are as shown in the following diagram:
convex platform
with convex platform
without convex platform
Disclaimer:
This datasheet is the customers' reference. All the specification are subject to change without notice.
We could not evaluate all the performance and all the parameters for every possible application.Thus the user should
in a right position to choose the suitable product for their own application.For sealed relays after installation and cleaning,
please open the vent hole on the case before use.If there is any query,please contact Sanyou for the technica service.
However it is the user's responsibility to determine which product should be used only.
Dongguan Sanyou Electrical appliance Co.,LTD,All rights of Sanyou to reserved
3/3
相关型号:
©2020 ICPDF网 联系我们和版权申明