SMF-SH-148DMH1-F [SANYOU]
Miniature Power Relay;型号: | SMF-SH-148DMH1-F |
厂家: | Sanyou Relays |
描述: | Miniature Power Relay |
文件: | 总3页 (文件大小:92K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
version: V2.2
Miniature
Power Relay
SANYOU RELAYS
SMF- Series
Relays for advanced technology
Features
● High contact capability:16 switching capability
● Small, Height only 15.7.mm
● Vertical or Horizontal quick terminal output
● Creepage distance :10 mm,IP/OP 5,000V
● Withstand surge voltage of 10KV
● Compliance with IEC 60335-1 GWIF850℃/GWIT775℃
CTI>=250V
● Ambient temperature range -40℃~105℃
● Compliance with RoHS and the requirements for
White Goods
Satisfice IEC60335-1 product is available.
●
●
Satisfice IEC60079-15 product is available.
Safety Approval
UL,C-UL File No.:E179745
CQC File No.:CQC13002089403
VDE File No.: 40031353
Contact Capacity
Model
SMF -1Pole NO
16A 277VAC
20A
SMF -1Pole NC
Nominal switching capacity (res. load)
16A 277VAC
20A
Max. switching current
Max. switching voltage
Max. switching power
277VA C
277VA C
4,432VA
4,432VA
Chara
Contact material
cteristic
Data
Silver alloy
Initial contact resistance at ( VD6C A 1
Operate time (at nominal volt . )
Release time (at nominal volt . )
)
100mΩMax.
15msec. Max.
10msec. Max.
100MΩMin.(DC500V)
Initial insulation resistance
Between open contacts:
Between coil and contact:
AC1000V,50/60 Hz
1min.
1min.
Initial dielectric strength
AC5000V,50/60 Hz
AC Hz Min
2500 ,50/60 1
Between contact sets:
V
10~55 Hz at double amplitude of 1.5 mm
10~55 Hz at double amplitude of 1.5 mm
10G Min.
Functional
Destructive
Destructive
Functional
Vibration resistance
Shock resistance
100G Min.
5,000,000cycles
(at 10,800 ops./h)
Mechanical
Electrical
Endurance
(operations )
100,000 cycles
(at 360 ops./h)
-40℃~+105℃ ( no condensation)
Ambient temperature
Unit weight
Approx. 15.5g
1/3
SMF
Coil Data
(
at 2 0℃)
Nominal
operating
current
coil
resistance
Nominal
voltage
(VDC)
5
Max.
allowable
voltage
Nominal
operating
power
Pick-up
voltage
(Max.)
Drop-out
voltage
(Min.)
% (Ω)
1 0% ( mA)
63
90
81.00
67.00
45.00
33.00
26.00
22.00
17.00
8.00
6
203
9
360
12
150 % of
nominal
voltage
75 % of
nominal
voltage
5 % of
nominal
voltage
0.40W
562
15
810
18
(Approx . )
1440
5,760
8,570
28,800
24
48
60
6.70
110
3.60
Safety Approval Ratings
(Note:More detail of approval ratings,please refer to the safety certification)
Approval
UL/CUL
CQC
VDE
CQC13002089403
File No.
40031353
E179745
16A 277VAC
16A 277VAC
Approved ratings
16A 277VAC
Ordering Information
Nomenclature
SMF -S - 1 12
D
M
H
1 -
F
XX
Special Parameter:Nil-Standard type,
-
Letter or number Special requirement
Insulation System:Nil-Standard, B-Class B, F-Class F
Contact Material:Nil-AgNi, 1-AgSnO2
V:Vertical quick terminal
Contact Capacity:
H:Horizontal quick terminal
Contact Form
Coil Power:D-0. 4W
Coil Voltage VDC): 05, 06, 09, 12,15, 18, 24, 48, 60.110
:
B
-
Form B Form A
, M-
(
Number of Poles:1-1 Pole
Protective Construction:S-Flux proofed
SH-Sealed type washable
Type Designation:SMF
2/3
SMF
Outline Dimensions Wiring Diagram ,P.C.Board Layout (unit:mm)
(
)
*
(
)
*
Vertical quick terminal
Horizontal quick terminal
1B Wiring Diagram( bottom view)
unless otherwise specified:
1A Wiring Diagram(bottom view)
if dimension < 1mm,tolerance: 0 .2mm
if dimension 1~5mm,tolerance : 0 .3mm
if dimension > 5mm,tolerance: 0 .4mm
Note:1.Extended terminal dimension is
dimension before soldering.
2.Tolerance of P.C.B Layout: 0 .1mm
1A/1 B P. C. B Layo(ut bottom vie)w
Typical Appliances
home appliances,washing machine,air conditioner,microwave oven
audio equipment ,monitor,industrial control equipment,instrument,etc.
Characteristic Curves
Temperature Range of Coil Operation
Endurance Curve
Max. Switching Power
B
A
16A 277VAC
16A 277VAC
contact voltage(V)
breaking capacity(kAV )
ambient temperature
Disclaimer:
This datasheet is the customers' reference. All the specification are subject to change without notice.
We could not evaluate all the performance and all the parameters for every possible application.Thus the user should
in a right position to choose the suitable product for their own application.For sealed relays after installation and cleaning,
please open the vent hole on the case before use.If there is any query,please contact Sanyou for the technica service.
However it is the user's responsibility to determine which product should be used only.
Dongguan Sanyou Electrical appliance Co., LTD, All rights of Sanyou to reserved
3/3
相关型号:
©2020 ICPDF网 联系我们和版权申明