SRDI-SH-124D2-F [SANYOU]

Miniature Power Relay;
SRDI-SH-124D2-F
型号: SRDI-SH-124D2-F
厂家: Sanyou Relays    Sanyou Relays
描述:

Miniature Power Relay

文件: 总4页 (文件大小:95K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
version:V3.3  
Miniature  
Power Relay  
SANYOU RELAYS  
SRDI-Series  
Relays for advanced technology  
Features  
●High contact capability: 12A switching capability.  
●Low coil power consumption, low price.  
●Microminiature relay, standard PCB terminal.  
Compliance EU RoHS and the requirement of white home appliances.  
Compliance with IEC60335-1 GWIF 850℃/GWIT 775℃ and CTI>=250V.  
●Impulse withstand voltage≥6000V product is available.  
●Satisfy IEC60079-15 product is available  
.
Safety Approval  
UL,C-UL File No.:E190598  
VDE File No.: 40034479  
CQC File No.:CQC02001002126  
Contact Capacity  
Model  
SRDI -DM  
10A 250VAC  
15A  
SRDI -D  
SRDI-DB  
7A 250VAC  
12A  
Nominal switching  
capacity (res. load)  
NO10A 250VAC  
NO/NC7A 250VAC  
12A  
Max. switching current  
Max. switching voltage  
Max. switching power  
277VAC  
2,770VA  
277VAC  
2,770VA  
277VAC  
1,939VA  
Characteristic Data  
Contact material  
silver alloy  
Initial contact resistance (at 6VDC 1A)  
100mΩ Max. (1A 6VDC)  
8msec. Max. (no diode)  
5msec. Max. (no diode)  
100MΩ Min. (DC500V)  
Operate time (at nominal volt.)  
Release time (at nominal volt.)  
Initial insulation resistance  
Between open contactsAC 750V,50/60Hz 1min.  
Between coil and contact: standard product AC 2,500V,50/60Hz 1min  
Initial dielectric strength  
product with suffix"-6" : AC3000V,50/60Hz 1min  
Between coil and contactstandard product 4800V 1.2/50us  
6000V 1.2/50us  
Impulse withstand voltage  
product with suffix"-6" ≥  
10~55Hz at double amplitude of 1.5 mm  
10~55Hz at double amplitude od 1.5 mm  
10G Min.  
Function  
Destructive  
Function  
Vibration resistance  
Shock resistance  
100G Min.  
Destructive  
(at 10,800ops./)  
Mechanical  
10,000,000 (at room temperature)  
100,000 (at room temperature)  
Endurance  
(operations)  
(at 360ops./)  
Electrical  
Ambient temperature  
Unit weight  
-40℃~+85℃(no condensation)  
Please contact us if your working condition is 105℃  
Approx.8.5g  
1/4  
SRDI  
(at 20℃)  
Coil Data  
Nominal  
operating  
current  
Drop-out  
voltage  
(Min.)  
Max.  
allowable  
voltage  
Pick-up  
voltage  
(Max.)  
Nominal  
voltage  
(VDC)  
Nominal  
Coil  
operating  
power  
resistance  
10% ( Ω)  
10% ( mA)  
25  
70  
3
5
120.00  
71.42  
60.00  
40.00  
30.00  
24.00  
20.00  
15.00  
7.50  
6
100  
9
225  
130 % of  
nominal  
voltage  
75 % of  
nominal  
voltage  
5 % of  
nominal  
voltage  
12  
15  
18  
24  
48  
60  
400  
0.36W  
625  
900  
1,600  
6,400  
10,000  
6.00  
Safety Approval Ratings  
(Note:More detail of approval ratings,please refer to the safety certification)  
UL/CUL  
Approval  
File No.  
CQC  
VDE  
E190598  
CQC02001002126  
40034479  
contact code 2(Form C) or Nil(Form A or Form B):  
12A 125VACResistive,NO&NC  
15A 125VACResistive,NO  
Contact code 2 o rNil:  
10A 250VAC(Form C,NO)  
7A 250VAC(Form C,NO)  
6A 250VAC(Form CNC)  
7A 250VAC  
5A 240VAC  
Approved  
ratings  
10A 250VACResistive,NO  
7A 250VACGeneral use,NO&NC  
3A 125VACGeneral Use,NO&NC  
10A/6A 250VAC General use NO/NC  
10A/6A 125VAC General use NO/NC  
10A/6A 28VDCGeneral use,NO/NC  
1/3HP 250VAC,NO&NC  
10A 250VAC  
(Form A &  
Contact code 2 or blank:  
10A 250VAC(Form A)  
7A 250VAC(Form A)  
Form C NO)  
Contactcode 3:  
10A 250VAC(Form C,NO)  
7A 250VAC(Form C,NO)  
6A 250VAC(Form C,NC)  
FLA 5A, LRA 10A, 120/ 240VAC, NO  
Pilot Duty 240VA 240VAC  
TV-3 120VAC NO  
TV-5 120VAC NO  
Contact code 3:  
10A 250VAC(Form A)  
7A 250VAC(Form A)  
contact code 2(Form A or Form B)or Nil Form C):  
12A/ 15A 125VAC Resistive& Generaluse ,NO  
10A 250VAC/28VDCResistive& Generaluse ,NO  
1/3HP 250VAC,NO  
FLA 5A, LRA 10A, 120/ 240VAC, NO  
TV-3 120VAC NO  
contact code 1or 3:  
12A/ 15A 125VAC Resistive& Generaluse ,NO  
10A 250VAC/28VDCResistive& Generaluse ,NO  
1/3HP 250VAC,NO  
FLA 5A, LRA 10A, 120/ 240VAC, NO  
TV-3 120VAC NO  
contactcode 4:  
7A 250VACResistive& Generaluse ,NO&NC  
10A 250VACResistive& Generaluse ,NO  
contactcode 5:  
7A 250VACResistive& Generaluse ,NO&NC  
10A 250VACResistive& Generaluse ,NO  
contactcode 6:(Form A or Form C)  
10A 277VAC,Resistive&General use ,NO  
10A 277VAC,Resistive&General use ,NC  
(1) The above-mentioned unspecified temperature ratings, means that the ambient temperature is room temperature.  
(2) Only some typical ratings are listed above. Each rating’s test condition is different, so the electrical endurance will be different.  
If more details are required, please contact us.  
(3) For sealed type testing, please open the ventilation hole of case before test.  
2/4  
SRDI  
Ordering Information  
Nomenclature  
SRDI - S - 1 12  
D
M
1
-F -XX  
Special ParameterNil-Standard type  
6-6000V impulse withstandard voltage  
Insulation System:Nil-Standard, B-Class B, F-Class F  
Contact Material  
Moveable contact for FormC  
Nil-AgSnO φ2.8  
1-AgCdOφ2.8  
2-AgSnO φ3.0  
Moveable contact for FormA  
Nil-AgSnO φ3.0  
Moveable contact for FormB  
2
2
Nil-AgSnO  
2φ3.0  
1-AgCdOφ3.0  
6- AgNi φ3.0  
1-AgCdOφ3.0  
2
3-AgCdOφ3.0  
4-3 compounds φ3.0  
5-Cu plated with La φ3.0  
6-AgNi φ3.0  
Contact Form:Nil-Form C, B-Form B, M-Form A  
Coil PowerD-0.36W  
Coil Voltage (VDC):03, 05, 06, 09, 12, 15, 18, 24, 48, 60  
Number of Poles:1-1 Pole  
Protective Construction:S-Flux proofed,SH-Sealed type washable  
TypeDesignationSRDI  
Notes:(1)Dust covers with the marking of "VDE" are just for intend products with the suffixs of "D","D2", "D3","D6","DM"and"DM6".  
(2)All stationary contacts specified as: φ3.0mm.  
Outline Dimensions, Wiring Diagram, P.C. Board Layout (unit:mm)  
Unless otherwise specified:  
If dimension <1mm, tolerance: 0.2 mm;  
If dimension 1~5mm, tolerance: 0.3 mm;  
If dimension >5mm, tolerance: 0.4 mm.  
Note:Extended terminal dimension is dimension  
before soldering.  
Tolerance of P.C.B. layout: 0.1 mm.  
3/4  
SRDI  
Wiring Diagram (bottom view)  
Tolerance of P.C.B. layout: 0.1 mm.  
P.C.B. Layout (bottom view)  
Typical Applications  
Home appliances such as air conditioner, heater, etc.  
Automat  
Office equipment such as computer, fax machine, etc.  
Automatic eletric controlled window, automotive antenna, door lock, etc.  
Characteristic Curves  
Max. Switching Power  
Endurance Curve  
Coil Temp. Rise  
100  
10  
1
60  
50  
40  
30  
20  
10  
28VDC,250VACꢀꢁ  
100  
50  
AC(1a)  
AC(1c)  
1a  
1c  
10A  
10  
5
7A  
0A  
DC  
0
5
10  
15  
0
10  
100  
1000  
0
80  
90 100 110 120 130  
Contact Voltage(V)  
Contact Current(A)  
Percentage of Nominal Coil Voltage  
Disclaimer:  
This datasheet is the customers' reference. All the specification are subject to change without notice.  
We could not evaluate all the performance and all the parameters for every possible application.Thus the user should  
in a right position to choose the suitable product for their own application.For sealed relays after installation and cleaning,  
please open the vent hole on the case before use.If there is any query,please contact Sanyou for the technica service.  
However it is the user's responsibility to determine which product should be used only.  
Sanyou Corporation Limited, All rights of Sanyou to reserved.  
4/4  

相关型号:

SRDI-SH-124D3-B

Miniature Power Relay

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
SANYOU

SRDI-SH-124D3-F

Miniature Power Relay

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
SANYOU

SRDI-SH-124D4-B

Miniature Power Relay

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
SANYOU

SRDI-SH-124D4-F

Miniature Power Relay

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
SANYOU

SRDI-SH-124D5-B

Miniature Power Relay

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
SANYOU

SRDI-SH-124D5-F

Miniature Power Relay

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
SANYOU

SRDI-SH-124D6-B

Miniature Power Relay

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
SANYOU

SRDI-SH-124D6-F

Miniature Power Relay

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
SANYOU

SRDI-SH-124DB1-B

Miniature Power Relay

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
SANYOU

SRDI-SH-124DB1-F

Miniature Power Relay

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
SANYOU

SRDI-SH-124DM1-B

Miniature Power Relay

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
SANYOU

SRDI-SH-124DM1-F

Miniature Power Relay

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
SANYOU