SRDI-SH-160DM6-F-L-6 [SANYOU]

Miniature Power Relay;
SRDI-SH-160DM6-F-L-6
型号: SRDI-SH-160DM6-F-L-6
厂家: Sanyou Relays    Sanyou Relays
描述:

Miniature Power Relay

文件: 总3页 (文件大小:69K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
version:V2.3  
Miniature  
Power Relay  
SANYOU RELAYS  
SRD(I)-L-Series  
Relays for advanced technology  
Features  
●High contact capability: 12A switching capability.  
●Low coil power consumption, low price.  
●Microminiature relay, standard PCB terminal.  
●Compliance with RoHs and requirement for White Goods.  
Compliance  
with IEC60335-1 GWIF 850℃/GWIT 775℃  
and CTI>=250V。  
Impulse withstand voltage≥6000V product is available.  
Satisfy IEC60079-15 product is available  
.
Safety Approval  
UL,C-UL File No.:E190598  
VDE File No.: 40034479  
CQC File No.:CQC02001002126  
Contact Capacity  
Model  
SRD(I) -D-L  
SRD(I) -DM-L  
12A 277VAC  
Nominal switching  
capacity (res. load)  
NO12A 277VAC  
NO/NC7A 277VAC  
20A  
Max. switching current  
Max. switching voltage  
Max. switching power  
20A  
277VAC  
5,540VA  
277VAC  
5,540VA  
Characteristic Data  
Contact material  
silver alloy  
Initial contact resistance (at 6VDC 1A)  
100mΩ Max. (1A 6VDC)  
8msec. Max. (no diode)  
5msec. Max. (no diode)  
100MΩ Min.(DC500V)  
Operate time (at nominal volt.)  
Release time (at nominal volt.)  
Initial insulation resistance  
Between open contacts: AC 750V,50/60Hz 1min.  
Between coil and contact: standard product AC 1,500V,50/60Hz 1min  
SRD  
Between coil and contact: standard product AC 2,500V,50/60Hz 1min  
product with suffix"-6" : AC3000V,50/60Hz 1min  
Initial dielectric strength  
SRDI  
Between coil and contact: standard product ≥4800V 1.2/50us  
product with suffix"-6" ≥6000V 1.2/50us  
Impulse withstand voltage  
SRDI  
10~55Hz at double amplitude of 1.5 mm  
10~55Hz ouble mplitude 1.5 mm  
Function  
Destructive  
Function  
Vibration resistance  
Shock resistance  
at  
d
a
od  
10G Min.  
100G Min.  
10,000,000  
Destructive  
Mechanical(at 10,800ops./H)  
Endurance  
(operations)  
Electrical(at 360ops./H)  
50,000 (at 105℃)  
Ambient temperature  
Unit weight  
-40℃~+105℃(no condensation)  
Approx.8.5g  
1/3  
SRD(I)-L  
(at 20℃)  
Coil Data  
Nominal  
operating  
current  
Drop-out  
voltage  
(Min.)  
Max.  
allowable  
voltage  
Pick-up  
voltage  
(Max.)  
Nominal  
voltage  
(VDC)  
Nominal  
operating  
power  
Coil  
resistance  
10% ( Ω)  
10% ( mA)  
25  
70  
3
5
120.00  
71.42  
60.00  
40.00  
30.00  
24.00  
20.00  
15.00  
7.50  
6
100  
9
225  
130 % of  
nominal  
voltage  
75 % of  
nominal  
voltage  
5 % of  
nominal  
voltage  
12  
15  
18  
24  
48  
60  
400  
0.36W  
625  
900  
1,600  
6,400  
10,000  
6.00  
Safety Approval Ratings  
CQC  
UL/CUL  
E190598  
Approval  
VDE  
CQC02001002126  
40034479  
File No.  
12A 250/277VAC NO  
12A 125/250/277VAC,Resistive&General use ,NO  
17A 125/250/277VAC,Resistive&General use ,NO  
12A 125/250/277VAC NO  
17A 125/250/277VAC NO  
20A 125VAC NO  
Approved  
17A 125/250/277VAC NO  
ratings  
20A 125VAC,Resistive&General use ,NO  
Tv8  
(1) The above-mentioned unspecified temperature ratings, means that the ambient temperature is room temperature.  
(2) Only some typical ratings are listed above. Each rating’s test condition is different, so the electrical endurance will be different.  
If more details are required, please contact us.  
(3) For sealed type testing, please open the ventilation hole of case before test.  
Ordering Information  
Nomenclature  
- 6  
M 2 -F - L  
SRDI -S - 1 12  
D
withstand voltage:Nil-standard product  
6-6000V impulse withstandard voltage  
L-low temperature rised type  
Insulation System:Nil-Standard, B-Class B, F-Class F  
Contact Material:  
Moveable contact  
2-AgSnO φ3.5  
6- AgNi φ3.5  
stationary contact  
-AgSnO φ3.5  
6- AgNi φ3.5  
2
2
2
Contact Form:Nil-Form C, M-Form A  
Coil Power:D-0.36W  
Coil Voltage (VDC):03, 05, 06, 09, 12, 15, 18, 24, 48, 60  
Number of Poles:1-1 Pole  
Protective Construction:S-Flux proofed,SH-Sealed type washable  
TypeDesignation:SRD / SRDI  
Notes:(1)All stationary NC contacts specified as :φ3.0mm  
2/3  
SRD(I)-L  
Outline Dimensions, Wiring Diagram, P.C. Board Layout (unit:mm)  
Unless otherwise specified:  
If dimension <1mm, tolerance: 0.2 mm;  
If dimension 1~5mm, tolerance: 0.3 mm;  
If dimension >5mm, tolerance: 0.4 mm.  
Note:Extended terminal dimension is dimension  
before soldering.  
Tolerance of P.C.B. layout: 0.1 mm.  
Wiring Diagram (bottom view)  
Tolerance of P.C.B. layout: 0.1 mm.  
P.C.B. Layout (bottom view)  
Typical Applications  
Home appliances such as air conditioner, heater, etc.  
Automat Office equipment such as computer, fax machine, etc.  
Automatic eletric controlled window, automotive antenna, door lock, etc.  
Characteristic Curves  
Max. Switching Power  
Endurance Curve  
Coil Temp. Rise  
100  
60  
50  
40  
30  
20  
10  
100  
50  
AC  
12A  
10  
10  
5
DC  
1
0.5  
0
5
10  
15  
1030  
Contact Voltage(V)  
0
100  
1000  
0
80  
90 100 110 120 130  
Contact Current(A)  
Percentage of Nominal Coil Voltage  
Disclaimer:  
This datasheet is the customers' reference. All the specification are subject to change without notice.  
We could not evaluate all the performance and all the parameters for every possible application.Thus the user should  
in a right position to choose the suitable product for their own application.For sealed relays after installation and cleaning,  
please open the vent hole on the case before use.If there is any query,please contact Sanyou for the technica service.  
However it is the user's responsibility to determine which product should be used only.  
Sanyou Corporation Limited, All rights of Sanyou to reserved  
3/3  

相关型号:

SRDK-D

Miniature Power Magnetic Latching Relay

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 211
-
SANYOU

SRDK-DM

Miniature Power Magnetic Latching Relay

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 211
-
SANYOU

SRDK-S-105DM1-1R

Miniature Power Magnetic Latching Relay

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 211
-
SANYOU

SRDK-S-105DM1-2R

Miniature Power Magnetic Latching Relay

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 211
-
SANYOU

SRDK-S-106DM1-1R

Miniature Power Magnetic Latching Relay

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 211
-
SANYOU

SRDK-S-106DM1-2R

Miniature Power Magnetic Latching Relay

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 211
-
SANYOU

SRDK-S-109DM1-1R

Miniature Power Magnetic Latching Relay

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 211
-
SANYOU

SRDK-S-109DM1-2R

Miniature Power Magnetic Latching Relay

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 211
-
SANYOU

SRDK-S-112DM1-1R

Miniature Power Magnetic Latching Relay

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 211
-
SANYOU

SRDK-S-112DM1-2R

Miniature Power Magnetic Latching Relay

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 211
-
SANYOU