Miniature  
Power Relay  
SANYOU RELAYS  
SRG-Series  
Relays for advanced technology  
Features  
● High Contact Switching Capability:17 A  
● Lower coil power and Price  
● Microminiaturize ; Standard PCB terminal  
● Compliance with RoHS and the requirements for White Goods  
Satisfy IEC60335-1 product is available.  
● Ambient temperature range -40℃~105℃  
● Load switching 17A/277VAC; TV-8/125VAC,Max. 20A/277VAC  
● Provided with NO、NC and CO Contact form  
● Low coil power 0.36W, Class F insulation system  
● Withstanding 6KV impulse voltage. Dielectric strength 2.5KV r.m.s  
● Sealed and flux proof available  
Safety Approval  
UL,C-UL File No.: E190598  
VDE File No.40037165  
CQC File No.:CQC13002089151  
Contact Capacity  
Model  
SRG  
Nominal switching capacity (res. load)  
Max. switching current  
Max. switching voltage  
Max. switching power  
Characteristic Data  
Contact material  
Silver alloy  
Initial contact resistance  
Operate time (at nominal volt.)  
100mΩ Max. (1A 6VDC)  
15msec. Max. (no diode)  
10msec. Max. (no diode)  
100MΩ Min. (DC500V)  
Between open contacts:  
Between coil and contact:  
Destructive  
Release time (at nominal volt.)  
Initial insulation resistance  
m
Initial dielectric strength  
m
10~55Hz at double amplitude of 1.5 mm  
Vibration resistance  
Shock resistance  
Functional  
10~55Hz at double amplitude of 1.5 mm  
Destructive  
Functional  
(at 10,800 ops./h)  
(at 360 ops./h)  
10,000,000 cycles (at room temperature)  
100,000 cycles (at room temperature)  
Mechanical  
Electrical  
Endurance  
(operations)  
Ambient temperature  
Unit weight  
-40℃~+105℃ (no condensation)  
Approx. 15 g  
Coil Data (at 20℃)  
5
6
9
75 % of  
nominal  
voltage  
10 % of  
nominal  
voltage  
130 % of  
Approx.  
12  
nominal  
voltage  
900  
18  
24  
36  
48  
20.00  
0.36W  
1/3  
SRG  
Safety Approval Ratings  
Approval  
VDE  
File No.  
CQC13002089151  
40037165  
E190598  
10A 277VAC,Resistive&General Use,NO  
17A 277VAC,Resistive&General Use,NO  
20A 125VAC,Resistive&General Use,NO  
10A 277VAC,Resistive&General Use,NC  
TV-8 125VAC,NO  
10A 250VAC,NO  
Approved  
ratings  
17A/10A 277VAC,  
NO/NC (CO)  
17A 250VAC,NO  
17A/10A 250VAC, NO/NC CO  
1HP 250VAC/125VAC, NO  
(1) The above-mentioned unspecified temperature ratings, means that the ambient temperature is room temperature.  
(2) Only some typical ratings are listed above. Each rating’s test condition is different, so the electrical endurance will be different.  
If more details are required, please contact us.  
(3) For sealed type testing, please open the ventilation hole of case before test.  
Ordering Information  
Nomenclature  
Special Parameter:Nil-Standard type  
Letter or number-Special Requirment  
Insulation System:Nil-Class B, F-Class F  
Contact Material:Nil-AgSnO2,1-AgNi  
Contact Form:Nil-Form C ,B-Form B,M-Form A  
Coil Power: D-0.36W  
Coil Voltage (VDC):05, 06, 09, 12, 18,24, 36, 48  
Number of Poles:1-1 Pole  
Protective Construction:S-Flux proofed,SH-Sealed type washable  
Type Designation:SRG  
Outline Dimensions, Wiring Diagram, P.C. Board Layout (unit:mm)  
Unless otherwise specified:  
If dimension <1mm, tolerance: 0 .2mm;  
If dimension 1~5mm, tolerance: 0 .3mm;  
If dimension >5mm, tolerance: 0 .4mm.  
Note: 1. Extended terminal dimension is  
dimension before soldering.  
2. Tolerance of P.C.B. layout: 0 .1mm.  
(bottom view)  
2/3  
SRG  
Wiring Diagram (bottom view)  
P.C.B. Layout (bottom view)  
Typical Applications  
l
l
l
l
Home appliances such as air conditonner,electrical heater,etc.  
Automat  
Office equipment such as computer ,fax machine,etc.  
Automatic power window ,car antenna,door lock,etc.  
Characteristic Curves  
Coil Temp. Rise  
Max. Switching Power  
Endurance Curve  
3
17  
20  
Contact Voltage(V)  
Contact Current(A)  
Percentage of Nominal Coil Voltage  
Disclaimer:  
This datasheet is the customers' reference. All the specification are subject to change without notice.  
We could not evaluate all the performance and all the parameters for every possible application.Thus the user should  
in a right position to choose the suitable product for their own application.For sealed relays after installation and cleaning,  
please open the vent hole on the case before use.If there is any query,please contact Sanyou for the technica service.  
However it is the user's responsibility to determine which product should be used only.  
Sanyou Corporation Limited ,All rights of Sanyou to reserved  
3/3  

相关型号:

SRG-S-148DB1-F

Miniature Power Relay

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
SANYOU

SRG-S-148DM1-F

Miniature Power Relay

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
SANYOU

SRG-SH-105DB1-F

Miniature Power Relay

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
SANYOU

SRG-SH-105DM1-F

Miniature Power Relay

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
SANYOU

SRG-SH-106DB1-F

Miniature Power Relay

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
SANYOU

SRG-SH-106DM1-F

Miniature Power Relay

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
SANYOU

SRG-SH-109DB1-F

Miniature Power Relay

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
SANYOU

SRG-SH-109DM1-F

Miniature Power Relay

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
SANYOU

SRG-SH-112DB1-F

Miniature Power Relay

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
SANYOU

SRG-SH-112DM1-F

Miniature Power Relay

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
SANYOU

SRG-SH-118DB1-F

Miniature Power Relay

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
SANYOU

SRG-SH-118DM1-F

Miniature Power Relay

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
SANYOU