ATV31CU75N4T [SCHNEIDER]
enclosed variable speed drive ATV31 - 7.5 kW - 380..500 V - 3-phase supply;型号: | ATV31CU75N4T |
厂家: | SCHNEIDER ELECTRIC |
描述: | enclosed variable speed drive ATV31 - 7.5 kW - 380..500 V - 3-phase supply 电视 |
文件: | 总3页 (文件大小:111K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Product data sheet
ATV31CD11N4T
Characteristics
enclosed variable speed drive ATV31 - 11 kW -
380..500 V - 3-phase supply
Main
Range of product
Altivar 31
Product or component type
Product destination
Product specific application
Variable speed drive
Asynchronous motors
Wire guiding
Simple machine
Assembly style
Enclosed
Component name
EMC filter
ATV31
Integrated
Power supply voltage
Power supply frequency
Network number of phases
Motor power kW
Motor power hp
380...500 V - 15...10 %
50...60 Hz - 5...5 %
3 phases
11 kW
15 hp
Line current
28.4 A 500 V 1 kA
37.2 A 380 V 1 kA
Apparent power
25 kVA
Maximum prospective line Isc
Nominal output current
Maximum transient current
Power dissipation in W
Speed range
22 kA
27.7 A 4 kHz
41.6 A for 60 s
397 W at nominal load
1…50
Transient overtorque
150…170 % of nominal motor torque
Asynchronous motor control profile
Sensorless flux vector control with PWM type motor control signal
Factory set : constant torque
Analogue input number
IP degree of protection
3
IP55
Complementary
Power supply voltage limit
Power supply frequency limits
Speed drive output frequency
323…550 V
47.5…63 Hz
0.5…500 Hz
May 18, 2021
1
Nominal switching frequency
Switching frequency
Braking torque
4 kHz
2...16 kHz adjustable
<= 150 % during 60 s with braking resistor
100 % with braking resistor continuously
30 % without braking resistor
Regulation loop
Frequency PI regulator
Motor slip compensation
Suppressable
Automatic whatever the load
Adjustable
Output voltage
<= power supply voltage
Electrical connection
Al1, Al2, Al3, AOV, AOC, R1A, R1B, R1C, R2A, R2B, LI1...LI6 terminal 2.5 mm² AWG 14
L1, L2, L3, U, V, W, PA, PB, PA/+, PC/- terminal 2.5 mm² AWG 14
Tightening torque
Al1, Al2, Al3, AOV, AOC, R1A, R1B, R1C, R2A, R2B, LI1...LI6: 0.6 N.m
L1, L2, L3, U, V, W, PA, PB, PA/+, PC/-: 0.8 N.m
Insulation
Supply
Electrical between power and control
Internal supply for logic inputs 19…30 V, <100 mA overload protection
Internal supply for logic inputs 19…30 V, <100 mA short-circuit protection
Internal supply for reference potentiometer 10…10.8 V, <10 mA overload protection
Internal supply for reference potentiometer 10…10.8 V, <10 mA short-circuit protection
Analogue input type
AI3 configurable current 0...20 mA, impedance: 250 Ohm
AI1 configurable voltage 0...10 V, input voltage 30 V max, impedance: 30000 Ohm
AI2 configurable voltage +/- 10 V, input voltage 30 V max, impedance: 30000 Ohm
Input sampling time
LI1...LI6: 4 ms discrete
AI1, AI2, AI3: 8 ms analog
Output response time
AOV, AOC 8 ms for analog
R1A, R1B, R1C, R2A, R2B 8 ms for discrete
Linearity error
+/- 0.2 % for output
2
Analogue output number
Analogue output type
AOC configurable current: 0...20 mA, impedance: 800 Ohm, resolution: 8 bits
AOV configurable voltage: 0...10 V, impedance: 470 Ohm, resolution: 8 bits
Discrete input logic
Positive logic (source) (LI1...LI6), < 5 V (state 0), > 11 V (state 1)
Logic input not wired (LI1...LI4), < 13 V (state 1)
Negative logic (source) (LI1...LI6), > 19 V (state 0)
Discrete output number
Discrete output type
2
Configurable relay logic: (R1A, R1B, R1C) 1 NO + 1 NC - 100000 cycles
Configurable relay logic: (R2A, R2B) NC - 100000 cycles
Minimum switching current
Maximum switching current
10 mA 5 V DC R1-R2
2 A at 250 V AC on inductive load - cos phi = 0.4 - L/R = 7 ms (R1-R2)
2 A at 30 V DC on inductive load - cos phi = 0.4 - L/R = 7 ms (R1-R2)
5 A at 250 V AC on resistive load - cos phi = 1 - L/R = 0 ms (R1-R2)
5 A at 30 V DC on resistive load - cos phi = 1 - L/R = 0 ms (R1-R2)
Discrete input number
6
Discrete input type
(LI1...LI6) programmable at 24 V, 0…100 mA for PLC, impedance: 3500 Ohm
Acceleration and deceleration ramps
Linear adjustable separately from 0.1 to 999.9 s
S, U or customized
Braking to standstill
Protection type
By DC injection
Input phase breaks: drive
Line supply overvoltage and undervoltage safety circuits: drive
Line supply phase loss safety function, for three phases supply: drive
Motor phase breaks: drive
Overcurrent between output phases and earth (on power up only): drive
Overheating protection: drive
Short-circuit between motor phases: drive
Thermal protection: motor
Insulation resistance
Local signalling
>= 500 mOhm 500 V DC for 1 minute
1 LED (red) for drive voltage
Four 7-segment display units for CANopen bus status
Time constant
5 ms for reference change
Frequency resolution
Display unit: 0.1 Hz
Analog input: 0.1...100 Hz
Communication port protocol
2
CANopen
Modbus
Connector type
1 RJ45 for CANopen via VW3 CANTAP2 adaptor
1 RJ45 for Modbus
Physical interface
Transmission frame
Transmission rate
RS485 multidrop serial link for Modbus
RTU for Modbus
10, 20, 50, 125, 250, 500 kbps or 1 Mbps for CANopen via VW3 CANTAP2 adaptor
4800, 9600 or 19200 bps for Modbus
Number of addresses
Number of drive
1…127 for CANopen via VW3 CANTAP2 adaptor
1…247 for Modbus
127 for CANopen via VW3 CANTAP2 adaptor
31 for Modbus
Marking
CE
Operating position
Net weight
Vertical +/- 10 degree
32.5 kg
Environment
Dielectric strength
2410 V DC between earth and power terminals
3400 V AC between control and power terminals
Electromagnetic compatibility
1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
Standards
EN 50178
C-Tick
2
Product certifications
Pollution degree
Protective treatment
Vibration resistance
TC
1 gn (f= 13…150 Hz) conforming to EN/IEC 60068-2-6
1.5 mm (f= 3…13 Hz) conforming to EN/IEC 60068-2-6
Shock resistance
Relative humidity
15 gn for 11 ms conforming to EN/IEC 60068-2-27
5…95 % without condensation conforming to IEC 60068-2-3
5…95 % without dripping water conforming to IEC 60068-2-3
Ambient air temperature for storage
Ambient air temperature for operation
-25…70 °C
-10…50 °C without derating (with protective cover on top of the drive)
-10…60 °C with derating factor (without protective cover on top of the drive)
Operating altitude
<= 1000 m without derating
>= 1000 m with current derating 1 % per 100 m
Contractual warranty
Warranty
18 months