CAD326F7 [SCHNEIDER]
Special Relay,;型号: | CAD326F7 |
厂家: | SCHNEIDER ELECTRIC |
描述: | Special Relay, |
文件: | 总2页 (文件大小:134K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Product datasheet
CAD326F7
Characteristics
TeSys D control relay - 3 NO + 2 NC - <= 690 V -
110 V AC standard coil
Main
Range
TeSys
Product name
TeSys CAD
Control relay
CAD
Product or component type
Device short name
Contactor application
Control circuit
Complementary
Utilisation category
AC-15
AC-14
DC-13
Pole contact composition
[Ue] rated operational voltage
Control circuit type
3 NO + 2 NC
<= 690 V AC 25...400 Hz
AC at 50/60 Hz
[Uc] control circuit voltage
[Uimp] rated impulse withstand voltage
110 V AC 50/60 Hz
6 kV conforming to IEC 60947
10 A (at 60 °C)
[Ith] conventional free air thermal
current
Irms rated making capacity
140 A AC conforming to IEC 60947-5-1
250 A DC conforming to IEC 60947-5-1
[Icw] rated short-time withstand current
100 A - 1 s
120 A - 500 ms
140 A - 100 ms
Associated fuse rating
10 A gG conforming to IEC 60947-5-1
[Ui] rated insulation voltage
600 V UL certified
600 V CSA certified
690 V conforming to IEC 60947-5-1
Mounting support
Rail
Plate
Connections - terminals
Lugs-ring terminals (external diameter: 8 mm)
Operational: 0.8...1.1 Uc at 50 Hz
Control circuit voltage limits
Aug 16, 2019
1
Operational: 0.85...1.1 Uc at 60 Hz
Drop-out: 0.3...0.6 Uc
Operating time
12...22 ms coil energisation and NO closing
4...12 ms coil de-energisation and NO opening
4...19 ms coil energisation and NC opening
6...17 ms coil de-energisation and NC closing
Mechanical durability
30 Mcycles
Maximum operating rate
Inrush power in VA
180 cyc/mn
70 VA 50 Hz (at 20 °C)
8 VA 50 Hz (at 20 °C)
17 V
Hold-in power consumption in VA
Minimum switching voltage
Minimum switching current
Non-overlap time
5 mA
1.5 ms on energisation between NC and NO contact
1.5 ms on de-energisation between NC and NO contact
Insulation resistance
> 10 MOhm
Mechanical robustness
Shocks control relay open: 10 Gn for 11 ms conforming to IEC 60068-2-27
Shocks control relay closed: 15 Gn for 11 ms conforming to IEC 60068-2-27
Vibrations control relay open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Vibrations control relay closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6
Height
77 mm
45 mm
84 mm
0.58 kg
Width
Depth
Net weight
Environment
Standards
BS 4794
EN 60947-5
IEC 60947-5-1
NF C 63-140
VDE 0660
Product certifications
UL
CSA
IP degree of protection
IP2x front face conforming to VDE 0106
TH conforming to IEC 60068
-40…70 °C
Protective treatment
Ambient air temperature for operation
Ambient air temperature for storage
Operating altitude
-60…80 °C
3000 m without
Offer Sustainability
Sustainable offer status
REACh Regulation
Green Premium product
REACh Declaration
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
EU RoHS Declaration
Toxic heavy metal free
Mercury free
Yes
Yes
RoHS exemption information
China RoHS Regulation
Environmental Disclosure
Circularity Profile
Yes
Download RoHS China Declaration
Product Environmental Profile
End of Life Information
WEEE
The product must be disposed on European Union markets following specific waste collection and
never end up in rubbish bins
Contractual warranty
Warranty
18 months
2
相关型号: