Product data sheet
Characteristics
CAD50P7
TeSys D control relay - 5 NO - <= 690 V - 230
V AC standard coil
Main
Range
TeSys
Product name
TeSys CAD
Control relay
Product or component
type
Device short name
Contactor application
Utilisation category
CAD
Control circuit
AC-14
AC-15
DC-13
Pole contact composi-
tion
5 NO
[Ue] rated operational
voltage
<= 690 V AC 25...400 Hz
Control circuit type
AC 50/60 Hz
Control circuit voltage
230 V AC 50/60 Hz
Complementary
[Uimp] rated impulse withstand voltage
[Ith] conventional free air thermal current
Irms rated making capacity
6 kV conforming to IEC 60947
10 A at <= 60 °C
250 A DC conforming to IEC 60947-5-1
140 A AC conforming to IEC 60947-5-1
[Icw] rated short-time withstand current
140 A 100 ms
120 A 500 ms
100 A 1 s
Associated fuse rating
10 A gG conforming to IEC 60947-5-1
[Ui] rated insulation voltage
690 V conforming to IEC 60947-5-1
600 V certifications CSA
600 V certifications UL
Mounting support
Plate
Rail
Connections - terminals
Screw clamp terminals 2 cable(s) 1...4 mm² - cable stiffness: solid - without cable
end
Screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: solid - without cable
end
Screw clamp terminals 2 cable(s) 1...2.5 mm² - cable stiffness: flexible - with ca-
ble end
Screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: flexible - with cable
end
Screw clamp terminals 2 cable(s) 1...4 mm² - cable stiffness: flexible - without ca-
ble end
Screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: flexible - without ca-
ble end
Tightening torque
1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2
Control circuit voltage limits
0.3...0.6 Uc drop-out
0.85...1.1 Uc operational 60 Hz
0.8...1.1 Uc operational 50 Hz
Operating time
4...12 ms coil de-energisation and NO opening
12...22 ms coil energisation and NO closing
Mechanical durability
Operating rate
30 Mcycles
180 cyc/mn
Inrush power in VA
70 VA at 20 °C 50 Hz
8 VA at 20 °C 50 Hz
Hold-in power consumption in VA
May 11, 2016
1
Minimum switching voltage
Minimum switching current
Non-overlap time
17 V
5 mA
1.5 ms on de-energisation (between NC and NO contact)
1.5 ms on energisation (between NC and NO contact)
Insulation resistance
Height
> 10 MOhm
77 mm
Width
45 mm
Depth
84 mm
Product weight
0.58 kg
Environment
Standards
BS 4794
EN 60947-5
IEC 60947-5-1
NF C 63-140
VDE 0660
Product certifications
CSA
UL
IP degree of protection
IP2x front face conforming to VDE 0106
TH conforming to IEC 60068
-40...70 °C
Protective treatment
Ambient air temperature for operation
Ambient air temperature for storage
Operating altitude
-60...80 °C
3000 m without derating in temperature
Mechanical robustness
Vibrations control relay closed 4 Gn, 5...300 Hz IEC 60068-2-6
Vibrations control relay open 2 Gn, 5...300 Hz IEC 60068-2-6
Shocks control relay closed 15 Gn for 11 ms IEC 60068-2-27
Shocks control relay open 10 Gn for 11 ms IEC 60068-2-27
Offer Sustainability
Sustainable offer status
RoHS
Green Premium product
Compliant - since 0627 -
Schneider Electric declaration of conformity
REACh
Reference not containing SVHC above the threshold
Available
Product environmental profile
Product end of life instructions
Need no specific recycling operations
2