HGA260306 [SCHNEIDER]

Thermal Magnetic Circuit Breaker,;
HGA260306
型号: HGA260306
厂家: SCHNEIDER ELECTRIC    SCHNEIDER ELECTRIC
描述:

Thermal Magnetic Circuit Breaker,

电路保护
文件: 总2页 (文件大小:100K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Product data sheet  
HGA260306  
Characteristics  
PowerPact H I-Line Circuit  
Breaker,ThermMagn,30A,2P,600V,18kA  
Product availability : Non-Stock - Not normally stocked in distribution facility  
Price* : 1,338.00 USD  
Main  
Product or component type  
Range of product  
Trip Unit Type  
Circuit breaker  
PowerPact H  
Thermal-magnetic  
G
Breaking capacity code  
Complementary  
Line Rated Current  
Number of Poles  
Interrupt Rating  
30 A  
2P  
65 kA at 240 V AC  
35 kA at 480 V AC  
18 kA at 600 V AC  
20 kA at 500 V DC  
20 kA at 250 V DC  
System Voltage  
250 V DC  
500 V DC  
600 V AC  
Continuous current rating  
Mounting mode  
80 %  
I-Line  
Electrical connection  
I-Line connection line  
Lugs load  
Wire Gauge  
Phase  
AWG 14...AWG 3/0 (aluminium/copper)  
CB  
Magnetic hold current  
Magnetic tripping current  
Height  
350 A  
750 A  
9.73 in  
2.94 in  
4.8 in  
Width  
Depth  
May 3, 2019  
1
Environment  
Product certifications  
CE  
CSA  
IEC  
UL listed  
Ambient air temperature for operation  
104 °F (40 °C)  
Ordering and shipping details  
Category  
01117 - HG, HJ, JG, JJ I-LINE BREAKER/SWITCH  
Discount Schedule  
GTIN  
DE2  
00785901492351  
Nbr. of units in pkg.  
Package weight(Lbs)  
Returnability  
1
3
Y
Country of origin  
US  
Offer Sustainability  
Sustainable offer status  
RoHS (date code: YYWW)  
Green Premium product  
Compliant - since 0832 - Schneider Electric declaration of conformity  
Schneider Electric declaration of conformity  
REACh  
Reference not containing SVHC above the threshold  
Reference not containing SVHC above the threshold  
Product environmental profile  
Product end of life instructions  
California proposition 65  
- - - - - - - Substance 1  
Available  
Need no specific recycling operations  
WARNING: This product can expose you to chemicals including:  
DINP, which is known to the State of California to cause cancer, and  
DIDP, which is known to the State of California to cause Birth Defects or other reproductive harm.  
For more information go to www.p65warnings.ca.gov  
- - - - - - - Substance 2  
- - - - - - - More information  
Contractual warranty  
Warranty period  
18 months  
2

相关型号:

HGA260351

Circuit breaker, PowerPacT H, thermal magnetic, I-Line, 35A, 2 pole, 18 kA, 600 VAC, phase AB, 80% rated
SCHNEIDER

HGA260352

Circuit breaker, PowerPacT H, thermal magnetic, I-Line, 35A, 2 pole, 18 kA, 600 VAC, phase AC, 80% rated
SCHNEIDER

HGA260353

Circuit breaker, PowerPact H, I-Line, thermal magnetic, 35A, 2 pole,18 kA, 600 VAC
SCHNEIDER

HGA260403

Circuit breaker, PowerPact H, I-Line, thermal magnetic, 40A, 2 pole,18 kA, 600 VAC
SCHNEIDER

HGA260451

Circuit breaker, PowerPacT H, thermal magnetic, I-Line, 45A, 2 pole, 18 kA, 600 VAC, phase AB, 80% rated
SCHNEIDER

HGA260453

Circuit breaker, PowerPact H, I-Line, thermal magnetic, 45A, 2 pole,18 kA, 600 VAC
SCHNEIDER

HGA260454

Circuit breaker, PowerPact H, I-Line, thermal magnetic, 45A, 2 pole,18 kA, 600 VAC
SCHNEIDER

HGA260455

Circuit breaker, PowerPact H, I-Line, thermal magnetic, 45A, 2 pole,18 kA, 600 VAC
SCHNEIDER

HGA260456

Circuit breaker, PowerPact H, I-Line, thermal magnetic, 45A, 2 pole,18 kA, 600 VAC
SCHNEIDER

HGA260503

Circuit breaker, PowerPact H, I-Line, thermal magnetic, 50A, 2 pole,18 kA, 600 VAC
SCHNEIDER

HGA260605

Circuit breaker, PowerPact H, I-Line, thermal magnetic, 60A, 2 pole,18 kA, 600 VAC
SCHNEIDER

HGA260703

Circuit breaker, PowerPact H, I-Line, thermal magnetic, 70A, 2 pole,18 kA, 600 VAC
SCHNEIDER