Product data sheet
LC1K0601B7
Characteristics
TeSys K contactor - 3P - AC-3 <= 440 V 6 A - 1
NC aux. - 24 V AC coil
Product availability : Stock - Normally stocked in distribution facility
Price* : 57.00 USD
Main
Range
TeSys
Product or component type
Product name
Contactor
TeSys K
LC1K
Device short name
Device application
Contactor application
Control
Motor control
Complementary
Utilisation category
AC-4
AC-3
Poles description
3P
Power pole contact composition
[Ue] rated operational voltage
3 NO
Power circuit: 690 V AC 50/60 Hz
Signalling circuit: <= 690 V AC 50/60 Hz
[Ie] rated operational current
Control circuit type
6 A<= 440 V AC AC-3 power circuit
AC 50/60 Hz
[Uc] control circuit voltage
Motor power kW
24 V AC 50/60 Hz
1.5 kW 220...230 V AC 50/60 Hz AC-3
2.2 kW 380...415 V AC 50/60 Hz AC-3
3 kW 440 V AC 50/60 Hz AC-3
3 kW 480 V AC 50/60 Hz AC-3
3 kW 500...600 V AC 50/60 Hz AC-3
3 kW 660...690 V AC 50/60 Hz AC-3
1.5 kW 400 V AC 50/60 Hz AC-4
Auxiliary contact composition
[Uimp] rated impulse withstand voltage
Overvoltage category
1 NC
8 kV
III
* Price is “List Price” and may be subject to a trade discount – check with your local distributor or retailer for actual price.
Apr 27, 2021
1
[Ith] conventional free air thermal
current
20 A 122 °F (50 °C) power circuit
10 A 122 °F (50 °C) signalling circuit
Irms rated making capacity
110 A AC power circuit NF C 63-110
110 A AC power circuit IEC 60947
110 A AC signalling circuit IEC 60947
Rated breaking capacity
110 A 415 V IEC 60947
110 A 440 V IEC 60947
80 A 500 V IEC 60947
110 A 220...230 V IEC 60947
110 A 380...400 V IEC 60947
70 A 660...690 V IEC 60947
[Icw] rated short-time withstand current
90 A 122 °F (50 °C) - 1 s power circuit
85 A 122 °F (50 °C) - 5 s power circuit
80 A 122 °F (50 °C) - 10 s power circuit
60 A 122 °F (50 °C) - 30 s power circuit
45 A 122 °F (50 °C) - 1 min power circuit
40 A 122 °F (50 °C) - 3 min power circuit
20 A 122 °F (50 °C) - >= 15 min power circuit
80 A - 1 s signalling circuit
90 A - 500 ms signalling circuit
110 A - 100 ms signalling circuit
Associated fuse rating
25 A gG <= 440 V power circuit
25 A aM power circuit
10 A gG signalling circuit IEC 60947
10 A gG signalling circuit VDE 0660
Average impedance
3 mOhm - Ith 20 A 50 Hz power circuit
[Ui] rated insulation voltage
Power circuit 600 V UL 508
Power circuit 690 V IEC 60947-4-1
Signalling circuit 690 V IEC 60947-4-1
Signalling circuit 690 V IEC 60947-5-1
Signalling circuit 600 V UL 508
Power circuit 600 V CSA C22.2 No 14
Signalling circuit 600 V CSA C22.2 No 14
Insulation resistance
> 10 MOhm signalling circuit
30 VA 68 °F (20 °C))
4.5 VA 68 °F (20 °C))
1.3 W
Inrush power in VA
Hold-in power consumption in VA
Heat dissipation
Control circuit voltage limits
Operational: 0.8...1.15 Uc (at <50 °C)
Drop-out: 0.2...0.75 Uc (at <50 °C)
Connections - terminals
screw clamp terminals 1 0.00…0.01 in² (1.5…4 mm²)solid
screw clamp terminals 1 0.00…0.01 in² (0.75…4 mm²)flexible without cable end
screw clamp terminals 1 0.00…0.00 in² (0.34…2.5 mm²)flexible with cable end
screw clamp terminals 2 0.00…0.01 in² (1.5…4 mm²)solid
screw clamp terminals 2 0.00…0.01 in² (0.75…4 mm²)flexible without cable end
screw clamp terminals 2 0.00…0.00 in² (0.34…1.5 mm²)flexible with cable end
Maximum operating rate
Auxiliary contacts type
Signalling circuit frequency
Minimum switching current
Minimum switching voltage
Mounting support
3600 cyc/h
type instantaneous 1 NC
<= 400 Hz
5 mA signalling circuit
17 V signalling circuit
Plate
Rail
Tightening torque
Operating time
11.51 lbf.in (1.3 N.m) screw clamp terminals Philips No 2
11.51 lbf.in (1.3 N.m) screw clamp terminals flat Ø 6 mm
10...20 ms coil de-energisation and NO opening
10...20 ms coil energisation and NO closing
Safety reliability level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Non overlap distance
Mechanical durability
Electrical durability
0.02 in (0.5 mm)
10 Mcycles
1.3 Mcycles 6 A AC-3 <= 440 V
Mechanical robustness
Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27
2
Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6
Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Height
2.28 in (58 mm)
1.77 in (45 mm)
2.24 in (57 mm)
0.40 lb(US) (0.18 kg)
Width
Depth
Net weight
Environment
Standards
BS 5424
IEC 60947
NF C 63-110
VDE 0660
Product certifications
UL
CSA
IP degree of protection
Protective treatment
IP2x VDE 0106
TC conforming to IEC 60068
TC conforming to DIN 50016
Ambient air temperature for storage
Operating altitude
-58…176 °F (-50…80 °C)
2000 m without derating
Flame retardance
V1 conforming to UL 94
Requirement 2 conforming to NF F 16-101
Requirement 2 conforming to NF F 16-102
Ordering and shipping details
Category
22326 - CTR,K-LINE,AC,OPEN,NONREV
Discount Schedule
GTIN
I12
00785901368830
Nbr. of units in pkg.
Package weight(Lbs)
Returnability
1
1 lb(US) (0.45 kg)
No
ID
Country of origin
Packing Units
Unit Type of Package 1
PCE
Package 1 Height
1.89 in (4.8 cm)
2.44 in (6.2 cm)
2.60 in (6.6 cm)
S02
Package 1 width
Package 1 Length
Unit Type of Package 2
Number of Units in Package 2
Package 2 Weight
Package 2 Height
50
20.61 lb(US) (9.35 kg)
5.91 in (15 cm)
11.81 in (30 cm)
15.75 in (40 cm)
P06
Package 2 width
Package 2 Length
Unit Type of Package 3
Number of Units in Package 3
Package 3 Weight
Package 3 Height
400
183.73 lb(US) (83.34 kg)
17.72 in (45 cm)
31.50 in (80 cm)
23.62 in (60 cm)
Package 3 width
Package 3 Length
Offer Sustainability
Sustainable offer status
Green Premium product
3
California proposition 65
WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony
trioxide, which is known to the State of California to cause cancer. For more information go to
www.P65Warnings.ca.gov
REACh Regulation
REACh free of SVHC
EU RoHS Directive
REACh Declaration
Yes
Compliant
EU RoHS Declaration
Toxic heavy metal free
Mercury free
Yes
Yes
Yes
RoHS exemption information
China RoHS Regulation
China RoHS declaration
Pro-active China RoHS declaration (out of China RoHS legal scope)
Environmental Disclosure
Circularity Profile
WEEE
Product Environmental Profile
End of Life Information
The product must be disposed on European Union markets following specific waste collection and
never end up in rubbish bins.
Contractual warranty
Warranty
18 months
4
Product data sheet
LC1K0601B7
Dimensions Drawings
Dimensions
Contactors LC1 K, LP1 K, LP4 K: Mounting on Panel
Contactors LC1 K, LP1 K, LP4 K: Mounting on Rail AM1 DP200 or AM1 DE200 (35 mm)
5
Product data sheet
LC1K0601B7
Connections and Schema
Wiring
3-Pole Contactors: 3P + N/O
3-Pole Contactors: 3P + N/C
6
相关型号: