Thermal (T- and TA-Line)  
T12-211  
https://www.schurter.com /PG17_20  
Circuit Breaker for Equipment thermal, Threaded neck type, Reset type, Quick connect terminals  
See below:  
Approvals and Compliances  
Description  
Applications  
- Threaded neck type  
- Thermal circuit breaker  
- 1-pole  
- Power supplies  
- Uninterruptible power supply  
- Power tools  
- Reset type  
- Household appliances  
- Quick connect terminals 6.3 x 0.8 mm  
Weblinks  
pdf datasheet, html-datasheet, General Product Information, Distributor-  
Stock-Check, Detailed request for product, Product News  
Unique Selling Proposition  
- Compact design  
- Positively trip-free release  
- Available with cover  
- Different mounting possibilities  
Technical Data  
Rated Voltage AC  
240 V; 50/60 Hz  
Overload  
IEC: min. 40trips  
@ 6 x Ir, cos φ 0.6  
UL / CSA: min. 50trips  
@ 1.5 x Ir, cos φ 0.75  
-5°C to 60°C  
1.5 mm @ 10 - 60 Hz  
acc. to IEC 60068-2-6, test Fc  
10 G @ 60 - 500 Hz  
acc. to IEC 60068-2-6, test Fc  
100 G / 6ms  
acc. to IEC 60068-2-27, test Ea  
Thermal  
Reset type  
ca. 10g  
Rated Voltage DC  
Rated current range AC  
Conditional short circuit ca-  
pacity  
28 V  
0.05 - 15/16 A , see approbations  
IEC: Inc, PC1, AC 240 V: 1 kA  
Ambient temperature  
Vibration Resistance  
Short circuit capacity Icn  
at In < 7 A/240 VAC : 8 x In  
at In 7 A/240 VAC : 200 A  
AC/DC 28 V : 400 A  
from front side IP 40 acc. to IEC 60529  
50Hz: > 1.5kV  
Impulse 1.2/50 μs: > 2.5kV  
500VDC > 100 MΩ  
2 x Ir: 5000switching cycles  
Degree of Protection  
Dielectric Strength  
Shock Resistance  
Tripping Type  
Actuation Type  
Weight  
Insulation Resistance  
Endurance typical  
Endurance minimum  
Reset type  
AC : 2 x Ir , cos φ 0.6 :  
DC : 2 x Ir , L/R = 2 - 3 ms :  
50switching cycles  
Approvals and Compliances  
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about  
Approvals  
Approvals  
The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.  
Approval Reference Type: T12  
Approval Logo  
Certificates  
Certification Body  
Description  
VDE Approvals  
VDE  
VDE Certificate Number: 99673  
UL Approvals  
UL  
UL File Number: E71572  
CQC Approvals  
CQC  
CCC Certificate Number: 2012010307564275  
1
Circuit Breakers  
 
Thermal (T- and TA-Line)  
T12-211  
https://www.schurter.com /PG17_20  
Product standards  
Product standards that are referenced  
Organization  
Design  
Standard  
Description  
Designed according to  
IEC 60934  
Circuit-breakers for equipment (CBE)  
Designed according to  
Designed according to  
Designed according to  
UL 1077  
Standard for Supplementary Protectors for Use in Electrical Equipment  
Supplementary Protectors  
CSA C22.2 No. 235  
GB 17701  
Circuit-breaker for equipment  
Application standards  
Application standards where the product can be used  
Organization  
Design  
Standard  
Description  
Designed for applications acc.  
IEC/UL 60950  
IEC 60950-1 includes the basic requirements for the safety of information  
technologyequipment.  
Compliances  
The product complies with following Guide Lines  
Identification  
Details  
Initiator  
Description  
CE declaration of conformity  
SCHURTER AG  
The CE marking declares that the product complies with the applicable  
requirements laid down in the harmonisation of Community legislation on  
its affixing in accordance with EU Regulation 765/2008.  
RoHS  
SCHURTER AG  
SCHURTER AG  
SCHURTER AG  
EU Directive RoHS 2011/65/EU  
China RoHS  
REACH  
The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March  
2007. It is similar to the EU directive RoHS.  
On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration,  
Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as  
"REACH") entered into force.  
Dimension [mm]  
T12-211  
3/8-27UNS-2A  
Ø 5.7  
8.8  
1
2
24.6  
11.5  
31– 0.2  
SW  
14  
2
Circuit Breakers  
Thermal (T- and TA-Line)  
T12-211  
https://www.schurter.com /PG17_20  
T12-211SN  
6
4
5
3/8-27UNS-2A  
Ø 5.7  
8.8  
A 6.3  
1
2
3
2.5  
20.2  
24.6  
31– 0.2  
SW  
14  
16  
16  
8.9  
3
Circuit Breakers  
Thermal (T- and TA-Line)  
T12-211  
https://www.schurter.com /PG17_20  
Diagrams  
Tap 4,8 x 0,8 mm  
Tap 4,8 x 0,8 mm  
1
1
2
2
3
Tap 4,8 x 0,8 mm  
Tap 4,8 x 0,8 mm  
1
5 4  
1
5 4  
2
6
2 3 6  
Approval  
Main circuit  
Auxiliary circuit  
Rated current  
Rated current  
Rated voltage AC  
Rated voltage DC  
Rated voltage AC  
Rated voltage DC  
UL 1077  
CSA C22.2 No. 235  
0.05...15 A  
240 V  
28 V  
2 A  
3 A  
120 V  
-
-
28 V  
CSA C22.2 No. 235  
0.3...16 A  
240 V  
28 V  
1 A  
240 V  
-
IEC 60934  
GB 17701  
0.05...16 A  
0.05...16 A  
240 V  
240 V  
28 V  
28 V  
1 A  
1 A  
240 V  
240 V  
28 V  
28 V  
4
Circuit Breakers  
Thermal (T- and TA-Line)  
T12-211  
https://www.schurter.com /PG17_20  
Typical internal resistance  
Rated Current [A]  
Internal Resistance []  
0.05  
225.000  
3.300  
0.50  
1.00  
0.880  
2.00  
0.267  
3.00  
0.128  
4.00  
0.073  
5.00  
0.040  
6.00  
0.031  
7.00  
0.018  
8.00  
0.018  
9.00  
0.010  
10.00  
11.00  
12.00  
13.00  
14.00  
15.00  
16.00  
0.0087  
0.0087  
0.0087  
0.0087  
0.0070  
0.0070  
0.0055  
Effect of ambient temperature  
The units are calibrated for an ambient temperature of +23°C. To determine the rated cur-  
rent for a lower or higher ambient temperature, use a correction factor (typical value) from  
the table below:  
Ambient temperature [°C]  
Correction factor  
-5  
0
0.87  
0.90  
0.95  
1.00  
1.05  
1.12  
1.20  
1.30  
10  
23  
30  
40  
50  
60  
Example: Rated current = 5 A; Environmental temperature = 50 °C; --> Correction factor =  
1.2; Resulting current = 6.0 A  
5
Circuit Breakers  
Thermal (T- and TA-Line)  
T12-211  
https://www.schurter.com /PG17_20  
Time-Current-Curves  
[ min] [ sec]  
10'000  
< 7,0 A  
> 7,0 A  
60  
2´000  
30  
20  
1´000  
10  
500  
5
200  
100  
1
50  
20  
10  
5
2
1
0,5  
0,3  
0,2  
0,1  
1,05 1,32  
2
3
4
5
8
10  
Multiple of Rated Current In  
Reference Temperature +23°  
Config. Code  
T12|-|1|2|3|A|B|C|-|1.23|  
The characters are placeholders for the correspondingly keys of selections from the key tables.  
T12|-|1|2|3|A|B|C|-|1.23|= Mounting  
T12|-|1|2|3|A|B|C|-|1.23|= Setting indication  
Mounting  
Configuration  
key  
Setting indication  
Configuration  
key  
Threaded neck type with hexagonal- and knurled nut  
2
Setting indication  
R
T12|-|1|2|3|A|B|C|-|1.23|= Actuation Type  
T12|-|1|2|3|A|B|C|-|1.23|= Rated current  
Actuation Type  
Configuration  
key  
Rated current  
Configuration  
key  
Reset type  
1
0.05 A  
0.05  
0.1  
0.15  
0.2  
0.3  
0.4  
0.5  
0.6  
0.7  
0.8  
0.9  
1
0.1 A  
T12|-|1|2|3|A|B|C|-|1.23|= Terminal  
0.15 A  
Terminal  
Configuration  
key  
0.2 A  
0.3 A  
Quick connect terminal 6.3x0.8mm  
1
0.4 A  
0.5 A  
0.6 A  
T12|-|1|2|3|A|B|C|-|1.23|= Auxiliary contact  
0.7 A  
Auxiliary contact  
Configuration  
key  
0.8 A  
0.9 A  
Auxiliary contact  
S
1.0  
1.1 A  
1.1  
1.2  
1.3  
1.4  
T12|-|1|2|3|A|B|C|-|1.23|= Shunt terminal  
1.2 A  
1.3 A  
Shunt terminal  
Configuration  
key  
1.4 A  
Other rated currents on request  
Shunt terminal  
N
6
Circuit Breakers  
Thermal (T- and TA-Line)  
T12-211  
https://www.schurter.com /PG17_20  
Rated current  
Configuration  
key  
Rated current  
Configuration  
key  
1.5 A  
1.5  
1.6  
1.7  
1.8  
1.9  
2
5.5 A  
5.5  
6
1.6 A  
6.0  
1.7 A  
6.5 A  
6.5  
7
1.8 A  
7.0 A  
1.9 A  
7.5 A  
7.5  
8
2.0 A  
8.0 A  
2.1 A  
2.1  
2.3  
2.5  
2.8  
3
8.5 A  
8.5  
9
2.3 A  
9.0 A  
2.5 A  
9.5 A  
9.5  
10  
11  
12  
13  
14  
15  
16  
2.8 A  
10.0 A  
3.0 A  
11.0 A  
3.3 A  
3.3  
3.5  
4
12.0 A  
3.5 A  
13.0 A  
4.0 A  
14.0 A  
4.5 A  
4.5  
5
15.0 A  
5.0 A  
16.0 A  
Other rated currents on request  
Other rated currents on request  
Variants  
Rated current  
Construction variants  
Config. Code  
Order Number  
Auxiliary contact  
Shunt terminal  
Setting indication  
0.8 A  
1.0  
l
l
l
l
T12-211S-0.8  
T12-211SNR-1  
T12-211S-2.5  
T12-211S-6.5  
4410.0044  
4410.0655  
4410.0046  
4410.0264  
l
l
2.5 A  
6.5 A  
10.0 A  
12.0 A  
T12-211-10  
T12-211-12  
4410.0106  
4410.0019  
Most Popular.  
Availability for all products can be searched real-time:https://www.schurter.com/en/Stock-Check/Stock-  
Check-SCHURTER  
20 Pcs  
Packaging Unit  
Accessories  
Description  
T-Line Accessories  
Accessories to T-Line  
The specifications, descriptions and illustrations indicated in this document are based on current  
information. All content is subject to modifications and amendments. Information furnished is believed  
to be accurate and reliable. However, users should independently evaluate the suitability and test each  
product selected for their own applications.  
7
Circuit Breakers  

相关型号:

4410.0044

Circuit Breaker for Equipment thermal, Threaded neck type, Reset type, Quick connect terminals
SCHURTER

4410.0046

Circuit Breaker for Equipment thermal, Threaded neck type, Reset type, Quick connect terminals
SCHURTER

4410.0055

Thermal Magnetic Circuit Breaker
SCHURTER

4410.0106

Thermal Circuit Breaker,
SCHURTER

4410.0157

Thermal Magnetic Circuit Breaker,
SCHURTER

4410.0209

Thermal Circuit Breaker,
SCHURTER

4410.0215

Thermal Circuit Breaker,
SCHURTER

4410.0228

Thermal Magnetic Circuit Breaker
SCHURTER

4410.0264

Circuit Breaker for Equipment thermal, Threaded neck type, Reset type, Quick connect terminals
SCHURTER

4410.0525

Thermal Circuit Breaker,
SCHURTER

4410.0655

Circuit Breaker for Equipment thermal, Threaded neck type, Reset type, Quick connect terminals
SCHURTER

4410.0693

Thermal Circuit Breaker
SCHURTER