4
HIGH PERFORMANCE CBEs  
The AS168X is a thermal magnetic high performance CBE to IEC 934  
and a «supplementary protector» to UL 1077. It is capable of drasti-  
cally limiting the «let-through energy» in case of short circuit interrup-  
tions. The series is available in units from one to four poles for use in  
AC and DC circuits. Multi-pole devices are connected internally and at  
the handle for simultaneous operation. This applies also to combina-  
tions with the switched neutral pole. Well designed screw type term-  
inals at line and load side are provided for safe and easy connection  
to line and load. They accept #16 to 4 AWG / 1,5 to 25 mm2.  
AS168X Series  
• Excellent short circuit and  
energy limiting performance  
• AC and DC versions  
Accessories  
• Auxiliary contact module  
Each auxiliary contact module contains one contact,  
either normally open or normally closed.  
• Signal contact module  
Signal contact modules are linked internally with the protected  
poles but not linked at the handles.Contacts are actuated by a fault  
condition at the protected poles, not by the manual operation of  
the CBE.  
• Relay trip module  
The relay trip module can be used for remote tripping of the  
adjacent poles by applying a voltage to the module’s terminal.  
• Switched neutral pole (factory assembled)  
This module permits an automatic opening of the neutral line when  
the protected poles have been tripped.  
Features  
• Excellent short circuit performance (up to 10 kA)  
• High limits of discrimination (due to energy limitation)  
• Wide choice of characteristics (Adaptability)  
• Availability of AC and DC in the same frame size  
• Compact, «finger safe» design  
• Ease of installation (on DIN rail)  
• Worldwide approvals  
Schurter, Inc. Phone 707-778-6311 • Fax 707- 778-6401 • E-mail info@schurterinc.com • Website http://www.schurterinc.com 273  
4
HIGH PERFORMANCE CBEs AS168X  
Effect of ambient  
temperature  
The unit is calibrated for an ambient tem-  
perature of +23°C. To determine the rated  
current for a lower or higher ambient  
temperature, use a correction factor from  
the table below:  
Ambient  
Correction factor  
temperature [°C]  
–20  
–5  
0,80  
0,87  
0,90  
0,95  
1,00  
1,05  
1,10  
1,20  
1,30  
0
+10  
+23  
+30  
+40  
+50  
+60  
Example  
Rated current at +23°C  
Ambient temperature  
Correction factor  
10 A  
+50°C  
1,2  
Chosen rated current at  
+50°C ambient temperature  
10 A x 1,2 = 12 A  
Tripping characteristic F  
Tripping characteristic G  
Tripping characteristic H  
1hr  
1hr  
1hr  
1000s  
1000s  
1000s  
100s  
10s  
1s  
100s  
10s  
1s  
100s  
10s  
1s  
0,1s  
10ms  
1ms  
0,1s  
10ms  
1ms  
0,1s  
10ms  
1ms  
0,1ms  
0,1ms  
0,1ms  
1
1
10  
100  
1000 x I  
1
10  
100  
1000 x I  
10  
100  
1000 x I  
n
n
n
Multiple of rated current (x I  
)
Multiple of rated current (x I  
)
Multiple of rated current (x I  
)
n
n
n
Schurter, Inc. Phone 707-778-6311 • Fax 707- 778-6401 • E-mail info@schurterinc.com • Website http://www.schurterinc.com 279  
4
HIGH PERFORMANCE CBEs AS168X  
Tripping characteristic DF  
Tripping characteristic DG  
Tripping characteristic DH  
1hr  
1hr  
1hr  
1000s  
1000s  
1000s  
100s  
10s  
1s  
100s  
10s  
1s  
100s  
10s  
1s  
0,1s  
10ms  
1ms  
0,1s  
10ms  
1ms  
0,1s  
10ms  
1ms  
0,1ms  
0,1ms  
0,1ms  
1
1
1
10  
100  
1000 x I  
10  
100  
1000 x I  
10  
Multiple of rated current (x I )  
n
100  
1000 x I  
n
n
n
Multiple of rated current (x I  
)
Multiple of rated current (x I  
)
n
n
Technical data  
Pole:  
Rated voltage U  
e
AC versions F; G; H  
AC 480/277 V; DC 65 V  
DC versions DF; DG; DH  
DC 180 V 1 pole  
DC 360 V 2 – 4 pole  
Note: The connection polarity must be strictly  
observed. An application with a DC Type AS168X  
in an AC network is not admissible.  
Rated current I  
n
See approvals, page 282  
AC/DC 0,5 – 50 A  
10,000 A  
Short circuit capacity  
Endurance  
Max. I  
cn  
Number of operating cycles at I  
n
6000  
Type of tripping  
• Thermal magnetic  
• Positively trip-free  
Type of actuation  
Manual ON/OFF  
S-type  
2
Permissible wire cross section  
1,5 – 25 mm  
Switched neutral:  
Rated voltage U  
e
Rated current I  
n
AC 277 V  
AC/DC 65 A  
Function  
The switched neutral pole contact  
closes before and opens after the  
protected poles. Automatic activation is  
effected by the protected poles, manual  
actuation by the linked handles.  
280 Schurter, Inc. Phone 707-778-6311 • Fax 707-778-6401 • E-mail info@schurterinc.com • Website http://www.schurterinc.com  
4
HIGH PERFORMANCE CBEs AS168X  
Technical data (continued)  
Add-on modules:  
Rated voltage U  
AC 277 V  
Rated current I  
6 A  
e
n
Auxiliary contact H1 & H2 and  
Signal contact S1 & S2  
Functional auxiliary contact module  
Type H1 (assumes the same contact position)  
Type H2 (assumes the opposite position)  
Actuation of the contact is determined  
by the condition of the handle position  
of the adjacent poles.  
Functional signal contact  
Relay trip module  
Type S1 (assumes the same contact position)  
Type S2 (assumes the opposite position)  
The signal contact operates due to a  
thermal magnetic tripping and must  
be reset by hand.  
Type  
Voltage range AC/DC  
Impedance at 50/60 Hz  
A1  
A2  
A3  
A4  
A5  
5 – 12 V  
10 – 24 V  
20 – 48 V  
40 – 110 V  
90 – 240 V  
1.1  
4.7 Ω  
16 Ω  
63 Ω  
395 Ω  
Function of relay trip module  
The module allows remote tripping by  
applying a voltage between the  
terminals. Operating time 8 – 16 ms.  
General data:  
Dielectric strength  
AC 2000 V  
Vibration resistance  
0,75 mm amplitude, 10 – 57 Hz  
Shock resistance  
Waveform 11 ms  
25 g  
IP20  
Protection against electric shock  
Finger safe per IEC 529  
Permissible ambient temperature  
Weight  
-20°C to +60°C  
1 pole  
ca. 130 g  
ca. 130 g  
ca. 100 g  
ca. 100 g  
ca. 120 g  
Switched neutral  
Auxiliary contact  
Signal contact  
Relay trip module  
Schurter, Inc. Phone 707-778-6311 • Fax 707- 778-6401 • E-mail info@schurterinc.com • Website http://www.schurterinc.com 281  
4
HIGH PERFORMANCE CBEs AS168X  
Approvals  
Number of  
Rated current range  
Rated voltage  
Rated current range  
Rated voltage  
protected poles  
AC  
AC  
DC  
DC  
UL  
1077  
1
2
3
4
0,5 – 50 A  
0,5 – 50 A  
0,5 – 50 A  
0,5 – 50 A  
277 V  
0,5 – 40 A  
0,5 – 40 A  
0,5 – 40 A  
180 V  
360 V  
360 V  
480 V  
480 V  
480 / 277 V  
CSA 22.2 / 235  
1
2
3
4
0,5 – 50 A  
0,5 – 50 A  
0,5 – 50 A  
0,5 – 50 A  
277 V  
0,5 – 40 A  
0,5 – 40 A  
0,5 – 40 A  
180 V  
360 V  
360 V  
480 V  
480 V  
480 / 277 V  
VDE 0642  
1
2
3
4
0,5 – 40 A  
0,5 – 40 A  
0,5 – 40 A  
0,5 – 40 A  
420/240 V  
420 V  
0,5 – 40 A  
0,5 – 40 A  
0,5 – 40 A  
120 V  
240 V  
360 V  
420 V  
420/240 V  
282 Schurter, Inc. Phone 707-778-6311 • Fax 707-778-6401 • E-mail info@schurterinc.com • Website http://www.schurterinc.com  
4
HIGH PERFORMANCE CBEs AS168X  
Order code  
Basic type  
Thermal magnetic high performance circuit breaker  
Number of poles  
1
2
3
4
Tripping characteristics  
AC + DC thermal  
AC magnetic  
DC magnetic  
Available currents  
F
G
H
DF  
3 – 5 xI  
n
0,5 – 50 A  
0,5 – 50 A  
0,5 – 50 A  
0,5 – 40 A  
0,5 – 40 A  
6,0 – 40 A  
Hold  
1,05 xI / >1h  
n
6 – 10 xI  
n
12 – 20 xI  
n
4,5 – 8 xI  
n
DG Tripping  
DH 1,35 xI / <1h  
9 – 16 xI  
n
18 – 32 xI  
n
n
Rated current  
Code  
I
(A)  
Code  
I
(A)  
Code  
I
(A)  
Code  
I (A)  
n
n
n
n
005  
010  
015  
020  
030  
040  
050  
0.5  
060  
070  
080  
090  
100  
120  
150  
6.0  
160  
180  
200  
230  
250  
270  
300  
16.0  
18.0  
20.0  
23.0  
25.0  
27.0  
30.0  
320  
350  
400  
450  
500  
32.0  
35.0  
40.0  
45.0  
50.0  
1.0  
1.5  
2.0  
3.0  
4.0  
5.0  
7.0  
8.0  
9.0  
10.0  
12.0  
15.0  
Switched neutral pole  
N
Maximum  
combination  
AS168X – CB  
2
DG 200  
N
AS168X – ACB S2  
1 Add-on module  
+
4 poles  
+
N
2 Add-on modules + 3 poles + N  
Auxiliary contact  
H1 Assumes the same contact position as the protected poles  
H2 Assumes the opposite contact position as the protected poles  
Signal contact  
S1 Assumes the same contact position as the protected poles  
S2 Assumes the opposite contact position as the protected poles  
Relay trip module  
A1 AC/DC 5 – 12 V  
A2 AC/DC 10 – 24 V  
A3 AC/DC 20 – 48 V  
A4 AC/DC 40 – 110 V  
A5 AC/DC 90 – 240 V  
Accessories  
Must be ordered separately  
Schurter, Inc. Phone 707-778-6311 • Fax 707- 778-6401 • E-mail info@schurterinc.com • Website http://www.schurterinc.com 283  
4
HIGH PERFORMANCE CBEs AS168X  
DIN rail mounting  
AS168X-CB1…  
45  
…N  
17.5+00..50  
17.5+00..50  
35  
1.9  
90  
35 mm DIN rail EN 50022  
Max. torque  
Wire crosssection Max. torque  
1.5…10 mm2  
16 …25 mm2  
2.5 Nm  
3.1 Nm  
AS168X-ACBH.  
AS168X-ACBA.  
AS168X-ACBS.  
+0.5  
17.5+00..50  
17.5–0.0  
17.5+00..50  
Schematic diagrams  
AS168X-CB1…  
AS168X-CB1…N  
AS168X-CB1…  
AS168X-ACBH1  
AS168X-CB1…  
AS168X-ACBH2  
AS168X-CB1…  
AS168X-ACBS1  
AS168X-CB1…  
AS168X-ACBS2  
AS168X-CB1…  
AS168X-ACBA.  
284 Schurter, Inc. Phone 707-778-6311 • Fax 707-778-6401 • E-mail info@schurterinc.com • Website http://www.schurterinc.com  

相关型号:

AS168X-ACB2DF010N

Power Supply Module
SCHURTER

AS168X-ACB2DG160N

Power Supply Module
SCHURTER

AS168X-ACB2DG250N

Power Supply Module
SCHURTER

AS168X-ACB2DG450N

Power Supply Module
SCHURTER

AS168X-ACB2DH090N

Power Supply Module
SCHURTER

AS168X-ACB2DH270N

Power Supply Module
SCHURTER

AS168X-ACB2DH400N

Power Supply Module
SCHURTER

AS168X-ACB2F015N

Power Supply Module
SCHURTER

AS168X-ACB2F120N

Power Supply Module
SCHURTER

AS168X-ACB2F180N

Power Supply Module
SCHURTER

AS168X-ACB2F300N

Power Supply Module
SCHURTER

AS168X-ACB2F320N

Power Supply Module
SCHURTER