AXG4H100U1 [SCHURTER]
AXG4H100U1;型号: | AXG4H100U1 |
厂家: | SCHURTER INC. |
描述: | AXG4H100U1 |
文件: | 总8页 (文件大小:173K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
3
CIRCUIT BREAKERS FOR EQUIPMENT
The rocker actuated, 3 pole version with 2 protected poles is a
thermal CBE of the TA45 line, specifically designed to provide cost
effective protection of 3 phase motors against overheating in
accordance with EN60204 Part I (Electrical equipment for industrial
machines) in cases where the exception specified in this standard is
applicable.
TA45: 3 pole, rocker actuated
• Thermal release
• Positively trip-free
A special version is available as a «CBE-switch», in which the means
for automatic overcurrent interruption (the bimetal releases), are
omitted.
Another available version of this line utilizes an under-voltage release
to protect persons against injuries caused by unexpected events like
the automatic restarting of motors after a power failure. This release
can be combined with the thermal release required for overcurrent
protection. Protection against injuries is also provided by another CBE
of this line, which prevents the starting of a machine should a
protective cover be removed from dangerous parts of the machine.
Available options:
• CBE for overcurrent protection
2 protected poles (thermal)
• CBE with undervoltage release:
The CBE will open automatically when the voltage drops
below the trip level. Only when the supply voltage has reached
the reset level, the CBE can be re-closed manually.
• CBE switch with mechanical lock-out latch:
A spring loaded pin will trip the CBE if a protective cover is
removed. The CBE can not be switched ON until the
protective cover is refitted.
• CBE with remote trip release:
The remote trip release permits the CBE to be tripped by a
external contact (sensor) energizing the trip coil.
• CBE with auxiliary contact:
All types of the line can be with an auxiliary contact
(changeover contact).
TA45 is positively trip-free. The approved current range is 0,1 to 12A.
We recommend to limit the current range to max. 8A at AC 400V.
For the current range 9 to 12A the voltage should be limited to AC
240V. The CBE comes with snap-in mounting. The rocker is available
in various colors and also with illumination. It is approved in all major
industrial countries and complies with the CBE-standard EN60934. In
conjunction with its accessories the TA45 product line of Schurter
paves the way for new unconventional applications.
Applications
• Motors
• Power supplies
• Processing machines
• etc.
254 Schurter, Inc. Phone 707-778-6311 • Fax 707-778-6401 • E-mail info@schurterinc.com • Website http://www.schurterinc.com
•
3
CIRCUIT BREAKERS FOR EQUIPMENT TA45, 3 POLE
Effect of ambient
temperature
The unit is calibrated for an ambient tem-
perature of +23°C. To determine the rated
current for a lower or higher ambient
temperature, use a correction factor from
the table below:
*Ambient
Correction factor
temperature [°C]
-10
-5
0,89
0,91
0,92
1,00
1,03
1,08
1,16
0
+23
+30
+40
+55
Example
Rated current at +23°C
Ambient temperature
Correction factor
5,0 A
+40°C
1,08
Chosen rated current at
+40°C ambient temperature
5 A x 1,08 = 5,5 A
*Temperature must be measured at the rear of the
breaker next to the terminals after equipment operating
temperature has been reached.
Tripping characteristic
Tripping characteristic
3 A ≥ I ≤12 A
I <3 A
n
n
[ min ] [ sec ]
10'000
[ min ] [ sec ]
10'000
Type
Rated current
TA45
I <3 A
n
Type
Rated current
TA45
3 A ≥ I ≤12 A
n
60
60
3 pole switch
2 pole protected
+23 °C
3 pole switch
2 pole protected
2`000
1`00
500
2`000
30
30
20
20
10
5
Ambient temp.
+23 °C
1`00
500
Ambient temp.
10
5
200
100
50
200
100
50
1
1
20
10
5
20
10
5
2
1
2
1
0,5
0,5
0,3
0,2
0,3
0,2
0,1
0,1
1,05 1,32
2
3
4
5
8
10
n
1,05 1,32
2
3
4
5
8
10
n
Tripping time
[ x I
Multiple of rated current
[ x I
Schurter, Inc. Phone 707-778-6311 • Fax 707- 778-6401 • E-mail info@schurterinc.com • Website http://www.schurterinc.com 255
•
3
CIRCUIT BREAKERS FOR EQUIPMENT TA45, 3 POLE, ROCKER
Technical data
Rated voltage Ue
See approvals page 257
See approvals page 257
AC 400 V
Rated current In
AC 0,1 A – 12 A
Short circuit capacity I
Degree of protection
AC 400 V with I
(number of cycles: 3)
10 I
n
cn
n
Accessible range
With accessories
Terminal side
IP40
IP40, IP65
IP00
Dielectric strength
Insulation resistance
Endurance
Accessible range
DC 500 V
AC 4000 V
>100 MΩ
Number of cycles at I (AC 400 V)
n
Number of cycles at 6 x I (AC 400 V)
n
50’000 x
40 x
Permissible ambient temperature
Resistance to vibration
Shock resistance
-10°C to +55°C
>10 g
IEC 68-2-6, test Fc, 1mm amplitude 5-60 Hz, 60-500 Hz
IEC 68-2-6, test Ea
>30 g
Type of tripping
• Termal positively trip-free
• Undervoltage release
• Remote trip
• Mechanical lock-out latch
Weight
approx. 35 g
AC 240 V
Auxiliary contact (changeover)
Rated voltage
DC 28 V
DC 60 V
Rated current
max. 10 A
max. 2 A
max. 2 A
resistive load
resistive load
cos ϕ 0.7 (PF 0.7)
256 Schurter, Inc. Phone 707-778-6311 • Fax 707-778-6401 • E-mail info@schurterinc.com • Website http://www.schurterinc.com
•
3
CIRCUIT BREAKERS FOR EQUIPMENT TA45, 3 POLE
Technical data (continued)
Undervoltage release
Max. operating voltage
1,1 U
e
Rated operating voltage Ue
Current consumption (±10%)
Highest reset level
5 V
12 V
24 V
48 V
120 V
240 V
400 V
10,5 mA 16,5 mA 17,0 mA 3,2 mA
3,7 mA
2,8 mA
2,65 mA
0,85 U
e
Lowest trip level
0,20 U
e
Trip delay
20 ms – 50 ms
Impulse with stand voltage (1,2 / 50 µs)
≥4 kV
Remote trip
Permissible impulse duration
of the make contact (n/o)
(Between terminal C and P1)
unlimited
Electrical load
of the make contact (n/o)
Current max. 12 mA / power max. 1,1 W
Approvals
Rated current range
AC
Rated voltage
AC
VDE
EN60934
EN60934
EN60934
0,1 – 12 A*
400 V
400 V
400 V
SEMKO
SEV
0,1 – 12 A*
0,1 – 12 A*
* The approved current range is 0,1 to 12 A. We recommend to limit the range to max. 8 A at AC 400V. For the current range 9 to 12 A
the voltage should be limited to AC 240 V.
Schurter, Inc. Phone 707-778-6311 • Fax 707- 778-6401 • E-mail info@schurterinc.com • Website http://www.schurterinc.com 257
•
3
CIRCUIT BREAKERS FOR EQUIPMENT TA45, 3 POLE, ROCKER
Order code 3 pole, rocker actuated
Basic type
Without thermal overload protection
Auxiliary contact (changeover)
Shunt terminal
•
7
P2
P1
P2
P1 11101
6
5
9
6
5
9
12
Terminal type
Snap-in type
Quick connect terminal
Screw type terminal (lineside P1, P2)
•
•
•
•
Dimensions
Page
260
AKC
AC1
ALC
261
AMC
A1C
ANC
260
AVC
AS1
AWC
261
AXC
A1S
AYC
ON/OFF switch
Without illumination
With illumination
Without illumination
380 V…400 V
Impulse switch
Order example
Colors
Switch front
Rocker
AKD W
F
030 U1
W
1
B
R
3
G
4
Y
X
6
black
black
black
black
black
black
black
black
black
black
white
–
black
red
–
green
–
yellow
orange
–
–
clear transp.
–
–
red transp.
–
green transp.
–
–
orange transp.
Rocker legend
Surface
Without thermal overload protection: code C00
With thermal overload protection: rated current I (A)
n
Illustration Color of print
Other amperages available on request.
I
Code
I
Code
I
Code
I
n
Code
n
n
n
F
embossed
printed
printed
printed
printed
printed
printed
printed
printed
4,0
4,5
5,0
6,0
6,5
7,0
7,5
8,0
040
045
050
060
065
070
075
080
H
K
L
white
black
white
black
white
black
white
black
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
J01
J02
J03
J04
J05
J06
J07
J08
J09
1,9
2,0
2,1
2,2
2,3
2,5
2,8
3,0
3,5
J19
J20
J21
J22
J23
J25
J28
030
035
1,0
1,1
1,2
1,3
1,4
1,5
1,6
1,7
1,8
J10
J11
J12
J13
J14
J15
J16
J17
J18
M
P
R
S
T
I
I
0
0
9,0* 090
* The approved current range is 0,1 to 12 A. We recommend to limit the
range to max. 8 A at AC 400 V. For the current range 9 to 12 A the vol-
tage should be limited to AC 240 V.
10,0* 100
11,0* 110
12,0* 120
258 Schurter, Inc. Phone 707-778-6311 • Fax 707-778-6401 • E-mail info@schurterinc.com • Website http://www.schurterinc.com
•
3
CIRCUIT BREAKERS FOR EQUIPMENT TA45, 3 POLE
1 pole thermal overload protection
2 pole thermal overload protection
•
•
•
•
P2
P1
7
1110
P1 7 11
P2
P1 7 11110
P2
P1
7
P2
3
4
3
4
3
4
4
3
6
5
9
12
9
•
12
9
6
5
9
•
•
•
•
•
•
•
260
AKD
AD1
ALD
261
AMD
A1D
AND
260
AKG
AG1
ALG
261
260
AVD
AW1
AWD
261
260
261
AMG
A1G
ANG
AXD
A1W
AYD
AVG
AX1
AXG
A1X
AYG
AWG
Detail see pages 224-225
Without release / lock-out latch: code C0
Undervoltage release
Remote trip release
Mechanical lock-out latch
P2
P1
7
P2
P1
7
P1
P2
7
P2
P1
7
P2
P1
7
c
b
b a
U<
U<
U<
6
5
9
6
5
9
6
5
9
6
5
9
6
5
9
Rated voltage U
AC (V)
n
U*
•
E*
Z
A*
Code
S0
1
2
3
4
400
•
•
•
•
•
•
•
•
240
230
120
AC / DC (V)
6
7
8
9
48
24
12
5
•
•
•
•
* Release U, E and A not available in combination with screw clamp terminals (basic type)
Schurter, Inc. Phone 707-778-6311 • Fax 707- 778-6401 • E-mail info@schurterinc.com • Website http://www.schurterinc.com 259
•
3
CIRCUIT BREAKERS FOR EQUIPMENT TA45, 3 POLE, ROCKER
Quick connect terminals
Basic type
36.5
16
48
23.7
9
43.6
10
11
12
7
10.8 11
33
8.4
7.6 7.5
5.3
11.6
Quick connect terminal
DIN 46244 A6,3–0,8
Undervoltage release, remote trip release
48
36.5
16
23.7
9
43.6
10.8
15.5
11
10
11
12
7
1.5
Quick connect terminal
DIN 46244 A6,3–0,8
10.8
21.5
22
6.3
8.4
5.3
7.6 7.5
11.6
33
Quick connect terminal
DIN 46244 A2,8–0,8
Mechanical lock-out latch
48
36.5
16
23.7
43.6
3
9
10.8
11
10
11
12
7
2
Quick connect terminal
DIN 46244 A6,3–0,8
22.8
17.5
19.5
5.3
7.6 7.5 8.4
11.6
5.5
33
260 Schurter, Inc. Phone 707-778-6311 • Fax 707-778-6401 • E-mail info@schurterinc.com • Website http://www.schurterinc.com
•
3
CIRCUIT BREAKERS FOR EQUIPMENT TA45, 3 POLE
Screw clamp terminal
Basic type
10.8
10
9
10
11
12
7
5.3
Screw type M3,5x6 (Philips Form H)
Maximum torque 1 Nm
Cut-out and pin-out
Pin-out
U-Relais
Cut-out
a
b
P2
b
P1
1.0
1.5
2.0
2.5
3.0
4.0
5.0
44,5...45,0
44,5...45,0
44,7...45,2
44,7...45,2
44,8...45,3
44,9...45,4
45,0...45,5
7
Auxiliary contact / 3 pole
a
10
11
c
4
6
12
b
3
9
5
Assembly
edge must be sharp
Schurter, Inc. Phone 707-778-6311 • Fax 707- 778-6401 • E-mail info@schurterinc.com • Website http://www.schurterinc.com 261
•
相关型号:
©2020 ICPDF网 联系我们和版权申明