CEG0.6100.151.21 [SCHURTER]

Mains Power Connector;
CEG0.6100.151.21
型号: CEG0.6100.151.21
厂家: SCHURTER INC.    SCHURTER INC.
描述:

Mains Power Connector

连接器
文件: 总5页 (文件大小:592K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Power Entry Modules with Line Filter  
www.schurter.com/PG06  
CE  
IEC Appliance Inlet C14 with Filter, Fuseholder 1-or 2-pole (5 x 20 mm or 6.3x32 mm, with or without vol-  
tage selector (series-parallel)  
Standard- or Medical-Filter  
Fuse drawer and voltage selector insert must be  
ordered separately.  
C14  
70° C  
Description  
- Panel Mount:  
Characteristics  
- All single elements are already partially wired  
- For added safety "Extra-Safe" fuse drawers are available  
Fuse drawer meets requirements of medical standard IEC/EN 60601-1  
The fuse drawer can only be opened with the aid of a tool  
The fuseholder is accessible from the equipment front  
- Suitable for use in equipment according to IEC/UL 60950  
Suitable for use in medical equipment according to IEC/UL 60601-1  
Screw-on mounting from front side  
- 4 Functions:  
Appliance Inlet, Fuseholder with interchangeable fuse drawer for Fuse-  
links 5x20 mm or 6.3x32 mm 1 or 2 pole, Voltage Selector (series-  
parallel), Line filter in standard and medical version  
- Quick connect terminals 4.8 x 0.8 mm  
References  
Alternative: version without line filter KE  
Alternative: Standard version  
Approvals  
- VDE Certificate Number: 40004665 (FKA, FKB)  
- UL File Number: E72928 (FKA, FKB)  
Weblinks  
pdf-datasheet, html-datasheet, General Product Information, Approvals,  
CE declaration of conformity, RoHS, CHINA-RoHS, Mating Connectors,  
e-Shop, SCHURTER-Stock-Check, Distributor-Stock-Check, CAD-  
Drawings, Accessories, Detailed request for product  
Newly available variants corresponding to V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset.  
The cord latching system prevents against accidental removal of the cordset.  
Technical Data  
Ratings IEC  
Ratings UL/CSA  
Leakage Current  
1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz  
1 - 10 A @ Ta 40 °C / 125 VAC; 60 Hz  
standard < 0.5 mA (250 V / 60 Hz)  
medical < 5 µA (250 V / 60 Hz)  
> 1.7 kVDC between L-N  
> 2.7 kVDC between L/N-PE  
Test voltage (2 sec)  
-25 °C to 85 °C  
25/085/21 acc. to IEC 60068-1  
from front side IP 40 acc. to IEC 60529  
Suitable for appliances with protection  
class I acc. to IEC 61140  
Quick connect terminals 4.8 x 0.8 mm  
Screw: max 8 mm  
Appliance-Inlet/-Outlet  
Fuseholder  
C14 acc. to IEC 60320,  
UL 498, CSA C22.2 no. 42 (for cold  
conditions) pin-temperature 70 °C,  
10 A, Protection Class I  
1 or 2 pole, Shocksafe category PC2  
acc. to IEC 60127-6,  
for fuse-links 5 x 20 or 6.3 x 32 mm  
5 x 20: 2.5 W (1 pole)/ 2 W (2-pole) per  
pole  
6.3 x 32: 3.15 W (1 pole)/ 2.5 W (2-pole)  
per pole  
Admissible power acceptance at higher  
ambient temperature see derating cur-  
ves  
series-parallel, 4, 3 or 2 switch positions  
or usable as 2-pole change-over switch  
Standard and Medical Version, IEC  
60939, UL 1283, CSA C22.2 no. 8  
Technical Details  
Dielectric Strength  
Rated Power Acceptance @  
Ta 23 °C  
Allowable Operation Temp.  
Climatic Category  
Degree of Protection  
Protection Class  
Power Acceptance @ Ta >  
23°C  
Terminal  
Panel Thickness s  
Voltage Selector  
Line Filter  
Mounting screw torque max 0.5 Nm  
Thermoplastic, black, UL 94V-0  
Material: Housing  
MTBF  
> 1'400'000 h acc. to MIL-HB-217 F  
1
EMC Products  
Power Entry Modules with Line Filter  
CE  
www.schurter.com/PG06  
Dimensions  
55  
30  
R 6  
M3/ø 3.6  
2
4.8x0.8  
R 4.5  
0
-0.2  
R 3  
4.8x0.8  
56  
69  
R 3.1  
2.8  
28.5+0.3  
0
27.2  
Technical Data of Filter-Components  
Rated Current  
[A]  
Filter-Type  
Inductances Capacitance Capacitance  
R [M]  
L [mH]  
CX [nF]  
CY [nF]  
1
2
Standard Version  
2 x 10  
2 x 4  
68  
68  
68  
68  
68  
68  
68  
68  
68  
68  
68  
2.2  
2.2  
2.2  
2.2  
2.2  
-
-
-
Standard Version  
4
Standard Version  
2 x 1.5  
2 x 0.8  
2 x 0.3  
2 x 10  
2 x 4  
-
6
Standard Version  
-
10  
1
Standard Version  
-
Medical Version (M5)  
Medical Version (M5)  
Medical Version (M5)  
Medical Version (M5)  
Medical Version (M5)  
Medical Version (M80)  
1
1
1
1
1
1
2
-
4
2 x 1.5  
2 x 0.8  
2 x 0.3  
2 x 4  
-
6
-
10  
2
-
0.47  
Diagrams  
Standard version  
Medical version  
5
6
5
3
4
X)  
X)  
3
4
X)  
X)  
Voltage  
Selector  
Voltage  
Selector  
L
1)  
PE  
L
1)  
PE  
6
7
L1  
L1  
L2  
F1  
PE’  
F2  
F1  
PE’  
F2  
2)  
2)  
7
Cy  
Cy  
R
8
8
Cx  
L2  
Cx  
9
9
10  
10  
N
N
1) Line  
2) Load  
1) Line  
2) Load  
x) External connection to be made by the customer  
x) External connection to be made by the customer  
2
EMC Products  
Power Entry Modules with Line Filter  
www.schurter.com/PG06  
CE  
Derating Curves  
Fuses  
Fuses  
Fuses  
Fuses  
5 x 20 mm (1-pole)  
5 x 20 mm (2-pole, per pole)  
6.3 x 32 mm (1-pole)  
6.3 x 32 mm (2-pole, per pole)  
2.5  
2.0  
3.15  
2.5  
2.0  
2.0  
2.5  
1.5  
I = 1.0 In  
I = 1.0 In  
I = 1.0 In  
I = 1.0 In  
I = 0.7 In  
I = << In  
2.0  
1.5  
1.5  
I = 0.7 In  
I = 0.7 In  
I = 0.7 In  
1.0  
1.5  
1.0  
0.5  
I = << In  
1.0  
I = << In  
1.0  
I = << In  
0.5  
0.5  
0.0  
0.5  
0.0  
0.0  
0.0  
0
20  
40  
60  
80  
100  
0
20  
40  
60  
80  
100  
0
20  
40  
60  
80  
100  
0
20  
40  
60  
80  
100  
Ambient air temperature Ta °C  
Ambient air temperature Ta °C  
Ambient air temperature Ta °C  
Ambient air temperature Ta °C  
- - - - differential mode _____ common mode  
Attenuation Loss  
Standard version  
1 A  
2 A  
4 A  
6 A  
10 A  
Medical version (M5)  
1 A  
2 A  
4 A  
6 A  
10 A  
10 Pcs  
Packaging unit  
3
EMC Products  
Power Entry Modules with Line Filter  
CE  
www.schurter.com/PG06  
Variants  
Rated Current  
[A]  
Filter-Type  
Fuseholder  
Order Number  
1
2
Standard Version  
Standard Version  
Standard Version  
Standard Version  
Standard Version  
Standard Version  
Standard Version  
Standard Version  
Standard Version  
Standard Version  
Medical Version (M5)  
Medical Version (M5)  
Medical Version (M5)  
Medical Version (M5)  
Medical Version (M5)  
1-pole  
1-pole  
1-pole  
1-pole  
1-pole  
2-pole  
2-pole  
2-pole  
2-pole  
2-pole  
2-pole  
2-pole  
2-pole  
2-pole  
2-pole  
CE16.5100.151  
CE26.5100.151  
CE36.5100.151  
CE46.5100.151  
CE66.5100.151  
CE10.6100.151  
CE20.6100.151  
CE30.6100.151  
CE40.6100.151  
CE60.6100.151  
CEG0.6100.151  
CEA0.6100.151  
CEC0.6100.151  
CEE0.6100.151  
CEL0.6100.151  
4
6
10  
1
2
4
6
10  
1
2
4
6
10  
Most Popular.  
Availability for all products can be searched real-time:http://www.schurter.com/en/Stock-Check/  
Stock-Check-SCHURTER  
Suffix ".21" corresponds to the version with V-Lock mating cordset. The connector is equipped  
with a notch intended for use with the latching cordset. The cord latching system prevents  
against accidental removal of the cordset.  
Required Accessory  
Description  
Jumper Wire 1  
Connection with Stranded Cable  
Type A, 70 mm  
Type A, 100 mm  
Type B, 70 mm  
Type B, 100 mm  
0881.0074  
0881.0075  
0881.0076  
0881.0077  
Fusedrawer 1  
Fusedrawer for Fuse Links 5x20 mm resp. 6.3x32 mm  
5 x 20, 2-pole  
5 x 20, 1-pole  
6.3 x 32, 2-pole  
6.3 x 32, 1-pole  
4305.0001  
4305.0006  
4305.0011  
4305.0016  
...  
Voltage Selectors Insert 1  
Voltage Selector Insert to KE, CE, KG, CG  
3 or 4 switch positions  
4305.0048.00  
4305.0048.01  
4305.0048.02  
4305.0048.03  
...  
1, 3 or 4 switch positions, 100, 120, 220, 240  
3, 3 or 4 switch positions, 130, 110, 240, 220  
2, 2 switch positions, 110, 220  
4
EMC Products  
Power Entry Modules with Line Filter  
www.schurter.com/PG06  
CE  
Accessories  
Assorted Covers  
Rear Cover  
0859.0108  
Cord retaining kits  
Cord retaining strain relief  
Flat head, A  
4700.0001  
Mating Outlets/Connectors  
Category / Description  
Appliance Outlet Overview complete  
IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder Terminal  
IEC Appliance Outlet F, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal  
IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal  
Appliance Outlet further types to CE  
4787  
4788  
5091  
Connector Overview complete  
IEC Connector C15A, Rewireable, Straight  
IEC Connector C15A, Rewireable, Straight  
IEC Connector C15A, Rewireable, Angled  
IEC Connector C13, Rewireable, Angled  
IEC Connector C13, Rewireable, Straight  
Connector further types to CE  
0102  
0102-G  
0112  
4012  
4022  
...  
The specifications, descriptions and illustrations indicated in this document are based on current  
information. All content is subject to modifications and amendments.  
5
EMC Products  

相关型号:

CEG1-1-51-30.0-A-91-V

CIR BRKR MAG-HYDR 30A 80VDC
ETC

CEG1-1REC4-31861-1-V

CIR BRKR MAG-HYDR LEVER
ETC

CEG1-1REC4-31968-1-V

CIR BRKR MAG-HYDR LEVER
ETC

CEG1-1REC4-33399-03-V

CIR BRKR MAG-HYDR LEVER
ETC

CEG1-1REC4-33399-05-V

CIR BRKR MAG-HYDR LEVER
ETC

CEG1-1REC4-33399-06-V

CIR BRKR MAG-HYDR LEVER
ETC

CEG1-1REC4-33399-10-V

CIR BRKR MAG-HYDR LEVER
ETC

CEG1-1REC4-33399-252-V

CIR BRKR MAG-HYDR LEVER
ETC

CEG1-1REC4-35302-1-V

CIR BRKR MAG-HYDR LEVER
ETC

CEG1-1REC4-51-5.00-01-V

CIR BRKR MAG-HYDR 5A 80VDC
ETC

CEG1-1REC5-35948-30-V

CIR BRKR MAG-HYDR LEVER
ETC

CEG1-1REC5-35948-4-V

CIR BRKR MAG-HYDR LEVER
ETC