DF12.0470.9310.1 [SCHURTER]
DF12 .ABDWF100C0.9310.1 15A M5;型号: | DF12.0470.9310.1 |
厂家: | SCHURTER INC. |
描述: | DF12 .ABDWF100C0.9310.1 15A M5 连接器 |
文件: | 总7页 (文件大小:688K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Power Entry Modules with Line Filter
DF12
https://www.schurter.com /PG06
IEC Appliance Inlet C14 or C18 with Filter, Circuit Breaker TA45 (recessed)
C14
C18
Approvals and Compliances
70° C
70° C
Description
Characteristics
- Panel Mount :
- All single elements are already wired
- Circuit Breaker non-illuminated or illuminated
- Suitable for use in equipment according to IEC/UL 60950
Screw-on mounting from front side
- 3 Functions :
Appliance Inlet protection class I or II , circuit breaker type TA45 2-pole
, Line filter in standard and medical version
- Quick connect terminals 6.3 x 0.8 mm
Suitable for use in medical equipment according to IEC/UL 60601-1
Other versions on request
- Unwired versions
- Other rocker marking
- Medical version M80
- Capacitance CX1
- Variant with notch for V-Lock mating Cordsets
References
Alternative: version without line filter DF11
Substitute for type 5145
Alternative: Standard version
Weblinks
pdf datasheet, html-datasheet, General Product Information, Distributor-
Stock-Check, Accessories, Detailed request for product, Microsite
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
1 - 10A @ Ta 40 °C / 250VAC; 50Hz
1 - 15A @ Ta 40 °C / 250VAC; 60Hz
standard < 0.5mA (250V / 60Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7kVDC between L-N
> 2.7kVDC between L/N-PE
Test voltage (2sec)
-10°C to 55°C
appliance inlet/-outlet
Circuit Breakers
C14 / C18 acc. to IEC 60320-1
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10A,
Protection Class I or II
Acc. IEC/EN 60934, UL 1077, CSA
22.2 no. 235
2-pole rocker switch, illuminated or non-
illuminated. Optional with undervoltage-
or remote trip release
Short circuit capacity Icn:
at In < 3A/240VAC : 10 x In
at In ≥ 3A/240VAC : 300A
Standard and Medical Version, IEC
60939, UL 1283, CSA C22.2 no. 8
Technical Details
Dielectric Strength
Allowable Operation Tempe-
rature
Climatic Category
IP-Protection
10/055/21 acc. to IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class I or II acc. to IEC 61140
Quick connect terminals 6.3 x 0.8 mm
Screw: max 8mm
Protection Class
Line Filter
MTBF
Terminal
Panel Thickness S
> 100'000h acc. to MIL-HB-217 F
Mounting screw torque max 0.5Nm
Material: Housing
Thermoplastic, black, UL 94V-0
Approvals and Compliances
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about
Approvals
1
EMC Products
Power Entry Modules with Line Filter
DF12
https://www.schurter.com /PG06
Approvals
The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.
Approval Reference Type: DF12
Approval Logo
Certificates
Certification Body
Description
VDE Approvals
VDE
Certificate Number: 40012935
UL Approvals
UL
UL File Number: E72928
Product standards
Product standards that are referenced
Organization
Design
Standard
Description
Designed according to
IEC 60320-1
Appliance couplers for household and similar general purposes
Designed according to
Designed according to
Designed according to
Designed according to
Designed according to
Designed according to
IEC 60939
Passive filters for suppressing electromagnetic interference
Switches for appliances. Part 1. General requirements
Standard for Attachment Plugs and Receptacles
Electromagnetic interference filters
IEC 61058-1
UL 498
UL 1283
CSA C22.2 no. 42
CSA C22.2 no. 8
General Use Receptacles, Attachment Plugs, and Similar Wiring Devices
Electromagnetic interference (EMI) filters
Application standards
Application standards where the product can be used
Organization
Design
Standard
Description
Designed for applications acc.
IEC/UL 60950
IEC 60950-1 includes the basic requirements for the safety of information
technologyequipment.
Designed for applications acc.
IEC 60601-1
Medical electrical equipment - Part 1: General requirements for basic
safety and essential performance
Compliances
The product complies with following Guide Lines
Identification
Details
Initiator
Description
CE declaration of conformity
SCHURTER AG
The CE marking declares that the product complies with the applicable
requirements laid down in the harmonisation of Community legislation on
its affixing in accordance with EU Regulation 765/2008.
RoHS
SCHURTER AG
SCHURTER AG
SCHURTER AG
EU Directive RoHS 2011/65/EU
China RoHS
REACH
The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March
2007. It is similar to the EU directive RoHS.
On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration,
Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as
"REACH") entered into force.
MicrositeV-Lock
SCHURTER AG
SCHURTER AG
V-Lock system are based on a matching plug-dose combination. The
connector is equipped with a notch intended for use with the latching
cordset. The cord latching system prevents against accidental removal of
the cordset.
Medical Equipment
Suitable for use in medical equipment according to IEC/UL 60601-1
2
EMC Products
Power Entry Modules with Line Filter
DF12
https://www.schurter.com /PG06
Dimension [mm]
Screw-on Version
76.2
33.5
28.7
10.6
41.2
36
2.8
29.4
0.8
5.3
Ø 3.3
Ø 6.4
29.8
0.10
30.8
9.7
47.2
* --- Version TA45 with undervoltage release
Technical Data of Filter-Components
Rated Current
[A]
Filter-Type
Inductances Capacitance Capacitance
R [MΩ]
L [mH]
CX [nF]
CY [nF]
1
2
Standard
2 x 11
2 x 4
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
-
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Standard
3
Standard
2 x 2.5
2 x 1.6
2 x 0.7
2 x 0.6
2 x 0.4
2 x 0.1
2 x 4
4
Standard
6
Standard
8
Standard
10
15
2
Standard
Standard
Medical (M5)
Medical (M5)
Medical (M5)
Medical (M5)
Medical (M5)
Medical (M5)
Medical (M5)
3
2 x 2.5
2 x 1.6
2 x 0.7
2 x 0.6
2 x 0.4
2 x 0.1
-
4
-
6
-
8
-
10
15
-
-
3
EMC Products
Power Entry Modules with Line Filter
DF12
https://www.schurter.com /PG06
Diagrams
Standard version
Medical version (M5)
L’
P1
P2
L’
P1
P2
L
1)
PE
L
1)
PE
L1
L2
L1
L2
2)
2)
Cy
Cy
R
PE’
N’
PE’
N’
Cx
Cx
N
N
1) Line
2) Load
1) Line
2) Load
- - - - 50Ω differential mode _____ 50Ω common mode
Attenuation Loss
Standard version
1 A
2 A
3 A
4 A
6 A
8 A
10 A
15 A
Medical version (M5)
1 A
2 A
3 A
4 A
6 A
8 A
10 A
15 A
4
EMC Products
Power Entry Modules with Line Filter
DF12
https://www.schurter.com /PG06
Table 1 Selection for type TA45
Order example
ABT
W
F
150
C0
• Circuit Breaker of Equipment
• 2-pole, rocker actuated
• Quick connect terminal
Other types on request
Diagram
1-pole
2-pole
Thermal overload protection
P2
P1
P2
P1
3
6
4
3
Without illumination
ABT
ABD
A12
A14
A32
A34
With illumination
220…240 V
110…120 V
}
Colours
Switch front
Rocker
W
B
6
black
black
black
white
black
–
–
–
orange transp.
Rocker legend
Surface
Illustration Colour of print
Surface
Illustration Colour of print
F
embossed / Relief
printed / bedruckt
printed / bedruckt
printed / bedruckt
M
P
printed
printed
printed
black
I
I
O
O
H
K
L
white / weiss
black / schwarz
white / weiss
white
black
R
Position of the rocker legend
e.g F
Rated current circuit breaker of equipment
I
Code
I
Code
I
Code
I
Code
n
n
n
n
10,0
11,0
12,0
13,0
14,0
15,0
20,0
100
110
120
130
140
150
200
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
1,0
1,1
1,2
J01
J02
J03
J04
J05
J06
J07
J08
J09
J10
J11
J12
2,8
3,0
3,5
4,0
4,5
5,0
6,0
6,5
7,0
7,5
8,0
9,0
J28
030
035
040
045
050
060
065
070
075
080
090
1,3
1,4
1,5
1,6
1,7
1,8
1,9
2,0
2,1
2,2
2,3
2,5
J13
J14
J15
J16
J17
J18
J19
J20
J21
J22
J23
J25
Without release: code C0
Undervoltage release
Remote trip release
P2
P1
P2
P1
P2
P1
P2
P1
c
b
b a
U<
U<
U<
Rated
voltage U
U
E
Z
A
Code
n
2
3
4
240 V AC
230 V AC
120 V AC
•
•
•
•
•
•
•
•
•
•
•
•
5
EMC Products
Power Entry Modules with Line Filter
DF12
https://www.schurter.com /PG06
Technical data (continued)
Circuit breaker
Tripping characteristics
In < 3 A
Tripping characteristics
In >_ 3… <_ 15 A
[ min ] [ sec ]
10’000
[ min ] [ sec ]
10’000
Typ
TA45
< 3 A
Typ
TA45
I > 3... < 15 A
n
Nennstrom
I
Nennstrom
n
60
60
1-polig geschützt
1-polig geschützt
2000
1000
500
2’000
30
30
20
2-polig geschützt
+23 °C
2-polig geschützt
+23 °C
20
1’000
Umgebungstemp.
Umgebungstemp.
10
5
10
500
5
200
100
50
200
100
1
1
50
20
10
5
20
10
5
2
1
2
1
0,5
0,5
0,3
0,2
0,3
0,2
0,1
0,1
1,05 1,32
2
3
4
5
8
10
1,05 1,32
2
3
4
5
8
10
Nennstrom-Vielfaches
[ x I
n
]
Nennstrom-Vielfaches
[ x I
n
]
1)
Effect of ambient temperature
* Temperature must be measured at the rear of the breaker next
to the terminals after equipment operating temperature has been
reached.
The unit is calibrated for an ambient temperature of +23 °C. To
determine the rated current for a lower or higher ambient tempera-
ture, use a correction factor from the table below.
1)
* Ambient temperature [°C] Correction factor
Example
–10
– 5
0
+23
+30
+40
+55
0,89
0,91
0,92
1,00
1,03
1,08
1,16
Rated current at +23 °C
Ambient temperature
Correction factor
Chosen rated current at
+ 40 °C ambient temperature
6,0 A
+40 °C
1,08
6 A x 1,08 = 6,5 A
Configuration code (example)
Optional Variants
00 standard
21 V-Lock notch
Type
Order code TA 45
(2-pole rocker-switch
without accessories)
Colour
0 black
DF12 - ABTWF150C0 - 000 - 1111 - 00 - 21
see table 1
Mounting
0 Screw mounting
Terminal PE
0 without (PCII)
1 QC 6.3x0.8
Terminal L and N
1 QC 6.3x0.8, without connection to TA45
3 Connection to TA45 non insulated
Type of mains filter / capacitor / bleed resistor
1 standard
3 medical M5
X2, Y2
X2
with bleed resistor
with bleed resistor
Rated current 1)
1
2
3
4
5
6
7
9
1A
2A
3A
4A
6A
8A
10A
15A
1) The rated current of the line-filter must be equal
or more than the rated current of TA45
20 Pcs
Packaging unit
6
EMC Products
Power Entry Modules with Line Filter
DF12
https://www.schurter.com /PG06
Accessories
Description
Assorted Covers
Rear Cover
0859.0109
Mating Outlets/Connectors
Category / Description
Appliance Outlet Overview complete
IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder Terminal
IEC Appliance Outlet F, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal
IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal
Appliance Outlet further types to DF12
4787
4788
5091
Connector Overview complete
4782 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13
4022 Mounting: Power Supply Cord, 3 x 1.5 mm², Screw clamps, Connector: IEC C13
4785 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13
4300-06 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13
4012 Mounting: Power Supply Cord, 3 x 1.5 mm², Screw clamps, Connector: IEC C13
Connector further types to DF12
4782
4022
4785
4300-06
4012
...
Mating Outlets/Connectors shuttered
Power Cord Overview complete
VAC13KS, Overview, diverse Connector IEC C13, cord end:
Power Cord further types to DF12
VAC13KS
The specifications, descriptions and illustrations indicated in this document are based on current
information. All content is subject to modifications and amendments. Information furnished is believed
to be accurate and reliable. However, users should independently evaluate the suitability and test each
product selected for their own applications.
7
EMC Products
相关型号:
DF12.A026F150C0.1110.1
Mains Power Connector, 1A, 250VAC, Male, Solder Terminal, ROHS COMPLIANT
SCHURTER
DF12.A026F150C0.1110.2
Mains Power Connector, 1A, 250VAC, Male, Solder Terminal, ROHS COMPLIANT
SCHURTER
DF12.A026F150C0.1310.1
Mains Power Connector, 1A, 250VAC, Male, Solder Terminal, ROHS COMPLIANT
SCHURTER
DF12.A026F150C0.1310.2
Mains Power Connector, 1A, 250VAC, Male, Solder Terminal, ROHS COMPLIANT
SCHURTER
DF12.A026F150C0.2110.1
Mains Power Connector, 2A, 250VAC, Male, Solder Terminal, ROHS COMPLIANT
SCHURTER
DF12.A026F150C0.2310.2
Mains Power Connector, 2A, 250VAC, Male, Solder Terminal, ROHS COMPLIANT
SCHURTER
DF12.A026F150C0.3310.1
Mains Power Connector, 3A, 250VAC, Male, Solder Terminal, ROHS COMPLIANT
SCHURTER
DF12.A026F150C0.4310.2
Mains Power Connector, 4A, 250VAC, Male, Solder Terminal, ROHS COMPLIANT
SCHURTER
DF12.A026F150C0.5110.1
Mains Power Connector, 6A, 250VAC, Male, Solder Terminal, ROHS COMPLIANT
SCHURTER
DF12.A026F150C0.5310.1
Mains Power Connector, 6A, 250VAC, Male, Solder Terminal, ROHS COMPLIANT
SCHURTER
DF12.A026F150C0.5310.2
Mains Power Connector, 6A, 250VAC, Male, Solder Terminal, ROHS COMPLIANT
SCHURTER
DF12.A026F150C0.6110.1
Mains Power Connector, 8A, 250VAC, Male, Solder Terminal, ROHS COMPLIANT
SCHURTER
©2020 ICPDF网 联系我们和版权申明