EF11.A146F200U4.0014.01 [SCHURTER]
Mains Power Connector, 20A, 125/250VAC, Male;型号: | EF11.A146F200U4.0014.01 |
厂家: | SCHURTER INC. |
描述: | Mains Power Connector, 20A, 125/250VAC, Male |
文件: | 总4页 (文件大小:673K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
POWER ENTRY MODULES
EF11
Power entry module for high current
Type EF11
– Panel mount: – screw-on version, front or rear-side
– snap-in version, front-side
– Appliance inlet with circuit breaker type TA 45
– Version with line filter/shield see page 133
50
75
100
Characteristics
•
Circuit breaker 2-pole, rocker actuated, non-illuminated or
illuminated
•
•
•
Combined with thermal overload protection
Optional with undervoltage release or remote trip release
All single elements wired
Unwired versions available on request
Qualified for use in equipment according to IEC/EN 60950
•
Technical data
Rated voltage
125/250 VAC
n
Rated current I
10 up to 16 A; VDE
10 up to 20 A; UL, CSA, see table 1
> 1,5 kV between L-N
> 3 kV between L/N-PE
Dielectric strength
(50 Hz, 1 Min.)
Allowable ambient air
a
temperatures T
–10 °C to +55 °C
Degree of protection (front side) IP40 acc. to IEC 60529
Protection class
suitable for equipment with prot. cl. I,
acc. to IEC 61140
Terminals
Panel thickness s
quick-connect 6,3 x 0,8 mm
screw-on: max. 8 mm
snap-in: 1,5/2/2,5 mm
Thermoplastic, black, UL94 V-0
Materials: Housing
Appliance-inlet
acc. to IEC/EN 60320-1/C20,
Protection class I,
pin-temperature 70 °C (cold condition)
acc. to IEC/EN 60934, UL 1077,
CSA 22.2 no 235
Circuit breaker
type TA45
2-pole rocker switch, illuminated or
non-illuminated
Optional with undervoltage-
or remote trip release
Short circuit capacity Icn:
n
n
at I < 3 A/240 VAC: 10 x I
n
at I ≥ 3 A/240 VAC: 300 A
Accessories see page 171
75
www.schurter.com
POWER ENTRY MODULES
EF11
Technical data (continued)
Circuit breaker
Tripping characteristics
Tripping characteristics
≥ 3… < 18 A
Tripping characteristics
I ≥ 18 A
n
I
< 3 A
I
n
n
[ min ] [ sec
10'000
]
[ min ] [ sec
10'000
]
[ min ] [ sec
10'000
]
Type
Rated current
TA45
<3
Type
Rated current
TA45
≥18
Type
Rated current
TA45
≥ 3 A...
I
n
A
I
n
A
I
n
< 18 A
60
60
60
1
pole protected
1
pole protected
1
pole protected
2`000
30
2`000
30
2`000
30
2
pole protected
2
pole protected
2
pole protected
20
20
20
1`000
1`000
1`000
Ambient temp.
Ambient temp.
Ambient temp.
+23 °C
+23 °C
+23 °C
10
10
10
500
500
500
5
5
5
200
200
200
100
100
100
1
1
1
50
50
50
20
10
5
20
10
5
20
10
5
2
1
2
1
2
1
0,5
0,5
0,5
0,3
0,2
0,3
0,2
0,3
0,2
0,1
0,1
0,1
1,05 1,32
2
3
4
5
8
10
1,05 1,32
2
3
4
5
8
10
1,05 1,32
2
3
4
5
8
[ x I
10
Multiple of rated current
Multiple of rated current
Multiple of rated current
[ x I
]
[ x I
]
]
n
n
n
Effect of ambient temperature
* Ambient temperature [°C]
Correction
factor
Example
Rated current at +23 °C
Ambient temperature
Correction factor
The unit is calibrated for an ambient tempe-
rature of +23 °C. To determine the rated
current for a lower or higher ambient tempe-
rature, use a correction factor from the table
on the right side:
6,0 A
+40 °C
1,08
–10
–5
0,89
0,91
0,92
1,00
1,03
1,08
1,16
0
+23
+30
+40
+55
Chosen rated current at
+40 °C ambient temperature
6 A x 1,08 = 6,5 A
*Temperature must be measured at the rear
of the breaker next to the terminals after
equipment operating temperature has been
reached.
Dimensions
Screw-on mounting
Panel cut-out
76.7**
ca.
+0.05
31.7 - 0.08
72
0.05
2.3
0.8
36
+0.05
- 0.10
32.2
10.6
41.7
26.55
0.05
4.8
Ø3.3
Ø 6.4
0.10
32.5
Mounting screw torque 0,5 Nm
see table 1
76
www.schurter.com
POWER ENTRY MODULES
EF11
Dimensions
Snap-in mounting
Panel cut-out
76.7**
ca.72
+0.05
-0.08
36
0.05
2.3
31.7
10.6
41.7
S
0,05
26.55
+0.05
+0.05
-0.10
32.2
-0.10
32.5
4.8
**
Version
TA45 with undervoltage release
Diagram
Line
Load
Order code for EF11 (order example)
Type
Order code TA45
(2-pole rocker-switch
without accessories)
EF11. A B T W F 1 5 0 C 0 .
00 10. 01
see table 1
Wiring :
1 = wired
Protection class :
0 = Class I, housing black
Panel mount:
0 = Screw-on version
2 = Snap-in version, s = 1,5 mm
3 = Snap-in version, s = 2,0 mm
4 = Snap-in version, s = 2,5 mm
Terminals
1 = Quick connect terminals
6,3 x 0,8 mm
00 = without line filter
Please note that Schurter will establish an internal new part number for logistical use in addition to the order
code. The format of this internal part number is, for example EF11.3103.0010.01
Other versions on request
•
unwired versions
77
www.schurter.com
POWER ENTRY MODULES
EF11
Table 1 Selection for type TA45
Order example
ABT
W
F
150
C0
•
•
•
Line switch
2-pole, rocker actuated
Quick connect terminal
a
Other types on request
P1
Diagram
Thermal overload protection
without
with
with
1-pole
2-pole
P2
P1
P2
P1
P2
P1
3
4
3
5
6
6
Without illumination
ABC
ABT
ABD
A02
A04
A12
A14
A32
A34
With illumination
220…240 V
110…120 V
}
Colours
Switch front
Rocker
W
B
6
black
black
black
white
black
–
–
–
orange transp.
Rocker legend
Surface
Illustration Colour of print
Surface
Illustration Colour of print
F
embossed
printed
M
P
printed
printed
printed
black
I
I
O
O
H
K
L
white
black
white
white
black
printed
R
printed
Rated current :
• Without thermal overload protection: code C00
Position of the rocker legend
e.g F
I
= 16 A
}
n
• With thermal overload protection: rated current I (A)
n
I
Code
I
Code
I
Code
I
Code
n
n
n
n
19,0
20,0
190
200
10,0
11,0
12,0
100
110
120
16,0
17,0
18,0
160
170
180
13,0
14,0
15,0
130
140
150
Without release: code C0
Undervoltage release
Remote trip release
P2
P1
P2
P1
c
P2
P1
P2
P1
a
b
b
U<
U<
U<
Rated voltage U
n
U
E
Z
A
Code
2
3
4
240 V AC
230 V AC
120 V AC
•
•
•
•
•
•
•
•
•
•
•
•
78
www.schurter.com
相关型号:
EF11.A146FC00C0.0010.01
Mains Power Connector, 20A, 125/250VAC, Male, Solder Terminal, ROHS COMPLIANT
SCHURTER
EF11.A146FC00C0.0012.01
Mains Power Connector, 20A, 125/250VAC, Male, Solder Terminal, ROHS COMPLIANT
SCHURTER
EF11.A146FC00C0.0013.01
Mains Power Connector, 20A, 125/250VAC, Male, Solder Terminal, ROHS COMPLIANT
SCHURTER
EF11.A146FC00C0.0014.01
Mains Power Connector, 20A, 125/250VAC, Male, Solder Terminal, ROHS COMPLIANT
SCHURTER
©2020 ICPDF网 联系我们和版权申明