EF12.0572.1110.01 [SCHURTER]

Mains Power Connector, 20A, 125VAC, Male, Quick Connect Terminal, ROHS COMPLIANT;
EF12.0572.1110.01
型号: EF12.0572.1110.01
厂家: SCHURTER INC.    SCHURTER INC.
描述:

Mains Power Connector, 20A, 125VAC, Male, Quick Connect Terminal, ROHS COMPLIANT

连接器 电源连接器
文件: 总7页 (文件大小:613K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Power Entry Modules with Line Filter  
EF12  
https://www.schurter.com /PG06  
IEC Appliance Inlet C20 with Filter, Circuit Breaker TA45 (recessed)  
C20  
Approvals and Compliances  
70° C  
Description  
Characteristics  
- Panel Mount :  
- All single elements are already wired  
- Circuit Breaker non-illuminated or illuminated  
- With EMC-shield  
Screw-on mounting from front side  
- 3 Functions :  
Appliance Inlet Protection class I , circuit breaker type TA45 2-pole  
, Line filter in standard and medical version  
- Quick connect terminals 6.3 x 0.8 mm  
- Suitable for use in equipment according to IEC/UL 60950  
Suitable for use in medical equipment according to IEC/UL 60601-1  
Other versions on request  
- Variant with notch for V-Lock mating Cordsets  
References  
Alternative: version without line filter EF11  
Alternative: Standard version  
Weblinks  
pdf datasheet, html-datasheet, General Product Information, Distributor-  
Stock-Check, Accessories, Detailed request for product, Microsite  
Technical Data  
Ratings IEC  
Ratings UL/CSA  
Leakage Current  
12 - 16A @ Ta 40 °C / 250VAC; 50Hz  
12 - 20A @ Ta 40 °C / 250VAC; 60Hz  
standard < 0.5mA (250V / 60Hz)  
medical < 5 µA (250 V / 60 Hz)  
> 1.7kVDC between L-N  
> 2.7kVDC between L/N-PE  
Test voltage (2sec)  
-10°C to 55°C  
appliance inlet/-outlet  
Circuit Breakers  
C20 acc. to IEC 60320-1,  
UL 498, CSA C22.2 no. 42 (for cold  
conditions) pin-temperature 70 °C, 16A,  
Protection Class I  
Acc. IEC/EN 60934, UL 1077, CSA  
22.2 no. 235  
2-pole rocker switch, illuminated or non-  
illuminated. Optional with undervoltage-  
or remote trip release  
Short circuit capacity Icn:  
at In < 3A/240VAC : 10 x In  
at In 3A/240VAC : 300A  
Standard and Medical Version, IEC  
60939, UL 1283, CSA C22.2 no. 8  
Technical Details  
Dielectric Strength  
Allowable Operation Tempe-  
rature  
Climatic Category  
IP-Protection  
10/055/21 acc. to IEC 60068-1  
from front side IP 40 acc. to IEC 60529  
Suitable for appliances with protection  
class I acc. to IEC 61140  
Quick connect terminals 6.3 x 0.8 mm  
Screw: max 8mm  
Protection Class  
Line Filter  
MTBF  
Terminal  
Panel Thickness S  
> 100'000h acc. to MIL-HB-217 F  
Mounting screw torque max 0.5Nm  
Material: Housing  
Thermoplastic, black, UL 94V-0  
Approvals and Compliances  
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about  
Approvals  
Approvals  
The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.  
Approval Reference Type: EF12  
Approval Logo  
Certificates  
Certification Body  
Description  
VDE Approvals  
VDE  
Certificate Number: 40001520  
UL Approvals  
UL  
UL File Number: E72928  
1
EMC Products  
 
Power Entry Modules with Line Filter  
EF12  
https://www.schurter.com /PG06  
Product standards  
Product standards that are referenced  
Organization  
Design  
Standard  
Description  
Designed according to  
IEC 60320-1  
Appliance couplers for household and similar general purposes  
Passive filters for suppressing electromagnetic interference  
Switches for appliances. Part 1. General requirements  
Standard for Attachment Plugs and Receptacles  
Designed according to  
Designed according to  
Designed according to  
Designed according to  
Designed according to  
Designed according to  
IEC 60939  
IEC 61058-1  
UL 498  
UL 1283  
Electromagnetic interference filters  
CSA C22.2 no. 42  
CSA C22.2 no. 8  
General Use Receptacles, Attachment Plugs, and Similar Wiring Devices  
Electromagnetic interference (EMI) filters  
Application standards  
Application standards where the product can be used  
Organization  
Design  
Standard  
Description  
Designed for applications acc.  
IEC/UL 60950  
IEC 60950-1 includes the basic requirements for the safety of information  
technologyequipment.  
Designed for applications acc.  
IEC 60601-1  
Medical electrical equipment - Part 1: General requirements for basic  
safety and essential performance  
Compliances  
The product complies with following Guide Lines  
Identification  
Details  
Initiator  
Description  
CE declaration of conformity  
SCHURTER AG  
The CE marking declares that the product complies with the applicable  
requirements laid down in the harmonisation of Community legislation on  
its affixing in accordance with EU Regulation 765/2008.  
RoHS  
SCHURTER AG  
SCHURTER AG  
SCHURTER AG  
EU Directive RoHS 2011/65/EU  
China RoHS  
REACH  
The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March  
2007. It is similar to the EU directive RoHS.  
On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration,  
Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as  
"REACH") entered into force.  
MicrositeV-Lock  
SCHURTER AG  
SCHURTER AG  
V-Lock system are based on a matching plug-dose combination. The  
connector is equipped with a notch intended for use with the latching  
cordset. The cord latching system prevents against accidental removal of  
the cordset.  
Medical Equipment  
Suitable for use in medical equipment according to IEC/UL 60601-1  
2
EMC Products  
Power Entry Modules with Line Filter  
EF12  
https://www.schurter.com /PG06  
Dimension [mm]  
37  
76.2  
2.8  
0.8  
32.2  
10.6  
41.2  
32.9  
ø3.6/M3  
0.10  
9.5  
59.5  
ø3.3  
ø6.4  
5.3  
33.9  
* --- Version TA45 with undervoltage release  
Technical Data of Filter-Components  
Rated Current  
[A]  
Filter-Type  
Inductances Capacitance Capacitance  
R [M]  
L [mH]  
CX [nF]  
CY [nF]  
12  
16  
20  
12  
16  
20  
Standard Version  
2 x 0.8  
2 x 0.6  
2 x 0.3  
2 x 0.8  
2 x 0.6  
2 x 0.3  
100  
100  
100  
100  
100  
100  
2.2  
2.2  
2.2  
-
1
1
1
1
1
1
Standard Version  
Standard Version  
Medical Version (M5)  
Medical Version (M5)  
Medical Version (M5)  
-
-
Diagrams  
Standard version  
Medical version (M5)  
L’  
P1  
P2  
L’  
P1  
P2  
L
1)  
PE  
L
1)  
PE  
L1  
L1  
L2  
2)  
2)  
Cy  
Cy  
R
PE’  
PE’  
N’  
R
Cx  
Cx  
L2  
N’  
N
N
1) Line  
2) Load  
1) Line  
2) Load  
3
EMC Products  
Power Entry Modules with Line Filter  
EF12  
https://www.schurter.com /PG06  
- - - - 50differential mode _____ 50common mode  
Attenuation Loss  
Standard version  
12 A  
16 A  
20 A  
Medical version (M5)  
12 A  
16 A  
20 A  
4
EMC Products  
Power Entry Modules with Line Filter  
EF12  
https://www.schurter.com /PG06  
Table 1 Selection for type TA45  
Order example  
ABT  
W
F
150  
C0  
Circuit Breaker of Equipment  
2-pole, rocker actuated  
Quick connect terminal  
Other variants on request  
a
1
P
Diagram  
1-pole  
2-pole  
Thermal overload protection  
P2  
P1  
P2  
P1  
3
4
3
6
Without illumination  
ABT  
ABD  
A12  
A14  
A32  
A34  
With illumination  
220…240 V  
110…120 V  
}
Colours  
Switch front  
Rocker  
W
B
6
black  
black  
black  
white  
black  
orange transp.  
Rocker legend  
Surface  
Illustration Colour of print  
Surface  
Illustration Colour of print  
F
embossed  
printed  
M
P
printed  
printed  
printed  
black  
I
I
O
O
H
K
L
white  
black  
white  
white  
black  
printed  
R
printed  
Position of the rocker legend  
e.g F  
Rated current circuit breaker of equipment  
Code  
I
Code  
I
I
Code  
I
Code  
n
n
n
n
19,0 190  
20,0 200  
10,0 100  
11,0 110  
12,0 120  
16,0 160  
17,0 170  
18,0 180  
13,0 130  
14,0 140  
15,0 150  
Other rated currents on request  
Without release: code C0  
Undervoltage release  
Remote trip release  
P2  
P1  
P2  
P1  
P2  
P1  
c
P2  
P1  
b a  
b
U<  
U<  
U<  
Rated  
voltage U  
U
E
Z
A
Code  
n
2
3
4
240 V AC  
230 V AC  
120 V AC  
5
EMC Products  
Power Entry Modules with Line Filter  
EF12  
https://www.schurter.com /PG06  
Technical data (continued)  
Circuit breaker  
Tripping characteristics  
In < 3 A  
Tripping characteristics  
In > 3… < 18 A  
Tripping characteristics  
In >18 A  
[ min ] [ sec ]  
10'000  
[ min ] [ sec ]  
10'000  
[ min ] [ sec ]  
10'000  
Type  
TA45  
<3 A  
Type  
Rated current  
TA45  
> 3 A... < 18 A  
Type  
TA45  
Rated current  
I
n
I
>
I 18 A  
n
n
Rated current  
60  
60  
60  
1 pole protected  
1 pole protected  
1 pole protected  
2`000  
1`000  
500  
2`000  
30  
2`000  
1`000  
500  
30  
20  
30  
20  
2 pole protected  
2 pole protected  
2 pole protected  
20  
1`000  
+23 °C  
Ambient temp.  
+23 °C  
Ambient temp.  
10  
Ambient temp.  
+23 °C  
10  
5
10  
5
500  
5
200  
100  
50  
200  
200  
100  
50  
100  
1
1
1
50  
20  
10  
5
20  
10  
5
20  
10  
5
2
1
2
1
2
1
0,5  
0,5  
0,5  
0,3  
0,2  
0,3  
0,2  
0,3  
0,2  
0,1  
0,1  
0,1  
1,05 1,32  
2
3
4
5
8
10  
]
1,05 1,32  
2
3
4
5
8
10  
]
1,05 1,32  
2
3
4
5
8
[ x I  
10  
[ x I  
[ x I  
n
n
]
n
Multiple of rated current  
Multiple of rated current  
Multiple of rated current  
1)  
Effect of ambient temperature  
* Temperature must be measured at the rear of the breaker next  
to the terminals after equipment operating temperature has been  
reached.  
The unit is calibrated for an ambient temperature of +23 °C. To de-  
termine the rated current for a lower or higher ambient temperature,  
use a correction factor from the table on the right side:  
1)  
Example  
Rated current at +23 °C  
Ambient temperature  
Correction factor  
Chosen rated current at  
+40 °C ambient temperature  
6,0 A  
+40 °C  
1,08  
* Ambient temperature [°C]  
–10  
–5  
Correction factor  
0,89  
0,91  
0,92  
1,00  
1,03  
1,08  
1,16  
0
6 A x 1,08 = 6,5 A  
+23  
+30  
+40  
+55  
Configuration code (example)  
Order code TA45  
Color  
0 black  
Type  
(2-pole rocker-switch  
without accessories)  
Interlocking  
0 without V-Lock  
1 with V-Lock  
EF12 - ABTWF150C0 - 000 - 1111 - 00 - 00  
see table 1  
Terminal PE  
1 QC 6.3x0.8  
Terminal L and N  
1 QC 6.3x0.8, without connection to TA45  
3 Connection to TA45 non insulated  
Type of mains filter / capacitor / bleed resistor  
1 standard  
X2,Y2  
with bleed resistor  
2 medical M5  
X2  
with bleed resistor  
Rated current  
1)  
1
2
3
20 A  
16 A  
12 A  
1) The rated current of the line-filter must be equal  
or more than the rated current of TA45.  
6
EMC Products  
Power Entry Modules with Line Filter  
EF12  
https://www.schurter.com /PG06  
16 Pcs  
Packaging unit  
Accessories  
Description  
Cord retaining kits  
Cord retaining strain relief  
Flat head, H  
4700.0008  
Mating Outlets/Connectors  
Category / Description  
Connector Overview complete  
IEC Connector C19, Rewireable, Straight  
IEC Connector C19, Rewireable, Angled  
IEC Connector C19, Rewireable, Straight  
Connector further types to EF12  
4795  
4790  
0104U  
Mating Outlets/Connectors shuttered  
Power Cord Overview complete  
Overview Power Cord with IEC Appliance Connector C19, V-Lock, straight  
Power Cord further types to EF12  
VAC19KS  
The specifications, descriptions and illustrations indicated in this document are based on current  
information. All content is subject to modifications and amendments. Information furnished is believed  
to be accurate and reliable. However, users should independently evaluate the suitability and test each  
product selected for their own applications.  
7
EMC Products  

相关型号:

EF12.0699.2110.01

IEC Appliance Inlet C20 with Filter, Circuit Breaker TA45 (recessed)
SCHURTER

EF12.0885.2110.01

IEC Appliance Inlet C20 with Filter, Circuit Breaker TA45 (recessed)
SCHURTER

EF12.1089.1110.01

IEC Appliance Inlet C20 with Filter, Circuit Breaker TA45 (recessed)
SCHURTER

EF12.2105.2110.01

IEC Appliance Inlet C20 with Filter, Circuit Breaker TA45 (recessed)
SCHURTER

EF12.3103.2110.01

IEC Appliance Inlet C20 with Filter, Circuit Breaker TA45 (recessed)
SCHURTER
FERYSTER
FERYSTER

EF12.6-K-H-6P-SS

COIL FORMER
FERYSTER
FERYSTER

EF12.6-K-H-8P-SS

COIL FORMER
FERYSTER
FERYSTER

EF12.A026F150C0.1110.01

Mains Power Connector, 20A, 125VAC, Male, Solder Terminal, ROHS COMPLIANT
SCHURTER