F2.A046FC00U4.2210.01 [SCHURTER]
Mains Power Connector, 16A, 125/250VAC, Male;型号: | F2.A046FC00U4.2210.01 |
厂家: | SCHURTER INC. |
描述: | Mains Power Connector, 16A, 125/250VAC, Male 连接器 电源连接器 |
文件: | 总5页 (文件大小:2904K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
New compact
Power Entry Module EF12
Consisting of appliance inlet, circuit breaker
for equipment and line-filter.
Now for high currents
• 12/16 A IEC/EN
• 12/16/20 A UL/CSA
EF12 supplements type EF11
launched December 2001.
Certified Management Systems
European
Foundation
for
Quality
Management
«General Member of»
POWER ENTRY MODULE / GERÄTESTECKER-KOMBIELEMENT
EF12
Power entry module with line-filter, for high
current, Type EF12
– Panel mount: – screw-on version, front-side
– Appliance inlet, circuit breaker type TA 45, line-filter,
standard and medical versions
C
US
Characteristics
•
Circuit breaker, 2-pole, rocker actuated, non-illuminated. llluminated
version on request.
•
•
•
•
•
Combined with thermal overload protection
Optional with undervoltage release or remote trip release
All single elements wired
With EMC-shield
Qualified for use in equipment according to IEC/EN 60950
Technical data
Rated voltage
Rated currents I
125/250 VAC; 50/60 Hz
1)
n
a
Filter
12/16 A
@ T 40 °C; VDE
a
12/16/20 A @ T 40 °C; UL/CSA
10 up to 16 A; VDE, see table 1
10 up to 20 A; UL/CSA, see table 1
< 0,5 mA (250 V/60Hz)
TA 45
Leackage current, Standard
Medical
< 5 µA (250 V/60Hz)
Test voltage (2 sec)
1,7 kVDC between L-N
2,7 kVDC between L/N-PE
Allowable ambient air
a
temperatures T
–10 °C to +55 °C
Climatic category
10/055/21 acc.to IEC/EN 60068-1
Degree of protection (front side) IP40 acc. to IEC 60529
Protection class
suitable for equipment with prot. cl. I,
acc. to IEC 61140
Terminals
Panel thickness s
quick-connect 6,3 x 0,8 mm
s = max. 8 mm
Materials: Housing, plastic part Thermoplastic, black, UL94 V-0
Appliance-inlet
acc. to IEC/EN 60320-1/C20,
Protection class I,
pin-temperature 70 °C (cold condition)
acc. to IEC/EN 60934, UL 1077,
CSA 22.2 no 235
Circuit breaker
type TA 45
2-pole rocker switch,
non-illuminated.
Optional with undervoltage-
or remote trip release
Short circuit capacity Icn:
n
n
at I < 3 A/240 VAC: 10 x I
n
at I ≥ 3 A/240 VAC: 300 A
Line filter,
standard and medical
acc.to IEC 60939/EN 133200/
UL 1283/CSA C22.2 no 8
1)
Application note
The rated current of the line-filter must be equal or higher than the
rated current of the circuit-breaker.
www.schurter.com
POWER ENTRY MODULE / GERÄTESTECKER-KOMBIELEMENT
EF12
Technical data (continued)
Circuit breaker
Tripping characteristics /
< 3 A
Tripping characteristics /
≥ 3… < 18 A
Tripping characteristics /
I ≥ 18 A
n
I
I
n
n
[ min ] [ sec
10'000
]
[ min ] [ sec
10'000
]
[ min ] [ sec
10'000
]
Type
Rated current
Nennstrom
/
Typ
TA45
<3
Type
Rated current
Nennstrom
/
Typ
TA45
≥18
Type
Rated current
Nennstrom
/
Typ
TA45
I
n
A
I
n
A
3
1
A ≥ I <18 A
n
pole protected
60
60
60
1
pole protected
1polig geschützt
pole protected
1
pole protected
1polig geschützt
2 pole protected
1polig geschützt
pole protected
2`000
30
2`000
30
2`000
30
2
2
2polig geschützt
2polig geschützt
2polig geschützt
20
20
20
1`000
1`000
1`000
Ambient temp.
Ambient temp.
Ambient temp.
Umgebungstemp.
+23 °C
Umgebungstemp.
+23 °C
Umgebungstemp.
+23 °C
10
10
10
500
500
500
5
5
5
200
200
200
100
100
100
1
1
1
50
50
50
20
10
5
20
10
5
20
10
5
2
1
2
1
2
1
0,5
0,5
0,5
0,3
0,2
0,3
0,2
0,3
0,2
0,1
0,1
0,1
1,05 1,32
2
3
4
5
8
10
1,05 1,32
2
3
4
5
8
10
1,05 1,32
2
3
4
5
8
10
Multiple of rated current
Multiple of rated current
Multiple of rated current
[ x I
n
]
[ x I
n
]
[ x I ]
n
Effect of ambient temperature
* Ambient temperature [°C] / Correction
Example
Rated current at +23 °C
Nennstrom bei +23 °C
* Umgebungs-
factor /
The unit is calibrated for an ambient tempe-
rature of +23 °C. To determine the rated
current for a lower or higher ambient tempe-
rature, use a correction factor from the table
on the right side:
6,0 A
+40 °C
1,08
Ambient temperature
Umgebungstemperatur
–10
–5
0,89
0,91
0,92
1,00
1,03
1,08
1,16
Correction factor
Korrekturfaktor
0
+23
+30
+40
+55
Chosen rated current at
+40 °C ambient temperature
6 A x 1,08 = 6,5 A
* Temperature must be measured at the rear
of the breaker next to the terminals after
equipment operating temperature has been
reached.
Dimensions
Screw-on mounting
Panel cut-out
76,2*
±0.15
37
10.6
41.2
2.8
+0.05
-0.10
32.2
0.8
32.9
s
±0.05
Ø 3.3
9.5
59.5
5.3
±0.10
33.9
Ø 6.4
Mounting screw torque 0,5 Nm
Version TA45 with undervoltage release
*
www.schurter.com
POWER ENTRY MODULE / GERÄTESTECKER-KOMBIELEMENT
EF12
Derating curve
Diagram
Correlation between max. operating current I and the ambient air
Line-switch non-illuminated
a
temperature T
Standard version
Medical version
Ambient air temperature T
Umgebungstemperatur T
a
ºC /
in °C
u
Technical data of filters-components
Rated current / Filter-Type / Inductance / Induktivitäten
Capacitance / Kapazitäten
R
DC-Resistance
Nennstrom (A)
Filter-Typ
L 1/L2 (mH)
CX (nF)
CY (nF)
(MΩ) @ 25 °C (mΩ)
12
16
20
12
16
20
2 x 0,8
7,5
5
3,5
7,5
5
Standard
100
2 x 2,2
1
2 x 0,6
2 x 0,3
2 x 0,8
2 x 0,6
2 x 0,3
Medical
100
1
3,5
Attenuation loss line-filter / Einfügungsdämpfung Netzfilter
12 A
Standard version /
16 A
20 A
Standardversion
12 A
16 A
20 A
Medical version
Order code for EF12 (order example)
Line filter, rated current, 1 = 20 A, 2 = 16 A, 3 = 12 A
Line filter version, 1 = standard, 2 = medical
Terminals 1 = Quick connect terminals 6,3 x 0,8 mm
Panel mount: 0 = Screw-on version
Type / Order code TA45 /
(2-pole rocker-switch
without accessories) /
Protection class: 0 = Class I, housing black
Wiring: 1 = wired
F 2 . A B T W F 1 5 0 C 0 .
11 10. 0 1
see table 1
Please note that Schurter will establish an internal new part number for logistical use in addition to the order code. For example, order code F2ABTWF200C0111
will reflect the internal part number of EF12.0035.1110.01.
Application note
The rated current of the line-filter must be equal or less than the rated current of the circuit-breaker
Other versions on request
•
Rocker switch illuminated
www.schurter.com
POWER ENTRY MODULE / GERÄTESTECKER-KOMBIELEMENT
EF12
Table 1
Selection for type TA45
Order example
ABT
W
F
150
C0
• Line-switch
• 2-pole, rocker actuated
• Quick connect terminal
a
P1
Other types on request
Diagram
P2
P1
P2
P1
P2
P1
3
4
3
5
6
6
Without illumination
With illumination / 220…240 V
ABC
ABT
ABD
A02
A04
A12
A14
A32
A34
Mit Beleuchtung
110…120 V
}
Colours
Switch front /
Rocker
W
B
6
black / schwarz
black / schwarz
black / schwarz
white / weiss
black / schwarz
–
–
–
orange transp.
Rocker legend
Surface /
Illustration / Colour of print /
Surface /
Illustration / Colour of print
O
O
F
embossed
M
P
printed / bedruckt
black
I
I
O
O
H
K
L
printed / bedruckt
printed / bedruckt
printed / bedruckt
white
black
printed / bedruckt
printed / bedruckt
white
black
R
O
white
Position of the rocker legend
e. g F
• Without thermal overload protection: code C00
I
= 16 A
n
• With thermal overload protection: rated current I (A)
n
I
Code
I
Code
I
Code
I
Code
n
n
n
n
19,0
20,0
190
200
10,0
11,0
12,0
100
110
120
16,0
17,0
18,0
160
170
180
13,0
14,0
15,0
130
140
150
Without release: code C0
Undervoltage release
Remote trip release
P2
P1
P2
P1
c
P2
P1
P2
P1
a
b
b
U<
U<
U<
Rated voltage U
n
U
E
Z
A
Code
2
3
4
240 V AC
230 V AC
120 V AC
•
•
•
•
•
•
•
•
•
•
•
•
www.schurter.com
相关型号:
©2020 ICPDF网 联系我们和版权申明