KD13.1101.109 [SCHURTER]
IEC Appliance Inlet C14 with Fuseholder 1- or 2-pole, Line Switch 1- or 2-pole and Voltage Selector; IEC设备入口C14与保险丝座1或2杆,线路开关1或2极和电压选择型号: | KD13.1101.109 |
厂家: | SCHURTER INC. |
描述: | IEC Appliance Inlet C14 with Fuseholder 1- or 2-pole, Line Switch 1- or 2-pole and Voltage Selector |
文件: | 总4页 (文件大小:558K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Power entry modules without line filter
KD
www.schurter.com/pg05
IEC Appliance Inlet C14 with Fuseholder 1- or 2-pole, Line Switch 1- or 2-pole and Voltage Selector
Standard or Medical Fuse drawer
C14
70° C
Description
-ꢀPanelꢀMount:
Characteristics
-ꢀAllꢀsingleꢀelementsꢀareꢀalreadyꢀwired
-ꢀTheꢀfuseꢀdrawerꢀ"Fingergrip"ꢀcanꢀbeꢀremovedꢀbyꢀhand
ꢀ Forꢀaddedꢀsafetyꢀ"Extra-Safe"ꢀfuseꢀdrawersꢀareꢀavailable
ꢀ Screw-onꢀversionꢀfromꢀfrontꢀorꢀrearꢀside,ꢀsnap-inꢀversionꢀfromꢀfrontꢀ
sideꢀ
ꢀ FuseꢀdrawerꢀmeetsꢀrequirementsꢀofꢀmedicalꢀstandardꢀIEC/ENꢀ60601-1
ꢀ Theꢀfuseꢀdrawerꢀcanꢀonlyꢀbeꢀopenedꢀwithꢀtheꢀaidꢀofꢀaꢀtool
ꢀ Theꢀfuseholderꢀisꢀaccessibleꢀfromꢀtheꢀequipmentꢀfront
-ꢀ4ꢀFunctions:
ꢀ ApplianceꢀInletꢀProtectionꢀclassꢀI,ꢀLineꢀSwitchꢀ1-ꢀorꢀ2-pole,ꢀFusehol-
derꢀwithꢀinterchangeableꢀfuseꢀdrawerꢀforꢀFuse-linksꢀ5ꢀxꢀ20ꢀmmꢀorꢀ
6.3ꢀxꢀ32ꢀmm,ꢀwithꢀorꢀwithoutꢀvoltageꢀselectorꢀ(step)ꢀ
-ꢀQuickꢀconnectꢀterminalsꢀ4.8ꢀxꢀ0.8ꢀmmꢀ
-ꢀAlternative:ꢀversionꢀwithꢀlineꢀfilterꢀꢀCDꢀ
-ꢀQualifiedꢀforꢀuseꢀinꢀequipmentꢀaccordingꢀIEC/ENꢀ60950
Other versions on request
-ꢀLineꢀswitch,ꢀilluminatedꢀꢀ
-ꢀLineꢀswitchꢀwithꢀotherꢀrockerꢀmarking
-ꢀLineꢀswitchꢀ1-pole
Approvals
-ꢀVDEꢀLicenseꢀNumber:ꢀ40011925
-ꢀULꢀLicenseꢀNumber:ꢀE93617
-ꢀCSAꢀLicenseꢀNumber:ꢀ38456
-ꢀForꢀprotectionꢀclassꢀII
References
GeneralꢀProductꢀInformation
Weblinks
Approvals,ꢀRoHS,ꢀCHINA-RoHS,ꢀMatingꢀConnectors,ꢀe-Store,ꢀ
Distributor-Stock-Check,ꢀAccessories
Technical Data
RatingsꢀIEC
RatingsꢀUL/CSA
DielectricꢀStrength
10ꢀAꢀ/ꢀ250ꢀVAC;ꢀ50ꢀHz
10ꢀAꢀ/ꢀ125ꢀVAC;ꢀ60ꢀHz
>ꢀ3ꢀkVACꢀbetweenꢀL-Nꢀ
>ꢀ4ꢀkVACꢀbetweenꢀL/N-PEꢀ
(1ꢀmin/50ꢀHz)
ApplianceꢀInlet
Fuseholder
C14ꢀacc.ꢀtoꢀIEC/ENꢀ60320-1,ꢀ
ULꢀ498,ꢀCSAꢀC22.2ꢀno.ꢀ42ꢀ(forꢀcoldꢀ
conditions)ꢀpin-temperatureꢀ70ꢀ°C,ꢀ10ꢀA,ꢀ
ProtectionꢀClassꢀ1
1ꢀorꢀ2ꢀpole,ꢀShocksafeꢀcategoryꢀPC2ꢀ
acc.ꢀtoꢀIECꢀ60127-6,ꢀ
AllowableꢀOperationꢀTemp.
DegreeꢀofꢀProtection
ProtectionꢀClass
-25ꢀ°Cꢀtoꢀ70ꢀ°C
forꢀfuse-linksꢀ5ꢀxꢀ20ꢀorꢀ6.3ꢀxꢀ32ꢀmm
fromꢀfrontꢀsideꢀIPꢀ40ꢀacc.ꢀtoꢀIECꢀ60529
Suitableꢀforꢀappliancesꢀwithꢀprotectionꢀ
classꢀ1ꢀacc.ꢀtoꢀIECꢀ61140
Quickꢀconnectꢀterminalsꢀ4.8ꢀxꢀ0.8ꢀmmꢀ
,ꢀtin-plated
Screw:ꢀmaxꢀ8ꢀmmꢀ
Mountingꢀscrewꢀtorqueꢀmaxꢀ0.5ꢀNmꢀ
Snap-in:ꢀ1.5/2/2.5ꢀmm
RatedꢀPowerꢀAcceptanceꢀ@ꢀ 5ꢀxꢀ20:ꢀ2.5ꢀWꢀ(1ꢀpole)/ꢀ2ꢀWꢀ(2-pole)ꢀperꢀ
Taꢀ23ꢀ°C
poleꢀ
6.3ꢀxꢀ32:ꢀ3.15ꢀWꢀ(1ꢀpole)/ꢀ2.5ꢀWꢀ(2-pole)ꢀ
perꢀpole
Admissibleꢀpowerꢀacceptanceꢀatꢀhig-
herꢀambientꢀtemperatureꢀseeꢀderatingꢀ
curves
Terminal
PowerꢀAcceptanceꢀ@ꢀTaꢀ>ꢀ
23°C
PanelꢀThicknessꢀs
LineꢀSwitch
Rockerꢀswitchꢀ2-pole,ꢀnon-illuminated,ꢀ
acc.ꢀtoꢀIECꢀ61058-1ꢀ
Material:ꢀHousing
Thermoplastic,ꢀblack,ꢀULꢀ94V-0
Technicalꢀdetails
VoltageꢀSelectors
optional,ꢀstep,ꢀ2-4ꢀdigits
Connectors
ꢀ
Power entry modules without line filter
KD
www.schurter.com/pg05
Dimensions
ꢀ83.5ꢀmm
Screw on PCB mounting
Snap-in mounting
30
55
30
55
M3/ø 3.6
R 6
0.1
S
R 4.5
4.8x0.8
R 4.5
4.8x0.8
0
-0.2
0
-0.2
R 3
R 3
18
27.5
18
27.5
R 3.1
R 3.1
2
2.2
2
2.2
27.5+0.2
27.5+0.2
0
0
27.2
27.2
Diagrams
without voltage selector
without voltage selector
with voltage selector
with voltage selector
1-pole
2-pole
1-pole
Fuses
2-pole
Derating Curves
Fuses
5 x 20 mm (1-pole)
5 x 20 mm (2-pole, per pole)
2.5
2.0
2.0
1.5
1.0
0.5
1.5
I = 1.0 In
I = 0.7 In
I = << In
I = 1.0 In
I = 0.7 In
I = << In
1.0
0.5
0.0
0.0
0
20
40
60
80
100
0
20
40
60
80
100
Ambient air temperature Ta °C
Ambient air temperature Ta °C
Fuses
6.3 x 32 mm (1-pole)
Fuses
6.3 x 32 mm (2-pole, per pole)
3.15
2.5
2.0
2.5
2.0
I = 1.0 In
I = 1.0 In
I = 0.7 In
I = << In
1.5
1.0
0.5
0.0
I = 0.7 In
I = << In
1.5
1.0
0.5
0.0
0
20
40
60
80
100
0
20
40
60
80
100
Ambient air temperature Ta °C
Ambient air temperature Ta °C
Connectors
ꢁ
Power entry modules without line filter
KD
www.schurter.com/pg05
Fuseꢀdrawerꢀmustꢀbeꢀorderedꢀseparately
Type
Panel mounting
Panel Thickness
s [mm]
Fuseholder
Line Switch
Voltage selector max.
4 pos*
Order Number
KD
KD
KD
KD
KD
KD
KD
KD
KD
KD
KD
KD
KD
KD
KD
KD
Screw
Screw
-
-
1-pole
1-pole
2-pole
2-pole
1-pole
1-pole
1-pole
1-pole
1-pole
1-pole
2-pole
2-pole
2-pole
2-pole
2-pole
2-pole
Rocker switch
Rocker switch
Rocker switch
Rocker switch
Rocker switch
Rocker switch
Rocker switch
Rocker switch
Rocker switch
Rocker switch
Rocker switch
Rocker switch
Rocker switch
Rocker switch
Rocker switch
Rocker switch
2-4 digits
without
KD13.4101.151
KD13.1101.151
KD14.4101.151
KD14.1101.151
KD13.4101.105
KD13.4101.107
KD13.4101.109
KD13.1101.105
KD13.1101.107
KD13.1101.109
KD14.4101.105
KD14.4101.107
KD14.4101.109
KD14.1101.105
KD14.1101.107
KD14.1101.109
Screw
-
2-4 digits
without
Screw
-
Snap-in
Snap-in
Snap-in
Snap-in
Snap-in
Snap-in
Snap-in
Snap-in
Snap-in
Snap-in
Snap-in
Snap-in
1.5
2
2-4 digits
2-4 digits
2-4 digits
without
2.5
1.5
2
without
2.5
1.5
2
without
2-4 digits
2-4 digits
2-4 digits
without
2.5
1.5
2
without
2.5
without
Canꢀbeꢀusedꢀasꢀ2-/3-positionꢀvoltageꢀselectorꢀ-ꢀtakeꢀonlyꢀcorrespondingꢀterminals
20ꢀPcsꢀ
Packaging unit
Required Accessory
Description
Fusedrawer 3
Fusedrawer for Fuse Links 5x20mm resp.. 6.3x32mm
Fingergrip, 5 x 20, 2-pole, Voltage Selectors
4303.2014.00
4303.2014.01
4303.2014.02
4303.2014.03
Fingergrip, 5 x 20, 2-pole, Voltage Selectors, 100, 120, 220, 240
Fingergrip, 5 x 20, 2-pole, Voltage Selectors, 110, 150, 220
Fingergrip, 5 x 20, 2-pole, Voltage Selectors, 110, 220
...
Accessories
Assorted Covers
Rear Cover
0859.0074
Cord retaining kits
Cord retaining strain relief
Flat head, A
4700.0001
Connectors
ꢂ
Power entry modules without line filter
KD
www.schurter.com/pg05
Mating Outlets/Connectors
Category / Description
Appliance Outlet Overview complete
IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder or Quick-connect Terminal
IEC Appliance Outlet F, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal
4787
4788
IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal
IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder or Quick-connect Terminal
5091
5092
Appliance Outlet further types to KD
Connector Overview complete
IEC Connector C15, Rewireable, Straight
IEC Connector C15A, Rewireable, Straight
IEC Connector C15A, Rewireable, Straight
IEC Connector C15A, Rewireable, Angled
IEC Connector C13, Rewireable, Angled
Connector further types to KD
0101
0102
0102-G
0112
4012
...
Power Cord Overview complete
Power Cord with IEC Connector C13, Angled
Power Cord with IEC Connector C13, Angled
Power Cord with IEC Connector C13, Angled
Power Cord with IEC Connector C13, Angled
Power Cord with IEC Connector C13
0311
3011
3012
3013
3020
...
Power Cord further types to KD
Theꢀspecifications,ꢀdescriptionsꢀandꢀillustrationsꢀindicatedꢀinꢀthisꢀdocumentꢀareꢀbasedꢀonꢀ
Connectors
currentꢀinformation.ꢀAllꢀcontentꢀisꢀsubjectꢀtoꢀmodificationsꢀandꢀamendments.
4
相关型号:
KD13.1101.151
IEC Appliance Inlet C14 with Fuseholder 1- or 2-pole, Line Switch 1- or 2-pole and Voltage Selector
SCHURTER
KD13.4101.105
IEC Appliance Inlet C14 with Fuseholder 1- or 2-pole, Line Switch 1- or 2-pole and Voltage Selector
SCHURTER
KD13.4101.107
IEC Appliance Inlet C14 with Fuseholder 1- or 2-pole, Line Switch 1- or 2-pole and Voltage Selector
SCHURTER
KD13.4101.109
IEC Appliance Inlet C14 with Fuseholder 1- or 2-pole, Line Switch 1- or 2-pole and Voltage Selector
SCHURTER
KD13.4101.151
IEC Appliance Inlet C14 with Fuseholder 1- or 2-pole, Line Switch 1- or 2-pole and Voltage Selector
SCHURTER
©2020 ICPDF网 联系我们和版权申明