T11-811_V02 [SCHURTER]

Schurter Inc. [SCHURTER]^768;
T11-811_V02
型号: T11-811_V02
厂家: SCHURTER INC.    SCHURTER INC.
描述:

Schurter Inc. [SCHURTER]^768

文件: 总6页 (文件大小:386K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Thermal (T- and TA-Line)  
T11-811  
https://www.schurter.com /PG17_20  
Circuit Breaker for Equipment thermal, Drop-in type, Reset type, Quick connect terminals  
See below:  
Approvals and Compliances  
Description  
- Drop-in type  
Applications  
- Power tools  
- Thermal circuit breaker  
- 1-pole  
- Reset type  
- Household Equipment  
- Power supplies and chargers  
- Industrial appliances  
- Quick connect terminals 6.3 x 0.8 mm  
Weblinks  
pdf data sheet, html datasheet, General Product Information, Distributor-  
Stock-Check, Detailed request for product, Product News  
Unique Selling Proposition  
- Compact design  
- Positively trip-free release  
- Available with cover  
- Different mounting possibilities  
Technical Data  
Rated Voltage AC  
AC 240 VAC  
Overload  
IEC: min. 40trips  
@ 6 x Ir, cos φ 0.6  
UL / CSA: min. 50trips  
@ 1.5 x Ir, cos φ 0.75  
-5°C to 60°C  
1.5 mm @ 10 - 60 Hz  
acc. to IEC 60068-2-6, test Fc  
5 G @ 60 - 500 Hz  
acc. to IEC 60068-2-6, test Fc  
100 G / 6ms  
acc. to IEC 60068-2-27, test Ea  
Thermal  
Reset type  
ca. 10g  
Rated Voltage DC  
Rated current range AC  
Conditional short circuit capa- IEC 60934: PC1, AC 240 V: 2 kA  
city Inc  
Short circuit capacity Icn  
48 VDC  
0.05 - 16 A  
Allowable Operation Temp.  
Vibration Resistance  
IEC 60934: at In < 6.5 A/240 VAC : 8  
x In  
IEC 60934: at In 6.5 A/240 VAC : 96  
A
front side IP40 acc. to IEC 60529  
50Hz: > 1.5kV  
Impulse 1.2/50 μs: > 2.5kV  
500VDC > 100 MΩ  
Shock Resistance  
Degree of Protection  
Dielectric Strength  
Tripping Type  
Actuation Type  
Weight  
Insulation Resistance  
Endurance typical  
2 x Ir: 500switching cycles  
Endurance minimum  
Reset type  
AC : 2 x Ir , cos φ 0.6 :  
DC : 2 x Ir , L/R = 2 - 3 ms :  
50switching cycles  
Approvals and Compliances  
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about  
Approvals  
SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national  
and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF  
16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agree-  
ments by SCHURTER.  
1
Circuit Breakers  
Thermal (T- and TA-Line)  
T11-811  
https://www.schurter.com /PG17_20  
Approvals  
The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.  
Approval Reference Type: T11  
Approval Logo  
Certificates  
Certification Body  
Description  
VDE Approvals  
VDE  
VDE Certificate Number: 99759  
UL Approvals  
UL  
UL File Number: E71572  
CCC Approvals  
CCC  
CCC Certificate Number: 2020970307003506  
Product standards  
Product standards that are referenced  
Organization  
Design  
Standard  
Description  
Designed according to  
IEC 60934  
Circuit-breakers for equipment (CBE)  
Designed according to  
Designed according to  
Designed according to  
UL 1077  
Standard for Supplementary Protectors for Use in Electrical Equipment  
Supplementary Protectors  
CSA C22.2 No. 235  
GB 17701  
Circuit-breaker for equipment  
Application standards  
Application standards where the product can be used  
Organization  
Design  
Standard  
Description  
Designed for applications acc.  
IEC/UL 62368-1  
Audio/video, information and communication technology equipment - Part  
1: Safety requirements  
Compliances  
The product complies with following Guide Lines  
Identification  
Details  
Initiator  
Description  
CE declaration of conformity  
SCHURTER AG  
The CE marking declares that the product complies with the applicable  
requirements laid down in the harmonisation of Community legislation on  
its affixing in accordance with EU Regulation 765/2008.  
UKCA declaration of conformity  
SCHURTER AG  
The UKCA marking declares that the product complies with the applicable  
requirements laid down in the British Amendment of Regulation (EC)  
765/2008.  
RoHS  
SCHURTER AG  
SCHURTER AG  
SCHURTER AG  
Directive RoHS 2011/65/EU, Amendment (EU) 2015/863  
China RoHS  
REACH  
The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March  
2007. It is similar to the EU directive RoHS.  
On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration,  
Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as  
"REACH") entered into force.  
2
Circuit Breakers  
Thermal (T- and TA-Line)  
T11-811  
https://www.schurter.com /PG17_20  
Dimension [mm]  
T11-811 <7,5A  
T11-811 >7,5 A  
T11-811N  
3
1
2
9
10  
Ø4  
11  
19  
15.2  
6.3  
Diagrams  
Rated current 7,5 A  
Rated current >7,5 A  
1
1
2
3
Shunt terminal T11-...N 6,5 A  
1
2
3
3
Circuit Breakers  
Thermal (T- and TA-Line)  
T11-811  
https://www.schurter.com /PG17_20  
Typical internal resistance per pole  
Rated Current [A]  
Internal Resistance []  
0.05  
380.000  
5.200  
1.350  
0.300  
0.130  
0.080  
0.040  
0.040  
0.020  
0.012  
0.012  
0.011  
0.0095  
0.0095  
0.0085  
0.0085  
0.0075  
0.0075  
0.50  
1.00  
2.00  
3.00  
4.00  
5.00  
6.00  
7.00  
8.00  
9.00  
10.00  
11.00  
12.00  
13.00  
14.00  
15.00  
16.00  
Effect of ambient temperature  
The units are calibrated for an ambient temperature of +23°C. To determine the rated cur-  
rent for a lower or higher ambient temperature, use a correction factor (typical value) from  
the table below:  
Ambient Temperature [°C]  
Correction factor  
-5  
0.87  
0.90  
0.95  
1.00  
1.04  
1.10  
1.15  
1.20  
0
+10  
+23  
+30  
+40  
+50  
+60  
Example: Rated current = 5 A, Environmental temperature = 40 °C, --> Correction factor =  
1.1, Resulting current = 5.5 A --> Fount to next higher rated current: 6 A  
4
Circuit Breakers  
Thermal (T- and TA-Line)  
T11-811  
https://www.schurter.com /PG17_20  
Time-Current-Curves  
[ min] [ sec]  
10`000  
< 6,5 A  
>
6,5 A  
60  
2`000  
30  
20  
1`000  
10  
500  
5
200  
100  
1
50  
20  
10  
5
2
1
0,5  
0,3  
0,2  
0,1  
1,05 1,35  
2
3
4
5
8
10  
Multiple of Rated Current In  
Reference Temperature +23°  
Config. Code  
T11|-|1|2|3|A|B|-|1.23|  
The characters are placeholders for the correspondingly keys of selections from the key tables.  
Rated current  
Configuration  
key  
T11|-|1|2|3|A|B|-|1.23|= Mounting  
Mounting  
Configuration  
key  
0.05 A  
0.05  
0.1  
0.15  
0.2  
0.3  
0.4  
0.5  
0.6  
0.7  
0.8  
0.9  
1
0.1 A  
Drop-in type  
8
0.15 A  
0.2 A  
T11|-|1|2|3|A|B|-|1.23|= Actuation Type  
0.3 A  
Actuation Type  
Configuration  
key  
0.4 A  
0.5 A  
Reset type  
1
0.6 A  
0.7 A  
T11|-|1|2|3|A|B|-|1.23|= Terminal  
0.8 A  
Terminal  
Configuration  
key  
0.9 A  
1.0  
Quick connect terminal 6.3x0.8mm  
T11|-|1|2|3|A|B|-|1.23|= Shunt terminal  
Shunt terminal  
1
1.1 A  
1.1  
1.2  
1.3  
1.4  
1.5  
1.6  
1.7  
1.8  
1.9  
2
1.2 A  
1.3 A  
Configuration  
key  
1.4 A  
1.5 A  
Shunt terminal  
N
1.6 A  
T11|-|1|2|3|A|B|-|1.23|= Setting indication  
1.7 A  
1.8 A  
Setting indication  
Configuration  
key  
1.9 A  
2.0 A  
Setting indication  
R
2.1 A  
2.1  
2.3  
T11|-|1|2|3|A|B|-|1.23|= Rated current  
2.3 A  
Other rated currents on request  
5
Circuit Breakers  
Thermal (T- and TA-Line)  
T11-811  
https://www.schurter.com /PG17_20  
Rated current  
Configuration  
key  
Rated current  
Configuration  
key  
2.5 A  
2.5  
2.8  
3
7.5 A  
7.5  
8
2.8 A  
8.0 A  
3.0 A  
8.5 A  
8.5  
9
3.3 A  
3.3  
3.5  
4
9.0 A  
3.5 A  
9.5 A  
9.5  
10  
11  
12  
13  
14  
15  
16  
4.0 A  
10.0 A  
4.5 A  
4.5  
5
11.0 A  
5.0 A  
12.0 A  
5.5 A  
5.5  
6
13.0 A  
6.0  
14.0 A  
6.5 A  
6.5  
7
15.0 A  
7.0 A  
16.0 A  
Other rated currents on request  
Other rated currents on request  
Variants  
Rated current  
Construction variants  
Shunt terminal Setting indication  
Config. Code  
Order Number  
3.0 A  
5.0 A  
5.5 A  
2.5 A  
6.0  
T11-811-3  
T11-811-5  
T11-811-5.5  
T11-811-2.5  
T11-811-6  
4400.0112  
4400.0114  
4400.0120  
4400.0178  
4400.0179  
Availability for all products can be searched real-time:https://www.schurter.com/en/Stock-Check/  
Stock-Check-SCHURTER  
100 Pcs  
Packaging Unit  
The specifications, descriptions and illustrations indicated in this document are based on current  
information. All content is subject to modifications and amendments. Information furnished is believed  
to be accurate and reliable. However, users should independently evaluate the suitability and test each  
product selected for their own applications.  
6
Circuit Breakers  

相关型号:

T11-814N-2.3-TZZ01

T11-814N-2.3-TZZ01
SCHURTER

T11-814NR-0.05

T11-814NR-0.05
SCHURTER

T11-814NR-0.15-TZZ01

T11-814NR-0.15-TZZ01
SCHURTER

T11-814NR-0.2

T11-814NR-0.2
SCHURTER

T11-814NR-0.2-TZZ01

T11-814NR-0.2-TZZ01
SCHURTER

T11-814NR-0.3-TZZ01

T11-814NR-0.3-TZZ01
SCHURTER

T11-814NR-0.5

T11-814NR-0.5
SCHURTER

T11-814NR-0.5-TZZ01

T11-814NR-0.5-TZZ01
SCHURTER

T11-814NR-0.7-TZZ01

T11-814NR-0.7-TZZ01
SCHURTER

T11-814NR-0.9-TZZ01

T11-814NR-0.9-TZZ01
SCHURTER

T11-814NR-1.4-TZZ01

T11-814NR-1.4-TZZ01
SCHURTER

T11-814NR-1.5-TZZ01

T11-814NR-1.5-TZZ01
SCHURTER