TF600 [SCHURTER]

Surface Mount Fuse, 10.1 x 3.22 mm, Time-Lag T, Telecom; 表面贴装保险丝, 10.1 X 3.22毫米,延时T,电信
TF600
型号: TF600
厂家: SCHURTER INC.    SCHURTER INC.
描述:

Surface Mount Fuse, 10.1 x 3.22 mm, Time-Lag T, Telecom
表面贴装保险丝, 10.1 X 3.22毫米,延时T,电信

电信
文件: 总4页 (文件大小:1721K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Telecom Fuses  
TF 600  
www.schurter.com/pg0ꢀ_3  
Surface Mount Fuse, 10.1 x 3.22 mm, Time-Lag T, Telecom  
Telcordia GR-1089 · 600VAC · 125VDC · Time-Lag T  
Description  
Applications  
-ꢀDirectlyꢀsolderableꢀonꢀprintedꢀcircuitꢀboards  
-ꢀTwistedꢀpairꢀtelecomꢀportsꢀrequiringꢀTelcordiaꢀGR-1089ꢀ/ꢀTIA-968-Aꢀ/ꢀ  
ITU-Tꢀ/ꢀULꢀ60950ꢀ/ꢀIECꢀ60950ꢀcompliance  
-ꢀseeꢀfollowingꢀpages  
Standards  
-ꢀIECꢀ60127-4  
-ꢀULꢀ248-14  
References  
-ꢀCSAꢀC22.2ꢀno.ꢀ248.14  
-ꢀTelcordiaꢀGR-1089  
-ꢀULꢀ60950ꢀ/ꢀIECꢀ60950  
-ꢀITU-TꢀK.20ꢀandꢀK.21  
-ꢀTIA-968-A  
GeneralꢀProductꢀInformation  
PackagingꢀDetails  
Weblinks  
Approvals,ꢀRoHS,ꢀCHINA-RoHS,ꢀe-Store,ꢀDistributor-Stock-Check,ꢀ  
Accessories,ꢀProductꢀChangeꢀNotificationꢀ(PCN)  
Approvals  
-ꢀULꢀFileꢀNumber:ꢀE41599  
Technical Data  
RatedꢀVoltage  
RatedꢀCurrent  
BreakingꢀCapacity  
Characteristic  
Mountingꢀ  
600VAC,ꢀ125VDC  
0.5ꢀ-ꢀ2A  
60A  
Time-LagꢀT  
PCB,SMT  
SolderingꢀMethods  
Solderability  
Reflow  
245°Cꢀ/ꢀ3secꢀacc.ꢀtoꢀIECꢀ60068-2-58,ꢀ  
TestꢀTd  
ResistanceꢀtoꢀSolderingꢀHeat 260°Cꢀ/ꢀ10secꢀacc.ꢀtoꢀIECꢀ60068-2-58,ꢀ  
TestꢀTd  
Flammability  
min.ꢀULꢀ94V-1ꢀ  
(acc.ꢀtoꢀEIA/IS-722,ꢀTestꢀ4.12)  
AdmissibleꢀAmbientꢀAirꢀTemp. -55°Cꢀtoꢀ125°C  
ClimaticꢀCategory  
Material:ꢀHousing  
Material:ꢀTerminals  
UnitꢀWeight  
55/125/21ꢀacc.ꢀtoꢀIECꢀ60068-1  
Ceramic  
Tin-PlatedꢀCopperꢀAlloy  
0.23ꢀg  
StorageꢀConditions  
ProductꢀMarking  
0°Cꢀtoꢀ60°C,ꢀmax.ꢀ70%ꢀr.h.  
,ꢀType,ꢀCurrent,ꢀCharacteristic  
Dimensions  
ꢀ10.1ꢀmm  
1.6 0.4 1.43  
2
6.5  
0.2ꢀ  
10.1  
Soldering pads  
Pre-Arcing Time  
Rated Current In  
ꢀ.0 x In min. 2.5 x In min. 2.5 x In max  
0.5 A - 2 A  
4 h  
1 s  
120 s  
Fuses  
Telecom Fuses  
TF 600  
www.schurter.com/pg0ꢀ_3  
Variants  
Rated Cur-  
rent [A]  
Rated Vol-  
tage [VAC]  
Voltage Drop  
ꢀ.0 In typ.  
[mV]  
Cold Resi-  
stance typ.  
[m]  
Melting I²t  
ꢀ0.0 Intyp.  
[A²s]  
Order Number  
0.5  
1.25  
2
600  
600  
600  
107  
94  
210  
73.2  
27.8  
1.14  
21.4  
22.3  
2000.0010  
2000.0011  
2000.0012  
55  
1)ꢀ60ꢀAꢀ@ꢀ600ꢀVACꢀ/ꢀ60ꢀAꢀ@ꢀ125ꢀVDC  
.xxꢀ=ꢀ.11ꢀPlasticꢀBagꢀ(100ꢀpcs.)  
.xxꢀ=ꢀ.24ꢀBlisterꢀTapeꢀ33ꢀcmꢀReelꢀ(2000ꢀpcs.)  
Packaging Unit  
[Kennlinien]  
10000  
1000  
100  
0.5 A  
1.25 A  
2.0 A  
10  
1
0.1  
0.01  
0.001  
0.0001  
100  
0.1  
1
10  
Current in Amperes  
Fuses  
2
Telecom Fuses  
TF 600  
www.schurter.com/pg0ꢀ_3  
GLOBAL TELECOM STANDARDS  
Customer Premises Equipment (CPE)  
Access Network Equipment  
Central Office Equipment  
Intra-Building Wiring  
ADSL Modem  
Splitter  
NID  
MDF  
MDF  
DSL = Digital Subscriber Line  
MDF = Main Distribution Frame  
NID = Network Interface Device  
NID  
POTS = Plain Old Telephone Service  
North America  
UL 60950  
Powered IT Safety  
Telcordia GR-974 + Telcordia GR-1361  
Telcordia GR-1089  
Primary Protection  
Equipment  
Secondary Protection  
TIA-968-A  
International  
IEC 60950 + ITU-T K.50 + ITU-T K.51  
ITU-T K.12 + ITU-T K.28  
ITU-T K.45/44  
Powered IT Safety  
Primary Protection  
ITU-T K.21/44  
ITU-T K.20/44  
Equipment  
Secondary Protection  
HOW TO SELECT THE RIGHT FUSE-LINK FOR SECONDARY PROTECTION?  
1. Select your equipment type  
2. Use the Key Device Selection Criteria to determine best suitability for your application  
Application  
Specification  
Key Device Selection Criteria  
Faster Time-to-Open Cooler Surface Temperature  
Customer Premises Equipment (CPE)  
TIA-968-A  
TF 600, 0.5 A (2000.0010.xx) TF 600, 2 A (2000.0012.xx)  
Modems (Analog, V.90, ISDN, xDSL), ADSL splitters, phone sets, fax machines,  
answering machines, caller ID, internet appliance, PBX systems, POS terminals  
Access Network Equipment  
UL 60950/IEC 60950 TF 600, 1.25 A (2000.0011.xx)  
ITU-T K.21/44  
Telcordia GR-1089  
TIA-968-A  
TF 600, 1.25 A (2000.0011.xx) TF 600, 2 A (2000.0012.xx)  
Remote terminals, line repeaters, muliplexers, cross-connects  
UL 60950/IEC 60950  
ITU-T K.45/44  
Central Office Equipment  
Telcordia GR-1089  
TIA-968-A  
TF 600, 1.25 A (2000.0011.xx) TF 600, 2 A (2000.0012.xx)  
Analog linecards (SLIC), ISDN linecards, xDSL modems,  
ADSL/VDSL splitters, T1/E1 linecards, muliplexers, servers  
UL 60950/IEC 60950  
ITU-T K.20/44  
Fuses  
3
Telecom Fuses  
TF 600  
www.schurter.com/pg0ꢀ_3  
3. Use Agency Specification based on the requirement  
Lighting Surge Specifications  
Surges are short-duration increases in system voltage due to external events, such as lightning  
Telcordia  
First Level  
First Level  
First Level  
First Level  
First Level  
Second Level  
GR-1089  
Test 1  
600  
100  
10x1000  
25  
*
Test 2  
1000  
100  
10x360  
25  
Test 3  
1000  
100  
10x1000  
25  
*
Test 4  
2500  
500  
2x10  
10  
Test 5  
1000  
25  
10x360  
5
Test 1  
6000  
500  
2x10  
1
Surge Voltage [V]  
Surge Current [A]  
Waveform [us]  
Repetitions [each polarity]  
2000.0010.xx, 0.5 A  
2000.0011.xx, 1.25 A  
2000.0012.xx, 2.0 A  
*
*
Equipment under test can not be damaged & must continue to operate properly  
* If sufficient series resistance is used, the 0.5 A fuse may pass Test 1-4  
TIA-968-A  
Type A  
Type A  
Type B  
Type B  
(former FCC Part 68) Metallic  
Longitudinal  
Metallic  
1000  
25  
5x320  
1
Longitudinal  
ITU-T K.20  
Surge Voltage [V]  
Test  
1000  
67  
10x700  
10  
Surge Voltage [V]  
Surge Current [A]  
800  
100  
1500  
200  
10x160  
1
Fuse open  
1500  
37.5  
5x320  
1
Surge Current [A]  
Waveform [us]  
Repetitions [each polarity]  
2000.0010.xx, 0.5 A  
2000.0011.xx, 1.25 A  
2000.0012.xx, 2.0 A  
Waveform [us]  
10x560  
1
Fuse open  
Repetitions [each polarity]  
2000.0010.xx, 0.5 A  
2000.0011.xx, 1.25 A  
2000.0012.xx, 2.0 A  
26 A*  
Fuse can not open during type B events  
Fuse does not open during test  
* If sufficient series resistance is used, the 0.5 A fuse may pass  
Power Cross Specifications  
A power-cross is an instance where a high-voltage circuit is inadvertently connected to a low-voltage circuit;  
for example, a power line can fall onto a telephone line during a storm initiating a power-cross event.  
Telcordia  
First Level First Level First Level First Level First Level First Level First Level First Level First Level  
GR-1089  
Voltage [Vrms]  
Overload Current [A]  
Duration  
Test 1  
50  
0.33  
Test 2  
100  
0.17  
Test 3  
200, 400, 600  
1
Test 4  
1000  
1
Test 5  
see GR-1089  
Test 6  
600  
0.5  
Test 7  
440  
2.2  
Test 8  
600  
3
Test 9  
1000  
5
15 min.  
15 min.  
60x1 s  
60x1 s  
60x5 s  
30 s  
5x2 s  
1.1 s  
0.5 s  
2000.0010.xx, 0.5 A  
2000.0011.xx, 1.25 A  
2000.0012.xx, 2.0 A  
Fuse not allowed to open  
Telcordia  
Second Level Second Level Second Level Second Level Second Level  
ITU-T K.20  
Power  
Power  
GR-1089  
Voltage [Vrms]  
Test 1  
120, 277  
25  
15 min.  
Test 2  
600  
60  
5 s  
Test 3  
600  
7
5 s  
Test 4  
100-600  
2.2  
15 min.  
Test 5  
see GR-1089  
Induction Contact  
Voltage [Vrms]  
Current [A]  
Duration  
300  
0.5  
250  
60  
Overload Current [A]  
Duration  
2000.0010.xx, 0.5 A  
2000.0011.xx, 1.25 A  
2000.0012.xx, 2.0 A  
15 min.  
200 ms  
5
15 min.  
1
Repetitions  
*  
*  
2000.0010.xx, 0.5 A  
*  
2000.0011.xx, 1.25 A ✓  
2000.0012.xx, 2.0 A  
*  
*  
Fuse opens in a safe and controlled manner before wiring simulator fuse (MDL 2.0)  
* Fuse does not open during test  
Fuse does not open during test  
* Fuse opens during test  
UL 60950  
Longitudinal Longitudinal Longitudinal Longitudinal Longitudinal  
Metallic Metallic Metallic Metallic  
IEC 60950  
Voltage [V]  
Current [A]  
Test 1  
600  
40  
Test 2  
600  
7
Test 3  
600  
2.2  
Test 4  
200  
2.2  
Test 5  
120  
25  
Test 1  
600  
40  
Test 2  
600  
7
Test 3  
600  
2.2  
Test 4  
600  
2.2  
Time  
1.5 s  
5 s  
30 min.  
30 min.  
30 min.  
1.5 s  
5 s  
30 min.  
30 min.  
2000.0010.xx, 0.5 A  
2000.0011.xx, 1.25 A  
2000.0012.xx, 2.0 A  
*  
*  
*  
*  
*  
*  
*  
*  
Fuse opens in a safe and controlled manner before wiring simulator fuse (MDL 2.0)  
* Fuse does not open during test  
Theꢀspecifications,ꢀdescriptionsꢀandꢀillustrationsꢀindicatedꢀinꢀthisꢀdocumentꢀareꢀbasedꢀonꢀ  
Fuses  
currentꢀinformation.ꢀAllꢀcontentꢀisꢀsubjectꢀtoꢀmodificationsꢀandꢀamendments.  

相关型号:

TF6001

TF6001为香港兴堡电子旗下的德国公司Telefunkenth自主设计开发的DC/DC高效率IC.可以替代MPS的MP2309. 价格比其低! 输出1A,Vin=4.5-23v.效率90%以上.固定频率340KHZ.
ETC

TF6002

本IC为德国TELEFUKEN公司研发的DC/DC 可调节IC, 输入电源4.5v--26v, 输出0.923--23v 满载效率可达90%以上. 与替代MP2305 ,MP1482
ETC

TF6003

本IC为德国TELEFUKEN公司研发的DC/DC 的可调节IC,输入电源4.5v--26v,输出0.923--23v 最大输出电流3A 满载效率可达90%以上. 与替代MP2307.
ETC

TF6006

TF6006为德国公司Telefunkenth自主设计开发的DC/DC高效率IC. 价格比其低!输出1A,Vin=4.5-23v.效率90%以上.固定频率500KHZ,最大输出电流500mA. 香港兴堡电子 联系电话:33201607 QQ:1583518250
ETC

TF601

6 Amp Fast Recovery Rectifier
TAITRON

TF601L

6.0A Fast Recovery Rectifier
TAITRON

TF601LG

6.0A Glass Passivated Fast Recovery Rectifier
TAITRON

TF602

6 Amp Fast Recovery Rectifier
TAITRON

TF6029S

Common Mode Choke Coils Line Filters for AC Power Supply Toroidal Core Type
TDK

TF6029S-102Y20R-01

Single Phase EMI Filter
TDK

TF6029S-102Y20R0-01

Common Mode Choke Coils Line Filters for AC Power Supply Toroidal Core Type
TDK

TF6029S-102Y30R-02

Single Phase EMI Filter
TDK