TS3-D0A3X [SEIKO]

Crystal Filter, 1 Function(s), 120MHz, 14kHz BW(delta f), Monolithic;
TS3-D0A3X
型号: TS3-D0A3X
厂家: SEIKO EPSON CORPORATION    SEIKO EPSON CORPORATION
描述:

Crystal Filter, 1 Function(s), 120MHz, 14kHz BW(delta f), Monolithic

LTE
文件: 总13页 (文件大小:726K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MCF (Monolithic Crystal Filters)  
• General.............................................................................................2  
• Basic Structure ..............................................................................3  
• Measurement ..................................................................................4  
• Terms and Definition.....................................................................5  
• MCF LINE UP .................................................................................6  
• Product Data  
for Cellular IF (PDC) .....................................................................7  
for Cellular IF (TDMA)...................................................................8  
for Cellular IF (AMPS)...................................................................9  
for Base station (GSM),Pager IF,Radio application equipment ...10  
• Outline Drawing............................................................................11  
• Reference Footprint ....................................................................12  
• PACKAGING (Tape and Reel)....................................................13  
1
MCF (CRYSTAL FILTER)  
General  
A MCF (Monolithic Crystal Filter) is a filter that works by using a mechanical combination between mounted electrodes on a piezoelectric  
substrate. In 1962, TOYOCOM developed the world's first MCF. Since then, TOYOCOM have developed many kinds of compact, high  
reliability filters covering a wide range of frequencies.  
The following diagrams show the basic structure and equivalent circuits of a 2-pole MCF  
Range of nominal frequency and band pass that is made available with a MCF  
100  
Transversal type SAW Filter  
10–1  
Dual Mode SAW  
(DMS) Filter  
10–2  
10–3  
MCF  
HFF-MCF  
Note 1  
1000  
10–4  
10–5  
1
10  
100  
10000  
Frequency (MHz)  
Note1. HFF-MCF (High Frequency Fundamental MCF) is the product name of a VHF fundamental mode MCF  
developed by TOYOCOM.  
2
MCF (CRYSTAL FILTER)  
Basic Structure  
Crystal plate  
Electrodes  
2-pole MCF basic structure  
Equivalent circuit  
Crystal plate  
Electrodes  
3-pole MCF basic structure  
Equivalent circuit  
Thus, a 2-pole filter or a 3-pole filter can be made according to the number of electrodes built on one crystal plate. A 3-pole MCF can obtain  
a steeper attenuation curve compared with a 2 pole MCF.  
Comparison of characteristics: 2-pole type MCF and 3-pole type MCF  
(Comparison of characteristics at 45MHz)  
0
5
0
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
10  
15  
20  
25  
30  
35  
40  
45  
50  
2-pole  
2-pole  
3-pole  
3-pole  
SPAN 100 kHz  
CENTER 45.000 MHz  
SPAN 2 MHz  
CENTER 45.000 MHz  
3
MCF (CRYSTAL FILTER)  
Measurement  
(1) Measurement of attenuation value and group delay  
The attenuation value and group delay are measured with a network analyzer. A test jig with a built-in impedance matching circuit between  
a network analyzer (50 ohms) and a MCF (Zt) is used for the accurate measurement of filter impedance Zt.  
Network  
analyzer  
(50)  
(50)  
Test fixture  
Matching circuit  
Filter  
Zt  
Zt  
Block type and 1-pole resonator type measurement  
(2) Intermodulation measurement  
a
b
SG1  
Test fixture  
f1= fo f  
Spectrum analyzer  
Filter  
Zt  
Zt  
SG2  
f2= fo 2f  
Test circuit for measuring intermodulation characteristics  
Two methods are used for the expression of intermodulation characteristics:  
IM and IP. The concept of each measurement method is explained below.  
Reference level point  
"a" (L dBm)  
Reference level point  
"a" (L dBm)  
B dB  
Measurement level point "b" (M dBm)  
fo  
fo+f  
fo+2f  
fo  
fo+f  
fo+2f  
f1  
f2  
Spectrum at point "b"  
Spectrum at point "a"  
IM = B  
= L M (dB)  
1
2
Ip = L +  
B
(dBm)  
4
MCF (CRYSTAL FILTER)  
Terms and Definition  
Term  
Reference symbol  
fo (MHz)  
Definition  
Nominal frequency  
Passband (PB)  
A frequency given in specification, to which other frequencies may be referred.  
B1 (kHz)  
A1 (dB)  
A band of frequencies B1 in which the attenuation is equal to or less than a  
specified value A1 (IF).  
A band of frequencies B1 in which the attenuation is equal to or less than the  
insertion loss L (RF).  
The logarithmic ratio of the power delivered to the load impedance before  
insertion of the filter to the power delivered to the load impedance after insertion  
of the filter.  
Insertion loss  
Ripple  
L (dB)  
R (dB)  
The difference between the minimum peak attenuation and the maximum peak  
attenuation within an passband.  
Bands of frequencies B2 and B3 in which the attenuations are equal to or greater  
than specified values A2 and A3 respectively.  
Stopband attenuation B2 (kHz), A2 (dB)  
B3 (kHz), A3 (dB)  
Guaranteed attenuation A3 (dB)  
The maximum guaranteed attenuation at the specified frequency range.  
Spurious response  
A4 (dB)  
Minimum attenuation caused by extraordinary response in the stopband. Spurious  
response usually appears at a higher frequency than the center frequency.  
Group delay distortion t (µSec)  
The difference between the maximum and minimum group delay within a  
passband B1 unless otherwise specified.  
Either of the impedances presented to the filter by the source or by the load.  
(Rt: Resistive portion Ct: Parallel capacitive portion including stray capacitance)  
Terminating impedance  
Coupling impedance  
Zt: Rt//Ct (//pF)  
Zc (pF)  
The impedance inserted between the filter elements when the filter is composed  
of two or more elements.  
fo  
L
0 dB  
for reference attenuation  
A1  
R
B1  
t  
Group Delay Curve  
A3  
A2  
A4  
Attenuation  
Curve  
(µsec)  
B3  
B2  
(dB)  
5
MCF (CRYSTAL FILTER)  
MCF Line up  
Number  
Frequency  
of  
Bandwidth  
(kHz/dB)  
Application  
PDC  
Type  
Package  
Page  
P7  
(MHz)  
pole  
TF2-D0AD6  
TF2-D0AC5  
TF3-D0AD7  
TS3-D0A31  
TF2-D0AC5  
TS3-D0A3X  
TF3-D0ACX  
TF3-J3DC5  
TS3-A9A31  
TF4-71GX2  
TS2-21B01  
TS2-21B02  
TS2-45A01  
TS3-45A01  
TS-2520  
TS-30  
2
130.05  
*
10.5/1  
TS-2520  
TS-38  
3
130  
*
Cellular  
IF  
2
15/3  
14/3  
TS-30  
TDMA  
AMPS  
100 to 140  
P8  
TS-38  
3
183.6  
13/3  
14/3  
80/3  
TS-30  
TS-38  
S-436  
P9  
100 to 140  
4
P10  
P10  
71  
Base station (GSM)  
Pager IF  
21.4  
7.5/3  
15/3  
2
TS-75  
TS-75  
21.7  
2
45  
Radio application equipment  
P10  
3
The other frequencies or specifications are available upon your request.  
*
6
MCF (CRYSTAL FILTER)  
Product Data  
for Cellular IF (PDC)  
Specifications  
Guaranteed  
attenuation  
Number  
of  
Insertion  
loss  
dB  
Terminating  
impedance  
Zt (//pF)  
Passband  
dB kHz  
Stopband  
Nominal  
Type  
Ripple  
dB  
Package  
fo (MHz)  
dB  
kHz  
dB  
70  
kHz  
pole  
TF2-D0AD6  
TS-2520  
TS-30  
2
3
100  
50  
3
200//1.7  
TF2-D0AC5  
TF3-D0AD7  
TS3-D0A31  
130.05  
*
1
10.5  
20  
1
900  
4
3
250//1.0  
950//1.2  
TS-2520  
TS-38  
130  
*
The other frequencies or specifications are available upon your request.  
(Operating temperature range : 30 to +80°C)  
*
Electrical Data  
TF2-D0AD6  
TF2-D0AC5  
0
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
0
1
0
1
2
3
4
5
6
7
8
9
0
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
A
A
2
3
30  
25  
20  
15  
10  
5
4
30  
25  
20  
15  
10  
5
B
B
5
6
C
C
7
8
9
0
10  
A: 0.06  
B: 1  
10  
A: 0.05  
B: 1  
0
fo  
fo  
+0.05  
+1  
+0.06  
+1  
FREQUENCY(MHz)  
FREQUENCY(MHz)  
TF3-D0AD7  
TS3-D0A31  
0
1
0
1
2
3
4
5
6
7
8
9
0
10  
20  
30  
40  
50  
60  
70  
80  
90  
0
10  
20  
30  
40  
50  
60  
70  
80  
90  
A
2
3
A
B
C
B
4
40  
35  
30  
25  
20  
15  
0
40  
35  
30  
25  
20  
15  
0
5
C
6
7
8
9
10  
A: 0.025  
B: 1  
10  
A: 0.025  
B: 1  
100  
+0.025  
+1  
100  
+0.025  
+1  
fo  
fo  
FREQUENCY(MHz)  
FREQUENCY(MHz)  
7
MCF (CRYSTAL FILTER)  
Product Data  
for Cellular IF (TDMA)  
Specifications  
Guaranteed  
attenuation  
Number  
of  
Insertion  
loss  
dB  
Terminating  
impedance  
Zt (//pF)  
Passband  
dB kHz  
Stopband  
Ripple  
dB  
Nominal  
Type  
Package  
fo (MHz)  
pole  
dB  
kHz  
60  
dB  
70  
kHz  
TF2-D0AC5  
2
3
15  
14  
10  
20  
200//1.7  
TS-30  
TS-38  
TS3-D0A3X  
TF3-D0ACX  
100 to 140  
3
1
3
900  
900//0.9  
50  
Balanced  
*
(Operating temperature range : 30 to +80°C)  
The other specifications are available upon your request.  
*
Electrical Data  
TF2-D0AC5  
TS3-D0A3X  
0
0
1
0
0
10  
20  
30  
40  
50  
60  
70  
80  
90  
1
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
A
2
3
4
2
A
3
B
4
30  
25  
20  
15  
10  
5
40  
35  
30  
25  
20  
15  
10  
B
5
5
6
6
7
C
8
7
8
C
9
9
10  
A: 0.06  
B: 1  
10  
A: 0.025  
B: 1  
0
100  
+0.025  
+1  
fo  
fo  
FREQUENCY(MHz)  
+0.06  
+1  
FREQUENCY(MHz)  
TF3-D0ACX  
0
1
2
3
4
5
6
7
8
9
0
10  
20  
30  
40  
50  
60  
70  
80  
90  
A
B
10  
A: 0.025  
B: 0.5  
100  
+0.025  
+0.5  
fo  
FREQUENCY(MHz)  
8
MCF (CRYSTAL FILTER)  
Product Data  
for Cellular IF (AMPS)  
Specifications  
Guaranteed  
attenuation  
Number  
of  
pole  
Insertion  
loss  
dB  
Terminating  
impedance  
Zt (//pF)  
Passband  
dB kHz  
Stopband  
Nominal  
Type  
Ripple  
dB  
Package  
fo (MHz)  
dB  
kHz  
dB  
kHz  
TF3-J3DC5  
TS3-A9A31  
183.6  
13  
14  
60  
50  
4.5  
3
150//0.8  
TS-30  
TS-38  
3
3
20  
1
100 to 140  
70  
900  
2000//0.6  
(Operating temperature range : 30 to +80°C)  
Electrical Data  
TS3-A9A31  
TF3-J3DC5  
0
1
0
1
2
3
4
5
6
0
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
0
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
A
2
A
B
3
4
30  
B
5
30  
25  
20  
15  
10  
5
25  
20  
15  
10  
5
6
7
7
C
8
8
9
C
9
10  
A: 0.03  
B: 1  
10  
A: 0.03  
B: 1  
0
fo  
FREQUENCY(MHz)  
fo  
+0.03  
+1  
+0.03  
+1  
FREQUENCY(MHz)  
9
MCF (CRYSTAL FILTER)  
Product Data  
for Base Station (GSM), Pager IF, Radio application equipment  
Specifications  
Guaranteed  
attenuation  
Insertion  
loss  
dB  
Terminating  
impedance  
Zt (//pF)  
Number  
of  
Passband  
dB kHz  
Stopband  
Nominal  
fo (MHz)  
Ripple  
dB  
Type  
Package  
S-436  
dB  
kHz  
200  
dB  
70  
kHz  
pole  
TF4-71GX2  
TS2-21B01  
TS2-21B02  
TS2-45A01  
TS3-45A01  
71  
4
2
3
80  
28  
15  
20  
6
2
800  
910  
50//0  
21.4  
21.7  
7.5  
25  
60  
1500//2.5  
3
1
TS-75  
1100//0  
45  
15  
3
1200//1  
(Operating temperature range : 30 to +80°C)  
Electrical Data  
TS2-21B01  
TF4-71GX2  
4
5
0
1
0
10  
20  
30  
40  
50  
60  
70  
80  
90  
0
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
A
6
2
A
7
3
8
4
10  
B
B
9
5
9
8
7
6
5
4
10  
11  
12  
13  
14  
6
7
8
9
C
10  
A: 0.125  
B: 0.5  
100  
+0.125  
+1  
A: 0.125  
B: 1  
fo  
fo  
+0.125  
+0.5  
FREQUENCY(MHz)  
FREQUENCY(MHz)  
TS2-21B02  
TS2-45A01  
0
10  
20  
30  
40  
50  
60  
70  
80  
90  
0
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
A
B
A
B
100  
+0.125  
+0.5  
10  
A: 0.125  
B: 0.5  
10  
A: 0.025  
B: 1  
fo  
fo  
+0.025  
+1  
FREQUENCY(MHz)  
FREQUENCY(MHz)  
TS3-45A01  
0
1
2
3
4
5
6
7
8
9
0
10  
20  
30  
40  
50  
60  
70  
80  
90  
A
B
10  
A: 0.025  
B: 1  
100  
+0.025  
+1  
fo  
FREQUENCY(MHz)  
10  
MCF (CRYSTAL FILTER)  
Outline Drawing [mm]  
TS-2520  
TS-30  
0.1  
3
0.15  
0.05  
0.90  
2.5  
Marking  
Marking  
(G)  
(G)  
(OUT)  
0.8  
C0.3  
(G)  
(OUT)  
(G)  
(G)  
(G)  
(IN)  
(G)  
(0.1)  
(0.55)  
(G)  
(0.5)  
1.4  
(G)  
(IN)  
(G)  
1.4  
TS-38  
TS-75  
0.1  
0.2  
1.3 0.2  
3.8  
1.0  
7.0 0.2  
Marking  
Marking  
0.2  
0.3  
(G)  
1.2  
(G)  
(G)  
(OUT)  
(G)  
(G)  
(IN)  
(I/O)  
(G)  
(G)  
(I/O)  
(G)  
(G)  
8-0.6  
(G)  
0.1  
0.1  
7-1.0  
1.0  
4.6  
S-436  
26.0  
Index  
Marking  
4-Trimming holes  
1.8  
(G) (G) (G) (G) (OUT)  
(G)  
(G)  
(IN) (G) (G) (G) (G)  
10.16  
20.32  
11  
MCF (CRYSTAL FILTER)  
Reference Footprint [mm]  
TS-2520  
TS-30  
1.15  
1.15  
1.95  
(IN)  
(OUT)  
0.65  
0.6  
0.65  
1.0  
0.6  
1.0  
TS-38  
TS-75  
1.58  
1.58  
3.0  
3.0  
1.4  
2.0  
2.0  
1.35  
0.7  
1.35  
12  
MCF (CRYSTAL FILTER)  
PACKAGING (Tape and Reel)[mm]  
TS-2520, 30, 38, 75  
120˚  
0.5  
2.0  
0.2  
ø13.0  
A
B
0.1  
0.1  
0.05  
4.0  
2.0  
ø1.55  
0.3 0.05  
E
H
I
C
A
17.0  
13.0  
9.0  
B
19.4  
15.4  
11.4  
11.4  
C
D
E
F
G
H
I
1.55  
1.55  
1.05  
1.05  
0.3  
0.3  
1.0  
1.0  
1.0  
1.0  
0.1  
0.1  
0.1  
0.1  
0.1  
0.5  
0.1  
0.3  
0.1  
0.1  
0.1  
0.1  
0.05  
0.05  
0.1  
TS-75  
TS-38  
TS-30  
5.5  
7.5  
4.25  
3.2  
1.8  
1.35  
1.5  
7.5  
16.0  
8.0  
0.1  
0.1  
0.1  
0.1  
0.1  
0.2  
4.25  
3.2  
5.5  
3.5  
3.5  
12.0  
8.0  
8.0  
4.0  
4.0  
0.3  
0.3  
0.1  
0.1  
0.1  
0.1  
0.2  
0.2  
0.1  
TS-2520 9.0  
2.3  
2.8  
1.15  
8.0  
S-436  
6-ø 10  
ø 10  
ø 13  
ø 21  
2.8  
Order no.  
Item  
Spec no.  
Quant.  
TOYOCOM  
BIAJ-RRM 44DC  
GR  
45.5  
49.5  
Direction of pulling out of the reel  
4 0.1 ø2.05 0.1  
2 0.15  
ø1.55 0.05  
5.4 0.1  
24 0.1  
(0.4)  
16.5 0.1  
2-R0.75  
13  

相关型号:

TS300

FAST SWITCHING PLASTIC RECTIFIER
TRSYS

TS3001

A 1V/1uA Easy-to-Use Resistor-Tuned Silicon Oscillator/Timer
TOUCHSTONE

TS30011

High Efficiency 1A/2A/3A Current-Mode Synchronous Buck DC/DC Converter, 1MHz
SEMTECH

TS30011-M000

High Efficiency 1A/2A/3A Current-Mode Synchronous Buck DC/DC Converter, 1MHz
SEMTECH

TS30011-M000QFNR

Switching Regulator,
SEMTECH

TS30011-M015

High Efficiency 1A/2A/3A Current-Mode Synchronous Buck DC/DC Converter, 1MHz
SEMTECH

TS30011-M015QFNR

Switching Regulator
SEMTECH

TS30011-M018

High Efficiency 1A/2A/3A Current-Mode Synchronous Buck DC/DC Converter, 1MHz
SEMTECH

TS30011-M018QFNR

Switching Regulator,
SEMTECH

TS30011-M025

High Efficiency 1A/2A/3A Current-Mode Synchronous Buck DC/DC Converter, 1MHz
SEMTECH

TS30011-M025QFNR

Switching Regulator
SEMTECH

TS30011-M033

High Efficiency 1A/2A/3A Current-Mode Synchronous Buck DC/DC Converter, 1MHz
SEMTECH