CTU8002AD4 [SENSORTECHNICS]
OEM pressure transmitters for industrial media; OEM压力变送器行业媒体型号: | CTU8002AD4 |
厂家: | SENSORTECHNICS GMBH |
描述: | OEM pressure transmitters for industrial media |
文件: | 总6页 (文件大小:244K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
CTE8000 / CTU8000 Series
OEM pressure transmitters for industrial media
FEATURES
· 0...-1 to 0...100 bar,
0...-15 to 0...1500 psi
gage1 or absolute10
· For many industrial gases and liquids
· 0...10 V, 0.5...4.5 V, 0...5 V, 1...6 V or
4...20 mA output
· Field interchangeable
· For industrial use
MEDIA COMPATIBILITY
Wetted materials:
stainless steel 1.4404 (316L), ceramicAL2O3, NBR9
Housing:
stainless steel,protection class IP 64 (according to
DIN EN 60529) respectively NEMA 4X1
SPECIFICATIONS11,12
ELECTRICAL CONNECTION
Maximum ratings
0...10 V, 0.5...4.5 V, 0...5 V, 1...6 V output
Supply voltage (reverse polarity protection)
+Vs
12...30 V
9...30 V
9...30 V
CTx8...0
12 (9) to 30 V
CTx8...1, ...6, ...7
1
Vout
CTx8...42
sensor
2
-Vs
V
Maximum load current (source)
CTx8...0, ...1, ...6, ...7
1 mA
GND
4
case
Temperature limits
Storage
3
-55 to 100°C
-40 to 100°C
0 to 70°C
Operating8
4...20 mA output
Compensated
+Vs
9 to 30 V
1
N/C
0 - 98 %RH
10 gRMS
Humidity limits
sensor
Vibration (5 to 500 Hz)
Mechanical shock
Proof pressure3
V
2
R
L
-Vs
50 g
4
case
3
GND
2 x rated pressure
December 2008 / 508
1/6
www.sensortechnics.com
CTE8000 / CTU8000 Series
OEM pressure transmitters for industrial media
COMMON PERFORMANCE CHARACTERISTICS
Characteristics
Min.
Typ.
Max.
Unit
Operating pressure
CTE8001...
CTE8N01...
CTE8P01...
0
-1
-1
1
+1
0
CTE8002...
CTE8005...
CTE8010...
CTE8016...
CTE8020...
CTE8025...
CTE8035...
CTE8050...
CTE8070...
CTE8100...
0
0
0
0
0
0
0
0
0
0
2
5
10
16
20
25
35
50
70
100
bar
CTU8015...
CTU8N15...
CTU8P15...
0
-15
-15
15
+15
0
CTU8030...
CTU8100...
CTU8200...
CTU8300...
CTU8500...
CTU8700...
CTU81K0...
CTU81K5...
0
0
0
0
0
0
0
0
30
100
200
300
500
700
1000
1500
psi
Thermal effectss
(0 to 70°C)4
Offset
Span
0.02
0.02
0.05
0.05
%FSO/°C
Thermal effects
Offset
Span
0.03
0.03
(-40 to 0°C, 70 to 100°C)
Non-linearity, hysteresis (BSL) and repeatability5
Long term stability6
±0.1
±0.3
±0.04
1
±0.3
5
%FSO
ms
Output noise (0 < f < 1 kHz)
Response time (10 to 90 %)
Power supply rejection
Offset
Span
CTx8...4
all others
0.05
0.002
%FSO/V
CTx8...4
all others
0.08
0.002
December 2008 / 508
2/6
www.sensortechnics.com
CTE8000 / CTU8000 Series
OEM pressure transmitters for industrial media
INDIVIDUAL PERFORMANCE CHARACTERISTICS
0...10 V output (VS = 15 V, RL > 100 kΩ, tamb = 25°C)
Characteristics
Min.
Typ.
5
Max.
5.1
0.1
5.1
10.1
25
Unit
Zero pressure offset
CT...8N...
all others
CT...8N...
all others
4.9
0.03
5
V
Full scale span7
4.9
9.9
10
Ω
Output impedance
Current consumption (no load)
3
5
mA
0.5...4.5 V output (VS = 15 V, RL > 100 kΩ, tamb = 25°C)
Characteristics
Min.
2.45
0.45
1.95
3.95
Typ.
2.5
0.5
2
Max.
2.55
0.55
2.05
4.05
25
Unit
Zero pressure offset
CT...8N...
all others
CT...8N...
all others
V
Full scale span7
4
Ω
Output impedance
Current consumption (no load)
3
5
mA
0...5 V output (VS = 15 V, RL > 100 kΩ, tamb = 25°C)
Characteristics
Min.
Typ.
2.5
Max.
2.55
0.08
2.55
5.05
25
Unit
Zero pressure offset
CT...8N...
all others
CT...8N...
all others
2.45
0.03
2.5
V
Full scale span7
2.45
4.95
5.0
Ω
Output impedance
Current consumption (no load)
3
5
mA
1...6 V output (VS = 15 V, RL > 100 kΩ, tamb = 25°C)
Characteristics
Min.
3.45
0.95
2.45
4.95
Typ.
3.5
1
Max.
3.55
1.05
2.55
5.05
25
Unit
Zero pressure offset
CT...8N...
all others
CT...8N...
all others
V
Full scale span7
2.5
5.0
Ω
Output impedance
Current consumption (no load)
3
5
mA
4...20 mA output (VS = 15 V, RL = 100 Ω, tamb = 25°C)
Characteristics
Min.
11.9
3.9
Typ.
12.0
4.0
Max.
12.1
4.1
Unit
mA
Zero pressure offset
CT...8N...
all others
CT...8N...
all others
Full scale span7
7.9
8.0
8.1
15.9
16.0
250
16.1
Power consumption (IL = 20 mA)
mW
December 2008 / 508
3/6
www.sensortechnics.com
CTE8000 / CTU8000 Series
OEM pressure transmitters for industrial media
Specification notes:
IP 64 protection is given when the connector is locked. For proper function the gage port is vented to the atmosphere through
the connector/cable assembly. Thus the cable end must have access to the ambient pressure.
The minimum supply voltage is directly proportional to the load resistance seen by the transmitter. For more details see the
load limitation diagram.
1.
2.
Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element.
Thermal effects tested and guaranteed from 0 to 70°C relative to 25°C. All specifications shown are relative to 25°C.
Non-linearity refers to the Best Straight Line fit measured for offset, full scale span and 1/2 full scale span.
Long term stability is the change in output after one year or 1 million pressure cycles.
Span is the arithmetic difference in transmitter output signal measured at zero pressure and the maximum operating pressure.
Tests are in accordance with EN61000-6-2, April 1999.
3.
4.
5.
6.
7.
8.
9.
Other material on special request. When using devices with optional nickel plated fittings, consider the media compatibility of
the fittings also.
Available for pressure ranges from 1 bar (15 psi) absolute upwards only.
CE-labelling is in accordance with 89/336/EEC.
The pressure transmitters must not be used as safety accessories according to article 1, 2.1.3 of the directive 97/23/EC.
10.
11.
12.
OUTLINE DRAWING
NOM 72 (2.83)
52 (2.05)
6.5
(0.26)
vent hole¹
4
1
3
2
Detail A
Detail A
Output
0...10 V
Pin
0.5...4.5 V
0...5 V, 1...6 V
+VS
4...20 mA
1
2
3
4
+VS
NC
Vout
case
case
-Vs
o-ring grove for
-Vs
o-ring 11.8 x 1.8
(0.456 x 0.071)
(ZA004029)
mass: 72 g
dimensions in mm (inches)
December 2008 / 508
4/6
www.sensortechnics.com
CTE8000 / CTU8000 Series
OEM pressure transmitters for industrial media
RECOMMENDED ACCESSORY (not included in delivery)
ZK000101:
Connector/cable assembly (different cable lenghts available)
ZP000112-B: Mating Connector (without cable)
PIN CONNECTION
Flying lead end
Brown
NOM 2 m
(other cable lenghts on request)
Pin
1
NOM 60
Shield
2
Green
3
White and shield
Yellow
4
Vent tube
Note:
For proper function of all gage
devices the vent tube must have
access to the ambient atmosphere.
M12x1
Ø 20
dimensions in mm
OPTIONAL PRESSURE FITTINGS
(brass, nickel plated)
LOAD LIMITATION
4...20 mA output version
1400
Ohm
B
C
Male
fittings
1200
A
D
1000
800
600
400
200
ng
i
t
a
e
r
e
ng
G
F
p
a
Female
fittings
o
r
E
H
0
5
16 20
25 30 V
9
supply voltage
Dimensions in mm (inches)
Dimensions in mm (inches)
A
B
C
D (Hex.)
14 (9/16")
14 (9/18")
17 (11/16")
22 (7/8")
E
F
G
H (Hex.)
14 (9/16")
17 (11/16")
22 (7/8")
1/8" BSPT
8 (0.315)
13 (0.512)
5.5 (0.217)
5 (0.197)
7 (0.276)
11 (0.433)
5 (0.197)
7 (0.276)
13 (0.512)
6 (0.236)
1/8" BSP
1/4" BSP
3/8" BSP
1/2" BSP
5 (0.197)
7 (0.276)
6 (0.236)
18 (0.707)
15 (0.591)
20 (0.787)
20 (0.787)
23 (0.906)
1/4" BSPT
3/8" BSPT
1/2" BSPT
1/8" BSP
1/4" BSP
3/8" BSP
1/8" NPT
1/4" NPT
12 (0.472)
11.5 (0.453)
16 (0.630)
12.5 (0.492)
8.5 (0.335)
12.5 (0.492)
10 (0.394)
14 (0.551)
24 (15/16")
14 (9/16")
19 (3/4")
22 (7/8")
17 (11/16")
22 (7/8")
December 2008 / 508
5/6
www.sensortechnics.com
CTE8000 / CTU8000 Series
OEM pressure transmitters for industrial media
ELECTROMAGNETIC CAPABILITY8
Test conditions
Criterion Interference
Radiated, radio frequency
electromagnetic field immunity (RFI)
EN61000-4-3: Grade 3, 10 V/m, 80 to 1000 MHz
80 % AMC (1 kHz)
A
B
B
A
<1 %FSO
<1 %FSO
<1 %FSO
<1 %FSO
Electrical fast transient /
burst immunity (EFT)
EN61000-4-4: Grade 3, ±2 kV
Electrostatic discharge immunity
test (ESD)
EN61000-4-2: Grade 4, ±8 kV, contact discharge
Immunity to conducted disturbances EN61000-4-6: Grade 3, 0.15 to 80 MHz
induced by radio-frequency fields
10 V, 80 % AMC (1 kHz)
ORDERING INFORMATION
CTx8
xxx
x
x
x
Output signal
E:
bar calibration
0:
1:
4:
6:
7:
0...10 V
1...6 V
4...20 mA
0.5...4.5 V
0...5 V
U: psi calibration
CTE8000 series
CTU8000 series
001:
0 to 1 bar
015:
0 to 15 psi
N01: -1 to +1 bar
N15: -15 to +15 psi
Fitting size
P01:
002:
005:
010:
016:
020:
025:
035:
050:
070:
0 to -1 bar
0 to 2 bar
0 to 5 bar
0 to 10 bar
0 to 16 bar
0 to 20 bar
0 to 25 bar
0 to 35 bar
0 to 50 bar
0 to 70 bar
P15:
030:
100:
200:
300:
500:
700:
0 to -15 psi
0 to 30 psi
0 to 100 psi
0 to 200 psi
0 to 300 psi
0 to 500 psi
0 to 700 psi
D: 1/8" BSPT male, brass, nickel plated
E: 1/4" BSPT male, brass, nickel plated
F: 3/8" BSPT male, brass, nickel plated
G: 1/2" BSPT male, brass, nickel plated
K: 1/8" NPT male, brass
L: 1/4" NPT male, brass
M: 1/8" NPT male, SS 1.4305 (303)
N: 1/4" NPT male, SS 1.4305 (303)
1K0: 0 to 1000 psi
1K5: 0 to 1500 psi
100: 0 to 100 bar
P: G 1/8" (BSP) male, brass, nickel plated
Q: G 1/4" (BSP) male, brass, nickel plated
R: G 3/8" (BSP) male, brass, nickel plated
S: G 1/2" (BSP) male, brass, nickel plated
Pressure mode
G: gage pressure1
A: absolute pressure10
U: G 1/8" (BSP) female, brass, nickel plated
V: G 1/4" (BSP) female, brass, nickel plated
W: G 3/8" (BSP) female, brass, nickel plated
X: G 1/2" (BSP) female, brass, nickel plated
Y: G 1/8" (BSP) male, SS 1.4404 (316)
no optional fitting
Note: Other pressure ranges and options are widely available.
Please contact your nearest Sensortechnics sales representative.
Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the
application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.
December 2008 / 508
6/6
www.sensortechnics.com
相关型号: