KTE6000 / KTU6000 Series
OEM pressure transmitters for industrial media
FEATURES
· 0...-1 to 0...400 bar
0...-15 to 0...6000 psi
gage1 or absolute
· For many industrial gases and liquids
· 0...10 V, 0.5...4.5 V, 0...5 V and
4...20 mA output
· Field interchangeable
· For industrial use
MEDIA COMPATIBILITY
Wetted materials:
stainless steel 1.4404 (316L), ceramicAl2O3, NBR9,
TPE9
Housing:
stainless steel, protection class IP 65 (according to
DIN EN 60529) respectively NEMA 4X1
SPECIFICATIONS11,12
ELECTRICAL CONNECTION
Maximum ratings
0...10 V, 0.5...4.5 V, 0...5 V output
Supply voltage (reverse polarity protection)
+Vs
1
KTx6...0
12...30 V
9...30 V
9...30 V
12 (9) to 30 V
KTx6...6, KTx6...7
KTx6...42
Vout
sensor
3
-Vs
Maximum load current (source)
KTx6...0, KTx6...6, KTx6...7
V
1 mA
GND
2
Temperature limits
Storage
-55 to 100°C
-40 to 100°C
0 to 70°C
Operating
Compensated
4...20 mA output
+Vs
9 to 30 V
1
Humidity limits
0 - 95 %RH
10 gRMS
50 g
N/C
sensor
Vibration (5 to 500 Hz)
Mechanical shock
V
3
R
-Vs
L
2
GND
Proof pressure3
400 bar (6000 psi)
all others
1.5 x rated pressure
2 x rated pressure
December 2008 / 550
1/6
www.sensortechnics.com
KTE6000 / KTU6000 Series
OEM pressure transmitters for industrial media
COMMON PERFORMANCE CHARACTERISTICS
VS = 15 V, RL > 100 kΩ, tamb = 25°C
Characteristics
Min.
Typ.
Max.
Unit
Operating pressure
KTE6001...
KTE6N01G...
KTE6P01G...
KTE6002...
KTE6005...
KTE6010...
KTE6016...
KTE6020...
KTE6025...
KTE6035...
KTE6050...
KTE6070...
KTE6100...
KTE6150...
KTE6200...
KTE6300...
KTE6400...
0
-1
-1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
0
2
5
10
16
20
25
35
50
70
100
150
200
300
400
bar
KTU6015...
KTU6N15G...
KTU6P15G...
KTU6030...
KTU6050...
KTU6100...
KTU6200...
KTU6300...
KTU6500...
KTU61K0...
KTU61K5...
KTU62K0...
KTU63K0...
KTU64K5...
KTU66K0...
0
-15
-15
0
0
0
0
0
0
0
15
15
0
30
50
100
200
300
500
1000
1500
2000
3000
4500
6000
psi
0
0
0
0
0
Thermal effects
(0 to 70°C)4
Offset
Span
0.02
0.02
0.05
0.05
%FSO/°C
%FSO
Thermal effects
Offset
Span
0.03
0.03
(-40 to 0°C, 70 to 100°C)
Non-linearity, hysteresis (BSL)
and repeatability5
Long term stability6
> 200 bar (3000 psi)
all others
±0.2
±0.1
±0.4
±0.3
±0.3
±0.04
1
Output noise (0 < f < 1 kHz)
Response time (10 to 90 %)
Power supply rejection
5
ms
Offset
Span
KTx6...0, ...6, ...7
KTx6...4
KTx6...0, ...6, ...7
KTx6...4
0.002
0.05
0.002
0.08
%FSO/V
December 2008 / 550
2/6
www.sensortechnics.com
KTE6000 / KTU6000 Series
OEM pressure transmitters for industrial media
INDIVIDUAL PERFORMANCE CHARACTERISTICS
0...10 V output (VS = 15 V, RL > 100 kΩ, tamb = 25°C)
Characteristics
Min.
Typ.
Max.
Unit
Zero pressure offset
4.9
5
0.03
5.1
0.1
KTx6N...
all others
V
Full scale span7
4.9
9.9
5
10
5.1
10.1
KTx6N...
all others
Ω
Output impedance
25
5
Current consumption (no load)
3
mA
0.5...4.5 V output (VS = 15 V, RL > 100 kΩ, tamb = 25°C)
Characteristics
Min.
Typ.
Max.
Unit
Zero pressure offset
KTx6N...
all others
2.450
0.450
2.5
0.5
2.550
0.550
V
Full scale span7
KTx6N...
all others
1.950
3.950
2
4
2.050
4.050
Ω
Output impedance
25
5
Current consumption (no load)
3
mA
0...5 V output (VS = 15 V, RL > 100 kΩ, tamb = 25°C)
Characteristics
Min.
Typ.
Max.
Unit
Zero pressure offset
KTx6N...
all others
2.45
2.5
0.03
2.55
0.08
V
Full scale span7
KTx6N...
all others
2.45
4.95
2.5
5.0
2.55
5.05
Ω
Output impedance
25
5
Current consumption (no load)
3
mA
4...20 mA output (VS = 15 V, RL = 100 Ω, tamb = 25°C)
Characteristics
Min.
Typ.
Max.
Unit
mA
Zero pressure offset
KTx6N...
all others
11.9
3.9
12.0
4.0
12.1
4.1
Full scale span7
KTx6N...
all others
7.9
15.9
8.0
16.0
8.1
16.1
Power consumption (IL = 20 mA)
250
mW
December 2008 / 550
3/6
www.sensortechnics.com
KTE6000 / KTU6000 Series
OEM pressure transmitters for industrial media
OUTPUT CHARACTERISTICS
0...10 V output version
0.5...4.5 V output version
10
10
Vout
V
9
Vout
V
9
8
7
6
5
4
3
2
1
8
7
KTx6N...
6
5
4
3
2
1
KTx6N...
KTx6P...
KTx6P...
all other
all other
-100 -80 -60 -40 -20 0 +20 +40 +60 +80+100%
operating pressure
-100 -80 -60 -40 -20 0 +20 +40 +60 +80+100%
operating pressure
0...5 V output version
4...20 mA output version
20
10
9
8
7
6
5
4
3
2
1
Vout
V
Iout 18
mA
16
14
KTx6P...
12
KTx6N...
10
8
KTx6N...
KTx6P...
all other
6
all other
4
2
-100 -80 -60 -40 -20 0 +20 +40 +60 +80+100%
operating pressure
-100 -80 -60 -40 -20
0
+20 +40 +60 +80+100%
operating pressure
RECOMMENDED ACCESSORY
LOAD LIMITATION
4...20 mA output version
Plug DINEN175301-803A and profile washer included
in delivery. For a complete connector/cable assembly
use order no. ZK000110-x (x=cable lenghts in m).
1400
Ohm
1200
50
1000
800
600
400
200
34
Profile washer
M3
dimensions in mm
31
0
5
16 20
25 30 V
9
Note:
supply voltage
For proper function of all gage devices the
gage port must be vented to the atmosphere
through the connector/cable assembly.
December 2008 / 550
4/6
www.sensortechnics.com
KTE6000 / KTU6000 Series
OEM pressure transmitters for industrial media
OUTLINE DRAWING
KTE6...T
23 (0.90)
NOM 68 (2.68)
17
(0.67)
4.5
(0.18)
12
(0.47)
vent hole
3
8.5 (0.33)
1
2
KTE6...Q
NOM 68 (2.86)
8.5 (0.33)
12
(0.47)
4.5
(0.18)
12
(0.47)
vent hole
3
1
2
KTE6...L
NOM 68 (2.68)
8.5 (0.33)
17
(0.67)
4.5
(0.18)
vent hole
3
12
(0.47)
1
2
KTE6...O (flush mount)
NOM 68 (2.68)
8.5 (0.33)
13
(0.51)
12
(0.47)
vent hole
3
12
(0.47)
1
2
mass: 210 g
dimensions in mm (inches)
December 2008 / 550
5/6
www.sensortechnics.com
KTE6000 / KTU6000 Series
OEM pressure transmitters for industrial media
ELECTROMAGNETIC CAPABILITY8
Test conditions
Criterion Interference
Radiated, radio frequency electromagnetic
field immunity (RFI)
EN61000-4-3: Grade 3, 10 V/m, 80 to 1000 MHz
80 % AMC (1 kHz)
A
<1 %FSO
EN61000-4-4:
Electrical fast transient / burst immunity (EFT)
Electrostatic discharge immunity test (ESD)
Grade 3, ±2 kV
B
B
<1 %FSO
<1 %FSO
EN61000-4-2:
Grade 4, ±8 kV, contact discharge
Immunity to conducted disturbances induced EN61000-4-6: Grade 3, 0.15 to 80 MHz
A
<1 %FSO
by radio-frequency fields
10 V, 80 % AMC (1 kHz)
Specification notes:
IP 65 protection is given when the connector is locked with a rubber washer. For proper function the gage port is vented to
the atmosphere through the connector/cable assembly. Thus the cable end must have access to the ambient pressure.
The minimum supply voltage is directly proportional to the load resistance seen by the transmitter. For more details see the
load limitation diagram.
1.
2.
Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element.
Thermal effects tested and guaranteed from 0 to 70°C relative to 25°C. All specifications shown are relative to 25°C.
Non-linearity refers to the Best Straight Line fit measured for offset, full scale span and 1/2 full scale span.
Long term stability is the change in output after one year or 1 million pressure cycles.
Span is the arithmetic difference in transmitter output signal measured at zero pressure and the maximum operating pressure.
Test are in accordance with EN61000-6-2, April 1999.
3.
4.
5.
6.
7.
8.
Other sealing materials on special request.
9.
Other fittings on special request.
CE-labelling is in accordance with 89/336/EEC.
The pressure transmitters must not be used as safety accessories according to article 1, 2.1.3 of the directive 97/23/EC.
10.
11.
12.
ORDERING INFORMATION
KTx6
xxx
x
x
x
E: bar calibration
U: psi calibration
Output signal
0:
4:
6:
7:
0...10 V
4...20 mA
0.5...4.5 V
0...5 V
KTE6000 series
001: 0 to 1 bar
N01: -1 to +1 bar
P01: -1 to 0 bar
KTU6000 series
015: 0 to 15 psi
N15: -15 to +15 psi
P15: -15 to 0 psi
Fitting size10
L: 1/4" NPT male
O: G 3/4" (3/4"BSP)
only up to 16 bar/200 psi
Q: G 1/4" (1/4" BSP) male
T: G 1/2" (1/2" BSP)
002:
005:
010:
016:
020:
025:
035:
050:
070:
100:
150:
200:
300:
400:
0 to 2 bar
0 to 5 bar
030:
050:
100:
200:
300:
500:
0 to 30 psi
0 to 50 psi
0 to 100 psi
0 to 200 psi
0 to 300 psi
0 to 500 psi
0 to 10 bar
0 to 16 bar
0 to 20 bar
0 to 25 bar
0 to 35 bar
0 to 50 bar
0 to 70 bar
0 to 100 bar
0 to 150 bar
0 to 200 bar
0 to 300 bar
0 to 400 bar
1K0: 0 to 1000 psi
1K5: 0 to 1500 psi
2K0: 0 to 2000 psi
3K0: 0 to 3000 psi
4K5: 0 to 4500 psi
6K0: 0 to 6000 psi
Pressure mode
G: gage pressure1
(up to 50 bar/750 psi)
S: sealed gage
(above 50 bar/750 psi
A: absolute pressure
(up to 50 bar/750 psi)
Note: Other pressure ranges and options are widely available.
Please contact your nearest Sensortechnics sales representative.
Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the
application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.
December 2008 / 550
6/6
www.sensortechnics.com
相关型号:
©2020 ICPDF网 联系我们和版权申明