PTE005D4C [SENSORTECHNICS]

Precision differential pressure transmitters;
PTE005D4C
型号: PTE005D4C
厂家: SENSORTECHNICS GMBH    SENSORTECHNICS GMBH
描述:

Precision differential pressure transmitters

文件: 总5页 (文件大小:118K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
BTE5000 / PTE5000 / PTU5000 Series  
Precision differential pressure transmitters  
FEATURES  
· 25 mbar to 10 bar, 0.3 to 150 psi  
differential pressure  
· 1...6 V or 4...20 mA output12  
· Precision temperature compensated  
and calibrated  
· Rugged aluminium housing  
· Female 1/8" BSP and 1/8" NPT fittings  
MEDIA COMPATIBILITY  
Pressure inlet:  
Non-corrosive, non-ionic media such as air, dry gases  
and the like  
Housing:  
Aluminium, protection class IP 67 (according to  
DIN EN 60529, NEMA 6)1  
SPECIFICATIONS10,11  
ELECTRICAL CONNECTION  
Maximum ratings  
1...6 V output version  
Supply voltage  
12...32 V  
1
+Vs  
12 to 32 V  
Output current BTE(M)/PTE/PTU5...D1...  
Source  
Sink  
20 mA  
10 mA  
2
Vout  
Sensor  
V
4
3
GND  
Output current BTE(M)/PTE/PTU5...D4...  
30 mA  
-Vs  
Temperature limits  
Storage  
Operating  
case  
-40...85 °C  
-25...85 °C  
0...70°C  
Compensated  
4...20 mA output version  
Proof pressure2  
BTEM5x025... / PTx5000.3...  
BTEM5x070..., BTEM5x350... /  
PTx5001..., PTx5005...  
all others  
0.35 bar / 5 psi  
1.4 bar / 20 psi  
1
+Vs  
12 to 32 V  
GND  
Sensor  
2 x rated pressure  
V
RL  
4
Pressure at any port3  
BTEM5x025... / PTx5000.3...  
all others  
-Vs  
3.5 bar / 50 psi  
12 bar / 175 psi  
3
case  
E / 11101 / B  
1/5  
www.first-sensor.com  
www.sensortechnics.com  
BTE5000 / PTE5000 / PTU5000 Series  
Precision differential pressure transmitters  
COMMON PERFORMANCE CHARACTERISTICS8  
Characteristics  
Min.  
Typ.  
Max.  
Unit  
Thermal effects  
(0 to 70°C)6  
Offset all 70 mbar / 1 psid devices  
±0.025 ±0.125  
±0.008 ±0.040  
±0.005 ±0.025  
±0.001 ±0.045  
all 350 mbar / 5 psid devices  
all others  
Span  
%FSO/°C  
Non-linearity and hysteresis4  
Long term stability5  
±0.2  
±0.2  
0.04  
1
±1  
%FSO  
ms  
Output noise (0 f 1 kHz)  
Response time (10 to 90 %)  
INDIVIDUAL PERFORMANCE CHARACTERISTICS8  
1...6 V output versions (VS = 15 V, tamb = 25°C, RL > 100 k, com. mode pressure = 0)  
Characteristics  
Min.  
Typ.  
Max.  
Unit  
Zero pressure offset  
Full scale span7  
BTE(M)5P... / PTx5P...  
all others  
3.4  
0.9  
3.5  
1.0  
3.6  
1.1  
BTE(M)5P... / PTx5P...  
all others  
2.4  
4.9  
2.5  
5.0  
2.6  
5.1  
V
6.0  
Full scale output  
Power supply rejection  
Offset  
Span  
0.05  
0.03  
%FSO/V  
Output impedance  
Power consumption  
50  
60  
mW  
4...20 mA output versions (VS = 15 V, tamb = 25°C, RL = 100 , com. mode pressure = 0)  
Characteristics  
Min.  
Typ.  
Max.  
Unit  
Zero pressure offset  
Full scale span7  
BTE(M)5P... / PTx5P...  
all others  
11.9  
3.9  
12.0  
4.0  
12.1  
4.1  
BTE(M)5P... / PTx5P...  
all others  
7.9  
15.9  
8.0  
16.0  
8.1  
16.1  
mA  
20.0  
Full scale output  
Power supply rejection  
Offset  
Span  
0.05  
0.03  
%FSO/V  
Output impedance  
0.1  
Power consumption (IL = 20 mA)  
260  
mW  
E / 11101 / B  
2/5  
www.first-sensor.com  
www.sensortechnics.com  
BTE5000 / PTE5000 / PTU5000 Series  
Precision differential pressure transmitters  
LOAD LIMITATION  
4...20 mA output versions  
1200  
Ohm  
1000  
800  
600  
400  
200  
operating  
range  
0
10  
20  
30  
V
Vsupply  
ELECTROMAGNETIC CAPABILITY9  
Test conditions  
Criterion Interference  
Radiated, radio frequency  
electromagnetic field immunity (RFI)  
EN61000-4-3: 10 V/m, 80 to 1000 MHz  
80 % AMC (1 kHz)  
A
B
B
A
<1 %FSO  
<1 %FSO  
<1 %FSO  
<1 %FSO  
Electrical fast transient /  
burst immunity (EFT)  
EN61000-4-4: ±2 kV  
Electrostatic discharge immunity  
test (ESD)  
EN61000-4-2: ±4 kV, contact discharge  
±8 kV, air discharge  
Immunity to conducted disturbances EN61000-4-6: 0.15 to 80 MHz  
induced by radio-frequency fields  
10 V, 80 % AMC (1 kHz)  
Specification notes:  
1. IP 67 protection for BTE(M)5...A / PTx5...A is given with locked connector only.  
2. Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element.  
3. This is the highest pressure which can be applied to any port at any time. At the same time the differential pressure between  
the ports H and L must not exceed the maximum proof pressure.  
4. Non-linearity refers to the Best Straight Line fit measured for offset, full scale span and 1/2 full scale span.  
5. Long term stability is the change in output after one year or 1 million pressure cycles.  
6. Thermal effects tested and guaranteed from 0 - 70 °C relative to 25°. All specifications shown are relative to 25°C.  
7. Full scale span is the algebraic difference between the positive full scale output and zero pressure offset.  
8. Higher pressure applied to port H.  
9. Test are in accordance with EN 61000-6-2.  
10. CE-labelling is in accordance with 2004/108/EC.  
11. The pressure transmitters must not be used as safety accessories according to article 1, 2.1.3 of the directive 97/23/EC.  
12. 0...10 V square rooting output signal on special request.  
E / 11101 / B  
3/5  
www.first-sensor.com  
www.sensortechnics.com  
BTE5000 / PTE5000 / PTU5000 Series  
Precision differential pressure transmitters  
OUTLINE DRAWING  
Connector version  
NOM 86.0 (3.39)  
40.0  
(1.58)  
72.0 (2.84)  
H: high pressure port  
L: low pressure port  
20.0  
(0.79)  
13.5 diam. (0.53)  
mating plug  
8.0 (0.31) min.  
4
M12 x 1  
(0.47)  
1
3
2
8.0 (0.31) min.  
2 x M5  
(UNC 10-24)  
9.0  
(0.35)  
BTE.../PTE...: 2 x 1/8" BSP  
PTU...: 2 x 1/8" NPT  
ELECTRICAL CONNECTION  
Connection  
dimensions in mm  
(inches)  
mass: typ. 170 g  
1 - 6 V  
output  
4 - 20 mA  
output  
Pin  
1
2
3
4
+Vs  
Vout  
case  
-Vs  
+Vs  
NC  
case  
-Vs  
Cable version  
40.0  
(1.58)  
90.0 (3.54)  
72.0 (2.84)  
H: high pressure port  
L: low pressure port  
20.0  
(0.79)  
13.5 diam. (0.53)  
1 m (3.3 ft) shielded cable  
4 x 0.25 mm² (AWG24)  
8.0 (0.31) min.  
8.0 (0.31) min.  
9.0  
(0.35)  
2 x M5  
(UNC 10-24)  
BTE.../PTE...: 2 x 1/8" BSP  
PTU...: 2 x 1/8" NPT  
ELECTRICAL CONNECTION  
Connection  
dimensions in mm  
(inches)  
mass: typ. 220 g  
1 - 6 V  
output  
4 - 20 mA  
output  
bare case/shield case/shield  
brown  
white  
+Vs  
NC  
+Vs  
NC  
green  
yellow  
Vout  
-Vs  
NC  
-Vs  
E / 11101 / B  
4/5  
www.first-sensor.com  
www.sensortechnics.com  
BTE5000 / PTE5000 / PTU5000 Series  
Precision differential pressure transmitters  
RECOMMENDED CABLE/CONNECTOR ACCESSORY  
for connector version  
Order number ZK000101, other cable length on special request  
NOM 2 m  
PIN CONNECTION  
Pin  
Flying lead end  
1
2
3
4
brown  
green  
white + shield  
yellow  
NOM  
60  
Included in delivery!  
M12 x 1  
Ø 20  
ORDERING INFORMATION  
BT/PT  
x
(M)  
5xxx  
D
x
x
Calibration  
Electrical connection  
BT: calibration in mbar/bar  
PT: calibration in psi  
A: connector version  
C: cable version  
Pressure connection  
E: 1/8" BSP female  
U: 1/8" NPT female  
Output signal  
1: 1...6 V  
4: 4...20 mA  
For mbar ranges only  
Differential pressure  
Pressure range  
BTE5000 series  
PTE/PTU5000 series  
0025:  
P025:  
0070:  
P070:  
0350:  
0...25 mbar  
-25...+25 mbar  
0...70 mbar  
-70...+70 mbar  
0...350 mbar  
000.3:  
001:  
P01:  
005:  
P05:  
015:  
0...0.3 psi  
0...1 psi  
-1...+1 psi  
0...5 psi  
-5...+5 psi  
0...15 psi  
P350: -350...+350 mbar  
001:  
P01:  
002:  
005:  
010:  
0...1 bar  
-1...+1 bar  
0...2 bar  
0...5 bar  
0...10 bar  
P15: -15...+15 psi  
030:  
100:  
150:  
0...30 psi  
0...100 psi  
0...150 psi  
Other pressure ranges and options are widely available. Please contact First Sensor.  
First Sensor reserves the right to make changes to any products herein. First Sensor does not assume any liability arising out of the application  
or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.  
E / 11101 / B  
5/5  
www.first-sensor.com  
www.sensortechnics.com  

相关型号:

PTE0070D1A

Precision differential pressure transmitters
SENSORTECHNIC

PTE0070D1C

Precision differential pressure transmitters
SENSORTECHNIC

PTE0070D4A

Precision differential pressure transmitters
SENSORTECHNIC

PTE0070D4C

Precision differential pressure transmitters
SENSORTECHNIC

PTE010D1A

Precision differential pressure transmitters
SENSORTECHNIC

PTE010D1C

Precision differential pressure transmitters
SENSORTECHNIC

PTE010D4A

Precision differential pressure transmitters
SENSORTECHNIC

PTE010D4C

Precision differential pressure transmitters
SENSORTECHNIC

PTE0350D1A

Precision differential pressure transmitters
SENSORTECHNIC

PTE0350D1C

Precision differential pressure transmitters
SENSORTECHNIC

PTE0350D4A

Precision differential pressure transmitters
SENSORTECHNIC

PTE0350D4C

Precision differential pressure transmitters
SENSORTECHNIC