RPUM250G6A [SENSORTECHNICS]

Basic pressure sensors; 基本压力传感器
RPUM250G6A
型号: RPUM250G6A
厂家: SENSORTECHNICS GMBH    SENSORTECHNICS GMBH
描述:

Basic pressure sensors
基本压力传感器

传感器 压力传感器
文件: 总5页 (文件大小:219K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
RPU Series  
Basic pressure sensors  
FEATURES  
· 0...35 mbar to 0...16 bar and  
0...0.5 to 0...250 psi gage or differential  
· High impedance bridge  
· Miniature package  
· Different pinning configurations  
· Usable for wet/wet applications8  
· Sensortechnics PRO services  
MEDIA COMPATIBILITY  
All media compatible with  
port 1: - polyetherimide  
- silver-filled silicone  
- silicon nitride  
port 29: - polyetherimide  
- fluor-silicone  
- silicon  
ELECTRICAL CONNECTION  
SPECIFICATIONS  
Maximum ratings  
Supply voltage  
12 V  
+Vs  
1
Temperature limits  
Storage  
-55 to +100°C  
-40 to +85°C  
Operating  
4
-
Lead temperature (10 sec. soldering)  
Humidity limits  
300°C  
0...100 %RH  
20 g sine  
Output  
2
+
Vibration (0 to 2000 Hz)  
(qualification tested)  
3
Mechanical shock  
150 g  
(qualification tested)  
E / 11702 / A  
1/5  
www.sensortechnics.com  
RPU Series  
Basic pressure sensors  
PRESSURE SENSOR CHARACTERISTICS  
(Vs = 10.0 ± 0.01 V, tamb = 25 °C)  
Full-scale span2  
Part number  
Operating pressure Proof pressure1  
Min.  
Typ.  
Max.  
46 mV  
RPUM035...  
RPUM050...  
RPUM100...  
RPUM250...  
RPUB001...  
RPUB002...  
RPUB005...  
RPUB010...  
RPUB016...  
RPUP0x5...  
RPUP001...  
RPUP005...  
RPUP015...  
RPUP030...  
RPUP100...  
RPUP250...  
0...35 mbar  
0...50 mbar  
0...100 mbar  
0...250 mbar  
0...1 bar  
1.4 bar  
1.4 bar  
1.4 bar  
1.4 bar  
3 bar  
24 mV  
21 mV  
44 mV  
61 mV  
159 mV  
232 mV  
113 mV  
84 mV  
134 mV  
24 mV  
30 mV  
85 mV  
165 mV  
240 mV  
156 mV  
145 mV  
35 mV  
33 mV  
44 mV  
66 mV  
88 mV  
83 mV  
105 mV  
276 mV  
410 mV  
215 mV  
163 mV  
260 mV  
46 mV  
218 mV  
320 mV  
163 mV  
123 mV  
197 mV  
35 mV  
0...2 bar  
4 bar  
0...5 bar  
12 bar  
35 bar  
35 bar  
20 psi  
20 psi  
20 psi  
45 psi  
60 psi  
200 psi  
500 psi  
0...10 bar  
0...16 bar  
0...0.5 psi  
0...1 psi  
45 mV  
60 mV  
0...5 psi  
115 mV  
225 mV  
330 mV  
225 mV  
212 mV  
145 mV  
285 mV  
420 mV  
294 mV  
280 mV  
0...15 psi  
0...30 psi  
0...100 psi  
0...250 psi  
PERFORMANCE CHARACTERISTICS  
(Vs = 10.0 ± 0.01 V, tamb = 25 °C)  
Characteristics  
Zero pressure offset  
Temperature effects (0 to 50 °C)4  
Min.  
-20  
Typ.  
Max.  
+20  
Unit  
mV  
Offset  
Span  
±2.0  
-2000  
+2200  
±0.25  
±0.15  
±0.5  
ppm/°C  
% span  
Temperature effects on bridge impedance4  
Non-linearity (BSL)3  
Repeatability and hysteresis5  
Long term stability7  
±1.0  
Input impedance  
4.0  
4.0  
5.0  
6.0  
6.0  
1.0  
k  
Output impedance  
Response time6  
5.0  
ms  
E / 11702 / A  
2/5  
www.sensortechnics.com  
RPU Series  
Basic pressure sensors  
OUTLINE DRAWINGS10  
RPU...G6A (single inline pinning, 1 x 4), gage pressure devices  
12,7  
Ø 6,4  
Ø 5,1  
Ø 1,93  
PIN 1  
Ø 1,27  
3 x 2,54  
2,29  
4 x 1,02  
P2  
third angle projection  
dimensions in mm  
4
3 2 1  
mass: 2 g  
12,7  
RPU...G2A (dual inline pinning, 2 x 2), gage pressure devices  
12,7  
PIN 3  
PIN 4  
Ø 6,4  
Ø 5,1  
Ø 1,93  
Ø 1,27  
PIN 1  
PIN 2  
P2  
4 x 0,5  
4 x 1,02  
4 x 0,41  
third angle projection  
dimensions in mm  
5,1  
8,4  
12,7  
mass: 2 g  
E / 11702 / A  
3/5  
www.sensortechnics.com  
RPU Series  
Basic pressure sensors  
OUTLINE DRAWINGS10  
RPU...D6A (single inline pinning, 1 x 4), differential pressure devices  
12,7  
Ø 6,4  
Ø 5,1  
Ø 1,93  
PIN 1  
Ø 1,27  
3 x 2,54  
2,29  
4 x 1,02  
P2  
4
3
2
1
third angle projection  
dimensions in mm  
P1  
mass: 2 g  
12,7  
Specification notes:  
1. The maximum specified pressure which may be applied to the sensor without causing a permanent change in the output  
characteristics.  
2. Span is the algebraic difference between the output voltage at full-scale pressure and the output at zero pressure. Span is  
ratiometric to the supply voltage.  
3. Non-linearity refers to the Best Straight Line fit, measured for offset pressure, full scale pressure and 1/2 full scale pressure.  
4. Error band of the offset voltage, span or bridge impedance in the specified temperature range, relative to the 25°C reading.  
5. Repeatability, the deviation in output readings for successive application of any given input pressure (all other conditions  
remaining constant). Hysteresis, the error defined by the deviation in output signal obtained when a specific pressure point is  
approached first with increasing pressure, then with decreasing pressure or vice versa (all other conditions remaining constant).  
6. Response time for 0 to full-scale pressure step change, readings taken at 10 % and 90 % of full-scale pressure.  
7. Long term stability of offset and span over a period over one year.  
8. The sensors might be used on both ports for media compatible with the components specified under "Media Compatibility".  
9. Other sealing materials are available on request. Minimum order quantities might be required.  
10. Other pressure port styles, like barbed ones, luers, modular, M5, needle style or flow through connection, are  
available on request. Minimum order quantities might be required.  
E / 11702 / A  
4/5  
www.sensortechnics.com  
RPU Series  
Basic pressure sensors  
ORDERING INFORMATION - AVAILABLE LISTINGS  
Note:  
Preferred listings are highlighted in grey  
Gage pressure  
Dual inline pinning  
Differential pressure  
Pressure range  
Single inline pinning  
RPUM035G6A  
RPUM050G6A  
RPUM100G6A  
RPUM250G6A  
RPUB001G6A  
RPUB002G6A  
RPUB005G6A  
RPUB010G6A  
RPUB016G6A  
RPUP0x5G6A  
RPUP001G6A  
RPUP005G6A  
RPUP015G6A  
RPUP030G6A  
-
Single inline pinning  
RPUM035D6A  
RPUM050D6A  
RPUM100D6A  
RPUM250D6A  
RPUB001D6A  
RPUB002D6A  
RPUB005D6A  
RPUB010D6A  
RPUB016D6A  
RPUP0x5D6A  
RPUP001D6A  
RPUP005D6A  
RPUP015D6A  
RPUP030D6A  
-
35 mbar  
50 mbar  
100 mbar  
250 mbar  
1 bar  
-
RPUM050G2A  
RPUM100G2A  
RPUM250G2A  
RPUB001G2A  
RPUB002G2A  
RPUB005G2A  
RPUB010G2A  
RPUB016G2A  
-
2 bar  
5 bar  
10 bar  
16 bar  
0.5 psi  
1 psi  
RPUP001G2A  
RPUP005G2A  
RPUP015G2A  
RPUP030G2A  
-
5 psi  
15 psi  
30 psi  
60 psi  
100 psi  
250 psi  
RPUP100G6A  
RPUP250G6A  
RPUP100G2A  
RPUP250G2A  
RPUP100D6A  
RPUP250D6A  
Sensortechnics PRO services:  
· Extended guarantee period of 2 years  
· Improved performance characteristics  
· Custom product modifications and adaptations even for small quantities  
· Advanced logistics models for supply inventory and short delivery times  
· Technical support through application engineers on the phone or at your site  
· Fastest possible technical response for design and QA engineers  
... plus other services on request  
Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the  
application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.  
E / 11702 / A  
5/5  
www.sensortechnics.com  

相关型号:

RPUM250G6B

Pressure sensors with special fittings
SENSORTECHNIC

RPUP001D6A

Basic pressure sensors
SENSORTECHNIC

RPUP001G2A

Basic pressure sensors
SENSORTECHNIC

RPUP001G2B

Pressure sensors with special fittings
SENSORTECHNIC

RPUP001G6A

Basic pressure sensors
SENSORTECHNIC

RPUP001G6B

Pressure sensors with special fittings
SENSORTECHNIC

RPUP005D6A

Basic pressure sensors
SENSORTECHNIC

RPUP005G2A

Basic pressure sensors
SENSORTECHNIC

RPUP005G2B

Pressure sensors with special fittings
SENSORTECHNIC

RPUP005G6A

Basic pressure sensors
SENSORTECHNIC

RPUP005G6B

Pressure sensors with special fittings
SENSORTECHNIC

RPUP015D6A

Basic pressure sensors
SENSORTECHNIC