1062966 [SICK]
PRESSURE SENSORS;PAC50-DCC
PAC50
PRESSURE SENSORS
PAC50-DCC | PAC50
PRESSURE SENSORS
Ordering information
A
B
C
D
E
F
Type
Part no.
PAC50-DCC
1062991
Other models and accessories www.sick.com/PAC50
Illustration may differ
Detailed technical data
Features
Dry compressed air
Gauge pressure
0 bar ... 10 bar
0 °C ... +60 °C
Medium
H
I
Pressure type
Measuring range
Process temperature
Analog signal output and ohmic load RA
Optional, 4 mA ... 20 mA / 0 V… 10 V. Automatic detection depending on connected load or
programmable. Output signals can be inverted: 20 mA ... 4 mA / 10 V ... 0 V
Load resistance for current output < 600 Ohm
J
Load resistance with current output > 3 kOhm
Max. + 5 % of span
Zero point adjustment
Output signal
K
L
2 x PNP/NPN/Push-Pull + 4 mA ... 20 mA / 0 V ... 10 V
Switching output 2 can be set as diagnostics output
Diagnostics output
Display
LCD with LED backlight (green/red), can be rotated electronically by 180°
Pressure display: 4 digits, 16 segments
Pressure unit in display can be switched: bar, MPa, kPa, psi and inHg
Update: 1,000, 500, 200, 100 ms (adjustable)
M
N
O
P
Q
R
S
T
300 ms
Initialization time
Performance
Non-linearity
Accuracy
≤ ± 0.5 %, of span (Best Fit Straight Line, BFSL) according to IEC 61298-2
≤ ± 1.5 % of the span including non-linearity, hysteresis, zero point and full scale error (corre-
sponds to error of measurement as per IEC 61298-2)
≤ ± 0.2 % of span
≤ ± 0.2 % of the span
+10 °C ... +60 °C
Setting accuracy of switching outputs
Non-repeatability
Rated temperature range
Mechanics/electronics
1)
Process connection
PIF 4 mm + G ¼
Housing: polycarbonate, Buttons: TPE, DIN rail mounting: POM, seals: NBR
Housing material
1)
Bottom side: push-in fitting for 4 mm pneumatic hose, back side: thread G ¼ female according to DIN ISO 16030.
When plugged in with a suitable mating connector.
2)
2
FLUID SENSORS | SICK
Online data sheet | 2016-03-19 00:51:29
Subject to change without notice
PAC50-DCC | PAC50
PRESSURE SENSORS
17 V DC ... 30 V DC
Supply voltage
Max. 40 mA at L+ = 24 VDC
Power consumption
Protection class: III
Electrical safety
Overvoltage protection: 32 V DC
Short-circuit protection: QA, Q1, Q2 towards M and L+
Reverse polarity protection: L+ to M
EMC directive: 2004/108/EC, EN 61326-2-3
Approx. 40 g
CE-conformity
Weight sensor
Enclosure rating
IP 65 / IP 67 (according to IEC 60529) 2)
✔
✔
✔
Protection class III
RoHS certificate
CRUus certificate
1)
Bottom side: push-in fitting for 4 mm pneumatic hose, back side: thread G ¼ female according to DIN ISO 16030.
When plugged in with a suitable mating connector.
2)
Ambient data
0 °C ... +60 °C
–20 °C ... +80 °C
≤ 90 %
Ambient temperature
Storage temperature
Relative humidity
Shock load
Max. 30 g, xyz according to IEC 60068-2-27 (11 ms, mechanical shock)
Max. 5 g (10 ... 150 Hz), xyz, to DIN EN 60068-2-6
Vibration load
Dimensional drawing (Dimensions in mm (inch))
Bottom side: push-in fitting for 4 mm pneumatic hose, back side: thread G ¼ female
13.6
(0.54)
M12x1
9.5
(0.37)
35
(1.38)
Push-in fitting
ø 4.0 (ø 0.16)
2016-03-19 00:51:29 | Online data sheet
Subject to change without notice
FLUID SENSORS | SICK
3
PAC50-DCC | PAC50
PRESSURE SENSORS
Connection type
A
B
C
D
E
F
Round connector M12 x 1, 5-pin
3
4
5
2
1
Output signals
Type code
PAC50-xxC
Electrical
Pin assignment
connection
2 x digital + analog
M12 x 1, 5 pins
L+ = 1, M = 3, Q1 = 4, Q2 = 2, QA = 5
① L+: Positive supply connection
② M: Negative supply connection
③ Q1: Switching output 1
④ C/Q1: With IO-Link: Communication/ switching output 1
⑤ Q2: Switching output 2
⑥ QA: Analog output
Instruction for installation
H
I
d
J
4
K
L
d
3
d
2
M
N
O
P
Q
R
S
T
a
1
Recommended accessories
Other models and accessories www.sick.com/PAC50
Brief description
Type
Part no.
Mounting brackets and mounting plates
Wall-mounting kit; mounting element for wall-mounting of pressure switch PAC50,
Mounting element: polycarbonate, screws: steel, zinc-coated
BEF-MA-WLM-
NTS-PAC5
2069198
Terminal and alignment brackets
4
FLUID SENSORS | SICK
Online data sheet | 2016-03-19 00:51:29
Subject to change without notice
PAC50-DCC | PAC50
PRESSURE SENSORS
Brief description
Type
Part no.
Switch panel installation kit, for installation of the PAC50 pressure switch in a switch
panel. Maximum thickness of switch panel 5 mm., Panel-mounting frame and mounting
element: polycarbonate, screws: steel, zinc-coated
BEF-MA-
CTRLPS-PAC5
2069200
2016-03-19 00:51:29 | Online data sheet
Subject to change without notice
FLUID SENSORS | SICK
5
相关型号:
©2020 ICPDF网 联系我们和版权申明