1068410 [SICK]
SAFETY LIGHT CURTAINS;型号: | 1068410 |
厂家: | SICK AG |
描述: | SAFETY LIGHT CURTAINS |
文件: | 总7页 (文件大小:1053K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
EXS-09D6403B020, EXE-09D6403B020
deTec4 Core Ex
SAFETY LIGHT CURTAINS
EXS-09D6403B020, EXE-09D6403B020 | deTec4 Core Ex
SAFETY LIGHT CURTAINS
Ordering information
A
B
C
D
E
F
System part
Sender
Type
Part no.
1068410
1068409
EXS-09D6403B020
EXE-09D6403B020
Receiver
Included with delivery with every device: 1 system connecting cable with flying leads 30 m in length.
Other models and accessories www.sick.com/deTec4_Core_Ex
Detailed technical data
Features
H
I
Sender/receiver pair in explosion-proof enclosure
System part
30 mm
Resolution
900 mm
Protective field height
Scanning range
Response time
Synchronization
0 m ... 8 m
11 ms
J
Optical synchronisation
K
L
Safety-related parameters
Type 4 (IEC 61496)
Type
SIL3 (IEC 61508)
SILCL3 (EN 62061)
Safety integrity level
Category 4 (EN ISO 13849)
PL e (EN ISO 13849)
Category
M
N
O
P
Q
R
S
T
Performance level
3,7 x 10-9 (EN ISO 13849)
PFHD (mean probability of a dangerous fail-
ure per hour)
20 years (EN ISO 13849)
TM (mission time)
At least one OSSD is in the OFF state.
Safe state in the event of a fault
Interfaces
System connection
Connection type Male connector M12, 5-pin
Permitted cable length ≤ 50 m
LEDs
Status display
Fieldbus, industrial network
Integration via Flexi Soft safety controller
CANopen, DeviceNet, EtherCAT, EtherNet/IP, Modbus TCP, PROFIBUS DP, PROFINET 1)
1)
For further information on Flexi Soft, please see sens:Control – safe control solutions product catalog or -> www.sick.com/FlexiSoft.
2
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK
Online data sheet | 2016-07-04 20:20:08
Subject to change without notice
EXS-09D6403B020, EXE-09D6403B020 | deTec4 Core Ex
SAFETY LIGHT CURTAINS
Electrical data
III (EN 50178)
Protection class
Supply voltage VS
Ripple
24 V DC (19.2 V DC ... 28.8 V DC)
≤ 10 % 1)
2.02 W (DC) / 1.01 W (DC)ꢀ(depending on type)
Power consumption typical
Safety outputs (OSSD)
2 PNP semiconductors, short-circuit protected, cross-circuit monitored 2)
Type of output
Switching voltage HIGH 24 V DC (VS – 2.25 V DC ... VS)
Switching voltage LOW ≤ 2 V DC
Switching current ≤ 300 mA
1)
2)
Within the limits of V .
S
Applies to the voltage range between –30 V and +30 V.
Mechanical data
161.8 mm x 142.1 mm
Housing cross-section (incl. system connec-
tion)
36.051 kg (± 50 g)
36.041 kg (± 50 g)
(depending on type)
Weight
Ambient data
IP 66 (EN 60529)
Enclosure rating
–20 °C ... +55 °C
Ambient operating temperature
Storage temperature
Air humidity
–30 °C ... +70 °C
15 % ... 95 %, Non-condensing
5 g, 10 Hz ... 55 Hz (EN 60068-2-6)
10 g, 16 ms (EN 60068-2-29)
Vibration resistance
Shock resistance
Other information
850 nm
Wave length
2016-07-04 20:20:08 | Online data sheet
Subject to change without notice
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK
3
EXS-09D6403B020, EXE-09D6403B020 | deTec4 Core Ex
SAFETY LIGHT CURTAINS
Dimensional drawing (Dimensions in mm (inch))
deTec4 Core Ex, 900 mm
A
B
C
D
E
F
161.8
(6.37)
58.7
(2.31)
67.5
(2.66)
89.6
(3.53)
9.5
(0.37)
44.5
(1.75)
6.4
(0.25)
H
I
J
K
L
142.1
(5.59)
M
N
O
P
Q
R
S
T
4
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK
Online data sheet | 2016-07-04 20:20:08
Subject to change without notice
EXS-09D6403B020, EXE-09D6403B020 | deTec4 Core Ex
SAFETY LIGHT CURTAINS
Connection diagram
deTec4 Core safety light curtain connected to UE48-2OS safety relay
24 V DC
1
2
3
4
5
1
2
3
4
5
+24V
n.c.
+24V
OSSD1
GND
GND
n.c.
OSSD2
n.c.
n.c.
S1
S33 S11 S12 S31 A1 13 23 31
k1
k2
UE48-2OS2D2
S34 S35 S21 S22 A2 14 24 32
K1
K2
0 V DC
E114585/01/2014-05-08
Task
Connection of a deTec4 Core safety light curtain to UE48-2OS.
Operating mode: with restart interlock and external device monitoring.
Function
When the light path is clear, the OSSD1 and OSSD2 outputs are live. The system is ready to switch on if K1 and K2 are de-ener-
gized. By pressing S1 (button is pressed and released), the UE48-2OS is energized and its 13 - 14 and 23 - 24 contacts activate K1
and K2. On interruption of one of the light beams, the UE48-2OS is de-energized by the OSSD1 and OSSD2 outputs and K1 and K2
are deactivated.
Fault analysis
OSSD cross-circuits and short-circuits are detected and lead to the inhibited state (lock-out). The incorrect functioning of one of the
K1 or K2 contactors will be detected and does not result in the loss of the shutdown function. Jamming of the S1 button will pre-
vent the UE48-2OS from enabling.
Comments
1) Output circuits: These contacts are to be connected to the controller such that, with the output circuit open, the dangerous state
is disabled. For categories 4 and 3, the integration must be dual-channel (x/y paths). Single-channel integration in the control (z
path) is only possible with a single-channel control and by taking the risk analysis into account.
Recommended accessories
Other models and accessories www.sick.com/deTec4_Core_Ex
Brief description
Type
Part no.
Terminal and alignment brackets
2016-07-04 20:20:08 | Online data sheet
Subject to change without notice
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK
5
EXS-09D6403B020, EXE-09D6403B020 | deTec4 Core Ex
SAFETY LIGHT CURTAINS
Brief description
Type
Part no.
A
B
C
D
E
F
2 pieces, alignment bracket for explosion-proof enclosure
BEF-1SHABRST2
2072525
Plug connectors and cables
Cable gland for the European market
Cable gland
5329001
Alignment aids
Laser alignment aid for various sensors, laser class 2 (IEC 60825). Do not look into
the beam!
AR60
1015741
2074849
Adapter AR60 for explosion-proof enclosure
AR60 adapter, Ex
Test and monitoring tools
30 mm diameter
Test rod 30 mm
2022602
H
I
J
K
L
M
N
O
P
Q
R
S
T
6
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK
Online data sheet | 2016-07-04 20:20:08
Subject to change without notice
相关型号:
SI9130DB
5- and 3.3-V Step-Down Synchronous ConvertersWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135LG-T1
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135LG-T1-E3
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135_11
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9136_11
Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130CG-T1-E3
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130LG-T1-E3
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130_11
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137DB
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
©2020 ICPDF网 联系我们和版权申明