1216120 概述
SAFETY LIGHT CURTAINS
1216120 数据手册
通过下载1216120数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载C2C-SA16510A10000, C2C-EA16510A10000
deTec2 Core
SAFETY LIGHT CURTAINS
C2C-SA16510A10000, C2C-EA16510A10000 | deTec2 Core
SAFETY LIGHT CURTAINS
Ordering information
A
B
C
D
E
F
System part
Sender
Type
Part no.
1216123
1216124
C2C-SA16510A10000
C2C-EA16510A10000
Receiver
Other models and accessories www.sick.com/deTec2_Core
Detailed technical data
Features
Sender/receiver pair with QuickFix bracket
System part
H
I
14 mm
Resolution
1,650 mm
Protective field height
Scanning range
Minimum 0 m ... 7 m
Typical 0 m ... 8 m
J
Optical synchronisation
Synchronization
Safety-related parameters
K
L
Type 2 (IEC 61496)
Type
SIL1 (IEC 61508)
SILCL1 (EN 62061)
Safety integrity level
Category 2 (EN ISO 13849)
PL c (EN ISO 13849)
Category
Performance level
M
N
O
P
Q
R
S
T
3.1 x 10-8 (EN ISO 13849)
PFHD (mean probability of a dangerous fail-
ure per hour)
20 years (EN ISO 13849)
TM (mission time)
At least one OSSD is in the OFF state.
Safe state in the event of a fault
Interfaces
System connection
Connection type Male connector M12, 5-pin
Permitted cable length ≤ 50 m
Fieldbus, industrial network
Integration via Flexi Soft safety controller
CANopen, DeviceNet™, EtherCAT®, EtherNet/IP™, Modbus TCP, PROFIBUS DP, PROFINET 1)
1)
For additional information on Flexi Soft -> www.sick.com/Flexi_Soft.
2
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK
Online data sheet | 2017-06-21 19:55:04
Subject to change without notice
C2C-SA16510A10000, C2C-EA16510A10000 | deTec2 Core
SAFETY LIGHT CURTAINS
Electrical data
III (EN 50178)
Protection class
Supply voltage VS
Ripple
24 V DC (19.2 V ... 28.8 V)
1)
≤ 2.4 Vpp
Safety outputs (OSSD)
2 PNP semiconductors, short-circuit protected, cross-circuit monitored 2)
Type of output
Switching voltage HIGH 24 V DC (VS – 2.25 V DC ... VS)
Switching voltage LOW ≤ 2 V DC
Switching current ≤ 300 mA
1)
Within the limits of V .
S
2)
Applies to the voltage range between –30 V and +30 V.
Mechanical data
34 mm x 30.7 mm
Housing cross-section (incl. system connec-
tion)
Aluminum extruded profile
Housing material
Ambient data
Enclosure rating
IP65 (EN 60529)
IP67 (EN 60529)
–30 °C ... +55 °C
Ambient operating temperature
Storage temperature
Air humidity
–30 °C ... +70 °C
15 % ... 95 %, Non-condensing
5 g, 10 Hz ... 55 Hz (EN 60068-2-6)
10 g, 16 ms (EN 60068-2-29)
Vibration resistance
Shock resistance
Other information
Wave length
850 nm
Classifications
27272704
27272704
27272704
27272704
27272704
27272704
27272704
27272704
EC002549
EC002549
46171620
ECl@ss 5.0
ECl@ss 5.1.4
ECl@ss 6.0
ECl@ss 6.2
ECl@ss 7.0
ECl@ss 8.0
ECl@ss 8.1
ECl@ss 9.0
ETIM 5.0
ETIM 6.0
UNSPSC 16.0901
2017-06-21 19:55:04 | Online data sheet
Subject to change without notice
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK
3
C2C-SA16510A10000, C2C-EA16510A10000 | deTec2 Core
SAFETY LIGHT CURTAINS
Dimensional drawing (Dimensions in mm (inch))
A
B
C
D
E
F
30.7
(1.21)
29.5
(1.16)
34
(1.34)
H
I
L=150 (5.91)
1
4
J
12
(0.47)
7
(0.28)
2
5
3
Protective field height
L
K
L
300 (11.81)
450 (17.72)
313 (12.32)
463 (18.23)
600 (23.62)
613 (24.13)
750 (29.53)
763 (30.04)
M
N
O
P
Q
R
S
T
900 (35.43)
913 (35.94)
1,050 (41.34)
1,200 (47.24)
1,350 (53.15)
1,500 (59.06)
1,650 (64.96)
1,800 (70.87)
1,950 (76.77)
2,100 (82.68)
1,063 (41.85)
1,213 (47.76)
1,362 (53.62)
1,512 (59.53)
1,662 (65.43)
1,812 (71.34)
1,962 (77.24)
2,112 (83.15)
4
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK
Online data sheet | 2017-06-21 19:55:04
Subject to change without notice
C2C-SA16510A10000, C2C-EA16510A10000 | deTec2 Core
SAFETY LIGHT CURTAINS
Connection diagram
deTec2 Core safety light curtain connected to UE48-2OS safety relay
24 V DC
1
2
3
4
5
1
2
3
4
5
+24V
n.c.
+24V
OSSD1
GND
GND
n.c.
OSSD2
n.c.
n.c.
S1
S33 S11 S12 S31 A1 13 23 31
k1
k2
UE48-2OS2D2
S34 S35 S21 S22 A2 14 24 32
K1
K2
0 V DC
E114585/01/2014-05-08
Task
Connection of a deTec2 Core safety light curtain to UE48-2OS.
Operating mode: with restart interlock and external device monitoring.
Function
When the light path is clear, the OSSD1 and OSSD2 outputs are live. The system is ready to switch on if K1 and K2 are de-ener-
gized. By pressing S1 (button is pressed and released), the UE48-2OS is energized and its 13 - 14 and 23 - 24 contacts activate K1
and K2. On interruption of one of the light beams, the UE48-2OS is de-energized by the OSSD1 and OSSD2 outputs and K1 and K2
are deactivated.
Fault analysis
OSSD cross-circuits and short-circuits are detected and lead to the inhibited state (lock-out). The incorrect functioning of one of the
K1 or K2 contactors will be detected and does not result in the loss of the shutdown function. Jamming of the S1 button will pre-
vent the UE48-2OS from enabling.
Comments
1) Output circuits: These contacts are to be connected to the controller such that, with the output circuit open, the dangerous state
is disabled. For categories 4 and 3, the integration must be dual-channel (x/y paths). Single-channel integration in the control (z
path) is only possible with a single-channel control and by taking the risk analysis into account.
2017-06-21 19:55:04 | Online data sheet
Subject to change without notice
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK
5
1216120 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
1216121 | SICK | SAFETY LIGHT CURTAINS | 获取价格 | |
1216122 | SICK | SAFETY LIGHT CURTAINS | 获取价格 | |
1216123 | SICK | SAFETY LIGHT CURTAINS | 获取价格 | |
1216124 | SICK | SAFETY LIGHT CURTAINS | 获取价格 | |
1216125 | SICK | SAFETY LIGHT CURTAINS | 获取价格 | |
1216126 | SICK | SAFETY LIGHT CURTAINS | 获取价格 | |
1216127 | SICK | SAFETY LIGHT CURTAINS | 获取价格 | |
1216128 | SICK | SAFETY LIGHT CURTAINS | 获取价格 | |
1216129 | SICK | SAFETY LIGHT CURTAINS | 获取价格 | |
1216130 | SICK | SAFETY LIGHT CURTAINS | 获取价格 |
1216120 相关文章
- 2024-09-20
- 5
- 2024-09-20
- 8
- 2024-09-20
- 8
- 2024-09-20
- 6